ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf
PDF 214 KB Posted
- Attached to
- DLA Fitness Center Renovation Federal contract opportunity
- Solicitation number
- 1430
About this file
This document contains an electrical demolition plan and details for the DLA Fitness Center Renovation project. The plan outlines the scope of electrical work required in Area A of the fitness center, including disconnecting and removing all electrical, telecommunication, and security components back to their sources. Keyed notes specify that circuits feeding certain rooms must remain unaffected and mechanical equipment connections will be disconnected. Telecommunication equipment will be removed by the government. Over 750 fluorescent lamps require removal and disposal according to specification standards. The related federal contract opportunity posting is solicitation number 1430 for the DLA Fitness Center Renovation project issued by the Department of the Army Corps of Engineers Engineering District Norfolk, with a posting date of April 13, 2020.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7
A
B
C
D
E
F
G
H
/A1 ED111B
/A1 ED111B
A
E
D C
A
E
D C
A
E
D D
KEYED NOTES:
1. DISCONNECT AND REMOVE ALL ELECTRICAL, TELECOMMUNICATION, AND SECURITY COMPONENTS (INCLUDING BUT NOT LIMITED TO RECEPTACLES, MECHANICAL EQUIPMENT CONNECTIONS, LUMINAIRES, CABLE TRAYS, TELEPHONE AND DATA OUTLETS, CARD READERS, CATV OUTLETS, PA SPEAKERS, CONDUIT, POWER WIRING, CONTROL WIRING, TELECOMMUNICATION WIRING, AND BOXES) IN THIS SPACE BACK TO SOURCE.
2. NO ELECTRICAL WORK THIS SPACE. CIRCUITS FEEDING THESE ROOMS MUST REMAIN AND NOT BE AFFECTED BY DEMOLITION IN
OTHER AREAS.
3. DISCONNECT AND REMOVE MECHANICAL EQUIPMENT CONNECTIONS. LIGHTING AND RECEPTACLES TO REMAIN.
4. TELECOMMUNICATION EQUIPMENT IN THIS ROOM SHALL BE REMOVED BY GOVERNMENT.
5. EXISTING LIGHTING AND RECEPTACLES TO REMAIN. DISCONNECT AND REMOVE POWER WIRING AND CONDUIT BACK TO SOURCE OF POWER. RECIRCUIT EXISTING LIGHTING AND RECEPTACLES TO NEW PANELBOARD 32FT AND 32GT RESPECTIVELY.
6. REMOVE AND DISPOSE OF 752 FLUORESCENT LAMPS IN ACCORDANCE WITH SPECIFICATION SECTION 02 84 16.
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
ED111A
E L E
C T
R
IC
A L D
E M
O L
IT
IO
N
P L A
N
A R
E A
A S
D
A V
ID
S
O N
R R
U S
S E
L L
W W
E B
B
W W
E B
B
SCALE: 1/8" = 1'-0"
A1
ELECTRICAL DEMOLITION PLAN - AREA A
BAY GBAY F
KEY PLAN
A
4'0 8' 16'
GRAPHIC SCALE
PLAN NORTH
M A
R K
D E
S C
R
IP
T I O
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .