A-111D REFLECTED CEILING PLAN -AREA D.pdf

PDF 237 KB Posted

Attached to
DLA Fitness Center Renovation Federal contract opportunity
Solicitation number
1430
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This reflected ceiling plan drawing depicts proposed renovations to the fitness center at the Defense Supply Center Richmond in Virginia. Key details include installing 4-foot by 8-foot cementitious wood fiber acoustic ceiling panels at existing steel purlins in areas noted, as well as ceiling clouds with mesh and suspended ceiling tiles. Exposed structure will be painted. Large volume fans and other mechanical equipment are shown and shall be coordinated with mechanical and structural drawings. Dimensions and references are provided.

The related federal contract opportunity is a solicitation posted on April 13, 2020 by the Department of the Army Corps of Engineers Engineering District Norfolk. It seeks offers for renovations to the DLA Fitness Center as depicted in the reflected ceiling plan drawing and specified elsewhere. The solicitation number is 1430.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Fitness Center Renovation, newest first.
File Type Posted
H.01.04_Convert B32, Bays F-G for Fitness Center_RTA_Specifications_22Nov19.pdf PDF
Section 09 51 00 Acoustical Ceiling.pdf PDF
118ECE908 RTA FF and E Binder 22Nov19.pdf PDF
Section 09 64 66 Wood Athletic Flooring.pdf PDF
Section 09 30 10 Porcelain Tiling.pdf PDF
Lead Based Paint Survey Report Building No. 32.pdf PDF
Section 12 66 00 Telescoping Stands.pdf PDF
A-111B REFLECTED CEILING PLAN -AREA B.pdf PDF
A-101C FLOOR PLAN -AREA C.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
Section 11 66 23 Gymnasium Equipment.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
Section 09 65 00 Resilient Flooring.pdf PDF
H.01.01_Convert B32, Bays F-G for Fitness Center_RTA_Drawings_22Nov19.pdf PDF
Section 09 65 66 Resiliend Athletic Flooring.pdf PDF
Section 09 68 00 Carpet Tiles.pdf PDF
A-521 MISCELLANEOUS DETAILS.pdf PDF
Section 08 14 00 Wood Doors.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111C ELECTRICAL DEMOLITION PLAN -AREA C.pdf PDF
A-201 BUILDING ELEVATIONS.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
A-111C REFLECTED CEILING PLAN -AREA C.pdf PDF
A-101B FLOOR PLAN -AREA B.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
W91236-20-B-2011 Fitness Center.pdf PDF
A-512 ROOF DETAILS.pdf PDF
A-111A REFLECTED CEILING PLAN -AREA A.pdf PDF
A-121 OVERALL ROOF PLAN.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

E

C

C

C

C

C

C

C

C

C

C

C

C

C

ET ET ET

C

C

C

SS SS

7 8 9 10 11 12 13

H

I

AEROBICS

G105

MARTIAL ARTS

G104

SPINNING

G102

STORAGE

G106

STORAGE

G103

CORRIDOR

G101

VEST.

G100A

RISER ROOM

G100B

12' - 0"

10' - 0"

108108

2' - 3" 12' - 0" 23' - 0" 8' - 0" 22' - 3" 6' - 0" 6' - 8"

REFLECTED CEILING LEGEND

EXIT LIGHT - CEILING

2' x 2' SUSPENDED

ACOUSTIC CEILING TILES

GYPSUM BOARD CEILING

2 X 4 LIGHT FIXTURE

SUSPENDED LIGHT FIXTURE

RETURN AIR GRILLE

SUPPLY AIR GRILLE

EXHAUST AIR GRILLE

CEILING HEIGHT TAG

SD

S

SMOKE DETECTOR

SPEAKER

8'-0"

2' x 2' SUSPENDED

CEILING CLOUD W/MESH

STROBE

WOOD CEILING

4' X 8' CEMENTITIOUS

WOOD FIBER ACOUSTICAL

CEILING PANELS

1 X 4 LIGHT FIXTURE

RECESSED LIGHT FIXTURE

RECESSED DOWN LIGHT

CERAMIC TILE CEILING

CEILING FAN

4X8 T&G CEILING PANEL

A. CENTER CEILING GRID IN ROOM UNLESS SHOWN

OTHERWISE ON REFLECTED CEILING PLAN.

B. CENTER FIXTURES, MECHANICAL DIFFUSERS,

MECHANICAL GRILLES AND SPRINKLER HEADS IN

SUSPENDED ACOUSTICAL CEILING TILE SYSTEM

PANELS.

C. ALL CEILING MOUNTED ITEMS ARE SHOWN FOR

COORDINATION PURPOSES ONLY.

D. SEE ELECTRICAL DRAWINGS FOR LIGHT FIXTURE

AND SPECIAL SYSTEM TYPES.

E. SEE MECHANICAL DRAWINGS FOR DIFFUSER AND

GRILLE TYPES.

F. SEE FIRE PROTECTION FOR SPRINKLER TYPES.

SEE TELECOMMUNICATION AND FIRE PROTECTION

SYSTEMS FOR ADDITIONAL INFORMATION OF

CEILING MOUNTED DEVICES.

G. ALL RCP DIMENSIONS ARE CLEAR FINISHED

DIMENSIONS, UNLESS OTHERWISE NOTED.

H. REFER TO FINISH SCHEDULE FOR CEILING TYPES

AND HEIGHTS NOT INDICATED ON THE REFLECTED

CEILING PLANS.

I. ALL GYPSUM BOARD CEILING WITHIN 4'-0" OF

PERIMETER SHALL BE MOISTURE RESISTANT.

J. SMOKE AND HEAT DETECTORS TO BE GREATER

THAN 3'-0" FROM MECHANICAL DIFFUSERS.

RCP GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

A-111D

R E

F L E

C T

E D

C E

IL

IN

G P

L A

N

A R

E A

D K

.F E

L T

O N

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

SCALE : 1/8" = 1'-0"A1 REFLECTED CEILING PLAN - AREA D

BAY GBAY F

KEY PLAN

D

REFERENCE KEYNOTES:

108 EXPOSED STRUCTURE ABOVE. PAINT ALL EXPOSED

STRUCTURE AND PIPES.

112 BID OPTION: SUSPENDED CEILING CLOUD W/MESH

122 EXISTING CEILING. NO WORK.

123 4'-0" X 8'-0" CEMENTITIOUS WOOD FIBER

ACOUSTICAL CEILING PANELS ATTACHED AT

EXISTING STEEL PURLINS. SEE DETAIL C1/A-511

147 LARGE VOLUME FANS. SEE MECHANICAL DWGS.

AND STRUCTURAL DWGS.

0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

-2

-2

File details come from the government source that posted it. Updated .