A-121 OVERALL ROOF PLAN.pdf
PDF 163 KB Posted
- Attached to
- DLA Fitness Center Renovation Federal contract opportunity
- Solicitation number
- 1430
About this file
This document includes an overall roof plan drawing and details for a solicitation to renovate the fitness center at the Defense Supply Center Richmond in Virginia. The Army Corps of Engineers Norfolk District is seeking bids to patch and replace portions of the existing EPDM roofing membrane and decking at removed mechanical equipment locations. The project also includes adding new rooftop mechanical units and associated equipment curbs and plumbing penetrations. Bidders should reference the mechanical drawings and roof detail drawings for specifications on new equipment requirements. The solicitation number is 1430 and was posted on April 13, 2020 for the Department of the Army Corps of Engineers Norfolk District. The deadline to respond has not been provided.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C1
A-301
D1
A-301
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G
H
I
J
A1
A-301
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
EXISTING
DS
RIDGERIDGE
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
+/- 120' - 0" +/- 120' - 0"
+/- 240' - 0"
EDGE OF WALL BELOW
EDGE OF WALL BELOW
140140
143140140
140140
144144
143143
146146146146
A2
A-312
A4
A-312
A1
A-312 A-201
A1
A-201 D1
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
A-121
O V
E R
A L L R
O O
F P
L A
N K
.F E
L T
O N
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
SCALE : 1/16" = 1'-0"A1 OVERALL ROOF PLAN
BAY GBAY F
KEY PLAN
A C
B D0 8' 16' 32'
GRAPHIC SCALE
PLAN NORTH
REFERENCE KEYNOTES:
140 EXISTING EPDM ROOFING
141 EXISTING FIREWALL CAP AND EXPANSION JOINT
142 NEW ROOFTOP MECHANICAL UNIT, REFER TO
MECHANICAL DWGS. AND A3/A-512 FOR
EQUIPMENT CURB REQUIREMENTS
143 NEW PLUMBING PENETRATION, SEE PLUMBING
DWGS AND ROOF DETAIL B5/A-512
144 EXISTING EXPANSION JOINT
145 EXISTING ROOF ACCESS LADDER
146 PATCH EPDM ROOFING MEMBRANE AND DECKING
AT REMOVED MECHANICAL EQUIPMENT
LOCATIONS. MATCH EXISTING CONSTRUCTION,
SEE DETAIL B3/A-512
156 NEW ROOFTOP MECHANICAL UNIT, REFER TO
MECHANICAL DWGS. AND A5/A-512 FOR
EQUIPMENT CURB REQUIREMENTS
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2
File details come from the government source that posted it. Updated .