A-121 OVERALL ROOF PLAN.pdf

PDF 163 KB Posted

Attached to
DLA Fitness Center Renovation Federal contract opportunity
Solicitation number
1430
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document includes an overall roof plan drawing and details for a solicitation to renovate the fitness center at the Defense Supply Center Richmond in Virginia. The Army Corps of Engineers Norfolk District is seeking bids to patch and replace portions of the existing EPDM roofing membrane and decking at removed mechanical equipment locations. The project also includes adding new rooftop mechanical units and associated equipment curbs and plumbing penetrations. Bidders should reference the mechanical drawings and roof detail drawings for specifications on new equipment requirements. The solicitation number is 1430 and was posted on April 13, 2020 for the Department of the Army Corps of Engineers Norfolk District. The deadline to respond has not been provided.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Fitness Center Renovation, newest first.
File Type Posted
A-521 MISCELLANEOUS DETAILS.pdf PDF
Section 08 14 00 Wood Doors.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111C ELECTRICAL DEMOLITION PLAN -AREA C.pdf PDF
A-111D REFLECTED CEILING PLAN -AREA D.pdf PDF
A-201 BUILDING ELEVATIONS.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
A-111C REFLECTED CEILING PLAN -AREA C.pdf PDF
A-101B FLOOR PLAN -AREA B.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
W91236-20-B-2011 Fitness Center.pdf PDF
A-512 ROOF DETAILS.pdf PDF
A-111A REFLECTED CEILING PLAN -AREA A.pdf PDF
H.01.04_Convert B32, Bays F-G for Fitness Center_RTA_Specifications_22Nov19.pdf PDF
Section 09 51 00 Acoustical Ceiling.pdf PDF
118ECE908 RTA FF and E Binder 22Nov19.pdf PDF
Section 09 64 66 Wood Athletic Flooring.pdf PDF
Section 09 30 10 Porcelain Tiling.pdf PDF
Lead Based Paint Survey Report Building No. 32.pdf PDF
Section 12 66 00 Telescoping Stands.pdf PDF
A-111B REFLECTED CEILING PLAN -AREA B.pdf PDF
A-101C FLOOR PLAN -AREA C.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
Section 11 66 23 Gymnasium Equipment.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
Section 09 65 00 Resilient Flooring.pdf PDF
H.01.01_Convert B32, Bays F-G for Fitness Center_RTA_Drawings_22Nov19.pdf PDF
Section 09 65 66 Resiliend Athletic Flooring.pdf PDF
Section 09 68 00 Carpet Tiles.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

C1

A-301

D1

A-301

1 2 3 4 5 6 7 8 9 10 11 12 13

A

B

C

D

E

F

G

H

I

J

A1

A-301

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

EXISTING

DS

RIDGERIDGE

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

+/- 120' - 0" +/- 120' - 0"

+/- 240' - 0"

EDGE OF WALL BELOW

EDGE OF WALL BELOW

140140

143140140

140140

144144

143143

146146146146

A2

A-312

A4

A-312

A1

A-312 A-201

A1

A-201 D1

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

A-121

O V

E R

A L L R

O O

F P

L A

N K

.F E

L T

O N

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

H .A

B D

E L A

Z

IZ

SCALE : 1/16" = 1'-0"A1 OVERALL ROOF PLAN

BAY GBAY F

KEY PLAN

A C

B D0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

REFERENCE KEYNOTES:

140 EXISTING EPDM ROOFING

141 EXISTING FIREWALL CAP AND EXPANSION JOINT

142 NEW ROOFTOP MECHANICAL UNIT, REFER TO

MECHANICAL DWGS. AND A3/A-512 FOR

EQUIPMENT CURB REQUIREMENTS

143 NEW PLUMBING PENETRATION, SEE PLUMBING

DWGS AND ROOF DETAIL B5/A-512

144 EXISTING EXPANSION JOINT

145 EXISTING ROOF ACCESS LADDER

146 PATCH EPDM ROOFING MEMBRANE AND DECKING

AT REMOVED MECHANICAL EQUIPMENT

LOCATIONS. MATCH EXISTING CONSTRUCTION,

SEE DETAIL B3/A-512

156 NEW ROOFTOP MECHANICAL UNIT, REFER TO

MECHANICAL DWGS. AND A5/A-512 FOR

EQUIPMENT CURB REQUIREMENTS

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

A

M E

N D

M E

N T

-2

-2

File details come from the government source that posted it. Updated .