This floor plan drawing depicts proposed renovations to the Defense Supply Center Richmond Fitness Center located at Building 32, Bays F and G. Key details include:
-
The renovations will upgrade and expand the existing 7,010 square foot gymnasium area to include new vinyl-covered athletic wall pads, scoreboard, retractable bleachers, floor markings for basketball and volleyball courts, gym divider curtain, and other athletic equipment. Support spaces such as locker rooms, training areas, and mechanical and storage rooms will also be updated.
-
The related federal contract opportunity is solicitation number 1430 issued by the Department of the Army Corps of Engineers Norfolk District to renovate the fitness center. Responses were due on April 13, 2020. The solicitation seeks contractors to perform the renovations depicted in the floor plan drawing and bring the facility up to current standards for military fitness centers.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C1
A-301
C1
A-301
7 8 9 10 11 12 13
A
B
C
D
E
F
G
A-412
C1
A4
A1
C4
A1
A-301
A1
A-301
1779 SF
EXISTING BOILER
ROOM
G113
110 SF
EXISTING
TELECOM
G110
440 SF
EXISTING
MECHANICAL
G108
113 SF
EXISTING
ELECTRICAL
G107
632 SF
STORAGE
G106
7010 SF
GYMNASIUM
G111
260 SF
WOMEN
G116
262 SF
MEN
G118
42 SF
JAN.
G117
698 SF
THERAPY AREA
G121
141 SF
STORAGE
G119
233 SF
RELAXATION
ROOM
G123
118 SF
PERSONAL
TRAINER
G124
230 SF
RELAXATION
ROOM
G122
140 SF
STORAGE
G120
799 SF
MECHANICAL
G114
1751 SF
CORRIDOR
G112
1181 SF
CORRIDOR
G101
101 SF
VESTIBULE
G115
170 SF
CORR.
G121A
187 SF
STORAGE
G109
45 SF
EXISTING RISER
ROOM
G125
G113A
G113B
G108A
G108B
G107
G115A
G115B
G110
G112B
G127
G C
G D
G
G
G 7 G
G
G B
G112A
G B
G109
G A
G114
G125 G126A
G126B
28 SF
MECH
G127
104' - 2" +/- 15' - 5 3/4"
P2B
P2B
P4
P2BP2B
P6
P6
P6
P6
P2B
P2D
P1
16' - 5" 63' - 9" 39' - 2"
/2
118118
G A
G
DN
P2
125125125
A-501
A5
P2D
P2D
P2D
A-501
D4
A-501
D5
W1
P1B
+/- 38' - 5 3/8" 22' - 1" 8' - 6" 21' - 1"
9' - 8" 6' - 10" 12' - 5"
DN
DN
DN
DN
DN
DN
DN
118118
A-401
D5
G123
G122
G124
148A-501
D4
A-501
D5
1' - 9"
5' - 6"
11' - 3" 8' - 6"
11' - 4"
A1
A-312
P6
P1B
P1B
P1B
4' - 9" 7' - 0" 4' - 8"
DN
P2B
P2B
P2B
P2B
A.
B.
C.
D.
E.
REFER TO SHEET A-002 FOR PARTITION TYPES
AND TYPICAL DETAILS.
ALL DIMENSIONS ARE FACE OF MASONRY OR FACE
OF METAL STUD.
PAINT ALL EXPOSED STEEL STRUCTURE.
PROVIDE WALL REINFORCING AT ALL WALL HUNG
CASEWORK, FIXTURES, SPECIALTY EQUIPMENT,
BALLET BARRE, MARKER/DISPLAY BOARDS AND
SHELVES, REFER TO TYPICAL PARTITION DETAILS,
BACKING PLATE DETAILS.
ALL INTERIOR DOORS SHALL HAVE HINGE SIDE
DIMENSION FROM INTERSECTING PARTITION TO
DOOR FRAME EDGE OF 4" AT GYPSUM
PARTITIONS, TYP. U.N.O
US Army Corps of Engineers ®
SHEET
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
N O
R F
O L K
D
IS
T
R
IC
T N
O R
F O
L K
V
IR
G
IN
IA
READY TO ADVERTISE
D E
F E
N S
E S
U P
P L Y
C E
N T
E R
R
IC
H M
O N
D
D S
C R
V
IR
G
IN
IA
C O
N V
E R
T B
B
A Y
S F
G
F
IT
N
E S
S C
E N
T E
R P
R O
J E
C T
E
C E
N O
V E
M B
E R
W -1
-R
-0
W -1
-R
-0
A-101C
F L O
O R
P L A
N
A R
E A
C K
.F E
L T
O N
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
H .A
B D
E L A
Z
IZ
BAY GBAY F
KEY PLAN
C
4'0 8' 16'
GRAPHIC SCALE
PLAN NORTH
REFERENCE KEYNOTES:
GENERAL NOTES:
101 ELECTRIC WATER COOLER
102 MECHANICAL EQUIPMENT. SEE MECHANICAL
DWGS
110 BID OPTION: 4-TIERED RETRACTABLE BLEACHERS
111 COURT MARKINGS, SEE INTERIOR SHEETS I-401
AND I-402
113 VINYL COVERED ATHLETIC WALL PADS, MOUNTED
TO WALL W/ TOP @ 8'-6". SEE INTERIOR
ELEVATIONS AND DETAIL C5/A-521. SEE
ELECTRICAL DWGS FOR COORDINATION OF
CUT-OUT INSERTS
116 MOUNTED SCOREBOARD, N.I.C.
118 EXISTING WINDOW TO REMAIN
121 VINYL COVERED ATHLETIC COLUMN WRAP PADS
125 3 1/2" DIA. SLEEVE (FOR VOLLEYBALL POST) W/
REMOVABLE COVER PLATE. SEE DETAIL B5/A-521
126 ROLL UP GYM DIVIDER CURTAIN. SEE DETAIL
C1/A-521
128 TRANSITION RAMP FLOORING, SEE INTERIOR
DETAILS.
129 BRACKET MOUNTED FIRE EXTINGUISHER
130 SEMI RECESSED FIRE EXTINGUISHER CABINET,
SEE DETAIL D4/A-521
132 48" x 48" MARKER BOARD. SEE INTERIOR DWGS.
135 NEW 2'-0"X 2'-0" MECHANICAL LOUVER, 10'-0" A.F.F.
138 ENCLOSED BULLETIN BOARD. SEE INTERIOR
DWGS.
148 ALIGN FACE OF WALL FINISH TO EXISTING
149 INFILL EXISTING OPENING W/ 4" CMU BACKER AND
SALVAGED BRICK TO MATCH EXISTING.
153 PATCH/REPAIR MTL. STUD FURRING AND GYP. BD.
AROUND COLUMNS AS NECESSARY, TYP.
SCALE : 1/8" = 1'-0"A1 FLOOR PLAN - AREA C
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
-2
-2