118ECE908 RTA FF and E Binder 22Nov19.pdf

PDF 8 MB Posted

Attached to
DLA Fitness Center Renovation Federal contract opportunity
Solicitation number
1430
Issued by
Department of the Army Corps of Engineers Engineering District Norfolk

About this file

This document package provides specifications for furniture, fixtures, and equipment (FF&E) for the Defense Supply Center Richmond Fitness Center renovation project. The package includes a design narrative, point of contact list, item code index, FF&E order data sheets specifying products, color and material samples, and drawings showing overall and enlarged furniture plans, electrical plans, and telecommunications plans. Key products required include seating, desks, storage units, tables, and fitness equipment. The Army Corps of Engineers is the contracting agency and Woolpert-RS&H JV LLC prepared the specifications package. The solicitation number for the related federal contract opportunity is 1430.

View the file

Other files for this federal contract opportunity

Other files attached to DLA Fitness Center Renovation, newest first.
File Type Posted
H.01.04_Convert B32, Bays F-G for Fitness Center_RTA_Specifications_22Nov19.pdf PDF
Section 09 51 00 Acoustical Ceiling.pdf PDF
Section 09 64 66 Wood Athletic Flooring.pdf PDF
Section 09 30 10 Porcelain Tiling.pdf PDF
Lead Based Paint Survey Report Building No. 32.pdf PDF
Section 12 66 00 Telescoping Stands.pdf PDF
A-111B REFLECTED CEILING PLAN -AREA B.pdf PDF
A-101C FLOOR PLAN -AREA C.pdf PDF
118ECE908_RTA_SID Binder_22Nov19.pdf PDF
M-503 MECHANICAL DETAILS.pdf PDF
Section 11 66 23 Gymnasium Equipment.pdf PDF
ED111B ELECTRICAL DEMOLITION PLAN -AREA B.pdf PDF
Section 09 65 00 Resilient Flooring.pdf PDF
H.01.01_Convert B32, Bays F-G for Fitness Center_RTA_Drawings_22Nov19.pdf PDF
Section 09 65 66 Resiliend Athletic Flooring.pdf PDF
Section 09 68 00 Carpet Tiles.pdf PDF
A-521 MISCELLANEOUS DETAILS.pdf PDF
Section 08 14 00 Wood Doors.pdf PDF
I101C FLOOR FINISH PLAN -AREA C.pdf PDF
ED111A ELECTRICAL DEMOLITION PLAN -AREA A.pdf PDF
Asbestos Re-Inspection Report DSCR Building No. 32.pdf PDF
ED111C ELECTRICAL DEMOLITION PLAN -AREA C.pdf PDF
A-111D REFLECTED CEILING PLAN -AREA D.pdf PDF
A-201 BUILDING ELEVATIONS.pdf PDF
ED111D ELECTRICAL DEMOLITION PLAN -AREA D.pdf PDF
A-111C REFLECTED CEILING PLAN -AREA C.pdf PDF
A-101B FLOOR PLAN -AREA B.pdf PDF
I101D FLOOR FINISH PLAN -AREA D.pdf PDF
W91236-20-B-2011 Fitness Center.pdf PDF
A-512 ROOF DETAILS.pdf PDF
A-111A REFLECTED CEILING PLAN -AREA A.pdf PDF
A-121 OVERALL ROOF PLAN.pdf PDF
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Woolpert-RS&H JV LLC 4454 Idea Center Blvd Dayton, Ohio 45430

READY TO ADVERTISE (RTA)

FURNITURE, FIXTURES & EQUIPMENT (FF&E)

DEFENSE SUPPLY CENTER RICHMOND (DSCR)

RICHMOND, VIRGINIA

CONVERT B32, BAYS F & G – FITNESS CENTER

22 NOVEMBER 2019

RICHMOND, VIRGINIA

CONVERT B32, BAYS F&G - FITNESS CENTER

FURNITURE, FIXTURES AND EQUIPMENT

(FF&E)

TABLE OF CONTENTS

TAB 1- NARRATIVE OF FF&E DESIGN OBJECTIVES

TAB 2- POINTS OF CONTACT (POC) LIST

TAB 3- ITEM CODE INDEX

TAB 4- FF&E ORDER DATA SHEETS (FURNITURE SPEC)

TAB 5- COLOR/SAMPLE BOARDS

TAB 6- DRAWINGS:

1. OVERALL FURNITURE PLAN

2. ENLARGED FURNITURE PLANS A - D

3. ELECTRICAL AND TELECOMMUNUCATION PLANS

SECTION 01

NARRATIVE OF FF&E DESIGN OBJECTIVES

Brooke Foret Rectangle

Defense Supply Center Richmond (DSCR), Virginia Convert B32, Bays F&G – Fitness Center

CONVERT B32, BAYS F&G – FITNESS CENTER

READY TO ADVERTISE (RTA)

INTERIOR DESIGN NARRATIVE

1. DESIGN STANDARDS

• Department of Defense Unified Facilities Criteria (UFC)

• UFC 3-120-10 Interior Design, with Change 1 (July 2007)

• International Building Code (IBC), 2015 Edition

• UFC 1-200-01, General Building Requirements, 20 June 2016

• United Facilities Guide Specifications (UFGS)

• ABA Architectural Barriers Act 1968

• ADA Accessibility Guidelines (ADAAG) 2010

2. GENERAL PARAMETERS

1. The interior design shall be integrated as part of the project’s design scope conveying the user’s functional and aesthetic requirements while preserving some of the historic existing interior architectural materials.

2. Spaces are designed for multi-functional uses to maximize flexibility as fitness trends and requirements change.

3. INTERIOR FINISHES

Quality materials appropriate to the design of a fitness center are being provided to support the environment which will include, cardio/circuit training areas, aerobic/spinning rooms, fitness areas, weight rooms, a gymnasium, racquetball courts, administrative offices, therapy spaces and storage areas. Overall, the interior finishes must be very durable and conducive to the fitness center’s overall, multifaceted functionality. Currently, the fitness center uses a modern, industrial design for all their marketing materials and the user’s want to incorporate this as the scheme for the facility’s interior design. This scheme includes red, gray, black and white colors which have been incorporated throughout the facility’s design. An open floor plan with minimal walls has been incorporated into the design, per the user representatives request. Storage locations are imperative to the function of the facility and are incorporated not the facility as directed by the user’s representative.

The flooring finishes selected throughout the facility, are provided to support the safety and durability of the center. The two existing bay’s slab has a high moisture content and no vapor barrier. Flooring finishes have been specified with underlayment to address the existing slab’s high moisture content.

The restrooms including showers, sauna rooms, steam rooms and locker areas will have a new slab and vapor barrier, so flooring doesn’t require the same level of protection as the existing slab.

Heavy fitness equipment will constantly be hauled across the floors in the cardio, circuit and weight areas. As per user request, refinished, polished concrete floors are specified for all main corridors.

Interior materials by area:

a. The Cardio/Circuit Area has been specified with a durable athletic rubber, interlocking tile flooring and a rubber base. Acoustical ceiling panels have been specified for the deck.

b. The Aerobics Room includes a Ballet/balance bar, wall mirrors, and wood floors with vented rubber base.

c. The Free Weight Area has been specified with athletic rubber, interlocking tile flooring and a rubber base. Acoustical ceiling panels have been specified for the deck.

d. The Gymnasium requires athletic wood floors with regulation markings. The user requested the

“Red Brick logo” be incorporated at the center of the basketball court. This image will be provided by user. Acoustical wall panels have been specified in the gym along with acoustical ceiling panels.

e. The Racquetball court requires wood floors with regulation markings. Walls and ceilings are specified with white, high impact prefab panels for this type of court. A floor base is not required.

f. The Functional Fitness Area has been specified with Turf flooring. The users provided the basis of design for this space. Acoustical ceiling panels have been specified for the deck.

g. The Martial Arts Room will have durable athletic rubber, interlocking tile flooring and a rubber base.

h. The Wellness Areas require dimmable lighting. This space includes 2 Relaxation Rooms which have resilient LVT flooring and a rubber base. This area also includes the Therapy Room and Personal Trainer’s office. Both spaces have been specified with resilient LVT flooring and a rubber base.

i. The Administrative Area has been specified with closed cell, cushioned back carpet tiles and a rubber base. The Basis of Design manufacturer is Milliken.

j. The Director’s Office has been specified with closed cell, cushioned back carpet tiles and a rubber base. The Basis of Design manufacturer is Milliken.

k. The Staff Break Room has been specified with resilient flooring and a rubber base.

l. The Restrooms and Locker areas are specified with epoxy flooring and base. Stalls and urinal screens are specified with HDPE solid plastic. Walls are full height porcelain tiles with two accent bands. The Sauna is specified with red cedar throughout and the Steam Room is specified with porcelain tile floors, walls, bench and ceiling.

m. All Storage Rooms will have sealed concrete floors with rubber base.

n. The Laundry Room has been specified with resilient floors with rubber base.

Wall finishes and ceiling materials are specific to the functionality of each room or area. Careful attention has been made to the acoustics of each space and the overall sound quality of the fitness center.

4. FURNITURE, FIXTURES & EQUIPMENT

1. Furniture layouts have been developed to make the most efficient use of floor space and provide flexible environments for all user groups and their work functions.

2. The main areas receiving furnishings are the administrative areas. Sit-to-stand desks are provided in admin and trainer areas. These desks include standard file/box drawers for storage at workstations. The Control Desk area has 4 stations for the support staff. The Director’s Office has 1 laminate, sit-to-stand L-shaped desk, guest seating, a task chair and a storage tower.

3. A small storage closet has been provided by the front desk. This space includes shelving for ancillary equipment items that will be dispersed by the staff to members.

4. Relaxation rooms will have GFGI massage chairs and accent casegoods.

5. The personal trainer office, located in the therapy area, includes an L-shaped metal desk, task chair, guest chair and storage.

6. The storage room includes wall to wall industrial storage shelving.

7. All fitness equipment is GFGI. The final layout and equipment will be developed and purchased, at a later date, by users.

SECTION 02

POINT OF CONTACT (POC) LIST

CLARIDGE PRODUCTS & EQUIPMENT, INC.

601 Highway 62-65 South (72601) GSA Contract Number: GS-28F-0042U

Harrison, AR 72602 Expiration Date: 04-12-20 www.claridgeproducts.com FSC Group: 71

(p) 870-743-2200 SIN 711.20

NEWELL RUBBERMAID, INC

3124 Valley Avenue GSA Contract Number: GS-06F-0032K

Winchester, VA 22602 Expiration Date: 06-30-20

800-347-9800 FSC Group: 51V www.rubbermaid.com SIN 105 002

ULINE

12575 Uline Drive GSA Contract Number:

Pleasant Prairie, WI 53158 Expiration Date:

Tel: 800-295-5510 FSC Group:

www.uline.com SIN

STEELCASE

901 44th Street, SE GSA Contract Number: GS-27F-0014V

CH-2W-08 Expiration Date: 04-12-20

Grand Rapids, MI 49508 FSC Group: 71

913-221-3460 SIN 711.18

www.steelcase.com

LYON WORKSPACE PRODUCTS

PO Box 671 GSA Contract Number: GS-27F-035DA

Aurora, IL 60507-0671 Expiration Date: 04-12-2020 www.lyonworkspace.com FSC Group: 71

(p) 800-433-8488 SIN 71.31

POINT OF CONTACTS LIST

The following is a list of the manufacturers specified as Basis of Design for the FF&E

Package

SECTION 03

ITEM CODE INDEX

SECTION 04

FF&E ORDER DATA SHEETS (FURNITURE SPEC)

SECTION 05

COLOR / SAMPLE BOARDS

Woolpert-RS&H LLC 4454 Idea Center Boulevard

Dayton, OH 45430-1500

CONVERT B32, BAYS F&G

FITNESS CENTER

DEFENSE SUPPLY CENTER RICHMOND

(DSCR), VIRGINIA

FURNITURE FINISHES

Upholstery Manufacturer: Steelcase Style: Mesh Color: Licorice Location: C1

Upholstery Manufacturer: Designtex Style: Connor Color: Gray Location: C1

Plastic Finish Manufacturer: Steelcase Color: Platinum Solid 6249 Location: C1 & C2

Upholstery Manufacturer: Steelcase Style: Stand In Color: Lava Location: C2

Dayton, OH 45430-1500

CONVERT B32, BAYS F&G

FITNESS CENTER

DEFENSE SUPPLY CENTER RICHMOND

(DSCR), VIRGINIA

FURNITURE FINISHES

Plastic Finish Manufacturer: Steelcase Color: Arctic White 6009 Location: C3

Upholstery Manufacturer: Designtex Style: Treeline Color: Slate Location: C3

Wood Veneer Manufacturer: Steelcase Color / Style: Natural Walnut Location: S4

Dayton, OH 45430-1500

CONVERT B32, BAYS F&G

FITNESS CENTER

DEFENSE SUPPLY CENTER RICHMOND

(DSCR), VIRGINIA

FURNITURE FINISHES

Painted Metal Finish Manufacturer: Steelcase Color / Style: Platinum Metallic 4799 Location: D1, D2, T1

High Pressure Laminate Manufacturer: Steelcase Color / Style: Virginia Walnut Location: D1, D2, S3

High Pressure Laminate Manufacturer: Steelcase Color / Style: Arctic White 2730 Location: T1

Dayton, OH 45430-1500

CONVERT B32, BAYS F&G

FITNESS CENTER

DEFENSE SUPPLY CENTER RICHMOND

(DSCR), VIRGINIA

FURNITURE FINISHES

High Pressure Laminate Manufacturer: Steelcase Color / Style: Gypsum Micro 2921 Location: WS1

Painted Metal Finish Manufacturer: Steelcase Color / Style: Fieldstone 7238 Location: WS1

Tackable Surface Manufacturer: Steelcase Style: Alloy Color: Shore Location: WS1, D1, D2

Tackable Surface Manufacturer: Steelcase Style: Alloy Color: Construct Location: WS1

SECTION 06

DRAWINGS

OVERALL FURNITURE PLAN

ENLARGED FURNITURE PLANS A - D

ELECTRICAL AND TELECOMMUNUCATION PLAN

Rectangle

Brooke Foret Text Box

ELECTRICAL POWER PLANS

TELECOMMUNICATION PLANS

G3

EXISTING MECHANICAL

F108

EXISTING ELECTRICAL

F107

EXISTING BOILER

ROOM

G113

EXISTING TELECOM

F117

EXISTING TELECOM

G110

EXISTING MECHANICAL

G108

EXISTING ELECTRICAL

G107

EXISTING RISER ROOM

F103

RACQUETBALL COURT

F114

PROGRAM DIR.

F104

BREAK

F106

STORAGE

F109

FUNCTIONAL FITNESS

F113

CIRCUIT

F112

CARDIO

F111

WEIGHT

F110

AEROBICS

G105

MARTIAL ARTS

G104SPINNING

G102

STORAGE

G106

GYMNASIUM

G111

STORAGE

G103

WOMEN

G116

MEN

G118

JAN.

G117

THERAPY AREA

G121

STORAGE

G119

RELAXATION ROOM

G123

PERSONAL TRAINER

G124

RELAXATION ROOM

G122

STORAGE

G120

MECHANICAL

G114

CORRIDOR

G112

JANITOR

F118

LAUNDRY

F119

BREEZEWAY

F100

STORAGE/ EQUIP.

F105

CONTROL DESK/

SUPPORT STAFF

F102

VIEWING AREA

F114A

CORRIDOR

G101

CORRIDOR

F109A

VESTIBULE

G115

CORR.

G121A

CORRIDOR

F107A

SAUNA

F116B

WOMEN LOCKER

F116C

MEN LOCKER

F115C

STEAM

F116D

MECH.

F116E

MECH.

F115E

STEAM

F115D

SAUNA

F115B

CORRIDOR

F101A

STORAGE

G109

ENTRY/ LOBBY

F101

EXISTING RISER ROOM

F103A

EXISTING RISER ROOM

G126

EXISTING RISER ROOM

G125

CORRIDOR

F101B

VEST.

G100A

RISER ROOM

G100B

MECH

G127

MECH

G128

MEN RESTROOM

F115A

WOMEN RESTROOM

F116A

MEN SHOWERS

F115F

WOMEN SHOWERS

F116F

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O L K

D

IS

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

E R

W -1

-R

-0

W -1

-R

-0

IF101

F U

R N

IT

U

R E

P L A

N

O V

E R

A L L

K .B

A R

K E

R

L .P

H

IL

L

IP

S

B .F

O R

E T

B .F

O R

E T

SCALE: N.T.S.

A1

FURNITURE PLAN - OVERALL 0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

BAY GBAY F

KEY PLAN

A C

B D

M A

R K

D E

S C

R

IP

T I O

N D

A T

E

C1 C1

C1 C1

WS-1

G2

A3

A3

D1

C2

C2C1

A3

A3

A3

A3

C3

T1

A1

M A

T C

H

LI

N E

S E

E A

1/

IF

1C

EXISTING MECHANICAL

F108

EXISTING ELECTRICAL

F107

EXISTING RISER ROOM

F103

RACQUETBALL COURT

F114

PROGRAM DIR.

F104

BREAK

F106

STORAGE

F109

FUNCTIONAL FITNESS

F113

CIRCUIT

F112

CARDIO

F111

WEIGHT

F110

BREEZEWAY

F100

STORAGE/ EQUIP.

F105

CONTROL DESK/

SUPPORT STAFF

F102

VIEWING AREA

F114A

CORRIDOR

F109A

CORRIDOR

F107A

CORRIDOR

F101A

ENTRY/ LOBBY

F101

EXISTING RISER ROOM

F103A

A5 A4

A6

A2

A2

A2

A2

A2

A2

MATCHLINE

SEE A1/IF111B

S3

S1

C3

C3C3

A1

A3 A3

A7

A7

G5 NOTE:

ALL FITNESS EQUIPMENT IS GFGI. LAYOUT IS

CONCEPTUAL AND WILL BE PROVIDED BY

USER REPRESENTATIVE AT A FUTURE DATE.

G4

G3

S1

S1

S1 S1 S1

S1 S1 S1

1. FURNITURE, FIXTURE AND EQUIPMENT PLANS ARE PROVIDED FOR

REFERENCE ONLY.

2. FURNITURE, FIXTURES & EQUIPMENT (FF&E) IS NOT IN BASE CONTRACT AND

SHALL BE PROCURED AS PART OF A SEPARATE CONTRACT LINE ITEM TO

THE BASE BID.

3. REFER TO THE PROJECT'S COMPREHENSIVE INTERIOR DESIGN (CID)

PACKAGE FOR ADDITIONAL FURNITURE DETAILS AND SPECIFICATIONS.

4. POWER AND DATA CONNECTIONS ARE TO BE MADE BY THE CONTRACTOR.

5. FIELD VERIFY ALL MEASUREMENTS AND SITE CONDITIONS PRIOR TO ORDER

ENTRY TO ENSURE PROPER FIT OF ALL FF&E ITEMS. FURNISHINGS SHALL

NOT OVERLAP OR OBSTRUCT DOORWAYS, WALL SWITCHES, THERMOSTATS

OR OTHER WALL MOUNTED ITEMS. MODIFICATIONS TO FURNITURE

LAYOUTS, REQUIRED TO MEET BUILDING CONDITIONS AT THE TIME OF

INSTALLATION, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL

MODIFICATIONS MUST BE APPROVED IN WRITING BY A GOVERNMENT

APPROVED REPRESENTATIVE PRIOR TO FF&E INSTALLATION.

6. REFER TO MEP PLANS TO COORDINATE LIGHT SWITCHES, THERMOSTATS,

DIFFUSERS AND ACCESS PANELS WITH FURNITURE LAYOUTS.

CONTRACTOR SHALL IDENTIFY ANY CONFLICTS WITH FURNITURE LAYOUTS.

AUDIO VISUAL EQUIPMENT AND FURNITURE SHALL BE FUNDED UNDER

SEPARATE CONTRACT. PROVIDE ALL CONDUIT AND POWER FOR THE AV

SYSTEMS.

7. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED FURNITURE,

MARKERBOARDS, TACKBOARDS, AND STORAGE UNITS .

8. GOVERNMENT FURNISHED, GOVERNMENT INSTALLED (GFGI) ITEMS ARE

NOT INCLUDED IN THE FF&E PACKAGE AND WILL BE SHOWN FOR

COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE PRINTERS,

COPIERS, SHREDDERS, REFRIGERATORS, MICROWAVES, FITNESS

EQUIPMENT AND VENDING MACHINES AS INDICATED.

9. A2 WALL CLOCKS TO BE INSTALLED AT 7'-0" A.F.F.

FURNITURE GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

IF111A

F U

R N

IT

U

R E

P L A

N

A R

E A

A K

.B A

R K

E R

L .P

H

IL

L

IP

S

B .F

O R

E T

B .F

O R

E T

BAY GBAY F

KEY PLAN

A

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

SCALE: 1/8" = 1'-0"

A1

FURNITURE PLAN - AREA A

FURNITURE LEGEND

CODE PRODUCT DESCRIPTION QTY.

01 ACCESSORIES

A1 48 X 48 MARKER BOARD 3

A2 WALL CLOCK 14

A3 7 GAL. TRASH CAN 15

A4 RECYCLE STATION 1

A5 BULLETIN BOARD 5

A6 TRASH CAN WITH WHEELS & LID 2

A7 SLIM WASTEBASKET, 23 GAL. 2

02 SEATING

C1 TASK CHAIR 6

C2 GUEST CHAIR 3

C3 BREAK ROOM CHAIR 4

03 DESKS

D1 LAMINATE "L" SHAPE HGT. ADJ. DESK 1

D2 METAL "L" SHAPE W/ HGT. ADJ. DESK 1

04 STORAGE

S1 36"W OPEN SHELVING 9

S2 48"W OPEN SHELVING 46

S3 WARDROBE TOWER, LEFT HINGE 1

S4 STORAGE CREDENZA 2

05 TABLES

T1 BREAK ROOM TABLE, 36W 1

06 WORKSTATIONS

WS-1 4 PACK "L" SHAPE WORKSTATIONS 1

GFGI

G1 MASSAGE CHAIR 4

G2 PRINTER/COPIER 1

G3 REFRIGERATOR 1

G4 MICROWAVE 1

G5 FITNESS EQUIPMENT ITEMS 1

G6 DRYER 1

G7 WASHER 1

GFGI

NOTE:

FITNESS EQUIPMENT ITEMS (G5), QUANTITIES AND EQUIPMENT LAYOUT WILL BE PROVIDED BY

USER.

M A

R K

D E

S C

R

IP

T I O

N D

A T

EXISTING TELECOM

F117

JANITOR

F118

LAUNDRY

F119

SAUNA

F116B

WOMEN LOCKER

F116C

MEN LOCKER

F115C

STEAM

F116D

MECH.

F116E

MECH.

F115E

STEAM

F115D

SAUNA

F115B

CORRIDOR

F101B

MATCHLINE

SEE A1/IF111A

M A

T C

H

LI

N E

S E

E A

1/

IF

1D

A5

A5

MEN RESTROOM

F115A

WOMEN RESTROOM

F116A

MEN SHOWERS

F115F

WOMEN SHOWERS

F116F

G6

G7

1. FURNITURE, FIXTURE AND EQUIPMENT PLANS ARE PROVIDED FOR

REFERENCE ONLY.

2. FURNITURE, FIXTURES & EQUIPMENT (FF&E) IS NOT IN BASE CONTRACT AND

SHALL BE PROCURED AS PART OF A SEPARATE CONTRACT LINE ITEM TO

THE BASE BID.

3. REFER TO THE PROJECT'S COMPREHENSIVE INTERIOR DESIGN (CID)

PACKAGE FOR ADDITIONAL FURNITURE DETAILS AND SPECIFICATIONS.

4. POWER AND DATA CONNECTIONS ARE TO BE MADE BY THE CONTRACTOR.

5. FIELD VERIFY ALL MEASUREMENTS AND SITE CONDITIONS PRIOR TO ORDER

ENTRY TO ENSURE PROPER FIT OF ALL FF&E ITEMS. FURNISHINGS SHALL

NOT OVERLAP OR OBSTRUCT DOORWAYS, WALL SWITCHES, THERMOSTATS

OR OTHER WALL MOUNTED ITEMS. MODIFICATIONS TO FURNITURE

LAYOUTS, REQUIRED TO MEET BUILDING CONDITIONS AT THE TIME OF

INSTALLATION, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL

MODIFICATIONS MUST BE APPROVED IN WRITING BY A GOVERNMENT

APPROVED REPRESENTATIVE PRIOR TO FF&E INSTALLATION.

6. REFER TO MEP PLANS TO COORDINATE LIGHT SWITCHES, THERMOSTATS,

DIFFUSERS AND ACCESS PANELS WITH FURNITURE LAYOUTS.

CONTRACTOR SHALL IDENTIFY ANY CONFLICTS WITH FURNITURE LAYOUTS.

AUDIO VISUAL EQUIPMENT AND FURNITURE SHALL BE FUNDED UNDER

SEPARATE CONTRACT. PROVIDE ALL CONDUIT AND POWER FOR THE AV

SYSTEMS.

7. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED FURNITURE,

MARKERBOARDS, TACKBOARDS, AND STORAGE UNITS .

8. GOVERNMENT FURNISHED, GOVERNMENT INSTALLED (GFGI) ITEMS ARE

NOT INCLUDED IN THE FF&E PACKAGE AND WILL BE SHOWN FOR

COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE PRINTERS,

COPIERS, SHREDDERS, REFRIGERATORS, MICROWAVES, FITNESS

EQUIPMENT AND VENDING MACHINES AS INDICATED.

9. A2 WALL CLOCKS TO BE INSTALLED AT 7'-0" A.F.F.

FURNITURE GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

IF111B

F U

R N

IT

U

R E

P L A

N

A R

E A

B K

.B A

R K

E R

L .P

H

IL

L

IP

S

B .F

O R

E T

B .F

O R

E T

SCALE: 1/8" = 1'-0"

A1

FURNITURE PLAN - AREA B

BAY GBAY F

KEY PLAN

B

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

FURNITURE LEGEND

CODE PRODUCT DESCRIPTION QTY.

01 ACCESSORIES

A1 48 X 48 MARKER BOARD 3

A2 WALL CLOCK 14

A3 7 GAL. TRASH CAN 15

A4 RECYCLE STATION 1

A5 BULLETIN BOARD 5

A6 TRASH CAN WITH WHEELS & LID 2

A7 SLIM WASTEBASKET, 23 GAL. 2

02 SEATING

C1 TASK CHAIR 6

C2 GUEST CHAIR 3

C3 BREAK ROOM CHAIR 4

03 DESKS

D1 LAMINATE "L" SHAPE HGT. ADJ. DESK 1

D2 METAL "L" SHAPE W/ HGT. ADJ. DESK 1

04 STORAGE

S1 36"W OPEN SHELVING 9

S2 48"W OPEN SHELVING 46

S3 WARDROBE TOWER, LEFT HINGE 1

S4 STORAGE CREDENZA 2

05 TABLES

T1 BREAK ROOM TABLE, 36W 1

06 WORKSTATIONS

WS-1 4 PACK "L" SHAPE WORKSTATIONS 1

GFGI

G1 MASSAGE CHAIR 4

G2 PRINTER/COPIER 1

G3 REFRIGERATOR 1

G4 MICROWAVE 1

G5 FITNESS EQUIPMENT ITEMS 1

G6 DRYER 1

G7 WASHER 1

M A

R K

D E

S C

R

IP

T I O

N D

A

G1 G1

A3

A2

G1 G1

A3

A2

C1

C2

D2

EXISTING BOILER

ROOM

G113

EXISTING TELECOM

G110

EXISTING MECHANICAL

G108

EXISTING ELECTRICAL

G107

STORAGE

G106

GYMNASIUM

G111

WOMEN

G116

MEN

G118

JAN.

G117

THERAPY AREA

G121

STORAGE

G119

RELAXATION ROOM

G123

PERSONAL TRAINER

G124

RELAXATION ROOM

G122

STORAGE

G120

MECHANICAL

G114

CORRIDOR

G112

VESTIBULE

G115

CORR.

G121A

STORAGE

G109

EXISTING RISER ROOM

G126EXISTING RISER ROOM

G125

MECH

G127

MECH

G128

A6

A6

A2

A2

A2

A3

A2

A3

S4

S4 S2

M A

T C

H

LI

N E

S E

E A

1/

IF

1A

MATCHLINE

SEE A1/IF111D

S2

S2

S2 S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

A1

A5

A5

S2 S2 S2

S2

S2

S2

S2

S2

G5 NOTE: FITNESS AND THERAPY

ITEMS ARE GFGI.

1. FURNITURE, FIXTURE AND EQUIPMENT PLANS ARE PROVIDED FOR

REFERENCE ONLY.

2. FURNITURE, FIXTURES & EQUIPMENT (FF&E) IS NOT IN BASE CONTRACT AND

SHALL BE PROCURED AS PART OF A SEPARATE CONTRACT LINE ITEM TO

THE BASE BID.

3. REFER TO THE PROJECT'S COMPREHENSIVE INTERIOR DESIGN (CID)

PACKAGE FOR ADDITIONAL FURNITURE DETAILS AND SPECIFICATIONS.

4. POWER AND DATA CONNECTIONS ARE TO BE MADE BY THE CONTRACTOR.

5. FIELD VERIFY ALL MEASUREMENTS AND SITE CONDITIONS PRIOR TO ORDER

ENTRY TO ENSURE PROPER FIT OF ALL FF&E ITEMS. FURNISHINGS SHALL

NOT OVERLAP OR OBSTRUCT DOORWAYS, WALL SWITCHES, THERMOSTATS

OR OTHER WALL MOUNTED ITEMS. MODIFICATIONS TO FURNITURE

LAYOUTS, REQUIRED TO MEET BUILDING CONDITIONS AT THE TIME OF

INSTALLATION, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL

MODIFICATIONS MUST BE APPROVED IN WRITING BY A GOVERNMENT

APPROVED REPRESENTATIVE PRIOR TO FF&E INSTALLATION.

6. REFER TO MEP PLANS TO COORDINATE LIGHT SWITCHES, THERMOSTATS,

DIFFUSERS AND ACCESS PANELS WITH FURNITURE LAYOUTS.

CONTRACTOR SHALL IDENTIFY ANY CONFLICTS WITH FURNITURE LAYOUTS.

AUDIO VISUAL EQUIPMENT AND FURNITURE SHALL BE FUNDED UNDER

SEPARATE CONTRACT. PROVIDE ALL CONDUIT AND POWER FOR THE AV

SYSTEMS.

7. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED FURNITURE,

MARKERBOARDS, TACKBOARDS, AND STORAGE UNITS .

8. GOVERNMENT FURNISHED, GOVERNMENT INSTALLED (GFGI) ITEMS ARE

NOT INCLUDED IN THE FF&E PACKAGE AND WILL BE SHOWN FOR

COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE PRINTERS,

COPIERS, SHREDDERS, REFRIGERATORS, MICROWAVES, FITNESS

EQUIPMENT AND VENDING MACHINES AS INDICATED.

9. A2 WALL CLOCKS TO BE INSTALLED AT 7'-0" A.F.F.

FURNITURE GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

IF111C

F U

R N

IT

U

R E

P L A

N

A R

E A

C K

.B A

R K

E R

L .P

H

IL

L

IP

S

B .F

O R

E T

B .F

O R

E T

BAY GBAY F

KEY PLAN

C

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

SCALE: 1/8" = 1'-0"

A1

FURNITURE PLAN - AREA C

FURNITURE LEGEND

CODE PRODUCT DESCRIPTION QTY.

01 ACCESSORIES

A1 48 X 48 MARKER BOARD 3

A2 WALL CLOCK 14

A3 7 GAL. TRASH CAN 15

A4 RECYCLE STATION 1

A5 BULLETIN BOARD 5

A6 TRASH CAN WITH WHEELS & LID 2

A7 SLIM WASTEBASKET, 23 GAL. 2

02 SEATING

C1 TASK CHAIR 6

C2 GUEST CHAIR 3

C3 BREAK ROOM CHAIR 4

03 DESKS

D1 LAMINATE "L" SHAPE HGT. ADJ. DESK 1

D2 METAL "L" SHAPE W/ HGT. ADJ. DESK 1

04 STORAGE

S1 36"W OPEN SHELVING 9

S2 48"W OPEN SHELVING 46

S3 WARDROBE TOWER, LEFT HINGE 1

S4 STORAGE CREDENZA 2

05 TABLES

T1 BREAK ROOM TABLE, 36W 1

06 WORKSTATIONS

WS-1 4 PACK "L" SHAPE WORKSTATIONS 1

GFGI

G1 MASSAGE CHAIR 4

G2 PRINTER/COPIER 1

G3 REFRIGERATOR 1

G4 MICROWAVE 1

G5 FITNESS EQUIPMENT ITEMS 1

G6 DRYER 1

G7 WASHER 1

NOTE:

FITNESS EQUIPMENT ITEMS (G5), QUANTITIES AND EQUIPMENT LAYOUT WILL BE PROVIDED BY

USER.

M A

R K

D E

S C

R

IP

T I O

N D

A

EXISTING TELECOM

F117

AEROBICS

G105

MARTIAL ARTS

G104

SPINNING

G102

STORAGE

G103

JANITOR

F118

LAUNDRY

F119

CORRIDOR

G101

CORRIDOR

F101B

VEST.

G100A

RISER ROOM

G100B

A2

A2

A2

MATCHLINE

SEE A1/IF111C

M A

T C

H

LI

N E

S E

E A

1/

IF

1B

S2

S2S2 S2 S2 S2

S2

S2

S2

S2S2S2S2S2

S2

S2

S2 S2 S2 S2 S2 S2S2

A3

A3A3

G5 NOTE:

ALL FITNESS EQUIPMENT IS GFGI. LAYOUT IS CONCEPTUAL AND

WILL BE PROVIDED BY USER REPRESENTATIVE AT A FUTURE DATE.

G5 NOTE:

ALL FITNESS EQUIPMENT IS GFGI. LAYOUT IS CONCEPTUAL AND

WILL BE PROVIDED BY USER REPRESENTATIVE AT A FUTURE DATE.

G6

G7

1. FURNITURE, FIXTURE AND EQUIPMENT PLANS ARE PROVIDED FOR

REFERENCE ONLY.

2. FURNITURE, FIXTURES & EQUIPMENT (FF&E) IS NOT IN BASE CONTRACT AND

SHALL BE PROCURED AS PART OF A SEPARATE CONTRACT LINE ITEM TO

THE BASE BID.

3. REFER TO THE PROJECT'S COMPREHENSIVE INTERIOR DESIGN (CID)

PACKAGE FOR ADDITIONAL FURNITURE DETAILS AND SPECIFICATIONS.

4. POWER AND DATA CONNECTIONS ARE TO BE MADE BY THE CONTRACTOR.

5. FIELD VERIFY ALL MEASUREMENTS AND SITE CONDITIONS PRIOR TO ORDER

ENTRY TO ENSURE PROPER FIT OF ALL FF&E ITEMS. FURNISHINGS SHALL

NOT OVERLAP OR OBSTRUCT DOORWAYS, WALL SWITCHES, THERMOSTATS

OR OTHER WALL MOUNTED ITEMS. MODIFICATIONS TO FURNITURE

LAYOUTS, REQUIRED TO MEET BUILDING CONDITIONS AT THE TIME OF

INSTALLATION, SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. ALL

MODIFICATIONS MUST BE APPROVED IN WRITING BY A GOVERNMENT

APPROVED REPRESENTATIVE PRIOR TO FF&E INSTALLATION.

6. REFER TO MEP PLANS TO COORDINATE LIGHT SWITCHES, THERMOSTATS,

DIFFUSERS AND ACCESS PANELS WITH FURNITURE LAYOUTS.

CONTRACTOR SHALL IDENTIFY ANY CONFLICTS WITH FURNITURE LAYOUTS.

AUDIO VISUAL EQUIPMENT AND FURNITURE SHALL BE FUNDED UNDER

SEPARATE CONTRACT. PROVIDE ALL CONDUIT AND POWER FOR THE AV

SYSTEMS.

7. PROVIDE BLOCKING AS REQUIRED FOR ALL WALL MOUNTED FURNITURE,

MARKERBOARDS, TACKBOARDS, AND STORAGE UNITS .

8. GOVERNMENT FURNISHED, GOVERNMENT INSTALLED (GFGI) ITEMS ARE

NOT INCLUDED IN THE FF&E PACKAGE AND WILL BE SHOWN FOR

COORDINATION PURPOSES ONLY. GFGI ITEMS MAY INCLUDE PRINTERS,

COPIERS, SHREDDERS, REFRIGERATORS, MICROWAVES, FITNESS

EQUIPMENT AND VENDING MACHINES AS INDICATED.

9. A2 WALL CLOCKS TO BE INSTALLED AT 7'-0" A.F.F.

FURNITURE GENERAL NOTES:

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

IF111D

F U

R N

IT

U

R E

P L A

N

A R

E A

D K

.B A

R K

E R

L .P

H

IL

L

IP

S

B .F

O R

E T

B .F

O R

E T

BAY GBAY F

KEY PLAN

D

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

SCALE: 1/8" = 1'-0"

A1

FURNITURE PLAN - AREA D

FURNITURE LEGEND

CODE PRODUCT DESCRIPTION QTY.

01 ACCESSORIES

A1 48 X 48 MARKER BOARD 3

A2 WALL CLOCK 14

A3 7 GAL. TRASH CAN 15

A4 RECYCLE STATION 1

A5 BULLETIN BOARD 5

A6 TRASH CAN WITH WHEELS & LID 2

A7 SLIM WASTEBASKET, 23 GAL. 2

02 SEATING

C1 TASK CHAIR 6

C2 GUEST CHAIR 3

C3 BREAK ROOM CHAIR 4

03 DESKS

D1 LAMINATE "L" SHAPE HGT. ADJ. DESK 1

D2 METAL "L" SHAPE W/ HGT. ADJ. DESK 1

04 STORAGE

S1 36"W OPEN SHELVING 9

S2 48"W OPEN SHELVING 46

S3 WARDROBE TOWER, LEFT HINGE 1

S4 STORAGE CREDENZA 2

05 TABLES

T1 BREAK ROOM TABLE, 36W 1

06 WORKSTATIONS

WS-1 4 PACK "L" SHAPE WORKSTATIONS 1

GFGI

G1 MASSAGE CHAIR 4

G2 PRINTER/COPIER 1

G3 REFRIGERATOR 1

G4 MICROWAVE 1

G5 FITNESS EQUIPMENT ITEMS 1

G6 DRYER 1

G7 WASHER 1

NOTE:

FITNESS EQUIPMENT ITEMS (G5), QUANTITIES AND EQUIPMENT LAYOUT WILL BE PROVIDED BY

USER.

M A

R K

D E

S C

R

IP

T I O

N D

A

LIGHTING SYSTEM

POWER

OS

LED 2' x 4' LUMINAIRE. (LETTER INDICATES LUMINAIRE TYPE (TYP.), LED SUSPENDED 1' x 4' LUMINAIRE.

RECEPTACLE, DUPLEX, NEMA 5-20R. 18" UNO TO CENTERLINE.

RECEPTACLE, DOUBLE DUPLEX, NEMA 5-20R.

SPECIAL PURPOSE RECEPTACLE. COORDINATE NEMA CONFIGURATION WITH

EQUIPMENT.

JUNCTION BOX, 4" SQUARE MINIMUM, CEILING MOUNTED.

JUNCTION BOX, 4" SQUARE MINIMUM, WALL MOUNTED.

DISCONNECT SWITCH, THREE POLE, NON-FUSED, 30A, NEMA 1 UNO.6'-6" TO TOP

6'-6" TO TOP PANELBOARD, 208Y/120V.

WALL MOUNTED AND CEILING MOUNTED LED EXIT SIGN. SHADED AREA INDICATES

DIRECTION OF FACE. ARROW POINTS IN DIRECTION OF CHEVRON.

1'-6" TO

AF AMP FUSE

AHU AIR HANDLING UNIT

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

JB JUNCTION BOX

MCB MAIN CIRCUIT BREAKER

MLO MAIN LUGS ONLY

PNL PANEL

TTB TELEPHONE TERMINAL BOARD

UNO UNLESS NOTED OTHERWISE

WP WEATHERPROOF

MDF MAIN DISTRIBUTION FRAME

VFD VARIABLE FREQUENCY DRIVE

REF REFRIGERATOR

MNS MASS NOTIFICATION SYSTEM

MNT MOUNTED

LT LIGHT

EWC ELECTRIC WATER COOLER (PROVIDE GFCI RECEPTACLE)

FACP FIRE ALARM CONTROL PANEL

FATC FIRE ALARM TERMINAL CABINET

SWITCH, OCCUPANCY SENSOR, 1000 SQ. FT. AND 180 DEGREE COVERAGE,4'-0" TO

ULTRASONIC AND INFRARED, AUTOMATIC ON/AUTOMATIC OFF.

NIC NOT IN CONTRACT

VACANCY SENSOR, CEILING MOUNTED, ULTRASONIC AND INFRARED, 2000 SF

COVERAGE, QUICK TO INSTALL CONNECTOR

OS

UTP UNSHIELDED TWISTED PAIR

OS OCCUPANCY SENSOR

BCW BARE COPPER WIRE

SWITCH, DIMMER.4'-0" TO

RECEPT RECEPTACLE

FRAP FIRE ALARM REMOTE ANNUNCIATOR PANEL

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

SEGB SERVICE ENTRANCE GROUND BAR

ELECTRICAL CONNECTION, D INDICATES DROPCORD

PROVIDE LOCAL DISCONNECTING MEANS RATED FOR

EQUIPMENT PROVIDED.

CH COUNTER HEIGHT

GROUND BAR

MOTOR STARTER, COMBINATION DISCONNECT. PROVIDE MOTOR OVERLOADS4'-0" TO

SIZED AS REQUIRED FOR THE MOTOR BEING SERVED.

SWITCH, TWO POLE. 20 AMP 120 VOLT.4'-0" TO

MOTOR RATED SWITCH. (MANUAL MOTOR STARTER).4'-0" TO

COORDINATE POLE AND AMPACITY OF MOTOR BEING CONTROLLED.

LED WALL MOUNTED 1' x 4' LUMINAIRE.

LED 6" DOWNLIGHT FOR WET LOCATIONS.

INT INTERCOM

PANEL DESIGNATION AND NUMBER INDICATES CIRCUIT ID (TYP.),

NL INDICATES NIGHT LIGHT TO BE WIRED AHEAD OF SWITCHED LEG.

A2

CP COPIER

F/P FAX/PRINTER

PA PUBLIC ADDRESS

OVAL INDICATES CEILING MOUNTING, RECTANGLE INDICATES FLOOR MOUNTING.

LED 2' x 2' LUMINAIRE. SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

LED SURFACE MOUNTED 1' x 4' LUMINAIRE.

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

RECEPTACLE, SIMPLEX, NEMA 5-20R. 8'-0" TO CENTERLINE, UNO.

KEYED SWITCH4'-0" TO

E

S

S

D S

M S

K S

J

J

LC

LC

LC

LC

LC

LC

LC

DDC/BAS DIRECT DIGITAL CONTROL PANEL (HVAC)

D

UDS UTILITY DISTRIBUTION SYSTEM

LED PENDANT HUNG LUMINAIRE. SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

RECESSED DOWN LIGHT, SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

1HC1-1

SHADING INDICATES EMERGENCY LUMINAIRE.

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

LED SURFACE RESISTANT 2' x 4' LUMINAIRE.

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

SWITCH, THREE POLE. 20 AMP 120 VOLT.4'-0" TOS LC

SWITCH, FOUR POLE. 20 AMP 120 VOLT.4'-0" TOS LC

X

X

D

B2

A AMP

KVA KILOVOLT AMPERE

V VOLT

LINETYPES

INDICATES TO BE DEMOLISHED

INDICATES EXISTING TO REMAIN

INDICATES NEW

OH OVERHEAD

ABBREVIATIONS:

A

C

N

J

L

S

M

AFF ABOVE FINISHED FLOOR

4'-0" TO LC VARIABLE FREQUENCY DRIVEVFD

VS

SWITCH, VACANCY SENSOR, 1000 SQ. FT. AND 180 DEGREE COVERAGE,4'-0" TO

ULTRASONIC AND INFRARED, MANUAL ON/AUTOMATIC OFF.

S LC

GENERAL NOTES:

1. INSTALL ELECTRICAL WORK COVERED BY THE BOUND SPECIFICATIONS AND APPROVED DRAWINGS.

PROVIDE MATERIAL, LABOR, TRANSPORTATION, TOOLS, AND SUPERVISION NECESSARY TO COMPLETE THE TOTAL ELECTRICAL JOB. ITEMS NOT SPECIFICALLY MENTIONED HEREIN WHICH ARE OBVIOUSLY

NECESSARY TO MAKE A COMPLETE WORKING INSTALLATION SHALL BE PROVIDED.

2. WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE ENFORCED EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA 70, NATIONAL ELECTRICAL SAFETY CODE, ANSI, UFC 3-520-01, AND LOCAL AND STATE CODES AND REGULATIONS. OBTAIN AND PAY FOR PERMITS AND INSPECTIONS

REQUIRED BY THE BUILDING AND SAFETY CODES AND ORDINANCES, AND THE RULES AND

REGULATIONS OF ANY LEGAL BODY HAVING JURISDICTION.

3. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF ELECTRICAL EQUIPMENT. COORDINACE DEVICE LOCATIONS WITH DOOR SWINGS, CABINETS, AND COUNTERS AS

INDICATED ON THE ARCHITECTURAL DRAWINGS. DO NOT SCALE ELECTRICAL PLANS. OBTAIN

DIMENSIONS FOR LAYOUT OF EQUIPMENT FROM ARCHITECTURAL PLANS UNLESS INDICATED ON

ELECTRICAL PLANS.

4. WHEN MOTORS AND EQUIPMENT FURNISHED ARE LARGER OR DIFFER IN SIZES INDICATED, INCLUDE THE COST OF ADDITIONAL ELECTRICAL SERVICE AND RELATED WORK UNDER THE SECTION THAT SPECIFIED THE MOTOR OR EQUIPMENT. WHERE FUSE PROTECTION IS SPECIFICALLY INDICATED OR REQUIRED BY THE EQUIPMENT MANUFACTURER, PROVIDE FUSED SWITCHES IN LIEU OF NON-FUSED

SWITCHES INDICATED.

5. LOWER CASE LETTERS BESIDE TOGGLE SWITCHES, CONTACTORS, CONTROL STATIONS, JUNCTION BOXES AND LIGHTING FIXTURES INDICATE SWITCH AND FIXTURE RELATIONSHIP. FIXTURES WITH MORE THAN ONE LETTER SHALL BE WIRED FOR MULTI-LEVEL OPERATION WITH OUTBOARD AND INBOARD

LAMPS CONTROLLED SEPARATELY.

6. WIRE AND CONDUIT FOR MOTOR AND EQUIPMENT LOADS SHALL BE CONTINUOUS IN SIZE FROM

SOURCE TO FINAL CONNECTION.

7. WHERE BRANCH CIRCUIT HOMERUNS ARE LABELED "SPLIT CIRCUIT" (SC), THE BRANCH CIRCUIT NUMBER INDICATED HAS BEEN USED ON MORE THAN ONE HOMERUN INDICATOR. INSTALL ONLY ONE CONDUCTOR PER CIRCUIT BREAKER POLE WITHIN PANELBOARD ENCLOSURE. SPLICES NECESSARY TO SPLIT THE CIRCUIT SHALL BE MADE IN A SEPARATE SPLICE BOX OUTSIDE OF THE PANEL ENCLOSURE.

8. LOW ENERGY CONTROL WIRING BETWEEN OCCUPANCY SENSORS AND POWER PACKS HAVE NOT BEEN SHOWN, BUT SHALL BE PROVIDED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.

9. MOUNTING HEIGHTS INDICATED ARE THE CENTERLINE OF THE DEVICE UNLESS NOTED OTHERWISE.

10. COORDINATE INSTALLATION OF ANY DEVICE LOCATED IN MILLWORK WITH ARCHITECTURAL DRAWINGS

AND DETAILS PRIOR TO ROUGHING IN BOXES AND ROUTING CONDUIT. COORDINACE WITH

ARCHITECTURAL REFLECTED CEILING PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF LIGHT

FIXTURES IN LAY-IN DRYWALL CEILINGS, AND ON INTERIOR AND EXTERIOR WALLS.

11. ELECTRICAL COMPONENTS INCLUDING BUT NOT LIMITED TO CONDUCTOR SIZE, OVERCURRENT PROTECTIVE DEVICES AND DISCONNECT SWITCHES ARE BASED ON POWER REQUIREMENTS AS SHOWN

ON THE CONTRACT DOCUMENTS.

12. COORDINATE THE NEED FOR POWER FOR ALL MECHANICAL AND PLUMBING. THIS POWER MAY ONLY BE FOR CONTROLS OR IT MAY BE POWER FOR FANS, COMPRESSORS, HEATER COILS OR HEAT TRACE.

REVIEW THE MECHANICAL AND PLUMBING AND PROVIDE POWER FOR EACH PIECE OF EQUIPMENT

WHERE POWER IS REQUIRED. DISCONNECTS SHALL BE PROVIDED IN ACCORDANCE WITH CODE

REQUIREMENTS WHETHER OR NOT SPECIFICALLY INDICATED ON THE DRAWINGS.

13. FIRE RATED WALLS AND FLOORS WHICH HAVE A CONDUIT OR OTHER ELECTRICAL PENETRATIONS SHALL BE SEALED EQUAL TO THE RATING OF THE WALL OR FLOOR BEFORE THE PENETRATION IS MADE.

SEALING SHALL BE OF A UL RATED AND LISTED ASSEMBLY FOR THE SEALING MATERIAL AND METHOD.

DEVICE OUTLETS SHOWN BACK-TO-BACK IN WALLS SHALL BE INSTALLED WITH A MINIMUM OF 24" BETWEEN DEVICES MEASURED FROM INSIDE EDGES OF BOXES, EXCEPTION WHERE PUTTY PADS OR OTHER IBC APPROVED METHOD IS USED TO MAINTAIN FIRE RATING OF WALL. BOX OPENING SHALL

OCCUR ONLY ON SIDE OF THE FRAMING SPACE AND SHALL NOT EXCEED 16 SQUARE INCHES.

14. LIGHT SWITCHES SHALL BE MOUNTED NO MORE THAN 6" FROM EDGE OF DOOR FRAME. LIGHT SWITCHES AND RECEPTACLES SHALL BE BY THE SAME MANUFACTURER. COVERPLATES SHALL BE AS PER THE SPECIFICATIONS AND SHALL MATCH THE COLOR OF THE DEVICE. DEVICE COLOR TO BE

SELECTED BY THE ARCHITECT UNLESS OTHERWISE NOTED.

15. TWO OR MORE ADJACENT POWER OR COMMUNICATION DEVICES SHALL BE GANGED WITH A COMMON FACEPLATE. IF THEY CAN NOT BE GANGED THEY SHALL BE INSTALLED WITH A MINIMUM DISTANCE

BETWEEN DEVICES.

16. COMBINED CIRCUITS ARE ALLOWED IN A SINGLE CONDUIT PER THE FOLLOWING CONDITIONS:

17. EMERGENCY LIGHTING SYSTEM SHALL BE TESTED FOR CODE COMPLIANCE PRIOR TO INSPECTION.

COORDINATE FIELD TESTING WITH AUTHORITY HAVING JURISDICTION.

18. EQUIPMENT SHALL BE CONSTRUCTED OF MATERIAL SUITABLE FOR THE ENVIRONMENT IN WHICH IT IS

INSTALLED WITH THE APPROPRIATE NEMA ENCLOSURE RATING.

19. MAINTAIN RECOMMENDED SEPARATION BETWEEN WIRING OF DIFFERENT SYSTEMS AND FROM

INTERFERENCE PRODUCING ELECTRICAL DEVICES SUCH AS FLUORESCENT LIGHTS, BALLASTS,

TRANSFORMERS, RELAYS, AND MOTOR CONTROLS.

20. EQUIPMENT GROUNDING CONDUCTORS SHALL BE INSTALLED IN ALL RACEWAYS.

21. PERFORM NECESSARY TESTS TO ENSURE THE INSTALLATION IS FREE FROM IMPROPER GROUNDS AND

FROM SHORTED AND/OR OPEN CIRCUITS BEFORE CIRCUITS ARE PLACED IN OPERATION.

22. PROVIDE WARNING SIGNS FOR ARC FLASH PROTECTION FOR SWITCHBOARDS AND PANELBOARDS IN ACCORDANCE WITH SPECIFICATION SECTION 26 20 00, PARAGRAPH ENTITLED "WARNING SIGNS".

23. SERVICE EQUIPMENT FAULT AVAILABLE MARKED PER NEC 110.24 (A).

24. ELECTRICAL CONDUIT AND WIRING SIZES FOR CIRCUITING ARE NOT SHOWN ON THE DRAWINGS.

CONDUIT AND WIRE SIZES ARE SHOWN ON THE PANELBOARD SCHEDULES.

• THE REQUIRED 40% MAXIMUM FILL RATE IS TO BE PROVIDED IN ALL CONDUITS PER NFPA 70.

• SINGLE PHASE CIRCUITS SHALL HAVE A DEDICATED NEUTRAL.

• A MAXIMUM OF THREE 20 AMP, SINGLE POLE CIRCUITS MAY BE COMBINED WITH A COMMON

HOMERUN.

• CONTRACTOR SHALL DERATE CONDUCTOR CAPACITY ACCORDING TO THE NUMBER OF

CURRENT CARRYING CONDUCTORS IN COMPLIANCE WITH THE NFPA 70.

• BRANCH CIRCUITS LARGER THAN 20 AMPS SHALL BE SEPARATELY HOMERUN TO THE PANEL.

A2

1HC1-1

D

B2

A

C

N

J

L

S

M

SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

SHADING INDICATES EMERGENCY LUMINAIRE.

RECEPTACLE, DUPLEX, NEMA 5-20R. 18" UNO TO CENTERLINE.

GFCI (GROUND FAULT CURRENT INTERRUPTOR) WHERE INDICATED.

GFCI

LED HIGH BAY PENDANT

SS SEE LUMINAIRE SCHEDULE FOR ADDITIONAL INFORMATION.

SHADING INDICATES EMERGENCY LUMINAIRE.

RECEPTACLE, DUPLEX, NEMA 5-20R. 18" UNO TO CENTERLINE.

WEATHERPROOF GFCI (GROUND FAULT CURRENT INTERRUPTOR) WHERE INDICATED.

GFCI/WP

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

E-001

E L E

C T

R

IC

A L G

E N

E R

A L N

O T

E S

S

Y M

B O

L S

A N

D A

B B

R E

V

IA

T

IO

N S

S D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

M A

R K

D E

S C

R

IP

T

IO

N D

A

EE

E

E

EE

E

E

E

E

E

E

E

E

E

E E

GEN E

EE

E

E

E

E

E E

E E

E

E

E

E

E

E

E

E

E E

E

EE

E

E E E E

E

E

EE

E

E

E

E

E

E

E

K

E

E

E

E

EE

E

E

E

M M

E

E

E

E

E

E

E

E

E E

A C

P

M

MM

J

E

E

J J

J

J J

J

E

E

E

E

E E E E E

E

J

KK

1 2 3 4 5 6 7

A

B

C

D

E

F

G

H

I

J

8 9 10 11 12 13

GFCI

48" AFF

GFCI

48" AFF

GFCI

GFCI

48" AFF

GFCI

48" AFF

GFCI

48" AFF

GFCI/WP GFCI

48" AFF

GFCI

48" AFF

GFCI

48" AFF

GFCI

48" AFF

GFCI/WPGFCI/WP

GFCI/WP

9' AFF

M437

BOILER

32FDP 32FM1

32FM2

32FRE

32FRB

32FRA

32FL1

32FRC32FRD

32GM2

32GCC

32GC

32GE

32GF

32GRD

32GM1

32GE JR

GFCIGFCI

GFCI

GFCI

GFCI

GFCI

GFCI

48" AFF

GFCI

GENERATOR QUICK-

CONNECT DOUBLE

THROW SAFETY SWITCH

/A1 EP111B /A1 EP111B

/A1 EP111A/A1 EP111A

/A1 EP111C /A1 EP111C

/A1 EP111D

A

E

P C

A

E

P A

A

E

P C

A

E

P A

A

E

P D

A

E

P B

GFCI/WPGFCI/WP

GFCI/WP

GFCI/WP

32GC-6

32GC-8

32GC-9

32GC-14

32GC-15

32GC-20

32GC-20

TYP.

VFD

VFD

VFD

VFD

EP401

C1

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

EP111

O V

E R

A L L E

L E

C T

R

IC

A L P

O W

E R

P L A

N S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

SCALE: 1/16" = 1'-0"

A1

OVERALL ELECTRICAL POWER PLAN

0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A

GEN

E

EE

E

E E E

E

E

E

E E

E

E

E

M

M

J

E

J JJ J

E

E

E

E

J

1 2 3 4 5 6 7

A

B

C

D

E

F

G

H

EXISTING RISER

ROOM

F103A

EXISTING RISER

ROOM

F103

PROGRAM DIR.

F104

CONTROL DESK/

SUPPORT STAFF

F102

EXISTING

ELECTRICAL

F107

BREAK

F106

EXISTING

MECHANICAL

F108

STORAGE

F109

CORRIDOR

F109A

CORRIDOR

F101A

BREEZEWAY

F100

ENTRY/ LOBBY

F101

WEIGHT

F110

RACQUETBALL

COURT

F114

FUNCTIONAL

FITNESS

F113

CIRCUIT

F112

CARDIO

F111

CORRIDOR

F101A

GFCI

48" AFF GFCI

48" AFF

GFCI

GFCI/WP

32FDP 32FM1

32FM2

32FRE

32FRB

32FRA

32FL1

32FRC

32FRD

EP401

A1

GENERATOR QUICK-

CONNECT DOUBLE

THROW SAFETY SWITCH

/A1 EP111B /A1 EP111B

/A1 EP111C

A

E P

C

A

E

P C

A

E

P D

GFCI/WP

32FRA-2

32FRA-2

32FRA-2

32FRA-2

32FRA-4

32FRA-4

32FRA-7

32FRA-6

32FRA-6

32FRA-6

32FRA-9

32FRA-9

32FRA-31

32FRA-1232FRA-1232FRA-12

32FRA-16

32FRA-16

32FRA-16

32FRA-16

32FRA-17

32FRA-18

32FRA-19

32FRA-20

32FRA-21

32FRA-22

32FRA-23

32FRA-14

32FRA-14

32FRA-14

32FRA-14

32FRA-15

32FRA-1532FRA-15 32FRA-15 32FRA-15

32FRA-12

32FRA-14

32FRA-14

32FRA-15

32FRA-15

32FRA-12

32FRA-12

32FRA-14

32FRA-6

32FRA-24

32FRA-25

32FRA-26

32FRA-27

32FRA-28

32FRA-29

32FRA-30

32FRA-10 32FRA-10 32FRA-11

32FRA-13 32FRA-13

AHU-1

DOA-1

CH-1 (EX)

OAH-1

UH-3

VAV-F112

VAV-F100

VAV-F102

VAV-F109

VAV-F106

VAV-F104

VAV-F114

VAV-F110

UH-4

UH-2

32FRB-1

32FRB-1

32FRB-1

32FRB-1

32FRB-2

32FRB-2

32FRB-2

32FRB-2

32FRA-36

32FRA-36

32FRA-36

32FRA-36

32FRA-37

32FRA-37

32FRA-37

32FRA-37

1 TYP.

32GE-31,33,35

32FRB-23

32FRB-23

UH-1

32FRB-23

EH-1

32FM1-34,36,38

FCU-1

CUH-2

32FRB-22

32FRB-25

HVLS-1

32FRA-40

32GC-41

32FM2-9,11

F

M -1

F

M -1

F

M -1

32FM2-16 32FM2-1632FM2-16 32FM2-16

32FM2-17

32FM2-17

32FM2-17

32FM2-17

F

R A

-8

GENERAL NOTE:

COORDINATE EXACT LOCATION OF POWER OUTLETS AND ELECTRICAL

CONNECTIONS WITH FINAL LOCATIONS OF MECHANICAL UNITS AND

FITNESS CENTER EQUIPMENT.

KEYED NOTES:

1. POWER FOR PENDANT MOUNTED TELEVISION MONITORS.

TELEVISION MONITORS NIC.

2. POWER FOR ACCESS CONTROL SYSTEM.

3. JUNCTION BOX FOR ELECTRICAL WIRING TO WORKSTATIONS.

PROVIDE FLEXIBLE METALLIC CONDUIT WHIP AND ELECTRICAL

WIRING FROM THE JUNCTION BOX TO THE WORKSTATIONS FOR

CONNECTION TO THE ELECTRICAL RECEPTACLES. ELECTRICAL

RECEPTACLES ARE PROVIDED BY THE FURNITURE VENDOR.

4. HVLS-1 FAN CONTROLLER.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

EP111A

E L E

C T

R

IC

A L P

O W

E R

P L A

N

A R

E A

A S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL POWER PLAN - AREA A

BAY GBAY F

KEY PLAN

A

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A

E E

E

E

E E

EE

E

E

E

E

M M

E

E

E

E

J

JE E

1 2 3 4 5 6 7

H

I

J

MEN LOCKER

F115C

WOMEN LOCKER

F116C

CORRIDOR

F101B

LAUNDRY

F119

JANITOR

F118

EXISTING TELECOM

F117

MECH.

F116E

STEAM

F116D

STEAM

F115D

MECH.

F115E

SAUNA

F115B

SAUNA

F116B

GFCI

48" AFF GFCI

48" AFF

GFCI

48" AFF

GFCI

GFCI

GFCI

48" AFF

GFCI

/A1 EP111A

/A1 EP111A

A

E

P D

32FRA-35

32FRA-32

32FRA-32

32FRA-32

32FRA-32

32FRA-16

32FRA-34

32GF-1,3,5

32FRA-34

32FRA-32

32FRA-32

32FRA-34

32FRA-34

32GF-2,4,6

32FRA-35

32FRA-35

32FRA-35

F

M -4

F

M -6

VAV-F116

VAV-F115

VAV-F119

IHP-1

WS

32FRB-3

32FRB-3

32FRB-3

32GC-28,30,32 32GC-29,31,33

32FRA-39,41

32FRA-38

32FRB-21

32FRB-21

32FRB-21

32FRB-21

32FM2-5,7

CUH-1

CF-1

CF-2

CF-3

CF-4

32FRB-20

CUH-4

32FRB-24

EP401

C3

GFCI

32FM1-2

32FM2-1,3

32FM2-2,4

GFCI/WP GFCI/WP

32FRA-42 32FRA-42

32FT

32FM2-16

32FM2-1632FM2-17

32FM2-17

GFCI GFCI

32GC-42 32GC-42

GENERAL NOTE:

COORDINATE EXACT LOCATION OF POWER OUTLETS AND ELECTRICAL

CONNECTIONS WITH FINAL LOCATIONS OF MECHANICAL UNITS AND

FITNESS CENTER EQUIPMENT.

KEYED NOTES:

1. 3-SPEED FAN CONTROLLER TO BE PROVIDED BY MECHANICAL,

INSTALLED BY ELECTRICAL.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

EP111B

E L E

C T

R

IC

A L P

O W

E R

P L A

N

A R

E A

B S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

BAY GBAY F

KEY PLAN

B

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL POWER PLAN - AREA B

M A

R K

D E

S C

R

IP

T

IO

N D

A

E

E

E

E

E

E

E

E

E

E

E

E

K

E

E

E

E

E

KK

A

B

C

D

E

F

G

8 9 10 11 12 13

MECH

G128

MECH

G127

PERSONAL TRAINER

G124

THERAPY AREA

G121

VESTIBULE

G115

MECHANICAL

G114

EXISTING BOILER

ROOM

G113

WOMEN

G116

MEN

G118

STORAGE

G119

STORAGE

G120

CORR.

G121A

CORRIDOR

G112

GYMNASIUM

G111

EXISTING TELECOM

G110

STORAGE

G109

EXISTING

MECHANICAL

G108

EXISTING

ELECTRICAL

G107

GFCI

48" AFF

GFCI

48" AFF

GFCI

48" AFF

GFCI

48" AFF

GFCI/WP GFCI/WP

GFCI/WP

9' AFF

BOILER

32GM2

32GCC

32GC

32GE

32GF

32GRD

32GM1

32GE JR

GFCI

GFCI

GFCI

GFCI

EP402

A2

EP401

A3

2 2

RELAXATION ROOM

G123

RELAXATION ROOM

G122

/A1 EP111D

A

E

P A

A

E

P A

A

E

P D

GFCI/WP

32FDP-14,16,18

32GC-1

32GC-1

32GC-1

32GC-1

32GC-2 32GC-2

32GC-2 32GC-2

32GC-2

32GC-2

32GC-2

32GC-2

32GC-3 32GC-3

32GC-4

32GC-4

32GC-4 32GC-4

32GC-4

32GC-4

32GC-5

32GC-5

32GC-5

32GC-5

32GC-5

32GC-6

32GC-6

32GC-6

32GC-6

32GC-8

32GC-8

32GC-8

32GC-8

32GC-9 32GC-9

32GC-9

32GC-10

32GC-10 32GC-10 32GC-10

32GC-10

32GC-11 32GC-12

32GC-13 32GC-13

32FM1-21

32FM1-20 32FM1-20

32FM1-20

32FM1-20

32FM1-2032FM1-20

32FM1-22 32FM1-22

32FM1-23 32FM1-23

32FM1-23

32GC-14

32GC-14

32GC-14

32GC-15 32GC-15

CH-1 (EX)

CH-2

HWP-1B

HWP-1A

HX-1

VAV-G121

VAV-G124

VAV-G122

HX-2

IHP-2

HWP-2B

HWP-2A VAV-G118

VAV-G123

BAS-1

32GE-15

32GE-15

32GE-15

32GE-15

32GE-17,19,21 32GE-20,22,24

32GE-26,28,3032GE-23,25,27

32FM2-6,8

32GC-22

32FM1-31 32FM1-32

32GC-27

32FM1-33

VFD HWP-1A

VFD HWP-1B

VFD HWP-2A

VFD HWP-2B

4 4

32GC-37

32GC-37

32GC-38 32GC-38

32GE-15

CUH-3

32GC-39

EP401

A4

32GT

32GC-41

32GC-41

10' AFF

32FM2-17

KEYED NOTES:

1. PROVIDE RECEPTACLE AT 15' AFF.

2. COORDINATE CEILING MOUNTED RECEPTACLES WITH LOCATION OF BASKETBALL GOAL/SHOT CLOCK.

3. KEYED SWITCH TO BE PROVIDED BY ROLLUP DIVIDER MANUFACTURER.

4. PROVIDE NEMA L14-20R RECEPTACLE FOR ELECTRIC WINCH CONNECTION. PROVIDE RECEPTACLE

WITHIN 6'-0" OF ELECTRIC WINCH.

5. PROVIDE (2) KEYED SWITCHES: (1) FOR RAISING/LOWERING EACH BASKETBALL GOAL. SEE KEYED

NOTE #4.

GENERAL NOTE:

COORDINATE EXACT LOCATION OF POWER OUTLETS AND ELECTRICAL

CONNECTIONS WITH FINAL LOCATIONS OF MECHANICAL UNITS AND

FITNESS CENTER EQUIPMENT.

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

EP111C

E L E

C T

R

IC

A L P

O W

E R

P L A

N

A R

E A

C S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL POWER PLAN - AREA C

BAY GBAY F

KEY PLAN

C

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A

E

E

MM

E

E E E

H

I

J

8 9 10 11 12 13

STORAGE

G106

AEROBICS

G105

MARTIAL ARTS

G104

SPINNING

G102

CORRIDOR

G101

STORAGE

G103

RISER ROOM

G100B

VEST.

G100A

M437

/A1 EP111C /A1 EP111C

A

E

P B

GFCI/WPGFCI/WP

32GC-15

32GC-15

32GC-16 32GC-16

32GC-16

32GC-16

32GC-17 32GC-17

32GC-18

32GC-18

32GC-18 32GC-18

32GC-18

32GC-18

32GC-19

32GC-19

32GC-19

32GC-19

32GC-20 32GC-20 32GC-20 32GC-20

32GC-20

32GC-2032GC-20

32GC-21

32GC-21 32GC-21

VAV-G105

VAV-G102

VAV-G104

32GE-32

32GE-32

32GE-32

32GE-37,39,41

32GE-34,36,38

HVLS-3

HVLS-2

32FT

32GC-41

32FM2-10,12

32FM2-17 32FM2-17

32FM2-17

32GC-18

GENERAL NOTE:

COORDINATE EXACT LOCATION OF POWER OUTLETS AND ELECTRICAL

CONNECTIONS WITH FINAL LOCATIONS OF MECHANICAL UNITS AND

FITNESS CENTER EQUIPMENT.

KEYED NOTES:

1. FAN CONTROLLER (HLVS-2 & HVLS-3).

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

EP111D

E L E

C T

R

IC

A L P

O W

E R

P L A

N

A R

E A

D S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

SCALE: 1/8" = 1'-0"

A1

ELECTRICAL POWER PLAN - AREA D

BAY GBAY F

KEY PLAN

D

4'0 8' 16'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A

GENERAL NOTES: COMMUNICATIONS LEGEND: ABBREVIATIONS:

VOICE OUTLET. 48" UNO TO CENTERLINE.

DATA OUTLET WITH (2) DATA JACKS. 18" UNO TO CENTERLINE.

COMBINATION TELEPHONE / DATA OUTLET. 1 VOICE AND 1 DATA JACK

AFF ABOVE FINISHED FLOOR

AHU AIR HANDLING UNIT

C CONDUIT

CB CIRCUIT BREAKER

CKT CIRCUIT

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GND GROUND

MB MAIN BREAKER

MLO MAIN LUGS ONLY

PNL PANEL

TTB TELEPHONE TERMINAL BOARD

UNO UNLESS NOTED OTHERWISE

WP WEATHERPROOF

NL NIGHT LIGHT

MDF MAIN DISTRIBUTION FRAME

VFD VARIABLE FREQUENCY DRIVE

MNS MASS NOTIFICATION SYSTEM

MOUNTED MOUNTED

RCPT RECEPTACLE

LT LIGHT

CFL COMPACT FLUORESCENT

NIC NOT IN CONTRACT

TELEPHONE TERMINAL BOARD WITH DOUBLE DUPLEX OUTLET

IN A COMMON FACEPLATE ON AN OUTLET BOX AND SPACE FOR TWO MORE JACKS. 18" UNO TO CENTERLINE.

UTP UNSHIELDED TWISTED PAIR

SWBD SWITCHBOARD

OS OCCUPANCY SENSOR

BCW BARE COPPER WIRE

PROJ SCRN PROJECTION SCREEN

RECEPT RECEPTACLE

GFGI GOVERNMENT FURNISHED GOVERNMENT INSTALLED

SEGB SERVICE ENTRANCE GROUND BAR

CH COUNTER HEIGHT

ATS AUTOMATIC TRANSFER SWITCH

DATA OUTLET WITH (1) DATA JACK. 18" UNO TO CENTERLINE.

JB JUNCTION BOX

AC ABOVE COUNTER

DDC/BAS DIRECT DIGITAL CONTROL/BUILDING AUTOMATION SYSTEM

IWB INTERACTIVE WHITEBOARD

NEC NETWORK ENTERPRISE CENTER

1. ALL TELECOMMUNICATIONS EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE

WITH NFPA 70, DDESS SPECIAL SYSTEMS DESIGN GUIDE, AND EIA/TIA CRITERIA.

2. ALL OPEN CABLES IN PLENUM RETURN AIR SPACE SHALL BE PLENUM RATED.

3. CAT6 DATA AND VOICE CABLING FROM THE COMM. ROOM TO THE USER OUTLETS SHALL BE

JACKETED AND TERMINATED T568B.

4. FOR GROUNDING OF TELECOMMUNICATION EQUIPMENT ALL GROUND WIRE LUGS SHALL BE

2-HOLE IRREVERSIBLE CRIMP-TYPE LUGS.

5. ALL COMMUNICATION CABLES SHALL BE TESTED, BOTH COPPER AND FIBER, AS

SPECIFIED IN SECTION 27 10 00.

DATA OUTLET WITH (1) DATA JACK, INTENDED FOR CONNECTION TO TELEVISION

DATA OUTLET, QUAD WITH 4 DATA JACKS. 18" UNO TO CENTERLINE.

SECURITY LEGEND:

TGB TELECOMMUNICATIONS GROUNDING BUSBAR

TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR

JUNCTION BOX 18"AFF WITHIN WALL WITH 1-1/2" CONDUIT RACEWAY TO

COMMUNICATIONS CABLE TRAY. FOR INTERFACE OF CAT 6 CABLING CONNECTION

TO SYSTEMS FURNITURE.

J

6. FOR ACCESS CONTROL SYSTEM, THE CONTRACTOR SHALL PROVIDE CONDUIT

AND JUNCTION BOX INFRASTRUCTURE ONLY. ACCESS CONTROL SYSTEM

CONTROL PANEL, KEYPADS/CARD READERS, REX DEVICES, AND ASSOCIATED

WIRING SHALL BE PROVIDED BY OTHERS UNDER A SEPERATE CONTRACT.

SINGLE DATA OUTLET, CEILING MOUNTED FOR PROJECTOR.

C

ELECTROMAGNETIC DOOR LOCKML

ACCESS CONTROL SYSTEM CONTROL PANEL LOCATIONACP

REX REQUEST TO EXIT

TV

CLOSED CIRCUIT TELEVISION (CCTV)

CEILING MOUNTED DATA OUTLET, QUAD WITH 4 DATA JACKS.

CEILING MOUNTED TELEPHONE OUTLET.

FLOOR MOUNTED DATA OUTLET, QUAD WITH 4 DATA JACKS.

FLOOR MOUNTED TELEPHONE OUTLET.

FLOOR MOUNTED TELEPHONE / DATA OUTLET. 1 VOICE AND 1 DATA JACK.

INTERCOM SYSTEMI

SOUND ENHANCEMENT SPEAKER SYSTEM, CEILING MOUNTEDS

SOUND ENHANCEMENT SPEAKER SYSTEM, WALL MOUNTEDS

CARD READERCR

BALANCE MAGNETIC SWITCHBMS

WIRELESS ACCESS POINTWAP

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

T-001

T E

L E

C O

M M

U N

IC

A

T

IO

N S

G E

N E

R A

L N

O T

E S

S

Y M

B O

L S

A N

D A

B B

R E

V

IA

T

IO

N S

S D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

M A

R K

D E

S C

R

IP

T

IO

N D

A

S

I s

S

S

S S

S

S s s s s s s s s s s s s s s s s s

SS

SS

s s s s s s

S

S

S

S

WAP

WAP

WAP

WAP

CR

S

S

S

S s s

J

J

1 2 3 4 5 6 7

A

B

C

D

E

F

G

H

I

J

8 9 10 11 12 13

/A1 T111A

/A1 T111B

/A1 T111A

/A1 T111B

/A1 T111C

/A1 T111D

/A1 T111C

/A1 T111D

A

T

C

A

T

A

A

T

C

A

T

A

A

T

D

A

T

B

TYP.

TV

TV

TV

TV

TV

TV

TV

TV

ML

ML

BMS

BMS

BMSBMS

BMSBMS

BMS

BMSBMS

BMS BMSBMS

US Army Corps of Engineers ®

SHEET

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

N O

R F

O

T

R

IC

T N

O R

F O

L K

V

IR

G

IN

IA

READY TO ADVERTISE

D E

F E

N S

E S

U P

P L Y

C E

N T

E R

R

IC

H M

O N

D

D S

C R

V

IR

G

IN

IA

C O

N V

E R

T B

B

A Y

S F

G

F

IT

N

E S

S C

E N

T E

R P

R O

J E

C T

E

C E

N O

V E

M B

W -1

-R

-0

W -1

-R

-0

T-111

O V

E R

A L L T

E L E

C O

M M

U N

IC

A

T

IO

N S

P L A

N S

D

A V

ID

S

O N

R R

U S

S E

L L

W W

E B

B

W W

E B

B

SCALE: 1/16" = 1'-0"

A1

OVERALL TELECOMMUNICATIONS PLAN

0 8' 16' 32'

GRAPHIC SCALE

PLAN NORTH

M A

R K

D E

S C

R

IP

T

IO

N D

A

I s s s

SS

SS

s s s s s

WAP

CR

J

1 2 3 4 5 6 7

A

B

C

D

E

F

G

H

EXISTING RISER

ROOM

F103A

EXISTING RISER

ROOM

F103

PROGRAM DIR.

F104

STORAGE/ EQUIP.

F105 CONTROL DESK/

SUPPORT STAFF

F102

EXISTING

ELECTRICAL

F107

BREAK

F106

CORRIDOR

F107A

EXISTING

MECHANICAL

F108

BREEZEWAY

F100

ENTRY/ LOBBY

F101

CIRCUIT

F112

WEIGHT

F110

CORRIDOR

F101A

FUNC…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .