Section_J _Attachment_9 _Contract_Drawing_List _RFP_A00008.pdf

PDF 105 KB Posted

Attached to
United States Coast Guard Phase II Fast Response Cutter (FRC) Request for Proposals (RFP)
Solicitation number
HSCG23-15-R-FRCPII
Issued by

About this file

Section J Attachment 9 Contract Drawing List A00008

View the file

Other files

File Type Posted
Section_J _Attachment_4 _References_A00016.pdf PDF
SF30_A00016.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00016.xls XLS spreadsheet
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00015.xls XLS spreadsheet
Section_J _Attachment_3 _CDRL_A00015.pdf PDF
A00015.pdf PDF
A00014_SF30_signed.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00014.xls XLS spreadsheet
Section_J _Attachment_3 _CDRL_A00013.pdf PDF
Section_H_FRC_Phase_II_A00013.pdf PDF
Section_F_FRC_Phase_II_A00013.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00013.xls XLS spreadsheet
A00013_SF30.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00012.xls XLS spreadsheet
Section_J_Attachment_3_CDRL_A00012.pdf PDF
A00012_SF30_signed.pdf PDF
Section_J _Attachment_4 _References_A00011.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00011.xls XLS spreadsheet
Signed_SF30_A00011.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII_A00010.xls XLS spreadsheet
SF30_A00010.pdf PDF
SF30_A00009_signed.pdf PDF
Section_J _Attachment_4 _References_A00009.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
SF_30_A00008_signed.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
Section_J _Attachment_4 _References_A00007.pdf PDF
Section_E_FRC_Phase_II_A00007.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
SF30_A00007_signed.pdf PDF
Section_I_FRC_Phase_II_A00007.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
Section_L_FRC_Phase_II_A00006.pdf PDF
SF_30_A00006.pdf PDF
Section_J _Attachment_7 _GFE_A00005.pdf PDF
Section_J_Attachment_9_Contract_Drawing_List_A00005.xlsx XLSX spreadsheet
SF30_A00005.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
FRC_COR_Section400_Phase_II_A00004.pdf PDF
FRC_COR_Section000_Phase_II_A00004.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
SF30_A0004_signed.pdf PDF
Section_L_FRC_Phase_II_A00004.pdf PDF
FRC_COR_Section500_Phase_II_A00004.pdf PDF
A00003_SF30.pdf PDF
FRC_COR_Section600_Phase_II_A00003.pdf PDF
Question_and_Answer_Report_HSCG23_15_R_FRCPII.xls XLS spreadsheet
Section_J _Attachment_4 _References_A00003.pdf PDF
Section_J _Attachment_9 _Contract_Drawing_List _A00003.pdf PDF
Section_L_FRC_Phase_II_A00002.pdf PDF
Show 40 more

Latest 50 of 88 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Item

Number Drawing Number System / Artifact

Corresponding

CDRL #

A9.1 154R‐WPC‐085‐301 Rev A Hull Lines And Offsets 085‐020

A9.2 154R‐WPC‐111‐301 Shell Expansion 085‐100

A9.3 154R‐WPC‐116‐301 Scantlings ‐ Profile 085‐100

A9.4 154R‐WPC‐122‐301 Watertight Bhds And Transverse Frames 085‐100

A9.5 154R‐WPC‐131‐301 Scantlings ‐ Main Deck 085‐100

A9.6 154R‐WPC‐151‐301 Scantlings‐Superstructure 085‐100

A9.7 154R‐WPC‐200‐301 Machinery Arrangement Drawings 085‐200

A9.8 154R‐WPC‐202‐301 MCMS Cable Block Diagram 085‐201

A9.9 154R‐WPC‐202‐302 MCMS I/O Schedule 085‐201

A9.10 154R‐WPC‐243‐201 Main Propulsion Shafting A&D 085‐202

A9.11 154R‐WPC‐245‐304 Propeller Plans And Data Six Blade Propeller 085‐203

A9.12 154R‐WPC‐245‐305 Propeller 3‐Dimensional Model Six Blade Propeller 245‐001

A9.13 154R‐WPC‐251‐001 Combustion Air Diagram 085‐500

A9.14 154R‐WPC‐252‐301 Propulsion Control System 085‐201

A9.15 154R‐WPC‐256‐301 Main And Auxiliary Cooling System Diagram 085‐500

A9.16 154R‐WPC‐259‐001 Exhaust Piping system Diagram 085‐500

A9.17 154R‐WPC‐310‐301 Electrical One Line Diagram 085‐300

A9.18 154R‐WPC‐320‐301 450V System Deck Plan 085‐301

A9.19 154R‐WPC‐324‐301 Rev A Generator And Switchboard Drawing 085‐302

A9.20 154R‐WPC‐400‐301 C4ISR Space Arrangement 085‐400

A9.21 154R‐WPC‐410‐301 Command And Control Arrangements 085‐400

A9.22 154R‐WPC‐506‐301 Fills, Vents, Sounds and Overflows Diagram 085‐500

A9.23 154R‐WPC‐513‐301 Machinery Ventilation Diagram 085‐500

A9.24 154R‐WPC‐521‐301 Firemain System & Magazine Sprinkler Diagram 085‐500

A9.25 154R‐WPC‐526‐301 Weather Deck Drain Diagram 085‐500

A9.26 154R‐WPC‐528‐301 Grey Water System Diagram 085‐500

A9.27 154R‐WPC‐529‐301 Bilge System Diagram 085‐500

A9.28 154R‐WPC‐533‐301 Potable Water System Diagram 085‐500

A9.29 154R‐WPC‐540‐301 Rev A Lube Oil Service and Transfer System Diagram 085‐500

A9.30 154R‐WPC‐541‐301 Fuel Oil Service And Transfer System Diagram 085‐500

A9.31 154R‐WPC‐551‐301 Compressed Air System Diagram 085‐500

A9.32 154R‐WPC‐555‐301 Rev A Fixed Fire Extinguishing System Diagram 085‐500

A9.33 154R‐WPC‐556‐301 Cutter Boat Launch & Recovery Hydraulic System Diagram 085‐500

A9.34 154R‐WPC‐556‐302 Fin Stabilizer Hydraulic System Diagram 085‐500

A9.35 154R‐WPC‐556‐303 Steering System Hydraulic Diagram 085‐500

A9.36 154R‐WPC‐562‐201 Rudder Details 085‐101

A9.37 154R‐WPC‐562‐202 Rev A Rudder Arrangment & Details 085‐101

A9.38 154R‐WPC‐562‐402 Rudder Arrangement and Details Supporting Design Documentation 085‐101

A9.39 154R‐WPC‐565‐201 Fin Stabilizer System A&D 085‐101

A9.40 154R‐WPC‐582‐201 Mooring and Towing A&D 085‐506

A9.41 154R‐WPC‐583‐201 Cutter Boat Handling And Stowage A&D 085‐600

A9.42 154R‐WPC‐593‐301 Sewage System Diagram 085‐500

A9.43 154R‐WPC‐593‐302 Oily Bilge System Diagram 085‐500

A9.44 154R‐WPC‐601‐302 Rev A General Arrangement 085‐002

A9.45 154R‐WPC‐610‐201 Rev A Life Saving Equipment A&D 085‐603

A9.46 154R‐WPC‐610‐301 Fire Control Plan 085‐603

A9.47 154R‐WPC‐640‐201 Rev A Living Compartments And Arrangements 085‐607

A9.48 154R‐WPC‐700‐301 Rev A Machine Gun Control System 085‐303

Part III ‐ List of Documents, Exhibits, and Other Attachments

Section J, Attachment 9: Contract Drawing List

Item Number Drawing Title Drawing Number Exception Notes

A9.1 Hull Lines And Offsets 154R‐WPC‐085‐301 Rev A 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.2 Shell Expansion 154R‐WPC‐111‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.3 Scantlings ‐ Profile 154R‐WPC‐116‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.4 Watertight Bhds And Transverse

Frames

154R‐WPC‐122‐301

1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.5 Scantlings ‐ Main Deck 154R‐WPC‐131‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.6 Scantlings‐Superstructure 154R‐WPC‐151‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]

A9.7 Machinery Arrangement Drawings 154R‐WPC‐200‐301

1. The location shown for machinery and equipment is approximate.

Offerors may relocate machinery and equipment associated with non‐ standardized systems as long as the new location meets the requirements of the contract.

A9.8 MCMS Cable Block Diagram 154R‐WPC‐202‐301

1. Non‐MTU Manufacturer and Model numbers identified in the

Materials List or throughout the drawing are provided for informational purpose only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. [A00005]

A9.9 MCMS I/O Schedule 154R‐WPC‐202‐302 1. No exceptions. [A00005]

A9.10 Main Propulsion Shafting A&D 154R‐WPC‐243‐201

1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only.

Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Propulsion Shaft installation and Removal Instructions are for

Informational Purposes Only.

3. Bearing Installation and Removal Procedures are for Informational

Purposes Only.

4. General Notes are for Informational Purposes Only.

5. Shaft Seal Installation and Removal Instructions are for

Informational Purposes Only.

6. Arrangements and Details are for Informational Purposes Only.

A9.11 Propeller Plans And Data Six Blade

Propeller

154R‐WPC‐245‐304

1. General Note 5 – “ISO 48412” should be “ISO 484/2”

A9.12 Propeller 3‐Dimensional Model Six

Blade Propeller

154R‐WPC‐245‐305

1. No exceptions

A9.13 Combustion Air Diagram 154R‐WPC‐251‐001

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.14 Propulsion Control System 154R‐WPC‐252‐301 1. No exceptions

A9.15 Main And Auxiliary Cooling System

Diagram

154R‐WPC‐256‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Pipe sizes and fluid flow rates are provided for Informational

Purposes Only.

A9.16 Exhaust Piping system Diagram 154R‐WPC‐259‐001 1. No exceptions

A9.17 Electrical One Line Diagram 154R‐WPC‐310‐301

1. The Shore Power Cable and Connectors (Russelstoll/Meltric) shown in zones 10‐H and 15‐H may be substituted by other brands of cable/connectors meeting the requirements of the contract.

2. The Gaylord brand hood shown in zones 24‐F and 41‐E may be substituted by another brand of fire suppression system hood meeting the requirements of the contract.

3. The dishwasher shown in zone 24‐G has been revised to an 8.2KW model

Contract Drawing Exceptions

A9.18 450V System Deck Plan 154R‐WPC‐320‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Note 8 – Delete the sentences containing “Actual routing of cables is to be as per Ref‐3. Any cables not shown on Ref‐3 are to be field run”.

And add "The contractor is required to define their cable routing scheme in the appropriate reference(s)."

3. The Gaylord system referenced in zone 24‐G may be substituted by another brand of fire suppression system meeting the requirements of the contract.

A9.19 Generator And Switchboard Drawing 154R‐WPC‐324‐301 Rev A

1. No exceptions

A9.20 C4ISR Space Arrangement 154R‐WPC‐400‐301 1. No exceptions

A9.21 Command And Control

Arrangements

154R‐WPC‐410‐301

1. L‐3 Consoles as identified in Materials List items 1‐4 may be substituted by other brands of consoles meeting the requirements of the contract.

2. Locations of equipment/displays within the console are to remain as shown.

A9.22 Fills, Vents, Sounds and Overflows

Diagram

154R‐WPC‐506‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.23 Machinery Ventilation Diagram 154R‐WPC‐513‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Air flow rates are provided for Informational Purposes Only.

A9.24 Firemain System & Magazine

Sprinkler Diagram

154R‐WPC‐521‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.25 Weather Deck Drain Diagram 154R‐WPC‐526‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.26 Grey Water System Diagram 154R‐WPC‐528‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.27 Bilge System Diagram 154R‐WPC‐529‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.28 Potable Water System Diagram 154R‐WPC‐533‐301

1. With the exception of P‐1(Reverse Osmosis Unit), Manufacturer and

Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Change flow rate in General Note #17 from 0.5 GPM to 1.0 GPM.

3. Delete General Note #22.

A9.29 Lube Oil Service and Transfer System

Diagram 154R‐WPC‐540‐301 Rev A

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.30 Fuel Oil Service And Transfer System

Diagram

154R‐WPC‐541‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.31 Compressed Air System Diagram 154R‐WPC‐551‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.32 Fixed Fire Extinguishing System

Diagram 154R‐WPC‐555‐301 Rev A

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. Sheet 5. The Gaylord system may be substituted by another brand of fire suppression system meeting the requirements of the contract.

A9.33 Cutter Boat Launch & Recovery

Hydraulic System Diagram

154R‐WPC‐556‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.34 Fin Stabilizer Hydraulic System

Diagram

154R‐WPC‐556‐302

1. No exceptions

A9.35 Steering System Hydraulic Diagram 154R‐WPC‐556‐303

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.36 Rudder Details 154R‐WPC‐562‐201 1. No exceptions

A9.37 Rudder Arrangment & Details 154R‐WPC‐562‐202 Rev A 1. No exceptions

A9.38 Rudder Arrangement and Details

Supporting Design Documentation

154R‐WPC‐562‐402

1. No exceptions

A9.39 Fin Stabilizer System A&D 154R‐WPC‐565‐201 1. No exceptions

A9.40 Mooring and Towing A&D 154R‐WPC‐582‐201

1. PN‐18(Hydraulic Winch), PN‐25 (Swivel Hook) and PN‐40 (Spring

Extension Hook Ends) may be substituted by other brands of this equipment/hardware meeting the requirements of the contract.

A9.41 Cutter Boat Handling And Stowage

A&D

154R‐WPC‐583‐201

1. For purposes of this drawing the Naiad Cutter Boat shown and the

Cutter Boat Over‐the‐Horizon IV designated in the contract are interchangeable.

2.Material List items 1‐14, 17‐23, and 36‐44 are provided for

Informational Purposes Only and may be substituted by other brands of this equipment/hardware meeting the requirements of the contract.

A9.42 Sewage System Diagram 154R‐WPC‐593‐301

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.43 Oily Bilge System Diagram 154R‐WPC‐593‐302

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.44 General Arrangement 154R‐WPC‐601‐302 Rev A

1. The location of furniture and outfitting items are approximate.

2. The Vidmar brand cabinet shown in zone 27‐B may be substituted by another brand of locker meeting the requirements of the contract.

3. The 7.9M NAIAD RIB shown in zone 31‐E has been replaced by the

Standardized Cutter Boat Over‐the‐Horizon IV per requirement of the contract.

A9.45 Life Saving Equipment A&D 154R‐WPC‐610‐201 Rev A

1. Manufacturer and Model Numbers identified in the Equipment

Parts List or throughout the drawing are provided for Informational

Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

2. For General Notes 4, 5 and 6, the word “will” shall be replaced by the word “shall”.

3. The 7.9M NAIAD RIB shown in zone 31‐E has been replaced by the

Standardized Cutter Boat Over‐the‐Horizon IV per requirement of the contract.

A9.46 Fire Control Plan 154R‐WPC‐610‐301 1. No exceptions

A9.47 Living Compartments And

Arrangements 154R‐WPC‐640‐201 Rev A

1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only.

Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.

A9.48 Machine Gun Control System 154R‐WPC‐700‐301 Rev A 1. No exceptions

Section J, Attachment 9, Contract Drawing List, RFP_A00008.pdf
Section J, Attachment 9, Contract Drawing List, RFP_A00008.pdf

File details come from the government source that posted it. Updated .