Section_J _Attachment_9 _Contract_Drawing_List _RFP_A00008.pdf
PDF 105 KB Posted
- Attached to
- United States Coast Guard Phase II Fast Response Cutter (FRC) Request for Proposals (RFP)
- Solicitation number
- HSCG23-15-R-FRCPII
About this file
Section J Attachment 9 Contract Drawing List A00008
View the file
Other files
Show 40 more
Latest 50 of 88 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Item
Number Drawing Number System / Artifact
Corresponding
CDRL #
A9.1 154R‐WPC‐085‐301 Rev A Hull Lines And Offsets 085‐020
A9.2 154R‐WPC‐111‐301 Shell Expansion 085‐100
A9.3 154R‐WPC‐116‐301 Scantlings ‐ Profile 085‐100
A9.4 154R‐WPC‐122‐301 Watertight Bhds And Transverse Frames 085‐100
A9.5 154R‐WPC‐131‐301 Scantlings ‐ Main Deck 085‐100
A9.6 154R‐WPC‐151‐301 Scantlings‐Superstructure 085‐100
A9.7 154R‐WPC‐200‐301 Machinery Arrangement Drawings 085‐200
A9.8 154R‐WPC‐202‐301 MCMS Cable Block Diagram 085‐201
A9.9 154R‐WPC‐202‐302 MCMS I/O Schedule 085‐201
A9.10 154R‐WPC‐243‐201 Main Propulsion Shafting A&D 085‐202
A9.11 154R‐WPC‐245‐304 Propeller Plans And Data Six Blade Propeller 085‐203
A9.12 154R‐WPC‐245‐305 Propeller 3‐Dimensional Model Six Blade Propeller 245‐001
A9.13 154R‐WPC‐251‐001 Combustion Air Diagram 085‐500
A9.14 154R‐WPC‐252‐301 Propulsion Control System 085‐201
A9.15 154R‐WPC‐256‐301 Main And Auxiliary Cooling System Diagram 085‐500
A9.16 154R‐WPC‐259‐001 Exhaust Piping system Diagram 085‐500
A9.17 154R‐WPC‐310‐301 Electrical One Line Diagram 085‐300
A9.18 154R‐WPC‐320‐301 450V System Deck Plan 085‐301
A9.19 154R‐WPC‐324‐301 Rev A Generator And Switchboard Drawing 085‐302
A9.20 154R‐WPC‐400‐301 C4ISR Space Arrangement 085‐400
A9.21 154R‐WPC‐410‐301 Command And Control Arrangements 085‐400
A9.22 154R‐WPC‐506‐301 Fills, Vents, Sounds and Overflows Diagram 085‐500
A9.23 154R‐WPC‐513‐301 Machinery Ventilation Diagram 085‐500
A9.24 154R‐WPC‐521‐301 Firemain System & Magazine Sprinkler Diagram 085‐500
A9.25 154R‐WPC‐526‐301 Weather Deck Drain Diagram 085‐500
A9.26 154R‐WPC‐528‐301 Grey Water System Diagram 085‐500
A9.27 154R‐WPC‐529‐301 Bilge System Diagram 085‐500
A9.28 154R‐WPC‐533‐301 Potable Water System Diagram 085‐500
A9.29 154R‐WPC‐540‐301 Rev A Lube Oil Service and Transfer System Diagram 085‐500
A9.30 154R‐WPC‐541‐301 Fuel Oil Service And Transfer System Diagram 085‐500
A9.31 154R‐WPC‐551‐301 Compressed Air System Diagram 085‐500
A9.32 154R‐WPC‐555‐301 Rev A Fixed Fire Extinguishing System Diagram 085‐500
A9.33 154R‐WPC‐556‐301 Cutter Boat Launch & Recovery Hydraulic System Diagram 085‐500
A9.34 154R‐WPC‐556‐302 Fin Stabilizer Hydraulic System Diagram 085‐500
A9.35 154R‐WPC‐556‐303 Steering System Hydraulic Diagram 085‐500
A9.36 154R‐WPC‐562‐201 Rudder Details 085‐101
A9.37 154R‐WPC‐562‐202 Rev A Rudder Arrangment & Details 085‐101
A9.38 154R‐WPC‐562‐402 Rudder Arrangement and Details Supporting Design Documentation 085‐101
A9.39 154R‐WPC‐565‐201 Fin Stabilizer System A&D 085‐101
A9.40 154R‐WPC‐582‐201 Mooring and Towing A&D 085‐506
A9.41 154R‐WPC‐583‐201 Cutter Boat Handling And Stowage A&D 085‐600
A9.42 154R‐WPC‐593‐301 Sewage System Diagram 085‐500
A9.43 154R‐WPC‐593‐302 Oily Bilge System Diagram 085‐500
A9.44 154R‐WPC‐601‐302 Rev A General Arrangement 085‐002
A9.45 154R‐WPC‐610‐201 Rev A Life Saving Equipment A&D 085‐603
A9.46 154R‐WPC‐610‐301 Fire Control Plan 085‐603
A9.47 154R‐WPC‐640‐201 Rev A Living Compartments And Arrangements 085‐607
A9.48 154R‐WPC‐700‐301 Rev A Machine Gun Control System 085‐303
Part III ‐ List of Documents, Exhibits, and Other Attachments
Section J, Attachment 9: Contract Drawing List
Item Number Drawing Title Drawing Number Exception Notes
A9.1 Hull Lines And Offsets 154R‐WPC‐085‐301 Rev A 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.2 Shell Expansion 154R‐WPC‐111‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.3 Scantlings ‐ Profile 154R‐WPC‐116‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.4 Watertight Bhds And Transverse
Frames
154R‐WPC‐122‐301
1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.5 Scantlings ‐ Main Deck 154R‐WPC‐131‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.6 Scantlings‐Superstructure 154R‐WPC‐151‐301 1. Only exceptions as noted in COR Section 100‐1.3 [A00008]
A9.7 Machinery Arrangement Drawings 154R‐WPC‐200‐301
1. The location shown for machinery and equipment is approximate.
Offerors may relocate machinery and equipment associated with non‐ standardized systems as long as the new location meets the requirements of the contract.
A9.8 MCMS Cable Block Diagram 154R‐WPC‐202‐301
1. Non‐MTU Manufacturer and Model numbers identified in the
Materials List or throughout the drawing are provided for informational purpose only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. [A00005]
A9.9 MCMS I/O Schedule 154R‐WPC‐202‐302 1. No exceptions. [A00005]
A9.10 Main Propulsion Shafting A&D 154R‐WPC‐243‐201
1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only.
Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Propulsion Shaft installation and Removal Instructions are for
Informational Purposes Only.
3. Bearing Installation and Removal Procedures are for Informational
Purposes Only.
4. General Notes are for Informational Purposes Only.
5. Shaft Seal Installation and Removal Instructions are for
Informational Purposes Only.
6. Arrangements and Details are for Informational Purposes Only.
A9.11 Propeller Plans And Data Six Blade
Propeller
154R‐WPC‐245‐304
1. General Note 5 – “ISO 48412” should be “ISO 484/2”
A9.12 Propeller 3‐Dimensional Model Six
Blade Propeller
154R‐WPC‐245‐305
1. No exceptions
A9.13 Combustion Air Diagram 154R‐WPC‐251‐001
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.14 Propulsion Control System 154R‐WPC‐252‐301 1. No exceptions
A9.15 Main And Auxiliary Cooling System
Diagram
154R‐WPC‐256‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Pipe sizes and fluid flow rates are provided for Informational
Purposes Only.
A9.16 Exhaust Piping system Diagram 154R‐WPC‐259‐001 1. No exceptions
A9.17 Electrical One Line Diagram 154R‐WPC‐310‐301
1. The Shore Power Cable and Connectors (Russelstoll/Meltric) shown in zones 10‐H and 15‐H may be substituted by other brands of cable/connectors meeting the requirements of the contract.
2. The Gaylord brand hood shown in zones 24‐F and 41‐E may be substituted by another brand of fire suppression system hood meeting the requirements of the contract.
3. The dishwasher shown in zone 24‐G has been revised to an 8.2KW model
Contract Drawing Exceptions
A9.18 450V System Deck Plan 154R‐WPC‐320‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Note 8 – Delete the sentences containing “Actual routing of cables is to be as per Ref‐3. Any cables not shown on Ref‐3 are to be field run”.
And add "The contractor is required to define their cable routing scheme in the appropriate reference(s)."
3. The Gaylord system referenced in zone 24‐G may be substituted by another brand of fire suppression system meeting the requirements of the contract.
A9.19 Generator And Switchboard Drawing 154R‐WPC‐324‐301 Rev A
1. No exceptions
A9.20 C4ISR Space Arrangement 154R‐WPC‐400‐301 1. No exceptions
A9.21 Command And Control
Arrangements
154R‐WPC‐410‐301
1. L‐3 Consoles as identified in Materials List items 1‐4 may be substituted by other brands of consoles meeting the requirements of the contract.
2. Locations of equipment/displays within the console are to remain as shown.
A9.22 Fills, Vents, Sounds and Overflows
Diagram
154R‐WPC‐506‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.23 Machinery Ventilation Diagram 154R‐WPC‐513‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Air flow rates are provided for Informational Purposes Only.
A9.24 Firemain System & Magazine
Sprinkler Diagram
154R‐WPC‐521‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.25 Weather Deck Drain Diagram 154R‐WPC‐526‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.26 Grey Water System Diagram 154R‐WPC‐528‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.27 Bilge System Diagram 154R‐WPC‐529‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.28 Potable Water System Diagram 154R‐WPC‐533‐301
1. With the exception of P‐1(Reverse Osmosis Unit), Manufacturer and
Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Change flow rate in General Note #17 from 0.5 GPM to 1.0 GPM.
3. Delete General Note #22.
A9.29 Lube Oil Service and Transfer System
Diagram 154R‐WPC‐540‐301 Rev A
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.30 Fuel Oil Service And Transfer System
Diagram
154R‐WPC‐541‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.31 Compressed Air System Diagram 154R‐WPC‐551‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.32 Fixed Fire Extinguishing System
Diagram 154R‐WPC‐555‐301 Rev A
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Sheet 5. The Gaylord system may be substituted by another brand of fire suppression system meeting the requirements of the contract.
A9.33 Cutter Boat Launch & Recovery
Hydraulic System Diagram
154R‐WPC‐556‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.34 Fin Stabilizer Hydraulic System
Diagram
154R‐WPC‐556‐302
1. No exceptions
A9.35 Steering System Hydraulic Diagram 154R‐WPC‐556‐303
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.36 Rudder Details 154R‐WPC‐562‐201 1. No exceptions
A9.37 Rudder Arrangment & Details 154R‐WPC‐562‐202 Rev A 1. No exceptions
A9.38 Rudder Arrangement and Details
Supporting Design Documentation
154R‐WPC‐562‐402
1. No exceptions
A9.39 Fin Stabilizer System A&D 154R‐WPC‐565‐201 1. No exceptions
A9.40 Mooring and Towing A&D 154R‐WPC‐582‐201
1. PN‐18(Hydraulic Winch), PN‐25 (Swivel Hook) and PN‐40 (Spring
Extension Hook Ends) may be substituted by other brands of this equipment/hardware meeting the requirements of the contract.
A9.41 Cutter Boat Handling And Stowage
A&D
154R‐WPC‐583‐201
1. For purposes of this drawing the Naiad Cutter Boat shown and the
Cutter Boat Over‐the‐Horizon IV designated in the contract are interchangeable.
2.Material List items 1‐14, 17‐23, and 36‐44 are provided for
Informational Purposes Only and may be substituted by other brands of this equipment/hardware meeting the requirements of the contract.
A9.42 Sewage System Diagram 154R‐WPC‐593‐301
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.43 Oily Bilge System Diagram 154R‐WPC‐593‐302
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.44 General Arrangement 154R‐WPC‐601‐302 Rev A
1. The location of furniture and outfitting items are approximate.
2. The Vidmar brand cabinet shown in zone 27‐B may be substituted by another brand of locker meeting the requirements of the contract.
3. The 7.9M NAIAD RIB shown in zone 31‐E has been replaced by the
Standardized Cutter Boat Over‐the‐Horizon IV per requirement of the contract.
A9.45 Life Saving Equipment A&D 154R‐WPC‐610‐201 Rev A
1. Manufacturer and Model Numbers identified in the Equipment
Parts List or throughout the drawing are provided for Informational
Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. For General Notes 4, 5 and 6, the word “will” shall be replaced by the word “shall”.
3. The 7.9M NAIAD RIB shown in zone 31‐E has been replaced by the
Standardized Cutter Boat Over‐the‐Horizon IV per requirement of the contract.
A9.46 Fire Control Plan 154R‐WPC‐610‐301 1. No exceptions
A9.47 Living Compartments And
Arrangements 154R‐WPC‐640‐201 Rev A
1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only.
Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
A9.48 Machine Gun Control System 154R‐WPC‐700‐301 Rev A 1. No exceptions
| Section J, Attachment 9, Contract Drawing List, RFP_A00008.pdf |
| Section J, Attachment 9, Contract Drawing List, RFP_A00008.pdf |
File details come from the government source that posted it. Updated .