Section_J_Attachment_9_Contract_Drawing_List_A00005.xlsx
XLSX spreadsheet 32 KB Posted
- Attached to
- United States Coast Guard Phase II Fast Response Cutter (FRC) Request for Proposals (RFP)
- Solicitation number
- HSCG23-15-R-FRCPII
About this file
Section J Attachment 9 Exceptions List
View the file
Other files
Show 40 more
Latest 50 of 88 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Contract Drawing List Part III - List of Documents, Exhibits, and Other Attachments Section J, Attachment 9: Contract Drawing List
| Item Number | Drawing Number | System / Artifact | Corresponding CDRL # |
| A9.1 | 154R-WPC-085-301 Rev A | Hull Lines And Offsets | 085-020 |
| A9.2 | 154R-WPC-111-301 | Shell Expansion | 085-100 |
| A9.3 | 154R-WPC-116-301 | Scantlings - Profile | 085-100 |
| A9.4 | 154R-WPC-122-301 | Watertight Bhds And Transverse Frames | 085-100 |
| A9.5 | 154R-WPC-131-301 | Scantlings - Main Deck | 085-100 |
| A9.6 | 154R-WPC-151-301 | Scantlings-Superstructure | 085-100 |
| A9.7 | 154R-WPC-200-301 | Machinery Arrangement Drawings | 085-200 |
| A9.8 | 154R-WPC-202-301 | MCMS Cable Block Diagram | 085-201 |
| A9.9 | 154R-WPC-202-302 | MCMS I/O Schedule | 085-201 |
| A9.10 | 154R-WPC-243-201 | Main Propulsion Shafting A&D | 085-202 |
| A9.11 | 154R-WPC-245-304 | Propeller Plans And Data Six Blade Propeller | 085-203 |
| A9.12 | 154R-WPC-245-305 | Propeller 3-Dimensional Model Six Blade Propeller | 245-001 |
| A9.13 | 154R-WPC-251-001 | Combustion Air Diagram | 085-500 |
| A9.14 | 154R-WPC-252-301 | Propulsion Control System | 085-201 |
| A9.15 | 154R-WPC-256-301 | Main And Auxiliary Cooling System Diagram | 085-500 |
| A9.16 | 154R-WPC-259-001 | Exhaust Piping system Diagram | 085-500 |
| A9.17 | 154R-WPC-310-301 | Electrical One Line Diagram | 085-300 |
| A9.18 | 154R-WPC-320-301 | 450V System Deck Plan | 085-301 |
| A9.19 | 154R-WPC-324-301 Rev A | Generator And Switchboard Drawing | 085-302 |
| A9.20 | 154R-WPC-400-301 | C4ISR Space Arrangement | 085-400 |
| A9.21 | 154R-WPC-410-301 | Command And Control Arrangements | 085-400 |
| A9.22 | 154R-WPC-506-301 | Fills, Vents, Sounds and Overflows Diagram | 085-500 |
| A9.23 | 154R-WPC-513-301 | Machinery Ventilation Diagram | 085-500 |
| A9.24 | 154R-WPC-521-301 | Firemain System & Magazine Sprinkler Diagram | 085-500 |
| A9.25 | 154R-WPC-526-301 | Weather Deck Drain Diagram | 085-500 |
| A9.26 | 154R-WPC-528-301 | Grey Water System Diagram | 085-500 |
| A9.27 | 154R-WPC-529-301 | Bilge System Diagram | 085-500 |
| A9.28 | 154R-WPC-533-301 | Potable Water System Diagram | 085-500 |
| A9.29 | 154R-WPC-540-301 Rev A | Lube Oil Service and Transfer System Diagram | 085-500 |
| A9.30 | 154R-WPC-541-301 | Fuel Oil Service And Transfer System Diagram | 085-500 |
| A9.31 | 154R-WPC-551-301 | Compressed Air System Diagram | 085-500 |
| A9.32 | 154R-WPC-555-301 Rev A | Fixed Fire Extinguishing System Diagram | 085-500 |
| A9.33 | 154R-WPC-556-301 | Cutter Boat Launch & Recovery Hydraulic System Diagram | 085-500 |
| A9.34 | 154R-WPC-556-302 | Fin Stabilizer Hydraulic System Diagram | 085-500 |
| A9.35 | 154R-WPC-556-303 | Steering System Hydraulic Diagram | 085-500 |
| A9.36 | 154R-WPC-562-201 | Rudder Details | 085-101 |
| A9.37 | 154R-WPC-562-202 Rev A | Rudder Arrangment & Details | 085-101 |
| A9.38 | 154R-WPC-562-402 | Rudder Arrangement and Details Supporting Design Documentation | 085-101 |
| A9.39 | 154R-WPC-565-201 | Fin Stabilizer System A&D | 085-101 |
| A9.40 | 154R-WPC-582-201 | Mooring and Towing A&D | 085-506 |
| A9.41 | 154R-WPC-583-201 | Cutter Boat Handling And Stowage A&D | 085-600 |
| A9.42 | 154R-WPC-593-301 | Sewage System Diagram | 085-500 |
| A9.43 | 154R-WPC-593-302 | Oily Bilge System Diagram | 085-500 |
| A9.44 | 154R-WPC-601-302 Rev A | General Arrangement | 085-002 |
| A9.45 | 154R-WPC-610-201 Rev A | Life Saving Equipment A&D | 085-603 |
| A9.46 | 154R-WPC-610-301 | Fire Control Plan | 085-603 |
| A9.47 | 154R-WPC-640-201 Rev A | Living Compartments And Arrangements | 085-607 |
| A9.48 | 154R-WPC-700-301 Rev A | Machine Gun Control System | 085-303 |
Contract Drawing Exceptions
| Contract Drawing Exceptions | |||
| Item Number | Drawing Title | Drawing Number | Exception Notes |
| A9.1 | Hull Lines And Offsets | 154R-WPC-085-301 Rev A | 1. No exceptions |
| A9.2 | Shell Expansion | 154R-WPC-111-301 | 1. No exceptions |
| A9.3 | Scantlings - Profile | 154R-WPC-116-301 | 1. No exceptions |
| A9.4 | Watertight Bhds And Transverse Frames | 154R-WPC-122-301 | 1. No exceptions |
| A9.5 | Scantlings - Main Deck | 154R-WPC-131-301 | 1. No exceptions |
| A9.6 | Scantlings-Superstructure | 154R-WPC-151-301 | 1. No exceptions |
| A9.7 | Machinery Arrangement Drawings | 154R-WPC-200-301 | 1. The location shown for machinery and equipment is approximate. Offerors may relocate machinery and equipment associated with non-standardized systems as long as the new location meets the requirements of the contract. |
| A9.8 | MCMS Cable Block Diagram | 154R-WPC-202-301 | 1. Non-MTU Manufacturer and Model numbers identified in the Materials List or throughout the drawing are provided for informational purpose only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. [A00005] |
| A9.9 | MCMS I/O Schedule | 154R-WPC-202-302 | 1. No exceptions. [A00005] |
| A9.10 | Main Propulsion Shafting A&D | 154R-WPC-243-201 | 1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
2. Propulsion Shaft installation and Removal Instructions are for Informational Purposes Only.
3. Bearing Installation and Removal Procedures are for Informational Purposes Only.
4. General Notes are for Informational Purposes Only.
5. Shaft Seal Installation and Removal Instructions are for Informational Purposes Only.
6. Arrangements and Details are for Informational Purposes Only.
| A9.11 | Propeller Plans And Data Six Blade Propeller | 154R-WPC-245-304 | 1. General Note 5 – “ISO 48412” should be “ISO 484/2” |
| A9.12 | Propeller 3-Dimensional Model Six Blade Propeller | 154R-WPC-245-305 | 1. No exceptions |
| A9.13 | Combustion Air Diagram | 154R-WPC-251-001 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.14 | Propulsion Control System | 154R-WPC-252-301 | 1. No exceptions |
| A9.15 | Main And Auxiliary Cooling System Diagram | 154R-WPC-256-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
2. Pipe sizes and fluid flow rates are provided for Informational Purposes Only.
| A9.16 | Exhaust Piping system Diagram | 154R-WPC-259-001 | 1. No exceptions |
| A9.17 | Electrical One Line Diagram | 154R-WPC-310-301 | 1. The Shore Power Cable and Connectors (Russelstoll/Meltric) shown in zones 10-H and 15-H may be substituted by other brands of cable/connectors meeting the requirements of the contract. |
2. The Gaylord brand hood shown in zones 24-F and 41-E may be substituted by another brand of fire suppression system hood meeting the requirements of the contract.
3. The dishwasher shown in zone 24-G has been revised to an 8.2KW model A9.18 450V System Deck Plan 154R-WPC-320-301 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. Note 8 – Delete the sentences containing “Actual routing of cables is to be as per Ref-3. Any cables not shown on Ref-3 are to be field run”. And add "The contractor is required to define their cable routing scheme in the appropriate reference(s)."
3. The Gaylord system referenced in zone 24-G may be substituted by another brand of fire suppression system meeting the requirements of the contract.
| A9.19 | Generator And Switchboard Drawing | 154R-WPC-324-301 Rev A | 1. No exceptions |
| A9.20 | C4ISR Space Arrangement | 154R-WPC-400-301 | 1. No exceptions |
| A9.21 | Command And Control Arrangements | 154R-WPC-410-301 | 1. L-3 Consoles as identified in Materials List items 1-4 may be substituted by other brands of consoles meeting the requirements of the contract. |
2. Locations of equipment/displays within the console are to remain as shown.
| A9.22 | Fills, Vents, Sounds and Overflows Diagram | 154R-WPC-506-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.23 | Machinery Ventilation Diagram | 154R-WPC-513-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
2. Air flow rates are provided for Informational Purposes Only.
| A9.24 | Firemain System & Magazine Sprinkler Diagram | 154R-WPC-521-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.25 | Weather Deck Drain Diagram | 154R-WPC-526-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.26 | Grey Water System Diagram | 154R-WPC-528-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.27 | Bilge System Diagram | 154R-WPC-529-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.28 | Potable Water System Diagram | 154R-WPC-533-301 | 1. With the exception of P-1(Reverse Osmosis Unit), Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
2. Change flow rate in General Note #17 from 0.5 GPM to 1.0 GPM.
3. Delete General Note #22.
| A9.29 | Lube Oil Service and Transfer System Diagram | 154R-WPC-540-301 Rev A | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.30 | Fuel Oil Service And Transfer System Diagram | 154R-WPC-541-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.31 | Compressed Air System Diagram | 154R-WPC-551-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.32 | Fixed Fire Extinguishing System Diagram | 154R-WPC-555-301 Rev A | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
2. Sheet 5. The Gaylord system may be substituted by another brand of fire suppression system meeting the requirements of the contract.
| A9.33 | Cutter Boat Launch & Recovery Hydraulic System Diagram | 154R-WPC-556-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.34 | Fin Stabilizer Hydraulic System Diagram | 154R-WPC-556-302 | 1. No exceptions |
| A9.35 | Steering System Hydraulic Diagram | 154R-WPC-556-303 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.36 | Rudder Details | 154R-WPC-562-201 | 1. No exceptions |
| A9.37 | Rudder Arrangment & Details | 154R-WPC-562-202 Rev A | 1. No exceptions |
| A9.38 | Rudder Arrangement and Details Supporting Design Documentation | 154R-WPC-562-402 | 1. No exceptions |
| A9.39 | Fin Stabilizer System A&D | 154R-WPC-565-201 | 1. No exceptions |
| A9.40 | Mooring and Towing A&D | 154R-WPC-582-201 | 1. PN-18(Hydraulic Winch), PN-25 (Swivel Hook) and PN-40 (Spring Extension Hook Ends) may be substituted by other brands of this equipment/hardware meeting the requirements of the contract. |
| A9.41 | Cutter Boat Handling And Stowage A&D | 154R-WPC-583-201 | 1. For purposes of this drawing the Naiad Cutter Boat shown and the Cutter Boat Over-the-Horizon IV designated in the contract are interchangeable. |
2.Material List items 1-14, 17-23, and 36-44 are provided for Informational Purposes Only and may be substituted by other brands of this equipment/hardware meeting the requirements of the contract.
| A9.42 | Sewage System Diagram | 154R-WPC-593-301 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.43 | Oily Bilge System Diagram | 154R-WPC-593-302 | 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.44 | General Arrangement | 154R-WPC-601-302 Rev A | 1. The location of furniture and outfitting items are approximate. |
2. The Vidmar brand cabinet shown in zone 27-B may be substituted by another brand of locker meeting the requirements of the contract.
3. The 7.9M NAIAD RIB shown in zone 31-E has been replaced by the Standardized Cutter Boat Over-the-Horizon IV per requirement of the contract.
A9.45 Life Saving Equipment A&D 154R-WPC-610-201 Rev A 1. Manufacturer and Model Numbers identified in the Equipment Parts List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract.
2. For General Notes 4, 5 and 6, the word “will” shall be replaced by the word “shall”.
3. The 7.9M NAIAD RIB shown in zone 31-E has been replaced by the Standardized Cutter Boat Over-the-Horizon IV per requirement of the contract.
| A9.46 | Fire Control Plan | 154R-WPC-610-301 | 1. No exceptions |
| A9.47 | Living Compartments And Arrangements | 154R-WPC-640-201 Rev A | 1. Manufacturer and Model Numbers identified in the Materials List or throughout the drawing are provided for Informational Purposes Only. Offerors may substitute or change manufacturers and model numbers, however any changes shall meet the requirements of the contract. |
| A9.48 | Machine Gun Control System | 154R-WPC-700-301 Rev A | 1. No exceptions |
File details come from the government source that posted it. Updated .