A23 Exhibit G Experience-Offeror (12 Jun 2021).docx
DOCX document 30 KB Posted
- Solicitation number
- HQ003421R0003
- Issued by
-
DOD Washington Headquarters Service
About this file
This solicitation is for the Washington Headquarters Services Acquisition Directorate Multiple Award Construction Contract II program. The requirement is a 100% HUBZone small business set-aside. The indefinite-delivery, indefinite-quantity contracts have a ceiling value of $150 million each over a potential 10 year period and include provisions for on- and off-ramps. The work includes design-build and design-bid-build construction, alteration, and repair projects such as renovation of commercial and industrial buildings, sustainment and modernization of existing facilities, and repair work. Project locations are primarily in the District of Columbia, Maryland, Virginia, and Adams County, Pennsylvania. Task order values are expected to range from $500 thousand to $15 million, with some up to $20 million. The minimum guarantee for each contract is $10,000 for the life of the contract. Responsible certified HUBZone small businesses meeting the stated criteria are encouraged to submit proposals.
View the file
Other files
Show 40 more
Latest 50 of 67 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXHIBIT “G”
CONSTRUCTION EXPERIENCE PROJECT DATA SHEET – OFFEROR
HQ003421R0003
This form is to be completed by the Offeror. Submit (one per project) in order to provide supporting project information for Technical Subfactor 2 Experience. Only projects that are within the project description parameters of the solicitation are considered relevant. Each offeror must submit three (3) projects. No other projects may be considered under the experience factor. Do not exceed three (5) pages per project. The Government will not review any sheets beyond three (5) pages for each project.
Project No. (check one): |_| - 1 |_| - 2 |_| - 3
Design-Build Construction Contractor:
| 1. |
| Offeror Name: |
| Firm who performed the work: |
| Performed this work as: | ||
| |_| Prime Contractor | |_| Subcontractor | |_| Joint Venture |
| |_| Other (explain): |
| If subcontractor, name of prime: |
| Phone #: |
| If the firm who constructed this project differs from the Offeror proposing on this contract, identify the firm’s relationship to the Offeror: |
| |_| Joint Venture Partner |_| Partner |
|_| Subsidiary |_| Parent Company |_| Affiliate |_| Predecessor Company |_| Other:
Explain how this firm will have meaningful involvement in the performance of the contract:
Note: The firm who performed the work of this project must be named and fully described as a team member who will have meaningful involvement in performance of the relevant work of this contract. If the Offeror fails to demonstrate the firm’s meaningful involvement in the performance of this contract, the project will not be considered relevant and will not be evaluated.
Design-Build Construction Contract:
| 2. |
| Contract/Project No.: |
| Delivery/Task Order Number: |
| Title: |
| Location: |
| 3. |
| Award Date (mm/dd/yy): |
| Award Amount: $ |
| Completion Date at NTP (mm/dd/yy): |
| Final Price: $ |
| Actual Completion Date (mm/dd/yy): |
| This is the: |_| total project |_| subcontract price |
Note: If firm is indicated as a subcontractor in Block 1, provide the price of the subcontract.
| ICD/ICS 705 Accredited: |
| |_| Yes |_| No |
Design Firm – Designer of Record:
| 4. |
| Design Firm Name: |
| Design Firm Address: |
Client/Owner Information:
| 5. |
| Client Owner: |
| Point of Contact Name/Title: |
| POC Phone Number: |
| POC Email Address: |
Project Description:
6. This project was primarily (check one box only): |_| New Construction |_| Renovation/Repair
| 7. |
| Type of Facility: |
| 8. |
| Facility Total SF: |
| 9. |
| Construction Area SF: |
| 10. |
| Number of 1st Tier Subcontractors |
| 11. |
| Number of 2nd Tier and Lower Subcontractors: |
| 12. |
| Total Cost of Work Subcontracted by Prime: |
13. Provide a detailed description of the project and the relevancy to the project requirements of this RFP.
14. Describe the scope and extent of design effort required and the relevancy to the project requirements of this RFP.
15. Describe specific prime offeror capabilities effectively demonstrated during design and construction this project that are relevant to the project requirements of this RFP.
16. Describe in detail specific sustainable design features, LEED/USGBC, and/or historic features involved in this project. Attach green building certification(s) received, if any (will not count toward page limitation).
17. Describe in detail specific Building Information Modeling (BIM) element(s) used in the design of this project to produce a complete set of construction documents.
Note: Form may be expanded to maximum of 5 pages.
Exhibit “G” – Project Experience – Offeror and Designer, Page 2 of 2
(Rev 6/21)
File details come from the government source that posted it. Updated .