Fire Pump from WWYK180027.pdf

PDF 151 KB Posted

Attached to
Tinker AFB MAC BOA WWYK230052, Replace Vault and Fuel Tank, B1032
Solicitation number
FA813725R0033
Issued by

About this file

The image appears to be a technical schematic or diagram of a mechanical component, likely a fire pump or valve system. The drawing features a vertical design with multiple interconnected mechanical elements including circular and rectangular shapes, connected by vertical and horizontal lines, suggesting a complex mechanical or hydraulic system configuration.

View the file

Other files

File Type Posted
10 44 16.pdf PDF
33 08 55.pdf PDF
Att12_230052_Submittal Register_r2.pdf PDF
03 39 00.00 10.pdf PDF
03 30 00.pdf PDF
32 13 14.pdf PDF
10_230052_SOW_BWR_Revision_r1.pdf PDF
000_TABLE OF CONTENTS.pdf PDF
03 20 00.00 10.pdf PDF
31 23 16.pdf PDF
32 16 13.pdf PDF
07 92 00.pdf PDF
32 92 19.pdf PDF
33 52 40.pdf PDF
33 52 23.15.pdf PDF
32 31 13.pdf PDF
03 11 13.00 10.pdf PDF
32 11 23.pdf PDF
Att12_230052_Submittal Register_r2.xlsx XLSX spreadsheet
26 05 00.00 40.pdf PDF
32 12 10.1.pdf PDF
31 00 00.pdf PDF
31 23 06.pdf PDF
26 08 00.pdf PDF
26 00 00.00 20.pdf PDF
06 10 00.pdf PDF
33 56 10.pdf PDF
32 01 22.pdf PDF
31 23 15.pdf PDF
32 92 23.pdf PDF
02 41 00.pdf PDF
32 12 10.2.pdf PDF
WWYK230052 RFI responses COR Signed.pdf PDF
Sign-in Sheet WWYK230052 B1132.pdf PDF
Solicitation - FA813725R0033.pdf PDF
Wage Determination.pdf PDF
Att13_230052_Drawings.pdf PDF
Att12_230052_Submittal Register_r1.xlsx XLSX spreadsheet
ENG-34-066-58-75.pdf PDF
2 EAL List - BLANK to Contractors.xlsx XLSX spreadsheet
Att10_230052_SOW_BWR_Revision_24 April.pdf PDF
B1032 from WWYK180027 IFC PLAN SET.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1032-PFW-2 1032-PFW-3 1032-PFW-41032-PFW-1

EX

FACU

XCVR EX

EX

EX

FPC FPC FPC FPC

F I R

E

P

R O

T E

C T

I O

N

FP102

A O

T W

R M

P L

A N

E W

W

O R

K

B U

I L

D I N

G

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

I R

F

R

C

B

S

E

O

K L A

H O

M A

P R

O J E

T

F O

R M

A T

I O

N R

E V

I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

T

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D E

S I G

N

F

I L

L

C A

T I O

N

W W

Y K

R

P

A I R

A N

D

R

E P

L A

R

E

P

U M

P S

V A

R I O

U S

C

I L

I T

I E

S

F

E B

R U

A R

Y

H D

R

FIRE PROTECTION PLAN - NEW WORK - BUILDING 1032

SCALE: 1/4" = 1' - 0"

FP102

KEY NOTES:

PROVIDE A NEW PUMP CONTROLLER, NEW DIESEL DRIVEN FIRE

PUMP ENGINE AND NEW FIRE PUMP, AS DETAILED IN THE FIRE

PUMP AND ENGINE SCHEDULES. FIRE PUMP SHALL HAVE A

MINIMUM OPERATING PRESSURE OF 125 PSI.

REINSTALL FIRE PUMP SUPERVISION INTERFACE AND CONDUIT

TO FIRE ALARM SYSTEM. FIRE PUMP SUPERVISION INTERFACE

SHALL BE TESTED AT OF PROJECT. FIRE ALARM SYSTEM SHALL

BE FREE OF TROUBLE AND FAULTS AT COMPLETION OF

INSTALLATION ACTIVITIES.

PROVIDE A NEW EXHAUST PIPE, MUFFLER, SUPPORT HANGERS,

FLEXIBLE CONNECTION, RAIN CAP AND SLEEVE TO PENETRATE

WALL. EXHAUST PIPE SHALL BE WRAPPED WITH MINERAL WOOL

WHEN PENETRATING EXTERIOR SLEEVE AND EXTERIOR SHALL

BE SEALED WITH HIGH HEAT CAULK. ROUTE NEW EXHAUST PIPE

THROUGH EXISTING WALL PENETRATION AND BRACE NEW

MUFFLER TO EXTERIOR OF BUILDING. EXHAUST SYSTEM SHALL

BE INSTALL AS PER MANUFACTURER'S RECOMMENDATION.

PATCH EXISTING OPENING FROM DEMOLISHED EXHAUST PIPE.

PATCH TO MATCH EXISTING SYSTEM.

FIRE PUMP SCHEDULE

ITEM NO.

CAPACITY(GPM) PRESSURE(PSI)

RPM MAX BHP

1032-PFW-1 2500 125 1760 202

1032-PFW-2 2500 125 1785 174

1032-PFW-3 2500 125 1760 202

1032-PFW-4 2500 125 1760 202

ENGINE SCHEDULE

ITEM NO. MOTOR TYPE BHP

1032-PFW-1 DIESEL

310@2100 RPM

1032-PFW-2 DIESEL

310@2100 RPM

1032-PFW-3 DIESEL

310@2100 RPM

1032-PFW-4 DIESEL

310@2100 RPM

3 3 3

1 21

FIRE PUMP CONTROLLER FPC

FIRE PROTECTION LEGEND:

EX EXISTING TO REMAIN

MONACO TRANSCEIVERXCVR

FIRE ALARM CONTROL UNITFACU

NOTE: EXISTING ENGINE RATINGS ARE FOR INFORMATION ONLY.

CONTRACTOR TO VERIFY.

NOTE: EXISTING FIRE PUMP RATINGS ARE FOR INFORMATION ONLY. CONTRACTOR TO VERIFY.

File details come from the government source that posted it. Updated .