FILE 15 OF 15 09 Telecomm Design Complete REV 01-12-2021.pdf
PDF 4 MB Posted
- Solicitation number
- W9128A21R0004
About this file
This federal contract opportunity announcement is for project number 76897 to construct an aircraft maintenance hangar at Wheeler Army Airfield in Oahu, Hawaii. The project includes building an aircraft hangar, associated maintenance shops, administrative space, parts and tool storage, hazardous materials storage, POL storage, GSE storage, hangar access apron, aircraft washing apron and pavement. Additional facilities include site development, utilities, fire suppression, lighting, paving, parking, drainage, landscaping and signage. Sustainability and cybersecurity measures will be incorporated. The contract type will be fixed price and the project value is between $50-100 million. The solicitation is a best value tradeoff RFP and proposals will be evaluated on experience, past performance, organization, small business participation plan, and price. The NAICS code is 236220 and proposals are due on SAM.gov. The small business size standard is $39.5 million average annual revenue.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-001
TE
LE
C O
M M
U N
IC
AT
IO
N
S
SY
M
BO
LS
, L
EG
EN
D A
N D
AB
BR
EV
IA
TI
O
N S
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
ABBREVIATIONS TELECOMMUNICATIONS SYMBOLS AND LEGEND
A AMPERE
ACN AIRCRAFT NOTEBOOK
AF AMPERE FRAME
AFF ABOVE FIXED FLOOR
AGL ABOVE GROUND LEVEL
AHU AIR HANDLING UNIT
AIC AMPERE INTERRUPTING CAPACITY
ANT ANTENNA
AP AIMING POINT
AT AMPERE TRIP
AUTO AUTOMATIC
AWG AMERICAN WIRE GAUGE
BATT BATTERY
BC BARE COPPER
BL BLACK
BLK(S) BLOCK(S)
C CONDUIT
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CB CIRCUIT BREAKER
CKT CIRCUIT
CLG CEILING
CONC CONCRETE
COND CONDUCTOR
CONN CONNECTION
CONT CONTROL
CORR CORRIDOR
CP CONSOLIDATION POINT
CT CURRENT TRANSFORMER
CU COPPER
DB DIRECT BURIAL
dB DECIBEL
DC DIRECT CURRENT
DEG DEGREE
DET(S) DETAIL(S)
DF DEMAND FACTOR
DIA DIAMETER
DIAG DIAGRAM
DISC DISCONNECT
DOIM DIRECTORATE OF INFORMATION
MANAGEMENT
DPW DIRECTORATE OF PUBLIC WORKS
DWG(S) DRAWING(S)
EA EACH
ELEC ELECTRICAL
EMER EMERGENCY
ENCL ENCLOSURE
EP EXPLOSION PROOF
EQL EQUAL
EQUIP EQUIP
EXH EXHAUST
EXST EXISTING
EXT EXTERIOR
FA FIRE ALARM
FCP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FG FINISH GRADE
FL FLOOR
FM FLOOR MOUNT OR FACTORY MUTUAL
FLUOR FLUORESCENT
FT FOOT (FEET)
FU FUSE
FXTR FIXTURE
G GROUNDING CONDUCTOR OR GREEN
GALV GALVANIZE
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPT
GF/CI GOVERNMENT FURNISHED/ CONTRACTOR
INSTALLED
GF/GI GOVERNMENT FURNISHED/ GOVERNMENT
INSTALLED
GL GROUND LEVEL
GND GROUND OR GROUNDING
HDBC HARD DRAWN BARE COPPER
HH HANDHOLE
HP HORSEPOWER
HPS HIGH PRESSURE SODIUM
HR HOUR
HV HIGH VOLTAGE
HZ HERTZ
IDS INTRUSION DETECTION SYSTEM
IN INCH
INCAND INCANDESCENT
INCL INCLUDE
INSTL INSTALLATION
INTERCOM INTERCOMMUNICATIONS
INTR INTERIOR
JB JUNCTION BOX
JC JANITOR CLOSET
J-SIIDS JOINT-SERVICE INTERIOR INTRUSION
DETECTION SYSTEM
K KILO
KV KILOVOLT
KCMIL THOUSAND CIRCULAR MILS
KVA KILOVOLT-AMPERE
KW KILOWATT
L LONG
LA LIGHTNING ARRESTER
LAN LOCAL AREA NETWORK
LG LENGTH
LPS LOW PRESSURE SODIUM
LTG LIGHTING
LV LOW VOLTAGE
MAG MAGNETIC
MAN MANUAL
MAX MAXIMUM
MECH MECHANICAL
MED MEDIUM
MH MOUNTING HEIGHTS
MIN MINIMUM
MS MOTOR STARTER
MTD MOUNTED
MTG MOUNTING
MTR METER
MWR OFFICE OF MORALE, WELFARE, AND
RECREATION
NIC NOT IN CONTRACT
NIPR NONSECURED INTERNET PROTOCOL
ROUTER NETWORK
NO NUMBER
NEMA NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
OC OVERCURRENT
O/H OVERHEAD
OL OVERLOAD
ONU OPTICAL NODE UNIT
P POLE
PA PUBLIC ADDRESS
PAR PASSIVE PRESSURE
PF POWER FACTOR
PH PHASE
PNLBD PANELBOARD
PRI PRIMARY
PROT PROTECTION
PVC POLYVINYL CHLORIDE CONDUIT
PWR POWER
QTY QUANTITY
RCPT RECEPTACLE
REPL REPLACE
REQ'D REQUIRED
RGS RIGID ZINC-COATED STEEL CONDUIT
RM ROOM
RPM REVOLUTIONS PER MINUTE
RR REMOVE & REINSTALL
RTU REMOTE TERMINAL UNIT
SAF SAFETY
SCHED SCHEDULE
SEC SECONDARY
SECT SECTION
SEL SELECTOR
SERV SERVICE
SH SHEET
SIG SIGNAL
SM
SN SOLID NEUTRAL
SPEC SPECIFICATION
SQ SQUARE
SS STAINLESS STEEL
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
SURF SURFACE
SW SWITCH
SYS SYSTEM
TEL TELEPHONE
TEMP TEMPERATURE
TERM TERMINAL
TGB TELECOMMUNICATIONS GROUND BUS BAR
THK THICK
TMGB TELECOMMUNICATIONS MAIN GROUND BUS BAR
TMH TELECOMMUNICATIONS MAINTENANCE HOLE
TMR TIMER
TR TELECOMMUNICATIONS ROOM
TTC TELEPHONE TERMINAL CABINET
TYP TYPICAL
TV TELEVISION
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTED POWER SUPPLY
V VOLT
VA VOLT-AMPERE
W WIDTH OR WHITE
W/ WITH
W/O WITHOUT
WHM KILOWATT-HOUR METER
WP WEATHERPROOF
XFR TRANSFER
XFMR TRANSFORMER
& AND
# NUMBER
PHASE
FO, FOC FIBER OPTIC CABLE (SINGLE MODE)
ONE VOICE, ONE DATA WALL MOUNT TELECOMMUNICATIONS OUTLET UNLESS
OTHERWISE INDICATED BY NUMBER
ONE VOICE, ONE DATA FLOOR MOUNT TELECOMMUNICATIONS OUTLET UNLESS
OTHERWISE INDICATED BY NUMBER
SINGLE DATA OUTLET, UNLESS INDICATED BY NUMBER
SINGLE VOICE OUTLET, UNLESS INDICATED BY NUMBER
CATV OUTLET, TYPE "F" CONNECTOR
TELECOMMUNICATIONS MAIN GROUND BUS BAR (TMGB)
TELECOMMUNICATIONS GROUND BUS BAR (TGB)
CONDUIT (HORIZONTAL)
CONDUIT (VERTICAL)
CABLE TRAY, BASKET TYPE, MOUNTED IN RECESSED CEIILING SPACE 9'-0" AFF NOM
3/4" PLYWOOD BACKBOARD, FIRE RATED
CABLE LADDER, WALL MOUNTED
DESCRIPTIONSYMBOL
TV
TMGB
TGB
J JUNCTION BOX, SIZE AS NOTED, CEILING MOUNTED, NEMA 1 UON
CABLE TRAY, LADDER TYPE MOUNTED 8'-0" AFF NOM
THH TELECOMMUNICATION HAND HOLE
SINGLE MODE FIBER OPTIC CABLE
TELECOM CONDUIT WITH PULLCORD, STUB TO
CABLE TRAY, SEE DETAIL A5, SHEET T-514
1" TELECOM CONDUIT WITH CAT-6 CABLES. NUMBER
INDICATES CABLE QUANTITY. ENSURE TELECOM CONDUITS
CONCEALED WHERE POSSIBLE
1" TELECOM CONDUIT WITH CAT-6 CABLES. HOMERUN TO
TELECOM CABINET ROOM 102. NUMBER INDICATES CABLE QUANTITY.
ENSURE TELECOM CONDUITS CONCEALED WHERE POSSIBLE
1" TELECOM CONDUIT WITH CAT-6 CABLES. STUB CONDUIT TO CABLE TRAY WITH
CONDUIT CLAMP. HOMERUN CABLE TO TELECOM ROOM. ENSURE TELECOM
CONDUITS CONCEALED WHERE POSSIBLE.
1" CATV CONDUIT WITH RG-6 CABLES. HOMERUN CABLE TO TELECOM
ROOM. ENSURE CATV CONDUITS CONCEALED WHERE POSSIBLE
T2
T2
DENOTES OUTLET IS TO BE LOCATED ABOVE COUNTERTOPAC
1 1/4" TELECOM CONDUIT WITH CAT-6 CABLES. STUB CONDUIT TO CABLE TRAY
WITH CONDUIT CLAMP. HOMERUN CABLE TO TELECOM ROOM. ENSURE TELECOM
CONDUITS CONCEALED WHERE POSSIBLE.
DENOTES UL LISTED FOR WET LOCATION AND WHILE IN-USE COVERWP
DENOTES MOUNTING HEIGHT ABOVE FINISHED FLOOR MEASURED TO
BOTTOM (INCHES)
+12
TELECOM CONDUIT SLEEVE. FIRE STOP AS REQUIRED
ACS ACCESS CONTROL SYSTEM
DDC DIRECT DIGITAL CONTROL
WAP WIRELESS ACCESS POINT
DENOTES OUTLET TO BE USED BY DDC PANEL. COORDINATE OUTLET
LOCATION WITH INSTALLATION OF DDC PANEL
DENOTES OUTLET INCLUDES ONE 8-POSITION RJ-45 TYPE CAT-6 (WHITE IN
COLOR FOR ACN) UNLESS INDICATED BY NUMBER, SEE T-501. HOMERUN
CABLE(S) TO ROOM 138 OR FOR OUTLETS LOCATED IN RM 102, ACN CABINET
GATE KEYPAD, MOUNT AT +42"
INTERCOM SUB-STATION, MOUNT AT +42"
DDC
U
K
IMS
DENOTES OUTLET INCLUDES ONE DATA 8-POSITION RJ-45 TYPE CAT-6 (GREEN
IN COLOR FOR ACN) UNLESS INDICATED BY NUMBER, SEE T-501D
DENOTES OUTLET INCLUDES ONE VOICE 8-POSITION RJ-45 TYPE CAT-6 (BLUE
IN COLOR FOR ACN) UNLESS INDICATED BY NUMBER, SEE T-501V
J JUNCTION BOX, SIZE AS NOTED, WALL MOUNTED, NEMA 1 UON
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND
TRANSPORTATION OFFICIALS
AC ASPHALT CONCRETE
AMP AMPERAGE
ACI AMERICAN CONCRETE INSTITUTE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
BR BROWN
BRKR BREAKER
BTU BRITISH THERMAL UNIT
BLDG BUILDING
CALC CALCULATION
CAB CABINET
COR CONTRACTING OFFICER REPRESENTITIVE
D DEPTH
DIST DISTRIBUTION
(E) EXISTING
EF ENTRANCE FACILITY
E.G. EXEMPI GRATIA
ETC ET CETERA "AND OTHER THINGS"
HD HEAVY DUTY
IBF POUND (FORCE)
IAW IN ACCORDANCE WITH
I3A INSTALLATION INFORMATION INFRASTRUCTURE ARCHITECTURE
LRFD LOAD AND RESISTANCE FACTOR DESIGN
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NET NETWORK
NEC NATIONAL ELECTRIC CODE 2020
NOM NOMINAL
O ORANGE
OSP OUTSIDE PLANT
PCF PARALLEL
PNL PANEL
PSI POUNDS PER SQUARE INCH
SPC STORED PROGRAM CONTROL
SVC SERVICE
TIA TELECOMMUNICATIONS INDUSTRY ASSOCIATION
UL UNDERWRITER LABORATORIES
UG UNDERGROUND
UFC UNITED FACILITIES CRITERIA
ONE DATA FLOOR MOUNT TELECOMMUNICATIONS OUTLET UNLESS OTHERWISE
INDICATED BY NUMBER
J
J
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-002
G
EN
ER
AL
T
EL
EC
O
M M
U N
IC
AT
IO
N
N O
TE
S
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
GENERALTELECOMMUNICATIONS NOTES
1. THE CONTRACTOR SHALL COMPLY WITH THE LATEST VERSION OF ALL
APPLICABLE CRITERIA INCLUDING, BUT NOT LIMITED TO NFPA 70, ANSI, TIA,
UFC, ETC.
2. ALL DEVICES AND EQUIPMENT SHALL BE UL LISTED OR FM APPROVED.
3. SHOP DRAWING OR ANY ACTION FOR TELECOMMUNICATIONS WORK WILL BE
SUBMITTED TO THE CONTRACTING OFFICER FOR CONCURRENCE PRIOR TO
ANY WORK TAKING PLACE.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORING ALL DAMAGED
AREA INCLUDING SODDING, UTILITIES, STRUCTURES, ETC TO THEIR ORIGINAL
CONDITION AND OPERATION DURING AND AFTER INSTALLATION OF
TELECOMMUNICATIONS SYSTEM. THE GRADING LINE OF NEW DUCTS WILL BE
LIMITED TO THE WIDTH OF DUCT EXCAVATION.
5. WHEN UNKNOWN EXISTING UNDERGROUND TELECOMMUNICATIONS CABLES
ARE FOUND IN THE PROJECT SITE DURING CONSTRUCTION BY THE
CONTRACTOR, ANY REMOVAL OR RELOCATION WORK SHALL BE
COORDINATED WITH THE CONTRACTING OFFICE AND THE NEC.
6. WHEN UNKNOWN EXISTING UNDERGROUND POWER CABLES ARE FOUND IN
THE PROJECT SITE DURING CONSTRUCTION BY THE CONTRACTOR, ANY
REMOVAL OR RELOCATION WORK SHALL BE COORDINATED WITH THE DPW
AND ELECTRICAL UTILITY SHOP.
7. FOR ANY REMOVAL WORK THAT WILL REQUIRE DIGGING, THE CONTRACTOR
MUST HAVE DIGGING PERMITS SUBMITTED TO THE NEC TO IDENTIFY ANY
COMMUNICATIONS CABLES THAT MAY BE AFFECTED BY THIS PROJECT.
CONTRACTOR TO COORDINATE WITH DPW AND FIELD OFFICE TO DETERMINE
IF THERE ARE ANY OTHER UTILITIES WITHIN THE PROJECT SITE.
8. LABELING / IDENTIFICATION NUMBER OF EACH COMMUNICATIONS DROPS AND
CABINET RACKS SHALL BE PERFORMED BY THE CONTRACTOR IN
ACCORDANCE WITH 30TH SIGNAL LABELING STANDARD, DATED JAN 2011.
9. THE CONTRACTOR SHALL TERMINATE ALL TELECOMMUNICATIONS CABLE
BETWEEN THE COMMUNICATIONS ROOM AND EVERY JACK. CABLES IN TRAY
SHALL BE BUNDLED BY SYSTEM / TYPE (VOICE, DATA, ACN, ETC).
CONTRACTOR SHALL NOTIFY THE GOVERNMENT PRIOR TO COMPLETION OF
FINAL CABLE TERMINATIONS.
10. ALL ELECTRICAL JUNCTION BOXES, PULL BOXES, WIRING TRAYS, ETC SHALL
BE ACCESSIBLE TO AUTHORIZED PERSONNEL DURING FINAL INSPECTION IN
FINISHED STATE PER NEC 300.23 AND 314.29.
11. PROVIDE GROUNDING IN ACCORDANCE WITH MIL-STD-188-124B. DO NOT
BOND TMGB/TGB TO FAULT PROTECTION GROUND SYSTEM. PROVIDE
GROUNDING ELECTRODE CONDUCTOR, MINIMUM #1/0 AWG IN SIZE AND
TERMINATE AT THE FACILITY EARTH ELECTRODE SYSTEM. BOND THE SIGNAL
GROUND BAR TO THE GROUND CABLE, WITH BONDING CONDUCTOR, MINIMUM
#1/0 AWG.
12. TELECOMMUNICATIONS AND OTHER CIRCUITS SHALL NOT PENETRATE ANY
EXIT PASSAGEWAY UNLESS THIS CIRCUIT SERVICES AN APPLIANCE REQUIRED
FOR AND INSTALLED WITHIN THE EXIT PASSAGEWAY.
13. ALL UNDERGROUND CONDUITS SHALL BE CONCRETE ENCASED SCHEDULE 40
PVC CONDUITS EXCEPT ANY CONDUIT PENETRATING AND PASSING THROUGH
BLDG CONCRETE SLAB SHALL BE RIGID STEEL CONDUIT. USE OF RIGID STEEL
CONDUIT SHALL BE ALSO USED WITHIN 6" PRIOR TO PENETRATING CONCRETE
SLAB.
14. CONDUITS SHALL EXTEND BETWEEN 4" TO 6" AFF TO AID IN PULLING CABLES
AND SHALL BE PLACED WITHIN 3" OF THE WALL. IN ADDTION, WHERE
CONDUITS ENTERS A BUILDING AND SWEEPS UP THROUGH A FLOOR SLAB,
GALVANIZED RGS SHALL BE USED.
15. CONDUITS ARE ALLOWED TO BE EMBEDDED IN CONCRETE FLOOR SLAB.
CONDUITS IN CONCRETE SLABS SHALL NOT OVERLAP AND CABLES INSTALLED
SHALL BE RATED FOR WET LOCATIONS. THE CONTRACTOR SHALL FOLLOW ACI
318-83 CHAPTER 6.3 FOR MINIMUM SLAB THICKNESS AND MAXIMUM CONDUIT
SIZE. WHERE CONDUIT IS EMBEDDED IN SLAB OUTDOOR RATED CAT-6 CABLE
SHALL BE PROVIDED.
16. 12" CLEARANCE SHALL BE PROVIDED FOR TELECOMMUNICATIONS CABLE
TRAYS.
17. ANY CIRCUIT OF VOICE/DATA/ACN SYSTEM SHALL BE 4 PAIR, UNSHIELDED
TWISTED PAIR (UTP), CATEGORY 6 CABLE.
18. ANY OUTLET BOXES FOR RECEPTACLES, TELECOMMUNICATIONS, CATV, ETC
SHALL NOT BE INSTALLED BACK TO BACK ON A COMMON WALL.
19. MOUNTING HEIGHTS ABOVE FINISHED FLOOR SHALL BE AS FOLLOWS UNLESS
OTHERWISE NOTED.
TELECOMMUNICATIONS OUTLET ........................18" TO CENTER OF OUTLET UON.
TELECOMMUNICATION OUTLET IN HAZARDOUS LOCATION (SEE E-101)
34" MINIMUM TO BOTTOM OF OUTLET UON.
CATV OUTLET...........................18" TO CENTER UON.
PHONE OUTLET (AS NOTED ON PLANS).......................48" TO CENTER UON.
WAP OUTLET (AS NOTED ON PLANS).......................10'-0" TO CENTER UON.
20. PROVIDE SEISMIC BRACING FOR TELECOMMUNICATIONS SYSTEM (EQUIPMENT
RACKS, CABLE TRAYS/LADDERS, CABINETS, ETC.).
21. FOR ISOLATION JOINT LOCATIONS BETWEEN HANGAR MAINTENANCE BAY AND
HANGAR ADMINISTRATION WING CMU WALLS, SEE SHEETS S-203 THROUGH
S-206 OF STRUCTURAL DRAWINGS.
FACILITY STORAGE ROOM
CREW CHIEF WORK ROOM
(COMPANY C)
AVIATION LIFE SUPPORT
EQUIPMENT (ALSE) SHOP
CREW CHIEF WORK ROOM
(COMPANY B)
AVIATION LIFE SUPPORT
EQUIPMENT (ALSE)
STORAGE
UNIT STORAGE (COMPANY
D)
CREW CHIEF WORK ROOM
(COMPANY A)
ARMS VAULT (COMPANY D)
RECYCLE ROOM
ELECTRICAL ROOM
COMMUNICATIONS ROOM
AIRLOCK 1
157E
MEN'S
QUALITY CONTROL
WOMEN'S
PRODUCTION CONTROL
JANITOR
ACN EQUIPMENT
QUALITY CONTROL OFFICE
PRODUCTION CONTROL
OFFICE
ELECTRICAL ROOM
COMMUNICATIONS ROOM
SPECIAL TOOLS ROOM
CORRIDOR 4
157D
MOTHER'S ROOM
CORRIDOR 2
157B
1D 1V 1U
1D 1U
1D 1U
DDC
T-401 A1
T-401 D1
T-401 A5
TV
TVTV
1D 1V 1U
1D 1V 1U
1D 1V 1U
2D 2V
2D 2V
2D 2V
2D 2V
1D 1V 1U
AC
1D 1V 1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
2D 2V
1D 1V 1U AC
1D 1V 1U
AC
2D 1V 1U
3D 1V
3D 1V
2D
1 3 4 5 6
A
C
E
1.9 2.9 3.9 4.4 5.6 6.60.9
SEE T-105
MATCHLINE
MULTI PURPOSE / BREAK /
CONF
M
AT
C H
LI
N
E
SE
E T-
SEE T-104
MATCHLINE
SEE T-105
MATCHLINE
M
AT
C H
LI
N
E
SE
E T-
SEE T-104
MATCHLINE
1D 1U
AC
1D 1U 1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
1D 1U AC
1D 1U AC
1D 1U AC 1D
1U
AC
1D 1U
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
1D 1U AC
1D 1U AC
1D 1U AC 1D
1U
AC
1D 1U
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
1D 1U AC
1D 1U AC
1D 1U AC
1D 1U 1D 1U
1D 1U 1D 1U
TV TV
TV
21D 1U 1D 1U 1D 1U
1D 1U
1D 1V 1U
TV
TV
TV
2D 2V
1D 1U
1D 1U
1D 1U
J
J
J
1D 1V 1U
TV
TV 3
J
TV
TV 3
TV 3
TV 3
2D
C152 C149 C147
C131
A
CD
B E
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-101
TE
LE
C O
M P
LA
N
SE
C
TI
O N
A
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/8" = 1'-0"A1 TELECOM PLAN - SECTION A
PLAN NORTH
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
1 BUILT-IN COUNTERTOP (30"(H) X 24"(W)). SEE DETAIL A8, SHEET A-751. MOUNT OUTLET 4" ABOVE COUNTER.
24"(W)x4"(H) BASKET TYPE CABLE TRAY. MTD IN RECESSED CEILING SPACE APPROXIMATELY 9'-0" AFF.
MOUNT +72" AFF.
ROOM CLASSIFIED AS HAZARDOUS LOCATION; MOUNT MINIMUM 34" ABOVE FINISHED FLOOR TO BOTTOM
OF OUTLET.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL A1, SHEET EP505. SEE I-101 FURNITURE PLAN
AND COORDINATE OUTLET LOCATION WITH ACTUAL FURNITURE TO BE INSTALLED.
SEE KEYNOTES 35 AND 36 SHEET T-602 FOR REQUIREMENTS.
1'-4"C FROM RM 138. WIRING BY OTHERS. SEE T-605.
1'-4"C FROM JUNCTION BOX TO ROOF/ANTENNA PLATFORM (SEE A-155). PROVIDE JUNCTION BOXES AS
REQUIRED. SEE T-002 FOR REQUIREMENTS.
FOR IDS, SEE DETAIL A6 SHEET EY501 FOR CABLE REQUIREMENTS. PROVIDE NEMA 1, 6"(W)x6"(L)x4"(D)
JUNCTION BOX MOUNTED 18" AFF.
PHONE OUTLET MOUNTED 48" AFF.
KEY NOTES:
GENERAL NOTES:
1. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF
CONDUIT AND NOT USED IN LIEU OF A BEND.
2. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A
CONTINUOUS CONDUIT EXTENDS OVER 100' OR WHERE THERE ARE MORE
THAN TWO 90 DEGREE BENDS.
3. WALL MOUNTED TELECOM OUTLETS LOCATED AT WORK STATIONS IN NON
HAZARDOUS LOCATIONS ARE TO BE COORDINATED WITH ACTUAL
FURNITURE TO BE INSTALLED. ENSURE MOUNTING HEIGHT WILL NOT IMPEDE
INSTALLATION OF FURNITURE. SEE I-101 FURNITURE PLAN.
4. REFER TO SHEET F-102 FOR FIRE RATED WALL LOCATIONS.
1 11
4 4
1 1
1 1 1
4 4 4
REPAIR SECTION
WORKROOM
FIRE PROTECTION
MECHANICAL ROOM
AIRFRAME REPAIR PLATOON
OFFICE
AIRFRAME REPAIR PLATOON
COMPONENT REPAIR
PLATOON OFFICE
COMPONENT REPAIR
PLATOON
AIRCRAFT MOUNTED
WEAPONS VAULT
COMSEC SECURE STORAGE
SYSTEMS REPAIR SHOP
CONTRACTOR LOGISTICS
SUPPORT
LOGISTICS ASSISTANCE
REPRESENTATIVES (LARS)
COMMUNICATIONS ROOM
ELECTRICAL ROOM
1ST SERGEANT OFFICE
COMMANDER OFFICE
NONDESTRUCTIVE
INSPECTION (NDI) ROOM
POWER PLANT/
POWERTRAIN SHOP
ORDERLY ROOM (COMPANY
D)
SHOP SECTION HQ
PLATOON OFFICE
STRUCTURAL REPAIR SHOP
MECHANICAL ROOM
COMPRESSOR ROOM
BLADE REPAIR SHOP
CORRIDOR 1
157A
CORRIDOR 2
157B
AIRLOCK 3
157G
2D
2U1D 1U AC
1D 1U AC
1D 1U AC
1D 1U AC
1D 1U
1D 1U 1D 1U
2D
2D 2U
1D 1U
2U
2D 2U
2D 2U
1D 1V 1U
1D 1U 1D 1U
D D
C2D 1V
D D
C D
D C
A
C
E
8 9 10 11 12 13
C.9
7.5 8.4 9.4 10.4 12.1 13.1
1D
IV
1U
1D
IV
1U
1D
IV
1U
1D
IV
1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
1D 1V 1U
SE
E
T-
M
AT
C
H
LI
N E
SEE T-105
MATCHLINE
SE
E
T-
SE
E T-
1D 1U AC
1D 1U AC
1D 1U AC
1D 1U AC 1D
1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U
AC
1D 1U AC
2D 2U
2D 2U
2D 2U
2D 2U
2D 2U
2U 2U
2U 2U
TV
TV
TVTV
TV
1D 1U 1D
1U
2U
1D 1U
J J
C108B
A
CD
B E
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-102
TE
LE
C O
M P
LA
N
SE
C
TI
O N
B
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/8" = 1'-0"A1 TELECOM PLAN - SECTION B
PLAN NORTH
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
KEY NOTES:
BUILT-IN COUNTERTOP (30"(H) X 24"(W)). SEE DETAIL A8, SHEET A-751. MOUNT OUTLET 4" ABOVE COUNTER.
24"(W)x4"(H) BASKET TYPE CABLE TRAY. MTD IN RECESSED CEILING SPACE APPROXIMATELY 9'-0" AFF.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL A4, SHEET EP505. SEE I-101 FURNITURE PLAN
AND COORDINATE OUTLET HEIGHT WITH ACTUAL FURNITURE TO BE INSTALLED.
ROOM CLASSIFIED AS HAZARDOUS LOCATION; MOUNT MINIMUM 34" ABOVE FINISHED FLOOR TO BOTTOM
OF OUTLET.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL A1, SHEET EP505. SEE I-101 FURNITURE PLAN
AND COORDINATE OUTLET LOCATION WITH ACTUAL FURNITURE TO BE INSTALLED.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL A8, SHEET EP505. SEE I-101 FURNITURE PLAN
AND COORDINATE OUTLET LOCATION WITH ACTUAL FURNITURE TO BE INSTALLED.
OUTLET FOR FIRE ALARM CONTROL PANEL(S); COORDINATE LOCATION WITH INSTALLATION. SEE FA104.
FOR IDS, SEE DEAIL A6 SHEET EY501 FOR CABLE REQUIREMENTS. PROVIDE NEMA 1, 6"(W)x6"(L)x4"(D)
JUNCTION BOX MOUNTED 18" AFF.
PHONE OUTLET MOUNTED 48" AFF.
GENERAL NOTES:
1. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF
CONDUIT AND NOT USED IN LIEU OF A BEND.
2. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A
CONTINUOUS CONDUIT EXTENDS OVER 100' OR WHERE THERE ARE MORE
THAN TWO 90 DEGREE BENDS.
3. WALL MOUNTED TELECOM OUTLETS LOCATED AT WORK STATIONS IN NON
HAZARDOUS LOCATIONS ARE TO BE COORDINATED WITH ACTUAL
FURNITURE TO BE INSTALLED. ENSURE MOUNTING HEIGHT WILL NOT IMPEDE
INSTALLATION OF FURNITURE. SEE I-101 FURNITURE PLAN.
4. REFER TO SHEET F-102 FOR FIRE RATED WALL LOCATIONS.
9 9
8 8
AIRCRAFT PARTS SUPPLY
OFFICE / 101
AIRCRAFT PARTS SUPPLY /
CORRIDOR 3
157C
PNEUDRALICS REPAIR SHOP
1D 1U 1D 1U
1D 1U 1D 1U 1V
1D 1U
E
F
G
H
13 14
C.9
13.1
H.1
TGB
ACN TELECOM CABINET
DATA/VOICE TELECOM CABINET
3/4" FIRE RATED PLYWOOD BACKBOARD
SE
E
T-
M
AT
C
H
LI
N E
1D 1U 1D 1U
1D 1U
CABLE LADDER
1D 1U 1D 1U
1D 1U
C101
A
CD
B E
KEY PLAN
F2F1
FB
FA
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-103
TE
LE
C O
M P
LA
N
SE
C
TI
O N
C
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/8" = 1'-0"A1 TELECOM PLAN - SECTION C
PLAN NORTH
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
KEY NOTES:
SEE T-503 FOR DETAILS.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL
A1, SHEET EP505. SEE I-101 FURNITURE PLAN AND
COORDINATE OUTLET HEIGHT WITH ACTUAL FURNITURE TO
BE INSTALLED.
ROOM CLASSIFIED AS HAZARDOUS LOCATION; MOUNT
MINIMUM 34" ABOVE FINISHED FLOOR TO BOTTOM OF
OUTLET.
OUTLET TO BE INSTALLED ABOVE WORKBENCH; SEE DETAIL
A8, SHEET EP505. SEE I-101 FURNITURE PLAN AND
COORDINATE OUTLET LOCATION WITH ACTUAL FURNITURE
TO BE INSTALLED.
GENERAL NOTES:
1. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF
CONDUIT AND NOT USED IN LIEU OF A BEND.
2. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A
CONTINUOUS CONDUIT EXTENDS OVER 100' OR WHERE THERE ARE MORE
THAN TWO 90 DEGREE BENDS.
3. WALL MOUNTED TELECOM OUTLETS LOCATED AT WORK STATIONS IN NON-
HAZARDOUS LOCATIONS ARE TO BE COORDINATED WITH ACTUAL
FURNITURE TO BE INSTALLED. ENSURE MOUNTING HEIGHT WILL NOT IMPEDE
INSTALLATION OF FURNITURE. SEE I-101 FURNITURE PLAN.
4. TELECOM OUTLETS LOCATED ROOMS 102, 103 AND NORTH CORNER OF
MAINTENANCE BAY100 WILL LIKLY EXCEED 295' IF FED FROM NEAREST
TELECOM ROOM. CONNECT OUTLETS TO TELECOM CABINET IN ROOM 102.
5. REFER TO F-102 FOR FIRE RATED WALL LOCATIONS.
T2
T2
T2
T1
T2 T2
T1
T2
T2
T2
T2
T2 4
2 2
J.
FOR TELCOM OUTLET IN FIRE PUMP BUILDING,
HOMERUN (1) 1" EMT CONDUIT WITH (1) CAT-6
CABLE TO DATA/VOICE TELECOM CABINET
(RM102). SEE TS101
1/8" = 1'-0"A6 TELECOM PLAN - FIRE PUMP BUILDING
T1.
FOR DDC. HOMERUN CABLE TO
TELCOM CABINET IN RM102. SEE TS101
WP
W P
2U
WP
AIRCRAFT MAINTENANCE
BAY
1 2 3 4 5 6
E
F
G
H
J
K
1.9 2.9 3.9 4.4 5.6 6.60.9
M
AT
C H
LI
N
E
SE
E T-
MATCHLINE
SEE T-101
2U
WP
AIRCRAFT UTILITY
STAND, TYP
1U
WP
FOR WAP, MTD 10'-0" AFF
1U
WP
FOR WAP, MTD 10'-0" AFF
2D
WP
2D
WP
FOR WAP, MTD 10'-0" AFF
WPWP
A
CD
B E
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-104
TE
LE
C O
M P
LA
N
SE
C
TI
O N
D
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/8" = 1'-0"A1 TELECOM PLAN - SECTION D
PLAN NORTH
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
KEYNOTES:
SEE DETAIL B6 ON SHEET EP503 FOR MOUNTING TELECOM/DATA
OUTLETS ON AIRCRAFT UTILITY STANDS. SEE SHEET EP503/A1
FOR UTILITY STAND TRENCH DETAIL. CONDUIT SHALL BE 1"C
RIGID STEEL TYPE AND INSTALLED IN ACCORDANCE WITH 26 20
00 SECTION 3.1.2 HAZARDOUS AREAS. CABLES INSTALLED
WITHIN OR UNDER SLAB SHALL BE UL LISTED AND LABELLED FOR
WET LOCATIONS. SEE 27 10 00 FOR CABLE REQUIREMENTS.
SEE DETAIL C5, SHEET T-503.
ROOM CLASSIFIED AS HAZARDOUS LOCATION; MOUNT MINIMUM
34" ABOVE FINISHED FLOOR TO BOTTOM OF OUTLET.
GENERAL NOTES:
1. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF
CONDUIT AND NOT USED IN LEIU OF A BEND.
2. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A
CONTINUOUS CONDUIT EXTENDS OVER 100' OR WHERE THERE ARE MORE
THAN TWO 90 DEGREE BENDS.
3. REFER TO SHEET F-102 FOR FIRE RATED WALL LOCATIONS.
2 2
1 1
WP
W P
WPWP
2U
WP
2U
WP
AIRCRAFT MAINTENANCE
BAY
E
F
G
H
J
K
7 8 9 10 11 12 13
7.5 8.4 9.4 10.4 12.1 13.1
H.1 M
AT
C H
LI
N
E
SE
E T-
SE
E
T-
SE
E T-
SE
E
T-
SE
E T-
SE
E
T-
M
AT
C
H
LI
N E
AIRCRAFT UTILITY
STAND, TYP
2U
WP
1U
WP
FOR WAP, MTD 10'-0" AFF 1U
WP
FOR WAP, MTD 10'-0" AFF
2D
WP
2D
WP
2D
WP
1U
WP
FOR WAP, MTD 10'-0" AFF
A
CD
B E
KEY PLAN
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-105
TE
LE
C O
M P
LA
N
SE
C
TI
O N
E
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/8" = 1'-0"A1 TELECOM PLAN - SECTION E
PLAN NORTH
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
T1
T1
KEYNOTES:GENERAL NOTES:
1. TELECOM PULL BOXES SHALL BE PLACED ON STRAIGHT SECTIONS OF
CONDUIT AND NOT USED IN LIEU OF A BEND.
2. TELECOM PULLBOXES SHALL BE PLACED IN CONDUIT RUNS WHERE A
CONTINUOUS CONDUIT EXTENDS OVER 100' OR WHERE THERE ARE MORE
THAN TWO 90 DEGREE BENDS.
3. TELECOM OUTLETS LOCATED IN HANGAR BAY SHALL BE INSTALLED 48"
ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED.
4. REFER TO SHEET F-102 FOR FIRE RATED WALL LOCATIONS.
SEE DETAIL B6 ON SHEET EP503 FOR MOUNTING TELECOM/DATA
OUTLETS ON AIRCRAFT UTILITY STANDS. SEE SHEET EP503/A1
FOR UTILITY STAND TRENCH DETAIL. CONDUIT SHALL BE 1"C
RIGID STEEL TYPE AND INSTALLED IN ACCORDANCE WITH 26 20
00 SECTION 3.1.2 HAZARDOUS AREAS. CABLES INSTALLED
WITHIN OR UNDER SLAB SHALL BE UL LISTED AND LABELLED FOR
WET LOCATIONS. SEE 27 10 00 FOR CABLE REQUIREMENTS.
SEE DETAIL C5, SHEET T-503.
ROOM CLASSIFIED AS HAZARDOUS LOCATION; MOUNT MINIMUM
34" ABOVE FINISHED FLOOR TO BOTTOM OF OUTLET.
143.01
143.02
FR
O
N T
12" WX 4" H CABLE
TRAY, LADDER TYPE
3/4" FIRE RATED
PLYWOOD BACKBOARD,
8'-0" HIGH, TYP
FR
O
N T
110 BLOCKS
TGB
SPACE FOR CATV
EQUIPMENT AND DEVICES
CABLE TRAY
TELECOM
EQUIPMENT
RACK, TYP (2)
PLACES
PANEL CP1
ELECTRICAL
PANEL
4-4"C FOR TELECOM
BACKBONE AND 1-2"C FOR
CATV BACKBONE FROM TR
(RM 133)
1-2" FROM TR (RM 133) FOR GND
3-4"C STUBBED TO CABLE TRAY
FRONT FRONT FRONT
133.03 133.02 133.01
TM
G
B
PE
T
TELECOM MAIN
GROUND BUS BAR
110 BLOCKS
PROTECTIVE
ENTRANCE
TERMINAL
CABLE LADDER
(4) 4" DUCT U/G
STUB UPS FROM
TELECOM
MANHOLE
3/4" FIRE RATED PLYWOOD
BACKBOARD 8'-0" HIGH, TYP
TELECOM EQUIPMENT
RACK, TYP (3) PLACES
CABLE TRAY
PANEL CP3
1-2"C TO TR(143) FOR GND
1-2"C TO TR(118) FOR GND
1-2"C TO ACN RM(138) FOR GND
1-2"C TO RM(102) FOR GND
1-4" DUCT STUBUP
FOR CATV SVC
SPACE FOR CATV HEAD END
EQUIPMENT AND DEVICES
ELEC
PANEL
3-4"C STUBBED
TO CABLE TRAY
4-4"C FOR TELECOM BACKBONE AND 1-2"C
FOR CATV BACKBONE TO TR(RM 143)
4-4"C FOR TELECOM BACKBONE AND 1-2"C
FOR CATV BACKBONE TO TR(RM 118)
2-4"C FOR TELECOM
BACKBONE (RM 102) 4
138.01
138.02
FR
O
N T
FR
O
N T
12" WX 4" H CABLE
TRAY, LADDER TYPE
3/4" FIRE RATED
PLYWOOD BACKBOARD,
8'-0" HIGH, TYP
TG
B
TELECOM GROUND
BUS BAR
1D 1V 1U
TELECOM EQUIPMENT
RACK, TYP (2) PLACES
CABLE TRAY
1-4"C TO ACN CABINET STUB
CONDUIT TO CABLE TRAY
(RM 102)
1-4"C (WIRING BY OTHERS)
STUB CONDUIT TO CABLE
TRAY (RM 102)
3-4"C STUBBED TO
CABLE TRAY
1-2"C FROM TR(RM 133) FOR GND
1-4"C TO ROOF (WIRING BY OTHERS)
1-2"C TO BLDG ROOF FOR GND
PANEL CP4
ELECTRICAL
PANEL
FR
O
N T
118.01
FR
O
N T
118.02
CABLE TRAY FROM
CORRIDOR 157B
110 BLOCKS
SPACE FOR
CATV
EQUIPMENT
AND DEVICES
3/4" FIRE RATED
PLYWOOD
BACKBOARD
8'-0" HIGH, TYP
TELECOM EQUIPMENT
RACK, TYP (2) PLACES
4-4"C FOR TELECOM BACKBONE AND 1-2"C
FOR CATV BACKBONE TO TR(RM 133)
1-2"C FROM TR(133) FOR GND
TGB
PANEL CP2
ELECTRICAL
PANEL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-401
EN
LA
R G
ED
T
EL
EC
O M
M U
N
IC
AT
IO
N P
LA
N
S-
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
1/2" = 1'-0"A1 ENLARGED PLAN - TELECOMMUNICATIONS ROOM 143
1/2" = 1'-0"D1 ENLARGED PLAN - TELECOMMUNICATIONS ROOM 133
1/2" = 1'-0"A5 ENLARGED PLAN - ACN EQUIPMENT ROOM 138
1/2" = 1'-0"D5 ENLARGED PLAN - TELECOMMUNICATIONS ROOM 118
PLAN NORTH
2' 2' 4'
SCALE: 1/2"=1'-0"
1' 0'
KEYNOTES:
PHONE OUTLET MOUNTED AT 48". SEE DETAIL ON T-501.
SEE SHEET EP607 FOR PANEL SCHEDULE.
SEE SHEET T-601 FOR CABLING REQUIREMENTS.
SEE TELECOM RISER DIAGRAM (T-602, T-605) AND CATV RISER DIAGRAM (T-620) FOR
CABLING REQUIREMENTS.
ENTRANCE CONDUITS SHALL EXTEND 4'-6" AFF. ENSURE
CONDUITS ARE PLACED WITHIN 3" OF WALL.
PROVIDE NEW 3/4"C WITH (1) CAT-6 CABLE FROM ILON LOCATED IN ELEC ROOM 130
TO PATCH PANEL. TELECOMMUNICATION CONTRACTOR IS TO COORDINATE WITH
NEC TO HAVE A NEC TECH INSTALL THE CAT-6 FEEDER FROM ILON TO PATCH PANEL
AND MAKE THE FINAL CONNECTION INTO A NEW NEC-ASSIGNED NIPRNET SWITCH
PORT WITH NEW ADDRESS.
3-4"C STUBBED TO CABLE TRAY
GENERAL NOTES:
1. FIRE SPRINKLER PIPING SHALL NOT BE INSTALLED IN COMMUNICATION
ROOMS. PROVIDE SIDEWALL SPRINKLER(S) WITH UL LISTED WIRE HEAD
GUARD(S). DO NOT LOCATE SPRINKLER(S) ABOVE PANEL(S) MOUNTED ON
THE WALL BELOW. SIDEWALL SPRINKLERS SHOWN ARE CONCEPTUAL,
THE CONTRACTOR SHALL INSTALL THE SYSTEM IN ACCORDANCE WITH
THE APPLICABLE CODES, MANUFACTURER'S RECOMMENDATION AND
EQUIPMENT LISTINGS.
SHEET LEGEND:
SIDEWALL SPRINKLER WITH WIRE HEAD GUARD (SEE GENERAL NOTE 1).
1'-4"C TO BLDG EXT (WIRING BY OTHERS)
T1
D1
DOUBLE GANG FACE PLATE
DOUBLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (BLUE IN
COLOR FOR VOICE)
8-POSITION RJ-45
TYPE CAT-6 (GREEN
IN COLOR FOR DATA) BLANK
BLANK
D1
U1
DOUBLE GANG FACE PLATE
DOUBLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (GREEN IN
COLOR FOR DATA)
8-POSITION RJ-45
TYPE CAT-6 (WHITE IN
COLOR FOR ACN) BLANK
BLANK
1D 1U
T1
D1
DOUBLE GANG FACE PLATE
DOUBLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (BLUE IN
COLOR FOR VOICE)
8-POSITION RJ-45
TYPE CAT-6 (GREEN
IN COLOR FOR DATA) 8-POSITION RJ-45
TYPE CAT-6 (GREEN
IN COLOR FOR DATA)
8-POSITION RJ-45
TYPE CAT-6 (BLUE IN
COLOR FOR VOICE)
U1
T2
D2
U2
8-POSITION RJ-45
TYPE CAT-6 (WHITE IN
COLOR FOR ACN)
8-POSITION RJ-45
TYPE CAT-6 (WHITE IN
COLOR FOR ACN)
#D #V #U
T1
SINGLE GANG FACE PLATE
SINGLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (BLUE IN
COLOR FOR VOICE) T1
SINGLE GANG FACE PLATE
SINGLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (GREEN IN
COLOR FOR DATA)
D1
U1
DOUBLE GANG FACE PLATE
DOUBLE GANG OUTLET BOX
8-POSITION RJ-45
TYPE CAT-6 (GREEN IN
COLOR FOR DATA)
8-POSITION RJ-45 TYPE
CAT-6 (WHITE IN COLOR
FOR ACN)
#D #U
D2
U2
BLANK
L28
L28
DOUBLE GANG SIMPLEX FLUSH
MOUNT SIX-PORT MODULAR FACE
PLATE (SIX CABLE CONFIGURATION)
8-POSITION, BLUE RJ-45 TYPE JACK
TERMINATED IN A T568A WIRING
CONFIGURATION. (TYPICAL OF 2)
8-POSITION, GREEN RJ-45 TYPE JACK
TERMINATED IN A T568A WIRING
CONFIGURATION. (TYPICAL OF 2)
OUTLET LABEL, SIMLAR TO SHEET
T-502, SEE SHEET FOR LABELING
STANDARDS
CAT-6 VOICE CABLES (BLUE)
CAT-6 DATA CABLES (GREEN)
PATCH PANEL NUMBER SHALL BE
LABELED AS "LXX" WHERE "XX" IS
THE LOWER LEFT MOUNTING
SPACE OF THE PATCH PANEL
(SPACE 28 INDICATED)
48 PORT PANEL FOR VOICE
JACKS (BLUE CABLES & JACKS)
T568A CONFIGURATION RATED
FOR CAT-6 PERFORMANCE
PORT DESIGNATOR TO MATCH
OUTLET LABEL, SEE SHEET T-502 FOR
LABELING STANDARDS
PATCH PANEL NUMBER SHALL BE
LABELED AS "LXX" WHERE "XX" IS
THE LOWER LEFT MOUNTING
SPACE OF THE PATCH PANEL
(SPACE 28 INDICATED)
48 PORT PANEL FOR DATA
JACKS (GREEN CABLES & JACKS)
T568A CONFIGURATION RATED
FOR CAT-6 PERFORMANCE
PORT DESIGNATOR TO MATCH
OUTLET LABEL, SEE SHEET T-502 FOR
LABELING STANDARDS
L288-POSITION, WHITE RJ-45 TYPE JACK
TERMINATED IN A T568A WIRING
CONFIGURATION. (TYPICAL OF 2)
PATCH PANEL NUMBER SHALL BE
LABELED AS "LXX" WHERE "XX" IS
THE LOWER LEFT MOUNTING
SPACE OF THE PATCH PANEL
(SPACE 28 INDICATED)
48 PORT PANEL FOR ACN
JACKS (WHITE CABLES & JACKS)
T568A CONFIGURATION RATED
FOR CAT-6 PERFORMANCE
PORT DESIGNATOR TO MATCH
OUTLET LABEL, SEE SHEET T-502 FOR
LABELING STANDARDS
CAT-6 ACN CABLES (WHITE)
NOTES:
1. WALL MOUNTED PHONE
OUTLET DETAIL. INSTALL
48" AFF.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-501
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NOT TO SCALEF1 TELECOM OUTLET DETAIL
NOT TO SCALEF6 DATA OUTLET DETAIL (DU TYPE)
NOT TO SCALEF3 TELECOM OUTLET DETAIL (DVU TYPE)
NOT TO SCALED1 VOICE ONLY OUTLET DETAIL
NOT TO SCALED3 DATA ONLY OUTLET DETAIL
NOT TO SCALED6 DATA OUTLET DETAIL (DU - MULTIPLE TYPE)
12" = 1'-0"A1 TYPICAL TELECOM OUTLET DETAIL
NOT TO SCALEE8 TELECOM WALL OUTLET MOUNTING PLATE
/PES-HI)
/PES-HI)
EIGHT-POSITION JACK
W-G G-W W-O BL-W W-BL O-W W-BR BR-W
2 3 4 5 6 7 81
PAIR 4PAIR 1PAIR 3
PAIR 2
LOCATION CODE IDENTIFIER
(UNIQUE FOR EACH CATV OUTLET)
147 / 105.01.TV1
ORIGINATING TELECOMMUNICATIONS
ROOM NUMBER (TELECOM 1A, ROOM
147 INDICATED)
END USER ROOM NUMBER(ROOM 105 INDICATED)
END USER DROP NUMBER(DROP 01 INDICATED)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-502
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NTSA1 BUILDING CABLING SYSTEM LABELING MATRIX
NOT TO SCALEE7 PIN/PAIR ASSIGNMENT (T568A)
12" = 1'-0"C7 CATV OUTLET LABEL DETAIL
SPACE
POWER STRIP
(HORIZONTAL DATA)
48-PORT CAT-6 PATCH PANEL
12-PORT FOC DIST. PNL - DATA (2U)
GFGI 48 PORT NEW. SW-DATA (1U)
CABLE MANAGEMENT
VOICE/DATA CABINET - 102.01
(110 BLOCK TO CAT6)
48-PORT PATCH PANEL - VOICE (2U)
CABLE MANAGEMENT
(HORIZONTAL CAT6)
CABLE MANAGEMENT
CABLE MANAGEMENT
48-PORT PATCH PANEL - VOICE (2U)
FRONT VIEW SIDE VIEW TOP/BOTTOM VIEW
ISOMETRIC VIEW
TWO FAN UNITS VENTILATION
TOP OR BOTTOM MOUNTING
CENTER SWING SECTION
20" RACK SPACED 2 PAIR
MOUNTING RAILS TAPPED #12-24
INDEPENDENT LOCKING
FRONT DOOR AND REAR SECTION
FRONT DOOR
3/4", 1 1/2" AND 2 1/2" NOMINAL
CONCENTRIC CONDUIT
KNOCKOUTS AND HORSESHOE
KNOCKOUTSTOP AND BOTTOM
REAR SECTION
CONTINUOUS HINGES ON
FRONT DOOR AND REAR SECTION
REAR SECTION
3/4", 1 1/2" AND 2 1/2"
REAR SECTION NOMINAL
CONCENTRIC CONDUIT
KNOCKOUT
3/4", 1 1/2" AND 2 1/2" REAR SECTION
NOMINAL CONCENTRIC CONDUIT
KNOCKOUT AND HORSESHOE
KNOCKOUT
KEYHOLE
MOUNTING SIDE VENTILATION
TWO FAN UNITS
MOUNTING
16"
18"
21"
29" 5"
11"
22" 3"
11"
SPACE
POWER STRIP
(HORIZONTAL DATA)
48-PORT CAT-6 PATCH PANEL
12-PORT FOC DIST. PNL - DATA (2U)
GFGI 48 PORT NEW. SW-DATA (1U)
CABLE MANAGEMENT
ACN CABINET
L28
DOUBLE GANG SIMPLEX FLUSH
MOUNT TWO-PORT MODULAR FACE
PLATE (FOUR CABLE CONFIGURATION)
8-POSITION, WHITE RJ-45 TYPE JACK
TERMINATED IN A T568A WIRING
CONFIGURATION. (TYPICAL OF 2)
BLANK
OUTLET LABEL, SIMLAR TO SHEET
T-502, SEE SHEET FOR LABELING
STANDARDS
CAT-6 ACN CABLE (WHITE)
PATCH PANEL NUMBER SHALL BE
LABELED AS "LXX" WHERE "XX" IS
THE LOWER LEFT MOUNTING
SPACE OF THE PATCH PANEL
(SPACE 28 INDICATED)
48 PORT PANEL FOR ACN
JACKS (WHITE CABLES & JACKS)
T568A CONFIGURATION RATED
FOR CAT-6 PERFORMANCE
PORT DESIGNATOR TO MATCH
OUTLET LABEL, SEE SHEET T-502 FOR
LABELING STANDARDS
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-503
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NOT TO SCALEE4 CABINET ELEVATION
NOT TO SCALEA1 TELECOM CABINET - WALL MOUNTED TYPE
NOT TO SCALEE1 CABINET ELEVATION
12" = 1'-0"C5 WIRELESS ACCESS POINT (WAP) DETAIL
GENERAL NOTES:
1. TELECOM CABINETS LOCATED IN ROOM 102. TELECOM OUTLETS LOCATED IN ROOMS
102, 103 AND NORTH CORNER OF MAINTENANCE BAY 100 WILL LIKELY EXCEED 295" IN
LENGTH IF FED FROM NEAREST TELECOM ROOM. CONNECT OUTLETS IN THESE
LOCATIONS TO TELECOM CABINET.
118.01
(VOICE)
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
118.02
(DATA)
CABLE MANAGEMENT (2U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
48 PORT FOC DIST. PANEL - DATA (4U)
(BACKBONE)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
RACK MOUNTED CABLE
MANAGEMENT PANEL, TYP
48 PORT COPPER PATCH PANEL, TYP
QUAD RECEPTICLE, MOUNTED
TO EQUIPMENT RACK, TYP
POWER STRIP W/ SURGE PROTECTION
AND 20 AMP RATED RECEPTICLES, TYP
133.01
(VOICE)
SPACE
POWER STRIP (1U)
CABLE MANAGEMENT (2U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
(GFGI) 48 PORT NET. SW. - DATA (1U)
SPACE
POWER STRIP (1U)
12 PORT FOC DIST. PANEL - DATA (2U)
(GFGI) (OSP)
48 PORT FOC DIST. PANEL - DATA (4U)
(BACKBONE)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U) SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
133.02
(DATA)
133.03
PA/SPARE
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
RACK MOUNTED CABLE
MANAGEMENT PANEL, TYP
48 PORT COPPER PATCH PANEL, TYP
QUAD RECEPTICLE, MOUNTED
TO EQUIPMENT RACK, TYP
POWER STRIP W/ SURGE PROTECTION
AND 20 AMP RATED RECEPTICLES, TYP
138.01
(CCTV)
138.02
(ACN)
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
(GFGI) 48 PORT NET. SW. - DATA (1U)
48 PORT FOC DIST. PANEL - DATA (4U)
(BACKBONE)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
RACK MOUNTED CABLE
MANAGEMENT PANEL, TYP
QUAD RECEPTICLE, MOUNTED
TO EQUIPMENT RACK, TYP
POWER STRIP W/ SURGE PROTECTION
AND 20 AMP RATED RECEPTICLES, TYP
12 PORT FOC DIST. PANEL - DATA (2U)
(GFGI)
143.01
(VOICE)
143.02
(DATA)
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
SPACE
POWER STRIP (1U)
VE
R
TI
C
AL
C
AB
LE
M
AN
AG
EM
EN
T
CABLE MANAGEMENT (2U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
48 PORT FOC DIST. PANEL - DATA (4U)
(BACKBONE)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(110 BLOCK TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - VOICE (2U)
(HORIZONTAL TO CAT-6)
CABLE MANAGEMENT (2U)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
48 PORT PATCH PANEL - DATA (2U)
(HORIZONTAL CAT-6)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
(GFGI) 48 PORT NET. SW. - DATA (1U)
RACK MOUNTED CABLE
MANAGEMENT PANEL, TYP
48 PORT COPPER PATCH PANEL, TYP
QUAD RECEPTICLE, MOUNTED
TO EQUIPMENT RACK, TYP
POWER STRIP W/ SURGE PROTECTION
AND 20 AMP RATED RECEPTICLES, TYP
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-504
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NOT TO SCALED1 TELECOMMUNICATIONS EQUIPMENT RACK ELEVATION - TR118
NOT TO SCALED6 TELECOMMUNICATIONS EQUIPMENT RACK ELEVATION - TR133
NOT TO SCALEA1 TELECOMMUNICATIONS EQUIPMENT RACK ELEVATION - TR138 (ACN EQUIPMENT RM)
NOT TO SCALEA6 TELECOMMUNICATIONS EQUIPMENT RACK ELEVATION - TR143
GENERAL NOTES:
1. RACKS ARE TO BE BONDED TO TELECOM GROUNDING SYSTEM REFER TELECOMMUNICATIONS
GROUNDING SCHEMATIC DIAGRAM ON T-601. SEE BONDING DETAILS ON E8/T-505 AND F5/T-505.
(4) #3 TRANSVERSE
2#3 LONGITUDINAL
2"x2"x1/8" FRAME
3/ 4"
2"
3"
9"
7/8" DIA
TO GROUND BUS BAR FIRST CRIMP
SECOND CRIMP
THIRD CRIMP
FOURTH CRIMP
CRIMPING LOCATION, TYPICAL BOTH ENDS
ALL COMPRESSION
CONNECTORS
CABLE TAGS,
TYPICAL BOTH ENDS
TAGGING NOTES:
1. TAGGING CABLE IS REQUIRED
AT AT BOTH ENDS OF CABLE.
BOLTING HARDWARE MUST BE
SILICONE BRONZE.
CABLE TAGS
NO MORE THAN
1/16" PROTRUDING
FROM END OF LUG.
CLEAR HEAT SHRINK
OMITTED FOR CLARITY.
OPEN SLOT; ENSURE
CABLE IS INSERTED
COMPLETELY INTO
LUG.
No-Ox-ID
COMPOUND
UNDER LUG
GROUND BUS
BAR ASSEMBLY
SILICONE BRONZE
BOLTING HARDWARE
INSPECTION HOLE
DO NOT
DISCONNECT
LEAD
R O
U
TIN
G
TAG
TYPICAL COMPRESSION
CONNECTOR, TYPICAL
BOTH ENDS
GROUND WIRE TO METAL
CONDUITS IN ROOM
GROUND WIRE TO
EXPOSED BUILDING
COLUMN IN ROOM IF
PRESENT
GROUND WIRE TO CATV
ENCLOSURE IN ROOM IF
PRESENT
SEE "DETAIL A1
NOTES", #2
GROUND WIRE TO
PANELBOARD ENCLOSURE
IN ROOM
GROUND WIRE TO CABLE
TRAY(S) IN ROOM
GROUND WIRE TO
BUILDING OUTSIDE
PLANT CONDUITS
STAND-OFF INSULATOR
MOUNTED TO WALL.
TYPICAL FOR TWO
LOCATIONS
GROUND WIRE TO
PROTECTIVE ENTRANCE
TERMINALS IN ROOM IF
PRESENT
FOR TMGB: GROUND
WIRE TO
UNDERGROUND
CONDUIT STUB-UPS
COPPER TMGB SIZE: 4" HIGH
BY 1/4" THICK BY 24" LONG
MINIMUM
DETAIL A1 NOTES:
1. SEE EG601 FOR GROUND CONDUCTOR SIZES.
2. PROVIDE TWO-HOLE BOLTED CONNECTORS
WITH GROUND RATED BELLEVILLE WASHERS
BETWEEN BUS AND CONNECTOR PROVIDE
CONDUCTIVE GREESE BETWEEN BUS AND
CONNECTIONS. PROVIDE FULL WRAP STRAP
CONNECTORS. CLAMPING OF THE STRAPS
SHALL BE WITH FULL SURFACE CLAMPING TOOL
TO INSURE EVEN COMPRESSION AROUND THE
CABLE.
FOR TMGB: GROUND WIRE TO BUILDING
MAIN ELECTRICAL SERVICE.
FINISHED FLOOR
9"
GROUND WIRE TO METAL
CONDUITS IN ROOM
GROUND WIRE TO
EXPOSED BUILDING
COLUMN IN ROOM IF
PRESENT
GROUND WIRE TO CATV
ENCLOSURE IN ROOM IF
PRESENT
SEE "DETAIL A5
NOTES", #2
GROUND WIRE TO
PANELBOARD ENCLOSURE
IN ROOM
GROUND WIRE TO CABLE
TRAY(S) IN ROOM
STAND-OFF INSULATOR
MOUNTED TO WALL.
TYPICAL FOR TWO
LOCATIONS
GROUND WIRE TO
PROTECTIVE ENTRANCE
TERMINALS IN ROOM IF
PRESENT
GROUND WIRE TO
THROUGH-FLOOR
CONDUITS IF PRESENT
COPPER TMGB SIZE: 2" HIGH
BY 1/4" THICK BY 24" LONG
MINIMUM
DETAIL A5 NOTES:
1. SEE T-601 FOR GROUND CONDUCTOR SIZES.
2. PROVIDE TWO-HOLE BOLTED CONNECTORS
WITH GROUND RATED BELLEVILLE WASHERS
BETWEEN BUS AND CONNECTOR PROVIDE
CONDUCTIVE GREESE BETWEEN BUS AND
CONNECTIONS. PROVIDE FULL WRAP STRAP
CONNECTORS. CLAMPING OF THE STRAPS
SHALL BE WITH FULL SURFACE CLAMPING TOOL
TO INSURE EVEN COMPRESSION AROUND THE
CABLE.
GROUND WIRE TO
UNDERGROUND CONDUIT
STUB-UPS IF PRESENT
GROUND WIRE TO TMGB
(OR TR TGB AS IDENTIFIED)
FINISHED FLOOR
9"
SUPPORT BRACKET
GROUND WIRE TO
EQUIPMENT
WALL
STAND-OFF INSULATOR
MOUNTED TO WALL
1/4" THICK BY 24"
LONG COPPER
GROUND BUS
GROUND WIRE TO
EQUIPMENT
GENERAL SHEET NOTES
1. GROUND CONDUCTOR SIZES ARE IDENTIFIED AS MINIMUMS. PROVIDE
ACTUAL CABLE SIZE BASED ON ACTUAL CABLE ROUTING AND ANSI
J-STD-607A STANDARDS IF LARGER.
2. ALL GROUND CABLES SHALL BE LABELED AT BOTH ENDS.
3. ALL GROUNDING CONDUCTORS ARE NOT SHOWN. SEE PLANS AND
SPECIFICATIONS FOR ADDITIONAL GROUNDING CONDUCTORS OR
REQUIREMENTS.
4. PROVIDE EXOTHERMIC WELD CONNECTIONS AND BOLTED LUG
CONNECTIONS AT GROUND BARS AS PER SPECIFICATIONS.
INCORRECT CONNECTION
NOT ACCEPTABLE
GROUND WIRE FROM OTHER
GROUND BARS, EQUIPMENT
GROUNDS, ETC.
TO GROUNDING ELECTRODE
GROUND WIRE FROM OTHER
GROUND BARS, EQUIPMENT
GROUNDS, ETC.
CORRECT
CONNECTION
TO GROUNDING ELECTRODE
SURFACE RACEWAY,
SCHEDULE 40 PVC
18"
CABLE RUNWAY AND TELECOM
RACK ASSEMBLY AND GROUNDING
ANGLE BRACKET, TYP
CUT TO APPROPRIATE
LENGTH, TYP
END CAPS, TYP
EACH RACK SHALL BE
INDIVIDUALLY BONDED TO
TELECOM ROOM GROUND
BAR USING #6 AWG.
CABLE RUNWAY, TYP
NOTES:
1. SCRAPE ANY PAINT TO EXPOSE ANY
METAL BEFORE BONDING LADDER
RACK INDIVIDUAL COMPONENTS.
BOND TO RACK. SEE
DETAIL E8 ON THIS SHEET
TELECOM RACK, TYP
BOND INDIVIDUAL CABLE
RUNWAY COMPONENTS
USING #6 AWG, TYP
GROUND LUG INSTALLATION NOTES:
STAR WASHERS
TELECOM RACK/CABINET
1/0351-400
401-500 2/0
GROUND WIRE RESISTANCE TABLE
FEET
101-160
UP TO 100
DISTANCE
251-350
161-250
AWG NO.
WIRE DIA.
GROUND LUG
1. INSTALL THE GROUND LUG AT A CONVENIENT LOCATION AT THE TOP OR
BOTTOM OF THE RACK/CABINET, USING AN EXISTING HOLE IN THE
RACK/CABINET. IF THERE IS NO CONVENIENT HOLE, DRILL A 5/16 IN. HOLE IN
THE SIDE OR BACK OF THE RACK/CABINET.
2. THE MOUNTING LOCATION CHOSEN SHALL BE THE SHORTEST ROUTE TO THE
GROUND POINT.
3. INSTALL THE LUG AS SHOWN. THE STARWASHERS MUST CONTACT THE LUG
ON ONE SIDE AND THE MOUNTING RAIL ON THE OTHER SIDE (THE
STARWASHERS SHALL PIERCE ANY COATING ON THE RACK/CABINET).
4. INSTALL A #6 AWG STRANDED, GREEN INSULATED COPPER CONDUCTOR
FROM THE RACK/CABINET GROUND LUG TO THE NEAREST SUITABLE GROUND
POINT AS DESCRIBED ABOVE. IF THERE IS NO SUITABLE GROUND POINT
WITHIN 100 FT OF THE RACK/CABINET, THE WIRE SIZE MUST BE INCREASED AS
SHOWN IN TABLE BELOW:
5. INSTALL ONLY ONE GROUND LUG ON THE RACK/CABINET.
6. SCRAPE ANY PAINT TO EXPOSE ANY METAL BEFORE GROUNDING LUG IS
CONNECTED AND USE ANTI-OXIDANT COMPOUND IN ALL GROUNDING
CONNECTIONS.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-505
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NOT TO SCALEF1 HANDHOLE COVER DETAIL
NOT TO SCALEF3 PULLING IRON DETAILS
NOT TO SCALED1 CRIMPING AND TAGGING DETAIL
NOT TO SCALEA1 TELECOMMUNICATION MAIN GROUND BAR (TMGB) DETAIL
NOT TO SCALEA5 TYPICAL TELECOMMUNICATION GROUND BAR (TGB)
NOT TO SCALEA8 TYPICAL GROUND BAR SIDE VIEW
NOT TO SCALED5 GROUND BAR CONNECTION DETAIL
NOT TO SCALEF5 CABLE RUNWAY & TELECOM RACK ASSY/GROUND
NOT TO SCALEE8 RACK/CABINET GROUND DETAIL
PRIME COAT
EXST SUBBASE COURSE
EXST BASE COURSE
COMPACTED BACKFILL
COMPACT THE TOP 6" OF
ALL SUBGRADE CUTS TO A
MIN OF 90% OF MAX DENSITY
FOR COHESIVE MATERIAL &
95% OF MAX DENSITY FOR
COHESIONLESS MATERIAL
SAW CUT, TYP
SEE CIVIL
DRAWINGS
EXST AC SURFACE
DETECTABLE
WARNING TAPE
CONCRETE ENCASED DUCT
AS INDICATED IN PLAN
NEW 12" THK BASE COURSE OR
TO MATCH SITE CONDITIONS
AC SURFACE COURSE OR TO
MATCH SITE CONDITIONS
1. USE CONDUIT SIZES INDICATED IN TELECOM SHEETS TS101 AND TS102.
NOTES:
PROVIDE BITUMINOUS
TACK COAT @ JOINTS
12" MIN
" M
IN
3"
"-1
6"
FINISHED
GRADE
COMPACTED BACKFILL
DETECTABLE WARNING TAPE
CONCRETE ENCASED CONDUIT
AS INDICATED ON PLAN
" M
IN
"-1
6"
3"
WIDTH VARIES
CONC SIDEWALK
SAW CUT
BASE COURSE
12"
MIN
12"
MIN
EXST CONC
SIDEWALK
SEE
CIVIL
DWG
" M
IN
DETECTABLE
WARNING TAPE
CONCRETE ENCASED
CONDUIT SIZE &
QUANTITY AS INDICATED
ON THE SITE PLAN
COMPACTED BACKFILL
TRENCH WIDTH
3"
PVC CONDUIT SIZE AS
REQD, CATV DUCTS
DO NOT REQUIRE
INNERDUCT
3" 3"
3" 3"
FIBER MESH INNERDUCT, 3 INCH
CELLS BY 3 CELLS, ONE PER DUCT,
PER DUCT BANK MIN, TYP
3" 2"
3" 3"
3"
3" 2"
3" 3"
2"
2"
PERMANENT TRACER WIRE, TYP,
SHALL BE INSTALLED IN ALL NEW
DUCT BANKS. ONE TRACER WIRE
SHALL BE INSTALLED PER DUCT BANK.
TRACER WIRE SHOULD BE INSTALLED
AS CENTRICALLY AS POSSIBLE IN THE
TOP CONDUIT FORMATION
3"
3" 2" 2" 2" 3"
3" 3"
2"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-506
TE
LE
C O
M M
U N
IC
AT
IO
N
S D
ET
AI
LS
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
NOT TO SCALEE1 DUCT SECTION (TRAFFIC AREA)
NOT TO SCALEE4 DUCT SECTION (NON-TRAFFIC AREA)
NOT TO SCALEE7 DUCT SECTION (CONCRETE SIDEWALK)
1 1/2" = 1'-0"A1 DUCT (1-WAY CONC ENCASED)
1 1/2" = 1'-0"A4 DUCT (2-WAY CONC ENCASED)
1 1/2" = 1'-0"A6 DUCT (5-WAY CONC ENCASED)
1 1/2" = 1'-0"A8 DUCT (5-WAY CONC ENCASED, 1x5)
GENERAL NOTES:
1. TELECOMMUNICATION CONDUITS AND FABRIC MESH INNER DUCTS SHALL BE
EQUIPPED WITH PULL ROPE PER IAW I3A (2010) SECTION 3.7.4.6.
2. CONCRETE ENCASE PER I3A.
4 NEW 4" CONDUIT TO
HANGAR BLDG, RM 133
4 NEW 4" CONDUIT TO
EXST TMH-02C
MIN
3"
7' - 0" 6' - 0"
7'
0"
1 NEW 4" CONDUIT TO HANGAR BLDG,
RM 133 RESERVED FOR CATV
1 NEW 4" CONDUIT TO EXST TMH-02C,
RESERVED FOR CATV
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
T-510
TE
LE
C O
M M
U N
IC
AT
IO
N
S M
AI
N
TE
N
AN
C
E H
AN
D
H O
LE
D
U C
T
FO
R M
AT
IO
N S
FY
M C
A
PN
AI
R C
R
AF
T M
AI
N
TE
N
AN
C
E H
AN
G
AR
H
O N
O
LU
LU
D
IS
TR
IC
T
FT
. S
H
AF
TE
R
, H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
J.
K
R O
O K
M . S
TA
N
SB
U
R Y
KAKC
J
AN
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
3/8" = 1'-0"C1 NEW MAINTENANCE HOLE
STRUCTURAL NOTES
TELCOM MAINTENANCE HOLE GENERAL NOTES:
1. MAINTENANCE HOLE DESIGNED IN ACCORDANCE WITH AASHTO H-20 LRFD TRAFFIC BRIDGE LOADING USING 5,500 PSI COMPRESSIVE STRENGTH CONCRETE AND 60,000 PSI YIELD STRENGTH ASTM A-615 OR A-706 STEEL
REINFORCEMENT PER CALCS. NO. 612-401-33.
2. LIMIT OF COVER OVER ROOF SECTION IS 1'-6" TO 5'-0". WATER TABLE BASED ON THREE FEET.
3. MAINTENANCE HOLE TO BE PLACED ON A MIN. 6" BASE OF AGGREGATE BASE COURSE FOR EASE OF INSTALLATION
AND EVEN LOAD DISTRIBUTION.
4. INTERIOR CONCRETE BUG HOLES TO BE HAND SACKED PRIOR TO BEING PAINTED.
5. ALL WALLS SHALL BE PAINTED WHITE.
6. PRODUCTS TO BE STENCILED: (INSIDE COLLAR SECTION BELOW FRAME FACING SHORT WALLS, 3" LETTERING)
MAINTENANCE HOLE NUMBER
7. CONDUIT PENETRATIONS ARE APPROXIMATE.
8. CONTRACTOR TO :
A. VERIFY ALL SIZES AND LOCATIONS.
B. VERIFY ALL DIMENSIONS.
C. SUPPLY AND INSTALL ALL PIPING AND ELECTRICAL.
1. CONCRETE - 28 DAY COMPRESSIVE STRENGTH 4,500 PSI.
2. REBAR - ASTM A-615 GRADE 60.
3. MESH - ASTM A-185 GRADE 65.
4. DESIGN ACI-318-95 BUILDING CODE ASTM C-857 MINIMUM STRUCTURAL DESIGN LOADING FOR UNDERGROUND
PRECAST CONCRETE UTILITY STRUCTURES.
5. LOADS - H-20 TRUCK WHEEL WITH 30% IMPACT PER AASHTO 120 PCF SOIL DENSITY.
40 PCF EQUIVALENT FLUID PRESSURE ABOVE WATER TABLE.
80 PCF EQUIVQLENT FLUID PRESSURE BELOW WATER TABLE.
WATER TABLE AT 5'-0"…
This is the start of the file's text. The full file is on GovTribe.