FILE 12 OF 15 06 Plumb Design Complete REV 01-12-2021.pdf

PDF 9 MB Posted

Attached to
FY21 Military Construction Army (MCA) Project Number (PN) 76897 Aircraft, Wheeler Army Airfield, Oahu, Hawaii
Solicitation number
W9128A21R0004
Issued by

About this file

This announcement is a solicitation for a construction contract. The U.S. Army Corps of Engineers is seeking proposals to construct a modified standard design rotary wing aircraft maintenance hangar at Wheeler Army Airfield in Oahu, Hawaii. The project scope includes the hangar, maintenance shops, administrative space, parts and tool storage, hazardous materials storage, petroleum storage, ground support equipment storage, covered storage, hangar access apron, aircraft washing apron, fire pump building, special foundations, cybersecurity measures, building systems, fire protection, intrusion detection, and utility monitoring. Supporting facilities comprise site development, utilities, separate water storage, lighting, paving, parking, drainage, landscaping, and signage. Air conditioning will be provided by self-contained units. Access for individuals with disabilities and sustainability measures are required. The project magnitude is $50-100 million. Proposals will be evaluated on experience, past performance, organization, small business participation plan, and price using best value tradeoff procedures. The contract award is fixed price.

View the file

Other files

File Type Posted
sf30-21r4-am-0010.pdf PDF
sf30-21r4-am-0009.pdf PDF
Drawings-am-0009.pdf PDF
Drawings-am-0008.pdf PDF
sf30-21r4-am-0008.pdf PDF
sf30-21r4-am-0007.pdf PDF
Drawings-am-0007.pdf PDF
Drawings am-0006.pdf PDF
sf30-21r4-am-0006.pdf PDF
Drawings-am-0005.pdf PDF
sf30-21r4-am-0005.pdf PDF
sf30-21r4-am-0004.pdf PDF
Specifications-am-0003.pdf PDF
sf30-21r4-am-0003.pdf PDF
Drawings-am-0003.pdf PDF
sf30-21r4-am-0002.pdf PDF
Drawings-am-0002.pdf PDF
sf30-21r4-am-0001.pdf PDF
DESIGN COMPLETE REV SPECS PN76897 VOL 1.pdf PDF
FILE 9 OF 15 04 Arch Design Complete Rev 01-12-2021.pdf PDF
DESIGN COMPLETE REV SPECS PN76897 VOL 2.pdf PDF
FILE 6 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 1 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 2 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 7 OF 15 03 Struct Design Complete Rev 01-12-2021.pdf PDF
FILE 5 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 11 OF 15 05 Mech Design Complete REV 01-12-2021.pdf PDF
FILE 15 OF 15 09 Telecomm Design Complete REV 01-12-2021.pdf PDF
FILE 3 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 8 OF 15 04 Arch Design Complete Rev 01-12-2021.pdf PDF
FILE 4 OF 15 02 Civil Design Complete Rev 01-12-2021.pdf PDF
FILE 13 OF 15 07 Fire Protection DESIGN COMPLETE REV 01-12-2021.pdf PDF
FILE 10 OF 15 04 Arch Design Complete Rev 01-12-2021.pdf PDF
21r4-RFP solicitation.pdf PDF
FILE 14 OF 15 08 Elec Design Complete REV 01-21-2021 (reduced).pdf PDF
FILE 0 OF 15 Title Sheets G Design Complete Rev 01-12-2021.pdf PDF
DESIGN COMPLETE REV SPECS PN76897 VOL 3.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PLUMBING LEGEND

SYMBOL ABBRV. DESCRIPTION

U/G UNDERGROUND

BALANCING VALVE

CD CONDENSATE DRAIN

CO CLEANOUT

SS SANITARY SEWER

V VENT

WCO WALL CLEANOUT

T/P T/P RELIEF VALVE

UNION, THREADED

RPBP REDUCED PRESSURE BACKFLOW PREVENTER

SS

SD STORM DRAIN

SP SUMP PUMP

RD ROOF DRAIN

AAV AUTOMATIC AIR VENT

A AMPS

AFF ABOVE FINISHED FLOOR

AP ACCESS PANEL

ADJ ADJACENT

AFG ABOVE FINISHED GRADE

APPROX APPROXIMATE

ASSY ASSEMBLY

AV AIR VENT

ABV ABOVE

AI ANALOG INPUT

AO ANALOG OUTPUT

BFF BELOW FINISHED FLOOR

BFP BACKFLOW PREVENTER

BLDG BUILDING

BLW BELOW

BOT BOTTOM

BTWN BETWEEN

BV BALL VALVE

BYP BY PASS

BI BINARY INPUT

BO BINARY OUTPUT

SYMBOL ABBRV. DESCRIPTION

CHKV CHECK VALVE

CLG CEILING

CONT CONTINUATION

CONC CONCRETE

CW COLD WATER

DN DOWN

DEG DEGREE

DEMO DEMOLITION

DET DETAIL

DIA, Ø DIAMETER

ELEV ELEVATOR

EFF EFFICIENCY

EQUIP EQUIPMENT

EQUIV EQUIVALENT

EXST EXISTING

CD

BFP

AV

MAX

FD FLOOR DRAIN

°F FAHRENHEIT

FF FINISH FLOOR

FLA FULL LOAD AMPS

FLR FLOOR

FT FEET

FT WG FEET OF WATER GAUGE

GALVANIZEDGALV

GA GAUGE

GAL GALLON

GLOBE VALVEGLV

GOVERNMENTGOVT

GALLONS PER MINUTEGPM

GATE VALVEGTV

HAND-OFF-AUTOHOA

HORSEPOWERHP

HEIGHTHT

HOT WATER SUPPLYHW

HERTZHZ

HOURHR

INDIRECT DRAINID

INCHES OF WATER GAUGEIN WG

INVERTINV

ISOMETRICISO

KILOWATTKW

POUNDSLBS

LEAVINGLVG

LEAVING WATER TEMPERATURELWT

MAXIMUMMAX

THOUSAND BTUHMBH

MINIMUM CIRCUIT AMPSMCA

MECHANICALMECH

WATER METERM

MINUTE; MINIMUMMIN

NORMALLY CLOSEDNC

NOT IN CONTRACTNIC

NORMALLY OPEN; NUMBERNO

NOT TO SCALENTS

ON CENTERO.C.

OCCUPANCY SENSOROCC

OUTSIDE DIAMETEROD

PRESSURE DROPPD

PHASEPH

PRV

QTY

PRESSURE RELIEF VALVE

QUANTITY

ROOMRM

RATED LOAD AMPSRLA

REQUIREDREQ'D

PSI POUNDS PER SQUARE INCH

M

FCO FLOOR CLEANOUT

COTG CLEANOUT TO GRADE

HOSE BIBB / WALL HYDRANTHB

SHUT OFF VALVESOV

STANDARDSTD

SCHEDULESCH.

SYSTEMSYS

SIMILARSIM

SPECIFICATIONSPEC

THERMOMETER

TEMPERATURETEMP

TO FLOOR ABOVETFA

TO FLOOR BELOWTFB

TOP OF FINISH FLOORTFF

THICKTHK

THROUGHTHRU

TEMPERATURE SENSORTS

TYPICALTYP

VOLTV

VERTICALVERT

WATTW

WITHW/

WITHOUTW/O

WATER HEATERWH

WORKING PRESSUREWPR

WEIGHTWT

WATER HAMMER ARRESTORWHAWHA

NEW WORK

HOT WATER RETURNHWR

STRAINER, INLINE

T

UNION, FLANGED

PRESSURE GAUGE AND COCK

PIPE INTO PLANE, DOWN

PIPE OUT OF PLANE, UP

PIPE DIRECTION CHANGE

PIPE BRANCH, OUT OF PLANE

PIPE BRANCH, INTO PLANE

PIPE BRANCH IN PLANE

INDUSTRIAL WASTEIW INDUSTRIAL WASTEIW

GOVT FURNISHED GOVT INSTALLEDGFGI

SYMBOL

VENT TO ROOFVTR

ABBRV. DESCRIPTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-001

PL

U

M

BI

N G

A

BB

R

EV

IA

TI

O N

S, L

EG

EN

D , A

N D

G

EN

ER

AL

N O

TE

S

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

PLUMBING GENERAL NOTES

1. THE ENTIRE INSTALLATION SHALL COMPLY WITH INTERNATIONAL PLUMBING CODE (IPC) UNIFIED FACILITIES CRITERIA (UFC)

AND REQUIREMENTS LISTED IN CONTRACT DOCUMENTS.

2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER THE COMPLETE INSTALLATION OF SYSTEMS TO FUNCTION AS

DESCRIBED AND SPECIFIED. THE OMISSION OF REFERENCE TO ANY NECESSARY ITEM OF LABOR OR MATERIAL SHALL NOT

RELIEVE THE CONTRACTOR FROM PROVIDING SUCH LABOR AND MATERIAL.

2. PRIOR TO BIDDING, CONTRACTOR SHALL PARTICIPATE IN A SITE-INSPECTION TO GAIN A FAMILIARITY WITH THE LEVEL OF

DIFFICULTY INVOLVED WITH THIS PROJECT.

3. ALL EQUIPMENT SHALL BE CAPABLE OF FITTING INTO THE SPACES ALLOCATED WHILE MEETING THE MANUFACTUER'S RECOMMENDED ACCESS REQUIREMENTS. REVIEW ALL SPACES WHERE EQUIPMENT IS TO BE INSTALLED PRIOR TO ORDERING OF EQUIPMENT AND NOTIFY THE ENGINEER OF ANY INADEQUATE CLEARANCES OR CONDITIONS THAT WILL PREVENT THE

PROPER INSTALLATION, MAINTENANCE, AND OPERATION OF EQUIPMENT.

4. COORDINATE WITH OTHER TRADES PRIOR TO COMMENCING WORK AND DURING CONSTRUCTION. OVERLAY PLANS AND CHECK

FOR ANY DISCREPANCIES OR CONFLICTS WITH OTHER TRADES.

4. NO ASBESTOS OR LEAD CONTAINING MATERIALS SHALL BE USED IN THIS PROJECT.

4. COORDINATE EXACT LOCATION OF ROOF PENETRATIONS WITH ROOF STRUCTURE. ALL PENETRATIONS TO BE A MIN. 1'-6"

FROM WALLS, CURBS, PIPES, VENT STACKS, AND OTHER ROOF PENETRATIONS.

5. VERIFY AND COORDINATE ALL WALL AND FLOOR PENETRATIONS WITH THE STRUCTURAL AND ARCHITECTURAL DRAWINGS

PRIOR TO THE START OF CONSTRUCTION.

6. OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING ANY PENETRATIONS THROUGH STRUCTURAL

MEMBERS, WALLS, AND SLABS.

7. SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK, MARK SUCH CHANGES ON THE AS-BUILT DRAWINGS. IF

THESE CHANGES REQUIRE ALTERNATE METHODS TO THOSE APPROVED BY THE CONTRACT DOCUMENTS, SUBMIT A RFI SHOWING THE PROPOSED ALTERNATE METHODS TO THE GOVERNMENT FOR REVIEW. DO NOT PROCEED UNTIL REVIEWED.

8. LOCATE ALL UTILITY LINES OR OTHER INTERFERENCES IN AREAS OF PROPOSED TRENCH WORK PRIOR TO START OF

EXCAVATION. REPAIR OR PAY FOR ALL DAMAGES TO EXISTING UTILITIES.

9. DRAWINGS DO NOT ATTEMPT TO SHOW EXACT DETAILS OF PIPING. PROVIDE OFFSETS AS NECESSARY TO AVOID LOCAL OBSTRUCTIONS OR INTERFERENCE WITH OTHER TRADES. REVIEW ALL PIPING RUNS PRIOR TO INSTALLATION AND IMMEDIATELY NOTIFY THE GENERAL CONTRACTOR OF ANY INTERFERENCE AND/OR LACK OF ADEQUATE CLEARANCES.

10. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE ALL CAULKING AND SEALANT REQUIRED TO COMPLETE THE INSTALLATION OF ALL PLUMBING FIXTURES AND FITTINGS. SEE CAULKING AND SEALANT SPECIFICATIONS IN CONTRACT

SPECS FOR APPROPRIATE CAULKING AND SEALANT SPECIFICATIONS.

12. PAINT ALL EXPOSED PIPING TO MATCH THE ADJACENT SURFACE.

14. PROPERLY FIRESTOP ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS, OR PARTITIONS WITH A UL APPROVED

SYSTEM APPROPRIATE FOR THE PENETRATION TYPE, FIRE RATING, AND AS SPECIFIED.

15. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, WATER HAMMERS, AND EQUIPMENT. PANELS SHALL BE AS

SPECIFIED. SIZES WILL BE DETERMINED BY SUBCONTRACTORS AS TO WHAT IS NEEDED TO SERVICE OR ACCESS. COORDINATE THE LOCATION OF ACCESS PANELS TO ENSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY. ACCESS PANELS SHOULD BE LOCATED IN CLOSETS, STORAGE AREAS, OR INCONSPICUOUS SPACES TO BE REVIEWED BY THE GENERAL CONTRACTOR ON FINAL LOCATION AND SIZES. THE ACCESS PANELS SHALL MATCH THE FIRE RATING FOR THE WALLS OR

CEILINGS THAT THEY ARE PENETRATING.

16. PROVIDE ISOLATION VALVES ON PIPING BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT. SHOW ALL ISOLATION

VALVES ON THE AS-BUILT DRAWINGS.

17. INSULATE ALL SEWER PIPING RECEIVING AIR CONDITIONING CONDENSATE DRAINS, ICE MACHINE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION FROM POINT OF CONNECTION TO THE TOP OF CONCRETE SLAB-ON GRADE.

INSULATE FLOOR DRAIN AND FLOOR SINK BODIES EXPOSED TO AIR BELOW THE FLOOR.

19 SEE ISOMETRIC DRAWINGS FOR DETAILED WATER, SEWER AND VENT PIPE SIZING.

20 SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND INSTALLATION OF PLUMBING FIXTURES AND EXACT BUILDING

DIMENSIONS.

21 CONTRACTOR TO COORDINATE AND VERIFY SERVICE CONNECTIONS ON ALL FIXTURES.

22 MANIFOLD ALL PLUMBING VENTS ABOVE FLOOD RIM LEVEL OF PLUMBING FIXTURES.

23 ALL WATER RUNS ARE OVERHEAD AND SHALL BE CONCEALED WHERE EVER POSSIBLE. ANY EXPOSED PIPING SHALL BE RUN

AS HIGH AS POSSIBLE AND RUN PARALLEL OR PERPENDICULAR TO BEAMS. SLOPE PIPES TO DRAIN.

24 MECHANICAL WATER HAMMER ARRESTORS SHALL BE LOCATED AS INDICATED ON THE PLAN DRAWINGS AND IN ACCORDANCE

WITH STANDARD PDI-WH201.

25 ALL IN-LINE AND ENDPOINT DEVICES SHALL MEET THE REQUIREMENTS OF NSF 61, SECTIONS 8 AND 9, RESPECTIVELY.

26 ALL VALVES SHALL BE LINE SIZE, UNLESS INDICATED OTHERWISE.

27 THE MAINTENANCE BAYS (RM 131 & RM 132) AND ALL ADJACENT ROOMS THAT OPEN DIRECTLY INTO IT SHALL BE CONSIDERED

CLASS I, DIVISION II HAZARDOUS AREAS UP TO 1'-6" AFF. THE CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT AND

DEVICES A MINIMUM OF 1'-8" AFF UNLESS OTHERWISE INDICATED.

28 CONTRACTOR SHALL COORDINATE ALL GFGI EQUIPMENT WITH USER.

29 WHERE PIPES CROSS OVER CABLE TRAY, PROVIDE A MINIMUM 12" CLEARANCE BETWEEN TOP OF CABLE TRAY AND BOTTOM

OF PIPES.

30 PROVIDE PIPE EXPANSION JOINT CONNECTIONS AS REQUIRED TO ACCOMMODATE MOVEMENT FROM THE BUILDING’S

ISOLATION JOINTS. COORDINATE REQUIRED LOCATIONS WITH ARCHITECTURE AND STRUCTURAL. FOR ISOLATION JOINT LOCATIONS BETWEEN HANGAR MAINTENANCE BAY AND HANGAR ADMINISTRATION WING CMU WALLS, SEE SHEETS S-203 THROUGH S-206 OF STRUCTURAL DRAWINGS. INSTALL EXPANSION JOINTS PER MANUFACTURE’S RECOMMENDATION.

ES

ES

ES

ES

ES

ES

C O

M M

COMM

2.5'

3.0'

13.7'

3.0

3.0

3.0'W

F20

W

W6

W8

F24 SU

C

TIO

N

F16

F24

W

W

W6

F24 W2

W

W 1-1/2

H B

W8 W

W4

W6

F24 F24

W

W8

W

F24 FIR

E LO

O P

F24 F24 F24

HB

W1

W1

HB

W

W8

W8

W 3/4

F8

F6

HB

W1 F24

W

W

W6 F12

F12

F24

W3/4

W3/4

W3/4

W3/4

W3/4

W3/4

W8

FFE=823.68

CARPOOL ONLYCARPOOL ONLY CARPOOL ONLYCARPOOL ONLYCARPOOL ONLY CARPOOL ONLYCARPOOL ONLYCARPOOL ONLYCARPOOL ONLY

MOTORCYCLE

PARKING

D6 D15D15D15

D6

D

D18

D

D15

D24 D

D6

D4 D4

D18

D15

D15

D18 D18

D

D18

D

D18

D

D15

D6

D6

D6

D6

D6 D6 D6

D

D18

D15

D18D15 D6

33" MIN

30" MIN

87" MIN

PF

PFPFPF PF

PF

PF

PF

PFPFPF PF

PF

PF

BF

P

WASH RACKS

CHILLER ENCLOSURE

AMELIA EARHART ROAD

LA

U

H

AL

A R

O

AD

HAZARDOUS MATERIAL STORAGE AND POL STORAGE

PRE-FABRICATED STRUCTURES. SEE SPECIFICATIONS

FOR DETAILS

FUEL OIL STORAGE TANKS,

SEE SHEET M-505

OIL / WATER SEPERATOR,

SEE SHEET P-508

13.1

12111098765432

0.9

K

J

H

G

F

C.9

C

A

1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1

H.1

MATCHLINE A MATCHLINE A

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E B

M

AT

C H

LI

N

E B

P-101 A3

AIRCRAFT MAINTENANCE

HANGAR

G1 G2

GE

GD

GC

GB

GA

GSE/ASIOE

COVERED

STORAGE

BUILDING

P-403 A1

FA

FB

F1 F2FIRE PUMP

BUILDING

P-404 B1

WA

WB

WC

W1 W2

WATER STORAGE

TANK

P-405 D1

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-002

PL

U

M

BI

N G

O

VE

R

AL

L

SI

TE

P

LA

N

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

PLAN NORTH

0 40'20' 80'

SCALE: 1" = 40'-0"

1" = 40'-0"A4 PLUMBING OVERALL SITE PLAN

13.1

121110987654321

0.9

K

J

H

G

F

C.9

C

A

1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1

H.1

CATCH BASIN

MATCHLINE A MATCHLINE A

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E C

M

AT

C H

LI

N

E B

M

AT

C H

LI

N

E B

SEE M-002 FOR CONTINUATION

OF HOT WATER PIPING

AIRCRAFT

MAINTENANCE

BAY

AIRCRAFT PARTS

SUPPLY / 102

AIRCRAFT PARTS

SUPPLY OFFICE /

CORRIDOR 3

157C

PNEUDRALICS

REPAIR SHOP

POWER PLANT/

POWERTRAIN

SHOP

STRUCTURAL

REPAIR SHOP

BLADE REPAIR

SHOP

COMSEC SECURE

STORAGE

AIRLOCK 3

157G

COMPRESSOR

ROOM

MECHANICAL

ROOM

CORRIDOR 1

157A

SHOP SECTION

HQ

PLATOON OFFICE

ORDERLY ROOM

(COMPANY D)

1ST SERGEANT

OFFICE

COMMANDER

OFFICE

AIRCRAFT

MOUNTED

WEAPONS VAULT

SYSTEMS REPAIR

SHOP

AIRLOCK 2

157F

REPAIR SECTION

WORKROOM

AIRFRAME

REPAIR PLATOON

OFFICE

AIRFRAME

REPAIR PLATOON

COMPONENT

REPAIR PLATOON

OFFICE

COMPONENT

REPAIR PLATOON

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

LOGISTICS

ASSISTANCE

REPRESENTATIVES

(LARS)

CONTRACTOR

LOGISTICS

SUPPORT

MECHANICAL

ROOM

FIRE

PROTECTION

SPECIAL TOOLS

ROOM

MEN'S

WOMEN'S

MOTHER'S ROOM

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

PRODUCTION

CONTROL

PRODUCTION

CONTROL OFFICE

QUALITY

CONTROL OFFICE

QUALITY

CONTROL

CORRIDOR 2

157B

CORRIDOR 4

157D

ARMS VAULT

(COMPANY D)

UNIT STORAGE

(COMPANY D)

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) STORAGE

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) SHOP

FACILITY

STORAGE ROOM

CREW CHIEF

WORK ROOM

(COMPANY C)

CREW CHIEF

WORK ROOM

(COMPANY A)

AIRLOCK 1

157E

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

ACN EQUIPMENT

JANITOR

MULTI PURPOSE /

BREAK / CONF

CREW CHIEF

WORK ROOM

(COMPANY B)

HEAVY AIRCRAFT

TRAFFIC RATED

TRENCH DRAIN GRATE

CATCH BASIN CATCH BASIN CATCH BASIN

RECYCLE ROOM

VESTIBULE

155A

3 3 3 3

CAGE

C152

CAGE

C149

CAGE

C147

CAGE

C108B

CAGE

C108A

CAGE

C106

NONDESTRUCTIVE

INSPECTION (NDI)

ROOM

CAGE

C101

OXYGEN

GENERATOR

ROOM

CAGE AREA

CAGE

C125

CAGE

C131

CAGE

C142

A

CD

B E

3" IW, CONNECT TO CIVIL

4" W, CONNECT TO CIVIL

8" IW, CONNECT TO CIVL

4" DCW, CONNECT TO CIVIL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-101

PL

U

M

BI

N G

P

LA

N

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/16" = 1'-0"A3 PLUMBING PLAN - AIRCRAFT MAINTENANCE HANGAR

KEY PLAN

08' 16' 32'4'12'16'

SCALE: 1/16"=1'-0"

PLAN NORTH

KEY NOTES

CREW CHIEF

WORK ROOM

(COMPANY C)

CREW CHIEF

WORK ROOM

(COMPANY B)

CREW CHIEF

WORK ROOM

(COMPANY A)

FACILITY

STORAGE ROOM

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

RECYCLE ROOM

MEN'S

WOMEN'S

SPECIAL TOOLS

ROOM

ELECTRICAL

ROOM

COMMUNICATIONS

ROOM

PRODUCTION

CONTROL

ACN EQUIPMENT

JANITOR

QUALITY

CONTROL

QUALITY

CONTROL OFFICE

PRODUCTION

CONTROL OFFICE

CORRIDOR 4

157D

CORRIDOR 2

157B

ARMS VAULT

(COMPANY D)

UNIT STORAGE

(COMPANY D)

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) STORAGE

AIRCRAFT

MAINTENANCE

BAY

AIRLOCK 1

157E

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) SHOP

P-15

7654321

0.9

C

A

1.9 2.9 3.9 4.4 5.6 6.6

MATCHLINE A

SEE SHEET P-105

MATCHLINE A

SEE SHEET P-105

P-401 D1

1" INSULATED

CONDENSATE

FROM FCU-155

TO P-19

1" INSULATED

CONDENSATE

FROM FCU 133

TO P-7

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

P-13B

P-13 P-9 P-18 P-14

P-9 P-18

P-5

P-18

FCU

FCU

P-18

P-11

1" INSULATED

CONDENSATE

FROM FCU-143

TO P-19

FCU

DH

P-19 P-10

P-13B

2"

IW

2"

IW

3" W

FCU

2" V

IW SLOPE 1/8" / 12" DN.

3" IW 3" IW

W SLOPE 1/8" / 12" DN.

2" W

3" FCO

1" INSULATED

CONDENSATE

FROM FCU 138

TO P-7

1" INSULATED

CONDENSATE

FROM DH-155

TO P-19

2" V

1" CD

1" C

D

1" CD

1" CDVESTIBULE

155A

C D

S

LO

PE

/4

2"

D N

CD SLOPE 1/4" / 12" DN.

SEE P-103

FOR PIPE

CONT.

SEE P-105

FOR PIPE

CONT.

MOTHER'S ROOM

2" VTR

2" VTR

A6 P-303

D1 P-303

P-17

3" COTG

3" FCO

CD SLOPE 1/4" / 12" DN.

2" FCO

3" FCO

2" VTR

2" V

3" CO ON VERTICAL

3" FCO

2" FCO

3" FCO

FIRE

PROTECTION

2"

IW

IW

S

LO

PE

/4

2" D

N

2" FCO

P-7

GFGI WASHER & DRYER

2" W

2" V COMMUNICATIONS

STORAGE

C146A

IW

S

LO

PE

/4

2" D

N

IW SLOPE 1/8" / 12" DN.

3" IW

4" W

2" V

4" W

W

SLO

PE 1/

4"

/ 1 2"

DN.

2"

IW

2" IW

2" IW

A

CD

B E

3" IW, REFER TO CIVIL DWGS FOR CONTINUATION

4" W, REFER TO CIVIL DWGS FOR CONTINUATION

8" IW, REFER TO CIVIL DWGS FOR CONTINUATION

2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE

DETAIL A3/P-506.

12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE

TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH

8" DIAMETER SIDE OUTLET CONNECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-102

PL

U

M

BI

N G

S

AN

IT

AR

Y W

AS

TE

/V

EN

T

PL

AN

AR

EA

"A

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "A"

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.

2. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER FOOT IN DIRECTION INDICATED BY SLOPE ARROWS

3. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

5. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW FOUNDATION FOOTINGS.

6. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

KEYNOTES

SPECIAL TOOLS

ROOM

REPAIR SECTION

WORKROOM

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

FIRE

PROTECTION

MECHANICAL

ROOM

AIRFRAME

REPAIR PLATOON

OFFICE

AIRFRAME

REPAIR PLATOON

COMPONENT

REPAIR PLATOON

OFFICE

COMPONENT

REPAIR PLATOON

13.1

121110987

C.9

C

A

6.6 7.5 8.4 9.4 10.4 12.1

AIRCRAFT

MOUNTED

WEAPONS VAULT

COMSEC SECURE

STORAGE

SYSTEMS REPAIR

SHOP

POWER PLANT/

POWERTRAIN

SHOP

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

LOGISTICS

ASSISTANCE

REPRESENTATIVES

(LARS)

CONTRACTOR

LOGISTICS

SUPPORT

STRUCTURAL

REPAIR SHOP

BLADE REPAIR

SHOP

COMPRESSOR

ROOM

MECHANICAL

ROOM

SHOP SECTION

HQ

PLATOON OFFICE

ORDERLY ROOM

(COMPANY D)

1ST SERGEANT

OFFICE

COMMANDER

OFFICE

AIRCRAFT

MAINTENANCE

BAY

AIRLOCK 2

157F

CORRIDOR 1

157A

CORRIDOR 2

157B

AIRLOCK 3

157G

MATCHLINE A

SEE SHEET P-106

MATCHLINE A

SEE SHEET P-106

1" INSULATED

CONDENSATE

FROM FCU-116

TO P-19 ID

1" INSULATED

CONDENSATE

FROM FCU-132

TO P-18 ID 1" INSULATED

CONDENSATE FROM

FCU-118 TO P-19 ID

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

P-18

P-18

P-18

P-18

FCU

AHU

1" INSULATED

CONDENSATE

FROM AHU-128

TO P-19 ID

P-18

P-18

P-19

4" W

2" W

4" W

4" FCO

FCU

P-10 P-19

DH

116 1/2" INSULATED

CONDENSATE FROM

DH 116 TO P-19 ID

2"

IW

1" CD

P-14

P-18 P-9

P-14

P-18 P-9

P-19

P-13A

MAU

MAU

P-14

P-19 P-10

P-19 P-10

P-19

P-18

AHU

P-13A

P-8

FCU

1" C

D

W S

LO

PE

/8

2" D

N

1" INSULATED

CONDENSATE

FROM MAU-105

TO P-13A

2"

IW

1" INSULATED

CONDENSATE

FROM MAU-108

TO P-13A

3" FCO

1/2" CD

1" C

D

A4 P-302

P-18

1" INSULATED CONDENSATE

FROM AHU-104 TO P-18 ID

CD SLOPE 1/4" / 12" DN.

SEE

P-102

FOR PIPE

CONT.

2" VTR

A4 P-303

4" HUB DRAIN

STAND PIPE.

COORDINATE

WITH FIRE

PROTECTION.

4" W

3" IW

3" FCO

3" FCO

2" FCO

4" FCO

2" WCO

W SLOPE 1/8" / 12" DN.

SEE P-104

FOR PIPE

CONT.

3" IW

P-9

2" FCO 2" FCO

2" FCO

4" VTR

P-19

2" VTR

AD

ART

AC

AC

ERV

2" V

2" V

2" V2" V

2"

IW

2" V

2" V

2" V

1 1/2" V 2" V

2"

IW

3" IW

4" V

4" FCO

2" V

2" V

2" W P-19

P-18

P-19

2" WCO2" CO

3" IW

2"

IW

2"

IW

2" IW

4" FCO

2" W

4" W

4" W

2" W

2" W

2" W2" W

4" W

2" W

2" W

4" W

4" W

P-17

3" W W SLOPE 1/4" / 12" DN.

2" IW

4" W

2" V

2" V

3" W

2" W

1 1/2" VTR

A

CD

B E

3" IW, REFER TO CIVIL DWGS FOR CONTINUATION

4" W, REFER TO CIVIL DWGS FOR CONTINUATION

8" IW, REFER TO CIVIL DWGS FOR CONTINUATION

2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE

DETAIL A3/P-506.

12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE

TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH

8" DIAMETER SIDE OUTLET CONNECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-103

PL

U

M

BI

N G

S

AN

IT

AR

Y W

AS

TE

/V

EN

T

PL

AN

AR

EA

"B

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "B"

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.

2. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.

3. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER FOOT IN DIRECTION INDICATED BY SLOPE ARROWS.

4. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.

5. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY AND DOMESTIC ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

6. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW FOUNDATION FOOTINGS.

7. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

A

CD

B E

BLADE REPAIR

SHOP

PNEUDRALICS

REPAIR SHOP

CORRIDOR 3

157C

AIRCRAFT PARTS

SUPPLY / 102

13.1

H

G

F

C.9

H.1

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

/ P -1

M

AT

C

H

LI

N E

C

SE

E

SH

EE

T

P-

/ P

-1

P-13

3" IW3" IW

IW SLOPE 1/8" / 12" DN.

D4 P-302

3" IW

SEE

P-103

P-104 A1

P-104 D1

PNEUDRALICS

REPAIR SHOP

AIRCRAFT PARTS

SUPPLY OFFICE /

IW

S

LO

PE

/4

2" D

N

2"

IW

2"

IW

2"

IW

1" C

D

C D

S

LO

PE

/4

2"

D N

. 3" IW, REFER TO CIVIL DWGS FOR CONTINUATION

4" W, REFER TO CIVIL DWGS FOR CONTINUATION

8" IW, REFER TO CIVIL DWGS FOR CONTINUATION

2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE

DETAIL A3/P-506.

12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE

TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH

8" DIAMETER SIDE OUTLET CONNECTION

P-10 P-19

P-13A

MAU

2"

IW

1" C

D

2" VTR

CORRIDOR 3

157C

PNEUDRALICS

REPAIR SHOP

1" INSULATED

CONDENSTATE DRAIN

FROM MAU-107 TO P-13A

2"

IW

2" IW

2" FCO

2" V

2" IW

2" IW

1" C

D

CD DOWN TO P-13A

13.1

F

1" CD

FCU

P-9

P-18

2"

IW

CD SLOPE 1/4" / 12" DN.

2" VTR

AIRCRAFT

MAINTENANCE

BAY

AIRCRAFT PARTS

SUPPLY OFFICE /

AIRCRAFT PARTS

SUPPLY / 102

1" INSULATED

CONDENSTATE DRAIN

FROM FCU-102 TO P-13A

2" V

2"

IW

2" IW

2" V

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-104

PL

U

M

BI

N G

S

AN

IT

AR

Y W

AS

TE

/V

EN

T

PL

AN

AR

EA

"C

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"A5 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C"

SHEET NOTES

KEY PLAN

PLUMBING KEYNOTES

1. ALL SANITARY PIPING UNDER SLAB UNLESS

OTHERWISE NOTED.

2. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS

OTHERWISE NOTED.

3. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER

FLOOT IN DIRECTION INDICATED BY SLOPE ARROWS.

4. SLOPE SANITARY PIPEING PER IPC UNLESS

OTHERWISE NOTED.

5. COORDINATE WITH STRUCTURAL AT CONDITIONS

WHERE SANITARY PIPES ARE LOCATED BELOW SLAB

AND PENTRATE THOUGH FOUNDATION WALLS.

6. COORDINATE WITH STRUCTURAL AT CONDITIONS

WHERE SANITARY PIPES RUN BELOW FOUNDATION

FOOTINGS.

7. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE

NOTE 30 ON SHEET P-001.

1/4" = 1'-0"A1 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C" 2

1/4" = 1'-0"D1 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C" 1

02' 4' 8'1'3'4'

SCALE: 1/4"=1'-0"

B E

HEAVY AIRCRAFT TRAFFIC

RATED TRENCH DRAIN GRATE

AIRCRAFT

MAINTENANCE

BAY

CATCH BASIN

INV = -4' - 1 1/2"

7654321

0.9

K

J

H

G

F

MATCHLINE A

SEE SHEET P-102

MATCHLINE A

SEE SHEET P-102

3 3

HEAVY AIRCRAFT TRAFFIC RATED

TRENCH DRAIN GRATE

TRENCH DRAIN: CHANNELS ARE PRE-SLOPED

INTERLOCKING EPS FORMS WITH STANDARD SLOPE OF

0.75%. PROVIDE WITH A GALVANIZED DUCTILE IRON

SLOTTED GRATE CLASS F RATED (DIN 19580/EN 1433). SEE

STRUCTURAL DRAWINGS FOR FURTHER INFORMATION.

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

TRENCH DRAIN

INV = -1' - 3 1/2"

@ HIGH POINT

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 4" @

HIGH POINT

HEAVY AIRCRAFT TRAFFIC RATED

TRENCH DRAIN GRATE

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 3 3/4" @

HIGH POINT

P-9 P-18

2" V

CATCH BASIN

INV = -4' - 1 1/2"

5SEE NOTE

5SEE NOTE

TRENCH DRAIN SLOPETRENCH DRAIN SLOPETRENCH DRAIN SLOPE TRENCH DRAIN SLOPE

TYP.

SEE P-102 FOR

PIPE CONT.

4 TYP.

2" IW

8"

IW

8"

IW

2" IW 2" IW2" IW 2" IW 2" IW 2" IW 2" IW

2"

IW

2" COTG

VENT PIPE

BELOW SLAB

4" VTR

VENT PIPE

BELOW SLAB

4" V

IW

S

LO

PE

/4

2" D

N

2" IW

3" IW, REFER TO CIVIL DWGS FOR CONTINUATION

4" W, REFER TO CIVIL DWGS FOR CONTINUATION

8" IW, REFER TO CIVIL DWGS FOR CONTINUATION

2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE

DETAIL A3/P-506.

12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE

TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH

8" DIAMETER SIDE OUTLET CONNECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-105

PL

U

M

BI

N G

S

AN

IT

AR

Y W

AS

TE

/V

EN

T

PL

AN

AR

EA

"D

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "D"

1. BUILDING FINISHED FLOOR ELEVATION NEAR THE HANGAR DOOR IS 823.60' PER THE CIVIL DRAWINGS.

2. NO UNDERFLOOR PIPING IN HANGAR BAY UNLESS OTHERWISE NOTED.

3. SLOPE TRENCH DRAIN IN THE DIRECTION OF THE SLOPE ARROWS BY 0.75%.

4. PIPING CONNECTED TO THE HANGAR TRENCH DRAINAGE SYSTEM SHALL BE CAST IRON PIPING FROM THE

TRENCH DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.

5. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.

6. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.

7. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.

KEYNOTES

8. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE

LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

9. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW

FOUNDATION FOOTINGS.

10. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

B E

13.1

121110987

K

J

H

G

F

H.1

MATCHLINE A

SEE SHEET P-102

MATCHLINE A

SEE SHEET P-102

3 3

TRENCH DRAIN: CHANNELS ARE PRE-SLOPED

INTERLOCKING EPS FORMS WITH STANDARD SLOPE

OF 0.75%. PROVIDE WITH A GALVANIZED DUCTILE

IRON SLOTTED GRATE CLASS F RATED (DIN 19580/EN

1433). SEE STRUCTURAL DRAWINGS FOR FURTHER

INFORMATION.

AIRCRAFT

MAINTENANCE

BAY

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

CATCH BASIN

INV = -4' - 1 1/2"

TRENCH DRAIN

INV = -1' - 3 3/4" @

HIGH POINT

HEAVY AIRCREAFT TRAFFIC RATED

TRENCH DRAIN GRATE

HEAVY AIRCREAFT TRAFFIC RATED

TRENCH DRAIN GRATE

HEAVY AIRCREAFT TRAFFIC RATED

TRENCH DRAIN GRATE

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

TRENCH DRAIN

INV = -1' - 8" @

LOW POINT

CATCH BASIN

INV = -4' - 1 1/2"

TRENCH DRAIN

INV = -1' - 3 3/4" @

HIGH POINT

TRENCH DRAIN

INV = -1' - 3 1/4"

@ HIGH POINT

P-13

P-9 P-18

2" IW

2" V

2" V

SEE P-104

FOR PIPE

CONT.

5SEE NOTE

5SEE NOTE P-17

P-16

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE

TYP.

SEE P-104

FOR PIPE

CONT.

SEE P-104

FOR PIPE

CONT.

SEE P-104

FOR PIPE

CONT.

4 TYP.

VENT PIPE

BELOW SLAB

VENT PIPE

BELOW SLAB

4" VTR

2" IW 2" IW 2" IW 2" IW 2" IW 2" IW 2" IW 2" IW

4" V4" V

8"

IW

8"

IW

3" IW, REFER TO CIVIL DWGS FOR CONTINUATION

4" W, REFER TO CIVIL DWGS FOR CONTINUATION

8" IW, REFER TO CIVIL DWGS FOR CONTINUATION

2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE

DETAIL A3/P-506.

12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE

TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH

8" DIAMETER SIDE OUTLET CONNECTION

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-106

PL

U

M

BI

N G

S

AN

IT

AR

Y W

AS

TE

/V

EN

T

PL

AN

AR

EA

"E

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "E"

KEYNOTES

1. BUILDING FINISHED FLOOR ELEVATION NEAR THE HANGAR DOOR IS 823.60' PER THE CIVIL DRAWINGS.

2. NO UNDERFLOOR PIPING IN HANGAR BAY UNLESS OTHERWISE NOTED.

3. SLOPE TRENCH DRAIN IN THE DIRECTION OF THE SLOPE ARROWS BY 0.5%.

4. PIPING CONNECTED TO THE HANGAR TRENCH DRAINAGE SYSTEM SHALL BE CAST IRON PIPING FROM THE

TRENCH DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.

5. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.

6. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.

7. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.

8. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE

LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

9. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW

FOUNDATION FOOTINGS.

10. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

K

K

CR

DL

SB

SB

SB

SB

C R D

L

K

K

CR

DL

SB

SB

SB

SB

C R D

L

654321

0.9

C

A

1.9 2.9 3.9 4.4 5.6 6.6

CREW CHIEF

WORK ROOM

(COMPANY C)

CREW CHIEF

WORK ROOM

(COMPANY B)

CREW CHIEF

WORK ROOM

(COMPANY A)

FACILITY

STORAGE ROOM

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

RECYCLE ROOM

MEN'S

WOMEN'S

SPECIAL TOOLS

ROOM

ELECTRICAL

ROOM

COMMUNICATIONS

ROOM

PRODUCTION

CONTROL

ACN EQUIPMENT

JANITOR

129QUALITY

CONTROL

QUALITY

CONTROL OFFICE

PRODUCTION

CONTROL OFFICE

CORRIDOR 4

157D

CORRIDOR 2

157B

UNIT STORAGE

(COMPANY D)

146AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) STORAGE

AIRCRAFT

MAINTENANCE

BAY

AIRLOCK 1

157E

CORRIDOR 2

157B

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) SHOP

MATCHLINE A

SEE SHEET P-110

MATCHLINE A

SEE SHEET P-110

P-401 D5

1 1

3/4" CW

3/4" HW

GFGI WASHER

& DRYER

P-16

P-16

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

MULTI PURPOSE /

BREAK / CONF

ARMS VAULT

(COMPANY D)

CAGE

C155B

NBC STORAGE

C146B

P-13 P-9

P-14 P-9

P-17

OXYGEN

GENERATOR

P-11

P-12 P-15

1" HW

3/4" HWR

1 1/4" CW

1/

2" C

A

1 1/2" CW

3/4" HWR

1 1/4" HW

1 1/4" CW

3/4" HWR

3/4" HW

1 1/4" HW

3/4" HWR

1 1/2" CW

3/4" HW

3/4" CW P-19

P-10

P-13B

P-5

2" HW

3/4" HWR

2 1/2" CW

1 1/2" CA

1 1/4" CW

2 1/2" CA 2 1/2" CA

P-18

SEE P-110 FOR

PIPE CONT.

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

P-401 A1

P-401 A3

P-13B

PROVIDE TAIL PIECE

TRAP PRIMER FROM

P-13B TO P-19. SEE

DETAIL E5/P-504

PROVIDE TAIL

PIECE TRAP

PRIMER FROM

P-7 TO P-18.

SEE DETAIL

E5/P-504

P-18

P-18

TRAP PRIMER

TO P-18, SEE

DETAIL D8/P-504

TRAP PRIMER

TO P-18. SEE

DETAIL D8/P-504

A6 P-303

D1 P-303

GFGI OXYGEN GENERATOR

LADDER & HATCH.

COORDINATE REQUIRED

CLEARANCE BETWEEN

PIPES AND LADDER WITH

ARCHITECTRE.

P-18

LADDER & HATCH. SEE

ARCHITECTURE SHEETS

3 3

1 1/4" CW

1" CA

PROVIDE CLAMP-ON

ULTRASONIC ENERGY

FLOWMETER ON HOT

AND COLD WATER LINE

TO CLOTHES WASHER

P-7

HW, HWR, &

CW ISOLATION

VALVES (N.O.)

COMMUNICATIONS

STORAGE

C146A

NON-SENSITIVE

SECURE

STORAGE

146A

VESTIBULE

155A

CAGE

C149CAGE

C152

1" CA 1" CA

1 1/2" CA

1/

2" C

A

1 1/2" CA

1 1/2" CA

TRAP PRIMER TO

P-11 & P-18, SEE

DETAIL D8/P-504

3/4" CW

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

HW & CW

ISOLATION

VALVE (N.O.)

ROUTE CW PIPE BRANCH

TO P-16 BELOW WINDOW

CW & HW

ISOLATION VALVE

BELOW (N.O.)

1 1/2" CA

CW ISOLATION VALVE (N.O.)

CW ISOLATION VALVE

ON VERTICAL (N.O.)

A

CD

B E

1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE

STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE

PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.

COMPRESSED AIR DROP, SEE DETAILS

COMPRESSED AIR DROP WITH HOSE REEL, SEE

DETAILS

4" DCW, CONNECT TO CIVIL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-107

PL

U

M

BI

N G

D O

M

ES

TI

C

W

AT

ER

/C

O M

PR

ES

SE

D

A

IR

PL

AN

AR

EA

"A

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.

2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.

3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.

5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "A"

PF

PFPF

CR

K C

R

SB

SB

SB

SB

CR

K C

R

SB

SB

SB

SB

PF

PFPF

A

CD

B E

13.1

121110987

C.9

C

A

6.6 7.5 8.4 9.4 10.4 12.1

SPECIAL TOOLS

ROOM

ELECTRICAL

ROOM

REPAIR SECTION

WORKROOM

COMMUNICATIONS

ROOM

FIRE

PROTECTION

MECHANICAL

ROOM

AIRFRAME

REPAIR PLATOON

OFFICE

AIRFRAME

REPAIR PLATOON

COMPONENT

REPAIR PLATOON

OFFICE

COMPONENT

REPAIR PLATOON

AIRCRAFT

MAINTENANCE

BAY

AIRCRAFT

MOUNTED

WEAPONS VAULT

COMSEC SECURE

STORAGE

SYSTEMS REPAIR

SHOP

CONTRACTOR

LOGISTICS

SUPPORT

LOGISTICS

ASSISTANCE

REPRESENTATIVES

(LARS)

COMMUNICATIONS

ROOM

ELECTRICAL

ROOM

POWER PLANT/

POWERTRAIN

SHOP

STRUCTURAL

REPAIR SHOP

CORRIDOR 1

157A

1ST SERGEANT

OFFICE

COMMANDER

OFFICE

ORDERLY ROOM

(COMPANY D)

SHOP SECTION

HQ

PLATOON OFFICE

MECHANICAL

ROOM

COMPRESSOR

ROOM

BLADE REPAIR

SHOP

AIRLOCK 3

157G

CORRIDOR 2

157B

AIRLOCK 2

157F

CORRIDOR 2

157B

NONDESTRUCTIVE

INSPECTION (NDI)

ROOM

P-17

MATCHLINE A

SEE SHEET P-111

MATCHLINE A

SEE SHEET P-111

OVERHEAD CRANE IN

SHOP REFERENCE

STRUCTURAL DRAWINGS

FOR DETAILS.

P-402 B1

P-16

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

D2 P-301

2" HW

3/4" HWR

2 1/2" CW

1 1/2" CA

1 1/2" HW

3/4" HWR

1 1/2" CA

1 1/2" HW

3/4" HWR

P-14 P-14

P-18 P-9

P-14P-18 P-9

P-16

P-18

P-18

P-18

P-18

P-8

P-19 P-18

P-13A P-13A

P-19

P-19 P-10

1" CW

1 1/2" CA

3/4" CW

P-19 P-10

P-19 P-10

3/4" HWR 1 1/4" HW

1" CW

2 1/2" CA

1 1/4" CW

1" CA

3/4" HWR

1 1/4" CW

3/4" HWR

P-17

1/2" CW

1/2" CW

1/2" CW

1/2" CW

1/ 2"

C W

1/ 2"

C W

1/2" CW

2" HW

3/4" HWR

1 1/2" CA

2 1/2" CA

2 1/2" CA

A4 P-302

AUTOMATIC TRAP

PRIMER, SEE DETAIL

D1/P-504

AUTOMATIC TRAP

PRIMER, SEE

DETAIL D1/P-504

P-401 A5

P-401 A9

P-402 B7

1 1

P-401 A7

D7 P-301

DSH HWS & R SEE MECH

FOR CONTINUATION

SEE P-111

FOR PIPE

CONT.

SEE P-109 FOR

PIPE CONT.

SEE P-107

FOR PIPE

CONT.

AUTOMATIC TRAP PRIMER,

SEE DETAIL D1/P-502

P-17

TRAP PRIMER TO

P-18. SEE DETAIL

D8/P-504.

PROVIDE TAIL PIECE TRAP

PRIMER FROM P-13A TO

P-19. SEE DETAIL E5/P-504

A4 P-303

1/2" CW

1/ 2"

C W

2 1/2" CA

AUTOMATIC TRAP

PRIMER, SEE

DETAIL D1/P-504

ETP

ETP

ETP

SEE P-107

FOR PIPE

CONT.

2 1/2" CA

SEE P-109

FOR PIPE

CONT.

P-18

TRAP PRIMER TO

P-18. SEE DETAIL

D8/P-504.

P-9

1 1/4" HW

1/2" CW LINE

TO STAND

PIPE P-TRAP

1/2" CW LINE

TO STAND

PIPE P-TRAP

BELOW

1" HW

1" CW

BELOW

1 1/4" CW 1 1/4" HW

3/4" CW

1" CW3/4" CW

1 1/4" HW

1" CA

1" CA

1" CA

1" CA

1/2" CW

2 1/2" CA

1/

2" C

A

CAGE

C108A

CAGE

C106

CAGE

C108B

3/4" CW

1" CW

1 1/2" CA

CW ISOLATION VALVE BELOW (N.O.)

CW

ISOLATION

VALVE

BELOW

HW & CW

ISOLATION VALVES

ON VERTICAL

CHILLED WATER

MAKE UP

CONNECTION

CW ISOLATION

VALVE

CW ISOLATION

VALVE

CW

ISOLATION

VALVE

HW & CW

ISOLATION VALVES

ON VERTICAL

CA ISOLATION

VALVE (N.O)

CA ISOLATION VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O.)

CA ISOLATION

VALVE (N.O)

CA ISOLATION

VALVE (N.O.)

1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE

STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE

PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.

COMPRESSED AIR DROP, SEE DETAILS

COMPRESSED AIR DROP WITH HOSE REEL, SEE

DETAILS

4" DCW, CONNECT TO CIVIL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-108

PL

U

M

BI

N G

D O

M

ES

TI

C

W

AT

ER

/C

O M

PR

ES

SE

D

A

IR

PL

AN

AR

EA

"B

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1.

1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "B"

KEYNOTES

1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.

2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.

3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.

5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

PFPF

CD

B E

13.1

H

G

F

C.9

H.1

BLADE REPAIR

SHOP

PNEUDRALICS

REPAIR SHOP

CORRIDOR 3

157C

P-16

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

/ P -1

M

AT

C

H

LI

N E

C

SE

E

SH

EE

T

P-

/ P

-1

1" CW

D4 P-302

AIRCRAFT PARTS

SUPPLY OFFICE /

AIRCRAFT PARTS

SUPPLY / 102

P-109 E2

SEE P-108

FOR PIPE

CONT.

SEE P-111

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

1/2" CA

1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE

STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE

PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.

COMPRESSED AIR DROP, SEE DETAILS

COMPRESSED AIR DROP WITH HOSE REEL, SEE

DETAILS

4" DCW, CONNECT TO CIVIL

13.1

CORRIDOR 3

157C

PNEUDRALICS

REPAIR SHOP

P-10

1" CW

1" CW

3/4" HWR

3/4" HW

P-19 P-13A

PROVIDE TAIL PIECE TRAP

PRIMER FROM P-13A TO P-19.

SEE DETAIL E5/P-504

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-109

PL

U

M

BI

N G

D O

M

ES

TI

C

W

AT

ER

/C

O M

PR

ES

SE

D

A

IR

PL

AN

AR

EA

"C

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"A5

PLUMBING DOMESTIC WATER/COMPRESSED

AIR PLAN - AREA "C"

SHEET NOTES

KEY PLAN

KEYNOTES

1/4" = 1'-0"E2

PLUMBING DOMESTIC WATER/COMPRESSED

AIR PLAN - AREA "C" - 1

1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE

STOP SYSTEMS AT ALL PENETRATIONS BETWEEN

THE HANGAR AND SHOP DEMISING WALL.

2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF

NEAREST DRAIN VALVE.

3. COORDINATE WITH STRUCTURAL AT CONDITIONS

WHERE DOMESTIC WATER PIPES ARE LOCATED

BELOW SLAB AND PENTRATE THOUGH FOUNDATION

WALLS.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS

WHERE DOMESTIC WATER PIPES RUN BELOW

FOUNDATION FOOTINGS.

5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE

NOTE 30 ON SHEET P-001.

B E

7654321

0.9

K

J

H

G

F

P-16

AIRCRAFT

MAINTENANCE

BAY

MATCHLINE A

SEE SHEET P-107

MATCHLINE A

SEE SHEET P-107

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

P-9

P-18

P-17

1 1/4" CW

1" CA

1" CW

FLOOR MOUNTED

HOSE REELS (TYP)

1 1 1

1-1/2" CA UP 1-1/2" CA UP 1-1/2" CA UP

AUTOMATIC TRAP

PRIMER, SEE

DETAIL D1/P-504

ETP

SEE P-107

FOR PIPE

CONT.

SEE P-107

FOR PIPE

CONT.

SEE P-107

FOR PIPE

CONT.

SEE P-107

FOR PIPE

CONT.

1" CW

CRANE SYSTEM,

SEE STRUCTURAL.

FOAM

SUPPRESSION

SYSTEM, SEE FIRE

PROTECTION, TYP.

1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE

STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE

PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.

COMPRESSED AIR DROP, SEE DETAILS

COMPRESSED AIR DROP WITH HOSE REEL, SEE

DETAILS

4" DCW, CONNECT TO CIVIL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-110

PL

U

M

BI

N G

D O

M

ES

TI

C

W

AT

ER

/C

O M

PR

ES

SE

D

A

IR

PL

AN

AR

EA

"D

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "D"

KEYNOTES

1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.

2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.

3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.

5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

121110987

K

J

H

G

F

H.1

MATCHLINE A

SEE SHEET P-108

MATCHLINE A

SEE SHEET P-108

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E C

SE

E

SH

EE

T P-

P-13

P-9 P-18

1" CA

1 1/4" HW

3/4" HWR

FLOOR MOUNTED

HOSE REEL (TYP)

D4 P-302

1-1/2" CA UP

1 1

1-1/2" CA UP 1-1/2" CA UP

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

M

AT

C H

LI

N

E B

SE

E

SH

EE

T P-

P-17 P-16

AIRCRAFT

MAINTENANCE

BAY

PROVIDE TAIL

PIECE TRAP

PRIMER FROM

P-13 TO P-18. SEE

DETAIL E5/P-504.

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

CA ISOLATION VALVE

ON VERTICAL (N.O.)

A

CD

B E

1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE

STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE

PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.

COMPRESSED AIR DROP, SEE DETAILS

COMPRESSED AIR DROP WITH HOSE REEL, SEE

DETAILS

4" DCW, CONNECT TO CIVIL

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-111

PL

U

M

BI

N G

D O

M

ES

TI

C

W

AT

ER

/C

O M

PR

ES

SE

D

A

IR

PL

AN

AR

EA

"E

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

KEY PLANSHEET NOTES

04' 8' 16'2'6'8'

SCALE: 1/8"=1'-0"

PLAN NORTH

1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "E"

KEYNOTES

1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.

2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.

3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.

4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.

5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.

121110987654321

0.9

K

J

H

G

F

C.9

C

A

1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1

H.1

6"x6" MA INTAKE

12"x12" MA INTAKE

18"x16" OA INTAKE 10"x10" MA INTAKE 16"x16" OA INTAKE

12"x12" EA OUTLET

6"x6" EA OUTLET

14"x14" MA INTAKE

10"x10" MA INTAKE

24"x24" EA DUCT

UP TO EF-105

6"x6" EA OUTLET

20"x20" EA OUTLET

18"x18" MA INTAKE

8"x8" EA OUTLET

18"x18" MA INTAKE

16"x16" EA OUTLET

14"x14" MA INTAKE

4" VTR

2" VTR

2" VTR

2" VTR

2" VTR

2" VTR

2" VTR

6"x6" EA OUTLET

ROOF HATCH, SEE

ARCHITECTURE

10"x10" EA OUTLET

40"x20" EA OUTLET

4" VTR

2" VTR

2" VTR

1 1/2" VTR

2" VTR

4" VTR 4" VTR

EF

EF

12"x12" EA DUCT

UP TO EF-155

WALKING PADS, SEE

ARCHITECTURE TYP.

ROOF HATCH, SEE

ARCHITECTURE

12"x12" EA OUTLET

A

CD

B E

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-112

PL

U

M

BI

N G

R O

O F

PL

AN

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/16" = 1'-0"B4 PLUMBING ROOF PLAN

PLAN NORTH

08' 16' 32'4'12'16'

SCALE: 1/16"=1'-0"

1. COORDINATE ALL ROOF PENETRATIONS WITH ARCHITECTURAL AND STRUCTURAL

KEY PLANGENERAL NOTES KEYNOTES

01_FINISH FLOOR

0' - 0"

A

HWST

EHWH

EHWH

ET

STRAINER

1 1/2" CA

GATE VALVE

GATE VALVE

WATER METER

SYSTEM DRAIN

2" HW

2" HWR

BMV-1

HIGH-LOW THERMOSTATIC

MIXING VALVE

CORRIDOR 2

157B

MECHANICAL

ROOM

HWR BALANCING VALVE,

BALANCE TO 3.0 GPM

HWRP

2 1/2" CW

2 1/2" HW

1" HWR

8"x8"

SEE CIVIL FOR PIPE CONT.

TBP

ETP

AUTOMATIC TRAP

PRIMER, SEE

DETAIL D1/P-504

2" HW 2 1/2" CW

1" CW

2" HW

P-19

2" HWR 2" HW BEHIND

1 1/2" HW

1" HWR

3" CW

1" HWR

1 1/2" HW2" CW

2" CW

1" HW

1/2" CW

2 1/2" HW2" HW1 1/2" HW1 1/2" HW

4" CW

3" CW

4" CW

10"x18"

2 1/2" CW3/4" CW

01_FINISH FLOOR

0' - 0"

C

CABLE TRAY,

SEE ELECTRICAL

LOCATE PIPES PARALLEL WITH THE

CABLE TRAY AND ON THE OPPOSITE

WALL IN COORDIDORS.

WHERE PIPES CROSS OVER CABLE TRAY,

PROVIDE A MINIMUM 12" CLEARANCE

BETWEEN TOP OF CABLE TRAY AND

BOTTOM OF PIPES.

CORRIDOR 2

157B

20"x18" 20"x20"

1 1/2" CA

2 1/2" CW

2" HW

3/4" HWR

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-301

PL

U

M

BI

N G

B U

IL

D

IN

G

S

EC

TI

O

N

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

3/8" = 1'-0"D2 MECH ROOM DOMESTIC WATER SECTION

3/8" = 1'-0"D7 SECTION AT CORRIDOR 2 157B

02' 4'1'3'4'

SCALE: 3/8"=1'-0"

02_BO_ADMIN

ROOF STRUCT

18' - 0"

03_TO_PARAPET_ADMIN

ROOF

19' - 4"

121110.4 12.1

P-19

3/4" HWR1 1/4" HW

2" IW

P-13A

CA DROP "TYPE A",

SEE SHEET A1/P907

3/4" HW

2" IW

POWER PLANT/

POWERTRAIN

SHOP

AIRLOCK 3

157G

COMSEC SECURE

STORAGE

STRUCTURAL

REPAIR SHOP

12"x12"

"x

1 1/2" CW

P-9

2" V

BEHIND BEHIND

2" V

3/4" HW

1" CD

3/4" CW2" V

1 1/4" CW

1 1/4" HW

2" V

1" C

A

1" C

A

1" C

A

1" CA

01_FINISH FLOOR

0' - 0"

02_BO_ADMIN

ROOF STRUCT

18' - 0"

03_TO_PARAPET_ADMIN

ROOF

19' - 4"

H G FH.1

P-13 P-9

P-18

1/2" CA

3/4" HW

3/4" CW

2" V

2" IW 2" IW

CA DROP "TYPE A",

SEE SHEET A1/P907

CA DROP "TYPE A",

SEE SHEET A1/P907

3/4" HW

AIRCRAFT

MAINTENANCE

BAY

BLADE REPAIR

SHOP

1/2" CA

2" V

1" CW

P-17

1" CW

3/4" HWR

1" CA

1 1/4" HW 3/4" HWR 1 1/4" CW

BEHIND BEHIND BEHIND

FOAM TANK CONTAINMENT

SYSTEM MONITORING

PANEL , SEE MECHANICAL

1 1/4" CW

1/2" CA

1" CA

1" CW

2" V

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-302

PL

U

M

BI

N G

B U

IL

D

IN

G

S

EC

TI

O

N

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/4" = 1'-0"A4 SECTION VIEW - GRIDLINE 'F' (10.4 - 12.1)

1/4" = 1'-0"D4 SECTION VIEW - GRIDLINE '13' (F - H.1)

02_BO_ADMIN

ROOF STRUCT

18' - 0"

03_TO_PARAPET_ADMIN

ROOF

19' - 4"

5 4.45.6

P-9

P-18

P-14

2 1/2" CA 2 1/2" CA

26"x26"32"x20" 20"x20"

"x

1 1/4" CW

1" CA

EF

AIRCRAFT

MAINTENANCE

BAY

P-17

01_FINISH FLOOR

0' - 0"

02_BO_ADMIN

ROOF STRUCT

18' - 0"

03_TO_PARAPET_ADMIN

ROOF

19' - 4"

10 9 8 7.58.49.410.4

AIRCRAFT

MAINTENANCE

BAY

26"x26"

12"x12"

32"x20"

"x

20"x20"

"x

P-14

P-9

P-18

P-14

TRAP PRIMER, SEE

DETAIL A8/P-5031 1/4" CW

3/4" CW

1" CA

EF

100B EF

P-17

2 1/2" CA 2 1/2" CA2 1/2" CA

2" V

1" CW 1" HW

1 1/2" V

2" IW

2" IW

2" IW

1 1/2" V 1" HW

1" CW

1 1/4" HW 1 1/4" CW 1" HW

01_FINISH FLOOR

0' - 0"

02_BO_ADMIN

ROOF STRUCT

18' - 0"

03_TO_PARAPET_ADMIN

ROOF

19' - 4"

3 22.9

2" V

1 1/4" CW

1/2" CW

3/4" HW

2" V

3/4" CW

TRAP PRIMER, SEE

DETAIL A8/P-503

2" IWP-18

P-9

P-13

AIRCRAFT

MAINTENANCE

BAY

2 1/2" CA

20"x20"

"x

32"x20"

"x

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-303

PL

U

M

BI

N G

B U

IL

D

IN

G

S

EC

TI

O

N

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/4" = 1'-0"A6 SECTION VIEW - GRIDLINE 'C' (4.4 - 5.6)

1/4" = 1'-0"A4 SECTION VIEW - GRIDLINE 'C' (7.5 - 10.4)

1/4" = 1'-0"D1 SECTION VIEW - GRIDLINE 'C' (2 - 3)

JJD

D

D

D

54.4 5.6

P-18

P-2 P-2 P-4A P-4 P-4

P-18

P-18

P-4 P-4 P-4 P-4

P-1AP-1P-1P-1P-1

P-1 P-1 P-1 P-1A

P-4A

P-4

P-4

P-18A

P-18

P-6

P-3 P-3

1 1/2" HW1 1/2" CW

3/4" HW

MEN'S

WOMEN'S

MOTHER'S ROOM

AUTOMATIC TRAP

PRIMER. SEE

DETAIL D1/P-504

ETP-126 ISOLATION VALVE

AUTOMATIC TRAP

PRIMER. SEE

DETAIL D1/P-504

1/2" CW 1/2" CW

DCW WATER

HAMMER

ARRESTOR,

PDI SIZE C

DCW WATER HAMMER

ARRESTOR, PDI SIZE B

ETP

ETP

P-12 P-12

HWR BALANCING

VALVE. BALANCE

TO 0.5 GPM

SEE P-107

FOR PIPE

CONT.

SEE P-107

FOR PIPE

CONT.

SEE P-107

FOR PIPE

CONT.

P-18A P-18A P-18A

P-18AP-18AP-18AP-18A

P-18A

P-18A

P-8

SEE P-107

FOR PIPE

CONT.

1 1/4" HW

3/4" HWR

2 1/2" CW

1 1/4" HW

2 1/2" CW

1/2" HW

1/2" CW1/2" CW

SEE P-107

FOR PIPE

CONT.

DCW HAMMER

ARRESTOR, PDI SIZE C

DCW HAMMER

ARRESTOR,

PDI SIZE B

DCW HAMMER

ARRESTOR, PDI SIZE D

P-3 P-3 P-3

3/4" HW 3/4" CW

1/2" CW

ETP-127 ISOLATION VALVE

HW ISOLATION

VALVE (N.O.)

CW ISOLATION

VALVE (N.O.)

1" HW

1" CW

1/2" CW

HW, CW, HWR,

ISOLATION

VALVE (N.O.)

1 1/4" HW

3/4" HWR

1 1/2" CW

1 1/2" CW

2" HW

3/4" HWR

2 1/2" CW

54.4 5.6

P-18

P-18

P-6

P-4AP-2

P-2

P-4 P-4

P-18

3" IW

P-1 P-1 P-1 P-1 P-1A

MEN'S

WOMEN'S

P-1 P-1 P-1 P-1A

P-3 P-3

P-4 P-4 P-4 P-4

P-4A

P-4

P-4

MOTHER'S ROOM

2" WCO

SEE P-102

FOR PIPE

CONT.

SEE P-102

FOR PIPE

CONT.

SEE P-102

FOR PIPE

CONT.

SEE P-102

FOR PIPE

CONT.

SEE P-102

FOR PIPE

CONT.

P-18A P-18A P-18A

P-18A P-18A P-18A P-18A

P-18

P-18A

P-18A

P-18A

P-8

P-12 P-12

P-3 P-3 P-3

2" FCO

4" VTR

3" IW

4" V

2"

IW

2" V

2" V

3" FCO

4" FCO

2" W

2" W

2" IW

2" W

4" FCO

SEE P-102

FOR PIPE

CONT.

SEE P-102

FOR PIPE

CONT.

2" FCO

4" W

2" W2" W 2" W

4" W

3" W 4" W

2" W

2" W

2" W

2" W

3" W 2" W

4" W

3" W

2" W 2" W

2" W 2" W 2" W 2" W

2" W

4" W

3" W 3" W 3" W 3" W 3" W

3" W 3" W 3" W 3" W

3" W

3" W

3" V

2" V

2" V

2" V

3" V

2" V

2" W

CORRIDOR 2

157B

AVIATION LIFE

SUPPORT

EQUIPMENT

(ALSE) SHOP

1" HW

3/4" HWR

1 1/4" CW

1 1/4" HW

3/4" HWR

1 1/2" CW

HWR BALANCING

VALVE, BALANCE

TO 0.5 GPM

HWR BALANCING VALVE,

BALANCE TO 0.5 GPM

ISOLATION

VALVE (TYP)

1 1/4" CW

3/4" HWR

3/4" HW

1 1/2" CA

1" C

A

5.6

3/ 4"

H W

R 2"

H W

1 1/4" HW

3/4" HWR

2 1/2" CW

1 1/2" CA

2" HW

3/4" HWR

HWR BALANCING VALVE,

BALANCE TO 0.5 GPM

MOTHER'S ROOM

CORRIDOR 2

157B

1/

2" C

W

ISOLATION VALVE

(TYP) 2" HW

3/4" HWR

1 1/2" CA

1 1/2" HW

2" CW

1 1/2" CA

HWR BALANCING

VALVE, BALANCE

TO 1.5 GPM

HWR BALANCING

VALVE, BALANCE

TO 1.5 GPM

FIRE

PROTECTION

MECHANICAL

ROOM

CORRIDOR 2

157B ISOLATION

VALVE (TYP)

HWRP

2 1/2" CW

3/4" CW ETP

1" HWR

3/4" HWR

13.1

3/4" HWR

1 1/2" CW

HWR BALANCING

VALVE. BALANCE

TO 0.5 GPM

HWR BALANCING

VALVE. BALANCE

TO 0.5 GPM

AIRCRAFT

MAINTENANCE

BAY

PNEUDRALICS

REPAIR SHOP

BLADE REPAIR

SHOP

HWR BALANCING

VALVE. BALANCE

TO 1 GPM

1 1/4" HW

1" CA ISOLATION

VALVE (TYP)

CABLE TRAY BELOW PIPES.

PROVIDE MIN CLEARANCE OF

1'-0" BETWEEN BOTTOM OF

PIPE AND TOP OF CABLE TRAY

3/4" HW

3/4" HWR

1" CW

1/

4" H

W

3/ 4"

H W

R

1/

4" C

W

10.4

HWR BALANCING

VALVE. BALANCE

TO 0.5 GPM

AIRCRAFT

MAINTENANCE

BAY

COMSEC SECURE

STORAGE

AIRLOCK 3

157G

HWR BALANCING VALVE.

BALANCE TO 1 GPM

1 1/4" HW

3/4" HWR

ISOLATION

VALVE (TYP)

1 1/2" CW

1 1/2" HW

3/4" HWR 2" CW

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-401

PL

U

M

BI

N G

E N

LA

R

G

ED

P

LA

N S

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

H

AN

G

AR

1/4" = 1'-0"D5 ENLARGED DOMESTIC WATER RESTROOM PLAN

1/4" = 1'-0"D1 ENLARGED SANITARY WASTE/VENT RESTROOM PLAN

1/2" = 1'-0"A1 ENLARGED PLAN VIEW 1

1/2" = 1'-0"A3 ENLARGED PLAN VIEW 2

1/2" = 1'-0"A5 ENLARGED PLAN VIEW 3

1/2" = 1'-0"A9 ENLARGED PLAN VIEW 5

1/2" = 1'-0"A7 ENLARGED PLAN VIEW 4

01' 3'2'3'

SCALE: 1/2"=1'-0"

8.4

D2 P-301

BUILDING WATER

METER (M-1), SEE

SPEC 22.00.00 FOR

REQIREMENTS

ET

P-18

P-18

P-19

1 1/2" HW

1/2" CW

1/2" CW

P-17

HWP

HWP

BMV-1

1 1/2" HW

3/4" HWR

1 1/2" CA

2 1/2" HW

EHWH

EHWH

HWST

1" HWR

3" CW

2" HWR

2" HW

2" HW

4" CW

MECHANICAL

ROOM

AUTOMATIC TRAP

PRIMER SEE DETAIL

D1/P-504

HWRP

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

DSH HWS & R

SEE MECH FOR

CONTINUATION

HWR BALANCING VALVE,

BALANCE TO 1.5 GPM

ETP

SEE CIVIL FOR

PIPE CONT.

PROVIDE CLAMP-ON

ULTRASONIC ENERGY

FLOWMETER ON HW

SUPPLY LINE (SM-2)

FROM EHWH-1 AND

EHWH-2.

TBP

P-19

3" CW

2 1/2" CW 1" HWR2 1/2" HW

2" CW

CW ISOLATION VALVE

2" HWR

2" HW

1 1/2" HW

1 1/2" HW

2" CW

1/2" CW

1/2" CW

2" CW

2 1/2" CW

1 1/2" HW

3/4" HWR

13.1

A

P-16

P-17

SEE P-108

FOR PIPE

CONT.

SEE P-108

FOR PIPE

CONT.

COALESCING FILTER

AUTOMATIC TRAP

PRIMER. SEE DETAIL

D1/P-504

PARTICULATE FILTER

ETP

COMPRESSOR

ROOM

P-19

P-18

P-19

ART

AD

AC

AC

3/ 4"

C W

1/

2" C

A

1" C

W

1" C

D

ISOLATION VALVE (TYP)

PRESSURE GUAGE

1/ 2"

C W2

1/ 2"

C A

2 1/2" CA

1" CD

1" CD

1" CD

3/ 4"

C W

2" CA

2 1/2" CA

CONDENSATE FROM

AD-1 TO P-19 ID

CONDENSATE FROM

ART-1 TO P-19 ID

ALL CONDENSATE FROM AC-2 & AC-1 TO P-19 ID

1/ 2"

C W

FLEXIBLE CONNECTOR, TYP.

PRESSURE REGULATOR

(SET TO 110 PSI)

SEE P-108

FOR PIPE

CONT.

1/2" CW

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

D

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

P-402

PL

U

M

BI

N G

E N

LA

R

G

ED

P

LA

N S

H O

N O

LU

LU

D

IS

TR

IC

T

FT

. S H

AF

TE

R , H

AW

AI

I 9

R

EG

IO

N

AL

E

N G

IN

EE

R

IN

G C

EN

TE

R H

O N

O

LU

LU

D

IS

TR

IC

T

H O

N O

LU

LU

, H I

TS

, D

N

TS KAKM

J

AN

FI

LE

N U

M

BE

R

FI

LE

N

AM

E:

DESIGN COMPLETE REV 12 JAN 2021

W H

EE

LE

R A

R M

Y

AI

R

FI

EL

D

, O

AH

U , H

AW

AI

I

FY

M

C A

PN

AI

R

C R

AF

T

M

AI

N

TE

N

AN

C E

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .