FILE 12 OF 15 06 Plumb Design Complete REV 01-12-2021.pdf
PDF 9 MB Posted
- Solicitation number
- W9128A21R0004
About this file
This announcement is a solicitation for a construction contract. The U.S. Army Corps of Engineers is seeking proposals to construct a modified standard design rotary wing aircraft maintenance hangar at Wheeler Army Airfield in Oahu, Hawaii. The project scope includes the hangar, maintenance shops, administrative space, parts and tool storage, hazardous materials storage, petroleum storage, ground support equipment storage, covered storage, hangar access apron, aircraft washing apron, fire pump building, special foundations, cybersecurity measures, building systems, fire protection, intrusion detection, and utility monitoring. Supporting facilities comprise site development, utilities, separate water storage, lighting, paving, parking, drainage, landscaping, and signage. Air conditioning will be provided by self-contained units. Access for individuals with disabilities and sustainability measures are required. The project magnitude is $50-100 million. Proposals will be evaluated on experience, past performance, organization, small business participation plan, and price using best value tradeoff procedures. The contract award is fixed price.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PLUMBING LEGEND
SYMBOL ABBRV. DESCRIPTION
U/G UNDERGROUND
BALANCING VALVE
CD CONDENSATE DRAIN
CO CLEANOUT
SS SANITARY SEWER
V VENT
WCO WALL CLEANOUT
T/P T/P RELIEF VALVE
UNION, THREADED
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
SS
SD STORM DRAIN
SP SUMP PUMP
RD ROOF DRAIN
AAV AUTOMATIC AIR VENT
A AMPS
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
ADJ ADJACENT
AFG ABOVE FINISHED GRADE
APPROX APPROXIMATE
ASSY ASSEMBLY
AV AIR VENT
ABV ABOVE
AI ANALOG INPUT
AO ANALOG OUTPUT
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BLDG BUILDING
BLW BELOW
BOT BOTTOM
BTWN BETWEEN
BV BALL VALVE
BYP BY PASS
BI BINARY INPUT
BO BINARY OUTPUT
SYMBOL ABBRV. DESCRIPTION
CHKV CHECK VALVE
CLG CEILING
CONT CONTINUATION
CONC CONCRETE
CW COLD WATER
DN DOWN
DEG DEGREE
DEMO DEMOLITION
DET DETAIL
DIA, Ø DIAMETER
ELEV ELEVATOR
EFF EFFICIENCY
EQUIP EQUIPMENT
EQUIV EQUIVALENT
EXST EXISTING
CD
BFP
AV
MAX
FD FLOOR DRAIN
°F FAHRENHEIT
FF FINISH FLOOR
FLA FULL LOAD AMPS
FLR FLOOR
FT FEET
FT WG FEET OF WATER GAUGE
GALVANIZEDGALV
GA GAUGE
GAL GALLON
GLOBE VALVEGLV
GOVERNMENTGOVT
GALLONS PER MINUTEGPM
GATE VALVEGTV
HAND-OFF-AUTOHOA
HORSEPOWERHP
HEIGHTHT
HOT WATER SUPPLYHW
HERTZHZ
HOURHR
INDIRECT DRAINID
INCHES OF WATER GAUGEIN WG
INVERTINV
ISOMETRICISO
KILOWATTKW
POUNDSLBS
LEAVINGLVG
LEAVING WATER TEMPERATURELWT
MAXIMUMMAX
THOUSAND BTUHMBH
MINIMUM CIRCUIT AMPSMCA
MECHANICALMECH
WATER METERM
MINUTE; MINIMUMMIN
NORMALLY CLOSEDNC
NOT IN CONTRACTNIC
NORMALLY OPEN; NUMBERNO
NOT TO SCALENTS
ON CENTERO.C.
OCCUPANCY SENSOROCC
OUTSIDE DIAMETEROD
PRESSURE DROPPD
PHASEPH
PRV
QTY
PRESSURE RELIEF VALVE
QUANTITY
ROOMRM
RATED LOAD AMPSRLA
REQUIREDREQ'D
PSI POUNDS PER SQUARE INCH
M
FCO FLOOR CLEANOUT
COTG CLEANOUT TO GRADE
HOSE BIBB / WALL HYDRANTHB
SHUT OFF VALVESOV
STANDARDSTD
SCHEDULESCH.
SYSTEMSYS
SIMILARSIM
SPECIFICATIONSPEC
THERMOMETER
TEMPERATURETEMP
TO FLOOR ABOVETFA
TO FLOOR BELOWTFB
TOP OF FINISH FLOORTFF
THICKTHK
THROUGHTHRU
TEMPERATURE SENSORTS
TYPICALTYP
VOLTV
VERTICALVERT
WATTW
WITHW/
WITHOUTW/O
WATER HEATERWH
WORKING PRESSUREWPR
WEIGHTWT
WATER HAMMER ARRESTORWHAWHA
NEW WORK
HOT WATER RETURNHWR
STRAINER, INLINE
T
UNION, FLANGED
PRESSURE GAUGE AND COCK
PIPE INTO PLANE, DOWN
PIPE OUT OF PLANE, UP
PIPE DIRECTION CHANGE
PIPE BRANCH, OUT OF PLANE
PIPE BRANCH, INTO PLANE
PIPE BRANCH IN PLANE
INDUSTRIAL WASTEIW INDUSTRIAL WASTEIW
GOVT FURNISHED GOVT INSTALLEDGFGI
SYMBOL
VENT TO ROOFVTR
ABBRV. DESCRIPTION
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-001
PL
U
M
BI
N G
A
BB
R
EV
IA
TI
O N
S, L
EG
EN
D , A
N D
G
EN
ER
AL
N O
TE
S
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
PLUMBING GENERAL NOTES
1. THE ENTIRE INSTALLATION SHALL COMPLY WITH INTERNATIONAL PLUMBING CODE (IPC) UNIFIED FACILITIES CRITERIA (UFC)
AND REQUIREMENTS LISTED IN CONTRACT DOCUMENTS.
2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER THE COMPLETE INSTALLATION OF SYSTEMS TO FUNCTION AS
DESCRIBED AND SPECIFIED. THE OMISSION OF REFERENCE TO ANY NECESSARY ITEM OF LABOR OR MATERIAL SHALL NOT
RELIEVE THE CONTRACTOR FROM PROVIDING SUCH LABOR AND MATERIAL.
2. PRIOR TO BIDDING, CONTRACTOR SHALL PARTICIPATE IN A SITE-INSPECTION TO GAIN A FAMILIARITY WITH THE LEVEL OF
DIFFICULTY INVOLVED WITH THIS PROJECT.
3. ALL EQUIPMENT SHALL BE CAPABLE OF FITTING INTO THE SPACES ALLOCATED WHILE MEETING THE MANUFACTUER'S RECOMMENDED ACCESS REQUIREMENTS. REVIEW ALL SPACES WHERE EQUIPMENT IS TO BE INSTALLED PRIOR TO ORDERING OF EQUIPMENT AND NOTIFY THE ENGINEER OF ANY INADEQUATE CLEARANCES OR CONDITIONS THAT WILL PREVENT THE
PROPER INSTALLATION, MAINTENANCE, AND OPERATION OF EQUIPMENT.
4. COORDINATE WITH OTHER TRADES PRIOR TO COMMENCING WORK AND DURING CONSTRUCTION. OVERLAY PLANS AND CHECK
FOR ANY DISCREPANCIES OR CONFLICTS WITH OTHER TRADES.
4. NO ASBESTOS OR LEAD CONTAINING MATERIALS SHALL BE USED IN THIS PROJECT.
4. COORDINATE EXACT LOCATION OF ROOF PENETRATIONS WITH ROOF STRUCTURE. ALL PENETRATIONS TO BE A MIN. 1'-6"
FROM WALLS, CURBS, PIPES, VENT STACKS, AND OTHER ROOF PENETRATIONS.
5. VERIFY AND COORDINATE ALL WALL AND FLOOR PENETRATIONS WITH THE STRUCTURAL AND ARCHITECTURAL DRAWINGS
PRIOR TO THE START OF CONSTRUCTION.
6. OBTAIN APPROVAL FROM THE STRUCTURAL ENGINEER BEFORE MAKING ANY PENETRATIONS THROUGH STRUCTURAL
MEMBERS, WALLS, AND SLABS.
7. SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK, MARK SUCH CHANGES ON THE AS-BUILT DRAWINGS. IF
THESE CHANGES REQUIRE ALTERNATE METHODS TO THOSE APPROVED BY THE CONTRACT DOCUMENTS, SUBMIT A RFI SHOWING THE PROPOSED ALTERNATE METHODS TO THE GOVERNMENT FOR REVIEW. DO NOT PROCEED UNTIL REVIEWED.
8. LOCATE ALL UTILITY LINES OR OTHER INTERFERENCES IN AREAS OF PROPOSED TRENCH WORK PRIOR TO START OF
EXCAVATION. REPAIR OR PAY FOR ALL DAMAGES TO EXISTING UTILITIES.
9. DRAWINGS DO NOT ATTEMPT TO SHOW EXACT DETAILS OF PIPING. PROVIDE OFFSETS AS NECESSARY TO AVOID LOCAL OBSTRUCTIONS OR INTERFERENCE WITH OTHER TRADES. REVIEW ALL PIPING RUNS PRIOR TO INSTALLATION AND IMMEDIATELY NOTIFY THE GENERAL CONTRACTOR OF ANY INTERFERENCE AND/OR LACK OF ADEQUATE CLEARANCES.
10. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR AND PROVIDE ALL CAULKING AND SEALANT REQUIRED TO COMPLETE THE INSTALLATION OF ALL PLUMBING FIXTURES AND FITTINGS. SEE CAULKING AND SEALANT SPECIFICATIONS IN CONTRACT
SPECS FOR APPROPRIATE CAULKING AND SEALANT SPECIFICATIONS.
12. PAINT ALL EXPOSED PIPING TO MATCH THE ADJACENT SURFACE.
14. PROPERLY FIRESTOP ALL PENETRATIONS THROUGH FIRE RATED WALLS, FLOORS, OR PARTITIONS WITH A UL APPROVED
SYSTEM APPROPRIATE FOR THE PENETRATION TYPE, FIRE RATING, AND AS SPECIFIED.
15. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, WATER HAMMERS, AND EQUIPMENT. PANELS SHALL BE AS
SPECIFIED. SIZES WILL BE DETERMINED BY SUBCONTRACTORS AS TO WHAT IS NEEDED TO SERVICE OR ACCESS. COORDINATE THE LOCATION OF ACCESS PANELS TO ENSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY. ACCESS PANELS SHOULD BE LOCATED IN CLOSETS, STORAGE AREAS, OR INCONSPICUOUS SPACES TO BE REVIEWED BY THE GENERAL CONTRACTOR ON FINAL LOCATION AND SIZES. THE ACCESS PANELS SHALL MATCH THE FIRE RATING FOR THE WALLS OR
CEILINGS THAT THEY ARE PENETRATING.
16. PROVIDE ISOLATION VALVES ON PIPING BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT. SHOW ALL ISOLATION
VALVES ON THE AS-BUILT DRAWINGS.
17. INSULATE ALL SEWER PIPING RECEIVING AIR CONDITIONING CONDENSATE DRAINS, ICE MACHINE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION FROM POINT OF CONNECTION TO THE TOP OF CONCRETE SLAB-ON GRADE.
INSULATE FLOOR DRAIN AND FLOOR SINK BODIES EXPOSED TO AIR BELOW THE FLOOR.
19 SEE ISOMETRIC DRAWINGS FOR DETAILED WATER, SEWER AND VENT PIPE SIZING.
20 SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND INSTALLATION OF PLUMBING FIXTURES AND EXACT BUILDING
DIMENSIONS.
21 CONTRACTOR TO COORDINATE AND VERIFY SERVICE CONNECTIONS ON ALL FIXTURES.
22 MANIFOLD ALL PLUMBING VENTS ABOVE FLOOD RIM LEVEL OF PLUMBING FIXTURES.
23 ALL WATER RUNS ARE OVERHEAD AND SHALL BE CONCEALED WHERE EVER POSSIBLE. ANY EXPOSED PIPING SHALL BE RUN
AS HIGH AS POSSIBLE AND RUN PARALLEL OR PERPENDICULAR TO BEAMS. SLOPE PIPES TO DRAIN.
24 MECHANICAL WATER HAMMER ARRESTORS SHALL BE LOCATED AS INDICATED ON THE PLAN DRAWINGS AND IN ACCORDANCE
WITH STANDARD PDI-WH201.
25 ALL IN-LINE AND ENDPOINT DEVICES SHALL MEET THE REQUIREMENTS OF NSF 61, SECTIONS 8 AND 9, RESPECTIVELY.
26 ALL VALVES SHALL BE LINE SIZE, UNLESS INDICATED OTHERWISE.
27 THE MAINTENANCE BAYS (RM 131 & RM 132) AND ALL ADJACENT ROOMS THAT OPEN DIRECTLY INTO IT SHALL BE CONSIDERED
CLASS I, DIVISION II HAZARDOUS AREAS UP TO 1'-6" AFF. THE CONTRACTOR SHALL INSTALL ALL ELECTRICAL EQUIPMENT AND
DEVICES A MINIMUM OF 1'-8" AFF UNLESS OTHERWISE INDICATED.
28 CONTRACTOR SHALL COORDINATE ALL GFGI EQUIPMENT WITH USER.
29 WHERE PIPES CROSS OVER CABLE TRAY, PROVIDE A MINIMUM 12" CLEARANCE BETWEEN TOP OF CABLE TRAY AND BOTTOM
OF PIPES.
30 PROVIDE PIPE EXPANSION JOINT CONNECTIONS AS REQUIRED TO ACCOMMODATE MOVEMENT FROM THE BUILDING’S
ISOLATION JOINTS. COORDINATE REQUIRED LOCATIONS WITH ARCHITECTURE AND STRUCTURAL. FOR ISOLATION JOINT LOCATIONS BETWEEN HANGAR MAINTENANCE BAY AND HANGAR ADMINISTRATION WING CMU WALLS, SEE SHEETS S-203 THROUGH S-206 OF STRUCTURAL DRAWINGS. INSTALL EXPANSION JOINTS PER MANUFACTURE’S RECOMMENDATION.
ES
ES
ES
ES
ES
ES
C O
M M
COMM
2.5'
3.0'
13.7'
3.0
3.0
3.0'W
F20
W
W6
W8
F24 SU
C
TIO
N
F16
F24
W
W
W6
F24 W2
W
W 1-1/2
H B
W8 W
W4
W6
F24 F24
W
W8
W
F24 FIR
E LO
O P
F24 F24 F24
HB
W1
W1
HB
W
W8
W8
W 3/4
F8
F6
HB
W1 F24
W
W
W6 F12
F12
F24
W3/4
W3/4
W3/4
W3/4
W3/4
W3/4
W8
FFE=823.68
CARPOOL ONLYCARPOOL ONLY CARPOOL ONLYCARPOOL ONLYCARPOOL ONLY CARPOOL ONLYCARPOOL ONLYCARPOOL ONLYCARPOOL ONLY
MOTORCYCLE
PARKING
D6 D15D15D15
D6
D
D18
D
D15
D24 D
D6
D4 D4
D18
D15
D15
D18 D18
D
D18
D
D18
D
D15
D6
D6
D6
D6
D6 D6 D6
D
D18
D15
D18D15 D6
33" MIN
30" MIN
87" MIN
PF
PFPFPF PF
PF
PF
PF
PFPFPF PF
PF
PF
BF
P
WASH RACKS
CHILLER ENCLOSURE
AMELIA EARHART ROAD
LA
U
H
AL
A R
O
AD
HAZARDOUS MATERIAL STORAGE AND POL STORAGE
PRE-FABRICATED STRUCTURES. SEE SPECIFICATIONS
FOR DETAILS
FUEL OIL STORAGE TANKS,
SEE SHEET M-505
OIL / WATER SEPERATOR,
SEE SHEET P-508
13.1
12111098765432
0.9
K
J
H
G
F
C.9
C
A
1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1
H.1
MATCHLINE A MATCHLINE A
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E B
M
AT
C H
LI
N
E B
P-101 A3
AIRCRAFT MAINTENANCE
HANGAR
G1 G2
GE
GD
GC
GB
GA
GSE/ASIOE
COVERED
STORAGE
BUILDING
P-403 A1
FA
FB
F1 F2FIRE PUMP
BUILDING
P-404 B1
WA
WB
WC
W1 W2
WATER STORAGE
TANK
P-405 D1
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-002
PL
U
M
BI
N G
O
VE
R
AL
L
SI
TE
P
LA
N
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
PLAN NORTH
0 40'20' 80'
SCALE: 1" = 40'-0"
1" = 40'-0"A4 PLUMBING OVERALL SITE PLAN
13.1
121110987654321
0.9
K
J
H
G
F
C.9
C
A
1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1
H.1
CATCH BASIN
MATCHLINE A MATCHLINE A
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E C
M
AT
C H
LI
N
E B
M
AT
C H
LI
N
E B
SEE M-002 FOR CONTINUATION
OF HOT WATER PIPING
AIRCRAFT
MAINTENANCE
BAY
AIRCRAFT PARTS
SUPPLY / 102
AIRCRAFT PARTS
SUPPLY OFFICE /
CORRIDOR 3
157C
PNEUDRALICS
REPAIR SHOP
POWER PLANT/
POWERTRAIN
SHOP
STRUCTURAL
REPAIR SHOP
BLADE REPAIR
SHOP
COMSEC SECURE
STORAGE
AIRLOCK 3
157G
COMPRESSOR
ROOM
MECHANICAL
ROOM
CORRIDOR 1
157A
SHOP SECTION
HQ
PLATOON OFFICE
ORDERLY ROOM
(COMPANY D)
1ST SERGEANT
OFFICE
COMMANDER
OFFICE
AIRCRAFT
MOUNTED
WEAPONS VAULT
SYSTEMS REPAIR
SHOP
AIRLOCK 2
157F
REPAIR SECTION
WORKROOM
AIRFRAME
REPAIR PLATOON
OFFICE
AIRFRAME
REPAIR PLATOON
COMPONENT
REPAIR PLATOON
OFFICE
COMPONENT
REPAIR PLATOON
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
LOGISTICS
ASSISTANCE
REPRESENTATIVES
(LARS)
CONTRACTOR
LOGISTICS
SUPPORT
MECHANICAL
ROOM
FIRE
PROTECTION
SPECIAL TOOLS
ROOM
MEN'S
WOMEN'S
MOTHER'S ROOM
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
PRODUCTION
CONTROL
PRODUCTION
CONTROL OFFICE
QUALITY
CONTROL OFFICE
QUALITY
CONTROL
CORRIDOR 2
157B
CORRIDOR 4
157D
ARMS VAULT
(COMPANY D)
UNIT STORAGE
(COMPANY D)
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) STORAGE
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) SHOP
FACILITY
STORAGE ROOM
CREW CHIEF
WORK ROOM
(COMPANY C)
CREW CHIEF
WORK ROOM
(COMPANY A)
AIRLOCK 1
157E
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
ACN EQUIPMENT
JANITOR
MULTI PURPOSE /
BREAK / CONF
CREW CHIEF
WORK ROOM
(COMPANY B)
HEAVY AIRCRAFT
TRAFFIC RATED
TRENCH DRAIN GRATE
CATCH BASIN CATCH BASIN CATCH BASIN
RECYCLE ROOM
VESTIBULE
155A
3 3 3 3
CAGE
C152
CAGE
C149
CAGE
C147
CAGE
C108B
CAGE
C108A
CAGE
C106
NONDESTRUCTIVE
INSPECTION (NDI)
ROOM
CAGE
C101
OXYGEN
GENERATOR
ROOM
CAGE AREA
CAGE
C125
CAGE
C131
CAGE
C142
A
CD
B E
3" IW, CONNECT TO CIVIL
4" W, CONNECT TO CIVIL
8" IW, CONNECT TO CIVL
4" DCW, CONNECT TO CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-101
PL
U
M
BI
N G
P
LA
N
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/16" = 1'-0"A3 PLUMBING PLAN - AIRCRAFT MAINTENANCE HANGAR
KEY PLAN
08' 16' 32'4'12'16'
SCALE: 1/16"=1'-0"
PLAN NORTH
KEY NOTES
CREW CHIEF
WORK ROOM
(COMPANY C)
CREW CHIEF
WORK ROOM
(COMPANY B)
CREW CHIEF
WORK ROOM
(COMPANY A)
FACILITY
STORAGE ROOM
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
RECYCLE ROOM
MEN'S
WOMEN'S
SPECIAL TOOLS
ROOM
ELECTRICAL
ROOM
COMMUNICATIONS
ROOM
PRODUCTION
CONTROL
ACN EQUIPMENT
JANITOR
QUALITY
CONTROL
QUALITY
CONTROL OFFICE
PRODUCTION
CONTROL OFFICE
CORRIDOR 4
157D
CORRIDOR 2
157B
ARMS VAULT
(COMPANY D)
UNIT STORAGE
(COMPANY D)
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) STORAGE
AIRCRAFT
MAINTENANCE
BAY
AIRLOCK 1
157E
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) SHOP
P-15
7654321
0.9
C
A
1.9 2.9 3.9 4.4 5.6 6.6
MATCHLINE A
SEE SHEET P-105
MATCHLINE A
SEE SHEET P-105
P-401 D1
1" INSULATED
CONDENSATE
FROM FCU-155
TO P-19
1" INSULATED
CONDENSATE
FROM FCU 133
TO P-7
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
P-13B
P-13 P-9 P-18 P-14
P-9 P-18
P-5
P-18
FCU
FCU
P-18
P-11
1" INSULATED
CONDENSATE
FROM FCU-143
TO P-19
FCU
DH
P-19 P-10
P-13B
2"
IW
2"
IW
3" W
FCU
2" V
IW SLOPE 1/8" / 12" DN.
3" IW 3" IW
W SLOPE 1/8" / 12" DN.
2" W
3" FCO
1" INSULATED
CONDENSATE
FROM FCU 138
TO P-7
1" INSULATED
CONDENSATE
FROM DH-155
TO P-19
2" V
1" CD
1" C
D
1" CD
1" CDVESTIBULE
155A
C D
S
LO
PE
/4
2"
D N
CD SLOPE 1/4" / 12" DN.
SEE P-103
FOR PIPE
CONT.
SEE P-105
FOR PIPE
CONT.
MOTHER'S ROOM
2" VTR
2" VTR
A6 P-303
D1 P-303
P-17
3" COTG
3" FCO
CD SLOPE 1/4" / 12" DN.
2" FCO
3" FCO
2" VTR
2" V
3" CO ON VERTICAL
3" FCO
2" FCO
3" FCO
FIRE
PROTECTION
2"
IW
IW
S
LO
PE
/4
2" D
N
2" FCO
P-7
GFGI WASHER & DRYER
2" W
2" V COMMUNICATIONS
STORAGE
C146A
IW
S
LO
PE
/4
2" D
N
IW SLOPE 1/8" / 12" DN.
3" IW
4" W
2" V
4" W
W
SLO
PE 1/
4"
/ 1 2"
DN.
2"
IW
2" IW
2" IW
A
CD
B E
3" IW, REFER TO CIVIL DWGS FOR CONTINUATION
4" W, REFER TO CIVIL DWGS FOR CONTINUATION
8" IW, REFER TO CIVIL DWGS FOR CONTINUATION
2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE
DETAIL A3/P-506.
12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE
TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH
8" DIAMETER SIDE OUTLET CONNECTION
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-102
PL
U
M
BI
N G
S
AN
IT
AR
Y W
AS
TE
/V
EN
T
PL
AN
AR
EA
"A
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "A"
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.
2. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER FOOT IN DIRECTION INDICATED BY SLOPE ARROWS
3. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
5. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW FOUNDATION FOOTINGS.
6. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
KEYNOTES
SPECIAL TOOLS
ROOM
REPAIR SECTION
WORKROOM
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
FIRE
PROTECTION
MECHANICAL
ROOM
AIRFRAME
REPAIR PLATOON
OFFICE
AIRFRAME
REPAIR PLATOON
COMPONENT
REPAIR PLATOON
OFFICE
COMPONENT
REPAIR PLATOON
13.1
121110987
C.9
C
A
6.6 7.5 8.4 9.4 10.4 12.1
AIRCRAFT
MOUNTED
WEAPONS VAULT
COMSEC SECURE
STORAGE
SYSTEMS REPAIR
SHOP
POWER PLANT/
POWERTRAIN
SHOP
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
LOGISTICS
ASSISTANCE
REPRESENTATIVES
(LARS)
CONTRACTOR
LOGISTICS
SUPPORT
STRUCTURAL
REPAIR SHOP
BLADE REPAIR
SHOP
COMPRESSOR
ROOM
MECHANICAL
ROOM
SHOP SECTION
HQ
PLATOON OFFICE
ORDERLY ROOM
(COMPANY D)
1ST SERGEANT
OFFICE
COMMANDER
OFFICE
AIRCRAFT
MAINTENANCE
BAY
AIRLOCK 2
157F
CORRIDOR 1
157A
CORRIDOR 2
157B
AIRLOCK 3
157G
MATCHLINE A
SEE SHEET P-106
MATCHLINE A
SEE SHEET P-106
1" INSULATED
CONDENSATE
FROM FCU-116
TO P-19 ID
1" INSULATED
CONDENSATE
FROM FCU-132
TO P-18 ID 1" INSULATED
CONDENSATE FROM
FCU-118 TO P-19 ID
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
P-18
P-18
P-18
P-18
FCU
AHU
1" INSULATED
CONDENSATE
FROM AHU-128
TO P-19 ID
P-18
P-18
P-19
4" W
2" W
4" W
4" FCO
FCU
P-10 P-19
DH
116 1/2" INSULATED
CONDENSATE FROM
DH 116 TO P-19 ID
2"
IW
1" CD
P-14
P-18 P-9
P-14
P-18 P-9
P-19
P-13A
MAU
MAU
P-14
P-19 P-10
P-19 P-10
P-19
P-18
AHU
P-13A
P-8
FCU
1" C
D
W S
LO
PE
/8
2" D
N
1" INSULATED
CONDENSATE
FROM MAU-105
TO P-13A
2"
IW
1" INSULATED
CONDENSATE
FROM MAU-108
TO P-13A
3" FCO
1/2" CD
1" C
D
A4 P-302
P-18
1" INSULATED CONDENSATE
FROM AHU-104 TO P-18 ID
CD SLOPE 1/4" / 12" DN.
SEE
P-102
FOR PIPE
CONT.
2" VTR
A4 P-303
4" HUB DRAIN
STAND PIPE.
COORDINATE
WITH FIRE
PROTECTION.
4" W
3" IW
3" FCO
3" FCO
2" FCO
4" FCO
2" WCO
W SLOPE 1/8" / 12" DN.
SEE P-104
FOR PIPE
CONT.
3" IW
P-9
2" FCO 2" FCO
2" FCO
4" VTR
P-19
2" VTR
AD
ART
AC
AC
ERV
2" V
2" V
2" V2" V
2"
IW
2" V
2" V
2" V
1 1/2" V 2" V
2"
IW
3" IW
4" V
4" FCO
2" V
2" V
2" W P-19
P-18
P-19
2" WCO2" CO
3" IW
2"
IW
2"
IW
2" IW
4" FCO
2" W
4" W
4" W
2" W
2" W
2" W2" W
4" W
2" W
2" W
4" W
4" W
P-17
3" W W SLOPE 1/4" / 12" DN.
2" IW
4" W
2" V
2" V
3" W
2" W
1 1/2" VTR
A
CD
B E
3" IW, REFER TO CIVIL DWGS FOR CONTINUATION
4" W, REFER TO CIVIL DWGS FOR CONTINUATION
8" IW, REFER TO CIVIL DWGS FOR CONTINUATION
2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE
DETAIL A3/P-506.
12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE
TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH
8" DIAMETER SIDE OUTLET CONNECTION
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-103
PL
U
M
BI
N G
S
AN
IT
AR
Y W
AS
TE
/V
EN
T
PL
AN
AR
EA
"B
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "B"
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.
2. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.
3. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER FOOT IN DIRECTION INDICATED BY SLOPE ARROWS.
4. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.
5. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY AND DOMESTIC ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
6. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW FOUNDATION FOOTINGS.
7. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
A
CD
B E
BLADE REPAIR
SHOP
PNEUDRALICS
REPAIR SHOP
CORRIDOR 3
157C
AIRCRAFT PARTS
SUPPLY / 102
13.1
H
G
F
C.9
H.1
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
/ P -1
M
AT
C
H
LI
N E
C
SE
E
SH
EE
T
P-
/ P
-1
P-13
3" IW3" IW
IW SLOPE 1/8" / 12" DN.
D4 P-302
3" IW
SEE
P-103
P-104 A1
P-104 D1
PNEUDRALICS
REPAIR SHOP
AIRCRAFT PARTS
SUPPLY OFFICE /
IW
S
LO
PE
/4
2" D
N
2"
IW
2"
IW
2"
IW
1" C
D
C D
S
LO
PE
/4
2"
D N
. 3" IW, REFER TO CIVIL DWGS FOR CONTINUATION
4" W, REFER TO CIVIL DWGS FOR CONTINUATION
8" IW, REFER TO CIVIL DWGS FOR CONTINUATION
2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE
DETAIL A3/P-506.
12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE
TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH
8" DIAMETER SIDE OUTLET CONNECTION
P-10 P-19
P-13A
MAU
2"
IW
1" C
D
2" VTR
CORRIDOR 3
157C
PNEUDRALICS
REPAIR SHOP
1" INSULATED
CONDENSTATE DRAIN
FROM MAU-107 TO P-13A
2"
IW
2" IW
2" FCO
2" V
2" IW
2" IW
1" C
D
CD DOWN TO P-13A
13.1
F
1" CD
FCU
P-9
P-18
2"
IW
CD SLOPE 1/4" / 12" DN.
2" VTR
AIRCRAFT
MAINTENANCE
BAY
AIRCRAFT PARTS
SUPPLY OFFICE /
AIRCRAFT PARTS
SUPPLY / 102
1" INSULATED
CONDENSTATE DRAIN
FROM FCU-102 TO P-13A
2" V
2"
IW
2" IW
2" V
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-104
PL
U
M
BI
N G
S
AN
IT
AR
Y W
AS
TE
/V
EN
T
PL
AN
AR
EA
"C
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"A5 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C"
SHEET NOTES
KEY PLAN
PLUMBING KEYNOTES
1. ALL SANITARY PIPING UNDER SLAB UNLESS
OTHERWISE NOTED.
2. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS
OTHERWISE NOTED.
3. SLOPE CONDENSATE PIPING AT A RATE OF 1/4" PER
FLOOT IN DIRECTION INDICATED BY SLOPE ARROWS.
4. SLOPE SANITARY PIPEING PER IPC UNLESS
OTHERWISE NOTED.
5. COORDINATE WITH STRUCTURAL AT CONDITIONS
WHERE SANITARY PIPES ARE LOCATED BELOW SLAB
AND PENTRATE THOUGH FOUNDATION WALLS.
6. COORDINATE WITH STRUCTURAL AT CONDITIONS
WHERE SANITARY PIPES RUN BELOW FOUNDATION
FOOTINGS.
7. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE
NOTE 30 ON SHEET P-001.
1/4" = 1'-0"A1 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C" 2
1/4" = 1'-0"D1 PLUMBING SANITARY WASTE/VENT PLAN - AREA "C" 1
02' 4' 8'1'3'4'
SCALE: 1/4"=1'-0"
B E
HEAVY AIRCRAFT TRAFFIC
RATED TRENCH DRAIN GRATE
AIRCRAFT
MAINTENANCE
BAY
CATCH BASIN
INV = -4' - 1 1/2"
7654321
0.9
K
J
H
G
F
MATCHLINE A
SEE SHEET P-102
MATCHLINE A
SEE SHEET P-102
3 3
HEAVY AIRCRAFT TRAFFIC RATED
TRENCH DRAIN GRATE
TRENCH DRAIN: CHANNELS ARE PRE-SLOPED
INTERLOCKING EPS FORMS WITH STANDARD SLOPE OF
0.75%. PROVIDE WITH A GALVANIZED DUCTILE IRON
SLOTTED GRATE CLASS F RATED (DIN 19580/EN 1433). SEE
STRUCTURAL DRAWINGS FOR FURTHER INFORMATION.
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
TRENCH DRAIN
INV = -1' - 3 1/2"
@ HIGH POINT
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 4" @
HIGH POINT
HEAVY AIRCRAFT TRAFFIC RATED
TRENCH DRAIN GRATE
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 3 3/4" @
HIGH POINT
P-9 P-18
2" V
CATCH BASIN
INV = -4' - 1 1/2"
5SEE NOTE
5SEE NOTE
TRENCH DRAIN SLOPETRENCH DRAIN SLOPETRENCH DRAIN SLOPE TRENCH DRAIN SLOPE
TYP.
SEE P-102 FOR
PIPE CONT.
4 TYP.
2" IW
8"
IW
8"
IW
2" IW 2" IW2" IW 2" IW 2" IW 2" IW 2" IW
2"
IW
2" COTG
VENT PIPE
BELOW SLAB
4" VTR
VENT PIPE
BELOW SLAB
4" V
IW
S
LO
PE
/4
2" D
N
2" IW
3" IW, REFER TO CIVIL DWGS FOR CONTINUATION
4" W, REFER TO CIVIL DWGS FOR CONTINUATION
8" IW, REFER TO CIVIL DWGS FOR CONTINUATION
2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE
DETAIL A3/P-506.
12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE
TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH
8" DIAMETER SIDE OUTLET CONNECTION
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-105
PL
U
M
BI
N G
S
AN
IT
AR
Y W
AS
TE
/V
EN
T
PL
AN
AR
EA
"D
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "D"
1. BUILDING FINISHED FLOOR ELEVATION NEAR THE HANGAR DOOR IS 823.60' PER THE CIVIL DRAWINGS.
2. NO UNDERFLOOR PIPING IN HANGAR BAY UNLESS OTHERWISE NOTED.
3. SLOPE TRENCH DRAIN IN THE DIRECTION OF THE SLOPE ARROWS BY 0.75%.
4. PIPING CONNECTED TO THE HANGAR TRENCH DRAINAGE SYSTEM SHALL BE CAST IRON PIPING FROM THE
TRENCH DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.
5. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.
6. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.
7. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.
KEYNOTES
8. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE
LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
9. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW
FOUNDATION FOOTINGS.
10. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
B E
13.1
121110987
K
J
H
G
F
H.1
MATCHLINE A
SEE SHEET P-102
MATCHLINE A
SEE SHEET P-102
3 3
TRENCH DRAIN: CHANNELS ARE PRE-SLOPED
INTERLOCKING EPS FORMS WITH STANDARD SLOPE
OF 0.75%. PROVIDE WITH A GALVANIZED DUCTILE
IRON SLOTTED GRATE CLASS F RATED (DIN 19580/EN
1433). SEE STRUCTURAL DRAWINGS FOR FURTHER
INFORMATION.
AIRCRAFT
MAINTENANCE
BAY
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
CATCH BASIN
INV = -4' - 1 1/2"
TRENCH DRAIN
INV = -1' - 3 3/4" @
HIGH POINT
HEAVY AIRCREAFT TRAFFIC RATED
TRENCH DRAIN GRATE
HEAVY AIRCREAFT TRAFFIC RATED
TRENCH DRAIN GRATE
HEAVY AIRCREAFT TRAFFIC RATED
TRENCH DRAIN GRATE
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
TRENCH DRAIN
INV = -1' - 8" @
LOW POINT
CATCH BASIN
INV = -4' - 1 1/2"
TRENCH DRAIN
INV = -1' - 3 3/4" @
HIGH POINT
TRENCH DRAIN
INV = -1' - 3 1/4"
@ HIGH POINT
P-13
P-9 P-18
2" IW
2" V
2" V
SEE P-104
FOR PIPE
CONT.
5SEE NOTE
5SEE NOTE P-17
P-16
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE TRENCH DRAIN SLOPE
TYP.
SEE P-104
FOR PIPE
CONT.
SEE P-104
FOR PIPE
CONT.
SEE P-104
FOR PIPE
CONT.
4 TYP.
VENT PIPE
BELOW SLAB
VENT PIPE
BELOW SLAB
4" VTR
2" IW 2" IW 2" IW 2" IW 2" IW 2" IW 2" IW 2" IW
4" V4" V
8"
IW
8"
IW
3" IW, REFER TO CIVIL DWGS FOR CONTINUATION
4" W, REFER TO CIVIL DWGS FOR CONTINUATION
8" IW, REFER TO CIVIL DWGS FOR CONTINUATION
2" IW DRAIN FOR HANGAR DOOR RAIL TRACK. SEE
DETAIL A3/P-506.
12" WIDTH x 12" LENGTH x 50" DEPTH (BELOW THE
TOP OF GRATE) TRENCH DRAIN CATCH BASIN WITH
8" DIAMETER SIDE OUTLET CONNECTION
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-106
PL
U
M
BI
N G
S
AN
IT
AR
Y W
AS
TE
/V
EN
T
PL
AN
AR
EA
"E
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"B4 PLUMBING SANITARY WASTE/VENT PLAN - AREA "E"
KEYNOTES
1. BUILDING FINISHED FLOOR ELEVATION NEAR THE HANGAR DOOR IS 823.60' PER THE CIVIL DRAWINGS.
2. NO UNDERFLOOR PIPING IN HANGAR BAY UNLESS OTHERWISE NOTED.
3. SLOPE TRENCH DRAIN IN THE DIRECTION OF THE SLOPE ARROWS BY 0.5%.
4. PIPING CONNECTED TO THE HANGAR TRENCH DRAINAGE SYSTEM SHALL BE CAST IRON PIPING FROM THE
TRENCH DRAIN TO THE POINT OF CONNECTION OF SITE PIPING.
5. ALL SANITARY PIPING UNDER SLAB UNLESS OTHERWISE NOTED.
6. ALL SANITARY VENT PIPING ABOVE SLAB UNLESS OTHERWISE NOTED.
7. SLOPE SANITARY PIPING PER IPC UNLESS OTHERWISE NOTED.
8. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES ARE
LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
9. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE SANITARY PIPES RUN BELOW
FOUNDATION FOOTINGS.
10. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
K
K
CR
DL
SB
SB
SB
SB
C R D
L
K
K
CR
DL
SB
SB
SB
SB
C R D
L
654321
0.9
C
A
1.9 2.9 3.9 4.4 5.6 6.6
CREW CHIEF
WORK ROOM
(COMPANY C)
CREW CHIEF
WORK ROOM
(COMPANY B)
CREW CHIEF
WORK ROOM
(COMPANY A)
FACILITY
STORAGE ROOM
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
RECYCLE ROOM
MEN'S
WOMEN'S
SPECIAL TOOLS
ROOM
ELECTRICAL
ROOM
COMMUNICATIONS
ROOM
PRODUCTION
CONTROL
ACN EQUIPMENT
JANITOR
129QUALITY
CONTROL
QUALITY
CONTROL OFFICE
PRODUCTION
CONTROL OFFICE
CORRIDOR 4
157D
CORRIDOR 2
157B
UNIT STORAGE
(COMPANY D)
146AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) STORAGE
AIRCRAFT
MAINTENANCE
BAY
AIRLOCK 1
157E
CORRIDOR 2
157B
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) SHOP
MATCHLINE A
SEE SHEET P-110
MATCHLINE A
SEE SHEET P-110
P-401 D5
1 1
3/4" CW
3/4" HW
GFGI WASHER
& DRYER
P-16
P-16
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
MULTI PURPOSE /
BREAK / CONF
ARMS VAULT
(COMPANY D)
CAGE
C155B
NBC STORAGE
C146B
P-13 P-9
P-14 P-9
P-17
OXYGEN
GENERATOR
P-11
P-12 P-15
1" HW
3/4" HWR
1 1/4" CW
1/
2" C
A
1 1/2" CW
3/4" HWR
1 1/4" HW
1 1/4" CW
3/4" HWR
3/4" HW
1 1/4" HW
3/4" HWR
1 1/2" CW
3/4" HW
3/4" CW P-19
P-10
P-13B
P-5
2" HW
3/4" HWR
2 1/2" CW
1 1/2" CA
1 1/4" CW
2 1/2" CA 2 1/2" CA
P-18
SEE P-110 FOR
PIPE CONT.
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
P-401 A1
P-401 A3
P-13B
PROVIDE TAIL PIECE
TRAP PRIMER FROM
P-13B TO P-19. SEE
DETAIL E5/P-504
PROVIDE TAIL
PIECE TRAP
PRIMER FROM
P-7 TO P-18.
SEE DETAIL
E5/P-504
P-18
P-18
TRAP PRIMER
TO P-18, SEE
DETAIL D8/P-504
TRAP PRIMER
TO P-18. SEE
DETAIL D8/P-504
A6 P-303
D1 P-303
GFGI OXYGEN GENERATOR
LADDER & HATCH.
COORDINATE REQUIRED
CLEARANCE BETWEEN
PIPES AND LADDER WITH
ARCHITECTRE.
P-18
LADDER & HATCH. SEE
ARCHITECTURE SHEETS
3 3
1 1/4" CW
1" CA
PROVIDE CLAMP-ON
ULTRASONIC ENERGY
FLOWMETER ON HOT
AND COLD WATER LINE
TO CLOTHES WASHER
P-7
HW, HWR, &
CW ISOLATION
VALVES (N.O.)
COMMUNICATIONS
STORAGE
C146A
NON-SENSITIVE
SECURE
STORAGE
146A
VESTIBULE
155A
CAGE
C149CAGE
C152
1" CA 1" CA
1 1/2" CA
1/
2" C
A
1 1/2" CA
1 1/2" CA
TRAP PRIMER TO
P-11 & P-18, SEE
DETAIL D8/P-504
3/4" CW
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
HW & CW
ISOLATION
VALVE (N.O.)
ROUTE CW PIPE BRANCH
TO P-16 BELOW WINDOW
CW & HW
ISOLATION VALVE
BELOW (N.O.)
1 1/2" CA
CW ISOLATION VALVE (N.O.)
CW ISOLATION VALVE
ON VERTICAL (N.O.)
A
CD
B E
1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE
STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE
PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.
COMPRESSED AIR DROP, SEE DETAILS
COMPRESSED AIR DROP WITH HOSE REEL, SEE
DETAILS
4" DCW, CONNECT TO CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-107
PL
U
M
BI
N G
D O
M
ES
TI
C
W
AT
ER
/C
O M
PR
ES
SE
D
A
IR
PL
AN
AR
EA
"A
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.
2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.
3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.
5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "A"
PF
PFPF
CR
K C
R
SB
SB
SB
SB
CR
K C
R
SB
SB
SB
SB
PF
PFPF
A
CD
B E
13.1
121110987
C.9
C
A
6.6 7.5 8.4 9.4 10.4 12.1
SPECIAL TOOLS
ROOM
ELECTRICAL
ROOM
REPAIR SECTION
WORKROOM
COMMUNICATIONS
ROOM
FIRE
PROTECTION
MECHANICAL
ROOM
AIRFRAME
REPAIR PLATOON
OFFICE
AIRFRAME
REPAIR PLATOON
COMPONENT
REPAIR PLATOON
OFFICE
COMPONENT
REPAIR PLATOON
AIRCRAFT
MAINTENANCE
BAY
AIRCRAFT
MOUNTED
WEAPONS VAULT
COMSEC SECURE
STORAGE
SYSTEMS REPAIR
SHOP
CONTRACTOR
LOGISTICS
SUPPORT
LOGISTICS
ASSISTANCE
REPRESENTATIVES
(LARS)
COMMUNICATIONS
ROOM
ELECTRICAL
ROOM
POWER PLANT/
POWERTRAIN
SHOP
STRUCTURAL
REPAIR SHOP
CORRIDOR 1
157A
1ST SERGEANT
OFFICE
COMMANDER
OFFICE
ORDERLY ROOM
(COMPANY D)
SHOP SECTION
HQ
PLATOON OFFICE
MECHANICAL
ROOM
COMPRESSOR
ROOM
BLADE REPAIR
SHOP
AIRLOCK 3
157G
CORRIDOR 2
157B
AIRLOCK 2
157F
CORRIDOR 2
157B
NONDESTRUCTIVE
INSPECTION (NDI)
ROOM
P-17
MATCHLINE A
SEE SHEET P-111
MATCHLINE A
SEE SHEET P-111
OVERHEAD CRANE IN
SHOP REFERENCE
STRUCTURAL DRAWINGS
FOR DETAILS.
P-402 B1
P-16
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
D2 P-301
2" HW
3/4" HWR
2 1/2" CW
1 1/2" CA
1 1/2" HW
3/4" HWR
1 1/2" CA
1 1/2" HW
3/4" HWR
P-14 P-14
P-18 P-9
P-14P-18 P-9
P-16
P-18
P-18
P-18
P-18
P-8
P-19 P-18
P-13A P-13A
P-19
P-19 P-10
1" CW
1 1/2" CA
3/4" CW
P-19 P-10
P-19 P-10
3/4" HWR 1 1/4" HW
1" CW
2 1/2" CA
1 1/4" CW
1" CA
3/4" HWR
1 1/4" CW
3/4" HWR
P-17
1/2" CW
1/2" CW
1/2" CW
1/2" CW
1/ 2"
C W
1/ 2"
C W
1/2" CW
2" HW
3/4" HWR
1 1/2" CA
2 1/2" CA
2 1/2" CA
A4 P-302
AUTOMATIC TRAP
PRIMER, SEE DETAIL
D1/P-504
AUTOMATIC TRAP
PRIMER, SEE
DETAIL D1/P-504
P-401 A5
P-401 A9
P-402 B7
1 1
P-401 A7
D7 P-301
DSH HWS & R SEE MECH
FOR CONTINUATION
SEE P-111
FOR PIPE
CONT.
SEE P-109 FOR
PIPE CONT.
SEE P-107
FOR PIPE
CONT.
AUTOMATIC TRAP PRIMER,
SEE DETAIL D1/P-502
P-17
TRAP PRIMER TO
P-18. SEE DETAIL
D8/P-504.
PROVIDE TAIL PIECE TRAP
PRIMER FROM P-13A TO
P-19. SEE DETAIL E5/P-504
A4 P-303
1/2" CW
1/ 2"
C W
2 1/2" CA
AUTOMATIC TRAP
PRIMER, SEE
DETAIL D1/P-504
ETP
ETP
ETP
SEE P-107
FOR PIPE
CONT.
2 1/2" CA
SEE P-109
FOR PIPE
CONT.
P-18
TRAP PRIMER TO
P-18. SEE DETAIL
D8/P-504.
P-9
1 1/4" HW
1/2" CW LINE
TO STAND
PIPE P-TRAP
1/2" CW LINE
TO STAND
PIPE P-TRAP
BELOW
1" HW
1" CW
BELOW
1 1/4" CW 1 1/4" HW
3/4" CW
1" CW3/4" CW
1 1/4" HW
1" CA
1" CA
1" CA
1" CA
1/2" CW
2 1/2" CA
1/
2" C
A
CAGE
C108A
CAGE
C106
CAGE
C108B
3/4" CW
1" CW
1 1/2" CA
CW ISOLATION VALVE BELOW (N.O.)
CW
ISOLATION
VALVE
BELOW
HW & CW
ISOLATION VALVES
ON VERTICAL
CHILLED WATER
MAKE UP
CONNECTION
CW ISOLATION
VALVE
CW ISOLATION
VALVE
CW
ISOLATION
VALVE
HW & CW
ISOLATION VALVES
ON VERTICAL
CA ISOLATION
VALVE (N.O)
CA ISOLATION VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O.)
CA ISOLATION
VALVE (N.O)
CA ISOLATION
VALVE (N.O.)
1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE
STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE
PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.
COMPRESSED AIR DROP, SEE DETAILS
COMPRESSED AIR DROP WITH HOSE REEL, SEE
DETAILS
4" DCW, CONNECT TO CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-108
PL
U
M
BI
N G
D O
M
ES
TI
C
W
AT
ER
/C
O M
PR
ES
SE
D
A
IR
PL
AN
AR
EA
"B
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1.
1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "B"
KEYNOTES
1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.
2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.
3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.
5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
PFPF
CD
B E
13.1
H
G
F
C.9
H.1
BLADE REPAIR
SHOP
PNEUDRALICS
REPAIR SHOP
CORRIDOR 3
157C
P-16
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
/ P -1
M
AT
C
H
LI
N E
C
SE
E
SH
EE
T
P-
/ P
-1
1" CW
D4 P-302
AIRCRAFT PARTS
SUPPLY OFFICE /
AIRCRAFT PARTS
SUPPLY / 102
P-109 E2
SEE P-108
FOR PIPE
CONT.
SEE P-111
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
1/2" CA
1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE
STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE
PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.
COMPRESSED AIR DROP, SEE DETAILS
COMPRESSED AIR DROP WITH HOSE REEL, SEE
DETAILS
4" DCW, CONNECT TO CIVIL
13.1
CORRIDOR 3
157C
PNEUDRALICS
REPAIR SHOP
P-10
1" CW
1" CW
3/4" HWR
3/4" HW
P-19 P-13A
PROVIDE TAIL PIECE TRAP
PRIMER FROM P-13A TO P-19.
SEE DETAIL E5/P-504
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-109
PL
U
M
BI
N G
D O
M
ES
TI
C
W
AT
ER
/C
O M
PR
ES
SE
D
A
IR
PL
AN
AR
EA
"C
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"A5
PLUMBING DOMESTIC WATER/COMPRESSED
AIR PLAN - AREA "C"
SHEET NOTES
KEY PLAN
KEYNOTES
1/4" = 1'-0"E2
PLUMBING DOMESTIC WATER/COMPRESSED
AIR PLAN - AREA "C" - 1
1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE
STOP SYSTEMS AT ALL PENETRATIONS BETWEEN
THE HANGAR AND SHOP DEMISING WALL.
2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF
NEAREST DRAIN VALVE.
3. COORDINATE WITH STRUCTURAL AT CONDITIONS
WHERE DOMESTIC WATER PIPES ARE LOCATED
BELOW SLAB AND PENTRATE THOUGH FOUNDATION
WALLS.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS
WHERE DOMESTIC WATER PIPES RUN BELOW
FOUNDATION FOOTINGS.
5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE
NOTE 30 ON SHEET P-001.
B E
7654321
0.9
K
J
H
G
F
P-16
AIRCRAFT
MAINTENANCE
BAY
MATCHLINE A
SEE SHEET P-107
MATCHLINE A
SEE SHEET P-107
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
P-9
P-18
P-17
1 1/4" CW
1" CA
1" CW
FLOOR MOUNTED
HOSE REELS (TYP)
1 1 1
1-1/2" CA UP 1-1/2" CA UP 1-1/2" CA UP
AUTOMATIC TRAP
PRIMER, SEE
DETAIL D1/P-504
ETP
SEE P-107
FOR PIPE
CONT.
SEE P-107
FOR PIPE
CONT.
SEE P-107
FOR PIPE
CONT.
SEE P-107
FOR PIPE
CONT.
1" CW
CRANE SYSTEM,
SEE STRUCTURAL.
FOAM
SUPPRESSION
SYSTEM, SEE FIRE
PROTECTION, TYP.
1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE
STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE
PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.
COMPRESSED AIR DROP, SEE DETAILS
COMPRESSED AIR DROP WITH HOSE REEL, SEE
DETAILS
4" DCW, CONNECT TO CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-110
PL
U
M
BI
N G
D O
M
ES
TI
C
W
AT
ER
/C
O M
PR
ES
SE
D
A
IR
PL
AN
AR
EA
"D
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "D"
KEYNOTES
1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.
2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.
3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.
5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
121110987
K
J
H
G
F
H.1
MATCHLINE A
SEE SHEET P-108
MATCHLINE A
SEE SHEET P-108
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E C
SE
E
SH
EE
T P-
P-13
P-9 P-18
1" CA
1 1/4" HW
3/4" HWR
FLOOR MOUNTED
HOSE REEL (TYP)
D4 P-302
1-1/2" CA UP
1 1
1-1/2" CA UP 1-1/2" CA UP
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
M
AT
C H
LI
N
E B
SE
E
SH
EE
T P-
P-17 P-16
AIRCRAFT
MAINTENANCE
BAY
PROVIDE TAIL
PIECE TRAP
PRIMER FROM
P-13 TO P-18. SEE
DETAIL E5/P-504.
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
CA ISOLATION VALVE
ON VERTICAL (N.O.)
A
CD
B E
1 1-1/2" UNDER SLAB COMPRESSED AIR ROUTED ABOVE
STRUCTURAL FOOTING AND BELOW SLAB. PROVIDE
PIPE WITH THERMOPLASTIC SHEATH, SEE SPECS.
COMPRESSED AIR DROP, SEE DETAILS
COMPRESSED AIR DROP WITH HOSE REEL, SEE
DETAILS
4" DCW, CONNECT TO CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-111
PL
U
M
BI
N G
D O
M
ES
TI
C
W
AT
ER
/C
O M
PR
ES
SE
D
A
IR
PL
AN
AR
EA
"E
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
KEY PLANSHEET NOTES
04' 8' 16'2'6'8'
SCALE: 1/8"=1'-0"
PLAN NORTH
1/8" = 1'-0"B4 PLUMBING DOMESTIC WATER/COMPRESSED AIR PLAN - AREA "E"
KEYNOTES
1. PROVIDE U.L. RATED THROUGH - PENETRATION FIRE STOP SYSTEMS AT ALL PENETRATIONS BETWEEN THE HANGAR AND SHOP DEMISING WALL.
2. SLOPE COMPRESSED AIR PIPING IN DIRECTION OF NEAREST DRAIN VALVE.
3. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES ARE LOCATED BELOW SLAB AND PENTRATE THOUGH FOUNDATION WALLS.
4. COORDINATE WITH STRUCTURAL AT CONDITIONS WHERE DOMESTIC WATER PIPES RUN BELOW FOUNDATION FOOTINGS.
5. PROVIDE PIPE EXPANSION JOINTS AS REQUIRED. SEE NOTE 30 ON SHEET P-001.
121110987654321
0.9
K
J
H
G
F
C.9
C
A
1.9 2.9 3.9 4.4 5.6 6.6 7.5 8.4 9.4 10.4 12.1
H.1
6"x6" MA INTAKE
12"x12" MA INTAKE
18"x16" OA INTAKE 10"x10" MA INTAKE 16"x16" OA INTAKE
12"x12" EA OUTLET
6"x6" EA OUTLET
14"x14" MA INTAKE
10"x10" MA INTAKE
24"x24" EA DUCT
UP TO EF-105
6"x6" EA OUTLET
20"x20" EA OUTLET
18"x18" MA INTAKE
8"x8" EA OUTLET
18"x18" MA INTAKE
16"x16" EA OUTLET
14"x14" MA INTAKE
4" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
2" VTR
6"x6" EA OUTLET
ROOF HATCH, SEE
ARCHITECTURE
10"x10" EA OUTLET
40"x20" EA OUTLET
4" VTR
2" VTR
2" VTR
1 1/2" VTR
2" VTR
4" VTR 4" VTR
EF
EF
12"x12" EA DUCT
UP TO EF-155
WALKING PADS, SEE
ARCHITECTURE TYP.
ROOF HATCH, SEE
ARCHITECTURE
12"x12" EA OUTLET
A
CD
B E
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-112
PL
U
M
BI
N G
R O
O F
PL
AN
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/16" = 1'-0"B4 PLUMBING ROOF PLAN
PLAN NORTH
08' 16' 32'4'12'16'
SCALE: 1/16"=1'-0"
1. COORDINATE ALL ROOF PENETRATIONS WITH ARCHITECTURAL AND STRUCTURAL
KEY PLANGENERAL NOTES KEYNOTES
01_FINISH FLOOR
0' - 0"
A
HWST
EHWH
EHWH
ET
STRAINER
1 1/2" CA
GATE VALVE
GATE VALVE
WATER METER
SYSTEM DRAIN
2" HW
2" HWR
BMV-1
HIGH-LOW THERMOSTATIC
MIXING VALVE
CORRIDOR 2
157B
MECHANICAL
ROOM
HWR BALANCING VALVE,
BALANCE TO 3.0 GPM
HWRP
2 1/2" CW
2 1/2" HW
1" HWR
8"x8"
SEE CIVIL FOR PIPE CONT.
TBP
ETP
AUTOMATIC TRAP
PRIMER, SEE
DETAIL D1/P-504
2" HW 2 1/2" CW
1" CW
2" HW
P-19
2" HWR 2" HW BEHIND
1 1/2" HW
1" HWR
3" CW
1" HWR
1 1/2" HW2" CW
2" CW
1" HW
1/2" CW
2 1/2" HW2" HW1 1/2" HW1 1/2" HW
4" CW
3" CW
4" CW
10"x18"
2 1/2" CW3/4" CW
01_FINISH FLOOR
0' - 0"
C
CABLE TRAY,
SEE ELECTRICAL
LOCATE PIPES PARALLEL WITH THE
CABLE TRAY AND ON THE OPPOSITE
WALL IN COORDIDORS.
WHERE PIPES CROSS OVER CABLE TRAY,
PROVIDE A MINIMUM 12" CLEARANCE
BETWEEN TOP OF CABLE TRAY AND
BOTTOM OF PIPES.
CORRIDOR 2
157B
20"x18" 20"x20"
1 1/2" CA
2 1/2" CW
2" HW
3/4" HWR
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-301
PL
U
M
BI
N G
B U
IL
D
IN
G
S
EC
TI
O
N
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
3/8" = 1'-0"D2 MECH ROOM DOMESTIC WATER SECTION
3/8" = 1'-0"D7 SECTION AT CORRIDOR 2 157B
02' 4'1'3'4'
SCALE: 3/8"=1'-0"
02_BO_ADMIN
ROOF STRUCT
18' - 0"
03_TO_PARAPET_ADMIN
ROOF
19' - 4"
121110.4 12.1
P-19
3/4" HWR1 1/4" HW
2" IW
P-13A
CA DROP "TYPE A",
SEE SHEET A1/P907
3/4" HW
2" IW
POWER PLANT/
POWERTRAIN
SHOP
AIRLOCK 3
157G
COMSEC SECURE
STORAGE
STRUCTURAL
REPAIR SHOP
12"x12"
"x
1 1/2" CW
P-9
2" V
BEHIND BEHIND
2" V
3/4" HW
1" CD
3/4" CW2" V
1 1/4" CW
1 1/4" HW
2" V
1" C
A
1" C
A
1" C
A
1" CA
01_FINISH FLOOR
0' - 0"
02_BO_ADMIN
ROOF STRUCT
18' - 0"
03_TO_PARAPET_ADMIN
ROOF
19' - 4"
H G FH.1
P-13 P-9
P-18
1/2" CA
3/4" HW
3/4" CW
2" V
2" IW 2" IW
CA DROP "TYPE A",
SEE SHEET A1/P907
CA DROP "TYPE A",
SEE SHEET A1/P907
3/4" HW
AIRCRAFT
MAINTENANCE
BAY
BLADE REPAIR
SHOP
1/2" CA
2" V
1" CW
P-17
1" CW
3/4" HWR
1" CA
1 1/4" HW 3/4" HWR 1 1/4" CW
BEHIND BEHIND BEHIND
FOAM TANK CONTAINMENT
SYSTEM MONITORING
PANEL , SEE MECHANICAL
1 1/4" CW
1/2" CA
1" CA
1" CW
2" V
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-302
PL
U
M
BI
N G
B U
IL
D
IN
G
S
EC
TI
O
N
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/4" = 1'-0"A4 SECTION VIEW - GRIDLINE 'F' (10.4 - 12.1)
1/4" = 1'-0"D4 SECTION VIEW - GRIDLINE '13' (F - H.1)
02_BO_ADMIN
ROOF STRUCT
18' - 0"
03_TO_PARAPET_ADMIN
ROOF
19' - 4"
5 4.45.6
P-9
P-18
P-14
2 1/2" CA 2 1/2" CA
26"x26"32"x20" 20"x20"
"x
1 1/4" CW
1" CA
EF
AIRCRAFT
MAINTENANCE
BAY
P-17
01_FINISH FLOOR
0' - 0"
02_BO_ADMIN
ROOF STRUCT
18' - 0"
03_TO_PARAPET_ADMIN
ROOF
19' - 4"
10 9 8 7.58.49.410.4
AIRCRAFT
MAINTENANCE
BAY
26"x26"
12"x12"
32"x20"
"x
20"x20"
"x
P-14
P-9
P-18
P-14
TRAP PRIMER, SEE
DETAIL A8/P-5031 1/4" CW
3/4" CW
1" CA
EF
100B EF
P-17
2 1/2" CA 2 1/2" CA2 1/2" CA
2" V
1" CW 1" HW
1 1/2" V
2" IW
2" IW
2" IW
1 1/2" V 1" HW
1" CW
1 1/4" HW 1 1/4" CW 1" HW
01_FINISH FLOOR
0' - 0"
02_BO_ADMIN
ROOF STRUCT
18' - 0"
03_TO_PARAPET_ADMIN
ROOF
19' - 4"
3 22.9
2" V
1 1/4" CW
1/2" CW
3/4" HW
2" V
3/4" CW
TRAP PRIMER, SEE
DETAIL A8/P-503
2" IWP-18
P-9
P-13
AIRCRAFT
MAINTENANCE
BAY
2 1/2" CA
20"x20"
"x
32"x20"
"x
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-303
PL
U
M
BI
N G
B U
IL
D
IN
G
S
EC
TI
O
N
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/4" = 1'-0"A6 SECTION VIEW - GRIDLINE 'C' (4.4 - 5.6)
1/4" = 1'-0"A4 SECTION VIEW - GRIDLINE 'C' (7.5 - 10.4)
1/4" = 1'-0"D1 SECTION VIEW - GRIDLINE 'C' (2 - 3)
JJD
D
D
D
54.4 5.6
P-18
P-2 P-2 P-4A P-4 P-4
P-18
P-18
P-4 P-4 P-4 P-4
P-1AP-1P-1P-1P-1
P-1 P-1 P-1 P-1A
P-4A
P-4
P-4
P-18A
P-18
P-6
P-3 P-3
1 1/2" HW1 1/2" CW
3/4" HW
MEN'S
WOMEN'S
MOTHER'S ROOM
AUTOMATIC TRAP
PRIMER. SEE
DETAIL D1/P-504
ETP-126 ISOLATION VALVE
AUTOMATIC TRAP
PRIMER. SEE
DETAIL D1/P-504
1/2" CW 1/2" CW
DCW WATER
HAMMER
ARRESTOR,
PDI SIZE C
DCW WATER HAMMER
ARRESTOR, PDI SIZE B
ETP
ETP
P-12 P-12
HWR BALANCING
VALVE. BALANCE
TO 0.5 GPM
SEE P-107
FOR PIPE
CONT.
SEE P-107
FOR PIPE
CONT.
SEE P-107
FOR PIPE
CONT.
P-18A P-18A P-18A
P-18AP-18AP-18AP-18A
P-18A
P-18A
P-8
SEE P-107
FOR PIPE
CONT.
1 1/4" HW
3/4" HWR
2 1/2" CW
1 1/4" HW
2 1/2" CW
1/2" HW
1/2" CW1/2" CW
SEE P-107
FOR PIPE
CONT.
DCW HAMMER
ARRESTOR, PDI SIZE C
DCW HAMMER
ARRESTOR,
PDI SIZE B
DCW HAMMER
ARRESTOR, PDI SIZE D
P-3 P-3 P-3
3/4" HW 3/4" CW
1/2" CW
ETP-127 ISOLATION VALVE
HW ISOLATION
VALVE (N.O.)
CW ISOLATION
VALVE (N.O.)
1" HW
1" CW
1/2" CW
HW, CW, HWR,
ISOLATION
VALVE (N.O.)
1 1/4" HW
3/4" HWR
1 1/2" CW
1 1/2" CW
2" HW
3/4" HWR
2 1/2" CW
54.4 5.6
P-18
P-18
P-6
P-4AP-2
P-2
P-4 P-4
P-18
3" IW
P-1 P-1 P-1 P-1 P-1A
MEN'S
WOMEN'S
P-1 P-1 P-1 P-1A
P-3 P-3
P-4 P-4 P-4 P-4
P-4A
P-4
P-4
MOTHER'S ROOM
2" WCO
SEE P-102
FOR PIPE
CONT.
SEE P-102
FOR PIPE
CONT.
SEE P-102
FOR PIPE
CONT.
SEE P-102
FOR PIPE
CONT.
SEE P-102
FOR PIPE
CONT.
P-18A P-18A P-18A
P-18A P-18A P-18A P-18A
P-18
P-18A
P-18A
P-18A
P-8
P-12 P-12
P-3 P-3 P-3
2" FCO
4" VTR
3" IW
4" V
2"
IW
2" V
2" V
3" FCO
4" FCO
2" W
2" W
2" IW
2" W
4" FCO
SEE P-102
FOR PIPE
CONT.
SEE P-102
FOR PIPE
CONT.
2" FCO
4" W
2" W2" W 2" W
4" W
3" W 4" W
2" W
2" W
2" W
2" W
3" W 2" W
4" W
3" W
2" W 2" W
2" W 2" W 2" W 2" W
2" W
4" W
3" W 3" W 3" W 3" W 3" W
3" W 3" W 3" W 3" W
3" W
3" W
3" V
2" V
2" V
2" V
3" V
2" V
2" W
CORRIDOR 2
157B
AVIATION LIFE
SUPPORT
EQUIPMENT
(ALSE) SHOP
1" HW
3/4" HWR
1 1/4" CW
1 1/4" HW
3/4" HWR
1 1/2" CW
HWR BALANCING
VALVE, BALANCE
TO 0.5 GPM
HWR BALANCING VALVE,
BALANCE TO 0.5 GPM
ISOLATION
VALVE (TYP)
1 1/4" CW
3/4" HWR
3/4" HW
1 1/2" CA
1" C
A
5.6
3/ 4"
H W
R 2"
H W
1 1/4" HW
3/4" HWR
2 1/2" CW
1 1/2" CA
2" HW
3/4" HWR
HWR BALANCING VALVE,
BALANCE TO 0.5 GPM
MOTHER'S ROOM
CORRIDOR 2
157B
1/
2" C
W
ISOLATION VALVE
(TYP) 2" HW
3/4" HWR
1 1/2" CA
1 1/2" HW
2" CW
1 1/2" CA
HWR BALANCING
VALVE, BALANCE
TO 1.5 GPM
HWR BALANCING
VALVE, BALANCE
TO 1.5 GPM
FIRE
PROTECTION
MECHANICAL
ROOM
CORRIDOR 2
157B ISOLATION
VALVE (TYP)
HWRP
2 1/2" CW
3/4" CW ETP
1" HWR
3/4" HWR
13.1
3/4" HWR
1 1/2" CW
HWR BALANCING
VALVE. BALANCE
TO 0.5 GPM
HWR BALANCING
VALVE. BALANCE
TO 0.5 GPM
AIRCRAFT
MAINTENANCE
BAY
PNEUDRALICS
REPAIR SHOP
BLADE REPAIR
SHOP
HWR BALANCING
VALVE. BALANCE
TO 1 GPM
1 1/4" HW
1" CA ISOLATION
VALVE (TYP)
CABLE TRAY BELOW PIPES.
PROVIDE MIN CLEARANCE OF
1'-0" BETWEEN BOTTOM OF
PIPE AND TOP OF CABLE TRAY
3/4" HW
3/4" HWR
1" CW
1/
4" H
W
3/ 4"
H W
R
1/
4" C
W
10.4
HWR BALANCING
VALVE. BALANCE
TO 0.5 GPM
AIRCRAFT
MAINTENANCE
BAY
COMSEC SECURE
STORAGE
AIRLOCK 3
157G
HWR BALANCING VALVE.
BALANCE TO 1 GPM
1 1/4" HW
3/4" HWR
ISOLATION
VALVE (TYP)
1 1/2" CW
1 1/2" HW
3/4" HWR 2" CW
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-401
PL
U
M
BI
N G
E N
LA
R
G
ED
P
LA
N S
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
H
AN
G
AR
1/4" = 1'-0"D5 ENLARGED DOMESTIC WATER RESTROOM PLAN
1/4" = 1'-0"D1 ENLARGED SANITARY WASTE/VENT RESTROOM PLAN
1/2" = 1'-0"A1 ENLARGED PLAN VIEW 1
1/2" = 1'-0"A3 ENLARGED PLAN VIEW 2
1/2" = 1'-0"A5 ENLARGED PLAN VIEW 3
1/2" = 1'-0"A9 ENLARGED PLAN VIEW 5
1/2" = 1'-0"A7 ENLARGED PLAN VIEW 4
01' 3'2'3'
SCALE: 1/2"=1'-0"
8.4
D2 P-301
BUILDING WATER
METER (M-1), SEE
SPEC 22.00.00 FOR
REQIREMENTS
ET
P-18
P-18
P-19
1 1/2" HW
1/2" CW
1/2" CW
P-17
HWP
HWP
BMV-1
1 1/2" HW
3/4" HWR
1 1/2" CA
2 1/2" HW
EHWH
EHWH
HWST
1" HWR
3" CW
2" HWR
2" HW
2" HW
4" CW
MECHANICAL
ROOM
AUTOMATIC TRAP
PRIMER SEE DETAIL
D1/P-504
HWRP
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
DSH HWS & R
SEE MECH FOR
CONTINUATION
HWR BALANCING VALVE,
BALANCE TO 1.5 GPM
ETP
SEE CIVIL FOR
PIPE CONT.
PROVIDE CLAMP-ON
ULTRASONIC ENERGY
FLOWMETER ON HW
SUPPLY LINE (SM-2)
FROM EHWH-1 AND
EHWH-2.
TBP
P-19
3" CW
2 1/2" CW 1" HWR2 1/2" HW
2" CW
CW ISOLATION VALVE
2" HWR
2" HW
1 1/2" HW
1 1/2" HW
2" CW
1/2" CW
1/2" CW
2" CW
2 1/2" CW
1 1/2" HW
3/4" HWR
13.1
A
P-16
P-17
SEE P-108
FOR PIPE
CONT.
SEE P-108
FOR PIPE
CONT.
COALESCING FILTER
AUTOMATIC TRAP
PRIMER. SEE DETAIL
D1/P-504
PARTICULATE FILTER
ETP
COMPRESSOR
ROOM
P-19
P-18
P-19
ART
AD
AC
AC
3/ 4"
C W
1/
2" C
A
1" C
W
1" C
D
ISOLATION VALVE (TYP)
PRESSURE GUAGE
1/ 2"
C W2
1/ 2"
C A
2 1/2" CA
1" CD
1" CD
1" CD
3/ 4"
C W
2" CA
2 1/2" CA
CONDENSATE FROM
AD-1 TO P-19 ID
CONDENSATE FROM
ART-1 TO P-19 ID
ALL CONDENSATE FROM AC-2 & AC-1 TO P-19 ID
1/ 2"
C W
FLEXIBLE CONNECTOR, TYP.
PRESSURE REGULATOR
(SET TO 110 PSI)
SEE P-108
FOR PIPE
CONT.
1/2" CW
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
P-402
PL
U
M
BI
N G
E N
LA
R
G
ED
P
LA
N S
H O
N O
LU
LU
D
IS
TR
IC
T
FT
. S H
AF
TE
R , H
AW
AI
I 9
R
EG
IO
N
AL
E
N G
IN
EE
R
IN
G C
EN
TE
R H
O N
O
LU
LU
D
IS
TR
IC
T
H O
N O
LU
LU
, H I
TS
, D
N
TS KAKM
J
AN
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
DESIGN COMPLETE REV 12 JAN 2021
W H
EE
LE
R A
R M
Y
AI
R
FI
EL
D
, O
AH
U , H
AW
AI
I
FY
M
C A
PN
AI
R
C R
AF
T
M
AI
N
TE
N
AN
C E
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .