This is a technical specification document for sectional overhead doors at Tinker Air Force Base, Oklahoma, dated April 2019.

The specification establishes comprehensive requirements for the design, fabrication, materials, and installation of sectional overhead doors. Door types include standard lift, low headroom, high lift, and vertical lift designs, with operation options via lifting handles, hand chain/crank, or electric power with manual chain backup. Steel doors must be fabricated from hot-dipped galvanized steel not lighter than 20 gauge with integral reinforcing ribs or 24 gauge with reinforcing ribs and V-grooves, with minimum 2-inch section thickness and interlocking meeting rails for weathertight closure. Aluminum sections are permitted as contractor options with equivalent structural and thermal properties. Insulated sections must achieve a U-factor of 0.27 or less using plastic foam or equivalent insulation, covered with steel sheets not lighter than 27 gauge. Doors must comply with ANSI/DASMA 102 specifications and be tested per ASTM E330/E330M or ANSI/DASMA 108 standards to meet acceptance criteria for structural performance under uniform static air pressure. Tracks must be galvanized steel (14 gauge minimum for 2-inch tracks, 12 gauge for 3-inch tracks), and hardware including hinges, brackets, rollers, and locking devices must be galvanized steel (14 gauge) with ball-bearing rollers and case-hardened races. Electric operators must be UL 325-listed, include machine-cut gears, magnetic brakes, pushbutton controls, limit switches, and entrapment protection devices that immediately stop and reverse doors upon sensing obstructions. All ferrous metal surfaces require hot-dip galvanization per ASTM A123/A123M with shop prime coating; aluminum surfaces require clear anodized finish per AA DAF45 standards. Contractor quality control submittals include shop drawings with detailed installation specifications and product data for doors and electric operators. Installation must follow NFPA 70 electrical code requirements with complete functional testing and operator demonstration upon completion.

View the file

Other files

File Type Posted
190023 Reno Restrooms B117 Pre Bid RFI Follow Up_COR_Signed.pdf PDF
02 41 00.pdf PDF
06 10 00.pdf PDF
07 12 00.pdf PDF
07 42 13.pdf PDF
07 42 63.pdf PDF
07 53 23.pdf PDF
07 54 19.pdf PDF
07 62 13.pdf PDF
08 41 13.pdf PDF
08 51 13.pdf PDF
08 51 23.pdf PDF
09 51 00.pdf PDF
09 65 00.pdf PDF
10 14 00.20.pdf PDF
22 05 48.00 20.pdf PDF
23 01 30.41.pdf PDF
23 05 93.pdf PDF
23 36 00.00 40.pdf PDF
23 54 16 .pdf PDF
23 57 10.pdf PDF
23 81 00.pdf PDF
23 82 23.00 40.pdf PDF
23 82 46.00 40.pdf PDF
26 42 14.00 10.pdf PDF
26 51 00.pdf PDF
26 56 20.00 10.pdf PDF
28 31 33.00 10.pdf PDF
31 00 00.pdf PDF
32 01 17.pdf PDF
32 01 18.pdf PDF
32 01 22.pdf PDF
32 12 15.pdf PDF
32 31 13.pdf PDF
03 39 00.00 10.pdf PDF
03 62 16.pdf PDF
04 20 00.pdf PDF
05 21 00.pdf PDF
06 20 00.pdf PDF
06 61 16.pdf PDF
07 60 00.pdf PDF
00 72 00.pdf PDF
00 80 00.pdf PDF
00 71 00.pdf PDF
01 78 23.pdf PDF
Att11_190023_Submittal Register_Final.pdf PDF
Wage Determination.pdf PDF
Solicitation - FA813726R0030.pdf PDF
Att10_190023_SOW.pdf PDF
EAL List - BLANK to Contractors WWYK190023.xlsx XLSX spreadsheet
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Ti nker AFB, OK TAFB Techni cal Spr ci f i cat i ons 2019

SECTI ON 08 36 13

SECTI ONAL OVERHEAD DOORS

PART 1 GENERAL

1. 1 REFERENCES

The publ i cat i ons l i s t ed bel ow f or m a par t of t hi s speci f i cat i on t o t he ext ent r ef er enced. The publ i cat i ons ar e r ef er r ed t o i n t he t ext by t he basi c desi gnat i on onl y.

ALUMI NUM ASSOCI ATI ON ( AA)

AA DAF45 ( 2003; Reaf f i r med 2009) Desi gnat i on Syst em f or Al umi num Fi ni shes

ASTM I NTERNATI ONAL ( ASTM)

ASTM A123/ A123M ( 2013) St andar d Speci f i cat i on f or Zi nc ( Hot - Di p Gal vani zed) Coat i ngs on I r on and St eel Pr oduct s

ASTM A227/ A227M ( 2006; R 2011) St andar d Speci f i cat i on f or St eel Wi r e, Col d- Dr awn f or Mechani cal Springs

ASTM A229/ A229M ( 2012) St andar d Speci f i cat i on f or St eel Wi r e, Oi l - Temper ed f or Mechani cal Spr i ngs

ASTM A36/ A36M ( 2014) St andar d Speci f i cat i on f or Car bon St r uct ur al St eel

ASTM A653/ A653M ( 2015; E 2016) St andar d Speci f i cat i on f or St eel Sheet , Zi nc- Coat ed ( Gal vani zed) or Zi nc- I r on Al l oy- Coat ed ( Gal vanneal ed) by t he Hot - Di p Pr ocess

ASTM B209 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e

ASTM B209M ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Sheet and Pl at e ( Met r i c)

ASTM B221 ( 2014) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes

ASTM B221M ( 2013) St andar d Speci f i cat i on f or Al umi num and Al umi num- Al l oy Ext r uded Bar s, Rods, Wi r e, Pr of i l es, and Tubes ( Met r i c)

ASTM E330/ E330M ( 2014) St r uct ur al Per f or mance of Ext er i or Wi ndows, Door s, Skyl i ght s and Cur t ai n Wal l s by Uni f or m St at i c Ai r Pr essur e Difference

Apr i l 2019 Page 1 SECTI ON 08 36 13

DOOR AND ACCESS SYSTEM MANUFACTURERS ASSOCI ATI ON ( DASMA)

ANSI / DASMA 102 ( 2011) Speci f i cat i ons f or Sect i onal Over head- Type Door s

ANSI / DASMA 108 ( 2005) St andar d Met hod f or Test i ng Sect i onal Gar age Door s and Rol l i ng Door s:

Det er mi nat i on of St r uct ur al Per f or mance Under Uni f or m St at i c Ai r Pr essur e Difference

NATI ONAL ASSOCI ATI ON OF ARCHI TECTURAL METAL MANUFACTURERS ( NAAMM)

NAAMM AMP 500 ( 2006) Met al Fi ni shes Manual

NATI ONAL ELECTRI CAL MANUFACTURERS ASSOCI ATI ON ( NEMA)

NEMA I CS 1 ( 2000; R 2015) St andar d f or I ndust r i al Cont r ol and Syst ems: Gener al Requi r ement s

NEMA I CS 2 ( 2000; R 2005; Er r at a 2008) I ndust r i al Cont r ol and Syst ems Cont r ol l er s, Cont act or s, and Over l oad Rel ays Rat ed 600 V

NEMA I CS 6 ( 1993; R 2011) I ndust r i al Cont r ol and Syst ems: Encl osur es

NEMA MG 1 ( 2016) Mot or s and Gener at or s

NEMA ST 20 ( 1992; R 1997) St andar d f or Dr y- Type Tr ansf or mer s f or Gener al Appl i cat i ons

NATI ONAL FI RE PROTECTI ON ASSOCI ATI ON ( NFPA)

NFPA 70 ( 2017) Nat i onal El ect r i cal Code

UNDERWRI TERS LABORATORI ES ( UL)

UL 325 ( 2013; Repr i nt Dec 2016) UL St andar d f or Saf et y Door , Dr aper y, Gat e, Louver , and Wi ndow Oper at or s and Syst ems

1. 2 SUBMITTALS

Gover nment appr oval i s r equi r ed f or submi t t al s wi t h a " G" desi gnat i on;

submi t t al s not havi ng a " G" desi gnat i on ar e f or Cont r act or Qual i t y Cont r ol appr oval . Submi t t he f ol l owi ng i n accor dance wi t h Sect i on 01 33 00

SUBMI TTAL PROCEDURES:

SD- 02 Shop Dr awi ngs

Door s; G

Show t ypes, s i zes, l ocat i ons, met al gages i ncl udi ng mi ni mum met al deci mal t hi ckness, har dwar e pr ovi s i ons, i nst al l at i on det ai l s, and ot her det ai l s of const r uct i on. For el ect r i cal l y- oper at ed door s, i ncl ude suppor t i ng br acket s f or mot or s, l ocat i on, t ype, and r at i ngs of mot or s, swi t ches, and saf et y devi ces.

Apr i l 2019 Page 2 SECTI ON 08 36 13

SD- 03 Pr oduct Dat a

Door s; G

El ect r i c oper at or s; G

For el ect r i cal l y mot or - oper at ed door s, submi t manuf act ur er ' s wi r i ng di agr ams f or mot or and cont r ol s.

SD- 08 Manuf act ur er ' s I nst r uct i ons

Doors

SD- 10 Oper at i on and Mai nt enance Dat a

Door s; G

Submi t Dat a Package 2 i n accor dance wi t h Sect i on 01 78 23

OPERATI ON AND MAI NTENANCE DATA.

1. 3 DELI VERY, STORAGE, AND HANDLI NG

Pr ot ect door s and accessor i es f r om damage dur i ng del i ver y, st or age, and handl i ng. Cl ear l y mar k manuf act ur er ' s br and name. St or e door s i n dr y l ocat i ons wi t h adequat e vent i l at i on, f r ee f r om dust and wat er . Remove damaged i t ems and pr ovi de new. Pr ovi de easy access f or i nspect i on and handl i ng of over head door s pr i or t o i nst al l at i on.

PART 2 PRODUCTS

2. 1 MATERIALS

2. 1. 1 Har d- Dr awn Spr i ngwi r e

ASTM A227/ A227M.

2. 1. 2 Oi l - Temper ed Spr i ngwi r e

ASTM A229/ A229M.

2. 1. 3 St eel Sheet

ASTM A653/ A653M.

2. 1. 4 St eel Shapes

ASTM A36/ A36M.

2. 1. 5 Al umi num Ext r usi ons

ASTM B221, Al l oy 6063- T5.

2. 1. 6 Al umi num Sheet s and St r i ps

ASTM B209, al l oy and t emper best sui t ed f or t he pur pose.

Apr i l 2019 Page 3 SECTI ON 08 36 13

2. 1. 7 Glass

Ful l y t emper ed, c l ear f l oat gl ass 1/ 8 i nch t hi ck.

2. 2 DOORS

Door s shal l compl y wi t h ANSI / DASMA 102. Met al door s t o have hor i zont al sect i ons hi nged t oget her whi ch oper at e i n a syst em of t r acks t o compl et el y c l ose t he door openi ng i n t he c l osed posi t i on and make t he f ul l wi dt h and hei ght of t he door openi ng avai l abl e f or use i n t he open posi t i on.

Pr ovi de a per manent l abel on t he door i ndi cat i ng t he name and addr ess of t he manuf act ur er . Pr ovi de door s wi t h one of t he f ol l owi ng ( as speci f i ed i n cont r act dr awi ngs) :

a. st andar d l i f t t ype desi gned t o s l i de up and back i nt o a hor i zont al over head posi t i on and r equi r i ng a maxi mum of 16 i nch of headr oom f or 2 i nch t r acks and 21 i nch of headr oom f or 3 i nch t r acks;

b. l ow headr oom t ype desi gned t o s l i de up and back i nt o a hor i zont al over head posi t i on and r equi r i ng a maxi mum of 10 i nch of headr oom f or 2 i nch t r acks and 12 i nch of headr oom f or 3 i nch t r acks;

c. hi gh l i f t t ype desi gned t o s l i de up and back i nt o a combi nat i on ver t i cal and hor i zont al posi t i on;

d. ver t i cal l i f t t ype desi gned t o s l i de upwar d i nt o a ver t i cal position .

Door s oper at e by l i f t i ng handl es; by hand chai n wi t h gear or spr ocket r educt i on; by hand cr ank wi t h gear or spr ocket r educt i on; or by el ect r i c power wi t h auxi l i ar y hand chai n oper at i on ( as speci f i ed i n t he cont r act drawings).

2. 3 DESI GN REQUI REMENTS

Desi gn wi nd l oad shal l conf or m t o t he desi gn wi nd l oad f or t he bui l di ng of door ar ea wi t hout damage. Door s shal l be t est ed i n accor dance wi t h ei t her ASTM E330/ E330M or ANSI / DASMA 108 and shal l meet t he accept ance cr i t er i a of ANSI / DASMA 108.

2. 4 FABRICATION

2. 4. 1 St eel Over head Door s

For m door sect i ons of hot - di pped gal vani zed st eel not l i ght er t han 20 gage wi t h l ongi t udi nal i nt egr al r ei nf or ci ng r i bs or 24 gage wi t h l ongi t udi nal i nt egr al r ei nf or ci ng r i bs and f l at bot t om V- gr ooves. I nst al l sect i ons not l ess t han 2 i nch i n t hi ckness. Meet i ng r ai l s t o have i nt er l ocki ng j oi nt s t o ensur e a weat her t i ght c l osur e and al i gnment f or f ul l wi dt h of t he door . Pr ovi de sect i ons of t he hei ght i ndi cat ed or t he manuf act ur er ' s st andar d. Do not exceed t hi ck 24 i nch hei ght f or i nt er medi at e sect i ons.

Bot t om sect i ons may be var i ed t o sui t door hei ght . Do not exceed 30 i nch hei ght f or bot t om sect i on. Pr ovi de gl ass panel s i f i ndi cat ed and i nst al l panel s usi ng manuf act ur er ' s st andar d f or r ubber gasket s.

2. 4. 1. 1 I nsul at ed Sect i ons

I nsul at e door sect i ons wi t h pl ast i c f oam or ot her mat er i al pr ovi di ng a " U" f act or of 0. 27 or l ess. Cover i nt er i or of door sect i ons wi t h st eel sheet s

Apr i l 2019 Page 4 SECTI ON 08 36 13 of not l i ght er t han 27 gage t o compl et el y encl ose t he i nsul at i ng mat er i al .

2. 4. 1. 2 Al umi num Sect i ons

At t he Cont r act or ' s opt i on, door sect i ons may be const r uct ed of al umi num i n l i eu of st eel . Pr ovi de t he same st r uct ur al and t her mal pr oper t i es f or al umi num sect i ons as speci f i ed f or st eel sect i ons.

2. 4. 2 Tracks

Pr ovi de gal vani zed st eel t r acks not l i ght er t han 14 gage t hi ck f or 2 i nch t r acks and not l i ght er t han 12 gage t hi ck f or 3 i nch t r acks. Pr ovi de gal vani zed st eel ver t i cal t r acks wi t h cont i nuous gal vani zed st eel angl e not l i ght er t han 13 gage f or i nst al l at i on t o wal l s. I ncl i ne ver t i cal t r ack t hr ough use of adj ust abl e br acket s t o obt ai n a weat her t i ght c l osur e at j ambs. Rei nf or ce hor i zont al t r ack wi t h gal vani zed st eel angl e; suppor t f r om t r ack cei l i ng const r uct i on wi t h gal vani zed st eel angl e and cr oss br aci ng t o pr ovi de a r i gi d i nst al l at i on.

2. 4. 3 Hardware

Pr ovi de hi nges, br acket s, r ol l er s, l ocki ng devi ces, and ot her har dwar e r equi r ed f or compl et e i nst al l at i on. I nst al l r ol l er br acket s and hi nges wi t h 14 gage gal vani zed st eel . Pr ovi de r ol l er s wi t h bal l bear i ngs and case- har dened r aces. Pr ovi de r ei nf or ci ng on door s wher e r ol l er hi nges ar e connect ed. Pr ovi de a posi t i ve l ocki ng devi ce and cyl i nder l ock wi t h t wo keys on manual l y oper at ed door s.

2. 4. 4 Counterbalancing

Count er bal ance door s wi t h an oi l - t emper ed, hel i cal - wound t or si onal spr i ng mount ed on a st eel shaf t . Pr ovi de adj ust abl e spr i ng t ensi on, connect spr i ng t o door s wi t h cabl e t hr ough cabl e dr ums. Pr ovi de cabl e saf et y f act or of at l east 5 t o 1.

2. 5 MANUAL OPERATORS

2. 5. 1 Pushup Oper at or s

Pr ovi de l i f t i ng handl es on bot h s i des of door . Do not exceed t he l esser of 10 per cent of t he door wei ght or 25 pounds f or t he maxi mum l i f t i ng f or ce of r equi r ed t o oper at e t he door . Pr ovi de pul l down st r aps or r opes at bot t om of door s over 7 f eet hi gh.

2. 5. 2 Chai n Hoi st Oper at or s

Pr ovi de a gal vani zed, endl ess chai n oper at i ng over a spr ocket . Ext end chai n t o wi t hi n 4 f eet of t he f l oor and mount on i nsi de of bui l di ng.

Obt ai n r educt i on by use of r ol l er chai n and spr ocket dr i ve or gear i ng.

Pr ovi de chai n c l eat and pi n f or secur i ng oper at or chai n. Al l ow f or f ut ur e i nst al l at i on of power oper at or s t o chai n hoi st oper at or . Do not exceed t he maxi mum l i f t i ng f or ce of 35 pounds r equi r ed t o oper at e t he door .

2. 6 ELECTRI C OPERATORS

2. 6. 1 Oper at or Feat ur es

Oper at or s shal l be l abel ed and l i s t ed t o t he r equi r ement s of UL 325.

Pr ovi de oper at or s of t he dr awbar t ype or s i de mount ( j ack shaf t ) t ype as

Apr i l 2019 Page 5 SECTI ON 08 36 13 r ecommended by t he manuf act ur er . I ncl ude oper at or s wi t h el ect r i c mot or , machi ne- cut r educt i on gear s, st eel chai n and spr ocket s, magnet i c br ake, br acket s, pushbut t on cont r ol s, l i mi t swi t ches, magnet i c r ever si ng cont act or , a manual chai n hoi st oper at or f or emer gency use, and ot her accessor i es necessar y f or oper at i on. Desi gn el ect r i c oper at or so mot or may be r emoved wi t hout di st ur bi ng t he l i mi t swi t ch t i mi ng and wi t hout af f ect i ng t he manual oper at or . Pr ovi de t he oper at or wi t h s l i ppi ng cl ut ch coupl i ng t o pr event st al l i ng t he mot or . Pr ovi de a c l ut ch cont r ol l ed emer gency manual oper at or so t hat i t may be engaged and di sengaged f r om t he f l oor ; do not af f ect l i mi t swi t ch t i mi ng by oper at i on. The manual oper at or i s not r equi r ed i f door can be manual - pushup oper at ed wi t h a f or ce not t o exceed 25 pounds. Pr ovi de an el ect r i cal or mechani cal devi ce t hat di sconnect s t he mot or f r om t he oper at i ng mechani sm when t he manual oper at or i s engaged.

2. 6. 2 Motors

NEMA MG 1, hi gh- st ar t i ng t or que, r ever si bl e t ype wi t h suf f i c i ent hor sepower and t or que out put t o move t he door i n ei t her di r ect i on f r om any posi t i on. Pr ovi de a mot or t o pr oduce a door t r avel speed of not l ess t han 8 i nch or mor e t han one f oot per second wi t hout exceedi ng t he r at ed capaci t y. Mot or s shal l be oper at e on cur r ent of t he char act er i st i cs i ndi cat ed at not mor e t han 3600 r pm. Si ngl e- phase mot or s shal l not have commut at i on or mor e t han one st ar t i ng cont act . Pr ovi de mot or encl osur es wi t h dr i p- pr oof t ype or NEMA TENV t ype.

2. 6. 3 Controls

Pr ovi de a mot or f or each door wi t h an encl osed, acr oss- t he- l i ne t ype, magnet i c r ever si ng cont act or , t her mal over l oad and under vol t age pr ot ect i on, sol enoi d- oper at ed br ake, l i mi t swi t ches, and cont r ol swi t ches. Locat e cont r ol swi t ches at l east 5 f eet above t he f l oor so t he oper at or wi l l have compl et e v i s i bi l i t y of t he door at al l t i mes. Pr ovi de cont r ol equi pment t o conf or m t o NEMA I CS 1 and NEMA I CS 2. Pr ovi de cont r ol encl osur es wi t h NEMA I CS 6, Type 12 or Type 4, except t hat cont act or encl osur es may be Type 1. Pr ovi de a t hr ee- but t on t ype cont r ol swi t ch st at i ons wi t h but t ons mar ked " OPEN, " " CLOSE, " and " STOP. " The " OPEN" and " STOP" but t ons shal l r equi r e onl y moment ar y pr essur e t o oper at e. The " CLOSE" but t on shal l r equi r e const ant pr essur e t o mai nt ai n t he c l osi ng mot i on of t he door . I f t he door i s i n mot i on and t he " STOP" but t on i s pr essed or t he " CLOSE" but t on r el eased, t he door shal l st op i nst ant l y and r emai n i n t he st op posi t i on; f r om t he st op posi t i on, t he door may be oper at ed i n ei t her di r ect i on by t he " OPEN" or " CLOSE" but t on.

Pushbut t ons shal l be f ul l - guar ded t o pr event acci dent al oper at i on.

Pr ovi de l i mi t swi t ches t o aut omat i cal l y st op door s at t he f ul l y open and cl osed posi t i ons. Li mi t swi t ch posi t i ons shal l be r eadi l y adj ust abl e.

2. 6. 4 Ent r apment Pr ot ect i on Devi ces

Ent r apment pr ot ect i on devi cesshal l be pr ovi ded f or el ect r i cal l y- oper at ed door s i n accor dance wi t h UL 325. These devi ces shal l i mmedi at el y st op and r ever se t he door i n i t s c l osi ng t r avel upon sensi ng an obst r uct i on i n t he door openi ng or upon f ai l ur e of t he devi ce or any component of t he cont r ol syst em. Any moment ar y door - c l osi ng ci r cui t shal l be aut omat i cal l y l ocked out and t he door shal l be oper abl e manual l y or wi t h const ant pr essur e cont r ol s unt i l t he f ai l ur e or damage has been cor r ect ed. No ent r apment pr ot ect i on devi ce shal l be used as a l i mi t swi t ch, unl ess i t s f unct i on i s speci f i cal l y i nt ended t o do so.

Apr i l 2019 Page 6 SECTI ON 08 36 13

2. 6. 5 Cont r ol Tr ansf or mer s

NEMA ST 20. Pr ovi de t r ansf or mer s i n power c i r cui t s as necessar y t o r educe t he vol t age on t he cont r ol c i r cui t s t o 120 vol t s or l ess.

2. 6. 6 El ect r i cal Component s

NFPA 70. Fur ni sh manual or aut omat i c cont r ol and saf et y devi ces, i ncl udi ng ext r a f l exi bl e Type SO cabl e and spr i ng- l oaded aut omat i c t akeup r eel or equi val ent devi ce, f or oper at i on of t he door s. Condui t wi r i ng and mount i ng of cont r ol s ar e speci f i ed i n t he cor r espondi ng el ect r i cal speci f i cat i on sect i on.

2. 6. 7 Hazar dous Locat i ons

Conf or m t o NFPA 70 I n addi t i on t o meet i ng ot her r equi r ement s speci f i ed, el ect r i cal mat er i al s, equi pment , and devi ces f or i nst al l at i on i n hazar dous l ocat i ons and be speci f i cal l y appr oved by Under wr i t er s Labor at or i es or by an i ndependent t est i ng agency usi ng equi val ent st andar ds, f or t he par t i cul ar chemi cal gr oup and t he cl ass and di v i s i on of hazar dous l ocat i on involved.

2. 7 WEATHER SEALS AND SENSI NG EDGES

Pr ovi de ext er i or door s wi t h weat her pr oof j oi nt s bet ween sect i ons by means of t ongue- and- gr oove j oi nt s, r abbet t ed j oi nt s, shi pl ap j oi nt s, or wool pi l e, v i nyl or r ubber weat her st r i ppi ng; a r ubber , or v i nyl adj ust abl e weat her st r i p at t he t op and j ambs; and a compr essi bl e neopr ene or r ubber weat her seal at t ached t o t he bot t om of t he door . On ext er i or door s t hat ar e el ect r i cal l y oper at ed, wher e a sensi ng edge i s empl oyed, t he bot t om seal shal l be combi nat i on compr essi bl e weat her seal and sensi ng edge f or st oppi ng and r ever si ng door movement . On i nt er i or door s t hat ar e el ect r i cal l y oper at ed , wher e a sensi ng edge i s empl oyed, t he bot t om seal shal l be a compr essi bl e t ype of sensi ng edge f or st oppi ng and r ever si ng door movement .

2. 8 FINISHES

Hot - di p gal vani ze conceal ed met al sur f aces and t r acks i n accor dance wi t h ASTM A123/ A123M. Hot - di p gal vani zed and ot her f er r ous met al sur f aces, except r ol l er s and l ock component s, whi ch ar e gal vani zed or pl at ed shop primed.

2. 8. 1 Gal vani zed and Shop Pr i med

Pr ovi de a z i nc coat i ng on speci f i ed sur f aces, a phosphat e t r eat ment , and a shop pr i me coat of r ust - i nhi bi t i ve pai nt . Conf or m t o ASTM A653/ A653M f or gal vani zed coat i ng, coat i ng desi gnat i on G60, f or st eel sheet s, and ASTM A123/ A123M f or assembl ed st eel pr oduct s. The wei ght of coat i ngs f or assembl ed pr oduct s shal l be as desi gnat ed i n Tabl e I of ASTM A123/ A123M f or t he c l ass of mat er i al t o be coat ed. Pr ovi de a pr i me coat especi al l y devel oped f or mat er i al s t r eat ed by phosphat es and adapt ed t o appl i cat i on by di ppi ng or spr ayi ng. Repai r damaged zi nc- coat ed sur f aces wi t h gal vani z i ng r epai r pai nt and spot pr i me. At t he Cont r act or ' s opt i on, a t wo- par t syst em i ncl udi ng bonder i z i ng, baked- on epoxy pr i mer , and baked- on enamel t opcoat may be appl i ed i n l i eu of pr i me coat speci f i ed.

Apr i l 2019 Page 7 SECTI ON 08 36 13

2. 8. 2 Aluminum

Pr ovi de a c l ear anodi zed f i ni sh t o al umi num sur f aces i n accor dance wi t h AA- M10- C22- A41 cont ai ned i n AA DAF45 and NAAMM AMP 500. Pr et r eat exposed sur f aces and appl y a baked- on enamel f i ni sh i n accor dance wi t h manuf act ur er ' s st andar d.

PART 3 EXECUTI ON

3. 1 INSTALLATION

NFPA 70. I nst al l door s i n accor dance wi t h appr oved shop dr awi ngs and manuf act ur er ' s wr i t t en i nst al l at i on i nst r uct i ons. Lubr i cat e and adj ust door s t o oper at e f r eel y.

Pr ovi de a weat her t i ght i nst al l at i on and f r ee f r om war p, t wi st , or di st or t i on. Adj ust and l ubr i cat e door s t o oper at e f r eel y.

Pr ovi de al l i t ems and accessor i es f or a compl et e i nst al l at i on i n ever y respect.

3. 2 ELECTRI CAL WORK

NFPA 70. Condui t , wi r i ng, and mount i ng of cont r ol s.

3. 3 TESTING

Af t er i nst al l at i on i s compl et e, oper at e door s t o demonst r at e i nst al l at i on and f unct i on of oper at or s, saf et y f eat ur es, and cont r ol s. Cor r ect deficiencies.

- - End of Sect i on - -