Plumbing
| BUILDING | LOCATION | BARCODE | TEAM INITIAL | INVENTORY DATE | SYSTEM TYPE | ASTM CODE | EQUIPMENT TYPE | EQUIPMENT DESC | MANUFACTURER | MODEL_MAKE | SERIAL NO | Quantity | SIZE_CAPACITY | UOM | GENERAL CONDITION | COMMENTS |
| 513 | Basement | DJC | 5/16/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009M2 | 137326 | 1 | 3/4 | IN | Good | (barcode note rqd, however barcode #249 was applied) | |
| 513 | Basement | SBGP000250 | DJC | 5/16/11 | Domestic water System | D304003 | Natural Gas tank type | Domestic water heater | A.O. Smith | FSG-50 | 40,000 | 1 | 50 | GA | Good |
| 407 | First floor | SBGP000248 | DJC | 5/16/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | Rheem | 81V-30D | 099113819 | 1 | 30 | GA | Good |
| 407 | First floor | SGBP000247 | DJC | 5/16/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | Rudd | PL530-2 | 1085108275 | 1 | 30 | GA | Good |
| 407 | First floor | DJC | 5/16/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909CW | 128477 | 1 | 3/4 | IN | Good |
| 597 | Upper Floor | SGBP000244 | DJC | 5/17/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Duplex pump staiton | Aurora | 894066 | 1 set (2 pumps total) | Good | |||
| 597 | Upper Floor | SGBP000246 | DJC | 5/17/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | State | P6610M5k | 1 | 6 | GA | Good | |
| 597 | Lower Floor | SGBP000242 | DJC | 5/17/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Duplex pump staiton | GE | 5K1230 | PEP1711 | 1 set (2 pumps total) | Good | ||
| 597 | Lower Floor | SGBP000214 | DJC | 5/17/11 | Mechanical room drainage | Submersible sump lift station | Duplex pump staiton | ABS | 1 set (2 pumps total) | Good | |||||
| 597 | Lower Floor | DJC | 5/17/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 155022 | 1 | 1 | IN | Good | |
| 597 | Lower Floor | DJC | 5/17/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 237479 | 1 | 3/4" | IN | Good | |
| 597 | Lower Floor | SGBP000241 | DJC | 5/17/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | A.O. Smith | ELJF-20 | ME90-0037250 | 1 | 20 gallon | GA | Good |
| 515 | Lower Mech Rm Floor | SGBP000240 | DJC | 5/17/11 | Mechanical room drainage | D202001 | Submersible sump lift station | Duplex pump staiton | Aurora | 8800702-1 | 1 1/2 | 1 set (2 pumps total) | Good | ||
| 515 | Main Floor | SGBP000239 | DJC | 5/17/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | A.O. Smith | KEN-30 | MG88 005-0574 | 1 | 30 gallon | GA | Good |
| 515 | Main Floor | SGBP000243 | DJC | 5/17/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | 1/2" | 1 | Good | |||
| 515 | Lower Mech Rm Floor | DJC | 5/17/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909CW | 15925 | 1 | 3/4" | IN | Good |
| 501 | Lower level (mens toilet) | SGBP000238 | DJC | 5/18/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Simplex | Proflo | 1 | Good | |||||
| 501 | Lower level (main lift station mech rm) | SGBP000236 | DJC | 5/18/11 | Sanitary Sewer System | D203004 | Sewage lift station | Duplex pump staiton | Flygt | 3152-181-2694 | 1 set (2 pumps total) | 436 gpm ea. | GPM | Good | (Also Pumps bldg#501 and 522) | |
| 501 | Lower level (main lift station mech rm) | SGBP000237 | DJC | 5/18/11 | Mechanical room drainage | D202001 | Submersible sump lift station | Simplex | Hydromatic | 5K-3AA | 20 gpm | 1 | 20 gpm | GPM | Good | |
| 501 | Lower level (men/womens toilet) | SGBP000235 | DJC | 5/18/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Simplex | Proflo | 1 | Good | |||||
| 501 | Lower level (rm 412) | SGBP000234 | DJC | 5/18/11 | Sprinkler drain lift station | D202001 | Submersible sump lift station | Duplex pump staiton | Proflo | 1 set (2 pumps total) | Good | |||||
| 501 | Lower level (rm 477) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | A05932 | 1 | 1" | IN | Good | ||
| 501 | Upper level (mech rm) | SGBP000233 | DJC | 5/18/11 | Domestic water System | D304003 | Steam tank type | Domestic water heater | Old Dominion | 1 | 650 gallon | GA | Good | |||
| 501 | Upper level (mech rm) | SGBP000232 | DJC | 5/18/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | Little Red | HV-A40 | 1 | 1" | IN | Good | |
| 501 | Upper level (mech rm) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | A01944 | 1 | 1/2" | IN | Good | ||
| 501 | Upper level (mech rm) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 14496 | 1 | 1 1/2" | IN | Good | ||
| 501 | Upper level (mech rm) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 127072 | 1 | 3/4" | IN | Good | ||
| 501 | Upper level (mech rm) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | 1 | 1 1/4" | IN | Good | |||
| 501 | Upper level (rm1328) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 1 | 1/2" | IN | Good | ||||
| 501 | Upper level (rm1328) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | 1 | 3/4" | IN | Good | |||
| 501 | Middle level (rm M462) | DJC | 5/18/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | 350220 | 1 | 1/2" | IN | Good | ||
| 501 | Upper level (under mezz) | SGBP000231 | DJC | 5/18/11 | Mechanical room drainage | D202001 | Submersible sump lift station | Simplex | Grindex | 1 | 1 1/2" | IN | Good | |||
| 501 | Middle level (rm 1832) | SGBP000230 | DJC | 5/18/11 | Condensate drainage | D202001 | Submersible sump lift station | Simplex | Hydromatic | OSP-33 | 1 | 1 1/2" | IN | Good | ||
| 501 | Middle level (molhole) | SGBP000229 | DJC | 5/18/11 | Ground water drainage | D202001 | Submersible sump lift station | Simplex | Hydromatic | OSP-33 | 1 | 1 1/2" | IN | Good |
591 Main level SGBP000228 DJC 5/18/11 Domestic water System D304003 Electric tank type Domestic water heater A.O. Smith ELJ-6 ME87 1 6 gallon GA Good
519 Lower Floor DJC 5/18/11 Domestic water System D202003 RPZ backflow preventer Watts 009 27715 2 3" IN Good
| 500 | Boiler Room | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Conbraco | 40207A2 | CY112 | 1 | 1 1/2" | IN | Good | ||
| 500 | Boiler Room | SGBP000220 | DJC | 5/19/11 | Domestic water System | D304003 | Steam tank type | Domestic water heater | Old Dominion | 650 | 1 | 650 gallon | GA | Good | ||
| 500 | Boiler Room | SGBP000246 | DJC | 5/19/11 | Domestic water System | D304003 | Steam tank type | Domestic water heater | Old Dominion | 650 | 1 | 650 gallon | GA | Good | ||
| 500 | Boiler Room | SGBP000227 | DJC | 5/19/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | 102206 | lttle red | 1 | 1" | IN | Good | |
| 500 | Boiler Room | SGBP000226 | DJC | 5/19/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | 102206 | lttle red | 1 | 1" | IN | Good | |
| 500 | Boiler Room | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009M | 88971 | 1 | 2" | IN | Good | ||
| 500 | Boiler Room | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 128137 | 1 | 2" | IN | Good | ||
| 500 | Boiler Room | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 128893 | 1 | 3/4" | IN | Good | ||
| 500 | Boiler Room | SGBP000225 | DJC | 5/19/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Duplex pump staiton | Aurora | 150 gpm | 1 set (2 pumps total) | 150 gpm | GPM | Good | ||
| 500 | Boiler Room | SGBP000224 | DJC | 5/19/11 | Mechanical room drainage | D202001 | Submersible sump lift station | Simplex | Proflo | 1 | 1 1/2" | IN | Old | |||
| 500 | Boiler Room | SGBP000223 | DJC | 5/19/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | B11 | HVBNFI | 1 | Good | |||
| 500 | Boiler Room | SGBP000222 | DJC | 5/19/11 | Domestic water System | D304003 | Steam tank type | Domestic water heater | Old Dominion | 1 | 200 gallon | GA | Good | |||
| 500 | Tunnel | SGBP000221 | DJC | 5/19/11 | Tunnel Drainage | D202001 | Submersible sump lift station | Simplex | Proflo | 1 | 1 1/2" | IN | Good | |||
| 500 | Tunnel | SGBP000219 | DJC | 5/19/11 | Tunnel Drainage | D202001 | Submersible sump lift station | Simplex | Proflo | 1 | 1 1/2" | IN | Good | |||
| 500 | Tunnel | (no access) | DJC | 5/19/11 | Tunnel Drainage | D202001 | Submersible sump lift station | Simplex | Proflo | 1 | 1 1/2" | IN | Good | |||
| 500 | BH Mech Room | SGBP000218 | DJC | 5/19/11 | Domestic water System | D304003 | Steam tank type | Domestic water heater | Old Dominion | 63-1295 | 63-162 | 1 | 423 gallon | GA | Good | |
| 500 | BH Mech Room | SGBP000216 | DJC | 5/19/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | HV | J98 | 1 | 1" | IN | Good | |
| 500 | BH Mech Room | SGBP000215 | DJC | 5/19/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Duplex pump staiton | Smith loveless | 150 gpm | PE-860 | 1 set (2 pumps total) | 150 gpm | GPM | Old | |
| 500 | BH Mech Room | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 388M | 1 | 3/4" | IN | Good | ||
| 500 | First floor | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009qt | A21623 | 1 | 1/2" | IN | Good | ||
| 500 | First floor | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 34080 | 1 | 1 1/4" | IN | Good | Cafeteria at kitchen hood | |
| 500 | First floor | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 1 | 3/4" | IN | Good | Wing 1 G | ||
| 500 | First floor (café Closet) | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 009 | 55124 | 1 | 1/2" | IN | Good | Cafeteria Closet | |
| 500 | Third Floor (3J) | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909CW | 116207 | 1 | 1" | IN | Good | ||
| 500 | Basement | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 568620 | 1 | 3/4" | IN | Good | Room BJ15 | |
| 500 | First floor (café ) | SGBP000213 | DJC | 5/19/11 | Kitchen Waste | D203004 | Kitchen Grease Trap | Surface mounted Grease Trap | PDI | 15 gpm | 30 lbs grease | 1 | 3" | IN | Good | Kitchen |
| 500 | Front lawn | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Watts | 909 | 156834 | 1 | 3" | IN | Good | Irrigation |
| 522 | First floor | SGBP000210 | DJC | 5/19/11 | Domestic water System | D304003 | Electric tank type | Domestic water heater | A.O. Smith | DSE-40 | BC5051078793 | 1 | 40 gallon | GA | Good |
| 522 | First floor | SGBP000209 | DJC | 5/19/11 | Domestic water System | D304003 | In-line Re-circ pump | Domestic water htg recirc pump | Bell and Gossett | 1 | Good | ||||
| 522 | First floor | SGBP000201 | DJC | 5/19/11 | Sanitary Sewer System | D203004 | Submersible sewage lift station | Duplex pump staiton | Weil | 2 | Good | ||||
| 522 | First floor | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Febco | 860 | H02407 | 1 | 1/2" | IN | Good | |
| 522 | Second floor | DJC | 5/19/11 | Domestic water System | D202003 | RPZ | backflow preventer | Febco | 860 | H01962 | 1 | 3/4" | IN | Good |