Appendix_B_Plumbing_Equipment.xlsx

XLSX spreadsheet 238 KB Posted

Attached to
Mx & Repair Bldg 500 Federal contract opportunity
Solicitation number
FA4600-16-R-0012
Issued by
Department of the Air Force Air Combat Command

About this file

Appendix B - Plumbing Equipment

View the file

Other files for this federal contract opportunity

Other files attached to Mx & Repair Bldg 500, newest first.
File Type Posted
Answers-Vendor_Questions_4_Final.pdf PDF
Answers-Vendor_Questions_3_Final.pdf PDF
FA4600-16-R-0012-0002_Amendment_2.pdf PDF
Att_20-Performance_Work_Statement_6-13-17.pdf PDF
Answers-Vendor_Questions_2_Final.pdf PDF
Answers-Vendor_Questions_Final.pdf PDF
FA4600-16-R-0012-0001_Amendment_1.pdf PDF
Appendices_E_F_G_H_I_J_K_L.pdf PDF
Appendix_D.pdf PDF
Appendix_B_Electrical_Equipment.xlsx XLSX spreadsheet
Appendix_M.pdf PDF
Appendix_B_HVAC_Equipment.xlsx XLSX spreadsheet
Appendix_B_Pegasus_Supplemental.XLSX XLSX spreadsheet
Appendix_B_MISC.xlsx XLSX spreadsheet
Appendix_B_Fire_Protection_Equipment.xlsx XLSX spreadsheet
Appendices_A_B_C.pdf PDF
Att_6_NDA_Agreement_(new).pdf PDF
Att_11_OFCCP_EEOC_Clrnc_Req.doc DOC document
Att_21_List_of_Required_Reports.pdf PDF
FA4600-16-R-0012.pdf PDF
Att_18_Local_Instructions.pdf PDF
Att_10_Wg_Dtrmntn.pdf PDF
Att_22_Work_Order_historical_data.xlsx XLSX spreadsheet
Att_13__PPQ_Cover_Letter.docx DOCX document
Att_5_SF328.pdf PDF
Att_20-Performance_Work_Statement.pdf PDF
Att_8_DODM_5200.01,_Vol._4.pdf PDF
Att_7_DODI_8582.01.pdf PDF
Att_19_EAL.xlsx XLSX spreadsheet
Att_9_Contractor_Validation.xls XLS spreadsheet
Att_4_CoI.pdf PDF
Att_12_Pst_Perf_Info_(PPI)_Doc.doc DOC document
Att_14_Pst_Prsnt_Perf_Qstnr.docx DOCX document
Att_6_NDA_Agreement.pdf PDF
Att_1_Maps_drwngs_eqpt_list.pdf PDF
Att_15_Pst_Perf_Trkng_Rec.docx DOCX document
Att_2_Pricing_Model.xlsx XLSX spreadsheet
Att_16_Sub-KT_Tm_Consent_Ltr.docx DOCX document
Att_17_Client_Auth_Letter.docx DOCX document
Att_3_QASP.pdf PDF
Show all 40

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Plumbing

BUILDINGLOCATIONBARCODETEAM INITIALINVENTORY DATESYSTEM TYPEASTM CODEEQUIPMENT TYPEEQUIPMENT DESCMANUFACTURERMODEL_MAKESERIAL NOQuantitySIZE_CAPACITYUOMGENERAL CONDITIONCOMMENTS
513BasementDJC5/16/11Domestic water SystemD202003RPZbackflow preventerWatts009M213732613/4INGood(barcode note rqd, however barcode #249 was applied)
513BasementSBGP000250DJC5/16/11Domestic water SystemD304003Natural Gas tank typeDomestic water heaterA.O. SmithFSG-5040,000150GAGood
407First floorSBGP000248DJC5/16/11Domestic water SystemD304003Electric tank typeDomestic water heaterRheem81V-30D099113819130GAGood
407First floorSGBP000247DJC5/16/11Domestic water SystemD304003Electric tank typeDomestic water heaterRuddPL530-21085108275130GAGood
407First floorDJC5/16/11Domestic water SystemD202003RPZbackflow preventerWatts909CW12847713/4INGood
597Upper FloorSGBP000244DJC5/17/11Sanitary Sewer SystemD203004Submersible sewage lift stationDuplex pump staitonAurora8940661 set (2 pumps total)Good
597Upper FloorSGBP000246DJC5/17/11Domestic water SystemD304003Electric tank typeDomestic water heaterStateP6610M5k16GAGood
597Lower FloorSGBP000242DJC5/17/11Sanitary Sewer SystemD203004Submersible sewage lift stationDuplex pump staitonGE5K1230PEP17111 set (2 pumps total)Good
597Lower FloorSGBP000214DJC5/17/11Mechanical room drainageSubmersible sump lift stationDuplex pump staitonABS1 set (2 pumps total)Good
597Lower FloorDJC5/17/11Domestic water SystemD202003RPZbackflow preventerWatts90915502211INGood
597Lower FloorDJC5/17/11Domestic water SystemD202003RPZbackflow preventerWatts90923747913/4"INGood
597Lower FloorSGBP000241DJC5/17/11Domestic water SystemD304003Electric tank typeDomestic water heaterA.O. SmithELJF-20ME90-0037250120 gallonGAGood
515Lower Mech Rm FloorSGBP000240DJC5/17/11Mechanical room drainageD202001Submersible sump lift stationDuplex pump staitonAurora8800702-11 1/21 set (2 pumps total)Good
515Main FloorSGBP000239DJC5/17/11Domestic water SystemD304003Electric tank typeDomestic water heaterA.O. SmithKEN-30MG88 005-0574130 gallonGAGood
515Main FloorSGBP000243DJC5/17/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and Gossett1/2"1Good
515Lower Mech Rm FloorDJC5/17/11Domestic water SystemD202003RPZbackflow preventerWatts909CW1592513/4"INGood
501Lower level (mens toilet)SGBP000238DJC5/18/11Sanitary Sewer SystemD203004Submersible sewage lift stationSimplexProflo1Good
501Lower level (main lift station mech rm)SGBP000236DJC5/18/11Sanitary Sewer SystemD203004Sewage lift stationDuplex pump staitonFlygt3152-181-26941 set (2 pumps total)436 gpm ea.GPMGood(Also Pumps bldg#501 and 522)
501Lower level (main lift station mech rm)SGBP000237DJC5/18/11Mechanical room drainageD202001Submersible sump lift stationSimplexHydromatic5K-3AA20 gpm120 gpmGPMGood
501Lower level (men/womens toilet)SGBP000235DJC5/18/11Sanitary Sewer SystemD203004Submersible sewage lift stationSimplexProflo1Good
501Lower level (rm 412)SGBP000234DJC5/18/11Sprinkler drain lift stationD202001Submersible sump lift stationDuplex pump staitonProflo1 set (2 pumps total)Good
501Lower level (rm 477)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts009A0593211"INGood
501Upper level (mech rm)SGBP000233DJC5/18/11Domestic water SystemD304003Steam tank typeDomestic water heaterOld Dominion1650 gallonGAGood
501Upper level (mech rm)SGBP000232DJC5/18/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and GossettLittle RedHV-A4011"INGood
501Upper level (mech rm)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts009A0194411/2"INGood
501Upper level (mech rm)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts9091449611 1/2"INGood
501Upper level (mech rm)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts90912707213/4"INGood
501Upper level (mech rm)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts00911 1/4"INGood
501Upper level (rm1328)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts11/2"INGood
501Upper level (rm1328)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts00913/4"INGood
501Middle level (rm M462)DJC5/18/11Domestic water SystemD202003RPZbackflow preventerWatts00935022011/2"INGood
501Upper level (under mezz)SGBP000231DJC5/18/11Mechanical room drainageD202001Submersible sump lift stationSimplexGrindex11 1/2"INGood
501Middle level (rm 1832)SGBP000230DJC5/18/11Condensate drainageD202001Submersible sump lift stationSimplexHydromaticOSP-3311 1/2"INGood
501Middle level (molhole)SGBP000229DJC5/18/11Ground water drainageD202001Submersible sump lift stationSimplexHydromaticOSP-3311 1/2"INGood

591 Main level SGBP000228 DJC 5/18/11 Domestic water System D304003 Electric tank type Domestic water heater A.O. Smith ELJ-6 ME87 1 6 gallon GA Good

519 Lower Floor DJC 5/18/11 Domestic water System D202003 RPZ backflow preventer Watts 009 27715 2 3" IN Good

500Boiler RoomDJC5/19/11Domestic water SystemD202003RPZbackflow preventerConbraco40207A2CY11211 1/2"INGood
500Boiler RoomSGBP000220DJC5/19/11Domestic water SystemD304003Steam tank typeDomestic water heaterOld Dominion6501650 gallonGAGood
500Boiler RoomSGBP000246DJC5/19/11Domestic water SystemD304003Steam tank typeDomestic water heaterOld Dominion6501650 gallonGAGood
500Boiler RoomSGBP000227DJC5/19/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and Gossett102206lttle red11"INGood
500Boiler RoomSGBP000226DJC5/19/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and Gossett102206lttle red11"INGood
500Boiler RoomDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts009M8897112"INGood
500Boiler RoomDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts90912813712"INGood
500Boiler RoomDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts90912889313/4"INGood
500Boiler RoomSGBP000225DJC5/19/11Sanitary Sewer SystemD203004Submersible sewage lift stationDuplex pump staitonAurora150 gpm1 set (2 pumps total)150 gpmGPMGood
500Boiler RoomSGBP000224DJC5/19/11Mechanical room drainageD202001Submersible sump lift stationSimplexProflo11 1/2"INOld
500Boiler RoomSGBP000223DJC5/19/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and GossettB11HVBNFI1Good
500Boiler RoomSGBP000222DJC5/19/11Domestic water SystemD304003Steam tank typeDomestic water heaterOld Dominion1200 gallonGAGood
500TunnelSGBP000221DJC5/19/11Tunnel DrainageD202001Submersible sump lift stationSimplexProflo11 1/2"INGood
500TunnelSGBP000219DJC5/19/11Tunnel DrainageD202001Submersible sump lift stationSimplexProflo11 1/2"INGood
500Tunnel(no access)DJC5/19/11Tunnel DrainageD202001Submersible sump lift stationSimplexProflo11 1/2"INGood
500BH Mech RoomSGBP000218DJC5/19/11Domestic water SystemD304003Steam tank typeDomestic water heaterOld Dominion63-129563-1621423 gallonGAGood
500BH Mech RoomSGBP000216DJC5/19/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and GossettHVJ9811"INGood
500BH Mech RoomSGBP000215DJC5/19/11Sanitary Sewer SystemD203004Submersible sewage lift stationDuplex pump staitonSmith loveless150 gpmPE-8601 set (2 pumps total)150 gpmGPMOld
500BH Mech RoomDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts909388M13/4"INGood
500First floorDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts009qtA2162311/2"INGood
500First floorDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts9093408011 1/4"INGoodCafeteria at kitchen hood
500First floorDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts90913/4"INGoodWing 1 G
500First floor (café Closet)DJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts0095512411/2"INGoodCafeteria Closet
500Third Floor (3J)DJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts909CW11620711"INGood
500BasementDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts90956862013/4"INGoodRoom BJ15
500First floor (café )SGBP000213DJC5/19/11Kitchen WasteD203004Kitchen Grease TrapSurface mounted Grease TrapPDI15 gpm30 lbs grease13"INGoodKitchen
500Front lawnDJC5/19/11Domestic water SystemD202003RPZbackflow preventerWatts90915683413"INGoodIrrigation
522First floorSGBP000210DJC5/19/11Domestic water SystemD304003Electric tank typeDomestic water heaterA.O. SmithDSE-40BC5051078793140 gallonGAGood
522First floorSGBP000209DJC5/19/11Domestic water SystemD304003In-line Re-circ pumpDomestic water htg recirc pumpBell and Gossett1Good
522First floorSGBP000201DJC5/19/11Sanitary Sewer SystemD203004Submersible sewage lift stationDuplex pump staitonWeil2Good
522First floorDJC5/19/11Domestic water SystemD202003RPZbackflow preventerFebco860H0240711/2"INGood
522Second floorDJC5/19/11Domestic water SystemD202003RPZbackflow preventerFebco860H0196213/4"INGood

File details come from the government source that posted it. Updated .