Dwgs Bid Documents-part 3-1 REV.pdf
PDF 16 MB Posted
- Attached to
- EHRM Infrastructure Upgrades Construction Sioux Falls VAMC Federal contract opportunity
- Solicitation number
- 36C77622R0049
About this file
This document outlines a federal contract opportunity for construction services. The Sioux Falls VA Medical Center is soliciting proposals for infrastructure upgrades needed to support its Electronic Health Record Modernization project. Work will include building a new server room on the medical center's roof and touch several departments. The construction period is approximately 450 calendar days from notice to proceed. The contract is set aside for Service-Disabled Veteran-Owned Small Businesses and has an estimated value between $20-50 million. Proposals are due in response to solicitation number 36C77622R0049. All questions must be submitted in writing to the issuing office by the specified deadline.
View the file
Other files for this federal contract opportunity
Show all 44
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D
N C
D
D
D
D
D
D D D D D D D
DDDDDD
D
D
D D D D D D D D D D D D
DDD
C R
C R
TV
CR
CC
C
TV TV TV
C R
CR CR
C R
C R
C
C R
C R
CR
AC
D D
D
C R
CR
N C
WAP
2D/1
2T/2
4D/1
4D/1
2D/0
WAP
2D/2
WAP
2D/02D/22D/2 1V/0
1D/1
2D/2 1V/02D/2 1V/0
COAX 1/0 COAX 1/0 COAX 1/0
2D/12D/1
6D/21D/12D/2
2D/2
2D/1
1D/11D/1
2D/1
2D
2D/1
2T/1
2T/0
3D/3
2D/1
COAX
3D/2
3D
3D3D/33D/1
2D/1
3D
2D
3D/32D
3D/11D
3D/13D/1
D
WAP
2D/1
4D/1
1D
2D/1 2D/1
2D/1
2D
2D/1
2D/2
2D
W
2D/1 1D/0
D
3D/0
?D/1
WAP
2D/1
XRAY 2D/1
2D 2D/1
2D
2D/1
XRAY
COAX 1/0
4D/0 3D/0 1D/1 4D/0
2D/1 2D/1
XRAY
XRAY
2D/1
4D/1
XRAY
4D/0
4D/4
2D/2 2V/1
2D/2
2D/03D/2
2D/1
2D/12D/1
2D/1
WAP
3D/1
D
4D/12D/1
2D/1
2D/1 4D 2D/1
2D
6D/12D/1
WAP 4D/2
2D/1
2D/11D/0
WAP
2D/1
2D/1
1D/1
2D/1
2D/1
1D/1
4D/4
3D/0
3D/02D/1 1V/0
3D/0 3D/0 1V/0
3D/0 1V/0 2D/1 1V/0
2D/1 2D/2
1D/0
3D/2
3D/2
1D/1
1D/1 1V/02D/1 1V/0
4D/1 1V/0
2D/2 1V/0
2D/1 1V/0 2D/1 1V/0
1V/0
2D/1 1V/0
3D/2 1V/0
2D/1 1V/0 2D/2 1V/0
4D/0 1V/0
1V/0
2D/2 1V/0
2D/1 1V/0
2D/1 1V/0 2D/1 1V/02D/1 1V/0
2D/1 2V/0
2D/0 1V/0
2D/1 1V/0
2D/1 1V/0
4D/2 1V/0
2D/1 1V/1 2D/1 1V/1 2D/1 1V/0
1D
2D/1 1V/0 2D/1 1V/0 2D/0 1V/0 2D/1 1V/0 2D/1 1V/1
2D/1 1V/0
2D/1 1V/1
2D/1 1V/0 2D/1 1V/0 2D/2 1V/1
2D/1 1V/0
2D/2 2V/0 2D/1 1V/0 2D/0 1V/0
2D/2 1V/0
2D/1 1V/0
2D
2D/1 1V/1 2D/1 1V/0
6D/6
2D/1 1V/02D/1 1V/0
ED301-05-E
ED301-05-E
ED301-05-E
"x
4"
"x
4"
"x
4"
4" 4" 4" 4"
12"x4"
8" x2
8"x2" 8"x2"
8" x2
8" x2
8"x2" 8"x2"
8"x2"
12"x4"
12"x4"
12"x4"
12"x4"
"x
4"
12"x4"12"x4"
12"x4"
12"x4"
12"x4"
12"x4"
8"x2"
SWITCHGEAR #1
G1
D
N1
E
E
EXISTING GENERATOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:1
P M
ED101-05-E
GROUND LEVEL ELECTRICAL
DEMOLITION PLAN - BUILDING 5 -
AREA E
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/8" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION PLAN - BUILDING 5 - AREA E
1:96
8' 12'
SHEET NOTES:
1. REFER TO PHASING NOTES LOCATED ON SHEET EE500 FOR INFORMATION
REGARDING PHASING OF DEMOLITION AND INSTALLATION OF NEW GENERATOR
SWITCHBOARD AND DEMOLISHED GENERATOR.
Revisions: Date:
CR
AC
C R
EFACP AC AC
NCC
E
E
E
W 24"x4"
R
D
D
D
E E E
E
EE
E
E
PA
E
D D
D
E E
E
4" 4" 4" 4"
EEEE
PA
DW FBNCC
D
DDE
E
W E
EE 2
ACAC
E
D
D
NCC
E
FB
D
TW
4"
4"
4"
4" 4" 4"
E
E
E
E E
BAS
BAS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:1
P M
ED301-05-E
GROUND LEVEL ELECTRICAL
DEMOLITION - BUILDING 5 -
ENLARGED ROOMS - AREA E
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/2" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION - BUILDING 5 - AREA E - ROOM B23
1/2" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION - BUILDING 5 - AREA E - ROOM B59
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT. REMOVE ALL UNUSED CABLING AT THE COMPLETION OF THE PROJECT.
1. ROOM B59
EXISTING CABLE COUNT
DATA (CAT6): 48
DATA (CAT5): 264
VIDEO: 1
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 4
CABLE RELOCATION COUNT
DATA (CAT6): -24 TO ROOM A27
DATA (CAT6): -24 TO ROOM B23
DATA (CAT5): -132 TO ROOM A27
DATA (CAT5): -132 TO ROOM B23
VIDEO: -1 TO ROOM A27
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: -2 TO ROOM A27
COMMERCIAL WIRELESS: -2 TO ROOM B23
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
2. ROOM B23
EXISTING CABLE COUNT
DATA (CAT6): 195
DATA (CAT5): 22
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): +24 FROM ROOM B59
DATA (CAT6): +56 FROM ROOM F58
DATA (CAT5): +132 FROM ROOM B59
DATA (CAT5): +184 FROM ROOM F58
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: +2 FROM ROOM B59
EXISTING CABLE TO REMAIN
DATA (CAT6): 195
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 613
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 2
3. ROOM F58
EXISTING CABLE COUNT
DATA (CAT6): 56
DATA (CAT5): 184
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): -56 TO ROOM B23
DATA (CAT5): -184 TO ROOM B23
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
SHEET NOTES:
1. EXISTING TELEPHONE WALL FIELD TO BE DEMOLISHED. NEW COPPER
BACKBONE TO BE PROVIDED ON PATCH PANELS IN TELECOMMUNICATIONS
RACK. REFER TO CABLING NOTES AND NEW WORK PLANS FOR ADDITIONAL
REQUIREMENTS.
2. EXISTING FIBER ENCLOSURE TO BE DEMOLISHED. NEW FIBER BACKBONE TO BE
TERMINATED IN NEW TELECOMMUNICATIONS RACK. REFER TO CABLING NOTES
AND NEW WORK PLANS FOR ADDITIONAL REQUIREMENTS.
1:24
2' 3'
1:24
2' 3'
Revisions: Date:
1/2" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION - BUILDING 5 - AREA E - ROOM F58
1:24
2' 3'
N C
D
D
D
D
D
D D D D D D D
DDDDDD
D
D
D D D D D D D D D D D D
DDD
C R
C R
TV
CR
CC
C
TV TV TV
C R
CR CR
C R
C R
C
C R
C R
CR
AC
D D
D
C R
CR
N C
T
T
.5E.7E .9E 1E 2E 3E 4E 5E 6E 7E 8E 9E
EE
FE
GE
HE
IE
JE
3D3D3D
1D 6D1D2D
2D
1D
W
1D
3D
4D
4D
4D
2D
2D
2D2D
2D 2D
2D
2D
2D
2D
4D
1D
3D
4D 2D
2D
2D 2D 2D
2D
2D
4D
1D
2D 2D
2D
2D
2D
2D
2D
2D
1D
1D
1D
3D
3D
3D 3D 3D
3D 3D
2D
3D
2D
3D2D
3D 1D
2D 2D
3D
3D
3D
3D
3D 3D 3D 3D 3D 3D 3D 3D 3D 3D 3D 3D 3D
3D3D
3D 3D
2D
3D
3D
3D
3D
3D4D
3D3D
3D
5D
1D
4D
3D
3D
3D
1D
1D
4D
3D
3D 3D
5D
3D 3D 3D 3D
3D
3D 4D
4D 3D 3D 2D
1D
3D
2D
2D
2D
2D
3D
2D
1D 1D
2D 2D
2D 2D
2D
2D
4D
4D4D2D2D4D1D3D4D
T301-05-E
6D
2D
6D2D 4D
2D
2D
2D
2D3D2D2D
1D 3D
1D
2D
2D
2D
2D
2D
4D
ATS-A SIDE
8"x2"
"x
4"
12"x4"
8" x2
8"x2"
8" x2
8" x2
8"x2"
8"x2"
8" x2
4"4"4"4"
12"x4"
12"x4"
"x
4"
12"x4"12"x4"
12"x4"
12"x4"
12"x4"
12"x4"12"x4"
12"x4"
12"x4"
12"x4"
UPS A1
A1
A SIDE
T-B1B1
SSIU-B23
B23-A B23-B
2"
4"
2"
2"
2"
2"
2" 2"
T301-05-E
WAP
WAP
WAP
WAP
1D 1D 1D
XRAYXRAY
XRAY
XRAY
WAP
XRAY
1D
WAP
4D
"x
4"
12"x4"
12"x4"
8"x2"
4" 4" 4" 4"
"x
4"
18"x4" 18"x4"
SWITCHGEAR #1
E
1 2
N1
E
F28
STAIR 9
Space F07A
STAIR 8
Space
F05
ELEV EQUIP
B15
STOR
B41
EXAM
B43C
EXAM
B43
OFFICE
B43B
OFFICE
B44
EXAM
B09
OFFICE
B08
EXAM
B06
COSULT
B04
EXAM
B50
TOILET
B52
EXAM
B82
OFFICE
B89A
OFFICE
B84
OFFICE
B86
OFFICE
B83
ADMIN
B87A
OFFICE
B98
AGENT CASHIER
B54
OFFICE
B55
OFFICE
B57
OFFICE
B58
ELEC
B34
EXAM
B17
EXAM
B39
TRIAGE
B56
OFFICE
B72A
MENTAL HEALTH
B69C
CLEAN UTIL
B71
TRIAGE
B74
GEN EXAM 2
B72
GEN EXAM 1
B73A
TOILET
B73
WOMANS HEALTH
B69
PHYSICIAN WORK
B89D
BOOTH 2
B89B
CORRIDOR
B89E
BOOTH 3
B46
EXAM
B53
EMS
B51
EXAM
B45
OFFICE
B42
WORK ROOM
B40
OFFICE
B49
EXAM
B47
OFFICE
B30
EMS
B28
LOCKER
B37A
TRIAGE
B37
TRIAGE
B38A
ON-CALLB38B
TLT./ SHOWER
B62
PROCEDURE
B48
EXAM
F29
EXAM
F27
EXAM
F26
EXAM
F25
EXAM
F24
NURSE OFFICE
F23
PROCEDURE
F22
EXAM
F21
EXAM
F20
EXAM
F11
TOILET
F10
STAFF TOILET
F12
STOR
F15
ELEC
F58
TELECOM
F14
EXAM
F59
OFFICE
F60
EXAM
F13
EXAM
F16
EXAM
F53
Room
F52
EXAM
F17
NURSE OFFICE
F51
EXAM
F50
STOR
F49
TOILET
F18
EXAM
F19
DICTATION
F48
HAC
F36
OFFICE
F34
TOILET
F33
LOCKER
F32
DICTATION
F35
LOUNGE
F38
EXAM
F31
EXAM
F30
CLEAN STOR
BREAK ROOM
B59
TELE
B02
EXAM
B01
EXAM
B03
OFFICEB05
SOILEDB07
PROCEDURE
B14
TOILET
B12
BREAKROOM
B18
EXAM
B19
ELEC
B21
EXAM
B22
TOILET
B24
SLEEP
B26
NURSE
B27
EXAM
B29
EXAM
B332
EXAM
B33
EXAM
B69A
ELEC
B37B
STORAGE
B69B
SOILED UTILITY
B67A
DECONTAM
C21A
CORRIDOR
Space
B68
PAT SUBWAIT
B70
ED RECPT.
CHECK-IN
B36
EMERGENCY
Space
G10
WOMANS LOCKER
G09
MENS LOCKER
F07
TOILET
C24C
CORRIDOR
F09
EXAM
F08
ELEV EQUIP
F57
EXAM
F54
EXAM
F47
NURSE OFFICE
F46
EXAM
F45
SOILED
F44
EXAM
F43
EXAM
F42
EXAM
F41
EXAM
F40
EXAM
F39
NURSE OFFICE
F56
EXAM
F55
EXAM
B38
NURSE
G08
CORRIDOR
B20
Room
C25
CORRIDOR
C27
CORRIDOR
C28
Room
C29
CORRIDOR
B35
OFFICE
C24
CORRIDOR
B31
STOR
F04
WAITING
F37A
OFFICE
F37
OFFICE
C26
CORRIDOR
F37E
Room
C34
CORRIDOR
C31
CORRIDOR
C33
CORRIDOR
Space
B66A
GENERATOR
B66
ELEC
B89C
BOOTH 1
C20
CORRIFOR
C24A
CORRIDOR
C03-1
CORRIDOR-1
B23
TELECOMM
B76
WAITING
B67
AMBULANCE BAY
C23
ENTRY
Space
8"x2"
G1
(MAIN)
(DISTRIBUTION)
(DISTRIBUTION)
(TIE)
SSOU-B66ABSSOU-B66AA
SSIU-B66AB
SSIU-B66AA
WR
24"
INSTALL GREEN INSULATED
GROUND WIRE WITH
LIGHTING, RECEPTACLE AND
EQUIPMENT BRANCH CIRCUITS.
INSTALL INDIVIDUAL (DEDICATED)
NEUTRAL CONDUCTORS FOR
EACH 120V OR 277V PHASE
CONDUCTOR SERVED FROM A
SINGLE POLE CIRCUIT BREAKER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/2 /2
:3
:2
P M
TN101-05-E
GROUND LEVEL LOW VOLTAGE
PLAN - BUILDING 5 - AREA E
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
11/29/2021 KSB NMT16090
11/29/2021
1/8" = 1'-0"
GROUND LEVEL LOW VOLTAGE FLOOR PLAN - BUILDING 5 - AREA E
SHEET NOTES:
1:96
8' 12'
1. PROVIDE NEW 1200A, 3-POLE, GFPE CIRCUIT BREAKER IN EXISTING SWITCHGEAR #1
TO FEED NEW A SIDE SWITCHBOARD. SWITCHGEAR #1 IS A SQUARE D QED2, 65KAIC
SWITCHBOARD.
2. PROVIDE THREE NEW 400A, 3-POLE, GFPE CIRCUIT BREAKERS IN EXISTING
SWITCHGEAR #1 TO FEED UPS BYPASS CIRCUITS. SWITCHGEAR #1 IS A SQUARE D
QED2, 65KAIC SWITCHBOARD.
3. REFER TO PHASING NOTES LOCATED ON SHEET EE500 FOR INFORMATION
REGARDING PHASING OF DEMOLITION AND INSTALLATION OF NEW GENERATOR
SWITCHBOARD AND DEMOLISHED GENERATOR.
4. EQUIPMENT INDICATED SHALL BE FOR FUTURE (NOT IN CONTRACT). CONTRACTOR
SHALL PROVIDE SPACE TO ACCOMMODATE SECTIONS IN THE FUTURE.
5. PROVIDE #3/0 COPPER BONDING CONDUCTOR FROM GROUND BAR TO GROUNDING
ELECTRODE CONDUCTOR IN SWITCHGEAR #1.
6. PROVIDE EATON 93PM 200-4 OR EQUIVALENT 200 KW UPS WITH SIDECAR
WRAPAROUND BYPASS CABINET, AND MINIMUM 10 MINUTES OF BATTERY RUNTIME.
PROVIDE AS 480V, 3-PHASE INPUT AND 208Y/120V, 3-PHASE, 4 WIRE OUTPUT WITH K13
RATED TRANSFORMER.
7. ABOVE CEILING SPACE IS EXTREMELY LIMITED IN THIS AREA. UTILIZE J-HOOKS OR
OTHER SIMILAR SUPPORT METHODS FOR CABLING IN THIS AREA.
8. SAW CUT FLOOR SLAB AS REQUIRED TO ACCOMMODATE GENERATOR FEED
CONDUITS FROM BUILDING 50. PROVIDE (5) 4" CONDUITS TO NEW SWITCHBOARD
MAIN SECTION FOR CONDUCTORS INSTALLED UNDER THIS CONTRACT.
9. REFER TO CIVIL PLANS FOR DUCTBANK CONTINUATION.
10. PROVIDE (5) 4" CONDUITS FOR FUTURE SWITCHBOARD MAIN-TIE-MAIN EXPANSION.
STUB CONDUITS INTO BUILDING AND CAP FOR FUTURE USE.
11. PROVIDE (2) 4" CONDUITS, ONE FOR ATS/GENERATOR CONTROLS CABING AND ONE
SPARE. PROVIDE 12 STRAND SINGLE MODE FIBER OPTIC CABLE FROM RELOCATED
ATS CONTROLLER TO BUILDING 50 ATS/GENERATOR CONTROLLER.
12. CIRCUIT TO NEAREST AVAILABLE RECEPTACLE CIRCUIT.
CC
ID IE
T301-05-E a
B23-BB23-A
B23-A-1,3,5
B23-B-1,3,5
B23-A-7,9,11
B23-B-7,9,11
B23-A-13,15,17
B23-B-13,15,17
NCC
PA
FACP
PA
13 - b c
13 - d
AC AC
E EE
E
E
EE
E
E
E E
E
E E
E
MOTION W
L21-20 L21-20
L21-20L21-20 L21-20L21-20
C5
B23-B-31
B23-A-37
B23-B-33
SIDE CABLE
MANAGEMENT
(TYP)
RACK 2 ELECTRONIC EQUIPMENT
NOTES:
1. COORDINATE FINAL RACK LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
2. PROVIDE COMPONENTS NOT LISTED "BY OWNER".
3. SEE SPECIFICATION FOR ADDITIONAL RACK COMPONENTS.
4. COORDINATE EXACT RACK LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
5. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL DEVICE COUNT AND QUANTITY OF PATCH
PANELS, SWITCHES, FIBER ENCLOSURES, AND CABLE MANAGEMENT REQUIRED.
7. COORDINATE INSTALLATIONS WITH OWNER'S IS/IT REPRESENTATIVE.
1U 48 STRAND OM4 FIBER OPTIC DISTRIBUTION PANEL
1U RACK BONDING BUSBAR
1U 24 STRAND OS1 FIBER OPTIC DISTRIBUTION PANEL
1U BLANKING PANEL
1U BLANKING PANEL
SPACE FOR
OWNER EQUIPMENT
1U RACK BONDING BUSBAR
RACK 3 DISTRIBUTION
1U 24 PORT VOICE BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
1U RACK BONDING BUSBAR
SPACE FOR NON-IT
SYSTEM
ELECTRONICS
RACK 1 NON-IT SYSTEMS
CHANNEL RACK CHANNEL RACK CHANNEL RACK
1U BLANKING PANEL
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
12U SPACE FOR FUTURE12U SPACE FOR FUTURE
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
2U CATV PATCH PANEL
1U CABLE MANAGEMENT
2U COMMERCIAL WIRELESS PATCH PANEL
1U CABLE MANAGEMENT
1U CABLE MANAGEMENT
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
1U NETBOTZ 750 MONITOR SYSTEM
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
IE
IE
T301-05-E a
B23-BB23-A
PA
PA
13 - b c
13 - d
2"
2"
4" 4" 4" 4"
12"x4"
"x
4"
E
"x
4"
E
E E E E
E
I1
I1
I1
I1
B23-B-35
B23-A-39
SSIU-B23
MEC
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
IE
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:3
:5
P M
T301-05-E
ENLARGED ROOM B23 VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/2" = 1'-0"
ENLARGED ROOM B23 - BUILDING 05 - POWER & DATA
NO SCALE
RACK ELEVATION - ROOM B23
1/4" = 1'-0"
13 - a
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
ROOM B23
EXISTING CABLE COUNT
DATA (CAT6): 195
DATA (CAT5): 22
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): +24 FROM ROOM B59
DATA (CAT6): +56 FROM ROOM F58
DATA (CAT5): +132 FROM ROOM B59
DATA (CAT5): +184 FROM ROOM F58
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: +2 FROM ROOM B59
EXISTING CABLE TO REMAIN
DATA (CAT6): 195
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 196
DATA(CAT6A): 418
VIDEO: 8
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 2
1/2" = 1'-0"
ENLARGED ROOM B23 - BUILDING 05 - LIGHTING & CABLE TRAY
1/4" = 1'-0"
13 - b 1/4" = 1'-0"
13 - c
1/4" = 1'-0"
13 - d
1:24
2' 3'
1:24
2' 3'
Revisions: Date:
SHEET NOTES:
1. PROVIDE NEW BONDING CONDUCTOR AS SHOWN ON TELECOMMUNICATIONS
ROUTING SCHEMATIC ON SHEET EE600.
HAUSER
TRACY J.
10206
RE
G
IS
TE
RE
DP
ROFESSIONAL ENGINEER
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/2 /2
:3
:3
P M
EE401-05-E
PANEL SCHEDULES - BUILDING 5 -
GROUND LEVEL - AREA E
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
11/29/2021 KSB NMT16090
11/29/2021
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT BREAKER WITH LOCKING
PROVISIONS / 'R' - PROVIDE CIRCUIT BREAKER WITH RED MARKING
OPTIONS:
51 A
SPARE CAPACITY:
51 %
FEEDER AVAILABLE:
EQUIPMENT AMPS: 100 A
CONSIDER 125% DEMAND: 21973 A
PWR-NC 17295 VA 78.91% 13648 VA DEMAND CURRENT: 49 A
MTR 2975 VA 124.00% 3689 VA DEMAND LOAD: 17578 VA
REC 180 VA 100.00% 180 VA CONNECTED CURRENT: 57 A
LTG 50 VA 125.00% 62 VA CONNECTED LOAD: 20500 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
TOTAL AMPS: 64 A 63 A 48 A
TOTAL LOAD: 7433 VA 7302 VA 5765 VA
41 42
39 LTG TELECOMM B23 20 A 1 50 VA 40
37 REC TELECOMM B23 20 A 1 180 VA 38
35 SPARE -- 20 A 1 0 VA 36
33 SPARE -- 20 A 1 0 VA 34
31 SPARE -- 20 A 1 0 VA 32
29 0 VA 30
27 0 VA 28
SPARE -- 20 A 3
0 VA 26
23 SPARE -- 20 A 1 0 VA 24
21 1488 VA 22
SSIU-B22/SSOU-B22 30 A 2
1488... 20
17 1922 VA 18
15 1922 VA 16
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 14
11 1922 VA 12
9 1922 VA 10
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 8
5 1922 VA 6
3 1922 VA 4
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 2
C... CIRCUIT DESCRIPTION OPT RATI... POL... A B C POL... RATI... OPT CIRCUIT DESCRIPTION C...
NEMA ENCLOSURE: 1
MOUNTING: SURFACE AVAILABLE SCC (kA): 6.1 PANEL POLES: 42
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 1
BRANCH: CRITICAL WIRES: 4 MCB OPTIONS: NONE
SUPPLY FROM: A1 PHASES: 3 MCB/MLO RATING: 100 A
LOCATION: TELECOMM B23 VOLTS: 208/120 WYE MAINS TYPE: MCB
LIGHTING PANEL: B23-A
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT BREAKER WITH LOCKING
PROVISIONS / 'R' - PROVIDE CIRCUIT BREAKER WITH RED MARKING
OPTIONS:
61 A
SPARE CAPACITY:
60 %
FEEDER AVAILABLE:
EQUIPMENT AMPS: 100 A
CONSIDER 125% DEMAND: 17587 A
DEMAND CURRENT: 39 A
PWR-NC 17295 VA 78.91% 13648 VA DEMAND LOAD: 14069 VA
REC 360 VA 100.00% 360 VA CONNECTED CURRENT: 49 A
LTG 50 VA 125.00% 62 VA CONNECTED LOAD: 17705 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
TOTAL AMPS: 50 A 50 A 48 A
TOTAL LOAD: 5945 VA 5945 VA 5815 VA
41 42
39 40
37 38
35 LTG TELECOMM B23 20 A 1 50 VA 36
33 REC TELECOMM B23 20 A 1 180 VA 34
31 REC TELECOMM B23 20 A 1 180 VA 32
29 SPARE -- 20 A 1 0 VA 30
27 SPARE -- 20 A 1 0 VA 28
25 SPARE -- 20 A 1 0 VA 26
23 0 VA 24
21 0 VA 22
SPARE -- 20 A 3
0 VA 20
17 1922 VA 18
15 1922 VA 16
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 14
11 1922 VA 12
9 1922 VA 10
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 8
5 1922 VA 6
3 1922 VA 4
PWR-C TELECOMM B22 - RACK
RECEPTACLE
20 A 3
1922... 2
C... CIRCUIT DESCRIPTION OPT RATI... POL... A B C POL... RATI... OPT CIRCUIT DESCRIPTION C...
NEMA ENCLOSURE: 1
MOUNTING: SURFACE AVAILABLE SCC (kA): 4.1 PANEL POLES: 42
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 1
BRANCH: NORMAL WIRES: 4 MCB OPTIONS: NONE
SUPPLY FROM: B1 PHASES: 3 MCB/MLO RATING: 100 A
LOCATION: TELECOMM B23 VOLTS: 208/120 WYE MAINS TYPE: NCB
LIGHTING PANEL: B23-B
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT
BREAKER WITH LOCKING PROVISIONS
OPTIONS:
164 A
SPARE CAPACITY:
EQUIPMENT AMPS: 1200 A
CONSIDER 125% DEMAND: 1076593 A
DEMAND CURRENT: 1036 A
DEMAND LOAD: 861275 VA
MTR 121716 VA 111.30% 135476 VA CONNECTED CURRENT: 1019 A
Spare 725799 VA 100.00% 725799 VA CONNECTED LOAD: 847515 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
Total A: 1019 A
Total VA: 847515 VA
10 SPARE -- 3 400 A 0 VA
9 SPARE -- 3 100 A 0 VA
8 SPARE -- 3 80 A 0 VA
7 UPS A2 -- 3 400 A 241933 VA
6 UPS A1 -- 3 400 A 241933 VA
5 MCR UPS A -- 3 400 A 241933 VA
4 ACCU-2 3 15 A 5820 VA
3 ACCU-1 3 15 A 5820 VA
2 CRAC-2 MAIN SERVER ROOM 201 3 100 A 55038 VA
1 CRAC-1 MAIN SERVER ROOM 201 3 100 A 55038 VA
CKT CIRCUIT DESCRIPTION OPT POLES RATING LOAD CIRCUIT REMARKS
AVAILABLE SCC (kA): 54
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 1
BRANCH: CRITICAL WIRES: 4 MCB OPTIONS: GFA, ERMS
SUPPLY FROM: ATS-A SIDE PHASES: 3 MCB/MLO RATING: 1200 A
LOCATION: GENERATOR B66A VOLTS: 480/277 WYE MAINS TYPE: MCB
A SIDE
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT
BREAKER WITH LOCKING PROVISIONS
OPTIONS:
237 A
SPARE CAPACITY:
EQUIPMENT AMPS: 600 A
CONSIDER 125% DEMAND: 163373 A
PWR-NC 178720 VA 52.80% 94360 VA DEMAND CURRENT: 363 A
MTR 29215 VA 102.44% 29929 VA DEMAND LOAD: 130699 VA
REC 5760 VA 100.00% 5760 VA CONNECTED CURRENT: 595 A
LTG 520 VA 125.00% 650 VA CONNECTED LOAD: 214215 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
Total A: 595 A
Total VA: 214215 VA
15 SSIU-B66AA/SSOU-B66AA 2 30 A 2975 VA
14 SPARE -- 3 100 A 0 VA
13 SPARE -- 3 100 A 0 VA
12 SPARE -- 3 100 A 0 VA
11 SPARE -- 3 100 A 0 VA
10 433-A 3 100 A 21040 VA
9 UPS3 (330C-A) 3 100 A 13920 VA
8 UPS2 (226C-A) 3 100 A 13922 VA
7 1026A-A 3 100 A 24024 VA
6 111-A 3 100 A 21040 VA
5 1014-A 3 100 A 18068 VA
4 CRE2.1 (1002-A) 3 100 A 13970 VA
3 A27-A 3 200 A 38539 VA
2 H1-A 3 100 A 26220 VA
1 B23-A 3 100 A 20500 VA
CKT CIRCUIT DESCRIPTION OPT POLES RATING Load CIRCUIT REMARKS
AVAILABLE SCC (kA): 15.1
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 1
BRANCH: CRITICAL WIRES: 4 MCB OPTIONS: NONE
SUPPLY FROM: PHASES: 3 MCB/MLO RATING: 600 A
LOCATION: GENERATOR B66A VOLTS: 208/120 WYE MAINS TYPE: MCB
A1
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT
BREAKER WITH LOCKING PROVISIONS
OPTIONS:
162 A
SPARE CAPACITY:
EQUIPMENT AMPS: 500 A
CONSIDER 125% DEMAND: 152271 A
PWR-NC 178720 VA 52.80% 94360 VA DEMAND CURRENT: 338 A
MTR 16095 VA 104.44% 16809 VA DEMAND LOAD: 121817 VA
REC 9720 VA 100.00% 9720 VA CONNECTED CURRENT: 570 A
LTG 743 VA 125.00% 928 VA CONNECTED LOAD: 205278 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
Total A: 570 A
Total VA: 205278 VA
15 SSIU-B66AA/SSOU-B66AA 2 30 A 2975 VA
14 SPARE -- 3 100 A 0 VA
13 SPARE -- 3 100 A 0 VA
12 SPARE -- 3 100 A 0 VA
11 SPARE -- 3 100 A 0 VA
10 433-B 3 100 A 17885 VA
9 330C-B 3 100 A 12070 VA
8 226C-B 3 100 A 12432 VA
7 1026A-B 3 100 A 26586 VA
6 111-B 3 100 A 18065 VA
5 1014-B 3 100 A 20863 VA
4 1002-B 3 100 A 11940 VA
3 A27-B 3 200 A 38719 VA
2 H1-B 3 100 A 26040 VA
1 B23-B 3 100 A 17705 VA
CKT CIRCUIT DESCRIPTION OPT POLES RATING Load CIRCUIT REMARKS
AVAILABLE SCC (kA): 7
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 1
BRANCH: NORMAL WIRES: 4 MCB OPTIONS: NONE
SUPPLY FROM: T-B1 PHASES: 3 MCB/MLO RATING: 500 A
LOCATION: GENERATOR B66A VOLTS: 208/120 WYE MAINS TYPE: MCB
B1
A. PANEL AIC (INTERRUPTING) RATING SHALL BE MINIMUM 120% OF THE AVAILABLE SCC (SHORT CIRCUIT CURRENT).
GENERAL REMARKS:
CIRCUIT BREAKER OPTIONS SUFFIX: 'S' OR 'ST' - PROVIDE SHUNT TRIP CIRCUIT BREAKER / 'G' OR 'GFCI' - PROVIDE GFCI CIRCUIT BREAKER / 'GFP' - PROVIDE GFP CIRCUIT BREAKER / 'ERMS' - ENERGY REDUCING MAINTENANCE SWITCH / 'ZSI' - ZONE SELECTIVE INTERLOCKING / 'L' - PROVIDE CIRCUIT
BREAKER WITH LOCKING PROVISIONS
OPTIONS:
564 A
SPARE CAPACITY:
EQUIPMENT AMPS: 1600 A
CONSIDER 125% DEMAND: 1076593 A
DEMAND CURRENT: 1036 A
DEMAND LOAD: 861275 VA
MTR 121716 VA 111.30% 135476 VA CONNECTED CURRENT: 1019 A
Spare 725799 VA 100.00% 725799 VA CONNECTED LOAD: 847515 VA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS
Total A: 1019 A
Total VA: 847515 VA
5 TIE -- 3 1600 A 0 VA GFA, ERMS
4 ATS-2 -- 3 400 A 0 VA GFA
3 ATS-7 -- 3 250 A 0 VA GFA
2 ATS-UPS -- 3 400 A 0 VA GFA
1 ATS-A SIDE 3 1200 A 847515 VA GFA, ERMS
CKT CIRCUIT DESCRIPTION OPT POLES RATING LOAD CIRCUIT REMARKS
AVAILABLE SCC (kA): 17.7
SERVICE RATED: No INTEGRAL SPD: Yes SECTIONS: 4
BRANCH: GENERATOR WIRES: 4 MCB OPTIONS: GFA, ERMS
SUPPLY FROM: NORMAL PHASES: 3 MCB/MLO RATING: 1600 A
LOCATION: GENERATOR B66A VOLTS: 480/277 WYE MAINS TYPE: MCB
G1
T
SSIU-H1A
3/4" CD
G01A
STAIR 10
B79B
TOILET
B67A
DECONTAM
B78
EXAM
B76A
TOILET
B79
EXAM
B79A
EXAM
G24A
STERILIZER
G22
STERILE INST
G33A
STORAGE
G27
OR 4
G05
Room
G42
Room
G36
ON CALL
G35
ELEC
G32
SOILED
G07
OFFICE
G10B
SHOWER
G13
CLEAN
G14
SOILED
G15
Room G09B
SHOWER
G16
Room
G16A
MED GAS
G10
WOMANS LOCKER
G09
MENS LOCKER
G12
STORAGE
G11
CORRIDOR
G02B
VESTIBULE
G04
Room
G03
TELECOMM
G29
STORAGE
G31
EQUIP
G30
MED GAS
G34
EMS
G18A
ANTE ROOM
G21
OR 3
G33
SUB STERILE
G23
OR 2
G24
SUB STERILE
G18
ISOLATION
G19
TOILET
G20
PRE OP
G20A
MECHANICAL
G40
ELECTRICAL
G41
ELECTRICAL
C40
CORRIDOR
G08
CORRIDOR
G02
CORRIDOR
G02A
NURSE
G06
Room
G37B
DICTATION\
G37A
DICTATION
G37
BREAK
G25
OR 1
G24B
VENDER
G26
CLEAN CORE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H17
STERILE STORAGE
G17-1
Room-1
C42
CORRIDOR
C41
CORRIDOR
C43
CORRIDOR
C44
CORRIDOR
G01
ELEVATOR LOBBY
B76
EXAM
Space
Space
SSIU-H1B
SHERMAN
ERIC G.
10229
R E G
IS
T E R
ED
PR
OFESSIONAL
E N G
IN
E E R
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
07/06/2021
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:5
:1
P M
MP101-05-F
GROUND LEVEL PIPING PLAN -
BUILDING - 5 - AREA F
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 EGS PHV16090
1/8" = 1'-0"1
GROUND LEVEL PIPING PLAN - BUILDING 5 - AREA F
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
SHEET NOTES:
1. ROUTE CONDENSATE TO SERVICE SINK IN EMS G34.
GENERAL NOTES:
1:96
8' 12'
NC
D
D
D
D
D
D
NC
C
C
C
C
C
C
T
2D
2D 3D/1
3D/1
2D/02D/0
1MON/1
2D/1
3/D/1
2D/01PM/12D/1
3D/2
D
WAP
WAP
WAP
3D/0
1D/1
4D/1
2D/0
3D/2
3D/1
1D/0
1D/1
1D/1
WAP
WAP
WAP
WAP
WAP
WAP WAP
WAP
1D/0
3D/1
3D/2 3D/2
1D/0
3D/2
1D/0
3D/2
4D/3 1D/1
TM
1D/01D/01D/0
TM
1D/02D/11D/0
1D/01D/0 1D/0
TM
1D/0 1D/01D/0
1D/0 1D/1 1D/0
TM
TM
1D/02D/11D/0
4D/0
TM
1D/01D/11D/0
1D/1
2D/2 1D/0
TM
1D/0
1D/0
1D/0
1D/1
1D/0 TM
1D/1
1D/0
1D/0
1D/1
3D/2 2D/0
1D/0
1D/0
3D/2
1D/1
1D/0 1D/1
2D/1
3D/2
2D/0
1D/1
2D/0
2D/0
1D/0
1T/11T/1
1D/1
2D/1
2D/1
3D/0
3D/0
4D/1
2D/0
2D/0
2D/0
3D/0
3D/03D/0
1D/0 1D/1
1D/1
2D/1 1D/1
1D/1
4D/0
3D/0 3D/0
3D/0
1D/1
2D/0
2D/0
1D/0
4D/0
1T/1
2D/1
3D/0
3D/0
2D/1
1D/1
3D/0 2D/0
2D/0
3D/0 3D/0
3D/0
4D/0
4D/0
3D/0
1D
3D
3D
ED301-05-F
WAP
2D/0
2D/1
3D/13D/1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:1
P M
ED101-05-F
GROUND LEVEL ELECTRICAL
DEMOLITION PLAN - BUILDING 5 -
AREA F
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/8" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION PLAN - BUILDING 5 - AREA F
1:96
E
ACNCC
FAPS
BAS
PA
E
PA
EE
E
D
D
E
12"x2"
TW
W
D
E
E
E
E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:2
P M
ED301-05-F
GROUND LEVEL ELECTRICAL
DEMOLITION - BUILDING 5 -
ENLARGED ROOMS - AREA F
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090Revisions: Date:
1/2" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION - BUILDING 5 - AREA F - ROOM G03
1:24
2' 3'
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT. REMOVE ALL UNUSED CABLING AT THE COMPLETION OF THE PROJECT.
1. ROOM G03
EXISTING CABLE COUNT
DATA (CAT6): 336
DATA (CAT5): 0
VIDEO: 0
PATIENT MONITORING: 8
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): -336 TO ROOM H1
DATA (CAT5): 0
VIDEO: 0
PATIENT MONITORING: -8 TO ROOM H1
COMMERCIAL WIRELESS: 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
SHEET NOTES:
1. EXISTING TELEPHONE WALL FIELD TO BE DEMOLISHED. NEW COPPER
BACKBONE TO BE PROVIDED ON PATCH PANELS IN TELECOMMUNICATIONS
RACK. REFER TO CABLING NOTES AND NEW WORK PLANS FOR ADDITIONAL
REQUIREMENTS.
NC
D
D
D
D
D
D
NC
C
C
C
C
C
C
22.1
27.928
L.2
.5E .7E .9E 1E 2E
C.1C.A
B.AB.1
G.1
F.1
A.1
AEE
AE
AAE
BE
CEDEEE
2D
2D
1MON
2D
3D
1D
3D
3D
2D
2D
4D
2D 1D 2D
3D
1D
TM1D1D1D
TM1D2D1D
TM1D1D1D
1D1D1D
TM1D1D1D
TM1D2D1D
4D
TM1D1D1D
2D
1D
1D
1D
1D
1D
TM
1D
1D
1D
1D
1D
TM
2D3D
1D
3D
3D
4D
3D
1D
3D
1D
3D
1D
2D
2D
3D 3D 3D
3D
1D
1D
2D2D
2D
1D1D
2D
3D
2D
1D1D
1D
3D
1D
1D
3D
1D1D
1D
3D
3D
1D
3D
3D 3D
2D
2D
1D1D
1D
4D
1D
2D 1D
1D
3D
3D
1D
3D
3D 3D
2D
3D
1D
3D
1D
3D
3D 3D
1D
2D
2D
2D
4D
2D
2D
2D
4D
1D
4D
4D
2D
2D
T301-05-G
H1-BH1-A
T301-05-G
WAP
WAP
WAP
WAP
3D
3D
WAP
WAP
WAP
WAP
WAP
"x
4"
4" 4" 4" 4" 4" 4" 4"
2"
2"
SSIU-H1A
2"
B79B
TOILET
B78
EXAM
B76A
TOILET
B79
EXAM
B79A
EXAM
G24A
STERILIZER
G22
STERILE INST
G33A
STORAGE
G27
OR 4
G05
Room
G42
Room
G36
ON CALL
G35
ELEC
G32
SOILED
G07
OFFICE
G10B
SHOWER
G13
CLEAN
G14
SOILED
G09B
SHOWER
G16
Room
G16A
MED GAS
G12
STORAGE
G11
CORRIDOR
G02B
VESTIBULE
G04
Room
G03
TELECOMM
G29
STORAGE
G31
EQUIP
G30
MED GAS
G34
EMS
G18A
ANTE ROOM
G21
OR 3
G23
OR 2
G24
SUB STERILE
G18
ISOLATION
G19
TOILET
G20
PRE OP
G20A
MECHANICAL
G40
ELECTRICAL
G41
ELECTRICAL
C40
CORRIDOR
G02
CORRIDOR
G02A
NURSE
G06
Room
G37B
DICTATION\
G37A
DICTATION
G37
BREAK
G25
OR 1
G24B
VENDER
G28
STORAGE
H1
TELECOM
H18
STORAGE
H17
STERILE STORAGE
C42
CORRIDOR
C41
CORRIDOR
C43
CORRIDOR
C44
CORRIDOR
G01
ELEVATOR LOBBY
B76
EXAM
Space
Space
B79B
TOILET
B78
EXAM
B76A
TOILET
B79
EXAM
B79A
EXAM
G24A
STERILIZER
G22
STERILE INST
G33A
STORAGE
G27
OR 4
G05
Room
G42
Room
G36
ON CALL
G35
ELEC
G32
SOILED
G07
OFFICE
G10B
SHOWER
G13
CLEAN
G14
SOILED
G09B
SHOWER
G16
Room
G16A
MED GAS
G12
STORAGE
G11
CORRIDOR
G02B
VESTIBULE
G04
Room
G03
TELECOMM
G29
STORAGE
G31
EQUIP
G30
MED GAS
G34
EMS
G18A
ANTE ROOM
G21
OR 3
G23
OR 2
G24
SUB STERILE
G18
ISOLATION
G19
TOILET
G20
PRE OP
G20A
MECHANICAL
G40
ELECTRICAL
G41
ELECTRICAL
C40
CORRIDOR
G02
CORRIDOR
G02A
NURSE
G06
Room
G37B
DICTATION\
G37A
DICTATION
G37
BREAK
G25
OR 1
G24B
VENDER
G28
STORAGE
H1
TELECOM
H18
STORAGE
H17
STERILE STORAGE
C42
CORRIDOR
C41
CORRIDOR
C43
CORRIDOR
C44
CORRIDOR
G01
ELEVATOR LOBBY
B76
EXAM
Space
Space
G01A
STAIR 10
B79B
TOILET
B78
EXAM
B76A
TOILET
B79
EXAM
B79A
EXAM
G24A
STERILIZER
G22
STERILE INST
G33A
STORAGE
G27
OR 4
G05
Room
G42
Room
G36
ON CALL
G35
ELEC
G32
SOILED
G07
OFFICE
G10B
SHOWER
G13
CLEAN
G14
SOILED
G15
Room
G09B
SHOWER
G16
Room
G16A
MED GAS
G12
STORAGE
G11
CORRIDOR
G02B
VESTIBULE
G04
Room
G03
TELECOMM
G29
STORAGE
G31
EQUIP
G30
MED GAS
G34
EMS
G18A
ANTE ROOM
G21
OR 3
G33
SUB STERILE
G23
OR 2
G24
SUB STERILE
G18
ISOLATION
G19
TOILET
G20
PRE OP
G20A
MECHANICAL
G40
ELECTRICAL
G41
ELECTRICAL
C40
CORRIDOR
G02
CORRIDOR
G02A
NURSE
G06
Room
G37B
DICTATION\
G37A
DICTATION
G37
BREAK
G25
OR 1
G24B
VENDER
G26
CLEAN CORE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H17
STERILE STORAGE
G17-1
Room-1
C42
CORRIDOR
C41
CORRIDOR
C43
CORRIDOR
C44
CORRIDOR
G01
ELEVATOR LOBBY
B76
EXAM
Space
Space
B79B
TOILET
B79B
TOILET
B67A
DECONTAM
B76A
TOILET
G09B
SHOWER
G10
WOMANS LOCKER
G09
MENS LOCKER
G11
CORRIDOR
G02B
VESTIBULE
C40
CORRIDOR
G08
CORRIDOR
B76
EXAM
B76A
TOILET
G09B
SHOWER
G11
CORRIDOR
G02B
VESTIBULE
C40
CORRIDOR
B76
EXAM
WAP
WAP
WAP
INSTALL GREEN INSULATED
GROUND WIRE WITH
LIGHTING, RECEPTACLE AND
EQUIPMENT BRANCH CIRCUITS.
INSTALL INDIVIDUAL (DEDICATED)
NEUTRAL CONDUCTORS FOR
EACH 120V OR 277V PHASE
CONDUCTOR SERVED FROM A
SINGLE POLE CIRCUIT BREAKER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:3
:5
P M
TN101-05-F
GROUND LEVEL LOW VOLTAGE
PLAN - BUILDING 5 - AREA F
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/8" = 1'-0"1
GROUND LEVEL LOW VOLTAGE FLOOR PLAN - BUILDING 5 - AREA F
1:96
12x6
10x8 RA
14x12 RA
FSFS
SHERMAN
ERIC G.
10229
R E G
IS
T E R
ED
PR
OFESSIONA
L
E N G
IN
E E R
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V A
S io u x F a lls
E H
R M
/2 .0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/1
/2
:1 :5
A
M
MD101-05-G
GROUND LEVEL MECHANICAL
DEMOLITION PLAN - BUILDING 5 -
AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
02/18/2022 EGS PHV16090
02/18/2022
1/8" = 1'-0"1
GROUND LEVEL MECHANICAL DEMOLITION PLAN - BUILDING 5 - AREA G
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
SHEET NOTES:
1. DEMOLISH RETURN DUCT BACK TO MAIN AND CAP OPENING. DEMOLISH SUPPLY DUCT, VAV BOX AND
ASSOCIATED PIPING SERVING ROOM BACK TO MAIN AND CAP. DEMOLISH EXISTING THERMOSTAT.
GENERAL NOTES:
1:96
SSIU-H1A
D08
MEDS
D26
CLEAN UTILITY
D07A
NURSE WORK
D10
NURSE
D07
NURSE
H15
CLEAN
WORKROOM
G01A
STAIR 10
H13D
TOILET
H14
ANTE
H24
Room
H12D
TOILET
H16
Room H13B
SHOWER
H13C
TOILET
H12B
SHOWER
H12C
TOILET
H6
HAC
C52
STAIR
H22
HAC
H23
STROAGE
B78
EXAM
B79
EXAM
B79A
EXAM
D12
STAIR 4
G03
TELECOMM
H5
OFFICE
H7
TOILET
H4
OPEN OFFICE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H20A
CART WASH
D53A
STAIR
C51
CORRIDOR
H9
OFFICE
H10
OFFICE
H11
OFFICE
H8
BREAK ROOM
H2
CONFERENCE
H13
WOMENS LOCKER
H13A
HALWAY
H19
STEAM
STERILIZERS
H21
DECONTAM
H20
CART HOLDING
H26
SCOPE
PROCESSING
H17
STERILE STORAGE
H17A
SCOPE STAGING
H12
MENS LOCKER
H12A
Room
C43
CORRIDOR
D11
PATIENT ROOM
D12A
TOILET
D11A
TOILET
D12
PATIENT ROOM
D13
BARIATRIC
PATIENT
D14A
TOILET
D13A
TOILET
D15
IT
D21
STAFF TOILET
D20
ELECTRICAL
D19
EMS
C50
CORRIDOR
G01
ELEVATOR LOBBY
D18A
OFFICE
Space
H3
MECH
D14
BARIATRIC
PATIENT
D25
PATIENT ROOM
Space
C18
CORRIDOR
B76
EXAM
H20B
AUTO CART WASH
H25
SOILED ANTE
SHERMAN
ERIC G.
10229
R E G
IS
T E R
ED
PR
OFESSIONAL
E N G
IN
E E R
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
07/06/2021
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:5
:5
P M
MH101-05-G
GROUND LEVEL DUCTWORK PLAN -
BUILDING 5 - AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 EGS PHV16090
1/8" = 1'-0"
GROUND LEVEL DUCTWORK PLAN - BUILDING 5 - AREA G
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
GENERAL NOTES:
1:96
SSIU-H1A
3/4" CD
D08
MEDS
D26
CLEAN UTILITY
D07A
NURSE WORK
D10
NURSE
D07
NURSE
H15
CLEAN
WORKROOM
G01A
STAIR 10
H13D
TOILET
H14
ANTE
H24
Room
H12D
TOILET
H16
Room H13B
SHOWER
H13C
TOILET
H12B
SHOWER
H12C
TOILET
H6
HAC
C52
STAIR
H22
HAC
H23
STROAGE
B78
EXAM
B79
EXAM
B79A
EXAM
D12
STAIR 4
G03
TELECOMM
H5
OFFICE
H7
TOILET
H4
OPEN OFFICE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H20A
CART WASH
D53A
STAIR
C51
CORRIDOR
H9
OFFICE
H10
OFFICE
H11
OFFICE
H8
BREAK ROOM
H2
CONFERENCE
H13
WOMENS LOCKER
H13A
HALWAY
H19
STEAM
STERILIZERS
H21
DECONTAM
H20
CART HOLDING
H26
SCOPE
PROCESSING
H17
STERILE STORAGE
H17A
SCOPE STAGING
H12
MENS LOCKER
H12A
Room
C43
CORRIDOR
D11
PATIENT ROOM
D12A
TOILET
D11A
TOILET
D12
PATIENT ROOM
D13
BARIATRIC
PATIENT
D14A
TOILET
D13A
TOILET
D15
IT
D21
STAFF TOILET
D20
ELECTRICAL
D19
EMS
C50
CORRIDOR
G01
ELEVATOR LOBBY
D18A
OFFICE
Space
H3
MECH
D14
BARIATRIC
PATIENT
D25
PATIENT ROOM
Space
C18
CORRIDOR
B76
EXAM
H20B
AUTO CART WASH
H25
SOILED ANTE
SSIU-H1B
REFS AND REFL UP
TO OUTDOOR UNITS
MOUNTED ON GRADE
SHERMAN
ERIC G.
10229
R E G
IS
T E R
ED
PR
OFESSIONAL
E N G
IN
E E R
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
07/06/2021
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:5
:1
P M
MP101-05-G
GROUND LEVEL PIPING PLAN -
BUILDING - 5 - AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 EGS PHV16090
1/8" = 1'-0"
GROUND LEVEL PIPING PLAN - BUILDING 5 - AREA G
1. COVER SHEET GENERAL NOTES APPLY TO ALL SHEETS.
2. ON DEMOLITION PLANS; EXISTING MECHANICAL SYSTEMS TO BE REMOVED ARE SHOWN DASHED, EXISTING
MECHANICAL SYSTEMS TO REMAIN ARE SHOWN LIGHT LINE WEIGHT. ON ALL OTHER PLANS, NEW
MECHANICAL SYSTEMS ARE INDICATED WITH HEAVY LINE WEIGHTS.
3. UNLESS NOTED OTHERWISE, DETAILS SHOWN WITHIN THESE DOCUMENTS ARE APPLICABLE FOR ALL
PIPING, EQUIPMENT AND DUCTWORK INSTALLATIONS WHETHER OR NOT SPECIFICALLY NOTED.
4. THE OWNER AND ENGINEER ARE NOT RESPONSIBLE FOR THE CONTRACTOR'S SAFETY PRECAUTIONS OR FOR THE MEANS, METHODS, TECHNIQUES, CONSTRUCTION SEQUENCES, OR PROCEDURES REQUIRED TO
PERFORM THIS WORK.
SHEET NOTES:
1. PROVIDE NEW THERMOSTAT NEXT TO EXISTING.
GENERAL NOTES:
1:96
NC
O
D
NC
T
2D/?
2D/2 2V/0 1D/1
2D/1
2D/1
5D/3
3V/0
2D/2
2D/1
2T/0
2D/2 3D/1
2D/2
1D/1
2D/2
3D/0 9D/0
3D/3
4V/0 2D/1
4D/2
3V/0
3D/2
4D/3
PP
2T/0
WAP
2D/1 1T/1
2T/0
2D/1
3D/3
2T/0
2T/0
1D/1
1D/1
2D
2D 3D/1
3D/1
2D/02D/0
1MON/1
2D/1
3/D/1
2D/01PM/1
3D/2
WAP
WAP
V
3D/0
1D/1
4D/1
2D/2
4D/1
3D/2 3D/2
3D/2
V
2D/1
3D/2
3D/2
V
1D/1
1D
3D
3D
2D/2
2D
2D/2
WAP
ED301-05-G
J-BOX E
WAP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:2
P M
ED101-05-G
GROUND LEVEL ELECTRICAL
DEMOLITION PLAN - BUILDING 5 -
AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/8" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION PLAN - BUILDING 5 - AREA G
1:96
8' 12'
Revisions: Date:
SHEET NOTES:
1. AREA TO BE CONSTRUCTED UNDER SEPARATE PROJECT. NO RECABLING IS ANTICIPATED UNDER THIS PROJECT.
COORDINATE EXTENT OF WORK REQUIRED WITH VA.
E
J-BOX
E
TW TW
D D
FB
D
D
E
E E
E
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:2
:2
P M
ED301-05-G
GROUND LEVEL ELECTRICAL
DEMOLITION - BUILDING 5 -
ENLARGED ROOMS - AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/2" = 1'-0"
GROUND LEVEL ELECTRICAL DEMOLITION - BUILDING 5 - AREA G - ROOM D09
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE. THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE PRESENT IN THE SPACE AT THE COMPLETION OF THE
PROJECT. REMOVE ALL UNUSED CABLING AT THE COMPLETION OF THE PROJECT.
1. ROOM D09
EXISTING CABLE COUNT
DATA (CAT6): 34
DATA (CAT5): 48
VIDEO: 19
PATIENT MONITORING: 8
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): 34 TO ROOM H1
DATA (CAT5): 48
VIDEO: 19
PATIENT MONITORING: -8 TO ROOM H1
COMMERCIAL WIRELESS: 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
SHEET NOTES:
1. EXISTING TELEPHONE WALL FIELD TO BE DEMOLISHED. NEW COPPER
BACKBONE TO BE PROVIDED ON PATCH PANELS IN TELECOMMUNICATIONS
RACK. REFER TO CABLING NOTES AND NEW WORK PLANS FOR ADDITIONAL
REQUIREMENTS.
2. EXISTING FIBER ENCLOSURE TO BE DEMOLISHED. NEW FIBER BACKBONE TO BE
TERMINATED IN NEW TELECOMMUNICATIONS RACK. REFER TO CABLING NOTES
AND NEW WORK PLANS FOR ADDITIONAL REQUIREMENTS.
1:24
NC
O
D
NC
22.1
O.2
27.928
N.2M.2L.2
.9E
1E
2E
E.1
D.1IH.1C.1C.AB.AB.1G.1F.1A.1AEEAEAAEBECE
3D
9D 3D
4V
4D
2D
3D
2D
1D/1
2D
2D
2D 1D
2D
2D
2D
3D
5D
3D
2D
2D
2D 3D
2D
2D
1MON
2D
3D
3D
3D
2D
2D
1D
3D
3D
2D
1D
4D
2D
1D
4D
4D
4D
2D
3D
1D 2D
3D 1D
1D
2D
2D 2D
2D
3D
2D
PP
4D
2D
1D
3D
1D
T301-05-G
H1-BH1-A
4"
T301-05-G
WAP
WAP
3D
3D
3D
WAP
3D
3D
WAP
WAP
"x
4"
4" 4" 4" 4" 4" 4" 4"
2"
2"
2"
2"
2"
2"
SSIU-H1A
2"
H15
CLEAN
WORKROOM
H13D
TOILET
H14
ANTE
H24
Room
H12D
TOILET
H16
Room H13B
SHOWER
H13C
TOILET
H12B
SHOWER
H12C
TOILET
C52
STAIR
H22
HAC
H23
STROAGE
B78
EXAM
B79
EXAM
B79A
EXAM
D12
STAIR 4
G03
TELECOMM
H5
OFFICE
H7
TOILET
H4
OPEN OFFICE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H20A
CART WASH
C51
CORRIDOR
H9
OFFICE
H10
OFFICE
H11
OFFICE
H8
BREAK ROOM
H2
CONFERENCE
H13
WOMENS LOCKER
H13A
HALWAY
H19
STEAM
STERILIZERS
H21
DECONTAM
H20
CART HOLDING
H26
SCOPE
PROCESSING
H17
STERILE STORAGE
H17A
SCOPE STAGING
H12
MENS LOCKER
H12A
Room
C43
CORRIDOR
C50
CORRIDOR
G01
ELEVATOR LOBBY
D18A
OFFICE
Space
H3
MECH
B76
EXAM
H25
SOILED ANTE
H15
CLEAN
WORKROOM
H13D
TOILET
H14
ANTE
H24
Room
H12D
TOILET
H16
Room H13B
SHOWER
H13C
TOILET
H12B
SHOWER
H12C
TOILET
C52
STAIR
H22
HAC
H23
STROAGE
B78
EXAM
B79
EXAM
B79A
EXAM
D12
STAIR 4
G03
TELECOMM
H5
OFFICE
H7
TOILET
H4
OPEN OFFICE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H20A
CART WASH
C51
CORRIDOR
H9
OFFICE
H10
OFFICE
H11
OFFICE
H8
BREAK ROOM
H2
CONFERENCE
H13
WOMENS LOCKER
H13A
HALWAY
H19
STEAM
STERILIZERS
H21
DECONTAM
H20
CART HOLDING
H26
SCOPE
PROCESSING
H17
STERILE STORAGE
H17A
SCOPE STAGING
H12
MENS LOCKER
H12A
Room
C43
CORRIDOR
C50
CORRIDOR
G01
ELEVATOR LOBBY
D18A
OFFICE
Space
H3
MECH
B76
EXAM
H25
SOILED ANTE
H15
CLEAN
WORKROOM
G01A
STAIR 10
H13D
TOILET
H14
ANTE
H24
Room
H12D
TOILET
H16
Room H13B
SHOWER
H13C
TOILET
H12B
SHOWER
H12C
TOILET
C52
STAIR
H22
HAC
H23
STROAGE
B78
EXAM
B79
EXAM
B79A
EXAM
D12
STAIR 4
G03
TELECOMM
H5
OFFICE
H7
TOILET
H4
OPEN OFFICE
G28
STORAGE
H1
TELECOM
H18
STORAGE
H20A
CART WASH
C51
CORRIDOR
H9
OFFICE
H10
OFFICE
H11
OFFICE
H8
BREAK ROOM
H2
CONFERENCE
H13
WOMENS LOCKER
H13A
HALWAY
H19
STEAM
STERILIZERS
H21
DECONTAM
H20
CART HOLDING
H26
SCOPE
PROCESSING
H17
STERILE STORAGE
H17A
SCOPE STAGING
H12
MENS LOCKER
H12A
Room
C43
CORRIDOR
C50
CORRIDOR
G01
ELEVATOR LOBBY
D18A
OFFICE
Space
H3
MECH
B76
EXAM
H20B
AUTO CART WASH
H25
SOILED ANTE
J-BOX
D08
MEDS
D26
CLEAN UTILITY
D07A
NURSE WORK
D10
NURSE
D07
NURSE
C52
STAIR
D12
STAIR 4
D53A
STAIR
H8
BREAK ROOM
D11
PATIENT ROOM
D12A
TOILET
D11A
TOILET
D12
PATIENT ROOM
D13
BARIATRIC
PATIENT
D14A
TOILET
D13A
TOILET
D15
IT
D21
STAFF TOILET
D20
ELECTRICAL
D19
EMS
C50
CORRIDOR
D14
BARIATRIC
PATIENT
D25
PATIENT ROOM
Space
C18
CORRIDOR
H6
HAC
C52
STAIR
D12
STAIR 4
H8
BREAK ROOM
C50
CORRIDOR
B76
EXAM
B76
EXAM
4" 4"
INSTALL GREEN INSULATED
GROUND WIRE WITH
LIGHTING, RECEPTACLE AND
EQUIPMENT BRANCH CIRCUITS.
INSTALL INDIVIDUAL (DEDICATED)
NEUTRAL CONDUCTORS FOR
EACH 120V OR 277V PHASE
CONDUCTOR SERVED FROM A
SINGLE POLE CIRCUIT BREAKER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
KEYPLAN
A
B
C E
D
G
F
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:3
:0
P M
TN101-05-G
GROUND LEVEL LOW VOLTAGE
PLAN - BUILDING 5 - AREA G
VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
1/8" = 1'-0"
GROUND LEVEL LOW VOLTAGE FLOOR PLAN - BUILDING 5 - AREA G
1:96
8' 12'
Revisions: Date:
SHEET NOTES:
1. AREA TO BE CONSTRUCTED UNDER SEPARATE PROJECT. NO RECABLING IS
ANTICIPATED UNDER THIS PROJECT. COORDINATE EXTENT OF WORK REQUIRED
WITH VA.
2. TELECOMMUNICATIONS ROOM H1 TO BE CONSTRUCTED UNDER A SEPARATE
PROJECT. IF PROJECT IS NOT CONSTRUCTED, FIT OUT EXISTING ROOM IN
APPROXIMATELY SAME LOCATION AS ROOM H1 AS IDENTIFIED BY VA. ADAPT ROOM
H1 DESIGN AS REQUIRED TO FIT IN NEW ROOM.
C C
ID
SIDE CABLE
MANAGEMENT
(TYP)
RACK 2 DISTRIBUTION
NOTES:
1. COORDINATE FINAL RACK LAYOUT WITH OWNER'S IS/IT REPRESENTATIVE.
2. PROVIDE COMPONENTS NOT LISTED "BY OWNER".
3. SEE SPECIFICATION FOR ADDITIONAL RACK COMPONENTS.
4. COORDINATE EXACT RACK LOCATION WITH OWNER PRIOR TO PERMANENT INSTALLATION.
5. REFER TO NEW WORK PLAN FOR RACK LOCATIONS.
6. CONTRACTOR IS RESPONSIBLE FOR FINAL DEVICE COUNT AND QUANTITY OF PATCH
PANELS, SWITCHES, FIBER ENCLOSURES, AND CABLE MANAGEMENT REQUIRED.
7. COORDINATE INSTALLATIONS WITH OWNER'S IS/IT REPRESENTATIVE.
1U RACK BONDING BUSBAR
SPACE FOR
CABLE DISTRIBUTION
1U RACK BONDING BUSBAR
RACK 3 DISTRIBUTION
1U RACK BONDING BUSBAR
SPACE FOR NON-IT
SYSTEM
ELECTRONICS
RACK 1 NON-IT SYSTEMS
CHANNEL RACK CHANNEL RACK CHANNEL RACK
1U BLANKING PANEL
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
12U SPACE FOR FUTURE12U SPACE FOR FUTURE
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U DATA PATCH PANEL
1U CABLE MANAGEMENT
2U CATV PATCH PANEL
1U CABLE MANAGEMENT
2U PATIENT MONITORING PATCH PANEL
1U CABLE MANAGEMENT
2U PATIENT MONITORING PATCH PANEL
8U SPACE FOR FUTURE
1U CABLE MANAGEMENT
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
RACK 2 ELECTRONIC EQUIPMENT
1U 48 STRAND OM4 FIBER OPTIC DISTRIBUTION PANEL
1U RACK BONDING BUSBAR
1U 24 STRAND OS1 FIBER OPTIC DISTRIBUTION PANEL
1U BLANKING PANEL
1U BLANKING PANEL
SPACE FOR
OWNER EQUIPMENT
1U 24 PORT VOICE BACKBONE PATCH PANEL
1U CABLE MANAGEMENT
CHANNEL RACK
12U SPACE FOR FUTURE
V E
R T
IC
A
L R
A C
K P
D U
V E
R T
IC
A
L R
A C
K P
D U
1U NETBOTZ 750 MONITOR SYSTEM
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
C.1
C.A
B.A
B.1
T301-05-G
14 - d
H1-B
H1-A
2" 2" a
14 - b c
I1 I1
I1I1 ab
H1-A-27
H1-B-25 a a b b
SSIU-H1A
"x
4" 12 "x
4"
"x
4"
SSIU-H1B
MEC
C.1
C.A
B.A
B.1
T301-05-G
14 - d
H1-B
H1-A
H1-A-1,3,5
H1-B-1,3,5
H1-A-7,9,11
H1-B-7,9,11
H1-A-13,15,17
H1-B-13,15,17 a
14 - b c
H1-A-19
H1-B-19
H1-A-21
H1-B-21
H1-A-23
H1-B-23
H1-A-25
MOTION W
W
L21-20
L21-20
L21-20
L21-20
L21-20
L21-20
C5
C5
H1-A-29,31,33
L21-20
L21-20
H1-B-27,29,31
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
FIRST FLOOR - BLDG 1 & 5
1510' - 10 3/4"
GROUND LEVEL- BLDG 5
1498' - 11 3/4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY
SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
B
IM
/2
.0
V
A S io u x F a lls
E H
R M
/2
.0
V
A S io u x F a lls
E H
R M l_ S
E S
.r v t
/6
/2
:3
:0
P M
T301-05-G
ENLARGED ROOM H1 VAMC SIOUX FALLS EHRM
INFRASTRUCTURE UPGRADES
Sioux Falls, SD
438-20-910
07/06/2021 KSB NMT16090
NO SCALE
RACK ELEVATION - ROOM H1
1/4" = 1'-0"
14 - d
CABLING NOTES:
A. THE EXISTING CABLE COUNT ARE THE CABLES CURRENTLY PRESENT IN THE SPACE.
THE CABLE RELOCATION COUNT ARE THE NEW OR RELOCATED CABLES TO BE FED
FROM THE SPACE. THE FINAL CABLE COUNT ARE THE CABLES THAT WILL BE
PRESENT IN THE SPACE AT THE COMPLETION OF THE PROJECT.
ROOM H1
EXISTING CABLE COUNT
DATA (CAT6): 0
DATA (CAT5): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
CABLE RELOCATION COUNT
DATA (CAT6): +336 FROM ROOM G03
DATA (CAT6): +34 FROM ROOM D09
DATA (CAT6): +48 FROM ROOM B97
DATA (CAT5): +48 FROM ROOM D09
DATA (CAT5): +82 FROM ROOM B97
VIDEO: +19 FROM ROOM D09
VIDEO: +1 FROM ROOM B97
PATIENT MONITORING: +8 FROM ROOM G03
PATIENT MONITORING: +58 FROM ROOM B97
COMMERCIAL WIRELESS: 0
EXISTING CABLE TO REMAIN
DATA (CAT6): 0
VIDEO: 0
PATIENT MONITORING: 0
COMMERCIAL WIRELESS: 0
FINAL CABLE COUNT
DATA (CAT6A): 548
VIDEO: 20
PATIENT MONITORING: 66
COMMERCIAL WIRELESS: 0
1/2" = 1'-0"1
ENLARGED ROOM H1 - BUILDING 05 - LIGHTING & CABLE TRAY
1/2" = 1'-0"
ENLARGED ROOM H1 - BUILDING 05 - POWER & DATA
1/4" = 1'-0"
14 - a 1/4" = 1'-0"
14 - b
1/4" = 1'-0"
14 - c
1:24
2' 3'
1:24
HAUSER
TRACY J.
10206
R E
G
IS
T
ER
ED PROFESSIONAL
EN
G
IN
E
E R
S O
U T
H D A K O
T A
R E
G . NO.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .