Drawings-589A4-22-100-2023-02-15 BID Set-Part8-pages 9.pdf

PDF 5 MB Posted

Attached to
Z2DA-- Relocate Physical Medicine and Rehabilitation to the 4th Floor PN: 589A4-22-100
Solicitation number
36C25523R0072
Issued by

About this file

This document package includes construction drawings and specifications for a federal contract opportunity to relocate a Physical Medicine and Rehabilitation department to the fourth floor of a VA medical center. The solicitation is for mechanical demolition and new work, including removal of existing piping, ductwork, equipment and installation of new systems. Drawings show demolition plans, new work plans, schedules and details. The opportunity is identified as solicitation number 36C25523R0072 to be awarded by the Department of Veterans Affairs Veterans Health Administration VISN 15. Products and services required include demolition of mechanical, plumbing and HVAC systems on the third and fourth floors, and installation of new piping, ductwork, terminal units and associated mechanical systems to support the relocated department. Construction is to take place at the VA Medical Center located at 800 Hospital Drive in Columbia, Missouri.

View the file

Other files

File Type Posted
36C25523R0072 0004.docx DOCX document
AMENDMENT 3 - Drawings.pdf PDF
AMENDMENT 3 - Specifications.pdf PDF
36C25523R0072 0003.docx DOCX document
Prebid-site visit attendee list.pdf PDF
36C25523R0072 0002.docx DOCX document
589A4-22-100 Volume 2 Specifications- 494 pages.pdf PDF
36C25523R0072 0001.docx DOCX document
Drawings-589A4-22-100-2023-02-15 BID Set- Part5-pages 10.pdf PDF
Drawings-589A4-22-100-BID Set -2-15-2023- Part1-7 pages.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set -Part4-pages 10.pdf PDF
36C25523R0072.docx DOCX document
Drawings-589A4-22-100-2023-02-15 BID Set - Part12-pages 11.pdf PDF
Drawings-589A4-22-100- 2023-02-15 BID Set-Part2- Pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part13-pages 1.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part6-pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part9-pages 8.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set - Part3-pages-12.pdf PDF
Specifications-589A4-22-100-2023-02-15 BID Set - VOL 1- Pages 785.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part11-pages 9.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part10-pages 13.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID set - Part7-pages 9.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FEC

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

7.3

8.2

9.1

6.7

10.2

9.8

8.9

8.3

7.2

7.1

8.0

7.5

2"W CAPPED

ABOVE CEILING

CAPPED ABOVE CEILING

EX 4"S-UP&DN

EX 2"W-UP

EX 4"S-UP

S

EX 4"S-DN

EX 3"W-UP

EX 2"W-UP

S

CHIRO. EXAM

ACUPUNCTURE

ACUPUNCTURE

PT/OT EXAM

PT/OT EXAM

PELVIC

PELVIC

PT/OT EXAM BARIATRIC

PT/OT STOR.

PT TLT.

PROST. STOCK RM.

PT GYM

OT TRAIN. RM.

OT TLT.

440A

ELEC.

CLEAN LINEN

450A

EQUIP.

CORR.

C44

ELEV. LOBBY / CORR.

ELEV. LOBBY

SOILED DISP

401A

PROST. CHECKIN

405A

CORR.

C45

P-422

P-302

P-529

P-117

P-116

EX 2"W-UP

P-528

P-528

P-532

P-532

P-528

P-528

EX 4"

EX 3"VS-UP&DN

EX HWR-UP&DN

EX 4"S-UP&DN

EX HW-UP&DN

EX CW-UP&DN

EX MV-UP&DN

EX MA-UP&DN

EX OX-UP&DN

EX ST-UP&DN

EX 4"

EX 4"S-UP

EX 3"V-UP&DNEX. 4"S-UP

CAPPED ABOVE CEILING

EX 1 1/2"HWR-UP&DN

EX 2 1/2"HW-UP&DN

3"CW-UP&DN

EX 4"S-DN

EX 4"S-DN

EX 4"S-UP

EX 3"W-UP

EX 4"S-UP

EX. 4"S-UP

EX. 4"S-UP

EX. 3"W-UP

EX 4"S-UP

EX 3"V-UP

4"S-DN

3"V-DN

3"V-DN

EX 3"V-UP

EX 4"V-UP

EX 4"S-UP

EX ST-UP&DN

EX 4"S-UP

EX 3"V-UP

AREA B

AREA A

AREA B

AREA A

P-528

P-414

FD-B

P-531

FD-B

P-532

P-405

FD-B

P-414

P-610

P-116

FD-B

4"S-DN

4"S-DN

4"V-DN

1/2"HW

2"W/V

1/2"CW

2"

1/2"CW

2"W/V

1/2"HW

2"V-DN

1/2"CW

2"W/V

1/2"HW

2"V/4"S-DN

1 1/4"CW

1/2" 1 1/2"

1/2"

1 1/2"

1/2"

1 1/2"

1/2"

1/2"CW

1/2"HW

2"W/V

1/2"HW

1/2"CW

1/2"HW

2"W/V

1/2"CW

1/2"HW

2"W/V

1/2"CW

2"V-DN

1/2"HW

2"W/V

1/2"CW

2"V/4"S-DN

1 1/4"CW

1/2"HW

2"W/V

1/2"CW

1/2"HW

1/2"CW

2"W/V

2"W-DN

1 1/4"CW

2"V/4"S-DN

2"V-DN

1/2"CW

2"W/V

1/2"HW

2"

1/2"

1/2"CW

2"W/V

3/4"

3/4"

1/2"

3"

4"

4"

1/2"

1/2"

1/2"

1/2"

1/2"

2"

2"

2"

2"

2"

2"

2"

2"

2"V-DN

2"

2"

1/2"HW

2"W/V

1/2"CW

4"

PT/OT SWAMP

REHAB. COOR.

STAFF TLT.

TELE HEALTH

PSA

OT SUPER.

AO

CHIEF PM&R EXAM

BREAK RM.

WAIT.

CORR.

C42

WC STOR./SHOP

CORR.

C41

CORR.

C43

CBV-2

2"V-DN

1/2"

1/2"

1 1/2"

1/2"

1/2"

1 1/2"

1 1/2"

3/4"

1 1/2"

1"

1 1/2" 1"

1 1/4"

1 1/2"

3/4"

1 1/2"

1/2"

2"

1 1/4"

3/4"

3/4"

1/2"

1 1/4"

1 1/2"

1/2"

2"

1 1/4"

1/2" 2"

1 1/4"

2 1/2"

2 1/2"

EX 2"W-UP

4"V-DN

CBV-1

CBV-3

CBV-5

1/2"

SET AT

0.5 GPM

SET AT

0.5 GPM

SET AT

0.5 GPM

SET AT

0.5 GPM

P-809 9

1/2"

4"S-DN

FOURTH FLOOR KEY PLAN

AREA B

N

B

A

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig h th in c o n e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e rs e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e s e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JOHN ERNEST SOMMERS, PE

#2015028399

PP106

PLUMBING NEW WORK PLAN - 4TH

FLOOR - AREA B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

MASJDB

3/16" = 1'-0"

PLUMBING NEW WORK PLAN - 4TH FLOOR - AREA B

1. MATCH EXISTING RISER SIZES.

2. NOT USED.

3. NOT USED.

4. NOT USED.

5. NOT USED.

6. NOT USED.

7. CONNECT NEW SINK TO EXISTING PLUMBING SANITARY

AND VENT ROUGH-IN.

8. REFER TO DETAIL #8 ON SHEET P-501 FOR

DISHWASHER DRAIN AND WATER CONNECTION.

9. INSTALL FILTRATION EQUIPMENT ABOVE ICE MAKER

UNIT. REFER TO DETAIL #9 ON SHEET P-501 FOR

FILTRATION COMPONENTS.

SHEET KEYNOTES#

# Revision Date

02/13/2023

CALIBRATED

BALANCING VALVE

SHUTOFF VALVE WITH THREADED

END CONNECTIONS (TYPICAL)

SEE PLANS

FOR PIPE SIZE

UNION

CALIBRATION

CONNECTION

POINTS

CHECK VALVE

NOTE:

0.3 GPM TO 0.7 GPM - B&G 1/2" RF MODEL OR EQUAL

0.75 GPM TO 1.0 GPM - B&G 3/4" RF MODEL OR EQUAL

1.25 GPM TO 2.5 GPM - B&G CB-1/2" MODEL OR EQUAL

SHUTOFF

VALVE (TYP.)

DIELECTRIC UNION

(TYP.)

TEMPERED

WATER TO

FIXTURES

THERMOMETER

THERMOSTATIC

MIXING VALVE

NOTE:

PROVIDE CHECK VALVE ON INLETS TO MIXING VALVES WHEN

CHECK STOPS ARE NOT PROVIDED IN MIXING VALVE ASSEMBLY.

DIRECTION

OF FLOW

CAST IRON

EXTENSION SAME

SIZE AS SEWER

UP TO 4" DIA.

FINISHED FLOOR

CLEANOUT WITH

COVER FOR DUTY

REQUIRED - SEE

SPECIFICATIONS

SEE

PLANS

BUILDING DRAIN/SEWER

(SIZE AS SPECIFIED)

CAST IRON LONG SWEEP 1/4

BEND OR CAST IRON COMB, "Y"

& 1/8 BEND. (USE REDUCING

TYPE WHERE REQUIRED)

INSULATED PIPING

PIPE SHIELD

MINIMUM 12" LONG

PIPE INSULATION

CLEVIS HANGER

THREADED HANGER ROD

THREADED HANGER ROD

PIPE INSULATION

PIPE

PIPE SHIELD

INSULATION INSERT (CALCIUM

SILICATE OR MOLDED

FIBERGLASS) BETWEEN PIPING

AND FINISHING JACKET

SECTION THRU HANGER

REFER TO SPECS FOR INSULATION

AND HANGER SUPPORTS.

TRAP

ARM

INCHES

MAXIMUM DISTANCE

TRAP TO VENT

FEET SLOPE (IN./FT.)

GENERAL NOTES:

1. FOR PIPE SIZES REFER TO

PLUMBING FIXTURE SCHEDULE

SANITARY PIPE

V E

N T

P

IP

E

FINISHED FLOOR

TABLE

1 1/4 1 1/2

4 & >

1/4 1/4 1/4 1/8 1/8

IPC

F 154-330

E 114-154

D 61-113

C 33-60

B 12-32

1-11A

SINGLE/ DOUBLE FIXTURE

FIXTURE

UNIT LOAD

PIPE

SIZE

WHA

SIZE

1/2"

3/4"

1"

1 1/4"

1 1/2"

2"

HOT OR COLD

WATER SUPPLY IF BRANCH IS GREATER THAN 20'

LONG, PROVIDE AN ADDITIONAL WHA

IN MIDDLE OF RUN. EACH SIZED

FOR HALF THE FIXTURE UNITS.

IF HORIZONTAL BRANCH IS

LESS THAN 20' LONG, PROVIDE

ONE WHA AT END OF LINE.

FIXTURE (TYPICAL)

NOTE: INSTALL PER

MANUFACTURER'S

INSTRUCTIONS. PROVIDE A WHA AT

ALL QUICK-CLOSING VALVES.

THREADED

ROD

TYPICAL 10 GAUGE

GALVANIZED PIPE

SHIELD

DOUBLE LOCKING NUT

WITH SINGLE WASHER

AT TOP AND BOTTOM

OF CHANEL STRUT

(TYPICAL)

12 GAUGE UNISTRUT

CHANNEL WITH SLOTS

UNINSULATED

PIPING

INSULATED

PIPING

PIPING INSULATION

DO NOT CRUSH

STRUT MOUNTED

IPS PIPE STRAP

NOTE:

1. HANGER ROD, NUTS, WASHER AND

PIPE STRAPS SHALL BE OF ZINC

COATED GALVANIZED PLATED

MATERIAL

2. REFER TO SPECS FOR INSULATION.

USE ISOLATION TAPE WHEN

CLAMPING UNINSULATED

NON-FERROUS PIPE

BACKSPLASH

FINISHED

FLOOR

2 COMP. SINK

ANGLE STOP

NOTE:

SIMILAR FOR OPPOSITE HAND. VERIFY FIELD CONDITIONS

PRIOR TO INSTALLATION.

DUAL OUTLET

ANGLE STOP

1/2" HW TO

DISHWASHER

DRAIN PUMP

DISHWASHER

FLEXIBLE

DRAIN

DISHWASHER

AIR GAP FITTING

COUNTERTOP

FINISHED FLOOR

P-809 IN WALL

WATER FILTER (OWNER-

FURNISHED, CONTRACTOR-

INSTALLED)

15"

(APPROXIMATE)

P-809, PIPING AND WATER FILTER

LOCATED ABOVE ICE MACHINE.

ALLOW FOR SUFFICIENT SPACE FOR

COMPONENTS WHEN LOCATING

P-809.

ICE MACHINE (OWNER

FURNISHED, CONTRACTOR

INSTALLED)

FINISHED FLOOR

MOP BASIN

5'-0" MAXIMUM5'-6" MAXIMUM

MOP SINK FAUCET

3/8" WATTS LF009 SERIES RPZ

PIPING TO CHEMICAL DISPENISING

UNIT DOWNSTREAM OF RPZ BY

OWNER.

3/8" FLEXIBLE STAINLESS HOSE

SUPPLIED (TYP OF 3)

AIR GAP FITTING

TERMINATE OVER SINK

PROVIDE 1/2" STUB OUT WITH 1/2" BALL

VALVE AND THREADED END PIECE FOR

HOSE CONNECTION

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JOHN ERNEST SOMMERS, PE

#2015028399

P-501

PLUMBING DETAILS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

MASJDB

NONE

CALIBRATED BALANCING VALVE

NONE

EMERGENCY EYEWASH THERMOSTATIC

MIXING VALVE

NONE

FLOOR CLEANOUT

NONE

INSULATED PIPE HANGER SUPPORT

NONE

TRAP TO VENT MAXIMUM DISTANCE

NONE

WATER HAMMER ARRESTOR SCHEMATIC

NONE

TRAPEZE PIPE SUPPORT

NONE

DISHWASHER DRAIN

NONE

NONE

CHEMICAL DISPENSING UNIT WATER SUPPLY AT MOP BASIN

# Revision Date

ICE MACHINE WATER SUPPLY DETAIL

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JOHN ERNEST SOMMERS, PE

#2015028399

NOT FOR

CONSTRUCTION P-601

PLUMBING SCHEDULES

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

MASJDB

PLUMBING FIXTURE SCHEDULE

PLAN

MARK

DESCRIPTION MANUFACTURER MODEL TRIM DRAIN / TRAP SUPPLIES CARRIER SEAT

HOT

WATER

COLD WATER

TEMPERED

WATER

SANITARY /

WASTE

VENT NOTES

P-116 FLOOR MOUNT WALL OUTLET WATER CLOSET - ADA ZURN Z5645-BWL

ZURN MODEL ZER6000AV-CPM-WS1, BATTERY POWERED, SENSOR OPERATED, FLUSH VALVE,

1.6 GPF

INTEGRAL - - BEMIS - 1-1/4" - 4" 2"

P-117

FLOOR MOUNT WALL OUTLET WATER CLOSET

STANDARD HEIGHT

ZURN Z5634-BWL

ZURN MODEL ZER6000AV-CPM-WS1, BATTERY POWERED, SENSOR OPERATED, FLUSH VALVE,

1.6 GPF

INTEGRAL - - BEMIS - 1-1/4" - 4" 2"

P-203 WALL HUNG URINAL ZURN Z5755-WS1-LL

ZURN MODEL ZER6003AV-CPM-WS1, BATTERY POWERED, SENSOR OPERATED, FLUSH VALVE,

1.0 GPF

INTEGRAL - WADE - - 3/4" - 2" 2"

P-204 WALL HUNG URINAL - ADA ZURN Z5755-WS1-LL

ZURN MODEL ZER6003AV-CPM-WS1, BATTERY POWERED, SENSOR OPERATED, FLUSH VALVE,

1.0 GPF

INTEGRAL - WADE - - 3/4" - 2" 2"

P-302 SINGLE-PIECE FIBERGLASS TUB / SHOWER MODULE BESTBATH STS6032A17 SYMMONS SHOWER / TUB SYSTEM MODEL S-9602-P-1.5, 1.5 GPM - - - - - - - - -

TUB / SHOWER TO NOT BE CONNECTED WITH DRAINAGE OR WATER SUPPLY. CONTRACTOR TO

PERMANTLY PLUG SHOWER DRAIN.

P-404 INTEGRAL BOWL LAVATORY BY OTHERS -

CHICAGO FAUCETS MODEL 895-317GN2AE72ABCP, 4" FIXED CENTERS, LAMINAR FLOW AT 0.5

GPM

PROVIDE WITH DRAIN PLUG - - - 1/2" 1/2" - 2" 2"

P-405 INTEGRAL LAVATORY BY OTHERS -

ARMSTRONG RADA FAUCET MODEL MX1-20, PROGRAMMABLE SENSOR OPERATED BATTERY

POWERED FAUCET

1 1/4" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS WADE - 1/2" 1/2" - 2" 2"

INSULATE SUPPLY AND WASTE PIPING WITH TRUBRO #102 WHITE INSULATION KIT WITH #105 OFFSET

DRAIN INSULATION KIT. NON-AERATED OUTLET.

P-414 WALL HUNG LAVATORY - ADA ZURN Z5340

CHICAGO FAUCETS MODEL 895-317GN2AE72ABCP, 4" FIXED CENTERS, LAMINAR FLOW AT 0.5

GPM

1 1/4" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS WADE - 1/2" 1/2" - 2" 2"

INSULATE SUPPLY AND WASTE PIPING WITH TRUBRO #102 WHITE INSULATION KIT WITH #105 OFFSET

DRAIN INSULATION KIT. 0.5 GPM NON-AERATED OUTLET.

P-422 WALL HUNG LAVATORY, BARIATRIC WILLOUGHBY BHS-3123-WB1-4CC-GW-AW PROVIDED WITH FIXTURE. 1 1/4" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS WADE - 1/2" 1/2" - 2" 2"

P-502 MOP BASIN FIAT TSBCR1000 SERIES CHICAGO FAUCETS MODEL 897-CCP, WALL MOUNTED MANUAL FAUCET W/ 8" BODY 3" CAST IRON P-TRAP INTEGRAL SUPPLY STOPS - - 1/2" 1/2" - 3" 2" #T-35 HOSE AND WALL BRACKET. 36" HOSE WITH 3/4" CHROME COUPLING. TYPE 302 STAINLESS STEEL

BRACKET WITH SPRING LOADED RUBBER GRIP.

P-528 SINGLE BOWL S/S SINK ELKAY LRAD221965

CHICAGO FAUCETS MODEL 895-317GN8AE73ABCP, MANUAL FAUCET W/ 4" WRISTBLADE, ON 4"

FIXED CENTERS W/ 8" GOOSENECK LAMINAR FLOW 1.0 GPM

1 1/2" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS - - 1/2" 1/2" - 2" 2" 1.0 GPM NON-AERATED

P-529 DOUBLE BOWL S/S SINK ELKAY LR3322PD

CHICAGO FAUCETS MODEL 786-GN8AE36ABCP, MANUAL FAUCET ON 8" CENTERS W/ 8"

GOOSENECK FAUCET, 4" WRISTBLADES, LAMINAR FLOW 1.5 GPM

1 1/2" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS - - 1/2" 1/2" - 2" 2" 1.5 GPM NON-AERATED

P-531

SINGLE BOWL FLOOR MOUNT S/S SCULLERY SINK W/

DRAINBOARD

ELKAY WNSF8124R2

CHICAGO FAUCETS MODEL 631-GN10AE35SWGAB, WALL MOUNTED MANUAL FAUCET W/ 8"

BODY, 10" GOOSENECK SWING SPOUT W/ 4" WRISTBLADE, 1.5 GPM

1 1/2" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT INTEGRAL SUPPLY STOPS - - 1/2" 1/2" - 2" 2"

P-532 SINGLE BOWL S/S SINK ELKAY LRAD221965

CHICAGO FAUCETS MODEL 895-317GN8AE73ABCP, MANUAL FAUCET W/ 4" WRISTBLADE, ON 4"

FIXED CENTERS W/ 8" GOOSENECK LAMINAR FLOW 1.0 GPM

1 1/2" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT 1/2" CHROME PLATED LOOSE KEY ANGLE STOPS - - 1/2" 1/2" - 2" 2"

1.0 GPM NON-AERATED, PROVIDE WITH WADE LAVATORY CARRIER WITH ROUND UPRIGHTS,

RECTANGULAR BASE FEET, AND A.R.C. EXPOSED ARMS TOP SUPPORT COUNTERTOP, REFER TO

ARCHITECTURAL DRAWINGS FOR LAVATORY DETAIL.

P-533 SINGLE BOWL FLOOR MOUNT S/S SCULLER SINK ELKAY IC24X24-0-X

CHICAGO FAUCETS MODEL 631-GN10AE35SWGAB, WALL MOUNTED MANUAL FAUCET W/ 8"

BODY, 10" GOOSENECK SWING SPOUT W/ 4" WRISTBLADE, 1.5 GPM

1 1/2" 17 GA CHROME PLATED BRASS P-TRAP W/ CLEANOUT INTEGRAL SUPPLY STOPS - - 1/2" 1/2" - 2" 2"

P-610

ELECTRIC WATER COOLER - BI-LEVEL W/ BOTTLE

FILLER

ELKAY LVRCGRNTL8WSK - CHROME PLATED P-TRAP CHICAGO FAUCET LOOSE KEY ANGLE STOPS AND RISERS ELKAY - - 1/2" - 2" INSTALL BOTTLE FILLER ON LOWER BI-LEVEL WATER FOUNTAIN.

P-709 SINK MOUNTED DRENCH HOSE EYEWASH W/ TMV GUARDIAN G5022BP / G6020 - - - - - - - 1/2" - - TMV TO BE MOUNTED AND INSTALLED BELOW SINK CASEWORK IN AN ACCESSIBLE LOCATION.

P-809 OUTLET BOX WITH SINGLE WATER VALVE SIOUX CHEIF 696-G1010MF - - INTEGRAL - - - 1/2" - - -

DRAIN SCHEDULE

PLAN MARK DESCRIPTION MANUFACTURER MODEL BODY STRAINER NOTES

FD-B SQUARE FLOOR DRAIN WADE 1100-G-1-2NH-4405 CAST IRON

NICKEL

BRONZE

FD-E

SQUARE FLOOR DRAIN

W/ FUNNEL

WADE

1100-G-1-2NH-4405

/ EF4-39

CAST IRON

NICKEL

BRONZE

PROVIDE WITH TRAP GUARD.

BALANCING VALVE SCHEDULE

PLAN

MARK

DESCRIPTION SIZE

ADJUSTED

FLOW RATE

NOTES

CBV-1

CALIBRATED

BALANCING VALVE

1/2" 0.5 GPM

CBV-2

CALIBRATED

BALANCING VALVE

1/2" 0.5 GPM

CBV-3

CALIBRATED

BALANCING VALVE

1/2" 0.5 GPM

CBV-4

CALIBRATED

BALANCING VALVE

1/2" 0.5 GPM

CBV-5

CALIBRATED

BALANCING VALVE

1/2" 0.5 GPM

# Revision Date

JOHN ERNEST SOMMERS, PE

#2015028399

N

X

M

T

PIPE LINE SYMBOLS

SHUT OFF VALVE (SEE

SPECIFICATION FOR TYPE)

GATE VALVE

BALL VALVE

BUTTERFLY VALVE

VALVE IN RISE (SEE SPECIFICATION FOR TYPE)

MULTI-PURPOSE PUMP DISCHARGE VALVE

CHECK VALVE

SOLENOID VALVE

PRESSURE REDUCING VALVE (HYDRONIC)

PRESSURE REGULATING VALVE (STEAM)

CALIBRATED - ORIFICE BALANCING VALVE

ACTIVE FLOW-LIMITING VALVE

PLUG VALVE

IN-LINE PUMP

Y-PATTERN STRAINER

Y-PATTERN STRAINER W/ BLOWDOWN VALVE

UNION

AIR VENT (M - MANUAL, A - AUTOMATIC)

RELIEF VALVE

VACUUM BREAKER

PRESSURE AND TEMPERATURE TEST PORT

THERMOMETER

PRESSURE GAGE WITH COCK

FLEX PIPE COUPLING

PIPE ANCHOR

PIPE GUIDE

PITCH DOWN IN DIRECTION OF ARROW

WATER METER

STEAM TRAP

TWO-WAY CONTROL VALVE

THREE-WAY CONTROL VALVE

MOTORIZED BUTTER FLY VALVE

GLOBE VALVE

A

UNIT NUMBER

EQUIPMENT DESIGNATION

TYPE OF SERVICE: S = SUPPLY

R = RETURN

E = EXHAUST

T = TRANSFER

AIR QUANTITY

IN CFM

SCHEDULED

DEVICE NO

UNIT NUMBER

DAMPER TYPE DESIGNATION

AIRFLOW MEASURING STATION

EXISTING EQUIPMENT DESIGNATION

S-1

FSD

AHU

AHU-1

ID-#

HVAC SENSOR

SENSOR TYPE

OPTIONS

SPECIALTY SENSOR TYPE

I = INSULATED BASE

G= PROVIDE GUARD

CO = CARBON MONOXIDE

CO2= CARBON DIOXIDE

NG = NATURAL GAS

T = TEMPERATURE SENSOR

H = HUMIDITY SENSOR

O = OCCUPANCY SENSOR

R = REFRIGERANT SENSOR

P = PRESSURE SENSOR

MECHANICAL SYMBOLS

ASSOCIATED UNIT

X Y

Z

ACCESS PANEL, TOP OR SIDE

TURNING VANES

MOTORIZED DAMPER

GRAVITY BACKDRAFT DAMPER

MANUAL VOLUME DAMPER

FIRE DAMPER

SMOKE DAMPER

FIRE/SMOKE DAMPER

FLOW ARROW DOWNSTREAM OF FAN

FLOW ARROW UPSTREAM OF FAN

SUPPLY DIFFUSER AS SCHEDULED. ARROWS INDICATE

DIRECTION OF AIR DISCHARGE. IF NO ARROWS ARE

SHOWN ON PLAN, DEFAULT IS A 4-WAY THROW

RETURN GRILLE OR REGISTER AS SCHEDULED

EXHAUST GRILLE OR REGISTER AS SCHEDULED

SLOT DIFFUSER AS SCHEDULED. ARROWS INDICATE DIRECTION

OF AIR DISCHARGE. IF NO ARROWS ARE SHOWN ON PLAN,

DEFAULT IS 2-WAY THROW

SIDEWALL DIFFUSER AS SCHEDULED

SIDEWALL RETURN OR EXHAUST AS SCHEDULED

DUCT SYSTEM SYMBOLS

12x12

12ø

12x10ø

FLEXIBLE DUCT

ROUND DUCT SIZE, (ACTUAL SIZE INDICATED)

CHANGE OF ELEVATION - RISE (R) OR DROP (D)

FLEXIBLE DUCT CONNECTION

SUPPLY AND OUTSIDE AIR SECTION UP

RETURN AIR SECTION UP

SPIRAL FLAT-OVAL DUCT SIZE, FIRST FIGURE

IS SIDE SHOWN (ACTUAL SIZE INDICATED)

R

DUCT SIZE, FIRST FIGURE IS SIDE

SHOWN (CLEAR INSIDE, ADJUST FOR

LINER)

SUPPLY AND OUTSIDE AIR SECTION DOWN

RETURN AIR SECTION DOWN

EXHAUST AIR SECTION UP

EXHAUST AIR SECTION DOWN

REFRIGERANT VENTRV

CHEMICAL FEEDCF

V VENT

NATURAL GASG

LPG LIQUEFIED PETROLEUM GAS

CW COLD WATER, DOMESTIC

CWS

CA

CWR

GLS

FOV

FOR

FOS

CR

CS

GLYCOL SUPPLY

FUEL OIL VENT

FUEL OIL RETURN

FUEL OIL SUPPLY

CONDENSER WATER RETURN

CONDENSER WATER SUPPLY

CHILLED WATER RETURN

CHILLED WATER SUPPLY

COMPRESSED AIR

CHR

CHS

LPS

HWS

HWR

HPR

HPS

GLR

LPR

HG

RS

RL

PC

CHILLED/HOT WATER RETURN

CHILLED/HOT WATER SUPPLY

REFRIGERANT HOT GAS

REFRIGERANT SUCTION

REFRIGERANT LIQUID

PUMPED CONDENSATE

LOW PRESSURE CONDENSATE RETURN (15 PSIG)

LOW PRESSURE STEAM SUPPLY (15 PSIG)

HEATING WATER SUPPLY

HEATING WATER RETURN

HIGH PRESSURE CONDENSATE RETURN (100 PSIG)

HIGH PRESSURE STEAM SUPPLY (100 PSIG)

GLYCOL RETURN

SRV STEAM RELIEF VENT

PUMP DISCHARGE

DRAIND

PD

FUEL OIL FILLFOF

E EQUALIZING LINE

DOMESTIC HOT WATERHW

MU MAKE-UP WATER (NON-POTABLE)

PRIMARY CHILLED WATER RETURNPCWR

PRIMARY CHILLED WATER SUPPLYPCWS

PRIMARY HEATING WATER SUPPLY

PRIMARY HEATING WATER RETURN

PHWS

PHWR

SHWS SECONDARY HEATING WATER SUPPLY

SECONDARY HEATING WATER RETURNSHWR

SECONDARY CHILLED WATER SUPPLY

SECONDARY CHILLED WATER RETURN

SCWS

SCWR

BLOW DOWNBD

CD CONDENSATE (STEAM) DRAIN

MPS

MPR

MEDIUM PRESSURE CONDENSATE

RETURN (60 PSIG)

MEDIUM PRESSURE STEAM SUPPLY (60PSIG)

PIPE SYSTEM ABBREVIATIONS

HCR

HCS

INDUCTION UNIT RETURN

INDUCTION UNIT SUPPLY

MECH EQUIPMENT DESIGNATION

MECH EQUIPMENT DESIGNATION

AC AIR CURTAIN

ACC AIR COOLED CONDENSER

ACU AIR CONDITIONING UNIT

ACV AIR CONTROL VALVE

AF AIR FILTER

AHU AIR HANDLING UNIT

AS AIR SEPARATOR

ATU AIR TERMINAL UNIT

B BOILER

BCU BLOWER COIL UNIT

BS BASKET STRAINER

BT BUFFER TANK

CAV CONSTANT AIR VOLUME

CB CHILLED BEAM

CC COOLING COIL

CFP CHEMICAL FEED PUMP

CH CHILLER

CP CONDENSER WATER PUMP

CRAC COMPUTER ROOM AIR CONDITIONING UNIT

CRP CONDENSATE RETURN PUMP

CSG CLEAN STEAM GENERATOR

CT COOLING TOWER

CTF COOLING TOWER FILTER

CU CONDENSING UNIT

CUH CABINET UNIT HEATER

CVR CONVECTOR

CWP CHILLED WATER PUMP

DFH DEAERATING FEEDWATER HEATER

DHU DESSICANT DEHUMIDIFICATION UNIT

DMC DUCT MOUNTED COIL

EAV EXHAUST AIR VALVE

EF EXHAUST FAN

EJ EXPANSION JOINT

ERU ENERGY RECOVERY UNIT

ET EXPANSION TANK

EVC EVAPORATIVE COOLER

F FAN

FAV FUME AIR VALVE

FC FLUID COOLER

FCU FAN COIL UNIT

FD FIRE DAMPER

FFU FAN FILTER UNIT

FSD COMBINATION FIRE/SMOKE DAMPER

FT FLASH TANK

FTR FIN-TUBE RADIATION

FTU FAN TERMINAL UNIT

FUR GAS FIRED FURNACE (*NEED APPROVAL)

GMU GLYCOL MAKEUP UNIT (*NEED APPROVAL)

GP GLYCOL PUMP

GV GRAVITY VENTILATOR

H HUMIDIFIER

HC HEATING COIL

HEV HOOD EXHAUST VALVE

HPU HEAT PUMP UNIT

HRU HEAT RECOVERY UNIT

HWP HEATING WATER PUMP

HX HEAT EXCHANGER

L LOUVER

MAU MAKE-UP AIR UNIT

MD MOTORIZED DAMPER

P PUMP

PAC PACKAGED AIR CONDITIONING UNIT

PCWP PRIMARY CHILLED WATER PUMP

PG PIPE GUIDE

PHWP PRIMARY HEATING WATER PUMP

PHX PLATE HEAT EXCHANGER

PRV PRESSURE REGULATING VALVE

PTAC PACKAGED TERMINAL AIR CONDITIONER

RF RETURN FAN

RHC TERMINAL REHEAT COIL

RP RADIANT PANEL

RTU ROOFTOP UNIT

RV ROOF VENTILATOR (*NEED APPROVAL)

SA SOUND ATTENUATOR

SAV SUPPLY AIR VALVE

SCWP SECONDARY CHILLED WATER PUMP

SD SMOKE DAMPER

SF SUPPLY FAN

SHWP SECONDARY HEATING WATER PUMP

SPP STEAM PRESSURE PUMP

SSCU SPLIT SYSTEM CONDENSING UNIT (*NEED APPROVAL)

SSFU SPLIT SYSTEM FAN/COIL UNIT (*NEED APPROVAL)

ST STEAM TRAP

T TANK

TCP TEMPERATURE CONTROL PANEL

UH UNIT HEATER

VAV VARIABLE AIR VOLUME BOX

VFD VARIABLE FREQUENCY DRIVE

VI VIBRATION ISOLATION

VRF VRF INDOOR UNIT

VRHU VRF HEAT RECOVERY UNIT (*NEED APPROVAL)

WCC WATER COOLED CONDENSER

WSHP WATER SOURCE HEAT PUMP

MECHANICAL ABBREVIATIONS

A AIR OR AMP (PER CONTEXT)

ACC ACCESSORIES

AD ACCESS DOOR

AFF ABOVE FINISHED FLOOR

AFS AIR FLOW SWITCH

AHRI AIR CONDITIONING, HEATING, AND

REFRIGERATION INSTITUTE

AI ANALOG SIGNAL INPUT

AMB AMBIENT

AO ANALOG SIGNAL OUTPUT

AP ACCESS PANEL

APD AIR PRESSURE DROP

APLV APPLICATION PART LOAD VALUE

APPROX APPROXIMATE

ARCH ARCHITECTURE/ARCHITECT

AUX AUXILIARY

AV AUTOMATIC VENT

AVG AVERAGE

BDD BACK DRAFT DAMPER

BFC BELOW FINISHED CEILING

BFP BACKFLOW PREVENTER

BHP BRAKE HORSEPOWER

BI BINARY SIGNAL INPUT

BMS BUILDING MANAGEMENT SYSTEM

BO BINARY SIGNAL OUTPUT

BOB BOTTOM OF BEAM

BOD BOTTOM OF DUCT

BOP BOTTOM OF PIPE

BS BEAM SPACE

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNITS PER HOUR

BWE BAKED WHITE ENAMEL

CAP CAPACITY

CAV CONSTANT AIR VOLUME

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

CI CAST IRON

CLG COOLING DUCT (COLD DUCT)

CO CLEAN OUT

COMP COMPRESSOR

CONC CONCRETE

COND CONDENSATE

CONN CONNECTION

CORR CORRIDOR

CV CONTROL VALVE

D DEPTH

DB DRY BULB

DBA A-WEIGHTED DECIBELS

DEFL DEFLECTION

DEG DEGREES

DEG F DEGREES FAHRENHEIT

DES DESIGN

DIA DIAMETER

DIM DIMENSION

DISCH DISCHARGE

DIV DIVISION

DN DOWN

DP DIFFERENTIAL PRESSURE SENSOR

DPS DIFFERENTIAL PRESSURE SWITCH

DPT DIFFERENTIAL PRESSURE TRANSMITTER

DTL DETAIL

DWG(S) DRAWING(S)

EA EXHAUST AIR OR EACH (PER CONTEXT)

EAT ENTERING AIR TEMPERATURE

EER ENERGY EFFICIENT RATIO

EFF EFFICIENCY

ELEC ELECTRIC

ELEV ELEVATION

EQ EQUAL

ESP EXTERNAL STATIC PRESSURE

EWB ENTERING AIR WET BULB TEMPERATURE

EWT ENTERING WATER TEMPERATURE

EXH EXHAUST

EXIST, EX EXISTING

EXT EXTERNAL

F FAHRENHEIT

F&T FLOAT AND THERMOSTATIC

FC FLEXIBLE CONNECTION

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FIN FINISHED

FLR FLOOR

FPF FINS PER FOOT

FPM FEET PER MINUTE

FS FLOW SWITCH

FT FEET

FT-HD HEAD IN FEET

GA GAUGE

GAL GALLONS

GALV GALVANIZED

GC GENERAL CONTRACTOR

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

H HEIGHT

HD HEAD

HEV HOSE END VALVE

HORIZ HORIZONTAL

HP HORSEPOWER

HR HOUR

HTG HEATING DUCT (HOT DECK)

HVAC HEATING, VENTILATING & AIR

CONDITIONING

HW HOT WATER

HZ HERTZ

IB INVERTED BUCKET

IE INVERT ELEVATION

IN INCH/INCHES

INDIC INDICATOR

IPLV INTEGRATED PART-LOAD VALUE

ISP INTERNAL STATIC PRESSURE

JS JOIST SPACE

KW KILOWATTS

L LENGTH

LAT LEAVING AIR TEMPERATURE

LB(S) POUNDS

LF LINEAR FEET

LRA LOCKED ROTOR AMPS

LS LIGHT SPACE

LVL LEVEL

LWT LEAVING WATER TEMPERATURE

MAN MANUAL

MANU MANUFACTURER

MAX MAXIMUM

MBH THOUSAND BRITISH THERMAL UNITS PER

HOUR

MCA MINIMUM CIRCUIT AMPS

MCC MOTOR CONTROL CENTER

MECH MECHANICAL

MERV MINIMUM EFFICIENCY REPORTING VALUE

(ASHRAE 52.2)

MFR MANUFACTURER

MIN MINIMUM OR MINUTE (PER CONTEXT)

MTD MOUNTED

MTL METAL

MV MANUAL VENT

NC NORMALLY CLOSED OR NOISE CRITERIA

(PER CONTEXT)

NIC NOT IN CONTRACT

NO NORMALLY OPEN OR NUMBER (PER CONTEXT)

NOM NOMINAL

NPLV NON-STANDARD PART LOAD VALUE

NPSH NET POSITIVE SUCTION HEAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OBD OPPOSED BLADE DAMPER

OC ON CENTER

OD OUTSIDE DIAMETER

OT OIL TRAP

PA PIPE ANCHOR

PBD PARALLEL BLADE DAMPER

PD PRESSURE DROP

PENT PENTHOUSE

PH PHASE

PHC PREHEAT COIL

PLBG PLUMBING

PNEU PNEUMATIC

PPH POUNDS PER HOUR

PRESS PRESSURE

PRV PRESSURE REGULATING VALVE

PSI POUNDS PER SQUARE INCH

PSIA POUNDS PER SQUARE INCH ABSOLUTE

PSIG POUNDS PER SQUARE INCH GAUGE

QTY QUANTITY

RA RETURN AIR

RAD RADIATED

RD ROOF DRAIN

REFR REFRIGERANT

REQ REQUIRED

RH RELATIVE HUMIDITY

RLA RUNNING LOAD AMPS

RM ROOM

RND ROUND

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SAN SANITARY

SEC'N SECTION

SEER SEASONAL ENERGY EFFICIENCY RATIO

SENS SENSIBLE

SF SQUARE FOOT

SH SENSIBLE HEAT

SHT SHEET

SND SOUND

SOL SOLENOID

SP STATIC PRESSURE

SPD STATIC PRESSURE DIFFERENTIAL

SPT STATIC PRESSURE TRANSMITTER

SQ SQUARE

SST STAINLESS STEEL

STL STEEL

STM STEAM

T&P TEMPERATURE AND PRESSURE

TC TEMPERATURE CONTROL

TD THERMODYNAMIC OR TEMPERATURE

DIFFERENTIAL (PER CONTEXT)

TDH TOTAL DYNAMIC HEAD

TEMP TEMPERATURE

TOT TOTAL

TPD TOTAL PRESSURE DROP

TSP TOTAL STATIC PRESSURE

TYP TYPICAL

UC UNDERCUT DOOR

UG UNDERGROUND

UNO UNLESS NOTED OTHERWISE

V VOLTS

VAC VACUUM

VD VOLUME DAMPER (MANUAL)

VEL VELOCITY

VERT VERTICAL

VFD VARIABLE FREQUENCY DRIVE

VOL VOLUME

VTR VENT THRU ROOF

W WATT OR WIDTH (PER CONTEXT)

W/ WITH

W/O WITHOUT

WB WET BULB

WC WATER COLUMN

WG WATER GAUGE

WPD WATER PRESSURE DIFFERENTIAL

WT WEIGHT

MECHANICAL PROJECT GENERAL NOTES

1. ALL ELBOWS, FITTINGS, ETC., IN PIPING AND DUCTWORK REQUIRED

TO CLEAR ALL JOB OBSTRUCTIONS ARE NOT NECESSARILY

INDICATED. ALL NECESSARY TRANSITIONS, FITTINGS AND OFFSETS

ARE REQUIRED WHETHER SHOWN OR NOT.

2. BECAUSE OF THE LIMITED SPACE AVAILABLE TO INSTALL ALL OF THE

MECHANICAL WORK, COORDINATION BETWEEN THE VARIOUS

TRADES IS OF THE UTMOST IMPORTANCE. SEE SPECIFICATION

230100 FOR REQUIRED COORDINATION DRAWINGS.

3. THE CONTRACTOR SHALL COORDINATE STAGING AND SCHEDULING

WITH THE OWNER'S REPRESENTATIVE.

4. EXISTING CONDITIONS ARE BASED ON INFORMATION OBTAINED

FROM PREVIOUS CONSTRUCTION DOCUMENTS AND INFORMAL

FIELD OBSERVATION AND SHALL NOT BE CONSTITUTED AS "AS

BUILT." THE CONTRACTOR SHALL FIELD-VERIFY EXISTING

CONDITIONS BEFORE THE ONSET OF CONSTRUCTION.

5. DEMOLISH ALL PIPING, DUCTWORK EQUIPMENT, ETC., SHOWN TO BE

REMOVED, IN ITS ENTIRETY, INCLUDING ALL HANGERS AND

SUPPORTS.

6. WHERE CONTRACTOR IS REQUIRED TO CONCEAL NEW WORK,

REMOVE OR MODIFY EXISTING CONSTRUCTION OR EQUIPMENT, OR

ATTACH TO EXISTING CONSTRUCTION, THE CONTRACTOR SHALL

REPAIR OR REPLACE EXISTING CONSTRUCTION AND MATERIALS TO

MATCH CONDITIONS AT THE ONSET OF CONSTRUCTION. IT IS THE

CONTRACTOR'S RESPONSIBILITY TO REMOVE AND REPLACE

EXISTING CEILINGS AND WALLS REQUIRED FOR INSTALLATION OF

MECHANICAL SYSTEMS.

7. THE OWNER SHALL MAINTAIN ALL SALVAGE RIGHTS OF EQUIPMENT

AND MATERIALS REMOVED. ALL EQUIPMENT AND MATERIALS NOT

CLAIMED BY THE OWNER SHALL BE REMOVED FROM THE PREMISES

BY THIS CONTRACTOR.

8. CONTRACTOR SHALL PROVIDE SEISMIC BRACING AND MOUNTING OF

EQUIPMENT AND MATERIALS IN COMPLIANCE WITH ALL LOCAL CODE

REQUIREMENTS AND THE REQUIREMENTS OF SPECIFICATION

SECTION SEISMIC PROTECTION.

9. ALL WORK SHALL BE INSTALLED PER THE REFERENCE DETAILS,

REGARDLESS OF WHETHER OR NOT THE DETAILS ARE CALLED OUT

ON THE PLANS.

10. PROVIDE VENTS AT ALL HYDRONIC PIPING HIGH POINTS, AND

DRAINS AT ALL PIPING LOW POINTS, REGARDLESS OF WHETHER

SHOWN OR NOT.

11. THE CONTRACTOR SHALL VERIFY ALL REFRIGERANT PIPE SIZING

AND ROUTINGS WITH THE EQUIPMENT MANUFACTURER. THE

CONTRACTOR SHALL ALSO PROVIDE ALL REQUIRED REFRIGERANT

ACCESSORIES AS RECOMMENDED BY THE EQUIPMENT

MANUFACTURER FOR COMPLETE AND FULLY FUNCTIONAL SYSTEMS.

12. DO NOT SCALE THE LOCATION OF HVAC CEILING ELEMENTS, SUCH

AS AIR INLETS AND OUTLETS, FROM THE M-SERIES DRAWINGS. SEE

ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT HVAC

CEILING ELEMENT LOCATIONS. REFLECTED CEILING PLANS GOVERN

THE LOCATION OF DIFFUSERS, REGISTERS, AND GRILLES. M-SERIES

DRAWINGS GOVERN TYPE, STYLE, AND SIZE OF DIFFUSERS,

REGISTERS, AND GRILLES.

13. ALL DUCTWORK SHALL COMPLY WITH "HVAC DUCT CONSTRUCTION

STANDARDS - METAL AND FLEXIBLE," 3RD EDITION, SMACNA 2005,

EXCEPT WHERE MORE RESTRICTIVE REQUIREMENTS ARE

SPECIFIED. ANY PLAN REFERENCES TO "SMACNA FIGURE ---"

REFERS TO THIS STANDARD. SEE SPECIFICATIONS FOR SCHEDULE

OF DUCT PRESSURE CLASS AND SEAL CLASS.

14. IN GENERAL, THE FINAL FLEX DUCT RUNOUT TO EACH DIFFUSER,

REGISTER, OR GRILLE IS NOT SIZED ON PLANS. FLEX DUCT RUNOUT

SIZE SHALL MATCH AIR OUTLET NECK SIZE, UNO.

15. IT IS THE INTENT OF THESE DRAWINGS THAT A MANUAL BALANCING

DAMPER BE PROVIDED AT EVERY INDIVIDUAL DUCTED CONNECTION

TO AN AIR DEVICE, UNLESS A BALANCING DAMPER IS SCHEDULED

TO BE FURNISHED WITH AIR DEVICE. VAV BOXES WITH SINGLE

DIFFUSERS ARE NOT REQUIRED TO HAVE A BALANCING DAMPER.

16. ALL NEW DUCTWORK SIZES SHOWN ON PLANS ARE CLEAR INSIDE

DIMENSIONS. CONTRACTOR SHALL ADJUST SHEET METAL SIZES AS

NECESSARY TO ACCOMMODATE INTERNAL DUCT LINER, IF

SPECIFIED.

17. ALL EXISTING TEMPERATURE CONTROLS THAT ARE BEING

DEMOLISHED OR DISABLED AS WORK OF THIS CONTRACT SHALL BE

COMPLETELY REMOVED FROM BUILDING.

18. THE CONTRACTOR SHALL CONNECT THE NEW HVAC SYSTEM TO THE

OWNER'S EXISTING BUILDING CONTROL SYSTEM. REFER TO THE

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

19. CONTRACTOR SHALL HAVE THE DOCUMENTS REVIEWED

COMPLETELY BY A CERTIFIED BALANCING CONTRACTOR FOR THE

INCLUSION OF THE NECESSARY ADDITIONAL AIR AND HYDRONIC

SYSTEM BALANCING DEVICES NOT SHOWN IN THESE DOCUMENTS

FOR COMPLETE HVAC SYSTEM BALANCING. REFER TO

SPECIFICATION SECTION 230593 FOR CONSTRUCTION DOCUMENT

EXAMINATION REPORT.

20. IT SHOULD BE NOTED THAT SOME SYSTEMS (I.E. GENERAL AND

ISOLATION EXHAUST) ARE REQUIRED TO BE BALANCED MORE THAN

ONCE TO ASSURE DESIGN AIRFLOWS ARE PROVIDED.

21. THESE PLANS ARE DIAGRAMMATIC IN NATURE. THE CONTRACTOR

SHALL BE PREPARED TO MAKE SOME ALTERATIONS TO THE EXACT

LOCATION OF DUCTWORK, PIPING AND EQUIPMENT FROM THE

LOCATION INDICATED ON THESE DRAWINGS TO FIT ACTUAL JOB

CONDITIONS.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

M-000

MECHANICAL SYMBOLS AND

ABBREVIATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

# Revision Date

John Ernest Sommers, PE

PE-2015028399

TEMP.

WAIT.

TEMP. MSA

FOURTH FLOOR KEY PLAN

AREA A

N

B

A

PHASING LEGEND

AFFECTED AREA

NOTES:

1. PAIN CLINIC - NORTHWEST QUADRANT OF THE FLOOR - SHALL BE OPERATIONAL AT ALL

WORKING DAYS & HOURS (MON-FRI 7M - 5PM) DURING THE ENTIRE CONSTRUCTION

PERIOD. ANY REQUIRED WORK IN THIS CLINIC SHALL BE COORDINATED CLOSELY W/

COR.

TEMPORARY PARTITION

EXISTING PARTITIONS

DEMO PARTITION

EXISTING AREA

AFTER-HOURS AFFECTED AREA

5PM-6AM PLUS WEEKENDS & HOLIDAYS ONLY

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

M-001

MECHANICAL PHASING PLANS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

# Revision Date

1/16" = 1'-0"

MECHANICAL PHASING PLAN - 4TH FLOOR - PHASE 1

1/16" = 1'-0"

MECHANICAL PHASING PLAN - 4TH FLOOR - PHASE 2

1/16" = 1'-0"

MECHANICAL PHASING PLAN - 4TH FLOOR - PHASE 3

1/16" = 1'-0"

MECHANICAL PHASING PLAN - 4TH FLOOR - PHASE 4

John Ernest Sommers, PE

F E

C

ABCDEEaFGGaHJJbK BaBbH.5Ja F.1 Eb Aa

2.8

3.7

6.2

5.4

5.7

5.3

4.6

3.6

4.1

4.7

5.1

6.1

6.3

1.9

5.5

1.1

3.1

4.4

NOT IN SCOPE

3" UP

3"

EX 3" HCR

EX 2" V

EX 1" MPS

1. REFER TO M000 FOR MECHANICAL SYMBOLS AND

ABBREVIATIONS.

2. COORDINATE PHASING AND SHUTDOWN FOR SUPPLY

AIR, RETURN AIR, HEATING HOT WATER SUPPLY, AND

HEATING HOT WATER RETURN WITH OWNER.

SHUTDOWN AND REPLACEMENT TO OCCUR AFTER

HOURS OR OVER WEEKEND.

3. COORDINATE EXISTING CONDITIONS AND ASBESTOS

REMOVAL WITH EXISTING CONDITIONS. FOR EXISTING

ASBESTOS, REFER TO MOST RECENT REPORT

PROVIDED BY OWNER. COORDINATE ALL REMOVAL IN

COMPLIANCE WITH CURRENT VA ASBESTOS

ABATEMENT DESIGN MANUAL. REFER TO

SPECIFICATION 02 82 11 FOR ADDITIONAL

INFORMATION.

4. PAIN CLINIC - NORTHWEST QUADRANT OF THE FLOOR -

SHALL BE OPERATIONAL AT ALL WORKING DAYS &

HOURS (MON-FRI 7M - 5PM) DURING THE ENTIRE

CONSTRUCTION PERIOD. ANY REQUIRED WORK IN THIS

CLINIC SHALL BE COORDINATED CLOSELY W/ COR.

GENERAL NOTES#

1. VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION.

2. DEMOLISH EXISTING PIPING FROM FLOOR ABOVE TO

DEMARCATION POINT SHOWN.

SHEET KEYNOTES#

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

MD101

MECHANICAL DEMOLITION PLAN -

PIPING - 3RD FLOOR - AREA A

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

1/8" = 1'-0"

MECHANICAL DEMOLITION PLAN - PIPING - 3RD FLOOR - AREA A

# Revision Date

John Ernest Sommers, PE

FE

F E

T

T

T

T

ABCDEEaFGGaHHbJJbKLLaMNNa BaBbH.5Ja F.1 Eb AaMaNb

2.8

3.7

7.3

8.2

9.1

10.4

4.5

6.2

5.4

6.7

5.7

5.3

4.6

10.2

9.8

8.9

8.3

7.2

7.1

3.6

4.1

4.7

5.1

6.1

6.3

8.0

1.9

5.5

7.5

1.1

3.1

4.4

ROOF TOP EQUIPMENT

EXISTING TO REMAIN

HE

HE

HE

HE

HE

HE

E

MD103

1 1

MD106

MD104

1 1

MD107

NOT IN SCOPE

1. REFER TO M000 FOR MECHANICAL SYMBOLS AND

ABBREVIATIONS.

2. COORDINATE PHASING AND SHUTDOWN FOR SUPPLY

AIR, RETURN AIR, HEATING HOT WATER SUPPLY, AND

HEATING HOT WATER RETURN WITH OWNER.

SHUTDOWN AND REPLACEMENT TO OCCUR AFTER

HOURS OR OVER WEEKEND.

3. COORDINATE EXISTING CONDITIONS AND ASBESTOS

REMOVAL WITH EXISTING CONDITIONS. FOR EXISTING

ASBESTOS, REFER TO MOST RECENT REPORT

PROVIDED BY OWNER. COORDINATE ALL REMOVAL IN

COMPLIANCE WITH CURRENT VA ASBESTOS

ABATEMENT DESIGN MANUAL. REFER TO

SPECIFICATION 02 82 11 FOR ADDITIONAL

INFORMATION.

4. PAIN CLINIC - NORTHWEST QUADRANT OF THE FLOOR -

SHALL BE OPERATIONAL AT ALL WORKING DAYS &

HOURS (MON-FRI 7M - 5PM) DURING THE ENTIRE

CONSTRUCTION PERIOD. ANY REQUIRED WORK IN THIS

CLINIC SHALL BE COORDINATED CLOSELY W/ COR.

GENERAL NOTES#

FOURTH FLOOR KEY PLAN

N

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

MD102

MECHANICAL DEMOLITION PLAN - 4TH

FLOOR - OVERALL

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

3/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - 4TH FLOOR - OVERALL

# Revision Date

John Ernest Sommers, PE

1. REFER TO M000 FOR MECHANICAL SYMBOLS AND

ABBREVIATIONS.

2. COORDINATE PHASING AND SHUTDOWN FOR SUPPLY

AIR, RETURN AIR, HEATING HOT WATER SUPPLY, AND

HEATING HOT WATER RETURN WITH OWNER.

SHUTDOWN AND REPLACEMENT TO OCCUR AFTER

HOURS OR OVER WEEKEND.

3. COORDINATE EXISTING CONDITIONS AND ASBESTOS

REMOVAL WITH EXISTING CONDITIONS. FOR EXISTING

ASBESTOS, REFER TO MOST RECENT REPORT

PROVIDED BY OWNER. COORDINATE ALL REMOVAL IN

COMPLIANCE WITH CURRENT VA ASBESTOS

ABATEMENT DESIGN MANUAL. REFER TO

SPECIFICATION 02 82 11 FOR ADDITIONAL

INFORMATION.

4. PAIN CLINIC - NORTHWEST QUADRANT OF THE FLOOR -

SHALL BE OPERATIONAL AT ALL WORKING DAYS &

HOURS (MON-FRI 7M - 5PM) DURING THE ENTIRE

CONSTRUCTION PERIOD. ANY REQUIRED WORK IN THIS

CLINIC SHALL BE COORDINATED CLOSELY W/ COR.

GENERAL NOTES#EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

2.8

3.7

4.5

6.2

5.4

6.7

5.7

5.3

4.6

7.1

3.6

4.1

4.7

5.1

6.1

6.3

5.5

3.1

4.4

3/4"

3/4"

2"

1 1/4"

1"

1" 3/4"

3/4" typical size VAV connection

1 1/4"

2"

1"

1"

1 1/2"

1 1/4"

1 1/4"

1 1/2"

3"

6" HCS UP &

DN

1"1"

3/4"

3/4"

HCR DN

2" AT.MOS.VENT

TO 6TH FL.

1" MPS(30#)

UP & DN

UP

UP

5"

3" 3"

5" HCR UP

HCR

HCR HCR

T

T

T

T

T

T

TT

T

T

T

T

T

T T

T

T

NOT IN SCOPE

3 3

1 1/4"

1 1/2"

22 2 2 2 2

EX 1/2" D

EX 1" HCS 5

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1/2" D

EX 1" HCS

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

1. DEMOLISH ALL EXISTING TERMINAL UNITS AND

ASSOCIATED PIPING, CONTROLS, AND ACCESSORIES

BACK TO DEMARCATION POINT SHOWN.

2. EXISTING INDUCTION UNIT TO BE REMOVED. REMOVE

CONTROLS AND ACCESSORIES. REMOVE PIPING BACK

ABOVE CEILING AND PREPARE FOR CONNECTION TO

NEW INDUCTION UNIT PIPING LOOP. REMOVE ALL

CONTROL WIRING BACK TO CENTRAL PANEL IN 401C.

REMOVE ALL PNEUMATIC CONTROL TUBING.

3. DEMOLISH EXISTING PIPING FROM FLOOR BELOW TO

DEMARCATION POINT SHOWN.

4. DEMOLISH EXISTING PIPING BACK TO DEMARCATION

POINT SHOWN.

5. DEMOLISH INDUCTION UNIT SUPPLY AND CONDENSATE

PIPING BACK TO 4TH FLOOR SLAB AND CEILING.

PREPARE FOR CONNECTION OF NEW PIPING. INSTALL

NEW INDUCTION UNIT SUPPLY AND CONDENSATE

PIPING PRIOR TO DEMOLITION OF EXISTING PIPING. SEE

NEW WORK FOR RELATED INFORMATION.

SHEET KEYNOTES#

FOURTH FLOOR KEY PLAN

AREA A

N

B

A

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

MD103

MECHANICAL DEMOLITION PLAN -

PIPING - 4TH FLOOR - AREA A

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

3/16" = 1'-0"

MECHANICAL DEMOLITION PLAN - PIPING - 4TH FLOOR - AREA A

# Revision Date

John Ernest Sommers, PE

FE

F E

T

TT

T

TT

1. REFER TO M000 FOR MECHANICAL SYMBOLS AND

ABBREVIATIONS.

2. COORDINATE PHASING AND SHUTDOWN FOR SUPPLY

AIR, RETURN AIR, HEATING HOT WATER SUPPLY, AND

HEATING HOT WATER RETURN WITH OWNER.

SHUTDOWN AND REPLACEMENT TO OCCUR AFTER

HOURS OR OVER WEEKEND.

3. COORDINATE EXISTING CONDITIONS AND ASBESTOS

REMOVAL WITH EXISTING CONDITIONS. FOR EXISTING

ASBESTOS, REFER TO MOST RECENT REPORT

PROVIDED BY OWNER. COORDINATE ALL REMOVAL IN

COMPLIANCE WITH CURRENT VA ASBESTOS

ABATEMENT DESIGN MANUAL. REFER TO

SPECIFICATION 02 82 11 FOR ADDITIONAL

INFORMATION.

4. PAIN CLINIC - NORTHWEST QUADRANT OF THE FLOOR -

SHALL BE OPERATIONAL AT ALL WORKING DAYS &

HOURS (MON-FRI 7M - 5PM) DURING THE ENTIRE

CONSTRUCTION PERIOD. ANY REQUIRED WORK IN THIS

CLINIC SHALL BE COORDINATED CLOSELY W/ COR.

GENERAL NOTES#EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

7.3

8.2

9.1

6.7

9.8

8.9

8.3

7.2

7.1

8.0

7.5

2"

2"

3/4"

2"

2" 1 1/4"

1"

1" 3/4"

3/4"

2"

1" typical size VAV connection

2"

3/4"

2"

1"

2"

1"

1 1/4"

2"

1"

1"

1 1/2" 1 1/4"

3/4"

3/4"

EX 6" MPS UP &

DN

EX 8" CWR UP

& DN

EX 3" HWS UP

& DN

EX 3" HWR UP

& DN

EX 8" CWS UP

& DN

EX 1 1/4" EXP

UP & DN

4"

3/4"

3/4"

- 5' 0" LG x 1'-6" VERT.

EXP.LOOP AT CLG

1' - 0" RAD. BEND -

UP & DN

UP

UP

EX 4" MPC UP

& DN

T

22222222222222

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1" HCS

EX 1/2" D

EX 1/2" D

EX 1" HCS 4

FOURTH FLOOR KEY PLAN

AREA B

N

B

A

1. DEMOLISH ALL EXISTING TERMINAL UNITS AND

ASSOCIATED PIPING, CONTROLS, AND ACCESSORIES

BACK TO DEMARCATION POINT SHOWN.

2. EXISTING INDUCTION UNIT TO BE REMOVED. REMOVE

CONTROLS AND ACCESSORIES. REMOVE PIPING BACK

ABOVE CEILING AND PREPARE FOR CONNECTION TO

NEW INDUCTION UNIT PIPING LOOP. REMOVE ALL

CONTROL WIRING BACK TO CENTRAL PANEL IN 401C.

REMOVE ALL PNEUMATIC CONTROL TUBING.

3. VERIFY SHUTOFF VALVES EXIST AND ADD NEW AS

REQUIRED FOR NEW WORK.

4. DEMOLISH INDUCTION UNIT SUPPLY AND CONDENSATE

PIPING BACK TO 4TH FLOOR SLAB AND CEILING.

PREPARE FOR CONNECTION OF NEW PIPING. INSTALL

NEW INDUCTION UNIT SUPPLY AND CONDENSATE

PIPING PRIOR TO DEMOLITION OF EXISTING PIPING. SEE

NEW WORK FOR RELATED INFORMATION.

SHEET KEYNOTES#

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

NOT FOR

CONSTRUCTION

JOHN SOMMERS, PE MO #2015028399

MD104

MECHANICAL DEMOLITION PLAN -

PIPING - 4TH FLOOR - AREA B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

RLCJES

3/16" = 1'-0"

MECHANICAL DEMOLITION PLAN - PIPING - 4TH FLOOR - AREA B

# Revision Date

John Ernest Sommers, PE

File details come from the government source that posted it. Updated .