Drawings-589A4-22-100-2023-02-15 BID Set -Part4-pages 10.pdf

PDF 5 MB Posted

Attached to
Z2DA-- Relocate Physical Medicine and Rehabilitation to the 4th Floor PN: 589A4-22-100
Solicitation number
36C25523R0072
Issued by

About this file

This package includes architectural drawings and specifications for renovating physical medicine and rehabilitation spaces to the fourth floor at a VA medical center. Key details include relocating these departments from various first floor locations to a centralized fourth floor area. The drawings show new layouts for exam rooms, therapy gyms, training rooms, storage, support spaces, and restrooms. Product requirements include millwork, fixtures, equipment, wall coverings and signage. Construction documents are at the bid stage, with the solicitation number 36C25523R0072 and project number 589A4-22-100. The VA and their architect oversee the project to upgrade these facilities.

View the file

Other files

File Type Posted
36C25523R0072 0004.docx DOCX document
AMENDMENT 3 - Drawings.pdf PDF
AMENDMENT 3 - Specifications.pdf PDF
36C25523R0072 0003.docx DOCX document
Prebid-site visit attendee list.pdf PDF
36C25523R0072 0002.docx DOCX document
589A4-22-100 Volume 2 Specifications- 494 pages.pdf PDF
36C25523R0072 0001.docx DOCX document
Drawings-589A4-22-100-2023-02-15 BID Set- Part5-pages 10.pdf PDF
Drawings-589A4-22-100-BID Set -2-15-2023- Part1-7 pages.pdf PDF
36C25523R0072.docx DOCX document
Drawings-589A4-22-100-2023-02-15 BID Set - Part12-pages 11.pdf PDF
Drawings-589A4-22-100- 2023-02-15 BID Set-Part2- Pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part13-pages 1.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part6-pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part9-pages 8.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set - Part3-pages-12.pdf PDF
Specifications-589A4-22-100-2023-02-15 BID Set - VOL 1- Pages 785.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part8-pages 9.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part11-pages 9.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part10-pages 13.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID set - Part7-pages 9.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R E

F

F E

C

F E

C

F E

C

FOURTH FLOOR KEY PLAN

AREA B

N

B

A

BREAK RM.

CHIEF PM&R

EXAM

OT SUPER.

PSA

TELE

HEALTH

STAFF TLT.

REHAB.

COOR.

CORR.

C43

CORR.

C43

PT/OT

SWAMP

PT GYM

WAIT.

WC

STOR./SHOP

PT GYM

CLEAN LINEN

450A

PT/OT EXAM

BARIATRIC

PT/OT STOR.

PT TLT.

PT/OT EXAM

PT/OT EXAM

OT TLT.

440A

OT TRAIN.

RM.

PELVIC

PELVIC

ACUPUNCTURE

ACUPUNCTURE

CHIRO. EXAM

PROST.

STOCK RM.

ELEV. LOBBY

SOILED DISP

401A

PROST.

CHECKIN

405A

ELEV. LOBBY

/ CORR.

CORR.

C41

CORR.

C44

ELEC.

0E

30088E

30117E

30116E

30113E

30114E

30059E

30061E

30060E

30062E

30063E

30065E

30066E

30046E

6E

30044E

2E

3E

30034E

30073E

30041E

3E

3E

30043E

30045E30074E

30026E

45024E 45022E 45022E 45026E 45026E

45027E

1E

30049E

30056E

1E

7E

0E

0E

8E

30025E

30053E

45028E

45023E

45035E

45030N 45030E

0E

1E

1E

2E

1E

1E

30035E

30069E

1E

30003E

3E

30048E

30002E

AI402 D2

D1

AI401

AI401

A3

B3

F2000 30114E

M0506

F2000

F2000

F2000

F2010

A5075

A5090

A1015

F2000

A1015

A1015

30029E 30029E 30029E 30030E30030E

30033E

R4650

30039E

30078E

M4100

A5107 30072E

A5200

F2000

A1015 A1015A1015

A1015

A1015

30058E 30058E

A1015 A1015

30058E

30058E

30058E

30058E

F2000

A1015

A1015

A1015

A1015 A1015

M1801

30064E

A1015

30064E M1801

30115E

30089E

30130E

30132E

30146E

30124E

30140E

A5145

30112E

A1015

30064E

A1015

30057E 30058E

30064E

A1015

30057E

30057E

A1015

30057E

30057E

30057E

A5077

F2000

30084E

30084E

30084E

30084E

30084E

30084E

30084E

4E

4E F2020

F

A5075

A5082

A5200

F2010

A5205

A5195

A5075

A5080

F2000A5106

30010E

30007E

30005E

A5145

30016E

30017E

F2020

E0945

2E

30058E

A5145

A5210

A5220

1E

A1067

A1014 A1066

A5210

9E

A5109

A5109

A101530057E

A1015

30050E

M3073

M3070

A5077

A5107

F2020

A5075

A5080

8E

5E

5E

9N

9E

9E

9E

4E

9E

9E

9N

9E

AO

A1015

F2000

A1015

A5145

A5145

A5145

A5145

30007E

A5180

30107E 30107E

6E

30108E

1E

A1014

30084E

30038E 30040E

30037E

30036E

30042E 30080E

30018E

30019E

30027E 30077E

M1825

A1014

AI204

D4

AI204

D2

AI204

B4

AI204

B1

M1801

A1015

30087E

F0860 30146E

A5106

A5077

A1015

30064E

A1080

A1015

A1015

F0860

F3010

F3050

A5145

F3200

F3200

F3200

F3200

F3200

F3200

A5075A5080

F3200

F3200

A5145A5145

A5145A5145

4E 30

4E

4E

A5109

50001N

F3200

30096E

A5212

M0515

A5220

A5212

M0515

A5220

A5170

F3200

F0860

F0860

AI403 B2

50003N

F3200

A5220

K2515

AI403B1

AI401 C3

A5109

A1067

A5082

F3200

M4116

F2000

50002N

F3200 A5108

A5180

A5077

A5107

A5145A5145

A1012

M3073

A5080

A5075

B3

F

F

3N

50020N

30110E

A5180

A5180 A5180

A5180

A5109A5109A5109

A5109

50022N

WORK

AREA

F3200

45032E

45034E

45037E

M1801

A1015

F2000

F3200

F2000

A1012

45036E

M1801

A1015

45032E

45033E

50023N50023N

M0515

A5212

A5220

A5109A5109A5109A5109

R7250

R7250

K4665

K1552

A5075

A1012

A5145

A5109

A5090

AE401

A3

SIM

AE401

B3

SIM

AE401

C6

SIM

A5145A5145

A5145

30015E

F0860

50019N

50019N

50019N

50019N

50019N

50019N

50020N

50020N50020N

50020N50020N

50020N

50019N50020N

50019N50020N

STG.

404A 30084E50020N50020N

50019N

C4

CRASH CART

ALCOVE

EQUIP.

CLO.

439A

50019N

E0954

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig h th in c o n e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e rs e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e s e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI203

EQUIPMENT PLAN - 4TH FLOOR - AREA

B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

N

3/16" = 1'-0" D2

EQUIPMENT PLAN - 4TH FLOOR - AREA B

0' 2'-8" 5'-4" 10'-8"

NOTE: PROVIDE METAL BACKING FOR ALL ITEMS ATTACHED TO WALLS, INCLUDING ITEMS TO BE FURNISHED AND INSTALLED BY OTHERS.

# Revision Date

M9025

FITTING/EXAM

RM.

AI401

C5

C6

FITTING/EXAM

RM.

A5075 A5107

F3200

M3073

A1012

A5145A5145

A5077

M9025

AI401

C5SIM

C6

SIM

A5075 A5107

M3073

A1012

A5145A5145

A5077

A5180

A5180A5080

F3200

A5080

CHIRO. EXAM

CHIRO. EXAM

A5077

A5077

A5075

A5080

M3073

F0355

M9025 F0355

A1012

A5075

M3073

A5108

AI402

B1

A5080

A5107

A5107

A5180

M9025A5108

A5

A1012

AI402 A5

SIM

B1SIM

M3070

M3070

M1801

F3200

A5145A5145

A5145A5145

A5180

F3200

ACUPUNCTURE

ACUPUNCTURE

50007N

F0355

30139E

A5077

30138E

30145E

F0355

M3073

A5080

M3073

A5077

30141E

A5107

A5107

50007N

30091E

M3070

A5180

A5180

A5145A5145

A5145A5145

AI402

B3

B2

AI402 B2

SIM

B3SIM

F3200

A1012

A1012

F3200

A5108 A5075

A5108 A5075

A5080

30102E

30105E

M3073

A1012

M3073

6E

30104E

A5075

A5080

A5077

30100E

A5080

A5075

E0948

A1012

A5077

30101E

M3070

PELVIC

PELVIC

A5107 A5145A5145

A5145A5145

A5107

M0506

M0506

9E

AI402

B4

B5

AI402B5

SIM

B4SIM

M1800

M1803

A5210

A5210

A5108

F3200

50002N

A5108

F3200

A5180

A5180

50002N

M4116

M3073

A5080

A5075

A1012

A5108 A5107

PT/OT EXAM

BARIATRIC

A5077

A5180

A5145

A5145

AI403

A2

A1

F3200

F2000

AI402

C2

30094E

M4116

30127E

M3073

30133E

30093E

PT/OT EXAM

PT/OT EXAM

A5108

A5080

A5075A5077

A5107

C1

AI402 C1

SIM

C2SIM

F3200

A5145A5145 A1012

A5180

A5080

A5075A5077

A5107 A5145A5145 A1012

A5180

30129E

A5108

F3200

M3073

FITTING/EXAM

RM.

A5080

45018E

A5075

A5107

M3073

A5180

A1012

A5077

F3200

AI401 D5

D4

A5145A5145

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI204

ENLARGED PLANS - EQUIPMENT

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

1/2" = 1'-0" D5

ENLARGED PLAN - FITTING/EXAM ROOM

1/2" = 1'-0"

D1

ENLARGED PLAN - CHIRO EXAM ROOM

1/2" = 1'-0" D2

ENLARGED PLAN - ACUPUNCTURE ROOM

1/2" = 1'-0"

D4

ENLARGED PLAN - PELVIC EXAM ROOMS

1/2" = 1'-0" B1

ENLARGED PLAN - PT/OT BARIATRIC ROOM

1/2" = 1'-0"

B4

ENLARGED PLAN - PT/OT EXAM ROOM

1/2" = 1'-0" B2

ENLARGED PLAN - FITTING/ EXAM ROOM

F

C

F E

C

FEC

WALL PROTECTION LEGEND

CORNER GUARD

END WALL GUARD

ANGLE WALL GUARD

HANDRAIL WITH CRASH RAIL (HR-1, CR-X)

RIGID WALL COVERING WITH CHAIR RAIL (RWC-X.3, CH-1)

KEY:

CG -X.X

REFERS TO COLOR, REF CSK

REFERS TO HEIGHT, REF CSK

GENERAL NOTES

1. INSTALL ALL WALL CORNER GUARDS, END GUARDS, & ANGLE GUARDS

ABOVE FLOOR BASE.

2. INSTALL ALL RIGID VINYL SHEET ABOVE FLOOR BASE.

3. REFER TO COLOR SCHEDULE KEY AND SPECIFICATIONS MANUAL FOR

WALL PROTECTION MANUFACTURER, SIZE & COLOR.

4. "F" STANDS FOR FULL HEIGHT.

RIGID WALL COVERING WITH CRASH RAIL

AND WALL GUARD (RWC-2.3, CR-2, WG-1)

RIGID WALL COVERING (RWC-X.X)

HYGENIC WALL CLADDING (HWC 1.X)

CRASH RAIL (CR-X)

FIRST FLOOR KEY PLAN

AREA A

N

B A

C

PROST.

CHIEF

PROST.

ASST. CHIEF

PROST. REP

STAFF TLT.

FUME RM.

PLASTER

MAINT.

421A

DUST RM.

STOR.

426A

CLEAN LAB

PER. CLNC.

MASSAGE

PER. CLNC.

GROUP RM.

HSKPG.

PROST.

PURCHASING

FITTING/EXAM

RM.

FITTING/EXAM

RM.

PROST.

WAIT.

CHIRO. EXAM

CHIRO. EXAM

BREAK RM.

WOMEN'S

TLT

MEN'S TLT

MSA

CHECKIN/OUT

ANTE

FITTING/EXAM

RM.

ELEV. LOBBY

/ CORR.

CG-1.F

CG-2.F

CG-2.F

CG-2.F

CG-1.F

CG-1.F

CG-1.F

CG-1.F

CG-1.F

CG-1.F

CG-1.F CG-1.F

CG-1.F

CG-1.F

CG-1.FCG-1.F

CG-1.F

CG-2.F

CG-2.F

CG-1.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F CG-2.F CG-2.F

CG-2.F

CG-2.F CG-2.F CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.FCG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F

CG-2.FCG-2.F

CG-2.F

CG-2.F

HR-1, CR-1

RWC-1.3

RWC-3.3, CH-1

H R

-1 C

R -1

H R

-1 C

R -1

HR-1, CR-1

HR-1, CR-1

H R

-1 C

R -1

H R

-1 C

R -1

H R

-1 C

R -2

HR-1, CR-2HR-1, CR-2

HR-1, CR-2

H R

-1 C

R -2

HR-1, CR-1 HR-1, CR-2HR-1, CR-2

RWC-2.3

RWC-1.3

RWC-1.3

HR-1, CR-1

HR-1, CR-1

HR-1, CR-1

CR-1

HR-1, CR-1HR-1, CR-1

HR-1, CR-1

HWC-1.3

RWC-2.3

RWC-2.3RWC-2.3

RWC-2.3

H R

-1 C

R -1

H R

-1 C

R -1

H R

-1 C

R -1

H W

C -1

.3

HWC-1.3

H W

C -1

.3

HWC-1.3

HR-1, CR-1

H R

-1 C

R -1

HR-1, CR-1

CG-1.F CG-1.F

CG-3.F

CG-3.F

CG-3.F

CG-1.F

CG-1.F CG-1.F

HWC-1.F

HWC-1.F

HWC-1.F

HWC-1.F

CG-2.F

HR-1, CR-1HR-1, CR-1

HR-1, CR-1

HR-1, CR-1HR-1, CR-1

H R

-1 C

R -2

PROST.

STOCK RM.

PROST.

CHECKIN

405A

ELEV. LOBBY

WC

STOR./SHOP

WAIT.

R W

C -3

.3 C

H -1

CR-1

STOP

HR-1

AT FEC

CR-1

STOP

HR-1

AT FEC

R W

C -2

.3

HR-1, CR-1 CR-1

STOP

HR-1 AT

EWC

C R

-1

OI&T RM.

RWC-1.3

RWC-1.3

RWC-1.3

CG-1.F

CG-1.F

CG-2.F

CG-2.F

CG-2.FCG-2.F

CG-1.F

CG-2.F

CG-2.F

CG-2.F

ALL WALLS

THIS ROOM

CG-1.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

RWC-2.3

CG-2.F

RWC-2.F

RWC-2.FRWC-2.F

CG-3.F

RWC-5.F

RWC-5.F

RWC-5.7

RWC-5.7 RWC-5.7 RWC-5.7

RWC-5.F

RWC-5.F

RWC-5.F

" 7

RWC-6.2RWC-6.2 RWC-6.2 RWC-5.F

RWC-2.3

ALL WALLS

THIS ROOM

RIGID WALL COVERING

(RWC) AS SCHEDULED

INSTALL RESILIENT BASE TO

WP W/ SPECIAL ADHESIVE AS

RECOMMENDED BY

MANUFACTUER

INSTALL BOTTOM OF WP

1/16" FROM FINISHED

FLOOR

GYP. BD.

GYP. BD.

METAL COVE CAP

COVE STICK AS REQ'D

BY MANUFACTURER

SHEET FLOORING

MATERIAL, REF.

FINISH SCHED. & CSK

CLEAR SILICONE CAULK AT

COVE CAP & BOTTOM OF RWC

RIGID WALL COVERING

(RWC) AS SCHEDULED

/1

N T

S

TOP CAP, REF SPEC & CSK

RIGID WALL COVERING (RWC) OR

HYGIENIC WALL CLADDING (HWC) AS

SCHEDULED

CLEAR SILICONE CAULK AT

TOP CAP & WALL JOINT

A .F

.F

R E

F C

S K

GYP. BD.

HIGH-IMPACT

RESILIENT COVER

FASTENER

CONTINUOUS

ALUMINUM

RETAINER

BLOCK'G

AS REQ'D

CLEAR SILICONE CAULK

AT TOP OF CHAIR RAIL

& WALL JOINT

RIGID WALL COVERING

(RWC) AS SCHEDULED

A .F

.F

R E

F C

S K

GYP. BD.

A .F

.F

R E

F C

S K

HIGH-IMPACT

RESILIENT COVER

FASTENER

CONTINUOUS

ALUMINUM

RETAINER

BLOCK'G

AS REQ'D

CONTINUOUS

IMPACT BUMPER 7

/4

CLEAR SILICONE CAULK AT

TOP OF WALL GUARD &

WALL JOINT

RIGID WALL COVERING

(RWC) AS SCHEDULED

GYP. BD.

RIGID WALL COVERING

(RWC) WHERE OCCURS

GYP. BD.

HIGH-IMPACT

RESILIENT COVER

FASTENER

CONTINUOUS

ALUMINUM

RETAINER

BLOCK'G

AS REQ'D

CONTINUOUS

IMPACT BUMPER

CLEAR SILICONE CAULK

AT TOP OF CRASH RAIL

& WALL JOINT

BASE AS

SCHEDULED

A .F

.F

R E

F C

S K

GYP. BD.

FASTENER

CONTINUOUS

ALUMINUM RAIL

BLOCK'G

AS REQ'D

STAINLESS

STEEL MOUNTING

BRACKET

1 1/2" 1 1/2"

3"

CLEAR SILICONE CAULK

AT TOP OF BRACKET &

WALL JOINT

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI301

WALL PROTECTION PLAN - 4TH FLOOR

- AREA A

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

3/16" = 1'-0" D2

WALL PROTECTION PLAN - 4TH FLOOR - AREA A

N

0' 2'-8" 5'-4" 10'-8"

6" = 1'-0" B1

DETAIL - WALL PROT AT RESILIENT BASE

6" = 1'-0"

B2

DETAIL - WALL PROT AT COVE BASE

6" = 1'-0" A1

DETAIL - WALL PROTECTION TOP CAP

3" = 1'-0"

A5

DETAIL - CHAIR RAIL

3" = 1'-0" A4

DETAIL - WALL GUARD

3" = 1'-0"

A3

DETAIL - CRASH RAIL

3" = 1'-0" A2

DETAIL - HANDRAIL

F

C

F E

C

F E

C

FOURTH FLOOR KEY PLAN

AREA B

N

B

A

CHIRO. EXAM

ACUPUNCTURE

ACUPUNCTURE

PT/OT EXAM

PT/OT EXAM

PELVIC

PELVIC

PT/OT EXAM

BARIATRIC

PT/OT STOR.

PT TLT.

PROST.

STOCK RM.

PT GYM

AO

OT SUPER.

BREAK RM.

STAFF TLT.

REHAB.

COOR.

PSA

PT/OT

SWAMP

CHIEF PM&R

EXAM

WAIT.

OT TRAIN.

RM.

OT TLT.

440A

CRASH CART

ALCOVE

ELEC.

WC

STOR./SHOP

CLEAN LINEN

450A

EQUIP.

CORR.

C43

CORR.

C44

ELEV. LOBBY

SOILED DISP

401A

TELE

HEALTH

RWC-2.3, CR-2, WG-1

R W

C -4

.3 C

H -1

RWC-4.3, CH-1

RWC-4.3, CH-1

RWC-2.3

R W

C -2

.3

RWC-2.3

RWC-2.3

H R

-1 C

R -1

HR-1, CR-1 HR-1, CR-1

R W

C -2

.3

HR-1, CR-1 HR-1, CR-2

H R

-1 C

R -2

H R

-1 C

R -2

R W

C -2

.3

R W

C -1

.3

RWC-2.3RWC-2.3RWC-2.3

CG-2.FCG-2.F CG-2.FCG-2.F CG-2.FCG-2.F CG-2.F CG-2.F CG-2.F CG-2.FCG-2.FCG-2.FCG-2.FCG-2.F

CG-1.F

CG-1.F

CG-1.F CG-1.F

CG-1.F CG-1.F

CG-1.FCG-1.F

CG-1.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

HWC-1.3

RWC-2.3

H R

-1 C

R -1

R W

C -2

.3

RWC-2.3

RWC-2.3

R W

C -2

.3

RWC-2.3

RWC-2.3RWC-2.3

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F

CG-2.F

CG-2.F CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F CG-2.F

CG-2.FCG-2.FCG-2.FCG-2.FCG-2.FCG-2.FCG-2.FCG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F CG-2.F

CG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

ALL WALLS

THIS ROOM

CG-2.F

CG-2.F

R W

C -1

.3

RWC-1.3RWC-1.3

R W

C -1

.3

RWC-2.3

R W

C -2

.3

RWC-2.3

RWC-2.3

RWC-2.3

R W

C -2

.3

RWC-2.3

ALL WALLS

THIS ROOM

H R

-1 C

R -2

H R

-1 C

R -2

H R

-1 C

R -2

H R

-1 C

R -2

H R

-1 C

R -2

H R

-1 C

R -2

RWC-2.3, CR-2, WG-1 CG-2.FCG-2.F

CG-2.F

CG-2.F CG-2.F CG-2.F CG-2.F

CG-2.F

CG-2.F

CG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-1.F CG-1.F

CG-2.F CG-2.F

CG-2.F

CG-2.F

HWC-1.3

HWC-1.3HWC-1.3

HWC-1.3HWC-1.3HWC-1.3HWC-1.3

CG-1.F CG-1.F

PROST.

CHECKIN

405A

R W

C -2

.3

STG.

404A

CLO.

439A

CG-2.F

CR-2

STOP

HR-1

AT FEC

CUT OUT

RWC-2.3

AROUND

FEC

RWC-2.3 CG-2.F

HR-1, CR-1

CG-2.F

CG-2.FCG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

PROVIDE

BACKING FOR

FUTURE

HANDRAIL

PROVIDE

BACKING FOR

FUTURE

HANDRAIL

PROVIDE

BACKING FOR

FUTURE

HANDRAIL

PROVIDE

BACKING FOR

FUTURE

HANDRAIL

CG-1.F

RWC-1.3

RWC-1.3

RWC-1.3

RWC-1.3

RWC-1.3

RWC-1.3

CG-1.F

CG-1.F

CG-2.F

CG-2.F

RWC-2.3

RWC-2.3

RWC-2.3

CG-2.F

CR-1

C R

-1

HR-1, CR-1

STOP

HR-1 AT

EWC

HR-1, CR-1

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-2.F

CG-1.F

CG-2.F

CG-2.F

CG-2.F

RWC-2.3, CR-2, WG-1RWC-2.3, CR-2, WG-1

RWC-2.3

WALL PROTECTION LEGEND

CORNER GUARD

END WALL GUARD

ANGLE WALL GUARD

HANDRAIL WITH CRASH RAIL (HR-1, CR-X)

RIGID WALL COVERING WITH CHAIR RAIL (RWC-X.3, CH-1)

KEY:

CG -X.X

REFERS TO COLOR, REF CSK

REFERS TO HEIGHT, REF CSK

GENERAL NOTES

1. INSTALL ALL WALL CORNER GUARDS, END GUARDS, & ANGLE GUARDS

ABOVE FLOOR BASE.

2. INSTALL ALL RIGID VINYL SHEET ABOVE FLOOR BASE.

3. REFER TO COLOR SCHEDULE KEY AND SPECIFICATIONS MANUAL FOR

WALL PROTECTION MANUFACTURER, SIZE & COLOR.

4. "F" STANDS FOR FULL HEIGHT.

RIGID WALL COVERING WITH CRASH RAIL

AND WALL GUARD (RWC-2.3, CR-2, WG-1)

RIGID WALL COVERING (RWC-X.X)

HYGENIC WALL CLADDING (HWC 1.X)

CRASH RAIL (CR-X)

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI302

WALL PROTECTION PLAN - 4TH FLOOR

- AREA B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

N

3/16" = 1'-0" D2

WALL PROTECTION PLAN - 4TH FLOOR - AREA B

0' 2'-8" 5'-4" 10'-8"

A. CONTRACTOR & SUBCONTRACTORS TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS

AT THE PROJECT SITE.

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

45032E

A1012

45019E

50003N

F2000

9.09

45032E

26.01

A5109A5109

A5200

A5090

A5082

A1067

25"

6.40D

9.09A

9.09B

10.01A

12.22

22.01

26.31

A5109

A5075

11.50A

22.10A

6.40B

6.40E

30" FILLER

1"

/2

6.40H

B5

AI501

A5090

A5090

9.09A

9.09B

22.10A

22.10A

11.50A

A5109A5109A5109

A5145

A5145

A4995

A5109A5109A5109

10.01A

A5200

A5200

F2010

A5075

A5082

B2

AI501

A1067A1067

71"

" 6.40D

9.09B

9.09A

12.22

22.01

11.50A

26.31

6.40B

12"

/2

26.31

A1067

25"

6.40D 9.09A

9.09B

12.22

22.01

22.10A

A5200

A5090

A5109A5109A5109

10.01A

26.31

M1801

M1801

A1015

A1015

F2000

45036E

9.08

A1067

25"

6.40D

9.09A

9.09B

12.22

22.01

22.10A

26.31

11.50A

11.50A

A5200

A5109A5109

10.01A

A5109

F2010

9.09B

9.09A

22.1122.11

22.10A

11.50A

10.02

26.01 A4995

A5145

A5200

A5109A5109A5109

10.02

10.01A

A1067A1067

A5082

F2010

A5075

B2

AI501

71"

6.40D

9.09B

9.09A 12.22

22.01

11.50A

26.31

6.40B

/2

12"

26.31 A1067

A5082

F2010

25"

6.40D

9.09B

9.09A

10.02

12.22

22.01

22.11

11.50A

26.31

6.40B

6.40E

FILLER

1"

30"

/2

6.40H

B5

AI501

RWC-2.3

50020N

50019N

F2020

9.09

CG-2.F

A5080

A5075

A5107

M3073

A1012

A5145A5145

A5077

A5180

A1

AI501

B1

AI501

D1

AI501

24"24"1" FILLER

18"30"

6.40B

6.40D

9.09

12.21

22.01

12.23

6.40A

6.40E

6.40E

26.01

6.40B

M9025

F3200

CG-2.F

A5080

A5107

A5075

M3073

15"

24"

6.40B

9.09

12.21

22.01

12.23

6.40A

6.40E

6.40E

A1067 A5145

A5082

A5075

9.09B

9.09A

22.01

26.31

A5109A5109

A1067

A5082

A5075

A5200

A5090 9.09B

9.09A

22.01

22.10A

26.31

26.01

A5109

F2010

A5109A5109

A5200

A5090

9.09B

9.09A

22.10A

A5109

50015N 50012N

B4

AI501

SIM

9.09

12.2412.24

48"

45018E

A5080

A5107

A5075

M3073

15"

6.40B

22.01

12.21

6.40A

12.23

9.09

11.50A

6.40E

24" 30" 18"

1" FILLER 24" 24"

D3

AI501

A5080

A5075

A5107

M3073

A1012

A5180

A5145A5145

A5077

6.40B

12.21

22.01

6.40A 9.09

12.23

6.40E

26.01

26.01

6.40B

22.04

50019N

50020N

30084E 30084E

CG-2.F

9.09

RWC-2.3RWC-2.3

RWC-5.7

RWC-6.2

RWC-5.7 RWC-5.7 RWC-5.FRWC-5.7RWC-5.F

9.09

CG-3.F

1.01A 1.01B

1.01C1.01C

CG-3.F

EQ.

3/8"

EQ. EQ.

3/8"

EQ.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI401

INTERIOR ELEVATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

KEYNOTES

KEY VALUE KEYNOTE TEXT

1.01A REMOVE AND REINSTALL EXISTING SIGNAGE.

1.01B REMOVE AND REINSTALL EXISTING TV.

1.01C BRING ELEVATOR CALL BUTTONS AND INDICATORS OUT TO FACE

OF NEW PANEL SYSTEM.

6.40A PLASTIC LAMINATE BASE CABINET

6.40B PLASTIC LAMINATE WALL CABINET WITH SLOPED TOP U.O.N.

6.40D PLASTIC LAMINATE SINK ENCLOSURE

6.40E PLASTIC LAMINATE FINISHED END

6.40H CABINET LOCK - REF. SPEC.

9.08 GWB SOFFIT.

9.09 WALL BASE AS SCHEDULED.

9.09A BASE TILE PT-1.

9.09B WALL TILE PT-2.

10.01A FLOOR MOUNTED TOILET PARTITION, REF. SPECS.

10.02 URINAL SCREEN - WALL HUNG, REF. SPEC.

11.50A CEILING MOUNTED PATIENT LIFT SYSTEM - 770 LBS CAPACITY.

PARALLEL RAILS RECESSED INTO CEILING. VA SUPPLIED AND

INSTALLED UNDER A SEPARATE CONTRACT. THIS CONTRACTOR TO

COORDINATE LIFT LOCATION W/ MEP ELEMENTS.

12.21 SOLID SURFACE COUNTERTOP.

12.22 SOLID SURFACE COUNTERTOP WITH INTEGRAL LAVATORY.

12.23 1-INCH RADIUS CORNER

12.24 COUNTERTOP SUPPORT BRACKET.

22.01 SINK - REF. PLUMBING.

22.04 PLASTER TRAP - REF. PLUMBING

22.10A ADA TOILET - REF. PLUMBING.

22.11 URINAL - REF. PLUMBING.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

26.31 LIGHT FIXTURE - SEE ELEC.

1/4" = 1'-0" A3

ELEV - 402 PROST. STOCK RM. - N

1/4" = 1'-0"

A4

ELEV - 402 WOMENS TOILET - E

1/4" = 1'-0" A5

ELEV - 402 WOMENS TOILET - N

1/4" = 1'-0" B1

ELEV - 402 WOMENS TOILET - S

1/4" = 1'-0"

B2

ELEV - 402 WOMENS TOILET - W

1/4" = 1'-0" B3

ELEV - 402A PROST. CHECK IN - N

1/4" = 1'-0"

B4

ELEV - 403 MENS TOILET - E

1/4" = 1'-0" B5

ELEV - 403 MENS TOILET - N

1/4" = 1'-0" C1

ELEV - 403 MENS TOILET - S

1/4" = 1'-0"

C2

ELEV - 403 MENS TOILET - W

1/4" = 1'-0" C3

ELEV - 404 WC STOR/SHOP - E

1/4" = 1'-0"

C5

ELEV - 412 FITTING/EXAM ROOM - N

1/4" = 1'-0" C6

ELEV - 412 FITTING/EXAM ROOM - W

1/4" = 1'-0" D1

ELEV - 414 STAFF TIOLET - E

1/4" = 1'-0"

D2

ELEV - 414 STAFF TOILET - N

1/4" = 1'-0" D3

ELEV - 414 STAFF TOILET - W

1/4" = 1'-0"

D6

ELEV - 422 FUME - S

1/4" = 1'-0" D4

ELEV - 419 FITTING/EXAM RM - N

1/4" = 1'-0"

D5

ELEV - 419 FITTING/EXAM RM - E

1/4" = 1'-0" C4

ELEV - 404 WC STOR/SHOP - W

1/4" = 1'-0" A1

ELEV - 400 ELEVATOR LOBBY - N

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

A5075

A5106

A5080

42 1/8"

6.40D

9.09

12.21

22.01

22.05

F3050 F3010

45015E

M1801

A1011

A1011

45012E45012E

50019N

45003E A1011

9.09

26.01

26.01

M9025

A5080

A5075

M3073

F0355

CG-2.FCG-2.F

15"

24"

6.60A

6.40B

6.40D

6.40A

9.09

12.21

22.01

12.23

6.40E

6.40E

11.50A

M3070

A1012

A5107

A5145A5145

A5080

A5075

A5077

A1

AI501

B1

AI501

D1

AI501

CG-2.F

1" FILLER 30" 30"

1" FILLER

30" 30"

6.40B

6.40D

6.40A 9.09

12.21

22.01

12.23

6.40E

6.40E

26.01

6.40B 3

A5080

30141E

M3073

30145E

A5108

15"

24"

CG-2.F

6.60A

6.40B

6.40A

9.09

12.21

22.01

12.23

6.40E

6.40E

11.50A

A5075

A5108

A5077

A5145A5145

A1012

D1

AI501

B1

AI501

A1

AI501

CG-2.F

1" FILLER 24" 24"

18"30"

6.40B

6.40D

6.40A

9.09

12.21

22.01

12.23

6.40E

6.40E 26.01 3

A5077

A5107

A5145

A5145

A1012

A5080

A5075

A5180

15"

24"

6.40B

6.40A

9.09

12.21

22.01

12.23

6.40E

6.40E

26.01

26.01

30099E

A5080

A5075

M0506

M1803

M1800

30105E

30102E

A1

AI501

D1

AI501

B1

AI501

CG-2.F

1" FILLER

24" 24"

30" 18"

6.40B

6.40D

6.40A

9.09

12.21

22.01

12.23

11.50A

6.40E

6.40E

26.0126.01

6.40B

A5080

A5075

M3073

30127E

30133E

6.60A

CG-2.F

15"

24"

6.40B

6.40D

6.40A9.09

12.21

22.01

12.23

6.40E

6.40E

11.50A

A5080

A5075 A1012

A5145A5145

A5107

A5077

A1

AI501

B1

AI501

D1

AI501

1" FILLER

30" 30"

1" FILLER

30" 30"

6.40B

6.40A

6.40D

9.09

12.21

22.01

12.23

6.40E

6.40E 26.01

6.40B

A1067

A5082

A5145

9.09B

9.09A

A5075 F2010

22.14

26.01

A5109

A5200

A5090

A5109

9.09B

9.09A

22.10A

A5109

26.01

A5090

A5200

A5109A5109

A5082

A5075

A1067

22.10A

9.09B

9.09A

26.31

22.14

A5109

1 1/2" FILLER

12" 42 1/2"

1" FILLER

15"

30017E

/2

B1

AI501

A4

AI501

A3

AI501

1 1/2" FILLER

12" 30"

FILLER

24"

6.40B6.40B

6.40A

12.21

22.36

9.08

11.0811.08

6.40F

6.40E

6.40E

6.40A

9.08

6.40B

30015E

30016E K2515

F2020

B3

AI501

B4

AI501

SIM

B1

AI501

A3

AI501

K3401

15"

1" FILLER

12" 12" 12" 36" 12" 12" 12" 30"

1 1/8" FILLER

25" 15" 12" 36" 24" 12"

30017E

6.40B6.40B

6.40C

6.40A

12.2122.01

6.40H

6.40H

9.08

11.0811.08

11.0811.08

6.40E

6.40E

"A5109

A5195

A5205

1' - 3"

1' - 4" 2

9.09B

9.09A

22.10B

22.13B

A5170

A5109A5109

A5109A5109A5109

A5109

30005E

30006E

30007E30007E

30003E 2

22.13B

3' - 6"

A5109

22.13C

A5109

22.13B

A5109A5109

A5195

A5145

A5080

A5075

A1066

F2000

22.10B

D2

AI501

42"

1' - 4" 2

" 6.40D

9.09B

9.09A

12.23

6.40E

26.31

A5109

12.22

22.01

A5170

30006E

9.09B

9.09A

A5145

22.13B

A5109A5109

22.13B

A5075

F0775

F2020

A5077

A5080

A1

AI501

2 1/8" FILLER30"33"33"30"2 1/8" FILLER

6.40B

9.09 22.01

6.40B

HWC-1.F

22.04

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI402

INTERIOR ELEVATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

KEYNOTES

KEY VALUE KEYNOTE TEXT

6.40A PLASTIC LAMINATE BASE CABINET

6.40B PLASTIC LAMINATE WALL CABINET WITH SLOPED TOP U.O.N.

6.40C PLASTIC LAMINATE SINK CABINET

6.40D PLASTIC LAMINATE SINK ENCLOSURE

6.40E PLASTIC LAMINATE FINISHED END

6.40F PLASTIC LAMINATE BLANK PANEL

6.40H CABINET LOCK - REF. SPEC.

6.60A SOLID SURFACE WDW SILL, REF. FINISH SCHEDULE

9.08 GWB SOFFIT.

9.09 WALL BASE AS SCHEDULED.

9.09A BASE TILE PT-1.

9.09B WALL TILE PT-2.

11.08 COORDINATE REQUIRED CLEARANCE AT CASEWORK FOR

EQUIPMENT.

11.50A CEILING MOUNTED PATIENT LIFT SYSTEM - 770 LBS CAPACITY.

PARALLEL RAILS RECESSED INTO CEILING. VA SUPPLIED AND

INSTALLED UNDER A SEPARATE CONTRACT. THIS CONTRACTOR TO

COORDINATE LIFT LOCATION W/ MEP ELEMENTS.

12.21 SOLID SURFACE COUNTERTOP.

12.22 SOLID SURFACE COUNTERTOP WITH INTEGRAL LAVATORY.

12.23 1-INCH RADIUS CORNER

22.01 SINK - REF. PLUMBING.

22.04 PLASTER TRAP - REF. PLUMBING

22.05 EYE WASH - REF. PLUMBING.

22.10A ADA TOILET - REF. PLUMBING.

22.10B LOW HEIGHT FLOOR MOUNTED TOILET, REF. PLUMBING.

22.13B RESIDENTIAL STYLE TUB/SHOWR UNIT, REF. PLUMBING.

22.13C SHOWER HEAD - REF. PLUMBING.

22.14 ADA-COMPLIANT BARIATRIC LAVATORY, REF. PLUMBING.

22.36 HOOD - REF. MECHANICAL.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

26.31 LIGHT FIXTURE - SEE ELEC.

1/4" = 1'-0" A2

ELEV - 424 LAB CLEAN ROOM - N

1/4" = 1'-0"

A3

ELEV - 424 LAB CLEAN ROOM - S

1/4" = 1'-0" A5

ELEV - 430 CHIRO. EXAM ROOM - E

1/4" = 1'-0" B1

ELEV - 430 CHIRO. EXAM ROOM - S

1/4" = 1'-0"

B2

ELEV - 432 ACUPUNCTURE - E

1/4" = 1'-0" B3

ELEV - 432 ACUPUNCTURE - S

1/4" = 1'-0"

B4

ELEV - 434 - PELVIC ROOM - S

1/4" = 1'-0" B5

ELEV - 434 - PELVIC ROOM - W

1/4" = 1'-0" C1

ELEV - 436 - PT/OT EXAM ROOM - E

1/4" = 1'-0"

C2

ELEV - 436 - PT/OT EXAM ROOM - S

1/4" = 1'-0" C3

ELEV - 437 PT TOILET - N

1/4" = 1'-0"

C4

ELEV - 437 PT TOILET - S

1/4" = 1'-0" C5

ELEV - 437 PT TOILET - W

1/4" = 1'-0" D1

ELEV - 440 OT TRAIN. RM. CABINETRY - N

1/4" = 1'-0"

D2

ELEV - 440 OT TRAIN. RM. CABINETRY- E

1/4" = 1'-0" D3

ELEV - 440A OT TOILET - E

1/4" = 1'-0"

D4

ELEV - 440A OT TOILET - N

1/4" = 1'-0" D5

ELEV - 440A OT TOILET - S

1/4" = 1'-0"

D6

ELEV - 440A OT TOILET - W

1/4" = 1'-0" A1

ELEV - 423 PLASTER - N

B. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

C. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE THE

DRAWINGS.

D. ALL MATERIALS & EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.

E. DETAILS SHOWN ARE TYPICAL UNLESS OTHERWISE NOTED. SIMILAR DETAILS APPLY IN

SIMILAR CONDITIONS.

F. PROVIDE BACKING FOR ALL BATH ACCESSORIES, HANDRAILS, OR OTHER ITEMS ATTACHED

TO BUILDING WALLS U.O.N., INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

G. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

H. REFER TO FINISH PLAN AND ROOM FINISH SCHEDULE FOR FINISH LOCATIONS.

I. GYPSUM USED IN RESTROOMS SHALL BE WATER RESISTANT GYPSUM BOARD. USE TILE

BACKER BOARD AT ALL PORCELAIN & CERAMIC TILE LOCATIONS.

J. HEIGHT OF OPERATIONAL OR DISPENSING PORTION OF ACCESSORIES & FIXTURES NOT TO

EXCEED 48" A.F.F.

GENERAL ELEVATION NOTES

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

A5077

A5080

M3073

A5075

A5180

A1

AI501

B1

AI501

D1

AI501

1" FILLER

30" 30"

1" FILLER

30" 30"

6.40B

6.40A

6.40D

9.09

12.21

22.01

12.23

6.40E

6.40E 26.01

A1012

A5145A5145

A5107

11.50A

11.50A 6.40B

M4116

50002N

F2000

M3073

A5080

A5075

15"

24"

6.40B

6.40D

6.40A

9.09

12.21

22.01

12.23

11.50A

6.40E

6.40E

A5109

A5075 A5082

A5145

F2010

A5090

A5200

9.09B

9.09A

22.01

22.10A

26.31

A5109A5109

A1067

A5109

A5200

A5090

9.09B

9.09A

22.10A

A5109A5109

A1067

A5082

A5075

F2010

9.09B

9.09A

22.01

26.31

30130E

F0860

B1

AI501

D1

AI501

A1

AI501

1" FILLER

24" 24"

30" 18"

6.60A

6.40B

6.40D

6.40A

9.09

12.21

22.01

12.23

6.40E

6.40E

B1

AI501

D1

AI501

A5080

A5075

K1552

R7250

6.40D

22.01

6.40A

9.09

12.21

11.08

30" 12"

6.40E

A1012

9.09

B1

AI501

A1

AI501

A2

AI501

R7250

K4665K4665

11.08

6.40A

12.21

6.40B

1" FILLER12"27"

27" 12" 1" FILLER

6.40E

6.40E

26.01

11.08

HWC-1.3

A5135

A5080

9.09

22.31

50025N

50026N

CG-2.FCG-2.F

30097E

30118E

30119E

F3200

9.09

CG-1.F

9.089.08

C5

AE501

30097E30097E30097E

30118E30118E

F2000F2000

F2000F2000F2000

A1015A1015A1015

A1015A1015

CG-1.F CG-1.F

9.08

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI403

INTERIOR ELEVATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

KEYNOTES

KEY VALUE KEYNOTE TEXT

6.40A PLASTIC LAMINATE BASE CABINET

6.40B PLASTIC LAMINATE WALL CABINET WITH SLOPED TOP U.O.N.

6.40D PLASTIC LAMINATE SINK ENCLOSURE

6.40E PLASTIC LAMINATE FINISHED END

6.60A SOLID SURFACE WDW SILL, REF. FINISH SCHEDULE

9.08 GWB SOFFIT.

9.09 WALL BASE AS SCHEDULED.

9.09A BASE TILE PT-1.

9.09B WALL TILE PT-2.

11.08 COORDINATE REQUIRED CLEARANCE AT CASEWORK FOR

EQUIPMENT.

11.50A CEILING MOUNTED PATIENT LIFT SYSTEM - 770 LBS CAPACITY.

PARALLEL RAILS RECESSED INTO CEILING. VA SUPPLIED AND

INSTALLED UNDER A SEPARATE CONTRACT. THIS CONTRACTOR TO

COORDINATE LIFT LOCATION W/ MEP ELEMENTS.

12.21 SOLID SURFACE COUNTERTOP.

12.23 1-INCH RADIUS CORNER

22.01 SINK - REF. PLUMBING.

22.10A ADA TOILET - REF. PLUMBING.

22.31 MOP SINK - REF. PLUMBING.

26.01 ELECTRICAL DEVICE, REF. ELECTRICAL.

26.31 LIGHT FIXTURE - SEE ELEC.

1/4" = 1'-0" A1

ELEV - 451 - PT/OT BARIATRIC ROOM - E

1/4" = 1'-0"

A2

ELEV - 451 - PT/OT BARIATRIC ROOM - N

1/4" = 1'-0" A3

ELEV - 462 STAFF TOILET - N

1/4" = 1'-0"

A4

ELEV - 462 STAFF TOILET - W

1/4" = 1'-0" A5

ELEV - 462 STAFF TOILET- E

1/4" = 1'-0" B1

ELEV - 467 CHIEF PM&R EXAM - W

1/4" = 1'-0"

B2

ELEV - 468 BREAK RM - E

1/4" = 1'-0" B3

ELEV - 468 BREAK RM - S

1/4" = 1'-0"

B4

ELEV - 469 HSKPG - W

1/4" = 1'-0" C1

ELEV - 470 MSA CHECK IN - E

1/4" = 1'-0"

C2

ELEV - 470 MSA CHECK IN - S

1x WD. BLOCK'G AS

REQ'D., TYP.

25"

DASHED LINES

REPRESENT OUTLINE

OF ADA CLEARANCE

AND OPEN BOTTOM OF

ENCLOSURE

M

IN

A D

A

A D

A

M

IN

ADA

6" MAX

ADA

11" MIN

/2

/2

1"

HPDL FRONT APRON

ON 3/4" PART. BD. W/

3MM EDGE BANDING

REMOVABLE APRON,

HPDL ON 3/4" PART.

BD. W/ 3MM EDGE

BANDING; CLEAT TO

ADJ. SURFACES.

FAUCET, REF. PLUMB'G

SOLID SURFACE TOP W/ NO-DRIP

EDGE ON 3/4" MARINE GRADE

PLYWD OR MDF & 4"

THERMOFORMED COVED BACK &

SIDE SPLASH W/ EASED TOP

EDGE AND SEAMED

UNDERMOUNT INTEGRAL SINK

(REF. SPEC)

/2

/4

ADA

8" MIN

NO BOTTOM PANEL

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

HPDL FINISH ON PART.

BD, INTERIOR

1x BLOCK'G AS REQ'D

18"

15"

NOTE: RADIUS BOTH

BOTTOM HORIZONTAL

EDGES OF

MICROWAVE CABINET

COORD. OUTLET

LOCATION WITH

ELEC.

VERTICAL BRACING

HPDL ON 3/4" PART

BD SLOPED TOP

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

DISHWASHER FURNISHED

AND INSTALLED BY G.C.

1x WD. BLOCK'G AS

REQ'D. TYP.

25"

SOLID SURFACE TOP W/

SQUARE, EASED EDGE ON

3/4" MARINE GRADE PLYWD

OR MDF & 4" THERMOFORMED

COVED BACK & SIDE SPLASH

W/ EASED TOP EDGE

BASE AS SCHEDULED

FINISHED END OF CABINET

BEYONZD WITH 3MM

EDGE BAND FRONT AND

BOTTOM EDGE

/4

FAUCET, REF. PLUMB'G

24"

3"

/4

PULL TYP., REF. SPEC.

BASE AS SCHEDULED

2x WD. BLOCK'G

AS REQ'D., TYP.

HPDL FINISH ON 3/4" PART.

BD. FALSE DRAWER FRONT

W/ 3MM EDGE BANDING

HPDL FINISH ON 3/4"

PART. BD., EXTERIOR W/

3MM EDGE BANDING

MELAMINE FINISH ON

PART. BD., INTERIOR

1/4" BACK

1x WD. BLOCK'G AS REQ'D., TYP.

LOCK, REF. SPEC., ONLY

WHERE SPECIFIED IN ELEV.

SOLID SURFACE TOP W/

SQUARE, EASED EDGE ON 3/4"

MARINE GRADE PLYWD OR MDF

& 4" THERMOFORMED COVED

BACK & SIDE SPLASH

DROP-IN SINK, REF. PLUMB'G

1" ADJ. SHELVES

SUPPORTED BY 32MM

SYSTEM

MELAMINE FINISH ON

PART. BD., INTERIOR

2x WD. BLOCK'G

AS REQ'D., TYP.

1x WD. BLOCK'G AS

REQ'D., TYP.

1/4" BACK

BASE AS SCHEDULED

PULL, TYP., REF. SPEC.

PULL, TYP., REF. SPEC.

HPDL FINISH ON 3/4"

PART. BD., EXTERIOR

OTHERWISE NOTED IN ELEV.

24" - UNLESS

3"

LOCK WHERE SHOWN ON

ELEVS, REF SPEC, TYP.

R E

F E

L E

V A

T

IO

N S

25"

/4

SOLID SURFACE TOP W/

SQUARE, EASED EDGE

ON 3/4" PLYWD OR MDF &

4" THERMOFORMED

COVED BACK & SIDE

SPLASH W/ TOP EASED

EDGE

REF ARCH DWGS FOR WALL

CONSTRUCTION

PLAN VIEW LINE OF COUNTERTOP AND

APRON BELOW

LAVATORY CARRIER EQUAL TO

ZURN Z1236 (SIZE LENGTH TO C-

TOP DEPTH), REF PLUMB'G SPEC

& COORDINATE W/ GENERAL

CONTRACTOR; PAINT EXPOSED

SURFACES TO MATCH ADJ WALL.

COORDINATE W/ INSTALLATION

OF MILLWORK.

SECTION VIEW

DROP-IN SINK, REF. PLUMB'G

DRAWINGS

LAVATORY CARRIER EQUAL TO ZURN

Z1236 (SIZE LENGTH TO C-TOP DEPTH),

REF PLUMB'G SPEC & COORDINATE W/

GENERAL CONTRACTOR; PAINT

EXPOSED SURFACES TO MATCH ADJ

WALL. COORDINATE W/ INSTALLATION

OF MILLWORK; SECURELY FASTEN

CARRIER TO C-TOP SUBSTRATE.

INSTALL ADDITIONAL 3/4"

SUBSTRATE LAYER AT CARRIER

ARMS & SECURELY FASTEN

1x WD. BLOCK'G AS REQ'D., TYP.

25"

DASHED LINES REPRESENT

OUTLINE OF ADA CLEARANCE AND

OPEN BOTTOM OF ENCLOSURE

/4

/4

M

IN

A D

A

A D

A

M

IN

ADA

6" MAX

ADA

11" MIN

NOTE: PROVIDE FINISHED END

PANELS WHEN SIDES ARE EXPOSED

1"

HPDL FRONT APRON ON 3/4"

PART. BD. W/ 3MM EDGE

BANDING

REMOVABLE APRON, HPDL ON 3/4"

PART. BD. W/ 3MM EDGE BANDING;

CLEAT TO ADJ. SURFACES.

FAUCET, REF. PLUMB'G

SOLID SURFACE TOP W/ SQUARE,

EASED EDGE ON 3/4" MR PLYWD OR

MDF & 4" THERMOFORMED BACK &

SIDE SPLASH W/ EASED TOP EDGE

NO BOTTOM PANEL

****NOTE: WALL CARRIER ONLY WHERE SINK

IS ON EXPOSED END. USE WALL BLOCKING

OTHERWISE****

DROP-IN SINK, REF. PLUMB'G

ADA

8" MIN

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

VERTICAL BRACING

HPDL ON 3/4" PART

BD SLOPED TOP

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE CONSTRUCTION

DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

BEFORE PROCEEDING WITH THE WORK.

B. COORDINATE DEVICE PENETRATIONS AT COUNTERTOPS W/ MECHANICAL & ELECTRICAL.

C. COORDINATE CASEWORK WITH EQUIPMENT LOCATED WITHIN, ON, OR ADJACENT TO

CASEWORK, INCLUDING ITEMS FURNISHED AND/OR INSTALLED BY OTHERS.

D. PROVIDE COUNTERTOP SUPPORTS AT ALL OPEN SPACES APPROXIMATELY 3'-0" O.C. MAX.

BRACKETS TO BE PAINTED TO MATCH SPECIFIED WALL FINISH.

E. PROVIDE FINISHED END PANELS AT ALL EXPOSED MILLWORK SURFACES. ALL PLAM

CABINETS TO HAVE PVC EDGES U.O.N. MATCH PVC EDGE TO PLAM. SUBMIT SAMPLES FOR

APPROVAL.

F. PROVIDE 4" RESILIENT BASE AT ALL BASE CABINETS (UON).

G. MILLWORK SUPPLIER SHALL PROVIDE FILLER PANELS & SCRIBE STRIPS WHERE NEEDED

FOR COMPLETE INSTALLATION.

H. CABINETS OVER 30" WIDE SHALL HAVE 1" THICK PARTICLE BOARD CORE.

I. SEAL ALL EXPOSED WOOD, INCLUDING COUNTERTOP SUBSTRATES.

J. DO NOT PROVIDE SIDESPLASH UNLESS OTHERWISE NOTED.

K. UNLESS OTHERWISE INDICATED, PROVIDE PRODUCTS OF QUALITY SPECIFIED BY AWI

ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR PREMIUM GRADE.

L. REFER TO MATERIAL & COLOR SCHEDULE FOR COLOR SELECTIONS.

M. INSTALL BACKING AS REQUIRED IN ALL PARTITIONS TO RECEIVE COUNTERS, SHELVING, ETC.

N. REFER TO ELEVATIONS FOR CABINET LOCK LOCATIONS.

O. VERIFY ALL GROMMET LOCATIONS AND QUANTITIES WITH OWNER.

GENERAL CASEWORK NOTES

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

NOTE: SIDE PANELS TO BE ONE FULL

HT PIECE ON EXPOSED ENDS

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

3/4" SCRIBE

FACE OF SOFFIT

17"

15"

R E

F E

L E

V

BLANK PANEL - ALIGN

WITH ADJACENT

CABINET AND SCRIBE.

HOOD CABINET HAS

OPEN TOP, BOTTOM &

BACK. HPDL FINISH ON

3/4" PART. BD

FACE OF SOFFIT

17"

HOOD AND DUCT;

REF. MECHANICAL

FINISHED END OF

CABINET BEYOND

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

1" ADJ. SHELVES

SUPPORTED BY

32MM SYSTEM

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

15"

R E

F E

L E

V A

T

IO

N S

LOCK, REF. SPEC.,

ONLY WHERE

SPECIFIED IN ELEV.

3/4" SCRIBE

ACOUSTICAL CEILING

TILE, REF. SPECS.

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x WD. BLOCK'G AS REQ'D., TYP.

25"

/4

1" HPDL FRONT APRON ON 3/4"

PART. BD. W/ 3MM EDGE

BANDING

FAUCET, REF. PLUMB'G

SOLID SURFACE TOP W/ SQUARE,

EASED EDGE ON 3/4" MR PLYWD OR

MDF & 4" THERMOFORMED BACK &

SIDE SPLASH W/ EASED TOP EDGE

DROP-IN SINK, REF. PLUMB'G

PLASTER TRAP, REF. PLUMB'G

PULL, TYP.

MELAMINE FINISH ON

PART. BD., INTERIOR

HPDL FINISH ON 3/4"

PART. BD, EXTERIOR

1x BLOCK'G AS REQ'D

COORD W/ PT LIFT

12"

LOCK

C O

O R

D W

P

T L

IF

T

OPEN TOP FOR

PATIENT LIFT

ACOUSTICAL CEILING

TILE, REF. SPECS.

1x WD. BLOCK'G AS REQ'D., TYP.

25"

DASHED LINES REPRESENT

OUTLINE OF ADA CLEARANCE

AND OPEN BOTTOM OF

ENCLOSURE

M

IN

A D

A

A D

A

M

IN

ADA

6" MAX

ADA

11" MIN

/2

/2

1"

HPDL FRONT APRON ON 3/4"

PART. BD. W/ 3MM EDGE

BANDING

REMOVABLE APRON, HPDL ON 3/4"

PART. BD. W/ 3MM EDGE BANDING;

CLEAT TO ADJ. SURFACES.

FAUCET, REF. PLUMB'G

SOLID SURFACE TOP W/ NO-DRIP

EDGE ON 3/4" MARINE GRADE

PLYWD OR MDF & 4"

THERMOFORMED COVED BACK &

SIDE SPLASH W/ EASED TOP

EDGE AND SEAMED

UNDERMOUNT INTEGRAL SINK

(REF. SPEC)

/2

/4

ADA

8" MIN

NO BOTTOM PANEL

LAVATORY CARRIER EQUAL TO ZURN

Z1236 (SIZE LENGTH TO C-TOP DEPTH),

REF PLUMB'G SPEC & COORDINATE W/

GENERAL CONTRACTOR; PAINT

EXPOSED SURFACES TO MATCH ADJ

WALL. COORDINATE W/ INSTALLATION

OF MILLWORK; SECURELY FASTEN

CARRIER TO C-TOP SUBSTRATE.

NOTE: PROVIDE FINISHED END

PANELS WHEN SIDES ARE EXPOSED

PLAN VIEW

LAVATORY CARRIER EQUAL TO

ZURN Z1236 (SIZE LENGTH TO C-

TOP DEPTH), REF PLUMB'G SPEC

& COORDINATE W/ GENERAL

CONTRACTOR; PAINT EXPOSED

SURFACES TO MATCH ADJ WALL.

COORDINATE W/ INSTALLATION

OF MILLWORK.

SEAMED UNDERMOUNT

INTEGRAL SINK (REF. SPEC)

INSTALL ADDITIONAL 3/4"

SUBSTRATE LAYER AT CARRIER

ARMS & SECURELY FASTEN

****NOTE: WALL CARRIER ONLY WHERE SINK

IS ON EXPOSED END. USE WALL BLOCKING

OTHERWISE****

LINE OF COUNTERTOP AND

APRON BELOW

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI501

MILLWORK SECTION DETAILS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

1" = 1'-0" B2

SECTION - LAVATORY

1" = 1'-0" A2

SECTION - MW WALL CABINET

1" = 1'-0" B4

SECTION - COUNTER AT TRAINING DW

1" = 1'-0"

B3

SECTION - SINK CABINET AT TRAINING

1" = 1'-0" B1

SECTION - TYPICAL BASE CABINET

1" = 1'-0" D1

SECTION - TYPICAL SINK ENCLOSURE

1" = 1'-0" A1

SECTION - TYPICAL WALL CABINET

1" = 1'-0"

A3

SECTION - WALL CABINET AT SOFFIT

1" = 1'-0" A4

SECTION - WALL CABINET AT HOOD

1" = 1'-0"

A5

SECTION - WALL CABINET AT PLASTER

1" = 1'-0" D3

SECTION - SINK AT PLASTER TRAP

1" = 1'-0" B5

SECTION - WALL CABINET AT PATIENT LIFT

1" = 1'-0" D2

SECTION - LAVATORY AT TRAINING

SIGNAGE NOTES

1. SIGN LOCATION ID DISTINGUISHED WITH SIGN TAG NUMBER EQUAL TO THE ROOM NUMBER AND SIGN TYPE (EX: A313-P)

2. REFERENCE GRAPHICAL SIGN ILLUSTRATIONS FOR SIGNAGE REQUIRING ROOM NUMBERS.

3. VA, ARCHITECT, CONTRACTOR, AND SIGNAGE SUPPLIER TO MEET AND AGREE ON SIGNAGE COPY/MESSAGE/TEXT PRIOR TO SIGNAGE SUBMITTAL

DOCUMENTS FOR APPROVAL.

4. SIGNAGE SUBMITTAL TO INCLUDE VISUAL GRAPHIC OF EACH INDIVIDUAL SIGN IN PROJECT.

5. WALL MOUNTED SIGNS TO BE MECHANICALLY FASTENED TO WALL.

6. SIGNAGE DESIGN AND MATERIALS TO MATCH EXISTING HSTVA SIGNAGE STANDARDS, REF SPEC.

7. ALL SIGNAGE TO BE IN COMPLIANCE WITH ADA & ABA ACCESSIBILITY STANDARDS FOR FEDERAL FACILITIES.

8. SQUARE SATIN ANODIZED ALUMINUM FRAME.

9. SIGN COMPANY TO PURCHASE ALL GRAPHIC IMAGES FOR THE HOSPITAL. SIGN COMPANY RESPONSIBLE FOR MODIFYING BACKGROUND ON IMAGES.

10. SIGN COMPANY TO PROVIDE OWNER WITH SOFTWARE, PRINTER, MATERIALS & INSTRUCTIONAL CLASS ON HOW TO UPDATE CHANGEABLE SIGNS.

11. SIGN COMPANY TO PROVIDE DISC OF TEMPLATE LAYOUT DRAWINGS, COLOR, AND TYPOGRAPHY SPECS FOR ALL CHANGEABLE SIGNS INCLUDING DIRECTORY, DIRECTIONALS, AND OVERHEADS.

12. SIGNAGE INSTALLER TO COORDINATE LOCATIONS OF CEILING HUNG SIGNS WITH FIRE PROTECTION SPRINKLER HEADS ACCORDING TO NFPA REGULATIONS.

13. SIGNAGE MOUNTED TO GLASS SHALL HAVE BLANK FACE PLATE ON OPPOSITE SIDE TO CONCEAL ATTACHMENT METHOD.

/4

39 1/4"

/8

LIGHT BLUE

2” SILVER HELVETICA BOLD CONDENSED

VINYL LETTERS

DARK BLUE

SQUARE SATIN SILVER ANODIZED

ALUMINUM FRAME WITH 75%

RECYCLED CONTENT WITH

FLEXIBLE CLEAR LENS COVER

DIGITALLY PRINTED

BACKGROUND AND ACCENT

VA Verify Text

1/8" 1" 4" 1" EQ CENTER TITLE TEXT EQ 1/8"

E Q

E Q

4” SILVER & DARK BLUE

VINYL CIRCLE W/ CHEVRON ARROW

SEE SIGNAGE SCHEDULE FOR

ARROW DIRECTION

FRONT VIEW - LOWER ACRYLIC PLAQUE

CLEAR FACE DIMENSIONS

3/8" 8 1/4" 3/8"

Waiting Room

/2

/2

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI601

SIGNAGE SCHEDULE AND DETAILS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

SIGNAGE SCHEDULE

ARCH.

ROOM

NUMBER ARCH. ROOM NAME

SIGN

TYPE SIGN TYPE DESCRIPTION

SIGN

NUMBER

MOUNTING

SURFACE SIGN COPY SINGLE-SIDED/SIDE A SIGN COPY SIDE B NOTES

400 ELEV. LOBBY/CORR. E2 DIRECTIONAL CEILING 400-E2 CEILING PROSTHETICS PROSTHETICS A: RIGHT ARROW

B: LEFT ARROW

400 ELEV. LOBBY/CORR. F FIRE EXTINGUISHER 400-F FLAG/WALL REFERENCE LEGEND FOR COPY

400 ELEV. LOBBY/CORR. F1 2 PANEL DIRECTIONAL 400-F1 WALL REINSTALL EXISTING SIGN

400 ELEV. LOBBY/CORR. H SMALL DIRECTORY 400-H WALL REINSTALL EXISTING SIGN

401 ELEV. LOBBY R.1 ROOM SIGN 401-R.1 WALL

401A SOILED DISP A AUTHORIZED ONLY 401A-A DOOR REFERENCE LEGEND FOR COPY

401A SOILED DISP R ROOM SIGN 401A-R WALL SOILED

402 WOMEN'S TLT B.1 RESTROOM 402-B.1 WALL REFERENCE LEGEND FOR COPY

402 WOMEN'S TLT E.1 RESTROOM FLAG 402-E.1 FLAG/WALL REFERENCE LEGEND FOR COPY

402 WOMEN'S TLT K BABY CHANGING 402-K WALL REFERENCE LEGEND FOR COPY

403 MEN'S TLT B.1 RESTROOM 403-B.1 WALL REFERENCE LEGEND FOR COPY

403 MEN'S TLT E.1 RESTROOM FLAG 403-E.1 FLAG/WALL

403 MEN'S TLT K BABY CHANGING 403-K WALL REFERENCE LEGEND FOR COPY

404 WC STOR./SHOP R ROOM SIGN 404-R WALL WHEELCHAIR STORAGE

404 WC STOR./SHOP R ROOM SIGN 404-R WALL WHEELCHAIR STORAGE

404A STG. R.1 ROOM SIGN 404A-R.1 WALL

405 PROST. STOCK RM. R ROOM SIGN 405-R WALL PROSTHETICS STOCK ROOM

405 PROST. STOCK RM. R ROOM SIGN 405-R WALL PROSTHETICS STOCK ROOM

405A PROST. CHECKIN R ROOM SIGN 405A-R WALL PROTHETICS CHECK-IN

410 PROST. WAIT. R ROOM SIGN WAIT 410-R WALL REFERENCE DETAIL FOR COPY

411 FITTING/EXAM RM. R ROOM SIGN 411-R WALL FITTING/EXAM 1

412 STAIR #2 G RACE FIRE 412-G DOOR REFERENCE LEGEND FOR COPY

412 FITTING/EXAM RM. R ROOM SIGN 412-R WALL FITTING/EXAM 2

412 STAIR #2 S STAIR FLAG 412-S FLAG/WALL STAIR 2 REFERENCE LEGEND FOR COPY

412 STAIR #2 S.1 STAIR 412-S.1 DOOR STAIR 2 EXISTING REMAINS

413 PROST. PURCHASING R ROOM SIGN 413-R WALL OFFICE

414 STAFF TLT. B RESTROOM 414-B WALL REFERENCE LEGEND FOR COPY

414 STAFF TLT. E RESTROOM FLAG 414-E FLAG/WALL REFERENCE LEGEND FOR COPY

415 PROST. REP R ROOM SIGN 415-R WALL PROSTHETICS REPRESENTATIVE

416 PROST. CHIEF R ROOM SIGN 416-R WALL PROSTHETICS CHIEF

417 PROST. ASST. CHIEF R ROOM SIGN 417-R WALL PROSTHETICS ASSISTANT CHIEF

418 ELEC. R.1 ROOM SIGN 418-R.1 WALL

419 FITTING/EXAM RM. R ROOM SIGN 419-R WALL FITTING/EXAM 3

420 ANTE A AUTHORIZED ONLY 420-A DOOR REFERENCE LEGEND FOR COPY

420 ANTE R ROOM SIGN 420-R WALL PROSTHETICS LAB

421 DUST RM. R ROOM SIGN 421-R WALL DUST ROOM

421A MAINT. R ROOM SIGN 421A-R WALL MECHANICAL

422 FUME RM. R ROOM SIGN 422-R WALL FUME ROOM

423 PLASTER R ROOM SIGN 423-R WALL PLASTER ROOM

424 CLEAN LAB G EYE WASH 424-G FLAG/WALL REFERENCE LEGEND FOR COPY

424 CLEAN LAB R ROOM SIGN 424-R WALL CLEAN LAB

425 PER. CLNC. GROUP RM. R ROOM SIGN 425-R WALL GROUP ROOM 2

426 PER. CLNC. MASSAGE R ROOM SIGN 426-R WALL GROUP ROOM 1

426A STOR. R ROOM SIGN 426A-R WALL STORAGE

430 CHIRO. EXAM R ROOM SIGN 430-R WALL CHIROPRACTIC EXAM 1

431 CHIRO. EXAM R ROOM SIGN 431-R WALL CHIROPRACTIC EXAM 2

432 ACUPUNCTURE R ROOM SIGN 432-R WALL ACUPUNCTURE EXAM 1

433 ACUPUNCTURE R ROOM SIGN 433-R WALL ACUPUNCTURE EXAM 2

434 PELVIC R ROOM SIGN 434-R WALL PELVIC EXAM 1

435 PELVIC R ROOM SIGN 435-R WALL PELVIC EXAM 2

436 PT/OT EXAM R ROOM SIGN 436-R WALL PT/OT EXAM 1

437 PT TLT. B RESTROOM 437-B WALL REFERENCE LEGEND FOR COPY

437 PT TLT. E RESTROOM FLAG 437-E FLAG/WALL REFERENCE LEGEND FOR COPY

438 PT/OT EXAM R ROOM SIGN 438-R WALL PT/OT EXAM 2

439A CLO. R.1 ROOM SIGN 439A-R.1 DOOR

440 OT TRAIN. RM. R ROOM SIGN 440-R WALL OT TRAINING

440A OT TLT. R ROOM SIGN 440A-R WALL OT TOILET

447 STAIR #1 S STAIR FLAG 447-S FLAG/WALL STAIR 1 REFERENCE LEGEND FOR COPY

447 STAIR #1 S.1 STAIR 447-S.1 WALL STAIR 1 REFERENCE LEGEND FOR COPY

450 PT GYM C CRASH CART 450-C FLAG/WALL REFERENCE LEGEND FOR COPY

450 PT GYM F FIRE EXTINGUISHER 450-F FLAG/WALL REFERENCE LEGEND FOR COPY

450 PT GYM R ROOM SIGN 450-R WALL PT/OT GYM

450 PT GYM R ROOM SIGN 450-R WALL PT/OT GYM

450A CLEAN LINEN R ROOM SIGN 450A-R WALL CLEAN LINEN

451 PT/OT EXAM BARIATRIC R ROOM SIGN 451-R WALL PT/OT EXAM 3

452 PT/OT STOR. R ROOM SIGN 452-R WALL STORAGE

453 ELEC. R.1 ROOM SIGN 453-R.1 WALL

455 WAIT. R ROOM SIGN WAIT 455-R WALL REFERENCE DETAIL FOR COPY

460 PT/OT SWAMP A AUTHORIZED ONLY 460-A DOOR REFERENCE LEGEND FOR COPY

460 PT/OT SWAMP A AUTHORIZED ONLY 460-A DOOR REFERENCE LEGEND FOR COPY

460 PT/OT SWAMP R ROOM SIGN 460-R WALL OP/PT SWAMP

460 PT/OT…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .