Drawings-589A4-22-100-2023-02-15 BID Set - Part3-pages-12.pdf
PDF 5 MB Posted
- Solicitation number
- 36C25523R0072
About this file
This set of construction documents includes plans and specifications for renovating the fourth floor at a Department of Veterans Affairs medical center to relocate physical medicine and rehabilitation services. The project involves remodeling existing spaces and constructing new walls, floors, ceilings, doors and other features. Key products and services required include operable partitions, gait training equipment, medical equipment, furniture and various other items detailed in the equipment schedule. Construction will be carried out according to the specifications governing materials, systems and quality of work. The solicitation information provided indicates this project is publicly advertised for competitive bidding under solicitation number 36C25523R0072 with an agency point of contact and estimated completion date.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F E
C
F E
C
FEC
FOURTH FLOOR KEY PLAN
AREA A
N
B
A
NOTES:
WALL HEIGHT
SHADED WALLS INDICATE WALLS
THAT EXTEND TO DECK
WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH FACES
OF METAL STUD AND WALLS THAT REQUIRE ACOUSTICAL SOUND
BATT INSULATION SHALL BE CONSTRUCTED TO MEET A MINIMUM
45 STC UNLESS OTHERWISE NOTED.
ALL STUD FRAMING TO BE 16" O.C., TYP.
LIGHT GAUGE METAL STUDS, 20GA/19MIL TYP. (16GA AT TOILET
ROOM PLUMBING WALLS & SHOWER SEAT WALLS) (REF. SPECS.)
PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL
SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL
TILE. TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT
GYP BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND
GA-216.
PROVIDE ACOUSTICAL SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS OF WALLS WITH SOUND BATT.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF
SMOKE PARTITION WALLS AS REQUIRED BY CODE - REF. SPECS.
PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2" MTL.
DEFLECTION TRACK - REF STRUCT.
BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C. OR
EXTEND ALL STUDS TO DECK ABOVE, TYP.
INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS, GAPS
AND TOP & BOTTOM OF FRAMING AS REQUIRED BY CODE - REF.
SPEC.
INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING, TYP.
INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF STUD FRAMING,
TYP., UNLESS NOTED OTHERWISE.
EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED
OTHERWISE.
PROVIDE 20GA DOUBLE STUDS FULL HEIGHT AT ALL INTERIOR
DOOR JAMBS.
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE
CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
AND THE OWNER BEFORE PROCEEDING WITH THE WORK.
B. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBENT SURFACES WITH A SUITABLE DILUTED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
COORDINATE WITH MANUFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
C. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
D. ITEMS/EQUIPMENT IN LIGHT GRAY ( ) ARE FOR REFERENCE ONLY.
E. ALL DIMENSIONS ARE TO FACE OF STUDS U.N.O.
F. ALL SPOT ELEVATIONS ARE TO FINISH FLOOR U.N.O
GENERAL PLAN NOTES
4.5
5.4
6.2
F.1GHJ
KLMa La
Jb Hb Ga
PROST.
CHIEF
PROST. REP
PROST.
ASST. CHIEF
PLASTER
CLEAN LAB
FUME RM.
STAFF TLT.
FITTING/EXAM
RM.
MAINT.
421A
DUST RM.
PER. CLNC.
MASSAGE
PER. CLNC.
GROUP RM.
FITTING/EXAM
RM.
FITTING/EXAM
RM.
PROST.
PURCHASING
PROST.
WAIT.
HSKPG.
CHIRO. EXAM
CHIRO. EXAM
PELVIC
ACUPUNCTURE
PROST.
STOCK RM.
ELEV. LOBBY
/ CORR.
ELEV. LOBBY
WC
STOR./SHOP
WAIT.
CORR.
C41
MSA
CHECKIN/OUT
WOMEN'S
TLT
MEN'S TLT
BREAK RM.
F2
P31
F2F2 P31
F2 F3
F3
6.7
F2
P3
P3
F2
P3
P3
P6
P31
P31P31
P31P31
P31
P31
P3
P3
P3
P31 F2F2
P3
P3
P3
P3
P31
P3
P3 F2
P3
F2
P3
P3
P3
P3
P3
F3
F3
P3
F2F2 F3F3 F2
F2F2
F2
P3
F2F2 F2
F3
F2F2
F2
C L R
F
IN
F2F2
F2F2
F2
F2
F2F2
F2F2
F2
S21
F3
F3
F2F2
F2
F2 F2F2
F2
/2
F3
F2 F2F2
F0
F3F3
F3
F2
F2F2F2
S21F2
F3F3F3
F2F2
F2
F3
F2
F6
F2
F1
CLR FIN
6' - 0"
F3
S21S21
F3
P3
CORR.
C42
8.33
8.33
P3
F2
F6
F2
CLR
1' - 7"
6' - 3 1/2"
1' - 5 3/8"
C L R
F
IN
C L R
2' - 6"
C L R
/4
/8
/4
C L R
F
IN
CLR
6' - 0"
C L R
C L R
6 1/4" 3' - 5"
8 7/8" 7' - 3 7/8" 6' - 4 7/8"
CLR
6' - 0"
/8
CLR FIN
6' - 0"
1' - 4 5/8"
7' - 5 1/2"
C L R
F
IN
1' - 8 1/4"
C3
C3
P3
P6
P3
P3 P3
F2
P3
F3
F3
C3 P3P3
F3
F3
F3
P3P3
P3
P3
1' - 0 1/2" 6' - 4 7/8"
8' - 10 7/8" 8' - 11" 10' - 4 5/8" 13' - 9" 3' - 11"
/4
F2 P3
/4
C L R
F
IN
/8
/4
F2
P3
/8
/4
F2
13' - 3 1/4"
AE401
A1
SIM
AE401
D1
SIM
AE401
A2
SIM
ALIGN
ALIGN
8.078.07
PROST.
CHECKIN
405A
SOILED DISP
401A
CORR.
C43
1.01
F2
P3
P31
P3
D6
AE501
D6
AE501
B6
AE501
SIM
B6
AE501
SIM
B6
AE501
SIM
1.01
1.01
1.01
22.47
10.40
10.40
8.04A
11' - 2"
F2
11' - 2 1/8"
P31
AE501
D4
1.01
22.34
TYPE F - FURRING
F0 7/8" HAT CHANNEL, 5/8" G.W.B. 1 1/2"
F1 1 5/8" MTL STUD, 5/8" G.W.B. 2 1/4"
F2 2 1/2" MTL STUD, 5/8" G.W.B. 3 1/8"
F3 3 5/8" MTL STUD, 5/8" G.W.B. 4 1/4"
F6 6" MTL STUD, 5/8" G.W.B. 6 5/8"
FS2 2 1/2" 16GA MTL STUD, 5/8" G.W.B. 3 1/8"
FS3 3 5/8" 16GA MTL STUD, 5/8" G.W.B. 4 1/4"
FS6 6" 16GA MTL STUD, 5/8" G.W.B. 6 5/8"
F8 8" MTL STUD, 5/8" G.W.B. 8 5/8"
TYPE P - PARTITION
P3 5/8" G.W.B, 3 5/8" MTL STUD, 5/8" G.W.B. 4 7/8"
P31 5/8" G.W.B, 3 5/8" MTL STUD, 5/8" G.W.B. (1 HR RATED) 4 7/8"
P32 (2) 5/8" G.W.B, 3 5/8" MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 6 1/8"
P6 5/8" G.W.B, 6" MTL STUD, 5/8" G.W.B. 7 1/4"
P61 5/8" G.W.B, 6" MTL STUD, 5/8" G.W.B. (1 HR RATED) 7 1/4"
P8 5/8" G.W.B, 8" MTL STUD, 5/8" G.W.B. 9 1/4"
PS3 5/8" G.W.B, 3 5/8" 16GA MTL STUD, 5/8" G.W.B. 4 7/8"
PS31 5/8" G.W.B, 3 5/8" 16GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 4 7/8"
PS32 (2) 5/8" G.W.B, 3 5/8" 16 GA MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 6 1/8"
PS6 5/8" G.W.B, 6" 16GA MTL STUD, 5/8" G.W.B. 7 1/4"
PS61 5/8" G.W.B, 6" 16GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 7 1/4"
PS62 (2) 5/8" G.W.B, 6" 16GA MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 8 1/2"
PS8 5/8" G.W.B, 8" 16 GA MTL STUD, 5/8" G.W.B. 9 1/4"
PS81 5/8" G.W.B, 8" 16 GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 9 1/4"
EXISTING WALL
HAT CHANNEL
OR MTL STUD
5/8" TYPE "X" G.W.B.
5/8" TYPE "X" G.W.B.
(2 LAYERS @ 2 HR RATED)
MTL STUD
5/8" TYPE "X" G.W.B.
(2 LAYERS @ 2 HR RATED)
SAFB INSULATION,
FILL CAVITY
SAFB INSULATION,
FILL CAVITY
LEGEND FOR WALL TAGS
PARTITION GROUP DESIGNATOR
HAT CHANNEL, STUD OR CMU SIZEXXX
RATING (IF APPLIES)
UNDERSIDE OF STRUCTURE UNDERSIDE OF STRUCTURE
ACOUSTICAL SEALANT ACOUSTICAL SEALANT @ NON-RATED
WALLS. FIRE SEALANT @ RATED WALLS
DEFLECTION TRACK
DEFLECTION TRACK
ACOUSTICAL SEALANT
WALL BASE AS SCHED.
BASE BASE
METAL CHANNEL
ACOUSTICAL SEALANT @ NON-RATED
WALLS. FIRE SEALANT @ RATED WALLS
WALL BASE AS SCHED.
METAL CHANNEL
TYPE WALL MATERIALS
WALL
WIDTH TYPE WALL MATERIALS
WALL
WIDTH
PLAN
HEAD
PLAN
HEAD
TYPE S - SHAFT
S21 5/8" G.W.B, 2 1/2" C-H STUDS, 1" G.W.B (1 HR RATED) 3 1/8"
S41 5/8" G.W.B, 4" C-H STUDS, 1" G.W.B (1 HR RATED) 4 5/8"
S42 (2) 5/8" G.W.B, 4" C-H STUDS, 1" G.W.B (2 HR RATED) 4 5/8"
5/8" TYPE "X" G.W.B.
C-H MTL STUD
1" TYPE "X" G.W.B.
SAFB INSULATION,
FILL CAVITY
UNDERSIDE OF STRUCTURE
FIRE SEALANT
DEFLECTION TRACK
BASE
FIRE SEALANT
WALL BASE AS SCHED.
METAL CHANNEL
TYPE WALL MATERIALS
PLAN
HEAD
WALL
WIDTHUL
U465 U465
U465
U465 U465
U465 U465
U465
UL
U415 U415 U415
TYPE C - CHASE
(2)5/8" G.W.B, 3 5/8" MTL STUD, 1" AIR, 3 5/8" MTL STUD,
(2)5/8" G.W.B
TYPE WALL MATERIALS
WALL
WIDTH UL
U49310 3/4"C3
5/8" TYPE "X" G.W.B.
(2 LAYERS)
MTL STUD
5/8" TYPE "X" G.W.B.
(2 LAYERS)
SAFB INSULATION,
FILL CAVITY
UNDERSIDE OF STRUCTURE
ACOUSTICAL SEALANT
DEFLECTION TRACK
BASE
ACOUSTICAL SEALANT
WALL BASE AS SCHED.
METAL CHANNEL
PLAN
HEAD
SCOPE OF WORK LEGEND
SHADED AREA NOT IN SCOPE OF WORK
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig h th in c o n e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e rs e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e s e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE104
FLOOR PLAN - DIMENSIONS - 4TH
FLOOR - AREA A
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
KEYNOTES
KEY VALUE KEYNOTE TEXT
1.01 GC TO VERIFY THE RATING OF EXISTING WALL AND UTILIZE ANY MEASURES
NECESSARY TO MAKE IT 1-HR RATED.
8.04A 24"X24" RATED ACCESS DOOR, REF. LIFE SAFETY PLANS FOR REQUIRED RATING,
"BEST CORE" LOCK BY DOOR HARDWARE SUPPLIER.
8.07 OPERABLE PARTITIONS W/ BUILT-IN DOOR, REF. SPECS.
8.33 ROLL UP SECURITY GRILLE, REF. SPECS.
10.40 FULLY RECESSED F.E.C.
22.34 FLOOR DRAIN, REF. PLUMBING.
22.47 BI-LEVEL ADA DRINKING FOUNTAIN W/ BOTTLE FILLING STATION, REF. PLUMBING.
3/16" = 1'-0" D2
4TH FLOOR - DIMENSIONS - AREA A
0' 2'-8" 5'-4" 10'-8"
N
# Revision Date
C
F E
C
F E
C
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE
CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
AND THE OWNER BEFORE PROCEEDING WITH THE WORK.
B. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBENT SURFACES WITH A SUITABLE DILUTED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
COORDINATE WITH MANUFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
C. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
D. ITEMS/EQUIPMENT IN LIGHT GRAY ( ) ARE FOR REFERENCE ONLY.
E. ALL DIMENSIONS ARE TO FACE OF STUDS U.N.O.
F. ALL SPOT ELEVATIONS ARE TO FINISH FLOOR U.N.O
GENERAL PLAN NOTES
FOURTH FLOOR KEY PLAN
AREA B
N
B
A
F
F.1GHJKLMMa La Jb Hb Ga
CHIEF PM&R
EXAM
BREAK RM.
AO
OT SUPER.
REHAB.
COOR.
STAFF TLT.
PSA
PT/OT
SWAMP
PT/OT
SWAMP
PT GYM
PT GYM
WC
STOR./SHOP
WAIT.
455 ELEV. LOBBY
SOILED DISP
401A
PROST.
STOCK RM.
PELVIC
PELVIC
PT TLT.
EQUIP.
CORR.
C44
OT TRAIN.
RM.
OT TLT.
440A
PT/OT EXAM
PT/OT EXAM
ACUPUNCTURE
ACUPUNCTURE
CHIRO. EXAM
PT/OT STOR.
PT/OT EXAM
BARIATRIC
CLEAN LINEN
450A
CRASH CART
ALCOVE
ELEC.
TELE
HEALTH
6.7
F2F2
P3
F2
F2
P3
P3
F2F2
F3F3
P6
F2F2
F2F2
F2
F2F2
F2
F2
F8
F2
F2
F2F2
F2
F2F2
F2
F2F2
F2
P3
P31
P31
P31
F2F2
F2
F3
F3F3F2
P31
P31 P31
F2
F2F2
P31
P31
F2
F2
F3F3
P31
F2
F3
F3F3
F2F2
F2F2
F2
F3F3
P3P3
F2 F3 F2 F2
F2
F1
PS3
F2F2F2 F3F3F3
P31 P3
P3
P3
P3
F2
P3
P31
F3
P31
F2 F3F3
F2F2F2 F2F2F2 F2F2F2 F2F2F2 F3F3F3 F3F3F3 F3F3F3 F3F3F3 F3F3F3
F2
F3
F2
1' - 9 1/8"
F2
F2
F2
F3
F2
F3
F3
F2
F2
F2
F2
P3
CORR.
C42
CORR.
C43
W1
W2
W3
F2
P3
F2
F2F2
PROST.
CHECKIN
405A
2' - 3"
6 1/4" 3' - 6 1/8"
CLR FIN
6' - 0"
C L R
CLR FIN
6' - 0"
C L R
4' - 0 3/8"
/2
/8
/2
CLR FIN
6' - 0"
14' - 6" 12' - 3"
3' - 0"
4' - 5 3/8"
C L R
5' - 2 7/8"
1' - 11 3/4"
7' - 1"
C L R
9 5/8"
C L R
C L R
C L R
/8
C L R
P3 P31
PS3
F3
F2F3
/4
/8
/8
/8
/8
/8
P3
13' - 3 1/4" 22' - 5 5/8"
CLR FIN
6' - 0"
/8
S21
S21
P31 P31
P3
P3
P3
P3
C L R
P3
F2
/8
6' - 4 7/8" 12' - 3 1/4"
CLR
1' - 7"
P31
P31
P3
P3
P6
P6
P31
2' - 6"
P31
F2 F3
F2
AE401
A3
SIM
P3
AE401
C6
SIM
AE401
B3
SIM
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
ALIGN
P31
P31
P31
P3
8.33
P31 S21P3S21 P31P31
S21
S21
S21
1.01
1.01
1.011.01
1.01
STG.
404A
ALIGN
D6
AE501
D6
AE501
B6
AE501
________ B6
AE501
SIM
B6
AE501
SIM
B6
AE501
SIM
1.011.01
1.01
1.01
22.47
10.40
10.40
8.04A
/4
P31
P31
PS3
P31
F0
S21
CLO.
439A
22.34
TYPE F - FURRING
F0 7/8" HAT CHANNEL, 5/8" G.W.B. 1 1/2"
F1 1 5/8" MTL STUD, 5/8" G.W.B. 2 1/4"
F2 2 1/2" MTL STUD, 5/8" G.W.B. 3 1/8"
F3 3 5/8" MTL STUD, 5/8" G.W.B. 4 1/4"
F6 6" MTL STUD, 5/8" G.W.B. 6 5/8"
FS2 2 1/2" 16GA MTL STUD, 5/8" G.W.B. 3 1/8"
FS3 3 5/8" 16GA MTL STUD, 5/8" G.W.B. 4 1/4"
FS6 6" 16GA MTL STUD, 5/8" G.W.B. 6 5/8"
F8 8" MTL STUD, 5/8" G.W.B. 8 5/8"
TYPE P - PARTITION
P3 5/8" G.W.B, 3 5/8" MTL STUD, 5/8" G.W.B. 4 7/8"
P31 5/8" G.W.B, 3 5/8" MTL STUD, 5/8" G.W.B. (1 HR RATED) 4 7/8"
P32 (2) 5/8" G.W.B, 3 5/8" MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 6 1/8"
P6 5/8" G.W.B, 6" MTL STUD, 5/8" G.W.B. 7 1/4"
P61 5/8" G.W.B, 6" MTL STUD, 5/8" G.W.B. (1 HR RATED) 7 1/4"
P8 5/8" G.W.B, 8" MTL STUD, 5/8" G.W.B. 9 1/4"
PS3 5/8" G.W.B, 3 5/8" 16GA MTL STUD, 5/8" G.W.B. 4 7/8"
PS31 5/8" G.W.B, 3 5/8" 16GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 4 7/8"
PS32 (2) 5/8" G.W.B, 3 5/8" 16 GA MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 6 1/8"
PS6 5/8" G.W.B, 6" 16GA MTL STUD, 5/8" G.W.B. 7 1/4"
PS61 5/8" G.W.B, 6" 16GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 7 1/4"
PS62 (2) 5/8" G.W.B, 6" 16GA MTL STUD, (2) 5/8" G.W.B. (2 HR RATED) 8 1/2"
PS8 5/8" G.W.B, 8" 16 GA MTL STUD, 5/8" G.W.B. 9 1/4"
PS81 5/8" G.W.B, 8" 16 GA MTL STUD, 5/8" G.W.B. (1 HR RATED) 9 1/4"
EXISTING WALL
HAT CHANNEL
OR MTL STUD
5/8" TYPE "X" G.W.B.
5/8" TYPE "X" G.W.B.
(2 LAYERS @ 2 HR RATED)
MTL STUD
5/8" TYPE "X" G.W.B.
(2 LAYERS @ 2 HR RATED)
SAFB INSULATION,
FILL CAVITY
SAFB INSULATION,
FILL CAVITY
LEGEND FOR WALL TAGS
PARTITION GROUP DESIGNATOR
HAT CHANNEL, STUD OR CMU SIZEXXX
RATING (IF APPLIES)
UNDERSIDE OF STRUCTURE UNDERSIDE OF STRUCTURE
ACOUSTICAL SEALANT ACOUSTICAL SEALANT @ NON-RATED
WALLS. FIRE SEALANT @ RATED WALLS
DEFLECTION TRACK
DEFLECTION TRACK
ACOUSTICAL SEALANT
WALL BASE AS SCHED.
BASE BASE
METAL CHANNEL
ACOUSTICAL SEALANT @ NON-RATED
WALLS. FIRE SEALANT @ RATED WALLS
WALL BASE AS SCHED.
METAL CHANNEL
TYPE WALL MATERIALS
WALL
WIDTH TYPE WALL MATERIALS
WALL
WIDTH
PLAN
HEAD
PLAN
HEAD
TYPE S - SHAFT
S21 5/8" G.W.B, 2 1/2" C-H STUDS, 1" G.W.B (1 HR RATED) 3 1/8"
S41 5/8" G.W.B, 4" C-H STUDS, 1" G.W.B (1 HR RATED) 4 5/8"
S42 (2) 5/8" G.W.B, 4" C-H STUDS, 1" G.W.B (2 HR RATED) 4 5/8"
5/8" TYPE "X" G.W.B.
C-H MTL STUD
1" TYPE "X" G.W.B.
SAFB INSULATION,
FILL CAVITY
UNDERSIDE OF STRUCTURE
FIRE SEALANT
DEFLECTION TRACK
BASE
FIRE SEALANT
WALL BASE AS SCHED.
METAL CHANNEL
TYPE WALL MATERIALS
PLAN
HEAD
WALL
WIDTHUL
U465 U465
U465
U465 U465
U465 U465
U465
UL
U415 U415 U415
TYPE C - CHASE
(2)5/8" G.W.B, 3 5/8" MTL STUD, 1" AIR, 3 5/8" MTL STUD,
(2)5/8" G.W.B
TYPE WALL MATERIALS
WALL
WIDTH UL
U49310 3/4"C3
5/8" TYPE "X" G.W.B.
(2 LAYERS)
MTL STUD
5/8" TYPE "X" G.W.B.
(2 LAYERS)
SAFB INSULATION,
FILL CAVITY
UNDERSIDE OF STRUCTURE
ACOUSTICAL SEALANT
DEFLECTION TRACK
BASE
ACOUSTICAL SEALANT
WALL BASE AS SCHED.
METAL CHANNEL
PLAN
HEAD
SCOPE OF WORK LEGEND
SHADED AREA NOT IN SCOPE OF WORK
NOTES:
WALL HEIGHT
SHADED WALLS INDICATE WALLS
THAT EXTEND TO DECK
WALLS TO RECEIVE GYPSUM BOARD PRODUCT ON BOTH FACES
OF METAL STUD AND WALLS THAT REQUIRE ACOUSTICAL SOUND
BATT INSULATION SHALL BE CONSTRUCTED TO MEET A MINIMUM
45 STC UNLESS OTHERWISE NOTED.
ALL STUD FRAMING TO BE 16" O.C., TYP.
LIGHT GAUGE METAL STUDS, 20GA/19MIL TYP. (16GA AT TOILET
ROOM PLUMBING WALLS & SHOWER SEAT WALLS) (REF. SPECS.)
PROVIDE COATED GLASS MAT TILE BACKER BOARD AT ALL
SHOWER & WET AREAS AND AS BACKER FOR CERAMIC WALL
TILE. TOILET & SINK AREAS TO RECEIVE MOISTURE-RESISTANT
GYP BOARD. PROVIDE 20GA. STUDS AS REQUIRED IN TCNA AND
GA-216.
PROVIDE ACOUSTICAL SEALANT AT TOP & BOTTOM AND ALL
PENETRATIONS OF WALLS WITH SOUND BATT.
PROVIDE SEALANT AT TOP & BOTTOM AND ALL PENETRATIONS OF
SMOKE PARTITION WALLS AS REQUIRED BY CODE - REF. SPECS.
PROVIDE ALL NEW WALLS THAT GO TO STRUCTURE w/ 1 1/2" MTL.
DEFLECTION TRACK - REF STRUCT.
BRACE ALL STUD WALLS TO STRUCTURE ABOVE @ 4'-0" O.C. OR
EXTEND ALL STUDS TO DECK ABOVE, TYP.
INSTALL FIRE RATED SEAL/CLOSURE @ ALL OPENINGS, GAPS
AND TOP & BOTTOM OF FRAMING AS REQUIRED BY CODE - REF.
SPEC.
INSTALL 5/8" TYPE X GYP BD ON ONE SIDE OF FURRING, TYP.
INSTALL 5/8" TYPE X GYP BD ON BOTH SIDES OF STUD FRAMING,
TYP., UNLESS NOTED OTHERWISE.
EXTEND GYP BD TO 6" ABOVE CEILING UNLESS REQUIRED
OTHERWISE.
PROVIDE 20GA DOUBLE STUDS FULL HEIGHT AT ALL INTERIOR
DOOR JAMBS.
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE105
FLOOR PLAN - DIMENSIONS - 4TH
FLOOR AREA B
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
KEYNOTES
KEY VALUE KEYNOTE TEXT
1.01 GC TO VERIFY THE RATING OF EXISTING WALL AND UTILIZE ANY MEASURES
NECESSARY TO MAKE IT 1-HR RATED.
8.04A 24"X24" RATED ACCESS DOOR, REF. LIFE SAFETY PLANS FOR REQUIRED RATING,
"BEST CORE" LOCK BY DOOR HARDWARE SUPPLIER.
8.33 ROLL UP SECURITY GRILLE, REF. SPECS.
10.40 FULLY RECESSED F.E.C.
22.34 FLOOR DRAIN, REF. PLUMBING.
22.47 BI-LEVEL ADA DRINKING FOUNTAIN W/ BOTTLE FILLING STATION, REF. PLUMBING.
3/16" = 1'-0" D2
4TH FLOOR - DIMENSIONS - AREA B
0' 2'-8" 5'-4" 10'-8"
N
CEILING ACCESS PANEL
WALL MOUNT FIXTURE
CEILING HEIGHT
SYMBOL LEGEND
RECESSED CAN FIXTURE
EXHAUST GRILLE
NOTE:
A. REFERENCE MECHANICAL & ELECTRICAL
DRAWINGS FOR SYMBOLS NOT SHOWN HERE.
B. ALL FIXTURES TO BE LED.
RETURN GRILLE
RETURN GRILLE
2X2 LED FIXTURE - NORMAL
EXHAUST GRILLE
SURFACE MOUNT FIXTURE
SUPPLY DIFFUSER
SUPPLY DIFFUSER
WALL WASH SLOT
2X2 LED FIXTURE - LIFE SAFETY
EXIT SIGN
SECURITY CAMERA
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
B. P- # ARE PAINT COLORS; REF. TO COLOR SCHEDULE KEY ON SHEET AI101 FOR MORE
INFORMATION.
GENERAL RCP NOTES
FOURTH FLOOR KEY PLAN
AREA A
N
B
A
421A
426A
402403
C41
404 401
401A
405A
C45
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0" 9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
8' - 0"
8' - 0"
C43
9' - 0"
C46
C47
9' - 0"
A6
AE501
SIM
A6
AE501
SIM
________A6
AE501
SIM
9' - 0"
B5
AE501
P-5
P-4
8' - 0"
8' - 0" P-5
10.21
10.21
10.21 8' - 6"
/4
8' - 10"
7 1/4"
8' - 6"
8' - 6"
9 1/4"
/4
8' - 10"
4 7/8"
8' - 10"
/8
8' - 10"
9 1/4"
10.21
10.21
B5
AE501
B5
AE501
B5
AE501
B5
AE501
B5
AE501
9' - 0"
C5
AE501
/4
/8
/4
/4
C5
AE501
SIM
________9' - 0"
9' - 0" 9' - 0"
8.07
D5
AE501
P-4
11.50A11.50A11.50A 11.50A
P-1
P-1
P-1
P-1
P-1
P-1
P-1
B3
AE501
11.50A11.50A
11.50A11.50A
SCOPE OF WORK LEGEND
SHADED AREA NOT IN SCOPE OF WORK
GYP BOARD
CEILING/SOFFIT
RCP LEGEND
2' X 2' ACOUSTICAL
CEILING TILE
2' X 2' PRINTED
ACOUSTICAL
CEILING TILE
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE120
REFLECTED CEILING PLAN - 4TH
FLOOR - AREA A
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
KEYNOTES
KEY VALUE KEYNOTE TEXT
8.07 OPERABLE PARTITIONS W/ BUILT-IN DOOR, REF. SPECS.
10.21 CUBICLE CURTAIN TRACK, REF. SPEC.
11.50A CEILING MOUNTED PATIENT LIFT SYSTEM - 770 LBS CAPACITY. PARALLEL RAILS
RECESSED INTO CEILING. VA SUPPLIED AND INSTALLED UNDER A SEPARATE
CONTRACT. THIS CONTRACTOR TO COORDINATE LIFT LOCATION W/ MEP ELEMENTS.
0' 2'-8" 5'-4" 10'-8"
N
3/16" = 1'-0" D2
REFLECTED CEILING - 4TH FLOOR - AREA A
CEILING ACCESS PANEL
WALL MOUNT FIXTURE
CEILING HEIGHT
SYMBOL LEGEND
RECESSED CAN FIXTURE
EXHAUST GRILLE
NOTE:
A. REFERENCE MECHANICAL & ELECTRICAL
DRAWINGS FOR SYMBOLS NOT SHOWN HERE.
B. ALL FIXTURES TO BE LED.
RETURN GRILLE
RETURN GRILLE
2X2 LED FIXTURE - NORMAL
EXHAUST GRILLE
SURFACE MOUNT FIXTURE
SUPPLY DIFFUSER
SUPPLY DIFFUSER
WALL WASH SLOT
2X2 LED FIXTURE - LIFE SAFETY
EXIT SIGN
SECURITY CAMERA
A. REF. SPECIFICATION SECTION 13 05 41 "SEISMIC RESTRAINT REQUIREMENTS FOR NON-
STRUCTURAL COMPONENTS" FOR BRACING REQUIREMENTS FOR CEILINGS AND LIGHTING
FIXTURES
B. P- # ARE PAINT COLORS; REF. TO COLOR SCHEDULE KEY ON SHEET AI101 FOR MORE
INFORMATION.
GENERAL RCP NOTES
FOURTH FLOOR KEY PLAN
AREA B
N
B
A
440A
450A
C43
C44
401 401A
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0"
9' - 0" 9' - 0"
8' - 0"
9' - 0"
9' - 0"
11.55A
11.55A
11.55A
8' - 10"
C42
C41
C45
405A
9' - 0"
9' - 0"
9' - 0"
8' - 0"
A6
AE501
A6
AE501
SIM
A6
AE501
SIM
A5
AE501
SIM
9' - 0" 9' - 0"
8' - 0" 9' - 0"
B5
AE501
10.21
9 1/4"
/4
/4
8' - 6"
8' - 0"
8' - 10"
8' - 10"
10.21
10.21
10.21
11.50A11.50A
10.21
10.2110.21 10.2110.21
10.21
10.21
10.21
10.21
10.21
B5
AE501
B5
AE501
A4
AE501
A4
AE501
C5
AE501
SIM
9' - 0"
9' - 0"
404A
7'
0"
1' - 5"
P-4
P-4
A4
AE501
A5
AE501
11.55B
11.55B
11.55B
10' - 0"
10' - 0"
10' - 0" B4
AE501
SIM
P-1
P-1
P-1
P-1
P-1
P-1
/8
4 7/8"
4 7/8"
B5
AE501
B5
AE501
11.50A11.50A11.50A11.50A
11.50A11.50A
11.50A11.50A
11.50A11.50A
11.50A11.50A
11.50A11.50A
11.50A11.50A
11.50A
11.50A11.50A
SCOPE OF WORK LEGEND
SHADED AREA NOT IN SCOPE OF WORK
GYP BOARD
CEILING/SOFFIT
RCP LEGEND
2' X 2' ACOUSTICAL
CEILING TILE
2' X 2' PRINTED
ACOUSTICAL
CEILING TILE
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE121
REFLECTED CEILING PLAN - 4TH
FLOOR - AREA B
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
KEYNOTES
KEY VALUE KEYNOTE TEXT
10.21 CUBICLE CURTAIN TRACK, REF. SPEC.
11.50A CEILING MOUNTED PATIENT LIFT SYSTEM - 770 LBS CAPACITY. PARALLEL RAILS
RECESSED INTO CEILING. VA SUPPLIED AND INSTALLED UNDER A SEPARATE
CONTRACT. THIS CONTRACTOR TO COORDINATE LIFT LOCATION W/ MEP ELEMENTS.
11.55A CEILING MOUNTED GAIT TRACK - I BEAM
11.55B CEILING MOUNTED GAIT TRACK - POWER RAIL
0' 2'-8" 5'-4" 10'-8"
N
3/16" = 1'-0" D2
REFLECTED CEILING - 4TH FLOOR - AREA B
C
A. ANY DISCREPANCIES OR CONFLICTS FOUND IN THE VARIOUS PARTS OF THE
CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT
AND THE OWNER BEFORE PROCEEDING WITH THE WORK.
B. FILL SURFACE OF CONCRETE WALLS WITH AN APPROPRIATE FILLER AND MAKE SMOOTH.
SEAL OR PRIME ABSORBENT SURFACES WITH A SUITABLE DILUTED ACRYLIC PRIMER.
ALLOW PAINT/PRIMER TO DRY IN ACCORDANCE WITH THE MANUFACTURERS APPLICATION
INSTRUCTIONS. UNFILLED GROUT LINES MAY TELEGRAPH THROUGH THE SHEET; GC TO
COORDINATE WITH MANUFACTURER PROPER THICKNESS AND INSTALLATION METHOD.
C. GYPSUM WALLS NEED TO BE PAINTED PRIOR TO INSTALLATION OF PLYWOOD.
D. ITEMS/EQUIPMENT IN LIGHT GRAY ( ) ARE FOR REFERENCE ONLY.
E. ALL DIMENSIONS ARE TO FACE OF STUDS U.N.O.
F. ALL SPOT ELEVATIONS ARE TO FINISH FLOOR U.N.O
GENERAL PLAN NOTES
J
AI401
D2
D3 D1
STAFF TLT.
1' - 0 1/2" 6' - 4 7/8"
F2
F2
P3
P3
PS6
P3
ALIGN
ALIGN
22.34
22.10A
22.01
6.2
K Jb
AI401C2
AI401 A4
A5
B2
B1
B5
B4
C1
MEN'S TLT
WOMEN'S
TLT
P3
P3
FS3
F2 F2
F3
FS3
FS6
FS3
P3 P3
P6
/8
6' - 4 7/8" 5' - 11 3/8"
3 1/2"
5' - 7 3/8" 6' - 7 1/4"
P3P3
FS6
P3 4
/8
ALIGN
22.34
22.34
10.40
D6
AE501
1' - 7 1/8" 4' - 3 13/16" 4' - 3 13/16" 1' - 10 3/4"1' - 6 1/2" 1' - 5 3/4" 1' - 5 3/4" 1' - 5 3/4" 4' - 0 3/8" 1' - 7 1/8"
/2
/2
EQ EQ
1' - 5 1/2"
22.1110.02
22.11
12.22 12.22
22.10A 22.10A 22.10A
10.01A10.01A 10.01A10.01A10.01A
1.30 1.30
AI403B4
HSKPG.
/8
7' - 4 7/8"
P31
P3
P3
P31
3' - 11 1/4" 3' - 5 5/8"
ALIGN
22.31
22.34
G
AI402C5
C3
C4
PT TLT.
P3
P3
PS6
/8
22.34
22.10A
6' - 3 7/8"
22.14
Ma
AI403
A3
A4 A5
STAFF TLT.
13' - 3 1/4"
P3
FS6
P6
PS3
22.34
10.40
D6
AE501
22.10A
22.01
9 1/4"
F3
F3
F3
F.1
AI402
D5
D4
D6 D3
OT TLT.
440A
1' - 1 3/4" 5' - 8" 5' - 4 3/4"
P3
P3 P3
PS3
PS3
PS3P3
P3
P3
P3
/8
/8
/4
440A
6' - 9 3/4" 5' - 4 3/4"
FS2
F3
FS6
F2
22.10B
22.34
22.13B
7' - 1 1/4" 6' - 3 3/4"
F3
1.30
1/2"
7/8"
7/8"
7/8"
1/2"
7/8"
7/8"
7/8"
1/2"
7/8"
STAFF TLT.
/4
M
IN
/8
MIN. 1/8" / 1'-0"
M
IN
/8
MIN. 1/8" / 1'-0"
[No Slope]
1/2"
1"
1" 1/2"
1/2"1"
1"
HSKPG.
1/4" / 1'-0"
M
IN
/8
M
IN
/8
1/4" / 1'-0" 1/4" / 1'-0"
1/2"
1"
1"
1"
1"
1"
1"
1/2"
1/2"
STAFF TLT.
[No Slope]
MIN. 1/8" / 1'-0"
M
IN
/8
M
IN
/8
MIN. 1/8" / 1'-0"
1/4" / 1'-0"
PT TLT.
1/2"
7/8" 1/2"
1/2"
7/8"7/8"
7/8"
7/8"
7/8"
M
IN
/8
M
IN
/8
MIN. 1/8" / 1'-0"
MIN. 1/8" / 1'-0"
[No Slope]
1/4" / 1'-0"
WOMEN'S
TLT
MEN'S TLT
1/2"
1 1/4" 1 1/4"
1 1/8"
1/2" 1 1/8"
1 1/8"
1 1/8"
1 1/8"
1/2"
1 1/4" 1 1/4"
1/2"
1 1/4"
1 1/4"
1 1/4"
1 1/4"
1 1/8"
1/2" 1/2" 1 1/8" 1 1/8"
1 1/8"
1 21/128"
M
IN
/8
M
IN
/4
MIN. 1/8" / 1'-0"
M
IN
/8
MIN. 1/8" / 1'-0"
[No Slope][No Slope]
M
IN
/8
MIN. 1/8" / 1'-0"
MIN. 1/8" / 1'-0"
M
IN
/8
M
IN
/4
1" 1"
1"
1/2"
1/2"
1/2"
1" 1"
1"1"1"
1"
1"
1"
1"
OT TLT.
440A
1/4" / 1'-0" MIN. 1/8" / 1'-0"
M
IN
/8
MIN. 1/8" / 1'-0"
M
IN
/8
[No Slope]
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE401
ENLARGED PLANS - SLOPED FLOORS
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
KEYNOTES
KEY VALUE KEYNOTE TEXT
1.30 PARTIAL HEIGHT WALL, H = 7'-2"
10.01A FLOOR MOUNTED TOILET PARTITION, REF. SPECS.
10.02 URINAL SCREEN - WALL HUNG, REF. SPEC.
10.40 FULLY RECESSED F.E.C.
12.22 SOLID SURFACE COUNTERTOP WITH INTEGRAL LAVATORY.
22.01 SINK - REF. PLUMBING.
22.10A ADA TOILET - REF. PLUMBING.
22.10B LOW HEIGHT FLOOR MOUNTED TOILET, REF. PLUMBING.
22.11 URINAL - REF. PLUMBING.
22.13B RESIDENTIAL STYLE TUB/SHOWR UNIT, REF. PLUMBING.
22.14 ADA-COMPLIANT BARIATRIC LAVATORY, REF. PLUMBING.
22.31 MOP SINK - REF. PLUMBING.
22.34 FLOOR DRAIN, REF. PLUMBING.
1/2" = 1'-0" A1
ENLARGED PLAN - 414 STAFF TLT.
1/2" = 1'-0" D1
ENLARGED PLAN - PUBLIC TOILETS
1/2" = 1'-0" A2
ENLARGED PLAN - HSKPG.
1/2" = 1'-0" C6
ENLARGED PLAN - PT TLT.
1/2" = 1'-0" A3
ENLARGED PLAN - 462 STAFF TLT.
1/2" = 1'-0" B3
ENLARGED PLAN - OT TLT.
1/2" = 1'-0" B1
SLOPED FLOOR - 414 STAFF TLT.
1/2" = 1'-0" B2
SLOPED FLOOR - HSKPG.
1/2" = 1'-0" A5
SLOPED FLOOR - 462 STAFF TLT.
1/2" = 1'-0" D6
SLOPED FLOOR - PT TLT.
1/2" = 1'-0"
D4
SLOPED FLOOR - PUBLIC TOILETS
1/2" = 1'-0" B5
SLOPED FLOOR - OT TLT.
VARIES REF.
CEILING PLAN
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
VARIES REF.
CEILING PLAN
VARIES REF.
CEILING PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
5/8" GYP. BD. BULKHEAD ON
MTL. STUD FRAMING @ 16"
O.C. REF. PLANS FOR SIZE
M
IN
VARIES REF.
CEILING PLAN
GYP. BD. ON MTL.
STUDS - REF. PART.
SCHED.
GYP. BD. SOFFIT ON
3 5/8" MTL. STUD
FRAMING @ 16" O.C.
SUSPENDED ACOUST. CLG.
SYSTEM - REF. PLANS
WHEN SOFFIT OCCURS AT
MILLWORK VERIFY DEPTH WITH
MILLWORK DETAIL
REF. PLAN
3 5/8" MTL. STUD FRAMING
@ 16" O.C. MIN. UNLESS
NOTED OTHERWISE
VARIES REF.
CEILING PLAN
GYP. BD. TO CONT. UP
TO DECK @ RATED &
SOUND PARTITIONS -
REF. PART. SCHED.
3 5/8" MTL. STUD CROSS
BRACING @ 4'-0" O.C.
ACOUSTICAL CEILING
TILE, REF. SPECS.
EXISTING WINDOW
EXISTING WALL ASSEMBLY
WINDOW ROLLER
SHADE, REF. SPECS.
WINDOW SHADE
POCKET, INTEGRATED
W/ ACT SYSTEM, REF.
SPECS.
2x NAILER / BLOCKING 5"
BATT INSULATION
REF. PLAN 5" REF. PLAN
5/8" GYPSUM BOARD,
TYPE "X"
ROLL UP SECURITY
GRILLE, REF. SPECS.
3 5/8" STL STUD
5/8" GYPSUM BOARD,
TYPE "X"
/D2 AE120
M
IN
ACOUSTICAL CEILING
TILE, REF. SPECS.
M
IN
3 5/8" MTL. STUD
CROSS BRACING @
4'-0" O.C.
3 5/8" MTL. STUD
CROSS BRACING @
4'-0" O.C.
/D2 AE120
5"
ACOUSTICAL CEILING
TILE, REF. SPECS.
5/8" GYPSUM BOARD,
TYPE "X"
SOUND ATTENUATION
BATT INSULATION
SOUND ATTENUATION
BATT INSULATION
SUPPORT TO STRUCTURE,
REF. MANUF REQ
M
IN
W8X40 PARTITION SUPPORT
BEAM, ATTACHED TO FLOOR
SUPPORTED HSS POSTS ON
EACH END
HSS 5X3X1/4" BEYOND
OPERABLE PARTITIONS
W/ BUILT-IN DOOR, REF.
SPECS.
54" MAX.
TOP OF CABINET
OPENING, U.N.O.
TAPE & SEAL ALL JOINTS TO
MAINTAIN FIRE & SMOKE
RATINGS WHERE APPLICABLE.
PLAN VIEW
SECTION VIEW
6" STL STUD
5/8" GYPSUM BOARD,
TYPE "X"
FULLY RECESSED F.E.C.
5/8" GYPSUM BOARD,
TYPE "X"
FULLY RECESSED F.E.C.
5/8" GYPSUM BOARD,
TYPE "X"
5/8" GYPSUM BOARD,
TYPE "X"
SOLID SURFACE WDW
SILL, REF. FINISH
SCHEDULE
EXISTING WINDOW
EXISTING WALL ASSEMBLY
5/8" GYPSUM BOARD,
TYPE "X"
2 1/2" STL STUD
2x NAILER / BLOCKING
BATT INSULATION
1/4"
EXISTING WINDOW
EXISTING WALL ASSEMBLY
WINDOW ROLLER
SHADE, REF. SPECS.
WINDOW SHADE
POCKET, INTEGRATED
W/ ACT SYSTEM, REF.
SPECS.
2x NAILER / BLOCKING 5"
5/8" GYPSUM BOARD,
TYPE "X"
5/8" GYPSUM BOARD,
TYPE "X"
BATT INSULATION
ACOUSTICAL CEILING
TILE, REF. SPECS.
5TH LEVEL
51' - 9 1/4"
FIRE RATED SEALANT
5/8" GYPSUM BOARD,
TYPE "C"
HORIZONTAL 2HR ASSEMBLY
UL DESIGN: G586
4" J TRACK SHAFT WALL
4" C-H MTL STUD
1" SHAFT LINER BOARD
5/8" GYPSUM BOARD,
TYPE "C"
5/8" GYPSUM BOARD,
TYPE "C"
EXISTING SHAFT WALL
ASSEMBLY
EXISTING CONC. FLOOR
ASSEMBLY
OPERABLE PARTITIONS
W/ BUILT-IN DOOR, REF.
SPECS.
/D2 AE104
5/8" GYPSUM BOARD,
TYPE "X"
3 5/8" STL STUD
5/8" GYPSUM BOARD,
TYPE "X"
SOUND ATTENUATION
BATT INSULATION
12"X4 1/4"X 1/4" STL PLATE
(4) 1/2" EXP. BOLTS FOR
CONC.
HSS 5X3X1/4" WELDED TO
BOT PLATE W/ 3/16" WELD
RIGID WALL COVERING,
REF. INTERIOR & SPECS.
PREFIN METAL
FLASHING
BACKER ROD & SLNT
4X4 BRICK LINTEL,
PAINTED
AIR & MOISTURE
BARRIER
MECH. DUCT
THRU-WALL FLASHING
W/ DRIP
/D2 AE120
2x NAILER / BLOCKING
2 1/2" STL STUD
BACKER ROD & SLNT
BATT INSULATION
BACKER ROD & SLNT
THRU-WALL FLASHING
W/ DRIP
AIR & MOISTURE
BARRIER
BACKER ROD & SLNT
4" MIN
M
IN BACKER ROD & SLNT
EXIST. WALL ASSEMBLY
M A
X
/2
M A
X
/2
AIR & MOISTURE
BARRIER
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE501
DETAILS
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
1 1/2" = 1'-0" B5
DETAIL @ AT/GYP/AT BULKHEAD
1 1/2" = 1'-0" A4
DETAIL @ GYP SOFFIT & AT
1 1/2" = 1'-0"
A6
SECTION DETAIL - WINDOW SHADE, TYP.
1 1/2" = 1'-0" C5
SECTION DETAIL - MOTORIZED SECURITY ROLL DOWN GRILL AT MSA
1 1/2" = 1'-0" D5
SECTION DETAIL - OPERABLE PARTITION
HEAD
1 1/2" = 1'-0" D6
FULLY RECESSED FIRE EXT. CABINET
1 1/2" = 1'-0" B6
SECTION DETAIL - WINDOW SILL, TYP.
1 1/2" = 1'-0" A5
SECTION DETAIL - WINDOW SHADE @
GAIT TRACK, TYP.
1 1/2" = 1'-0" B4
SECTION DETAIL - SHAFT INFILL @
CEILING (UL G586)
1 1/2" = 1'-0" D4
PLAN DETAIL - OPERABLE PARTITION
JAMB
1 1/2" = 1'-0" B3
SECTION DETAIL - EXT. WALL DUCT
PENETRATION
A C DB
R E
F S
C H
E D
REF. SCHED.
R E
F S
C H
E D
REF. SCHED.
R E
F S
C H
E D
REF. SCHED.
REF. SCHED.
9"
4"
100 SQ. IN. @
FIRE RATED
OPENINGS
GLASS SHALL
BE TYPE MG #1
OR FR #1 AT
RATED DOORS -
REF. SCHED.
STAINLESS STEEL
PROTECTION
PLATE
C1
R E
F S
C H
E D
REF. SCHED.
T
9" 9"
GLASS SHALL
BE TYPE MG #1
OR FR #1 AT
RATED DOORS -
REF. SCHED.
E
ROLLING SECURITY GRILLE
SEE SCHED.
S E
E S
C H
E D
NOT USED
- ALL DOOR FRAME THROAT SIZES TO BE VERIFIED BY CONTRACTOR.
- ALL DOORS TO HAVE 4 HINGES.
- ALL DOOR FRAMES TO HAVE REINFORCEMENT FOR CLOSER.
GENERAL NOTES:
1 2
R E
F S
C H
E D
2"
SCHED.
REF. 2"
SINGLE DOOR
R E
F S
C H
E D
2"
SCHED.
REF.
SCHED.
REF. 2"
DBL. DOOR
/2
R E
F S
C H
E D
2"
SCHED.
REF. 2"
SINGLE DOOR W/
LIFT TRACK NOTCH
EQ. 3" EQ.
NOTCH FOR PATIENT LIFT
TRACK. VERIFY SIZE AND
LOCATION W/ LIFT SYSTEM
VENDOR PRIOR TO
FABRICATION
11"
LIFT TRACK
CURTAINWALL / STOREFRONT
SYSTEM
NOT USED
R E
F S
C H
E D
2"
SCHED.
REF. 2"
SINGLE DOOR
MASONRY
R E
F S
C H
E D
2"
SCHED.
REF.
SCHED.
REF. 2"
DBL. UNEVEN
DOOR
R E
F S
C H
E D
2"
REF. HDWR .MANUF.
SCHED.
REF. 2"
SINGLE DOOR
ANTI-BARRICADE HDWR
FULL-LENGTH
DOUBLE SWING
HINGE
EMERGENCY RELEASE
STOP
NOTES:
FT FULLY TEMPERED
IG INSULATED GALSS
SP SPANDREL PANEL
S
IL
L
W1 W2 W3
3' - 0 3/8" 2' - 11 3/8" 3' - 0 3/8"
9' - 0"
S
IL
L
3' - 11 1/4" 3' - 10 1/4" 3' - 10 1/4" 3' - 10 1/4" 3' - 11 1/4"
19' - 5"
3' - 11 5/8" 3' - 10 5/8" 3' - 11 5/8"
11' - 10"
S
IL
L
FT FT FT FT FT FT FT FT FT FT FT
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AE601
SCHEDULES
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
IEPJHK
DOOR SCHEDULE
DOOR NO. SIZE
HDWR
SET FIRE RATING
DOOR FRAME
REMARKSTYPE MATERIAL
PANEL
FINISH GLASS TYPE MATERIAL
GLAS
S
401 2'-6" x 7'-0" x 1 3/4" PR 4.0 20 MINS. B WD WDR-1 1/4" FIRE RATED 2 HM - PASSAGE FUNC., AUTO OPERATOR BOTH SIDES
401B 2'-8" x 7'-0" x 1 3/4" 20.0 45 MINS. A WD WDR-1 - 5 HM - CLASSROOM FUNC., CLOSER
402 3'-6" x 7'-0" x 1 3/4" 31.0 NR A WD WDR-1 - 1 HM - PUSH/PULL, AUTO OPERATOR BOTH SIDES
403 3'-6" x 7'-0" x 1 3/4" 31.0 NR A WD WDR-1 - 1 HM - PUSH/PULL, AUTO OPERATOR BOTH SIDES
404A 3'-0" x 7'-0" x 1 3/4". 9.0 NR A WD WDR-1 - 5 HM - STOREROOM FUNC., CLOSER
404B 3'-0" x 7'-0" x 1 3/4" PR 5.0 45 MINS. B WD WDR-1 1/4" FIRE RATED 2 HM - CARD READER OUTSIDE, AUTO OPERATOR INSIDE, CLOSER, ARMOR PLATE BOTH SIDES
404C 3'-6" x 7'-0" x 1 3/4". 10.0 45 MINS. B WD WDR-1 1/4" FIRE RATED 5 HM - STOREROOM FUNC., CLOSER, ARMOR PLATE BOTH SIDES
405A 3'-0" x 7'-0" x 1 3/4" 13.0 45 MINS. B WD WDR-1 1/4" FIRE RATED 1 HM - OFFICE FUNC., LOCK FROM 405 SIDE
405B 3'-6" x 7'-0" x 1 3/4" 6.0 45 MINS. B WD WDR-1 1/4" FIRE RATED 1 HM - CARD READER OUTSIDE, AUTO OPERATOR INSIDE, CLOSER, ARMOR PLATE
405C 3'-6" x 7'-0" x 1 3/4" PR 2.0 45 MINS. B WD WDR-1 1/4" FIRE RATED 2 HM - CARD READER OUTSIDE, AUTO OPERATOR INSIDE, CLOSER, ARMOR PLATE PUSH SIDE EACH DOOR
405D 9'-6" x 9'-0" 32.0 NR E ALUM - - - ALUM - MOTORIZED
411 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
412 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
413 3'-6" x 7'-0" x 1 3/4" 15.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
414 3'-6" x 7'-0" x 1 3/4" 22.0 NR A WD WDR-1 - 7 HM - FULL-LENGTH DOUBLE SWING HINGE, KEYED JAMB, PRIVACY INDICATOR
415 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
416 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
417 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
418 3'-6" x 7'-0" x 1 3/4" PR 8.0 NR A WD WDR-1 - 1 HM - STOREROOM FUNC., CLOSER W/ HOLD OPEN, 110-DEGREE SWING
419 4'-0" x 7'-0" x 1 3/4" 17.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
420 3'-6" x 7'-0" x 1 3/4" 19.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC., CLOSER W/ HOLD OPEN, SEALS, COORDINATION SENSOR W/ DOOR 424
421 3'-6" x 7'-0" x 1 3/4" 25.0 NR B WD WDR-1 1/4" SAFETY 1 HM - PASSAGE FUNC., CLOSER, SEALS, FLOOR SWEEP
421A 3'-6" x 7'-0" x 1 3/4" 26.0 NR A WD WDR-1 - 1 HM - PASSAGE FUNC., CLOSER W/ HOLD OPEN, SEALS, STC RATED
422 3'-6" x 7'-0" x 1 3/4" 27.0 NR B WD WDR-1 1/4" SAFETY 1 HM - PASSAGE FUNC., CLOSER, SEALS
423 3'-6" x 7'-0" x 1 3/4" 27.0 NR B WD WDR-1 1/4" SAFETY 1 HM - PASSAGE FUNC., CLOSER, SEALS
424 3'-6" x 7'-0" x 1 3/4" 24.0 NR B WD WDR-1 1/4" SAFETY 1 HM - PASSAGE FUNC., CLOSER W/ HOLD OPEN, SEALS, COORDINATION SENSOR W/ DOOR 420
425 3'-6" x 7'-0" x 1 3/4" 16.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC.
426 3'-6" x 7'-0" x 1 3/4" 16.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC.
426A 3'-6" x 7'-0" x 1 3/4" 28.0 NR A WD WDR-1 - 1 HM - PASSAGE FUNC., CLOSER, ARMOR PLATE, 180-DEGREE SWING
430 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
431 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
432 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
433 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
434 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
435 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
436 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
437 3'-6" x 7'-0" x 1 3/4" 22.1 NR A WD WDR-1 - 7 HM - FULL-LENGTH DOUBLE SWING HINGE, KEYED JAMB, PRIVACY INDICATOR
438 3'-6" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
439A 2'-6" x 7'-0" x 1 3/4" 29.0 90 MINS. A WD WDR-1 - 1 HM - PASSAGE FUNC., CLOSER
439B 2'-6" x 7'-0" x 1 3/4" 9.0 NR A WD WDR-1 - 1 HM - STOREROOM FUNC., CLOSER
439C 2'-6" x 7'-0" x 1 3/4" 9.0 NR A WD WDR-1 - 1 HM - STOREROOM FUNC., CLOSER
440 4' 0" x 7' 0" x 1 3/4" + 1' 6" x 7' 0" x 1 3/4" 12.0 NR D WD WDR-1 - 3 HM - OFFICE FUNC., MANUAL LATCH TOP BOLT
440A 4'-0" x 8'-5" x 1 3/4" 21.0 NR A WD WDR-1 - 4 HM - PRIVACY INDICATOR
450 3'-0" x 7'-0" x 1 3/4" PR 1.0 20 MINS. B WD WDR-1 1/4" FIRE RATED 2 HM - CARD READER OUTSIDE, AUTO OPERATOR BOTH SIDES, CLOSER
450A 3'-6" x 7'-0" x 1 3/4" 30.0 NR A WD WDR-1 - 1 HM - PASSAGE FUNC., CLOSER, ARMOR PLATE
451 4'-0" x 7'-0" x 1 3/4" 14.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
452 3'-6" x 7'-0" x 1 3/4" 18.0 45 MINS. A WD WDR-1 - 1 HM - OFFICE FUNC., 10" KICK PLATE
453 3'-0" x 7'-0" x 1 3/4" 3.0 NR A WD WDR-1 - 1 HM - STOREROOM FUNC., CLOSER, PANIC HDWR
460A 3'-6" x 7'-0" x 1 3/4" 15.0 NR C1 WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
460B 3'-6" x 7'-0" x 1 3/4" 15.0 NR C1 WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
461 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
462 3'-6" x 7'-0" x 1 3/4" 22.0 NR A WD WDR-1 - 7 HM - FULL-LENGTH DOUBLE SWING HINGE, KEYED JAMB, PRIVACY INDICATOR
463 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
464 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
465 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
466 3'-6" x 7'-0" x 1 3/4" 16.0 NR B WD WDR-1 1/4" SAFETY 1 HM - OFFICE FUNC.
467 3'-6" x 7'-0" x 1 3/4" 16.0 NR A WD WDR-1 - 1 HM - OFFICE FUNC.
468 3'-6" x 7'-0" x 1 3/4" 23.0 NR B WD WDR-1 1/4" SAFETY 1 HM - PASSAGE FUNC.
469 3'-6" x 7'-0" x 1 3/4" 11.0 NR A WD WDR-1 - 1 HM - STOREROOM FUNC., CLOSER, ARMOR PLATE
470 28'-2" x 9'-0" 32.0 NR E ALUM - - - ALUM - MOTORIZED
C42 4'-0" x 7'-0" x 1 3/4" 7.0 20 MINS. B WD WDR-1 1/4" FIRE RATED 1 HM - CARD READER OUTSIDE, CLOSER
C44 4'-0" x 7'-0" x 1 3/4" 7.0 20 MINS. B WD WDR-1 1/4" FIRE RATED 1 HM - CARD READER OUTSIDE, CLOSER
1/4" = 1'-0"
DOOR TYPE ELEVATIONS
1/4" = 1'-0"
DOOR FRAME ELEVATIONS
1/4" = 1'-0"
WINDOW TYPES
GENERAL NOTES
FINISH SCHEDULE NOTES
A. ALL FLOORING TRANSITIONS OCCUR AT THE CENTERLINE OF THE DOOR. FLOOR COVERINGS SHALL BE BUILT UP OR CUT DOWN TO EXISTING SLAB TO HAVE MINIMAL HEIGHT DIFFERENCES AT
TRANSITIONS.
B. REFER TO FLOOR FINISH PLAN(S) TO DEPICT FINISH MATERIALS, FLOOR PATTERNS, AND ACCENT WALL PAINT IN AREAS AND/OR ROOMS OF SPECIAL SIGNIFICANCE. REFER TO FINISH
SCHEDULE FOR INDIVIDUAL ROOM MATERIAL SELECTIONS.
C. REFERENCE SPECIFICATIONS, ELEVATIONS, AND DETAIL DRAWINGS FOR SPECIAL MATERIALS.
D. ALL WINDOW SILLS TO BE SOLID SURFACE (SS-2).
E. DOOR FRAMES TO BE PAINTED (P-6) U.N.O.
F. WOOD GRAIN LAMINATES TO BE INSTALLED WITH WOOD GRAIN RUNNING VERTICALLY U.N.O.
G. PAINT ALL WORKSURFACE BRACKETS COLOR OF ADJACENT SURFACE.
H. WHERE WALL PROTECTION TRIM IS NOT SPECIFIED, CAULK ALL EXPOSED EDGES OR SEAMS OF WALL PROTECTION (WP) WITH CLEAR CAULKING.
I. REFER TO WALL PROTECTION PLAN FOR ADDITIONAL WALL PROTECTION LOCATION AND HEIGHTS WHICH MAY NOT BE INDICATED ON THIS SCHEDULE.
J. REFER TO ELEVATIONS FOR TILE PATTERNS.
K. SOFFIT PAINT COLOR WILL BE APPLIED TO BOTH THE VERTICAL AND HORIZONTAL SURFACES. ALL SOFFITS TO BE PAINTED THE COLOR OF ADJACENT WALL U.N.O.; SPECIALTY SOFFITS WILL BE
INDICATED IN THE REFLECTED CEILING PLAN AND FINISH SCHEDULE.
L. REFERENCE REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND SOFFIT ACCENT PAINT LOCATIONS.
M. ALL GYP BD CEILINGS TO BE PAINTED CEILING (P-2 OR SC-2), U.N.O.
N. INSTALL GROUT COLOR MATCHING FLEXIBLE SEALANT AT ALL TILED MOVEMENT JOINTS PER TCNA; FLOOR TO WALL PERIMETER, WALL TO CEILING PERIMETER, INSIDE CORNERS (TILE TO
TILE), OUTSIDE CORNERS (TILE TO TILE AND/OR TILE TO SCHLUTER TRIM).
O. FLOOR FINISH PLAN MAY NOT INDICATE FLOORING UNDER OPEN COUNTERTOPS/CABINETRY/EQUIPMENT/MISCELLANEOUS; REFERENCE ELEVATION DRAWINGS AND EQUIPMENT/FURNITURE
PLANS.
P. COVE BASE HAS STANDARD HEIGHT OF 6" U.N.O.
Q. INSTALL SCHLUTER TRIM AT ALL OUTSIDE CORNERS AND TOP OF TILE, U.N.O. ON ELEVATIONS.
R. INSTALL WINDOW TREATMENT WT-1 ALL WINDOWS, U.N.O. ON FINISH SCHEDULE.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY
TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS. PRODUCTS OF
OTHER MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES
AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF
TECHNICAL SPECIFICATIONS WILL BE ACCEPTABLE UPON APPROVAL IN
WRITING BY CONTRACTING OFFICER FOR FINISH REQUIREMENTS.
- THIS NOTE APPLIES TO ALL SUCH INSTANCES IN THE DRAWINGS AND
SPECIFICATIONS FOR THIS PROJECT.
METAL TRIM MT-1
BUILD UP ADJOINING
MATERIAL WITH
CEMENTITIOUS
MORTART TO BE FLUSH
WITH TOP OF EDGE
WELDED SHEET
FLOORING
TILE
MAX. SLOPE 1:12
M A
X
/2
DOOR FRAME
BEYOND
FABRICATE DOOR TO
ACCOMMODATE
FLOOR SLOPE
F
IE
L D
V F
Y
/4
PORCELAIN TILE
BOND COAT
CEMENTITIOUS BACKER UNIT
MT-2
WATERPROOFING
MEMBRANE; TURN
UP WALL MIN. 4"
CUT OUT CONC. AS REQ'D FOR
FLOOR DRAIN; SEE MECH.
WEEP HOLES WITH
PEA GRAVEL
BOND COAT
FLEXIBLE SEALANT
SLOPED MORTAR BED;
SLOPE MIN. 1/8 INCH PER FOOT
A
2 3 4 5 6
B
C
D
1 2 3 4 5 6
A
B
C
D
VA FORM 08-6231
o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t
CONSULTANTS: ARCHITECT/ENGINEERS:
Drawing Title
Office of Construction and Facilities ManagementApproved: Project Director
Project Title
Location
Date Checked Drawn
Dwg.
Drawing Number
Building Number
Project Number
Department of Veterans Affairs
600 EAST 7TH STEET
SIOUX FALLS, SOUTH DAKOTA 57103
605.274.2893
6 SOUTH OLD ORCHARD
ST. LOUIS, MISSOURI 63119
800.404.7677
330 N MEAD
WICHITA, KANSAS 67202
316.262.2500
AI101
FINISH SCHEDULE
RELOCATE PHYSICAL
MEDICINE & REHAB. TO THE
4TH FLOOR
800 HOSPITAL DRIVE COLUMBIA, MO 65201
02-15-2023
589A4-22-100
BID DOCUMENTS
ALHJHK
FINISH SCHEDULE
RM # ROOM NAME FLOOR BASE
WALLS CEILING
KEYED NOTESN. E. S. W. TYPE
400 ELEV. LOBBY / CORR. WSF-1 WB-1 RWC-5 P-1 P-1 P-1 ACT-1/GWB P-4 SOFFIT CONNECTED TO 405A
401 ELEV. LOBBY WSF-1 RB-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 RWC-1/P-1 ACT-1 3'H RWC
401A SOILED DISP WSF-1 WSF-1 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 ACT-2 3'H HWC
402 WOMEN'S TLT PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 ACT-1 5'-2"H WAINSCOT
403 MEN'S TLT PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 ACT-1 5'-2"H WAINSCOT
404 WC STOR./SHOP WSF-2 RB-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 ACT-1 3'H RWC
404A STG. WSF-2 RB-1 P-1 P-1 P-1 P-1 EXPOSED
405 PROST. STOCK RM. WSF-2 RB-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 ACT-1 3'H RWC
405A PROST. CHECKIN WSF-2 RB-1 P-1 P-1 P-4 P-1 ACT-1/GWB P-4 SOFFIT CONNECTED TO
410 PROST. WAIT. WSF-1 RB-1 RWC-3/P-1 - - RWC-3/P-4 ACT-1/ACT-4 3'H RWC; SEE RCP FOR
ACT-4 LOCATIONS
411 FITTING/EXAM RM. WSF-2 RB-1 P-1 P-1 P-1 P-5 ACT-1
412 FITTING/EXAM RM. WSF-2 RB-1 P-1 P-1 P-1 P-5 ACT-1
413 PROST. PURCHASING WSF-1 RB-1 P-1 P-4 P-1 P-1 ACT-1
414 STAFF TLT. PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 ACT-1 5'-2"H WAINSCOT
415 PROST. REP WSF-1 RB-1 P-4 P-1 P-1 P-1 ACT-1
416 PROST. CHIEF WSF-1 RB-1 P-4 P-1 P-1 P-1 ACT-1
417 PROST. ASST. CHIEF WSF-1 RB-1 P-4 P-1 P-1 P-1 ACT-1
418 ELEC. CONC RB-1 P-1 P-1 P-1 P-1 EXPOSED
419 FITTING/EXAM RM. WSF-2 RB-1 P-4 P-1 P-1 P-1 ACT-1
420 ANTE WSF-2 WSF-2 P-1 P-1 P-1 P-1 ACT-1
421 DUST RM. WSF-2 WSF-2 P-1 P-1 P-1 P-1 ACT-1
421A MAINT. WSF-2 WSF-2 P-1 P-1 P-1 P-1 ACT-1
422 FUME RM. WSF-2 WSF-2 P-1 P-1 P-1 P-1 ACT-1
423 PLASTER CONC RB-1 HWC-1 HWC-1 HWC-1 HWC-1 ACT-1 FULL-HEIGHT HWC
424 CLEAN LAB WSF-2 WSF-2 P-1 P-1 P-1 P-1 ACT-1
425 PER. CLNC. GROUP RM. WSF-2 RB-1 P-1 RWC-2/P-5 P-1 RWC-2/P-1 ACT-1 SEE WALL PROTECTION
PLAN FOR RWC-2
LOCATION. WT-2 ALL
WINDOWS THIS ROOM
426 PER. CLNC. MASSAGE WSF-2 RB-1 P-1 RWC-2/P-5 P-1 RWC-2/P-1 ACT-1 SEE WALL PROTECTION
PLAN FOR RWC-2
LOCATION. WT-2 ALL
WINDOWS THIS ROOM
426A STOR. WSF-2 RB-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 GWB/P-2 3'H RWC
430 CHIRO. EXAM WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
431 CHIRO. EXAM WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
432 ACUPUNCTURE WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
433 ACUPUNCTURE WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
434 PELVIC WSF-2 RB-1 P-1 P-1 P-1 P-5 ACT-1/ACT-3 SEE RCP FOR ACT-3
LOCATION
435 PELVIC WSF-2 RB-1 P-1 P-1 P-1 P-5 ACT-1/ACT-3 SEE RCP FOR ACT-3
LOCATION
436 PT/OT EXAM WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
437 PT TLT. PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 GWB/SC-2 5'-2"H WAINSCOT
438 PT/OT EXAM WSF-2 RB-1 P-1 P-5 P-1 P-1 ACT-1
439A CLO. EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING PATCH EXISTING FINISHES
AS REQUIRED
440 OT TRAIN. RM. WSF-2 RB-1 P-1 P-1 P-5 P-1 ACT-1
440A OT TLT. PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 ACT-1 5'-10"H WAINSCOT
445 OI&T RM. EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXPOSED PATCH EXISTING FINISHES
AS REQUIRED
450 PT GYM WSF-2/WSF-3 RB-1 P-1 P-1 P-5 P-1 ACT-1/GWB GWB SOFFIT AT ALCOVE.
SEE FINISH PLAN FOR WSF
AND ADDITIONAL PAINT
COLOR LOCATIONS.
450A CLEAN LINEN WSF-2 WSF-2 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 ACT-2 3'H HWC
451 PT/OT EXAM BARIATRIC WSF-2 RB-1 P-5 P-1 P-1 P-1 ACT-1
452 PT/OT STOR. WSF-2 RB-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 RWC-2/P-1 ACT-1 3'H RWC
453 ELEC. EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXPOSED PATCH EXISTING FINISHES
AS REQUIRED
455 WAIT. WSF-1 RB-1 - RWC-4/P-1 RWC-4/P-1 RWC-4/P-5 ACT-1/ACT-5 3'H RWC; SEE RCP FOR
ACT-5 LOCATIONS
460 PT/OT SWAMP WSF-1 RB-1 P-1 P-1 P-4 P-1 ACT-1
461 REHAB. COOR. WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
462 STAFF TLT. PT-1 PT-1 PT-2/P-3 PT-2/P-3 PT-2/P-3 PT-2/P-3 ACT-1 5'-2"H WAINSCOT
463 TELE HEALTH WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
464 PSA WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
465 OT SUPER. WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
466 AO WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
467 CHIEF PM&R EXAM WSF-2 RB-1 P-1 P-1 P-1 P-5 ACT-1
468 BREAK RM. WSF-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
469 HSKPG. WSF-2 WSF-2 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 HWC-1/SC-1 ACT-2 3'H HWC
470 MSA CHECKIN/OUT WSF-1 RB-1 P-5 P-1 P-1 P-1 ACT-1/GWB P-5 SOFFIT CONNECTED TO
C41
C41 CORR. WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1 P-5 SOFFIT CONNECTED TO
C42 CORR. WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
C43 CORR. WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
C44 CORR. WSF-2 RB-1 P-1 P-1 P-1 P-1 ACT-1/P-1 GWB SOFFIT AT ALCOVE
C45 CORR. WSF-2 RB-1 P-1 P-1 P-1 P-1 ACT-1
C46 CORR. WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
C47 CORR. WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
Grand total: 65
COLOR SCHEDULE KEY
CODE DESCRIPTION MANUFACTURER STYLE NAME STYLE / COLOR SIZE / TYPE SPECIAL INFO / NOTES
ACT-1 ACOUSTIC CEILING TILE ARMSTRONG MESA SQUARE LAY-IN #680 / WHITE 24"X24"X3/4" SQ. EDGE GRID 15/16" IN WHITE
ACT-2 ACOUSTIC CEILING TILE (SP) ARMSTRONG ULTIMA HEALTH ZONE HIGH WASHABILITY SQUARE LAY-IN #1935 / WHITE 24"X24"X3/4" SQ. EDGE GRID 15/16" IN WHITE
ACT-3 ACOUSTIC CEILING TILE CEILING SCENES ACOUSTIC CEILING TILE SCENES IMAGE: #5151 SKY & TREES; LAYOUT: C 24"X24"X3/4" SQ. EDGE AT PELVIC EXAM ROOMS; IMAGE SPANS TWO (2) TILES
ACT-4 ACOUSTIC CEILING TILE CEILING SCENES ACOUSTIC CEILING TILE SCENES IMAGE: #5128 SKY; LAYOUT: D 24"X24"X3/4" SQ. EDGE AT PROS. WAIT 410; IMAGE SPANS FOUR (4) TILES
ACT-5 ACOUSTIC CEILING TILE CEILING SCENES ACOUSTIC CEILING TILE SCENES IMAGE: #5101 SKY; LAYOUT D 24"X24"X3/4" SQ. EDGE AT WAIT 455; IMAGE SPANS FOUR (4) TILES
CG-1 CORNER GUARD (CORRIDORS) INPRO CORPORATION G2-150 SHARKSKIN #0350 3" WING
CG-2 CORNER GUARD (ROOMS) INPRO CORPORATION G2-150 EGGSHELL #0111 3" WING
CG-3 CORNER GUARD INPRO CORPORATION SURFACE MOUNT STAINLESS STEEL CORNER
GUARD
STAINLESS STEEL 2" WING
CH-1 CHAIR RAIL INPRO CORPORATION G2-2700 SHARKSKIN #0350 3" HIGH MOUNT 36" A.F.F. TO TOP
CONC SEALED CONCRETE FOUNDATION ARMOR ARMOR WB15 LOW GLOSS WATER BASED ACRYLIC
CR-1 CRASH RAIL INPRO CORPORATION G2-1400I SHARKSKIN #0350 3"H MOUNT DIRECTLY ABOVE WALL BASE
CR-2 CRASH RAIL INPRO CORPORATION G2-1400I EGGSHELL #0111 3"H MOUNT DIRECTLY ABOVE WALL BASE
GT-1 GROUT MAPEI TO BE SELECTED FROM MANUFACTURER'S
STANDARD COLORS
HR-1 HANDRAIL INPRO CORPORATION 900M ESPRESSO TO MATCH EXISTING 1-1/2" DIA MOUNT 36" A.F.F. TO TOP; USE 90955-P BRACKETS; CUSTOM COLOR, ALLOW EXTRA LEAD TIME
HWC-1 HYGIENIC WALL CLADDING INPRO CORPORATION SANI-SURFACE HYGIENIC WALL CLADDING NATURAL WHITE #0384 3'H
MT-1 METAL TRIM SCHLUTER SYSTEMS JOLLY STAINLESS STEEL INSTALLER TO VERIFY SIZE REQUIRED FLOOR TRANSITION FROM TILE TO WSF
MT-2 METAL TRIM SCHLUTER SYSTEMS DILEX ANODIZED ALUMINUM INSTALLER TO VERIFY SIZE REQUIRED INSIDE CORNERS AND FLOOR/WALL TRANSITION AT TILED WALLS
MT-3 METAL TRIM SCHLUTER SYSTEMS RONDEC ANODIZED ALUMINUM INSTALLER TO VERIFY SIZE REQUIRED OUTSIDE CORNERS AND WAINSCOT TOP EDGES AT TILED WALLS
P-1 PAINT (WALLS - TYPICAL) SHERWIN-WILLIAMS HARMONY ZERO VOC; MP1 52 WOOL SKEIN #SW6148 EGGSHELL
P-2 PAINT (GWB CEILINGS) BENJAMIN MOORE ECO SPEC WB; MPI 53 PAPER WHITE #OC-55 FLAT
P-3 PAINT (TOILET WALLS) BENJAMIN MOORE ECO SPEC WB; MPI 54 GULL WING GRAY #2134-50 SEMI-GLOSS
P-4 PAINT (ACCENT WALLS) BENJAMIN MOORE ECO SPEC WB; MP1 52 ADIRONDACK GREEN #453 EGGSHELL
P-5 PAINT (ACCENT WALLS) BENJAMIN MOORE ECO SPEC WB; MP1 52 SEA REFLECTIONS #1664 EGGSHELL
P-6 PAINT (HM FRAMES) SHERWIN WILLIAMS ECO SPEC WB; MPI 141 REPOSE GRAY #SW7015 SEMI-GLOSS VERIFY AND MATCH ADJACENT CLINIC
PL-1 PLASTIC LAMINATE (CABINETRY) LAMINART ITALIAN CHERRY #3061
PT-1 PORCELAIN TILE (FLOORS AND BASE) STONEPEAK SKY GREENSKY 12"X24" FLOOR; 6"X12" BASE INSTALL METHOD: RUNNING BOND 1/3 OFFSET
PT-2 PORCELAIN TILE (WALLS) DALTILE UNIFORM WOOD LIGHT GREY #UW12 8"X48" INSTALL METHOD: RUNNING BOND 1/2 OFFSET (VERIFY AND MATCH
EXISTING)
RB-1 RESILIENT BASE TARKETT RUBBER; TRADITIONAL TOE PEBBLE #32 6"H
RWC-1 RIGID WALL COVERING (CORRIDORS) INPRO CORPORATION PALLADIUM G2 SHARKSKIN #0350 3'H; EMBOSSED TEXTURE
RWC-2 RIGID WALL COVERING (ROOMS) INPRO CORPORATION PALLADIUM G2 EGGSHELL #0111 3'H; EMBOSSED TEXTURE
RWC-3 RIGID WALL COVERING (WAITING RM) INPRO CORPORATION ASPEX WALL PROTECTION PATTERN: DRIFT; COLOR: SOFT GREEN #A015
3'H; MATTE FINISH
RWC-4 RIGID WALL COVERING (WAITING RM) INPRO CORPORATION ASPEX WALL PROTECTION PATTERN: DRIFT; COLOR: BLUE GREY #A013
3'H; MATTE FINISH
RWC-5 RIGID WALL COVERING INPRO CORPORATION PALLADIUM BEVELED EDGE PANEL AMBER CHERRY #0547 ANODIZED ALUMINUM REVEAL STRIP PER HSTVA. REFER TO
INTERIOR FINISHES MASTER PLAN (AVAIL. FROM COLUMBIA VA) FOR
ADD'L INFO. BRING ELEVATOR CALL BUTTONS AND INDICATORS OUT
TO FACE OF NEW PANEL SYSTEM.
RWC-6 RIGID WALL COVERING INPRO…
This is the start of the file's text. The full file is on GovTribe.