Drawings-589A4-22-100-2023-02-15 BID Set- Part5-pages 10.pdf

PDF 4 MB Posted

Attached to
Z2DA-- Relocate Physical Medicine and Rehabilitation to the 4th Floor PN: 589A4-22-100
Solicitation number
36C25523R0072
Issued by

About this file

This set of construction drawings and specifications is for a project to relocate physical medicine and rehabilitation services to the fourth floor at a Department of Veterans Affairs medical center. The project scope includes demolishing portions of an existing fire sprinkler system and fire alarm system, and installing new systems to cover the affected areas. The fire sprinkler work will provide wet pipe sprinkler protection meeting NFPA 13 requirements for light and ordinary hazard classifications. It will also involve connecting to existing sprinkler mains and maintaining coverage in occupied areas during phasing. The fire alarm work includes removing outdated devices and installing a new addressable system integrated with the existing facility-wide network. Construction is planned in phases to minimize disruptions to medical services.

View the file

Other files

File Type Posted
36C25523R0072 0004.docx DOCX document
AMENDMENT 3 - Drawings.pdf PDF
AMENDMENT 3 - Specifications.pdf PDF
36C25523R0072 0003.docx DOCX document
Prebid-site visit attendee list.pdf PDF
36C25523R0072 0002.docx DOCX document
589A4-22-100 Volume 2 Specifications- 494 pages.pdf PDF
36C25523R0072 0001.docx DOCX document
Drawings-589A4-22-100-BID Set -2-15-2023- Part1-7 pages.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set -Part4-pages 10.pdf PDF
36C25523R0072.docx DOCX document
Drawings-589A4-22-100-2023-02-15 BID Set - Part12-pages 11.pdf PDF
Drawings-589A4-22-100- 2023-02-15 BID Set-Part2- Pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part13-pages 1.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part6-pages 6.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set- Part9-pages 8.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set - Part3-pages-12.pdf PDF
Specifications-589A4-22-100-2023-02-15 BID Set - VOL 1- Pages 785.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part8-pages 9.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part11-pages 9.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID Set-Part10-pages 13.pdf PDF
Drawings-589A4-22-100-2023-02-15 BID set - Part7-pages 9.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FOURTH FLOOR KEY PLAN

N

CHIRO. EXAM

ACUPUNCTURE

ACUPUNCTURE

PT/OT EXAM

PT/OT EXAM

PELVIC

PELVIC

PT/OT EXAM

BARIATRIC

PT/OT STOR.

PT TLT.

PROST.

STOCK RM.

PT GYM

AO

OT SUPER.

BREAK RM.

STAFF TLT.

REHAB.

COOR.

PSA

PT/OT

SWAMP

CHIEF PM&R

EXAM

WAIT.

OT TRAIN.

RM.

OT TLT.

440A

CRASH CART

ALCOVE

ELEC.

WC

STOR./SHOP

CLEAN LINEN

450A

EQUIP.

CORR.

C43

CORR.

C44

ELEV. LOBBY

SOILED DISP

401A

TELE

HEALTH

R.1

A

R

CORR.

C45

STG.

404A

R

R.1

R

PROST.

CHECKIN

405A

H F1

R

R

R

R

R

R

R

R

R

E

B

R R

R

CLO.

439A

R.1

R

R

C

R R

R.1

R

R

R

A

A

R

R

B

E

R

R

R

R

R

R

F

CORR.

C42

R

F

S.1G

S

F

REMOVE AND REINSTALL

EXISTING SIGNS (2 THUS)

A: F:

Fire Extinguisher

DOOR MOUNT

9"

Authorized Personnel Only

1' - 0"

BACKGROUND COLOR:

CSS OFF-WHITE,

BOLD COPY COLOR:

BLACK

S:

STAIR #

9"

SIGN LEGEND

C:

Crash Cart

FLAG WALL MOUNT

9"

3/8" RADIUS

CORNERS

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: FIRE RED,

GRAPHIC & COPY

COLOR: WHITE

" BABY CHANGING

STATION

E:

FLAG WALL MOUNT

9"

1" X 1/32" BOLD COPY

Z:

WALL MOUNT

9"

BIOHAZARD

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: ORANGE,

GRAPHIC & COPY

COLOR: BLACK

WALL MOUNT

3/8" RADIUS

CORNERS

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: FIRE RED,

GRAPHIC & COPY

COLOR: WHITE

K:

FLAG WALL MOUNT

STAIR #

9"

1" X 1/32" ADA TACTILE

BOLD COPY & GRADE 2

BRAILLE

S.1:

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER 2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND &

MARGIN COLOR:

METALLIC SILVER,

GRAPHIC & BOLD

COPY COLOR: BLACK

E.1:

FLAG WALL MOUNT

9"

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

3/8" RADIUS

CORNERS

SEE SIGNAGE

SCHEDULE FOR MALE

& FEMALE LOCATIONS

9"

WALL MOUNTED

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

3/8" RADIUS

CORNERS

RESTROOM RESTROOM

WALL MOUNT

9"

1" X 1/32" ADA TACTILE

BOLD COPY & GRADE 2

BRAILLE

B:

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

RESTROOM

WALL MOUNT

9"

1" X 1/32" ADA TACTILE

BOLD COPY & GRADE 2

BRAILLE

B.1:

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: DARK BLUE,

GRAPHIC & COPY

COLOR: SILVER

RESTROOM SEE SIGNAGE

SCHEDULE FOR MALE

& FEMALE LOCATIONS

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

RAISED SYMBOL

9"

ROOM #

R.1:

WALL OR DOOR MOUNT

ROOM NAME

1" X 1/32" ADA TACTILE

BOLD NUMERALS AND

GRADE 2 BRAILLE,

COPY COLOR: BLACK

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: METALLIC

SILVER

UPPER/LOWER PANELS -

MAGNETICALLY

REMOVEABLE F-UNIT

WALL MOUNT

OR GLASS MOUNT

R:

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED

BACKGROUND COLOR -

METALLIC SILVER

5-3/16" X 9" CLEAR

ACETATE INSERT

BOLD BLACK COPY

GRAPHIC WATERMARK

"WAVING US FLAG" ON

1/16" CLEAR ACRYLIC

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

9"

ROOM #

1" X 1/32" ADA TACTILE

BOLD NUMERALS AND

GRADE 2 BRAILLE,

COPY COLOR: BLACK

2 PLY NON-GLARE

ACRYLIC

CONSTRUCTION

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: METALLIC

SILVER

SQUARE SATIN SILVER

ANODIZED ALUMINUM

FRAME WITH 75%

RECYCLED CONTENT

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

1" X 1/32" BOLD COPY

FLAG WALL MOUNT

G:

FLAG WALL MOUNT

9"

3/8" RADIUS

CORNERS

3 PLY NON-GLARE

ACRYLIC

CONSTRUCTION.

SUBSURFACE UV

VARIABLE DOT

DIGITALLY PRINTED,

BACKGROUND

COLOR: WHITE.

GRAPHIC & COPY

COLOR: VA TO

VERIFY

VA TO CONFIRM

GRAPHIC &

COPY

SIGNAGE NOTES

1. SIGN LOCATION ID DISTINGUISHED WITH SIGN TAG NUMBER EQUAL TO THE ROOM NUMBER AND SIGN TYPE (EX: A313-P)

2. REFERENCE GRAPHICAL SIGN ILLUSTRATIONS FOR SIGNAGE REQUIRING ROOM NUMBERS.

3. VA, ARCHITECT, CONTRACTOR, AND SIGNAGE SUPPLIER TO MEET AND AGREE ON SIGNAGE COPY/MESSAGE/TEXT PRIOR TO SIGNAGE SUBMITTAL

DOCUMENTS FOR APPROVAL.

4. SIGNAGE SUBMITTAL TO INCLUDE VISUAL GRAPHIC OF EACH INDIVIDUAL SIGN IN PROJECT.

5. WALL MOUNTED SIGNS TO BE MECHANICALLY FASTENED TO WALL.

6. SIGNAGE DESIGN AND MATERIALS TO MATCH EXISTING HSTVA SIGNAGE STANDARDS, REF SPEC.

7. ALL SIGNAGE TO BE IN COMPLIANCE WITH ADA & ABA ACCESSIBILITY STANDARDS FOR FEDERAL FACILITIES.

8. SQUARE SATIN ANODIZED ALUMINUM FRAME.

9. SIGN COMPANY TO PURCHASE ALL GRAPHIC IMAGES FOR THE HOSPITAL. SIGN COMPANY RESPONSIBLE FOR MODIFYING BACKGROUND ON IMAGES.

10. SIGN COMPANY TO PROVIDE OWNER WITH SOFTWARE, PRINTER, MATERIALS & INSTRUCTIONAL CLASS ON HOW TO UPDATE CHANGEABLE SIGNS.

11. SIGN COMPANY TO PROVIDE DISC OF TEMPLATE LAYOUT DRAWINGS, COLOR, AND TYPOGRAPHY SPECS FOR ALL CHANGEABLE SIGNS INCLUDING DIRECTORY, DIRECTIONALS, AND OVERHEADS.

12. SIGNAGE INSTALLER TO COORDINATE LOCATIONS OF CEILING HUNG SIGNS WITH FIRE PROTECTION SPRINKLER HEADS ACCORDING TO NFPA REGULATIONS.

13. SIGNAGE MOUNTED TO GLASS SHALL HAVE BLANK FACE PLATE ON OPPOSITE SIDE TO CONCEAL ATTACHMENT METHOD.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig h th in c o n e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e rs e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e s e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

Department of Veterans Affairs

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

AI603

SIGNAGE PLAN - 4TH FLOOR - AREA B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

ALHJHK

3/16" = 1'-0" D2

SIGNAGE PLAN - 4TH FLOOR - AREA B

N

0' 2'-8" 5'-4" 10'-8"

# Revision Date

COMMON PIPING SYMBOLS &

ABBREVIATIONS

NOT ALL SYMBOLS ARE USED FOR THIS PROJECT

DIRECTION OF FLOW

BRANCH CONNECTION, BOTTOM

BRANCH CONNECTION, TOP

ELBOW, TURNED DOWN

ELBOW TURNED UP

SHUTOFF VALVE

CHECK VALVE

PRESSURE REDUCING VALVE

PRESSURE GAUGE

UNION

PIPING CAP

RISER DESIGNATION

ABOVE FINISH FLOOR

AUTHORITIES HAVING JURISDICTION

ACCESS PANEL

BOTTOM OF PIPE

DIAMETER

DOWN

EXISTING

FINISHED FLOOR ELEVATION

GALLONS PER HOUR

GALLONS PER MINUTE

HORSEPOWER

INVERT ELEVATION

NORMALLY CLOSED

NOT TO SCALE

POUNDS PER SQUARE INCH

REVOLUTIONS PER MINUTE

ROUGH-IN

SHUTOFF VALVE

TOTAL DYNAMIC HEAD

VERIFY IN FIELD

AFF

AHJ

AP

BOP

DIA

DN

EX OR EXIST

FFE

GPH

GPM

HP

IE OR INV. ELEV

NC

NTS

PSI

RPM

RI

SOV

TDH

VIF

X

PLAN MARK

EQUIPMENT NUMBER

SHEET NUMBER

LINE TYPE LEGEND

DRAWING REFERENCES

NEW WORK BY THIS CONTRACTOR

(DARK, SOLID LINE)

EXISTING TO REMAIN OR NEW WORK BY OTHERS

(LIGHT, SOLID LINE)

EXISTING TO BE REMOVED BY THIS CONTRACTOR

(DARK, DASHED LINE, DEMOLITION PLANS)

NEW WORK BY THIS CONTRACTOR TO BE

INSTALLED UNDERGROUND, OR BELOW FLOOR

(DARK, LONG DASHED LINE)

NORTH ARROW

PLAN DETAIL REFERENCE TITLE

KEYED NOTE DESIGNATION

PLAN MARK

EQUIPMENT NUMBER

EQUIPMENT DESIGNATION REFER TO MEP

SCHEDULE FOR CIRCUITING AND DEVICE

REQUIREMENTS AND FLOOR PLANS FOR

LOCATIONS

ENLARGED PLAN REFERENCE

PLAN MARK

SHEET NUMBER

A101

SIM

AHU

TITLE

SCALE

PLAN

NORTH

TRUE

NORTH

INTERFACE, EXISTING TO NEW

EXTENT OF DEMOLITION

SECTION

MATCHLINE

1 REVISION TAG

AD888

FIRE PROTECTION GENERAL NOTES

1. ALL WORK SHALL BE PERFORMED, INSTALLED, AND TESTED IN COMPLIANCE WITH THE CODES AND AMENDMENTS ADOPTED BY THE INSPECTION AUTHORITY. NOTHING IN THESE PLANS IS TO BE CONSTRUCTED TO

PERMIT WORK NOT CONFORMING TO THESE CODES OR OTHERS APPLICABLE TO THIS PROJECT:

A. 2018 - IFC

B. 2018 - IBC

C. VA DESIGN MANUAL - EIGHTH EDITION

D. OCCUPATIONAL SAFETY AND HEALTH ACT (OSHA)

E. NATIONAL FIRE PROTECTION ASSOCIATION EDITIONS LISTED IN THE IBC OR MOST CURRENT EDITIONS OF

THE FOLLOWING

a. NFPA 13

b. NFPA 25

2. THE WORK CONSISTS OF FURNISHING ALL LABOR AND MATERIALS NECESSARY TO INSTALL, COMPLETE AND READY CONTINUOUS OPERATION, THE FIRE PROTECTION SYSTEMS, APPARATUS AND EQUIPMENT FOR THIS PROJECT, AS SHOWN ON THE DRAWINGS, PLUS AS REQUIRED BY NFPA 13 AND THE AUTHORITY HAVING

JURISDICTION (AHJ).

3. THE CONTRACTOR SHALL INCLUDE IN THEIR BID, A FULLY CODE COMPLIANT AND COORDINATED SPRINKLER SYSTEM. PROJECT SHALL BE DESIGNED, CONSTRUCTED, AND TESTED PER THE NFPA STANDARDS AND/OR FM

GLOBAL REQUIREMENTS.

4. THESE DRAWINGS ARE ACCURATE TO THE BEST OF OUR KNOWLEDGE, HOWEVER, LOCATIONS, DEPTHS, ELEVATIONS AND SIZES WERE TAKEN FROM DIFFERENT SOURCES AND ARE SUBJECT TO DEVIATION. THE CONTRACTOR SHALL ASSUME SOME DEVIATIONS AND INCLUDE OFFSETS, ADDITIONAL PIPING, ETC AT THE TIME

OF BID.

5. ALL SYSTEMS, EQUIPMENT, AND MATERIALS ARE TO BE INSTALLED IN A NEAT WORKMAN LIKE MANNER, WORK

NOT DONE SO SHALL BE REMOVED AND REINSTALLED SATISFACTORILY.

6. THE FIRE PROTECTION BID IS A DESIGN/BUILD CONTRACT. BEFORE SUBMITTING THE BID, THE CONTRACTOR SHALL VISIT THE SITE AND BECOME THOROUGHLY FAMILIAR WITH ALL EXISTING CONDITIONS AND VERIFY LOCATIONS, ELEVATIONS, AND SIZES OF ALL UTILITIES AT SITE PRIOR TO PROCEEDING WITH WORK. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY ASSUMPTIONS, OMISSIONS, OR ERRORS MADE AS A RESULT OF THE FAILURE TO BECOME FULLY FAMILIAR WITH EXISTING CONDITIONS. EXISTING SYSTEMS AND STRUCTURE SHALL BE INVESTIGATED FOR BEST POSSIBLE ROUTING OF FIRE PROTECTION PIPING.

7. WHEN PLACING NEW SPRINKLERS AND ROUTING NEW SPRINKLER PIPING, CONTRACTOR SHALL VERIFY LOCATIONS OF POTENTIAL OBSTRUCTIONS FROM MECHANICAL EQUIPMENT AND ARCHITECTURAL FEATURES

PRIOR TO BID AND PRICE ACCORDINGLY TO MAKE ALLOWANCES IN BID.

8. THE CONTRACTOR SHALL PROVIDE HYDRAULIC CALCULATIONS BASED UPON THE MOST CURRENT FIRE PUMP

TEST RESULTS TO BE PROVIDED BY THE FACILITY UPON REQUEST.

9. AT LEAST ONE HYDRAULIC CALCULATION SHALL BE PROVIDED PER SPRINKLER ZONE BASED ON THE CURRENT FLOW TEST. THE CALCULATION WILL INCLUDE HOSE ALLOWANCES AT THE BASE OF THE RISER PER NFPA 13 REQUIREMENTS BASED ON THE IDENTIFIED HAZARD. THERE WILL BE A 10% SAFETY ALLOWANCE PROVIDED FOR THE SPRINKLER SYSTEM BASED ON THE AVAILABLE PRESSURE AT THE SOURCE AND SYSTEM DEMAND. (10% OF

THE SUM OF THE SPRINKLER DEMAND PLUS THE SAFETY FACTOR).

10. THE CONTRACTOR SHALL SUBMIT ALL DRAWINGS AND CALCULATIONS TO THE FIRE DEPARTMENT, GOVERNING AGENCIES, AND INSURING AGENCY AND RECEIVE APPROVAL PRIOR TO SUBMITTING DESIGN SHOP DRAWINGS.

11. SUBMIT ACCURATE AS-BUILT DRAWINGS TO THE ENGINEER AND OWNER.

12. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THESE PLANS OR IS NOT COMPLETELY SURE OF THEIR

MEANING, THIS CONTRACTOR SHOULD OBTAIN THE ENGINEER’S WRITTEN EXPLANATION AND/OR

INTERPRETATION PRIOR TO SUBMITTING BIDS, SINCE THIS CONTRACTOR WILL BE HELD RIGIDLY TO THE

INTERPRETATION OF THE ENGINEER.

13. THESE PLANS ARE DIAGRAMMATIC IN NATURE SINCE THE ONLY AVAILABLE INFORMATION HAS BEEN OBTAINED FROM EXISTING PLANS, SPECIFICATIONS, AND FILED SURVEYS. THE EXACT LOCATION OF PIPING AND EQUIPMENT MAY DEVIATE FROM THE LOCATION INDICATED BY THESE DRAWINGS. EXTREME ACCURACY IS NOT GUARANTEED. THIS CONTRACTOR SHALL BE PREPARED TO MAKE ALTERATIONS TO EXISTING SERVICES TO FIT JOB CONDITIONS. THIS CONTRACTOR SHALL REPORT, IN WRITING, ANY DISCREPANCIES WHICH PREVENT THE

INSTALLATION OF WORK AS SHOWN.

14. IT IS ASSUMED THAT AREAS OUTSIDE THE SCOPE OF WORK ARE TESTED, MAINTAINED, AND MEET THE CODE REQUIREMENTS WHEN IT WAS INSTALLED, AND THE EXISTING SYSTEM IS ACCEPTED BY THE LOCAL AHJ. WORK PERFORMED WITHIN SCOPE OF WORK WILL PROVIDE A SYSTEM TO MEET THE REQUIREMENTS SET BY THE AHJ

LIMITED BY THE BOUNDARY OF WORK.

15. THE SPRINKLER CONTRACTOR PRIOR TO TIME OF BID SHALL EVALUATE THE SITE AND VERIFY ALL SPRINKLER PIPING AND EQUIPMENT THAT IS EXISTING TO REMAIN WITHIN OR SERVING THE SCOPE OF WORK, IS IN GOOD

WORKING CONDITION.

16. FURNISH AND INSTALL TAMPER SWITCHES ON ALL INDICATING VALVES AND FLOW SWITCHES PER NFPA 13

REQUIREMENTS AND PER THE DESIGN DOCUMENTS BY THE CONTRACTOR.

17. THE CONTRACTOR SHALL FURNISH DRAIN VALVES AND INSPECTOR’S TEST CONNECTIONS AS REQUIRED BY NFPA 13 REQUIREMENTS AND AT THE DISCRETION OF THE FIRE MARSHAL, ENGINEER OR GOVERNING AGENCY.

18. ALL OPENINGS THROUGH FIRE RATED FLOORS, WALLS, OR PARTITIONS SHALL BE FIRE STOPPED WITH UL RATED ASSEMBLIES OF EQUAL OR GREATER FIRE RATING. REFER TO FIRE STOPPING NOTES FOR ADDITIONAL

INFORMATION.

19. COORDINATE WITH STRUCTURAL ENGINEER WHEN SAW-CUTTING THROUGH CONCRETE FLOOR OR WALL CONSTRUCTION. LEAVE SUFFICIENT REBAR EXPOSED TO TIE NEW REINFORCING REPLACEMENT CONCRETE

AND/OR OTHER STRUCTURAL ATTACHMENTS FOR NEW CONSTRUCTION.

20. VALVES, TAMPER SWITCHES, OR ANY MECHANICAL/ELECTRICAL ITEM SHALL NOT BE LOCATED ABOVE A HARD CEILING, UNLESS PROVIDED WITH EQUIVALENTLY RATED ACCESS AND SIGNAGE MEETING NFPA 13

REQUIREMENTS.

21. SPRINKLERS SHALL BE LOCATED IN THE CENTER OF CEILING TILES, COORDINATE FINAL LAYOUT WITH

ARCHITECT, AND OTHER DISCIPLINES.

22. EXTENDED COVERAGE SPRINKLERS ARE NOT PERMITTED.

23. THE SPRINKLER CONTRACTOR SHALL OBTAIN AND UTILIZE THE ARCHITECTURAL REFLECTED CEILING PLAN FOR THE LOCATING OF SPRINKLER HEADS. REFER TO MECHANICAL AND ELECTRICAL DRAWINGS FOR CEILING

DEVICE LOCATIONS AND THE SPECIFICATIONS FOR COORDINATION DRAWING REQUIREMENTS.

24. PIPING SHALL BE INSTALLED AT LEAST 12” ABOVE FINISHED CEILING ELEVATION TO ALLOW FOR SUITABLE

ACCESS ABOVE CEILING.

25. INSTALL NO PIPING IN A LOCATION OR MANNER WHICH WILL ALLOW FREEZING.

26. COORDINATE PIPE ROUTING NEAR ELECTRICAL EQUIPMENT PER NFPA 70. PIPING IS NOT TO BE ROUTED ABOVE ELECTRICAL PANELS, TRANSFORMERS, COMPUTER RACKS ETC. FIELD VERIFY AND COORDINATE WITH ELECTRICAL CONTRACTOR ALL EXISTING AND NEW ELECTRICAL LOCATIONS PRIOR TO DESIGN OF THE FIRE

PROTECTION PLANS.

27. ROUTING OF SPRINKLER MAINS, BRANCHLINES, AND HEADS SHALL BE THOROUGHLY COORDINATED WITH ALL OTHER DISCIPLINES AND BUILDING STRUCTURE PRIOR TO SUBMISSION OF COORDINATED SHOP DRAWINGS.

THIS IS OF THE UTMOST IMPORTANCE ESPECIALLY WHERE SPACE IS LIMITED. FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR COORDINATING, PREPARING, AND SUBMITTING COORDINATION DRAWINGS FOR

APPROVAL/REVIEW.

28. ADVISE THE ENGINEERS OF ANY CONFLICTS, ERRORS, OMISSIONS, ETC. AT LEAST [10] DAYS PRIOR TO BID DATE, TO ALLOW CLARIFICATION BY WRITTEN ADDENDUM.

29. SPRINKLER CONTRACTOR TO AVOID ROUTING PIPE THROUGH SHEAR WALLS. ANY SHEAR WALL PENETRATIONS SHALL BE COORDINATED WITH THE STRUCTURAL ENGINEER. REFER TO STRUCTURAL DRAWINGS FOR SHEAR

WALL LOCATIONS.

30. THE FIRE SERVICE LEAD-IN, BACKFLOW PREVENTER, AND FIRE DEPARTMENT CONNECTION ARE EXISTING TO

REMAIN.

31. WHEN WORK REQUIRES TEMPORARY INTERRUPTIONS OF FIRE PROTECTION SERVICES OR UTILITIES THE

FOLLOWING ACTIONS WILL BE TAKEN:

A. COORDINATION WITH MAINTENANCE PERSONNEL TO SHUT OF SERVICES AT NEAREST MAIN.

B. PROVIDE TEMPORARY AND ACCESSIBLE ISOLATION VALVES CLOSE TO THE POINT OF WORK.

C. ENSURE BUILDING OPERATIONS CONTINUE WITH MINIMAL INTERRUPTIONS AND OPERATION OF EXISTING

SYSTEMS BE INTERFACED WITH AS LITTLE DISRUPTION AS POSSIBLE EXCEPT IN VACATED AREAS.

D. WORK INTERFERING WITH OPERATION OF DOWNTIME WILL BE SCHEDULED AFTER CONSULTATION WITH

AND PERMISSION GIVEN BY OWNER 10 DAYS PRIOR TO ANTICIPATED INTERRUPTION OF SYSTEMS.

E. SUCH WORK MAY BE REQUIRED TO BE PERFORMED OUTSIDE OF NORMAL WORKING HOURS.

F. REFER TO IBC FIRE WATCH REQUIREMENTS FOR DISRUPTION OF FIRE SPRINKLER SYSTEMS IN OCCUPIED

BUILDINGS WHEN DISRUPTION EXCEEDS 4 HOURS.

FIRE PROTECTION SYMBOLS & ABBREVIATIONS

NOT ALL SYMBOLS ARE USED FOR THIS PROJECT

AIR VENT (AUTOMATIC)

DOUBLE CHECK VALVE ASSEMBLY

DRY PIPE VALVE

ELECTRONIC SUPERVISED INDICATING VALVE

FIRE DEPARTMENT VALVE (FDV)

FLOW SWITCH

PREACTION VALVE

PRESSURE RELIEF VALVE

SOLENOID VALVE

DRAIN LINE

DRY PIPE

FIRE MAIN (BULK)

SPRINKLER AND SMOKE COMPARTMENT ZONE LINE

DRIP CONNECTION

FIRE DEPARTMENT CONNECTION-FREE STANDING

FIRE DEPARTMENT CONNECTION-WALL MOUNT

FLUSH TYPE FIRE DEPARTMENT INLET CONNECTION

FIRE PUMP TEST HEADER-WALL MOUNT

FIRE PUMP TEST HEADER-FREE STANDING

EXSTING SPRINKLER HEAD

EXISTING SPRINKLER HEAD TO BE REMOVED

SPRINKLER HEAD (SEE SCHEDULE FOR TYPE)

SIDEWALL SPRINKLER HEAD (SEE SCHEDULE FOR TYPE)

D

EX

EX

DRY

FP

ACCESS PANEL

AIR COMPRESSOR

AUTOMATIC SPRINKLERS

BACKFLOW PREVENTER

BRANCH TO CONNECTION

CAST IRON

DOUBLE CHECK VALVE ASSEMBLY

DRY PIPE VALVE

DRY STANDPIPE PIPING

DRY STANDPIPE VALVE

FIRE DPARTMENT CONNECTION

FIRE DEPARTMENT VALVE

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

FIRE PUMP

FIRE PUMP CONTROLLER

FIRE PUMP TEST HEADER

JOCKEY PUMP

JOCKEY PUMP CONTROLLER

NO AUTOMATIC SPRINKLERS

NOT IN CONTRACT

POST INDICATOR VALVE

SUMP PUMP

TAMPER SWITCH

AP

AC

AS

BFP

BTC

CI

DCVA

DPV

DSP

DSV

FDC

FDV

FEC

FHC

FP

FPC

FPTH

JP

JPC

NAS

NIC

PIV

SP

TS

FIRE STOPPING NOTES

1. MATERIALS: USE ONLY FIRE STOP PRODUCTS THAT HAVE BEEN UL 1479,

ASTM E-814, OR UL 2079 TESTED FOR SPECIFIC FIRE RATE CONSTRUCTION

CONDITIONS CONFORMING TO CONSTRUCTION ASSEMBLY TYPE,

PENETRATING ITEM TYPE, ANNULAR SPACE REQUIREMENTS, AND FIRE

RATING INVOLVED FOR EACH SEPARATE INSTANCE.

2. FOR SINGLE PENETRATIONS: A READY-TO-USE LATEX BASED INTUMESCENT

SEALANT IS REQUIRED TO MAINTAIN THE FIRE RATING OF THE ASSEMBLY

PENETRATED. THE SEALANT MUST HAVE UL LISTING FOR BOTH SLEEVED

AND NON-SLEEVED APPLICATIONS.

3. FOR LARGE OPENINGS: CONTAINING MULTIPLE PENETRATIONS (2 OR MORE),

A READY-TO-USE FOAM INTUMESCENT BLOCK MATERIAL MUST BE ABLE TO

BE REMOVED AND REINSTALLED WITHOUT COMPROMISING FIRE

PROTECTION INTEGRITY. COMPLY WITH MANUFACTURER'S RECOMMENDED

PROCEDURES AND PRECAUTIONS. DO NOT USE DAMAGED OR EXPIRED

MATERIALS.

4. MANUFACTURERS: JOHNS MANVILLE INTERNATIONAL, 3M BRAND, CSD

SEALING SYSTEMS, HILTI, CIBA-GEIGY, HEAVY-DUTY/NEALSON. REFER TO

DIVISION 7 FOR FURTHER REQUIREMENTS.

FIRE PROTECTION DEMOLITION NOTES

1. ALTHOUGH ALL PIPING MAY NOT BE INDICATED ON THE FLOOR PLANS, IT IS THE INTENT

THAT THE ENTIRE EXISTING SPRINKLER SYSTEM WITHIN THE SCOPE OF WORK IS TO BE

DEMOLISHED BACK TO THE FLOOR CONTROL VALVE IN THE STAIRWELL AS NOTED. ALL

PIPING HANGERS AND SUPPORTS SHALL BE REMOVED ALONG WITH THE PIPING.

2. PROTECT PIPING WHICH IS NOT TO BE REMOVED FROM DAMAGE, DIRT AND DEBRIS.

3. ALL FIRE EQUIPMENT AND MATERIALS NOT CLAIMED BY THE OWNER SHALL BE

REMOVED FROM THE PREMISES AND PROPERLY DISPOSED OF BY THE DEMOLITION

CONTRACTOR.

4. THE CONTRACTOR SHALL PLUG OR CAP ALL PIPING OUTLETS NOT INTENDED FOR

REUSE.

5. CEILING REMOVAL, STORAGE, AND REPLACEMENT WILL BE MADE BY THE CONTRACTOR

AND IT IS THE RESPONSIBILITY OF THIS CONTRACTOR TO REPAIR THE EXISTING

SURFACES TO REMAIN WHERE THEIR WORK HAS BEEN COMPLETED. REPAIR INCLUDES

BUT SHALL NOT BE LIMITED TO, ANY EXISTING WALL, CEILING, OR FLOOR THAT IS

SCHEDULED TO REMAIN. REPAIR, PAINTING, AND PATCHING SHALL BE COMPLETED BY

AN APPROPRIATE CONTRACTOR QUALIFIED FOR THIS TYPE OF WORK.

6. IF HAZARDOUS MATERIALS ARE ENCOUNTERED DURING DEMOLITION OPERATIONS, THE

CONTRACTOR WILL NOTIFY BUILDING OWNER OF THE HAZARDOUS MATERIAL.

7. ARCHITECTURAL DEMOLITION DRAWINGS AND SPECIFICATIONS SHALL BE READ IN

CONJUNCTION WITH THESE DRAWINGS.

8. THE CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH PROJECT’S PHASING

SCHEDULE PRIOR TO ANY WORK.

SCOPE

OF WORK

HOSPITAL DRIVE

M O

N K

D R

IV

E

FIRE PROTECTION PUMP TEST

PUMP RATING:

STATIC PRESSURE:

RESIDUAL PRESSURE:

FLOW:

750 GPM AT 83 PSI, 480V, 3,560 RPM

74 PSI SUCTION/170 PSI DISCHARGE

70 PSI SUCTION/150 PSI DISCHARGE

756 GPM AT 100% RATED FLOW

ADDITIONAL SAFETY

REQUIREMENTS PER AHJ:

NOTE: IT IS THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR TO VERIFY THE TEST

INFORMATION AT TIME OF BID. THE TEST INFORMATION SHALL NOT BE OLDER THAN 12 MONTHS

AT THE TIME OF SHOP DRAWING SUBMITTALS.

DATE: 07 SEPTEMBER 2022

PERFORMED BY: JIMMY HAMILTON, MAINLAND FIRE PROTECTION

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JAIME ABSHIER, PE

MO-2020010419

F-000

FIRE PROTECTION SYMBOLS AND

ABBREVIATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

SKJJMA

NOT TO SCALE

SITE PLAN

FEC

FE

F E

FEC

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

2.8

3.7

7.3

8.2

9.1

4.5

6.2

5.4

6.7

5.7

5.3

4.6

9.8

8.9

8.3

7.2

7.1

3.6

4.1

4.7

5.1

6.1

6.3

8.0

5.5

7.5

3.1

4.4

AREA A

AREA CAREA D

AREA D

1 1

FIRE PROTECTION DEMOLITION LEGEND

THERE IS NO FIRE SUPPRESSION WORK TO BE

COMPLETED IN THIS AREA. AREA IS EXISTING TO

REMAIN. CONNECT NEW SYSTEM TO EXISTING

SYSTEM WHERE INDICATED.

ALL EXISTING FIRE SPRINKLER SYSTEM COMPONENTS

TO BE DEMOLISHED IN THIS AREA INCLUDING

SPRINKLERS, PIPING, PIPE SUPPORT, AND FITTINGS.

COORDINATE WITH GENERAL CONTRACTOR FOR

PHASING AND MAINTAIN COVERAGE IN

CONSTRUCTION AREAS PER VA STANDARDS.

1. ALL FIRE SPRINKLER MAINS OUTSIDE THE SCOPE OF

WORK ARE EXISTING TO REMAIN. RECONNECT

EXISTING SPRINKLER MAINS TO NEW WORK AS

NECESSARY TO PROVIDE CONTINUOUS PROTECTION IN

ALL OCCUPIED AREAS.

2. CURRENT SPRINKLER ZONE BOUNDARY LINE. ALL

PIPING SUPPLY TO OCCUPIED AREAS ARE TO BE

MAINTAINED DURING CONSTRUCTION AND NO

SPRINKLERS IN OCCUPIED AREAS WILL BE WITHOUT

SERVICE.

SHEET KEYNOTES#

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JAIME ABSHIER, PE

MO-2020010419

FD101

FIRE PROTECTION DEMOLITION PLAN -

4TH FLOOR - OVERALL

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

SKJJMA

1/8" = 1'-0"

FIRE PROTECTION 4TH FLOOR OVERALL DEMOLITION PLAN

04 8 16268

SCALE: 1/8"=1'-0"

1. EAST ZONE 24 TO BECOME SOUTH ZONE 24 AND WILL

BE MAINTAINED BASED ON THE SMOKE COMPARTMENT

SEPARATION. SPRINKLER SYSTEM WILL NOT PROTECT

AREAS OUTSIDE OF THE DESIGNATED ZONE.

2. WEST ZONE 25 TO BECOME NORTH ZONE 2 AND WILL

BE MAINTAINED BASED ON THE SMOKE COMPARTMENT

SEPARATION. SPRINKLER SYSTEM WILL NOT PROTECT

AREAS OUTSIDE OF THE DESIGNATED ZONE.

3. DURING CONSTRUCTION, EXISTING SPRINKLERS SHALL

BE TURNED UP TO MAINTAIN PROTECTION IN

CONSTRUCTION AREA UNTIL NEW SYSTEM IS ACTIVE.

THE SYSTEM WILL BE DRAINED DOWN DURING

CONSTRUCTION AND BE FILLED AND LEFT

OPERATIONAL DURING NON CONSTRUCTION TIMES.

AREAS OUTSIDE OF CONSTRUCTION AREA SHALL

MAINTAIN COVERAGE DURING ALL TIMES OF

OCCUPANCY.

GENERAL NOTES

F E

FEC

F E

C

FEC

FEC

F1

F

F1F1

SD

SD

DH

DH

SD

F

F

F

D H

F1

DHFF1

D H

D H

F1

DH

DH

SD

SD

SD

SD

SD

SD

SD

SD

SDSD

SD

SDSD

SDSDSD

SD

SD

SD

SD

SD

SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

F1

SD

T

TT

R N

P S

1. DEVICES SHOWN AS DARK DASHED LINES SHALL BE

DEMO.

2. EXISTING FIRE ALARM SHALL REMAIN OPERATIONAL

DURING CONSTRUCTION.

3. REMOVE ALL CABLES BACK TO SOURCE.

4. REMOVE ALL CONDUIT, CONDUCTORS, AND JUNCTION

BOXES FOR DEMO DEVICES BACK TO PANEL.

5. IF DEVICE IS INSTALLED IN A WALL INDICATED TO

REMAIN, REMOVE CONDUCTORS FROM DEVICES AND

PROVIDE A BLANK COVER PLATE. CONDUIT AND

JUNCTION BOXES IN THE WALL MAY.

FIRE PROTECTION DEMO NOTES

EaFGGaHHbJJbLLaMNNa H.5Ja F.1 EbMaNb

2.8

3.7

7.3

8.2

9.1

4.5

6.2

5.4

5.7

5.3

4.6

10.2

9.8

8.9

8.3

7.2

7.1

3.6

4.1

4.7

5.1

6.1

6.3

8.0

5.5

7.5

3.1

4.4

4.5

5.4

6.2

F.1GHJKLMMa La Jb Hb Ga

6.7

FOURTH FLOOR KEY PLAN

N

B

A

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

FD201

FIRE ALARM DEMOLITION PLAN - 4TH

FLOOR - OVERALL

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

TLKGF

1/8" = 1'-0"

ELECTRICAL 4TH FLOOR OVERALL FIRE DEMO

# Revision Date

JAIME ABSHIER, PE

MO-2020010419

E

C

FEC

FEC

F1

F

SD

SD

DH

DH

SD

F

F

F

D H

F1

DHFF1DH

DH

SD

SD

SD

SD

SD

SD

SD

SD

SDSD

SD

SD

SD

SD

F1

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

3.7

4.5

6.2

5.4

5.7

5.3

4.6

3.6

4.1

4.7

5.1

6.1

6.3

5.5

3.1

4.4

4.5

5.4

6.2

F.1GHJKLMMa La Jb Hb Ga

6.7

1. DEVICES SHOWN AS DARK DASHED LINES SHALL BE

DEMO.

2. EXISTING FIRE ALARM SHALL REMAIN OPERATIONAL

DURING CONSTRUCTION.

3. REMOVE ALL CABLES BACK TO SOURCE.

4. REMOVE ALL CONDUIT, CONDUCTORS, AND JUNCTION

BOXES FOR DEMO DEVICES BACK TO PANEL.

5. IF DEVICE IS INSTALLED IN A WALL INDICATED TO

REMAIN, REMOVE CONDUCTORS FROM DEVICES AND

PROVIDE A BLANK COVER PLATE. CONDUIT AND

JUNCTION BOXES IN THE WALL MAY.

FIRE PROTECTION DEMO NOTES

FOURTH FLOOR KEY PLAN

AREA A

N

B

A

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

FD202

FIRE ALARM DEMOLITION PLAN - 4TH

FLOOR - AREA A

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

TLKGF

3/16" = 1'-0"

ELECTRICAL 4TH FLOOR AREA A FIRE DEMO PLAN

# Revision Date

E

F1F1 D H

D H

F1

SD

SDSD

SDSDSD

SD

SD

SD

SD

SD

SD

SD SD

SD

SD

SD

SD

SD

SD

SD

SD

T

TT

R N

P S

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

7.3

8.2

9.1

9.8

8.9

8.3

7.2

7.1

8.0

7.5

F.1GHJKLMMa La Hb Ga

1. DEVICES SHOWN AS DARK DASHED LINES SHALL BE

DEMO.

2. EXISTING FIRE ALARM SHALL REMAIN OPERATIONAL

DURING CONSTRUCTION.

3. REMOVE ALL CABLES BACK TO SOURCE.

4. REMOVE ALL CONDUIT, CONDUCTORS, AND JUNCTION

BOXES FOR DEMO DEVICES BACK TO PANEL.

5. IF DEVICE IS INSTALLED IN A WALL INDICATED TO

REMAIN, REMOVE CONDUCTORS FROM DEVICES AND

PROVIDE A BLANK COVER PLATE. CONDUIT AND

JUNCTION BOXES IN THE WALL MAY.

FIRE PROTECTION DEMO NOTES

FOURTH FLOOR KEY PLAN

AREA B

N

B

A

1. FIRE ALARM REMOTE POWER SUPPLY EXISTING TO

REMAIN.

SHEET KEYNOTES#

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

FD203

FIRE ALARM DEMOLITION PLAN - 4TH

FLOOR - AREA B

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

TLKGF

3/16" = 1'-0"

ELECTRICAL 4TH FLOOR AREA B FIRE DEMO PLAN

# Revision Date

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

2.8

3.7

7.3

8.2

9.1

4.5

6.2

5.4

6.7

5.7

5.3

4.6

9.8

8.9

8.3

7.2

7.1

3.6

4.1

4.7

5.1

6.1

6.3

8.0

5.5

7.5

3.1

4.4

CHIRO. EXAM

PT GYM

PROST. CHIEF

PROST. ASST. CHIEF

PROST. REP

STAFF TLT.

FUME RM.

PLASTER

MAINT.

421A

DUST RM.

STOR.

426A

CLEAN LAB

PER. CLNC. MASSAGE

PER. CLNC. GROUP RM.

HSKPG.

PROST. PURCHASING

FITTING/EXAM RM.

FITTING/EXAM RM.

PROST. WAIT.

CHIRO. EXAM

ACUPUNCTURE

ACUPUNCTURE

PT/OT EXAM

PT/OT EXAM

PELVIC

PELVIC

PT/OT EXAM BARIATRIC

PT/OT STOR.

PT TLT.

PROST. STOCK RM.

AO

OT SUPER.

BREAK RM.

STAFF TLT.

REHAB. COOR.

PSA

PT/OT SWAMP

CHIEF PM&R EXAM

WAIT.

OT TRAIN. RM.

OT TLT.

440A

CRASH CART ALCOVE

ELEC.

WC STOR./SHOP

CLEAN LINEN

450A

WOMEN'S TLT

MEN'S TLT

MSA CHECKIN/OUT

EQUIP.

ANTE

FITTING/EXAM RM.

CORR.

C43

CORR.

C44

ELEV. LOBBY / CORR.

ELEV. LOBBY

SOILED DISP

401A

TELE HEALTH

PROST. CHECKIN

405A

ELEC.

CORR.

C41

CORR.

C46

CORR.

C47

CORR.

C45

FP FP

FP

F P

F P

F P

F P

F P

F

P

F P

F

P

F P

F P

F P

F

P

F P

FP FP FP FP

FP FP

FP

FP

FP FP

F P

F P

F P

F P

4 4 4

ZONE 24

ZONE 25

FIRE PROTECTION CONTRACTOR SHALL PROVIDE A

COMPLETE CODE COMPLIANT AUTOMATIC WET PIPE

SYSTEM . ALL AREAS NOTED ARE TO BE CONSIDERED

LIGHT HAZARD WITH A MINIMUM SPRINKLER

DISCHARGE DENSITY OF 0.10 GPM/SQ. FT. FOR THE

MOST HYDRAULICALLY REMOTE 1,500 SQ. FT. AND A

100 GPM HOSE STREAM, UNLESS OTHERWISE NOTED

ON THE DRAWINGS.

FIRE PROTECTION CONTRACTOR SHALL PROVIDE A

COMPLETE CODE COMPLIANT AUTOMATIC WET PIPE

SYSTEM . ALL AREAS NOTED ARE TO BE CONSIDERED

ORDINARY HAZARD GROUP I WITH A MINIMUM

SPRINKLER DISCHARGE DENSITY OF 0.15 GPM/SQ. FT.

FOR THE MOST HYDRAULICALLY REMOTE 1,500 SQ.

FT. AND A 250 GPM HOSE STREAM. SPRINKLER HEAD

SPACING SHALL NOT EXCEED MAXIMUM SPACING

DISTANCES SET FORTH BY NFPA 13.

THERE IS NO GENERAL FIRE PROTECTION WORK

ANTICIPATED IN THIS AREA. NEW FIRE SPRINKLER

WORK WILL BE RECONNECTED TO THE EXISTING

SYSTEM IN THIS AREA AS REQUIRED.

HAZARD CLASSIFICATION LEGEND

NFPA 13

PHASED TRANSITIONAL AREA TO REMAIN ACTIVE FOR

THE DURATION OF CONSTRUCTION. COORDINATE

WITH GC AND OWNER TO ENSURE MINIMAL

DOWNTIME AND DISRUPTION FOR REPLACEMENT OF

SYSTEM. AREA IS TO BE REPLACED WITH A LIGHT

HAZARD SYSTEM. WORK IN THIS AREA TO BE

COMPLETED ON NIGHTS BETWEEN THE HOURS OF

5:00 PM AND 7:00 AM, WEEKENDS, AND HOLIDAYS

ONLY. AREAS ARE TO BE LIGHT HAZARD AS REQUIRED

BY NFPA 13 AND AS NOTED ABOVE BY THE LIGHT

HAZARD DESIGN CRITERIA.

AREAS WITH THIS HATCH ARE TO BE COMPLETED

FIRST AS PART OF PHASE 1. COORDINATE WITH GC

AND OWNER TO ENSURE MINIMAL DOWNTIME AND

DISRUPTION FOR REPLACEMENT OF SYSTEM. AREA IS

TO BE REPLACED WITH A LIGHT HAZARD SYSTEM.

WORK IN THIS AREA TO BE COMPLETED ON NIGHTS

BETWEEN THE HOURS OF 5:00 PM AND 7:00 AM,

WEEKENDS, AND HOLIDAYS ONLY. AREAS ARE TO BE

LIGHT HAZARD AS REQUIRED BY NFPA 13 AND AS

NOTED ABOVE BY THE LIGHT HAZARD DESIGN

CRITERIA.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JAIME ABSHIER, PE

MO-2020010419

FX101

FIRE PROTECTION NEW WORK PLAN -

4TH FLOOR - OVERALL

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

SKJJMA

1/8" = 1'-0"

FIRE PROTECTION 4TH FLOOR OVERALL NEW WORK PLAN

1. DO NOT ROUTE SPRINKLER PIPING ABOVE ELECTRICAL

EQUIPMENT.

2. PROVIDE NEW FIRE SPRINKLER SYSTEM FROM

EXISTING CONTROL VALVE LOCATED IN STAIR.

3. CONNECT TO EXISTING FIRE SPRINKLER SYSTEM IN

AREA OUTSIDE SCOPE OF WORK WHERE INDICATED.

4. COMBINATION STANDPIPE AND BULK SUPPLY MAIN IS

TO REMAIN.

5. SPRINKLERS IN STAIR AREA TO BE REMOVED AND

REPLACED WITH SPRINKLERS IN NEW CEILING.

6. NEW SPRINKLER ZONE BOUNDARY LINE.

SHEET KEYNOTES#

1. REFER TO DESIGN NARRATIVE FOR CLARIFICATIONS

OR ADDITIONAL INFORMATION.

2. PROJECT PHASING TO BE COORDINATED WITH THE

GENERAL CONTRACTOR. PRELIMINARY PHASING PLANS

ARE INDICATED ON SHEET GI110.

3. ALL FIRE SPRINKLER MAINS OUTSIDE THE SCOPE OF

WORK ARE EXISTING TO REMAIN. RECONNECT

EXISTING SPRINKLER MAINS TO NEW WORK AS

NECESSARY TO PROVIDE CONTINUOUS PROTECTION IN

ALL OCCUPIED AREAS.

4. CURRENT SPRINKLER ZONE BOUNDARY LINE. ALL

PIPING SUPPLY TO OCCUPIED AREAS ARE TO BE

MAINTAINED DURING CONSTRUCTION AND NO

SPRINKLERS IN OCCUPIED AREAS WILL BE WITHOUT

SERVICE.

5. EAST ZONE 24 TO BECOME SOUTH ZONE 24 AND WILL

BE MAINTAINED BASED ON THE SMOKE COMPARTMENT

SEPARATION. SPRINKLER SYSTEM WILL NOT PROTECT

AREAS OUTSIDE OF THE DESIGNATED ZONE.

6. WEST ZONE 25 TO BECOME NORTH ZONE 2 AND WILL

BE MAINTAINED BASED ON THE SMOKE COMPARTMENT

SEPARATION. SPRINKLER SYSTEM WILL NOT PROTECT

AREAS OUTSIDE OF THE DESIGNATED ZONE.

7. DURING CONSTRUCTION, EXISTING SPRINKLERS SHALL

BE MODIFIED TO MAINTAIN PROTECTION IN

CONSTRUCTION AREAS UNTIL NEW SYSTEM IS ACTIVE.

THE SYSTEM WILL BE DRAINED DOWN DURING

CONSTRUCTION AND BE FILLED AND LEFT

OPERATIONAL DURING NON CONSTRUCTION TIMES.

GENERAL NOTES

EXISTING FEED MAIN

EXISTING COMBINATION STANDPIPE RISER

TEST VALVE

SIGHT GLASS

EXISTING

SECTIONAL

DRAIN VALVE

EXISTING WATERFLOW SWITCH

EXISTING PRESSURE GAUGE

EXISTING INDICATING TYPE FLOOR CONTROL

VALVE WITH SUPERVISORY SWITCH

TO

SYSTEM

TO DRAIN

CONNECT NEW FIRE SPRINKLER

PIPE TO EXISTING FLOOR

CONTROL ARRANGEMENT

EQ EQ

EQ EQ

EQ EQ

36" 12"

36" 12"

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

24" X 48"

CEILING TILE

12" X 48"

CEILING TILE

12" X 12" / 24" X 24"

CEILING TILE

12" X 48"

CEILING TILE

24" X 48"

CEILING TILE

NOTE:

INDICATES CENTERLINE OF SPRINKLER HEAD

TYPICAL SPRINKLER BRANCH

LINE WITH ONE (1) INCH

OUTLET TEES

ONE (1) INCH RISER NIPPLE

LENGTH AS REQUIRED

1" X 1/2" REDUCING

COUPLING

UPRIGHT SPRINKLER HEAD

BRANCH LINE

1" NIPPLE

1" ELBOW

CORRUGATED STAINLESS STEEL HOSE WITH

STAINLESS STEEL BRAID - MINIMUM 1" I.D.

ADJUSTABLE HUB

CLIP TO CEILING GRID SYSTEMMOUNTING BRACKET

CEILING TILE SPRINKLER HEAD

NOTE:

ALL HEADS ON WET SYSTEM UTILIZE FLEXIBLE ASSEMBLY WHERE

POSSIBLE WHEN CLEARANCES ARE TIGHT - FINISH DROPS ARE HARD

PIPED.

SMOOTH BORE CORROSION

RESISTANT OUTLET GIVING

FLOW EQUIVALENT TO ONE

SPRINKLER.

45° ELL

TEST VALVE IN READILY

ACCESSIBLE LOCATION

FROM END OF

REMOTE BRANCH LINE

SEAL OPENING

WATER TIGHT

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

JAIME ABSHIER, PE

MO-2020010419

FX501

FIRE PROTECTION - DETAILS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

SKJJMA

NONE

SPRINKLER CONTROL VALVE

NONE

SPRINKLER HEAD LOCATION

NONE

UPRIGHT SPRINKLER HEAD

NONE

FLEXIBLE SPRINKLER DROP

NONE

INSPECTION TEST

FIRE ALARM SYMBOLS AND LEGEND

EXISTING / DEMOLITION

EXISTING EQUIPMENT / RACEWAYS TO REMAIN

EXISTING EQUIPMENT / RACEWAYS TO BE REMOVED

NEW EQUIPMENT / RACEWAYS

EXISTING TO REMAIN

EXISTING TO BE REMOVED

NEW EQUIPMENT, LIGHTING FIXTURE OR DEVICE

E-6

P

A

E-6

GENERAL ELECTRICAL SYMBOLSRECESSED SURFACE

DISCONNECT SWITCH, 30 AMP MINIMUM UNLESS NOTED

OTHERWISE

FREE STANDING SWITCHBOARD, MOTOR CONTROL

CENTER OR DISTRIBUTION BOARD

A-1,3,5

RACEWAYS AND WIRINGFLOOR WALL CEILING

CONDUIT CONCEALED IN CEILING OR WALL SPACE

FA

EEE

X33

+4'-6"

MH=4'-6"

A-1 A-1A-1

(MS-01) (MS-01) (MS-01)

<RA-1> <RA-1> <RA-1>

FIRE TREATED PLYWOOD BACKBOARD 3/4"X96" HIGH X

LENGTH AS INDICATED

ELECTRICAL EQUIPMENT DESIGNATION DESIGNED "EQ01"

REFERENCE TO NOTE "1" ON SAME SHEET

LIGHTING FIXTURE DESIGNATION

FA = FIXTURE TYPE

MECHANICAL EQUIPMENT DESIGNATION "P-1" INDICATED

EQUIPMENT NAME OR NUMBER

MOUNTING HEIGHT FROM FINISHED FLOOR TO

CENTERLINE OF OUTLET OR EQUIPMENT

MOUNTING HEIGHT FROM FINISHED FLOOR TO BOTTOM

OF OUTLET OR EQUIPMENT

DETAIL REFERENCE NUMBER "1" ON DRAWING "E-6"

SECTION OR ELEVATION REFERENCE LETTER "A" ON

DRAWING "E-6"

INDICATES HOMERUN WITH THREE CIRCUITS AND A

SEPARATE NEUTRALS

CONDUIT RUN EXPOSED

CONDUIT RUN UNDERGROUND OR CONCEALED IN FLOOR

SPACE

EXISTING CONDUIT TO REMAIN

CONDUIT RISING UP FROM RUN

CONDUIT DROPPING DOWN FROM RUN

HOMERUN TO PANELBOARD, CABINET OR TERMINAL

BACKBOARD AS INDICATED

HOMERUN TO SWITCHBOARD OR MCC AS INDICATED.

REFER TO SINGLE LINE DIAGRAM FOR CONDUIT AND WIRE

SIZES

HOMERUN TO PANEL VIA INDICATED LIGHTING CONTROL

RELAY CABINET. REFER TO INDICATED RELAY CABINET

SCHEDULE FOR ADDITIONAL INFORMATION AND

CONTROL REQUIREMENTS

FUSED DISCONNECT SWITCH, 30 AMP MINIMUM UNLESS

NOTED OTHERWISE

COMBINATION DISCONNECT SWITCH MOTOR STARTED

MOTOR, 5 HP INDICATED

TRANSFORMER

RELAY OR EQUIPMENT CABINET AS INDICATED ON PLAN

LIGHTING OR POWER PANEL BOARD

FIRE ALARM SYSTEM

FACP

RNPS

FIRE ALARM CONTROL PANEL

REMOTE NOTIFICATION POWER SUPPLY

FATC FIRE ALARM TERMINAL CABINET

EOL END OF LINE RESISTOR

RA REMOTE ANNUNCIATOR

SD SMOKE DAMPER

MD MAGNETIC DOOR HOLDER

AM ADDRESSABLE MODULE

RM RELAY MODULE

WFS WATER FLOW SWITCH

PIV POST INDICATOR VALVE

VTS VALVE TAMPER SWITCH

H

H

HEAT DETECTOR

HEAT DETECTOR SUBSCRIPT INDICATES:

X = C - ABOVE CEILING

X = F - BELOW FLOOR

X

S

S

SMOKE DETECTOR

SMOKE DETECTOR SUBSCRIPT INDICATES:

X = C - ABOVE CEILING

X = F - BELOW FLOOR

X = D - DUCT

X

MANUAL PULL STATION

WALL CEILING

T

F

F

F

F

F

F DARK TRIANGLE - SPEAKER

HOLLOW TRIANGLE - HORN

HOLLOW CIRCLE - BELL

WALL VISIBLE ONLY

VISIBLE WITH AUDIBLE

REMOTE ALARM INDICATOR /

TEST SWITCH

F

1. REFER TO SPECIFICATIONS SECTION 283111 FOR ADDITIONAL

INFORMATION PERTAINING TO THE FIRE ALARM SYSTEM.

2. SIGNALING LINE CIRCUITS SHALL BE ROUTED IN A CLASS [A] [B]

[X]CONFIGURATION.

3. NOTIFICATION APPLIANCE CIRCUITS SHALL BE ROUTED IN A

CLASS [A] [B] [X] CONFIGURATION.

4. FIRE ALARM CIRCUITS SHALL BE ROUTED IN CONDUIT WHERE

INACCESSIBLE. WHERE ROUTED ABOVE ACCESSIBLE CEILINGS,

FIRE ALARM CIRCUITS SHALL CONSIST OF [PLENUM RATED CABLE

SUPPORTED EVERY 4'-0"][WIRING WITHIN CONDUIT] BETWEEN

DEVICES.

5. WALL MOUNTED NOTIFICATION DEVICES SHALL BE MOUNTED

WITH THE TOP OF THE DEVICE +90" A.F.F. OR 6" BELOW THE

CEILING, WHICHEVER IS LOWER.

6. FOR VISUAL DEVICES, PROVIDE SELECTABLE RANGE: 15CD TO

115CD FOR DEVICES 115CD OR LOWER.

MNS - MASS NOTIFICATION SYSTEM

P - PENDENT

RI - REMOTE INDICATOR

#W - SPEAKER WATTAGE SETTING

#Cd - CANDELA RATTING

C - CEILING

FIRE ALARM - ABBREVIATIONS

FIRE ALARM GENERAL NOTES

1. MAKE ALL INSTALLATIONS IN ACCORDANCE WITH THE AMERICANS WITH

DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG).

2. MOUNTING HEIGHTS INDICATED WITHIN PLANS AND SCHEDULES ARE

DIMENSIONED TO THE CENTER LINE OF THE DEVICE, EQUIPMENT,

LUMINAIRE, ETC. UNLESS OTHERWISE NOTED.

3. COORDINATE EXACT EQUIPMENT LOCATIONS WITH OTHER TRADES.

EQUIPMENT LOCATIONS SHOWN ON ELECTRICAL PLANS ARE

DIAGRAMMATICAL ONLY AND MIGHT NOT BE EXACT.

4. CIRCUIT IDENTIFICATION NUMBERS BESIDE ELECTRICAL DEVICES AND

CONNECTION POINTS ON PLANS CORRESPOND TO AN OVERCURRENT

DEVICE IN THE DESIGNATED PANELBOARD. NOTE ALL CIRCUIT NUMBER

CHANGES MADE IN THE FIELD AT EACH ELECTRICAL DEVICE AND

CONNECTION POINT. ALSO CORRECT THE DIRECTORIES AND DEVICE

MARKINGS AT PANELBOARDS, SWITCHBOARDS AND SWITCHGEAR TO

ACCURATELY REFLECT THE AS-BUILT CONDITIONS.

5. INSTALL EMERGENCY AND EXIT LUMINAIRE WIRING IN A SEPARATE

RACEWAY FROM THAT OF ANY NORMAL POWER DEVICE.

6. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILINGS, AND IN

FLOOR SLABS, ETC. UNLESS OTHERWISE INDICATED ON THE PLANS OR IN

THE SPECIFICATIONS. CONDUIT ROUTED IN MECHANICAL ROOMS,

ELECTRICAL ROOMS, AND STORAGE ROOMS WITHOUT CEILINGS MAY BE

ROUTED EXPOSED.

7. COORDINATE VERTICAL CONDUIT ROUTING TO WALL MOUNTED DEVICES

TO ENSURE DEVICES LOCATED WITHIN AN 18-INCH HORIZONTAL

DIMENSION WILL BE CENTER-ALIGNED VERTICALLY.

8. CONCEAL ELECTRICAL CONNECTIONS FOR ELECTRIC WATER COOLERS

(EWC) BEHIND WATER COOLER ACCESS PLATE OR DIRECTLY BELOW AND

CENTERED ON WALL.

9. FIELD COORDINATE ALL ELECTRICAL AND TELECOMMUNICATIONS

EQUIPMENT MOUNTING LOCATIONS TO AVOID ENCROACHMENT OF

OPERATION AND ACCESS TO EQUIPMENT FROM OTHER TRADES.

COORDINATE THE APPROPRIATE MOUNTING LOCATION WITH THE

AFFECTED DISCIPLINES WHEN EQUIPMENT IS SPECIFIED TO BE MOUNTED

ONTO THE SURFACE OF ANOTHER DISCIPLINE'S EQUIPMENT.

10. REPAIR ALL OPENINGS MADE IN EXISTING WALLS, PARTITIONS, ETC TO

ACCOMMODATE WORK OF THIS DISCIPLINE TO MATCH THE SURROUNDING

CONDITIONS, USING WORKERS QUALIFIED IN THE APPROPRIATE TRADE.

APPROPRIATELY GROUT OR SEAL ALL CONDUITS THROUGH WALLS.

11. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND

FLOORS MUST HAVE BEEN TESTED AND CERTIFIED AS A SYSTEM PER

ASTM E814 STANDARDS FOR FIRE TESTS OF THROUGH-PENETRATION

FIRESTOPS.

12. INSTALL A PERMANENT DIRECTORY ACCORDING TO THE NATIONAL

ELECTRICAL CODE, ARTICLE 230 AT EACH SERVICE ENTRANCE AND

POWER SOURCE.

13. PERFORM ALL WELDING ACCORDING TO AMERICAN WELDING SOCIETY

STANDARDS. FURNISH CERTIFICATES QUALIFYING EACH WELDER TO THE

ARCHITECT OR ENGINEER PRIOR TO START OF WORK. THE ARCHITECT OR

ENGINEER RESERVES THE RIGHT TO REQUIRE QUALIFYING

DEMONSTRATION, AT NO ADDITIONAL EXPENSE, OF ANY WELDERS

ASSIGNED TO THE JOB.

14. REPLACE OR REINSTALL ALL PORTIONS OF THE BUILDING (CEILING TILES,

WALLS, ETC) REMOVED TO ACCOMMODATE THE INSTALLATION OF ANY

ELECTRICAL DEVICE, EQUIPMENT, ETC., USING WORKERS QUALIFIED IN

THE APPROPRIATE TRADE.

15. COORDINATE LUMINAIRE LOCATIONS SUCH THAT LUMINAIRES RUN

PARALLEL TO THE FACE OF THE EQUIPMENT AND OVER AISLES BETWEEN

EQUIPMENT IN ALL MECHANICAL AND ELECTRICAL EQUIPMENT AREAS.

INSTALL AT PROPER LOCATIONS AND HEIGHTS TO PROPERLY ILLUMINATE

ALL GAGES, PANELS, ELECTRICAL EQUIPMENT, CONTROLS, VALVES, ETC.

CHAIN HANGING, STEM HANGING, CHANNEL HANGING, ETC. ARE

ACCEPTABLE METHODS.

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

FA000

FIRE ALARM SYMBOLS AND

ABBREVIATIONS

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

TLKGF

# Revision Date JAIME ABSHIER, PE, MO-2020010419

R E

F

F E

C

F E

C

F E

C

F E

C

F E

C

FEC

FEC

F E

C

FEC

FEC

S

S

S S S

S

S

S

S

S

S S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

S

S

F

F

F

R N

P S

S

S

FM

S D

S D

S D

F R F R

FR

FR

F R

FR

S D

S D

S D

S D

S D

S D

S D

S

DS

D

S D

S D

S D

S D

S D

EaFGGaHHbJJbKLLaMNNa H.5Ja F.1 EbMaNb

2.8

3.7

7.3

8.2

9.1

4.5

6.2

5.4

5.7

5.3

4.6

10.2

9.8

8.9

8.3

7.2

7.1

3.6

4.1

4.7

5.1

6.1

6.3

8.0

5.5

7.5

3.1

4.4

FOURTH FLOOR KEY PLAN

N

B

A

1. CROSS HATCH AREA IS NIGHTS AND WEEK END WORK.

REFER TO ARCHITECT DRAWINGS FOR ADDITIONAL

INFORMATION ON PHASING.

2. DARK DASH LINE SHALL BE NEW FIRE ALARM ZONE

BREAK.

SHEET KEYNOTES#

A

2 3 4 5 6

B

C

D

1 2 3 4 5 6

A

B

C

D

VA FORM 08-6231

o n e e ig e fo o t o n e q u a rt e r i n c e fo o t th re e e ig h th s in c e fo o t o n e h a lf in c e fo o t th re e q u a rt e fo o t o n e in c e fo o t o n e a n d o n e h a lf in c h e e fo o t th re e in c h e e fo o t

CONSULTANTS: ARCHITECT/ENGINEERS:

Drawing Title

Office of Construction and Facilities ManagementApproved: Project Director

Project Title

Location

Date Checked Drawn

Dwg.

Drawing Number

Building Number

Project Number

600 EAST 7TH STEET

SIOUX FALLS, SOUTH DAKOTA 57103

605.274.2893

6 SOUTH OLD ORCHARD

ST. LOUIS, MISSOURI 63119

800.404.7677

330 N MEAD

WICHITA, KANSAS 67202

316.262.2500

FA100

FIRE ALARM FLOOR PLAN - 4TH

FLOOR - OVERALL

RELOCATE PHYSICAL

MEDICINE & REHAB. TO THE

4TH FLOOR

800 HOSPITAL DRIVE COLUMBIA, MO 65201

02-15-2023

589A4-22-100

BID DOCUMENTS

TLKGF

1/8" = 1'-0"

FIRE ALARM 4TH FLOOR OVERALL NEW WORK

# Revision Date JAIME ABSHIER, PE, MO-2020010419

Sheets
AI603 - SIGNAGE PLAN - 4TH FLOOR - AREA B

File details come from the government source that posted it. Updated .