Contract Att09 - CDRL D001 - WTMD - CEIA Decommission Checklist_05.19.2025.xlsx

XLSX spreadsheet 47 KB Posted

Attached to
Screening Equipment Deployment Services (SEDS) - Checkpoint (CP)
Solicitation number
TSA25-04-0506
Issued by

About this file

This document is a detailed Decommission Checklist for a CEIA Walkthrough Metal Detector (WTMD) used in Transportation Security Administration (TSA) screening operations. The comprehensive checklist covers multiple evaluation criteria across several key areas, including electrical power availability, inventory verification, system component assessment, operational testing, unit condition inspection, visual documentation requirements, and packaging preparation. The checklist mandates thorough documentation of the metal detector's condition, requiring inspections of exterior and interior damage, functional testing of detection lights and audio, photographic evidence of the unit from multiple angles, and verification by multiple parties including the performing technician, system integrator, and a federal employee witness.

The checklist is associated with the TSA's Screening Equipment Deployment Services (SEDS) - Checkpoint solicitation, a special notice draft providing industry advance information about an upcoming procurement. The TSA anticipates releasing the full Request for Proposal (RFP) in Q1 or Q2 of FY26, with interested parties encouraged to submit questions and feedback to specified TSA contacts Lindsay Alexander and Heather Karle. The document appears to be part of a systematic process for decommissioning and tracking screening equipment, ensuring careful inventory management and condition documentation for metal detectors used in airport security checkpoints.

View the file

Other files

File Type Posted
Contract Att14 - CP SEDS Pricing Sheet_07.31.2025.xlsx XLSX spreadsheet
Contract Att04 - CDRL D001 - BLS - CEIA EMA-MS Decommission Checklist_05.21.2025.xlsx XLSX spreadsheet
Contract Att08 - CDRL D001 - ETD - QSB220 De-Install - Install Checklist_05.19.2025.xlsx XLSX spreadsheet
Contract Att05 - CDRL D001 - BLS - Smiths Responder Decomm Checklist_05.21.2025.xlsx XLSX spreadsheet
Contract Att01 - CDRL D001 - AIT-1 and AIT-2 - Leidos Decommission Checklist_05.21.2025.xlsx XLSX spreadsheet
Questions on Draft PWS SEDS CP.xlsx XLSX spreadsheet
Contract Att03- CDRL D001 - AT Decommission Checklist_05.19.2025.xlsx XLSX spreadsheet
Contract Att06 - CDRL D001 - CT De-install Decommission Checklist_05.28.2025.xlsx XLSX spreadsheet
Contract Att13 - CDRL B006 - Closeout Report_05.12.2025.xlsx XLSX spreadsheet
Contract Att10 - CDRL B002 - PSP Site Survey_06.04.2025.xlsx XLSX spreadsheet
Contract Att12 - CDRL B001- Daily Site Report_05.12.2025.xlsx XLSX spreadsheet
CP SEDS II IDIQ SOW_08.19.2025.docx DOCX document
Contract Att11 - CDRL A004 - Weekly Status Report (WSR)_02.13.2025.xlsx XLSX spreadsheet
Contract Att02 - CDRLD001 - AIT - RS Decommission Checklist _08.18.2025.xlsx XLSX spreadsheet
Contract Att07 - CDRL D001 - ETD - 500DT Install - De-Installation Checklist_05.19.2025.xlsx XLSX spreadsheet
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1 Decommission Checklist For the CEIA Walkthrough Metal Detector (WTMD)

WTMD S/N: TSA Bar Code Number:

Airport Code: Terminal/Checkpoint/Lane: Date of Test:

The comments/concerns section may be used to provide further detail concerning unit quality, quantity, or general notes on unit/part condition
SectionEvaluation CriteriaYesNoComments/Concerns
Electrical power available on-site to initiate the decommission process?
InventoryCEIA 02PN20 WTMD System?
CEIA 02PN20EZ WTMD System?
Power Supply - Security Plug Adapter?

(Confirm power supply has a twist lock plug) Power Supply - Security Plug Adapter?

(Confirm power supply has a three prong plug)

Unit Keys?
Panel A (Transmitter)/Panel B (Receiver)?
720mm Crosspiece?
TX/RX Antennas with Power Supply Module?
Single Control Unit with Connection Cables?
Master/Slave Control Unit with Connection Cables?
Hardware Package (4 Panels/4 Control Screws)?
Shipping Box/Package?
TestingDetection Lights are Operational?
Detection Audio is Operational?
Unit ConditionDoes the unit have any Exterior Damage?

(i.e. broken pieces, dents, paint chipping, locally added stickers) Does the unit have Interior Damage?

(i.e. broken pieces, dust, locally added stickers)

Visible hardware is tightened and secured?
Panels are flush and fit satisfactory?

Visual Verification Take a photo of the unit while OPERATIONAL and document any damage or concerns. (screen included) Take a photo of the FRONT of the unit and document any damage or concerns.

Take a photo of the SIDES of the unit and document any damage or concerns.

Take a photo of the BACK of the unit and document any damage or concerns.

Take a photo of the MASTER ELECTRONIC UNIT on the unit and document any damage or concerns.
Take a photo of the power supply and document any damage or concerns.
Take a photo of the SERIAL NUMBER and BARCODE on the unit and document any damage or concerns.
Unit PackagingTake photo of the unit PACKAGED for shipping and document any damage or concerns.
Is the labeling correct on the packaging?
Subcontractor Contact Information and Verification
Sign and date this Decommission Checklist and leave a copy with the unit.
Performed By:
Printed NameEmail AddressPhone Number
Company NameSignatureDate
System Integrator Section (This section should be filled in by the System Integrator ONLY)
Evaluation CriteriaYesNoComments/Concerns
Has all damage been documented? If NO, please specify in the comments section.
Are there any components missing? If YES, please specify in the comments section.
Is an Operational Test Kit being returned with this unit? If YES, please note it in the comments section.

Systems Integrator Additional Comments

Systems Integrator Contact Information and Verification
Sign and date this Decommission Checklist and leave a copy with the unit prior to packaging.
Reviewed By:
Printed NameEmail AddressPhone Number
Company NameSignatureDate

Federal Employee Comments/Concerns

Federal Employee Verification
As a witness, sign and date this Decommission Checklist to confirm the document was completed on-site.
Confirmed By:
Printed NameSignatureDate

image1.png

File details come from the government source that posted it. Updated .