Contract Att04 - CDRL D001 - BLS - CEIA EMA-MS Decommission Checklist_05.21.2025.xlsx

XLSX spreadsheet 39 KB Posted

Attached to
Screening Equipment Deployment Services (SEDS) - Checkpoint (CP)
Solicitation number
TSA25-04-0506
Issued by

About this file

This document is a Decommission Checklist for a Bottled Liquid Scanner (BLS) used in Transportation Security Administration (TSA) checkpoint screening operations. The detailed checklist provides a comprehensive evaluation process for decommissioning an EMA-MS BLS system, covering multiple critical assessment areas including inventory verification, system testing, unit condition inspection, cleaning requirements, visual documentation, packaging assessment, and multi-party verification.

The checklist requires thorough documentation by three key parties: the initial performing technician, a system integrator, and a federal employee witness. Each section mandates detailed documentation of system condition, operational status, potential damage, and completeness of components. The checklist is specifically designed to ensure systematic and standardized decommissioning of screening equipment, with sections for noting system operational checks, exterior and interior damage, photographic evidence, and packaging integrity. This document appears to be associated with the TSA's Screening Equipment Deployment Services (SEDS) Checkpoint program, which is anticipated to release a full Request for Proposals (RFP) in Q1 or Q2 of FY26.

View the file

Other files

File Type Posted
Contract Att14 - CP SEDS Pricing Sheet_07.31.2025.xlsx XLSX spreadsheet
Contract Att08 - CDRL D001 - ETD - QSB220 De-Install - Install Checklist_05.19.2025.xlsx XLSX spreadsheet
Contract Att05 - CDRL D001 - BLS - Smiths Responder Decomm Checklist_05.21.2025.xlsx XLSX spreadsheet
Contract Att01 - CDRL D001 - AIT-1 and AIT-2 - Leidos Decommission Checklist_05.21.2025.xlsx XLSX spreadsheet
Questions on Draft PWS SEDS CP.xlsx XLSX spreadsheet
Contract Att03- CDRL D001 - AT Decommission Checklist_05.19.2025.xlsx XLSX spreadsheet
Contract Att06 - CDRL D001 - CT De-install Decommission Checklist_05.28.2025.xlsx XLSX spreadsheet
Contract Att13 - CDRL B006 - Closeout Report_05.12.2025.xlsx XLSX spreadsheet
Contract Att10 - CDRL B002 - PSP Site Survey_06.04.2025.xlsx XLSX spreadsheet
Contract Att09 - CDRL D001 - WTMD - CEIA Decommission Checklist_05.19.2025.xlsx XLSX spreadsheet
Contract Att12 - CDRL B001- Daily Site Report_05.12.2025.xlsx XLSX spreadsheet
CP SEDS II IDIQ SOW_08.19.2025.docx DOCX document
Contract Att11 - CDRL A004 - Weekly Status Report (WSR)_02.13.2025.xlsx XLSX spreadsheet
Contract Att02 - CDRLD001 - AIT - RS Decommission Checklist _08.18.2025.xlsx XLSX spreadsheet
Contract Att07 - CDRL D001 - ETD - 500DT Install - De-Installation Checklist_05.19.2025.xlsx XLSX spreadsheet
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Table 1 Decommission Checklist For the CEIA EMA-MS Bottled Liquid Scanner (BLS)

BLS S/N: TSA Bar Code Number:

Airport Code: Terminal/Checkpoint/Lane: Date of Test: Time:

The comments/concerns section may be used to provide further detail concerning unit quality, quantity, or general notes on unit/part condition
SectionEvaluation CriteriaYesNoComments/Concerns
InventoryEMA-MS BLS System?
Power Supply?
"Normal Object" Test Sample with Green Label?

(NO PASS)

"Abnormal Object" Test Sample with Red Label?

(NO PASS)

TestingWhat was the time frame when the system was last used?
Please mark one (1) box.Please check one
(1) box:Past/Current
DayPast 3 DaysPast WeekPast MonthMore than a
monthUnknown
Does the system turn on?
Does the system allow users to Log On?
Did the system pass the System Operational Check (PASS) Successfully?
Did the system pass the System Operational Check (NO

PASS) Successfully?

Unit Condition Does the unit have any Exterior Damage?

(i.e. broken pieces, dents, paint chipping, locally added stickers) Does the unit have Interior Damage?

(i.e. broken pieces, dust, locally added stickers)

CleaningWipe the analysis compartment (AC) clean, using a slightly moist (water only), non-abrasive cloth.
In case of liquid spill in the AC, tilt unit forward and wipe AC with a dry non-abrasive cloth

Visual Verification Take a photo of the unit while OPERATIONAL and document any damage or concerns. (screen included) Take a photo of the FRONT of the unit and document any damage or concerns.

Take a photo of the SIDES of the unit and document any damage or concerns.

Take a photo of the BACK of the unit and document any damage or concerns.

Take a photo of the SERIAL NUMBER and BARCODE on the unit and document any damage or concerns.

Take a photo of the MAKE/MODEL of the unit and document any damage or concerns.

Unit Packaging Take photo of the unit PACKAGED for shipping and document any damage or concerns.

Is there packaging for the BLS responder? Please indicate what type of packaging in the comments (pelican case, cardboard box, etc.).
Is the labeling correct on the packaging?
Subcontractor Contact Information and Verification
Sign and date this Decommission Checklist and leave a copy with the unit.
Performed By:
Printed NameEmail AddressPhone Number
Company NameSignatureDate
System Integrator Section (This section should be filled in by the System Integrator ONLY)
Evaluation CriteriaYesNoComments/Concerns
Has all damage been documented? If NO, please specify in the comments section.
Are there any components missing? If YES, please specify in the comments section.
Is a Verification Kit being returned with this unit? If YES, please note it in the comments section.
Systems Integrator Additional Comments
Systems Integrator Contact Information and Verification
Sign and date this Decommission Checklist and leave a copy with the unit.
Reviewed By:
Printed NameEmail AddressPhone Number
Company NameSignatureDate

Federal Employee Comments/Concerns

Federal Employee Verification
As a witness, sign and date this Decommission Checklist to confirm the document was completed on-site.
Confirmed By:
Printed NameSignatureDate

image1.jpeg