Attachment G - 1362850dwg2of15_LIFE SAFETY.pdf

PDF 388 KB Posted

Attached to
Small Projects MACC MCAS Beaufort Federal contract opportunity
Solicitation number
N4008523R2575
Issued by
Department of the Navy Naval Facilities Engineering Command

View the file

Other files for this federal contract opportunity

Other files attached to Small Projects MACC MCAS Beaufort, newest first.
File Type Posted
AMENDMENT 0008.pdf PDF
23R2575 AMENDMENT 0007.pdf PDF
Amendment 0007 - Attachment E - Price Proposal Form REV 3.docx DOCX document
23R2575 AMENDMENT 0006.pdf PDF
Amendment 0006 - Attachment E - Price Proposal Form REV 2.docx DOCX document
Amendment 0006 - BLDG-P485-1362850-AE531 - MISCELLANEOUS DETAILS_REV3.pdf PDF
Amendment 0005 - Site Visit Sign-In Sheet.pdf PDF
23R2575 AMENDMENT 0005.pdf PDF
Amendment 0005 - Attachment E - Price Proposal Form REV 1.docx DOCX document
N4008523R2575 AMENDMENT 0004.pdf PDF
N4008523R2575 AMENDMENT 0003.pdf PDF
N4008523R2575 AMENDMENT 0002.pdf PDF
N4008523R2575 AMENDMENT 0001.pdf PDF
Attachment I - ASO 5510.14 Installation Access Control Measures.pdf PDF
Attachment H - P485 OSF_SPECIFICATIONS_VOL 2.pdf PDF
Attachment G - 1362850Amend0002dwg_ELECTRICAL.pdf PDF
Attachment G - 1362850dwg5of15_ENV.pdf PDF
Attachment D - PIEE Vendor Access Instructions.pdf PDF
Attachment A - Construction and Design Experience Project Data Sheet.docx DOCX document
Attachment E - Price Proposal Form.docx DOCX document
Attachment G - 1362850dwg15of15_ELEC.pdf PDF
Attachment G - 1362850dwg8of15_STRUCT.pdf PDF
Attachment G - 1362850dwg4of15_CIVIL.pdf PDF
Attachment G - 1362850dwg12of15_FIRE SUPPRESSION.pdf PDF
Attachment G - 1362850dwg11of15_FIRE ALARM.pdf PDF
N4008523R2575.pdf PDF
Attachment H - P485 OSF_SPECIFICATIONS_VOL 1.pdf PDF
Attachment G - 1362850dwg9of15_ARCH.pdf PDF
Attachment G - 1362850dwg6of15_CIVIL.pdf PDF
Attachment G - 1362850dwg3of15_GEOTECHNICAL.pdf PDF
Attachment G - 1362850Amend0001dwg_CIVIL.pdf PDF
Attachment G - 1362850dwg10of15_SIGNAGE.pdf PDF
Attachment G - 1362850dwg14of15_MECH.pdf PDF
Attachment F - SECNAV 5512.pdf PDF
Attachment C - Pre-Proposal Inquiry Form.xlsx XLSX spreadsheet
Attachment B - Past Performance Questionnaire (PPQ).pdf PDF
Attachment G - 1362850dwg1of15_GENERAL.pdf PDF
Attachment G - 1362850dwg7of15_LANDSCAPE.pdf PDF
Attachment G - 1362850dwg13of15_PLUMBING.pdf PDF
Attachment G -1362850Amend0001dwg_ARCHITECTURAL.pdf PDF
Attachment G - 1362850Amend0001dwg_ENVIRONMENTAL.pdf PDF
Show all 41

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

X

Y

X = REQUIRED EGRESS CAPACITY (PERSONS)

Y = PROVIDED EGRESS CAPACITY (PERSONS)

TRAVEL PATH AND DISTANCE

COMMON PATH OF TRAVEL

WALL-MOUNTED KNOX BOX

OCCUPANT LOAD

WALL-MOUNTED EXIT SIGN

TD = XX FT

CP = XX FT

LIFE SAFETY LEGEND

K xx

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

12/17/2021

ENGINEERS + SURVEYORS

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

F

O

P E

R A

TI

O

N A

L S

U P

P O

R T

FA

C

IL

IT

Y (O

S F)

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1362850

DRAWFORM REVISION: 07 AUG 2018

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

CJW / SVR

Approved by J. Scott Roberts, Asset Management Branch Head

& Supervisory Facility Planner, PWD Beaufort, SC via email

EJA

DSN

DSN

12/17/2021

B

IM

- P -4

F

-3

O pe ra tio na l S up po rt F ac ili ty /B

LD

G

P

5_ O

S F

-F P

.r vt

/1

6/

1:

:1

A M

1/8" = 1'-0"

B U

IL

D

IN

G

C O

D E

/L

IF

E S

A F

E T

Y A

N A

L Y

S

IS

A N

D L

E G

E N

D

GC001

APF AHE AJW

12854024

3 129

AREA

WAREHOUSE

OCCUPANCY/USE APPROX.

AREA (SF)

OCCUPANT LOAD

FACTOR

(SF/PERSON)

OCCUPANT

LOAD

(PERSONS)

GROUP S-1/STORAGE

OVERALL TOTAL

9,571 9,571

APPLICABLE CRITERIA

USE GROUP/OCCUPANCY

FIRE PROTECTION SYSTEMS

ROOF COVERINGS AND ROOF DECK ASSEMBLIES

OCCUPANT LOAD

ARRANGEMENT OF MEANS OF EGRESS

CAPACITY AND NUMBER OF MEANS OF EGRESS

ADDITIONAL LIFE SAFETY CRITERIA

LIMITATIONS FOR TYPE IIB CONSTRUCTION

TYPE IIB RESISTANCE RATINGS (IN HOURS) OF STRUCTURAL ELEMENTS

FIRE-RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS OF

TYPE IIB BUILDINGS [IBC TABLE 602]

INTERIOR FIRE RESISTANCE REQUIREMENTS

UFC 1-200-01 DOD BUILDING CODE (CHANGE 1, 1 OCT 2020)

UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES (CHANGE 6, 6 MAY 2021)

UFC 4-440-01 WAREHOUSE AND STORAGE FACILITIES (CHANGE 1, 1 APRIL 2019)

IBC INTERNATIONAL BUILDING CODE, 2018

NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019

NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES, 2019

NFPA 70 NATIONAL ELECTRICAL CODE, 2020

NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE, 2019

NFPA 90A STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2021

NFPA 101 LIFE SAFETY CODE, 2021 (LSC)

ABA ARCHITECTURAL BARRIERS ACT

S-1 (IBC 311.2) / STORAGE (LSC 6.1.13) - ORDINARY HAZARD (LSC 42.1.5)

WET PIPE SPRINKLER SYSTEM

FIRE ALARM SYSTEM

BASED ON LSC TABLE A.7.6:

MEANS OF EGRESS MUST BE ILLUMINATED IN ACCORDANCE WITH LSC 7.8 (LSC 42.2.8.1). ARTIFICIAL LIGHTING IS REQUIRED AT LOCATIONS

AND TIMES NECESSARY TO MAINTAIN ADEQUATE ILLUMINATION (LSC 7.8.1.2.1).

EMERGENCY LIGHTING IS REQUIRED IN NORMALLY OCCUPIED STORAGE OCCUPANCIES (LSC 42.2.9).

MEANS OF EGRESS MUST BE PROVIDED WITH SIGNS IN ACCORDANCE WITH LSC 7.10 (42.2.10). SIGNS MUST HAVE LETTERING ON AN OPAQUE BACKGROUND. INTERNALLY ILLUMINATED SIGNS MUST BE LIGHT EMITTING DIODE (LED) TYPE, ELECTROLUMINESCENCE (LEC), OR COLD CATHODE TYPE. INCANDESCENT FIXTURES ARE NOT PERMITTED. RADIOLUMINOUS EXIT SIGNS ARE NOT PERMITTED.

PORTABLE FIRE EXTINGUISHERS ARE NOT REQUIRED IN STORAGE OCCUPANCIES (LSC 42.3.5).

REQUIRED EGRESS

CAPACITY

AVAILABLE EGRESS

CAPACITY

MEANS OF EGRESS

REQUIRED

MEANS OF EGRESS

PROVIDED

ALLOWABLE HEIGHT

ACTUAL HEIGHT

BUILDING ELEMENT

STRUCTURAL FRAME, INCLUDING COLUMNS, GIRDERS, TRUSSES

STRUCTURAL FRAME SUPPORTING A ROOF ONLY

BEARING WALLS, EXTERIOR

BEARING WALLS, INTERIOR

NON-BEARING WALLS, EXTERIOR

NON-BEARING WALLS, INTERIOR

FLOOR CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS

ROOF CONSTRUCTION, INCLUDING SUPPORTING BEAMS AND JOISTS

REQUIRED

FIRE SEPARATION DISTANCE (FSD)

FSD < 5 FT

5 FT ≤ FSD < 10 FT

FSD ≥ 10 FT

GROUP S-1

ALLOWABLE AREA (SF)

ACTUAL AREA (SF)

LOAD FACTORS (LSC TABLE 7.3.1.2):

WAREHOUSE (MAXIMUM PROBABLE NUMBER OF OCCUPANTS AT ANY TIME)

ROOF COVERING MUST BE A MINIMUM CLASS B AND MUST BE LISTED OR APPROVED (IBC TABLE 1505.1 & UFC 3-600-01 15-1).

ROOF DECK ASSEMBLIES MUST BE FM CLASS I APPROVED OR UL LISTED AS FIRE CLASSIFIED (UFC 3-600-01 15-2.1.1).

FACILITY

OSF

CAPACITY OF MEANS OF EGRESS (LSC TABLE 7.3.3.1):

LEVEL COMPONENTS (WIDTH/PERSON) 0.2 IN/PERSON

STAIRWAYS (WIDTH/PERSON) 0.3 IN/PERSON

NUMBER OF MEANS OF EGRESS (LSC 7.4):

2 FOR AREAS WITH AN OCCUPANT LOAD LESS THAN 500

COMMON PATH OF

TRAVEL (FT)

DEAD-END

CORRIDOR (FT)

OCCUPANCY

GROUP S-1

TYPE IIB

75 FT

1 STORY

28 FT

1 STORY

70,000 12,466

STORAGE - ORDINARY HAZARD

NONE

PROVIDED

EXIT ACCESS

TRAVEL DISTANCE (FT)

REQUIRED/PROVIDED

REQUIRED

PROVIDED

THE DISTANCE BETWEEN THE OSF AND THE CLOSEST BUILDING IS GREATER THAN 60-FT, WHICH PROVIDES A FIRE SEPARATION DISTANCE OF AT LEAST 10-FT FROM THE OSF TO THE IMAGINARY LOT LINE; THEREFORE, THE EXTERIOR WALLS OF THE OSF ARE NOT

REQUIRED TO BE RATED.

INTERIOR FINISH CLASSIFICATION

MINIMUMS BASED ON LSC TABLE A.10.2.2:

EXITS

CLASS C

EXIT ACCESS

CORRIDORS

OTHER

CLASS C

OCCUPANCY

CLASS C

STORAGE

REQUIRED/PROVIDED

REQUIRED

CLASS C CLASS CCLASS CPROVIDED

FIRE DEPARTMENT ACCESS AND FIRE HYDRANTS

THE OSF MUST BE PROVIDED WITH SUITABLE ALL-WEATHER GROUND ACCESS ON A MINIMUM OF TWO SIDES OF THE PERIMETER OF THE STRUCTURE (UFC 3-600-01 9-1.2). ALL-WEATHER GROUND ACCESS MUST BE PAVED, START FROM THE ROAD, AND TERMINATE NO FARTHER THAN 33-FT FROM AN EXTERIOR DOOR ACCESSIBLE FOR FIRE DEPARTMENT INGRESS (UFC 3-600-01 9-1.1).

DIMENSION OF FIRE LANES AND TURNAROUNDS MUST COMPLY WITH THE REQUIREMENTS OF NFPA 1 (UFC 3-600-01 9-1.3).

ALL PARTS OF THE OSF EXTERIOR MUST BE WITHIN 350-FT OF A FIRE HYDRANT (UFC 3-600-01 9-1.3).

FIRE HYDRANTS MUST BE SPACED ALONG THE SIDE OF THE OSF WITH FIRE DEPARTMENT ACCESS AT 300-FT INTERVALS (UFC 3-600-01 9-3.5.8.4.B).

AT LEAST ONE FIRE HYDRANT MUST BE LOCATED WITHIN 150-FT OF THE FIRE DEPARTMENT CONNECTION (UFC 3-600-01 9-3.5.8.4.A).

SEISMIC DESIGN

SEISMIC DESIGN CATEGORY D

0 20' 40'

IP

L

60-FT

FH

FH

P-485

HANGAR

FH

RISER

FACP

FDC

PIV

CODE COMPLIANCE SITE PLANA1

FIRE

DEPARTMENT

VEHICLE ACCESS

HL - 176-FT

SCALE: 1" = 20'-0"GC002

NOTES:

DE - DEAD-END DISTANCE FOR FIRE ACCESS LANE

FACP - FIRE ALARM CONTROL PANEL

FDC - FIRE DEPARTMENT CONNECTION

FH - FIRE HYDRANT

HL - HOSE LAY DISTANCE

IPL- IMAGINARY PROPERTY LINE

PIV - POST INDICATOR VALVE

RISER - SPRINKLER RISER

W - WIDTH OF FIRE ACCESS LANE

60-FT - MINIMUM 60-FT YARD FOR UNLIMITED AREA HANGAR

W - 24.5-FT

81-FT

W - 51.5-FT

DE - 101-FT

10'

K

K

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

12/17/2021

ENGINEERS + SURVEYORS

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

F

O

P E

R A

TI

O

N A

L S

U P

P O

R T

FA

C

IL

IT

Y (O

S F)

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1362850

DRAWFORM REVISION: 07 AUG 2018

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

CJW / SVR

Approved by J. Scott Roberts, Asset Management Branch Head

& Supervisory Facility Planner, PWD Beaufort, SC via email

EJA

DSN

DSN

12/17/2021

B

IM

- P -4

F

-3

O pe ra tio na l S up po rt F ac ili ty /B

LD

G

P

5_ O

S F

-F P

.r vt

/1

6/

1:

:1

A M

1" = 20'-0"

C O

D E

C O

M P

LI

A

N C

E S

IT

E

P

LA

N

GC002

APF AHE AJW

12854025

4 129

FACP

K

K

STORAGE 1

STORAGE 2

' - 6

CP = 31 FT

TD = 62 FT

TD = 82 FT

CP = 44 FT

1 2 3 6

F

E

D

C

B

4 5

Lic. No. 044409

AARON P FREIDC

O M M O

N W

EAL

THOF

V

IR

G

IN

IA

P R O F

E

SSIONAL EN

G

IN

E E R

12/17/2021

A B

KEYPLAN

A B

KEYPLAN

ENGINEERS + SURVEYORS

KEY NOTES 00

0 5'

1/8" = 1'-0" GRAPHIC SCALE

10' 20' 30'

N PLAN

NORTH

1 2 3 4 5

3 4 5

D

C

B

A

SHEET OF

NAVFAC DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

P -4

F

O

P E

R A

TI

O

N A

L S

U P

P O

R T

FA

C

IL

IT

Y (O

S F)

D C

C O

R E

B E

A U

F O

R T

, S C

N O

R F

O

LK

, V A

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D

M

ID

-A T

LA

N

T

IC

M C

A S

B E

A U

F O

R T

FP ENGINEER

CHIEF ENG/ARCH

BRANCH MANAGER

PM/DM

DES DRW CHK

SATISFACTORY TO DATE

ACTIVITY

FOR COMMANDER NAVFAC

APPROVED

A/E INFO

SEAL

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

1362850

DRAWFORM REVISION: 07 AUG 2018

NOTE:

IF THIS DRAWING IS LESS THAN 34" X 22"

IT IS A REDUCED SIZE DRAWING

D

C

B

A

1 2

CJW / SVR

Approved by J. Scott Roberts, Asset Management Branch Head

& Supervisory Facility Planner, PWD Beaufort, SC via email

EJA

DSN

DSN

12/17/2021

B

IM

- P -4

F

-3

O pe ra tio na l S up po rt F ac ili ty /B

LD

G

P

5_ O

S F

-F P

.r vt

/1

6/

1:

:1

A M

1/8" = 1'-0"

LI

F

E S

A F

E T

Y F

LO

O

R P

LA

N

F

IR

S

T F

L O

O R

GC101

APF AHE AJW

12854026

5 129

1/8" = 1'-0" A1

LIFE SAFETY FLOOR PLAN - FIRST FLOOR

1 FOR KNOX BOX INSTALLATION LOCATION, SEE SHEET AE202 FOR

ADDITIONAL DETAILS.

LIFE SAFETY
GC001 - BUILDING CODE/LIFE SAFETY ANALYSIS AND LEGEND
GC002 - CODE COMPLIANCE SITE PLAN
GC101 - LIFE SAFETY FLOOR PLAN - FIRST FLOOR

2022-01-27T07:52:48-0500

2022-01-27T07:53:57-0500

2022-01-27T07:53:58-0500

2022-02-16T13:47:28-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-02-16T13:47:41-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-02-16T13:47:41-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-02-16T13:47:53-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-02-16T13:48:08-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.
2022-02-16T13:48:08-0500
James E. Donahue, R.A.
I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed.

File details come from the government source that posted it. Updated .