Attachment G -1362850Amend0001dwg_ARCHITECTURAL.pdf
PDF 564 KB Posted
- Attached to
- Small Projects MACC MCAS Beaufort Federal contract opportunity
- Solicitation number
- N4008523R2575
View the file
Other files for this federal contract opportunity
Show all 41
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A2
AE471
5095 SF
STORAGE 1
4623 SF
STORAGE 2
AIR BARRIER SURFACE AREAS
ELEMENT
WALLS
SURFACE AREA COMMENT
9,180 SQ FT
NOTE 1: AIR BARRIER QUANTITIES ABOVE ARE FOR REFERENCE AND APPLY TO
INSPECTION ONLY. REFERENCE UFC 3-101-01, 3-6.3.
NOTE 2: THE AIR BARRIER IS THE GROSS AREA OF: SLAB, EXTERIOR PERIMETER
WALLS, AND ROOF SURFACE. (AREAS DO NOT INCLUDE OPENINGS, SUCH AS
WINDOWS AND DOORS).
TOTAL WALL AREA
SLAB 9,668 SQ FT TOTAL FLOOR SLAB
10,690 SQ FT TOTAL ROOF AREA ROOFS
29,538 SQ FT TOTAL SURFACE AREA (EXTERIOR ENVELOPE)
EXTERIOR
INTERIOR
PRECIPITATION
CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
HEAT CONTROL LAYER
PRECIPITATION CONTROL LAYER
CONTINUOUS AIR /
WATER SEAL
VAPOR CONTROL
LAYER
AIR CONTROL LAYER
EXTERIOR INTERIOR
PRECIPITATION
CONTROL LAYER
VAPOR CONTROL
LAYER
HEAT CONTROL
LAYER
PRECIPITATION
CONTROL LAYER
HEAT CONTROL LAYER
AIR CONTROL
LAYER
VAPOR CONTROL
LAYER
CONTINUOUS AIR /
WATER SEAL
CONTINUOUS AIR /
WATER SEAL
AIR CONTROL
LAYER
F
12'-0"
AFF
1'-6"
EXTERIORINTERIOR
VAPOR CONTROL LAYER
AIR CONTROL LAYER
HEAT CONTROL LAYER
PRECIPITATION CONTROL LAYER
HEAT CONTROL LAYER
VAPOR CONTROL LAYER
AIR CONTROL LAYER
HEAT CONTROL LAYER
PRECIPITATION LAYER
TYPEGRAPHIC
BARRIER LAYER LEGEND
AR94753
D
F
A
ETS
ER
I
G E
R
T S
T
OE RID
TIHCRA
C E
T
A
OF L
R E
N W
IC
K
OL I VAREZ
D A
E L
O
A B
KEYPLAN
A B
KEYPLAN
A B
KEYPLAN
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
N PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
F
O
P E
R A
T
IO
N S
S U
P P
O R
T F
A C
IL
IT
Y
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V
IR
G
IN
IA
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1362850
DRAWFORM REVISION: 25 AUG 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
CJW / SVR
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email
DJD
EJA
DSN
12/17/2021
B
IM
- P -4
F
-3
O pe ra tio na l S up po rt F ac ili ty /B
LD
G
-P
5-
0- A
R _R
.rv t
6/ 6/
:5
2:
P M
As indicated
A
IR
B A
R R
IE
R
D
IA
G R
A M
S
AE471
EAD MEC ROD
12854094
1/8" = 1'-0" A2
AIR BARRIER DIAGRAM
1/8" = 1'-0" B2
AIR BARRIER DIAGRAM - FLOOR PLAN
A REFER TO SHEET AE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL
SYMBOLS.
B PROVIDE A CONTIGUOUS AND CONTINUOUS AIR BARRIER ACROSS THE ENTIRE
BUILDING ENVELOPE AND ENSURE AIR BARRIER IS IN FULL CONTACT WITH
CONTINUOUS INSULATION.
C FULLY SEAL ALL SEAMS, GAPS, AND PENETRATIONS IN THE AIR BARRIER.
D THE OPERATION SUPPORT FACILITY (OSF) SPACE ONLY REQUIRES AIR BARRIER
SYSTEM INSPECTION PER UFC 3-101-01, CHAPTER 3, SECTION 3-6.3. THE OSF IS
CLASSIFIED AS A SEMI HEATED, WAREHOUSE FUNCTION.
E PRIMARY EXTERIOR WALL IS A MASS WALL COMPOSED OF AN INSULATED PRECAST
SYSTEM. THE WALL DEPTH IS 12 INCHES (4 INCH PRECAST+ 4 INCH RIGID INSULATION +
4 INCH PRECAST). INSULATED PRECAST WALL SYSTEM IS CONSIDERED A BARRIER OR
FACE-SEALED SYSTEM.
F PROVIDE FLUID-APPLIED MEMBRANE AIR BARRIER/VAPOR RETARDER (072726.A01) AT
EXTERIOR WALLS. APPLY AIR BARRIER TO EXTERIOR FACE OF GLASS-MAT EXTERIOR
SHEATHING. REFER TO SHEET SERIES AE500 FOR EXTERIOR DETAILS.
G PROVIDE HIGH-TEMPERATURE UNDERLAYMENT (076115.V01) AT SLOPED, STANDING
SEAM METAL ROOF TO SERVE AS AN AIR BARRIER. REFER TO SHEET SERIES AE500
FOR EXTERIOR DETAILS.
H WRAP AIR BARRIER INTO DOOR, LOUVER, AND TRANSLUCENT WINDOW OPENINGS.
REFER TO SHEET AE621 FOR EXTERIOR DOOR DETAILS AND SHEET AE622 FOR
TRANSLUCENT WINDOW AND LOUVER DETAILS.
I ALTHOUGH THE DRAWINGS SHOW THE LOCATION OF THE AIR BARRIER SYSTEM
COMPONENTS INCLUDING DETAIL OF JOINTS, INTERSECTIONS, AND PENETRATIONS OF
THE SYSTEM, IT IS THE CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT THE AIR
BARRIER SYSTEM IS INSTALLED IN A CONTINUOUS ENVELOPE.
J PROVIDE POLYETHYLENE SHEETING VAPOR BARRIER (033000.V01) BELOW SLAB.
A1 A1
NOT TO SCALE
D1
BARRIER LAYER DIAGRAM - DOOR JAMB
NOT TO SCALE
B1
BARRIER LAYER DIAGRAM - DOOR HEAD
NOT TO SCALE
A1
BARRIER LAYER DIAGRAM - DOOR HEAD
1 PERIMETER SEAL SYSTEM COMPONENT: "Z"-TYPE LINTEL SEAL WITH 3/4"
BRUSH
B
Y A
M E
N D
M E
N T
6/ 6/
2 2
INTERIOR
EXTERIOR
PRECIPITATION CONTROL LAYER
INSULATED CURTAIN SLATS
PROVIDE PRECIPITATION, HEAT
AND VAPOR/AIR CONTROL
HEAT CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
12'-0"
AFF
INTERIOREXTERIOR
PRECIPITATION
CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
HEAT CONTROL LAYER
PRECIPITATION
CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
HEAT CONTROL LAYER
AIR CONTROL LAYER
AIR CONTROL LAYER
PRECIPITATION
CONTROL LAYER
PRECIPITATION
CONTROL LAYER
CONTINUOUS AIR /
WATER SEAL
CONTINUOUS AIR /
WATER SEAL
16'-3"
TO STEEL BEAM
12'-3"
BO METAL FRAMING
12'-0"
BO PRECAST
12'-5"
BO OVERHEAD HOOD
16'-1/2"
T.O. PRECAST WALL
PRECIPITATION CONTROL LAYER
PRECIPITATION CONTROL LAYER
HEAT CONTROL LAYER
HEAT CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
AIR CONTROL LAYER
VAPOR CONTROL LAYER
HEAT CONTROL LAYER
VAPOR CONTROL LAYER
AIR CONTROL LAYER
HEAT CONTROL LAYER
PRECIPITATION LAYER
TYPEGRAPHIC
BARRIER LAYER LEGEND
AR94753
D
F
A
ETS
ER
I
G E
R
T S
T
OE RID
TIHCRA
C E
T
A
OF L
R E
N W
IC
K
OL I VAREZ
D A
E L
O
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
F
O
P E
R A
T
IO
N S
S U
P P
O R
T F
A C
IL
IT
Y
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V
IR
G
IN
IA
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1362850
DRAWFORM REVISION: 25 AUG 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
CJW / SVR
Approved by J. Scott Roberts, Asset Management Branch Head
& Supervisory Facility Planner, PWD Beaufort, SC via email
DJD
EJA
DSN
12/17/2021
B
IM
- P -4
F
-3
O pe ra tio na l S up po rt F ac ili ty /B
LD
G
-P
5-
0- A
R _R
.rv t
6/ 6/
:5
2:
P M
As indicated
A
IR
B A
R R
IE
R
D
IA
G R
A M
S
AE472
EAD KJF ROD
12854095
A REFER TO SHEET AE001 FOR GENERAL ABBREVIATIONS AND ARCHITECTURAL
SYMBOLS.
B PROVIDE A CONTIGUOUS AND CONTINUOUS AIR BARRIER ACROSS THE ENTIRE
BUILDING ENVELOPE AND ENSURE AIR BARRIER IS IN FULL CONTACT WITH
CONTINUOUS INSULATION.
C FULLY SEAL ALL SEAMS, GAPS, AND PENETRATIONS IN THE AIR BARRIER.
D THE OPERATION SUPPORT FACILITY (OSF) SPACE ONLY REQUIRES AIR BARRIER
SYSTEM INSPECTION PER UFC 3-101-01, CHAPTER 3, SECTION 3-6.3. THE OSF IS
CLASSIFIED AS A SEMI HEATED, WAREHOUSE FUNCTION.
E PRIMARY EXTERIOR WALL IS A MASS WALL COMPOSED OF AN INSULATED PRECAST
SYSTEM. THE WALL DEPTH IS 12 INCHES (4 INCH PRECAST+ 4 INCH RIGID INSULATION +
4 INCH PRECAST). INSULATED PRECAST WALL SYSTEM IS CONSIDERED A BARRIER OR
FACE-SEALED SYSTEM.
F PROVIDE FLUID-APPLIED MEMBRANE AIR BARRIER/VAPOR RETARDER (072726.A01) AT
EXTERIOR WALLS. APPLY AIR BARRIER TO EXTERIOR FACE OF GLASS-MAT EXTERIOR
SHEATHING. REFER TO SHEET SERIES AE500 FOR EXTERIOR DETAILS.
G PROVIDE HIGH-TEMPERATURE UNDERLAYMENT (076115.V01) AT SLOPED, STANDING
SEAM METAL ROOF TO SERVE AS AN AIR BARRIER. REFER TO SHEET SERIES AE500
FOR EXTERIOR DETAILS.
H WRAP AIR BARRIER INTO DOOR, LOUVER, AND TRANSLUCENT WINDOW OPENINGS.
REFER TO SHEET AE621 FOR EXTERIOR DOOR DETAILS AND SHEET AE622 FOR
TRANSLUCENT WINDOW AND LOUVER DETAILS.
I ALTHOUGH THE DRAWINGS SHOW THE LOCATION OF THE AIR BARRIER SYSTEM
COMPONENTS INCLUDING DETAIL OF JOINTS, INTERSECTIONS, AND PENETRATIONS OF
THE SYSTEM, IT IS THE CONTRACTOR'S RESPONSIBILITY TO ASSURE THAT THE AIR
BARRIER SYSTEM IS INSTALLED IN A CONTINUOUS ENVELOPE.
J PROVIDE POLYETHYLENE SHEETING VAPOR BARRIER (033000.V01) BELOW SLAB.
NOT TO SCALE
C1
BARRIER LAYER DIAGRAM - DOOR JAMB
NOT TO SCALE
A1
BARRIER LAYER DIAGRAM - LOUVER
1 OVERHEAD COILING DOOR
2 INSULATED MECHANICAL DUCT WORK
3 PERIMETER SEAL SYSTEM COMPONENT: WEATHER SEAL AND FOAM STRIP.
NOT TO SCALE
A2
BARRIER LAYER DIAGRAM - SECTION DETAIL
B
Y A
M E
N D
M E
N T
6/ 6/
2 2
| BLDG-P485-1362850-AE471-AIR BARRIER DIAGRAMS |
| BLDG-P485-1362850-AE472-AIR BARRIER DIAGRAMS |
| 2022-06-07T18:29:14-0400 | |
| Orlando | |
| Renwick Daelo | |
| I am signing to certify the authenticity of this document. |
| 2022-06-07T18:29:31-0400 | |
| Orlando | |
| Renwick Daelo | |
| I am signing to certify the authenticity of this document. |
| 2022-12-22T09:38:26-0500 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-12-22T09:39:12-0500 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-12-22T09:39:19-0500 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
| 2022-12-22T09:39:38-0500 | |
| Norfolk, VA | |
| James E. Donahue, R.A. | |
| I, James E. Donahue, R.A., am signing this document to confirm that it has been reviewed. |
File details come from the government source that posted it. Updated .