Attachment 5 Seed Proj FXSB 21-1058 SOW SPECS DRAWINGS.pdf

PDF 6 MB Posted

Attached to
JBER MACC Federal contract opportunity
Solicitation number
FA500021R0023
Issued by
Department of the Air Force Pacific Air Forces

About this file

This scope of work document outlines the renovation of two restrooms and conversion of a storage closet into an additional restroom at Building 13373 on Joint Base Elmendorf-Richardson in Alaska. The work includes demolishing existing fixtures and finishes, installing new plumbing, fixtures, partitions, ceilings, lighting, and doors. Requirements include pressure jet cleaning and camera inspection of sewer lines, coordinating with the base for access and utility clearances, using fiberglass reinforced plastic and commercial grade materials, and complying with environmental and safety standards. The related solicitation is for an indefinite delivery/indefinite quantity multiple award construction contract through the Department of the Air Force Pacific Air Forces to complete repair, alteration, and construction projects on Joint Base Elmendorf-Richardson.

View the file

Other files for this federal contract opportunity

Other files attached to JBER MACC, newest first.
File Type Posted
Attachment 29 QA CAO 7 Jul 21.xlsx XLSX spreadsheet
Solicitation Amendment FA500021R00230005 SF 30.pdf PDF
Solicitation Amendment FA500021R00230004 SF 30.pdf PDF
Attachment 28 SUPPLEMENTAL HAZMAT SPECS Seed Proj 20-5254.pdf PDF
Attachment 4 Seed Project FXSB 20-5254 Price Schedule.pdf PDF
Attachment 6 Seed Project FXSB 21-1058 Price Schedule.pdf PDF
Attachment 27 AF Form 66 Seed Proj FXSB 21-1058.pdf PDF
Attachment 29 QA CAO 24 Jun 21.xlsx XLSX spreadsheet
Attachment 2 MACC SOW(CAO 25 June 21).pdf PDF
Attachment 5 Seed Proj FXSB 21-1058 SOW SPECS DRAWINGS.pdf PDF
Attachment 24 FOPR-Seed Project FXSB 21-1058.pdf PDF
Attachment 25 Seed Proj FXSB 20-5254 EXHIBITS 09-JUN-2021.pdf PDF
Attachment 26 AF Form 66 Seed Proj FXSB 20-5254.pdf PDF
Attachment 17 Teaming consent 20201208.pdf PDF
Attachment 23 FOPR-Seed Project FXSB 20-5254.pdf PDF
Solicitation Amendment FA500021R00230001 SF 30.pdf PDF
Solicitation Amendment FA500021R00230003 SF 30.pdf PDF
Solicitation Amendment - FA500021R00230002.pdf PDF
Solicitation Amendment FA500021R00230002 (Summary of Changes).pdf PDF
Amendment 2 Attachment 1 - Site Visit Sign in Sheets FXSB 20-5254 and 21-1058.pdf PDF
Attachment 5 Seed Proj FXSB 21-1058 SOW SPECS DRAWINGS v2.pdf PDF
Solicitation Amendment No. 1_FA500021R00230001.pdf PDF
Attachment 1 Wage Determination.pdf PDF
Attachment 2 MACC SOW(CAO 3 May 21).pdf PDF
Attachment 8 Past Performance Tabs A-B 20210401.xlsx XLSX spreadsheet
Attachment 13 JBER Richardson IFS_PreFinal.pdf PDF
Attachment 15 JBER Hazardous Waste Management Plan - 7 May 2020.pdf PDF
Attachment 19 NAFI General Provisions and Clauses.pdf PDF
Attachment 18 DD1354 _ FILLABLE Template _ AUG2013.pdf PDF
Solicitation - FA500021R0023.pdf PDF
Attachment 3 Seed Proj FXSB 20-5254 SOW SPECS DRAWINGS.pdf PDF
Attachment 6 Seed Project FXSB 21-1058 Price Schedule.pdf PDF
Attachment 7 PPQ 20210113.pdf PDF
Attachment 9 673ABW3 Dig Permit (2020 Version).pdf PDF
Attachment 11 Weather Data.pdf PDF
Attachment 12 JBER Telecommunications Installation Standards18DEC2018.pdf PDF
Attachment 16 Contractors Fire Safety Guide.pdf PDF
Attachment 20 ENV_PRECON Checklist_2020.pdf PDF
Attachment 21 REVISED JBER CAD GIS RECORD DRAWING DESIGN AND AS BUILT STANDARD Dec 2019.pdf PDF
Attachment 22 PPCL 20210519.pdf PDF
Attachment 4 Seed Project FXSB 20-5254 Price Schedule.pdf PDF
Attachment 14 JBER Richardson IFS_Pre-Final.pdf PDF
Attachment 17 Teaming consent 20201208.pdf PDF
Attachment 10 Financial Data Form 20201208.pdf PDF
Show all 44

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 1: SCOPE OF WORK

01020

03/12/2021

1. GENERAL:

1.1. Intent is to renovate the restrooms in building 13373, and convert the existing closet in the southwest corner of the building closet into a restroom.

1.2. If the codes contradict each other regarding a specific requirement, the contractor is to use the most stringent requirement.

1.3. The contractor shall limit the work to the areas indicated by the government. The contractor shall make every effort not to disturb or obstruct portions of the facilities still occupied by the government. The contractor shall make efforts to minimize interference to Government operations. The contractor shall dispose of all construction debris off base at an approved disposal facility.

1.4. Power Outages: if required, any power outage notifications must be sent to government a minimum of 2 weeks prior with a 24 hour confirmation notification prior to outage.

1.5. Water outages: Any water outages must be preceded with a minimum of 2 weeks notification with a 24 hour confirmation notification prior to the water outage.

1.6. Site Storage: On site storage outside of the project area is limited. The contractor shall minimize storage of materials and equipment on site.

1.7. A Civil Engineer Work Clearance request (673 ABW Form 3) is required to be completed before starting with any work. Contractor shall check with the appropriate authorities for Gas, Electric, Comm, Sewer, Storm and Water lines prior to beginning work.

1.8. A Storm Water Pollution Prevention Plan (SWPPP) is not required for this project;

however, best management practice will be followed.

1.9. DAMAGE TO EXISTING SITE CONDITIONS: The contractor shall be responsible to repair any and all damage incurred to existing Real Property/Grounds at no cost to the government. Contractor shall not park or drive on, sidewalk or grassy/snowy areas.

Damage incurred shall be repaired at no cost to the government.

1.10. Contractors are strongly encouraged to visit the site and get familiar with all the work related to the project prior to submitting a bid, to verify existing site condition and other information as noted in the scope of work and drawings, as well as to become familiar with the scope of work. Failure to visit the site does not relieve the Contractor from the responsibility of performing all work required to provide a complete and useable project in accordance with the Contract documents.

FA500021R0023-JBER MACC

Attachment 5-Seed Proj FXSB 21-1058

SOW SPECS DRAWINGS

1.11. Sketches provided are not for construction. Contractor must create their own construction shop drawings and submit to the government for approval prior to starting work on site.

1.12. It is the inherent responsibility of the Contractor to practice good fire prevention measures while working on Elmendorf Air Force Base, including the use of a fire watch.

1.13. Protection of Existing Utilities: The Contractor shall safeguard and protect from damage all utilities encountered or uncovered during work. Any damaged utilities caused by contractor’s negligence shall be repaired immediately at no additional cost to the government.

1.14. COVID Base Access Information: When work under this contract requires entry to controlled or restricted areas, the contractor shall comply with AFI 31-101, Integrated Defense, and DODMAN5200.02_AFMAN 16-1405, Air Force Personnel Security Program. Contractors requiring access to any area on Joint Base Elmendorf- Richardson (JBER) shall comply with installation, state, and local COVID-19 policies and mandates and respect any guidelines or restrictions imposed by local businesses. These policies and mandates frequently change. COVID-19 policies and mandates are found at https://www.jber.jb.mil/Coronavirus/ for JBER COVID-19 Policy Memo, https://covid19.alaska.gov/ for State of Alaska COVID-19 Coronavirus Information, and https://covid-responsemoa- muniorg.hub.arcgis.com/pages/emergency-orders for the Municipality of Anchorage Emergency Orders. Failure to comply with the guidelines or restrictions may result in suspended access to JBER or debarment. Contractors shall comply with the above-referenced documents] citing the appropriate paragraphs as applicable.

1.15. Facility is located on a secured airfield and will require escorts from the facility user, as well as advanced scheduling.

2. DEMOLISH: *** Before starting excavation, schedule a meeting with project inspector to perform a site walk to confirm demolition scope of work and mark items to be removed.

2.1. Existing Restrooms: Demolish and dispose of existing fixtures, plumbing, partitions, cove base, ceiling, lighting, and smoke detectors. Demolish plumbing and electrical only so far as required to reinstall new fixtures, lighting, and heat detectors.

2.2. Ceiling: Demolish and dispose of existing ceiling, insulation, and debris on ceiling. Walls are to be maintained.

3. NEW WORK:

3.1. Plumbing: Install hot and cold water supply using Type L copper with soldered or copper-press-joining-system joints to all fixtures. Install isolation ball valves in each restroom in accessible locations for maintenance.

FA500021R0023-JBER MACC

3.2. Walls: Repair damaged locations. Install fiber-reinforced plastic full height from floor to ceiling on all interior walls of the restrooms. Install cove base in same location as FRP.

Coordinate finish and color selection with user and 673rd CES prior to installation.

3.3. Floor: Clean existing concrete slab and seal with a commercial sealant.

3.4. HVAC: Install new vent covers, vent ductwork, radiant baseboard covers, and diffusers for all existing vents, baseboards, and diffusers. Install new exhaust fans in both rooms.

Fully duct both exhaust fans to exterior of the building. Penetration to exterior of the building shall be sealed with wire mesh or flapper to prevent bird entry. Coordinate material and equipment selection as well as color selection with user and 673rd CES prior to installation. Exhaust fans to be separately activated via new occupancy sensors installed by the contractor.

3.4.1. In existing restroom, install minimum 180 CFM exhaust fan

3.4.2. In closet being converted to a restroom, install minimum 100 CFM exhaust fan

3.5. Ceiling: Install new finished insulated ceiling. Ceiling joists to be 2x8 on 12 inch centers, assuming Douglas Fir-Larch #2. Install ½ inch gypsum wallboard to underside of joists.

Mud and tape to level 4 finish. On top of joists install 19/32 inch plywood. Paint “MAX LOAD 20 PSF” on top of ceiling.

3.6. Paint: For all areas not covered by FRP, including both sides of ceiling and outer walls of bathrooms and FAP closet, install primer and two coats of commercial grade latex paint. Coordinate paint finish and color selection with user and 673rd CES prior to installation.

3.7. Doors: Install new solid core commercial grade doors with steel frames and stainless steel hardware at all locations indicated in the drawings. Doors shall be installed with closers. Stops shall be installed to prevent wall damage for each door if needed.

3.7.1. Install Best MX8B interchangeable core keying system, as well as cylinder that will receive these cores, with 7 pin IC small format as shown on the plans.

Contractor shall provide any removed door locks and/or cores to 773 CES/CEOHS Lock Shop prior to demolition/renovation.

3.8. Lighting: Install LED lighting in ceilings. Coordinate light fixture selection with user and 673rd CES prior to installation. Lighting to be separately activated via new occupancy sensors installed by the contractor.

3.9. Occupancy sensors: Install occupancy sensors in all rooms. Sensors shall be spaced so all areas are covered.

3.10. Pressure Jet and clean the existing sewer line. Piping will be free of any visible foreign material. Approximately 250 linear feet will need to be cleaned and jetted.

Conduct sewer camera inspection and documentation of all sanitary sewer piping out to the first manhole. Provide thorough video and documentation of all piping joints, connections, any and all low spots and imperfections.

FA500021R0023-JBER MACC

3.11. Fixtures:

3.11.1. Toilets: Install commercial grade toilet fixtures as noted on the drawings. Toilet selection shall be coordinated with user and 673rd CES prior to installation. Connect to water supply and DWV piping. Toilets shall be equipped with touchless sensor activation.

3.11.2. Urinals: Install commercial grade urinal fixtures as noted on the drawings. Urinal selection shall be coordinated with user and 673rd CES prior to installation. Connect to water supply and DWV piping. Toilets shall be equipped with touchless sensor activation.

3.11.3. Sinks: Install commercial grade sink/lavatory fixtures as noted on the drawings.

Sink/lavatory selection shall be coordinated with user and 673rd CES before installation. Connect to water supply and DWV piping. Flexible connections shall be braided stainless only. Sinks shall be equipped with touchless sensor activation.

3.11.4. Partitions: Install solid phenolic partitions and doors as indicated on the drawings. Coordinate color and finish with user and 673rd CES before installation.

FA500021R0023-JBER MACC

MAP KEY

LOCATION DESCRIPTION

RICHARDSON VISITORS GATE

ARCTIC VALLEY GATE GLENN HWY SOUTHBOUND EXIT

ELMENDORF VISITORS GATE

654 6TH STREET: FIRE STATION 4

8517 20TH STREET: SECURITY FORCES

CLEAN FILL LANDFILL SITE

CONCRETE LANDFILL SITE

POST ROAD GATE

BUILDING 13373

PROJECT LOCATION

JOINT BASE ELMENDORF-RICHARDSON

673RD CIVIL ENGINEER SQUADRON

KEY PLAN

A B C D E F G H I

SHEET

REFERENCE

NUMBER

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

PLOT SCALE:

SYMBOL DATE DESCRIPTION

REVISIONS

JOINT BASE ELMENDORF-RICHARDSON, AK

DESIGNED BY:

DRAWN BY:

CHECKED BY:

PROJ. ENG.

DESIGN

DRAWINGS

1:1

AF CONTRACT NUMBER:

INV. NUMBER:

DATE APPR

DATE:

DATE:

DATE:

DATE:

DRAWING NO:

U.S. AIR FORCE

01 MAR 2021

03/01/2021

03/01/2021

N

RPR MODIFY TRAFFIC PATTERNS - TRAFFIC

CALMING GOV'T HILL & POST ROAD

FXSB 19-5239 & FXSB 19-5240

ANSI

D

PRELIMINARY

C-1

PROJECT LOCATION

SCHEDULE OF DRAWINGS

SHEET NUMBER SHEET TITLE

C-1 COVER SHEET

AD 100 DEMOLITION SHEET

A-100 REMODEL SHEET

1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS.

2. AT NO TIME WILL THE CONTRACTORS WORK, STORAGE OF MATERIALS, PARKING OF VEHICLES OR OTHER ACTIVITIES BE ALLOWED TO INTERFERE WITH THE WORK ACTIVITIES OF GOVERNMENT PERSONNEL OR TO DAMAGE GOVERNMENT OR PRIVATE PROPERTY.

3. THE CONTRACTOR SHALL AT ALL TIMES KEEP THE WORK AREA FREE FROM ACCUMULATION OF WASTE MATERIALS. DEBRIS SHALL BE REMOVED ON A DAILY

BASIS.

4. ALL WELDING AND / OR THE USE OF FLAME PRODUCING DEVICES SHALL BE CLEARED THROUGH THE FIRE DEPARTMENT.

5. ALL CONSTRUCTION PERMITS, FEES AND COORDINATION OF ANCILLARY ITEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.

6. THE WORK OF THIS CONTRACT SHALL COMPLY WITH APPLICABLE FEDERAL, STATE AND LOCAL CODES OR STANDARDS, INCLUDING BUT NOT LIMITED TO:

ENVIRONMENTAL PROTECTION AGENCY, NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, NATIONAL FIRE PROTECTION ASSOCIATION, OSHA

STANDARDS, FIRE CODES, INTERNATIONAL BUILDING CODE.

PROJECT NOTES:

COVER SHEET

FA500021R0023-JBER MACC

A B C D E F G H

F I L

E

N

O

I

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

D E

S C

R I P

T I O

N

R E

V I S

I O

N S

RICHARDSON, ALASKA

AF CONTRACT NUMBER:

FACILITY NO:

D A

T E

A P

P R

O V

E R

JOINT BASE ELMENDORF

PROJ. MGR:

DRAFTER:

CHECKER:

PROJ. ENGR:

DATE:

DATE:

DATE:

DATE:

DESIGNER LOGO

AIR FORCE

S Y

M B

O L

D A

T E

AD100

DEMOLITION

PLAN

REPAIR

RESTROOMS

AMS

13373

FXSB191080AD100

FXSB 21-1058

NTS

DEMOLITION FLOOR PLAN

KEY PLAN

PROJECT

LOCATION

DEMOLITION NOTES:

REMOVE EXISTING SINKS

REMOVE EXISTING TOILETS

REMOVE EXISTING URINALS.

REMOVE DOOR, FRAME AND HARDWARE.

REMOVE TOILET PARTITIONS.

REMOVE CEILING.

DEMO ELECTRICAL & PLUMBING ONLY AS NEEDED.

REMOVE COVE BASE

LEGEND:

DEMO PARTITION

DEMO DOOR.

DEMO TOILET.

DEMO URINAL

DEMO SINK

2 2

3 3

4 4

FA500021R0023-JBER MACC

Attachment 5-Seed Proj FXSB 21-1058

SOW SPECS DRAWINGS

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

BUILDING: 13373

AutoCAD SHX Text

FLOOR: 1

AutoCAD SHX Text

STORAGE FACILITY

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

CLOSET

A B C D E F G H

F I L

E

N

O

I

SHEET

REFERENCE

NUMBER

ANSI

D

AF PROJECT NUMBER:

AEC FILE NAME:

DRAWING SCALE:

D E

S C

R I P

T I O

N

R E

V I S

I O

N S

RICHARDSON, ALASKA

AF CONTRACT NUMBER:

FACILITY NO:

D A

T E

A P

P R

O V

E R

JOINT BASE ELMENDORF

PROJ. MGR:

DRAFTER:

CHECKER:

PROJ. ENGR:

DATE:

DATE:

DATE:

DATE:

DESIGNER LOGO

AIR FORCE

S Y

M B

O L

D A

T E

A100

DEMOLITION

PLAN

REPAIR

RESTROOMS

AMS

13373

FXSB191080AD100

FXSB 21-1058

NTS

NEW REMODEL FLOOR PLAN

KEY PLAN

PROJECT

LOCATION

Ø5'

SINGLE

USE

UNISEX

MENS

CONSTRUCTION NOTES:

INSTALL SOLID CORE DOOR, STEEL FRAME, STAINLESS

HARDWARE, AND CLOSURE

INSTALL 1 ADA COMPLIANT TOILET

INSTALL 1 ADA COMPLIANT SINK

INSTALL 1 MEN'S SINK

INSTALL 2 EACH MEN'S TOILET AND STALL

INSTALL 2 URINALS

INSTALL COVE BASE

INSTALL FRP WALL COVERING FULL HEIGHT FROM FLOOR

TO CEILING

INSTALL NEW FINISHED CEILING WITH LED LIGHTING. PAINT

"MAX LOAD 20 PSF" ON TOP OF CEILING

ALL FIXTURES SHALL HAVE AUTOMATIC HARDWARE

CLEAN AND SEAL CONCRETE FLOOR

INSTALL SIGNS ON DOOR STATING RESTROOM USE TYPE

(MENS, SINGLE USE UNISEX, OR 673 CES APPROVED

EQUIVALENT)

INSTALL PRIVACY LOCK

INSTALL STOREROOM LOCK WITH BEST LOCKS MX8 CORE

INSTALL SIGN ON DOOR STATING "FAP INSIDE"

INSTALL SIGN ON WALL STATING "MAX LOAD 20 PSF"

FA500021R0023-JBER MACC

Attachment 5-Seed Proj FXSB 21-1058

SOW SPECS DRAWINGS

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

BUILDING: 13373

AutoCAD SHX Text

FLOOR: 1

AutoCAD SHX Text

STORAGE FACILITY

AutoCAD SHX Text

BATHROOM

AutoCAD SHX Text

CLOSET

P a c i f i c G e o B a s e T a b l o i d [ A N S I B - L a n d s c a p e ] P a c i f i c G e o B a s e T a b l o i d [ A N S I B - L a n d s c a p e ] µ

0.025 0 0.025 0.05 0.075 0.10.0125 mi

0.045 0 0.045 0.09 0.135 0.180.0225 km

UNCLASSIFIED // CONTROLLED UNCLASSIFIED INFORMATION

EXHIBIT DRAWING

FA500021R0023-JBER MACC

EXHIBIT DRAWING

FA500021R0023-JBER MACC

01020 SOW 20210414
SECTION 1: SCOPE OF WORK
9. FXSB 21-1058 Drawings
Sheets and Views
Cover Sheet
2. Demo sheet 20210312.pdf
Sheets and Views
Layout1
3. Remodel sheet 20210312.pdf
Sheets and Views
Layout1

File details come from the government source that posted it. Updated .