This is an invitation for bid (IFB) for construction services. The Department of Veterans Affairs is seeking a contractor to provide EHRM Training and Admin Space Support construction services at the Clement J. Zablocki VA Medical Center located in Milwaukee, Wisconsin. Key project details include renovating approximately 12,000 square feet of existing office and training space in buildings 6 and 20 on the medical center campus. The construction work includes demolition, hazardous material abatement, finish upgrades, mechanical/electrical/plumbing system work, and site work. The period of performance is 720 calendar days from NTP. Bids are due by 2:00 PM Central Time on March 10, 2022 and the contract is a 100% small business set-aside.
View the file
Other files for this federal contract opportunity
Show all 40
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CONTRACT OFFICER REPRESENTATIVE DATE
CHIEF OF ENGINEERING DATE
INTERIOR DESIGNER DATE
DEPARTMENT HEAD DATE
CONTRACT SPECIALIST DATE LEAD USER SIGNATURE DATE
B D
BUILDING 6 FIRST FLOOR KEY PLAN
N
SHADE INDICATES AREA
NOT IN SCOPE, TYP
NO SHADE INDICATES
LOCATION OF PROJECT,
TYP
A
SOUTH
C
SOUTH
C
NORTH
A
NORTH
A
SOUTH
B D
BUILDING 6 BASEMENT KEY PLAN
N
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
NO SHADE INDICATES
LOCATION OF PROJECT,
TYP
C
SOUTH
C
NORTH
A
NORTH
A
SOUTH
B D
BUILDING 6 SECOND FLOOR KEY PLAN
N
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
NO SHADE
INDICATES
LOCATION OF
PROJECT, TYP
C SOUTH
C
NORTHA
NORTH
2ND FLR PORCH NIC
D
BUILDING 6 THIRD FLOOR KEY PLAN
N
HATCH INDICATES
ROOF AREA
BELOW, NIC
NO SHADE
INDICATES
LOCATION OF
PROJECT, TYP
C SOUTH
C
NORTH
(ROOF
ONLY)
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C U s e rs
\d v a lla n d in g h a m \D o c u m e n ts
\1
.1
.2
A v d v a lla n d in g h a m g u id o n d e s ig n .c o m
.r v t
/1 /2
:3
:0
P M
GI000
COVER SHEET
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
695-21-703
EHRM TRAINING AND ADMIN SPACE SUPPORT
CLEMENT J. ZABLOCKI VAMC
5000 West National Avenue, Milwaukee, WI 53295
BID DOCUMENTS
BID DOCUMENTS
FULLY SPRINKLERED
SHEET INDEX
SHEET
NUMBER SHEET NAME
FIRE PROTECTION
FX101 BASEMENT FIRE SUPPRESSION PLAN - A-WING
FX102 BASEMENT FIRE SUPPRESSION PLAN - C-WING
FX103 FIRST FLOOR FIRE SUPPRESSION PLAN - A-WING
FX104 FIRST FLOOR FIRE SUPPRESSION PLAN - C-WING
FX105 SECOND & THIRD FLOOR FIRE SUPPRESSION PLAN
FX401 FIRE SUPPRESSION RISER SECTIONS
PLUMBING
P000 PLUMBING SYMBOLS AND ABBREVIATIONS
PD100 BASEMENT - C-WING - PLUMBING DEMOLITION PLAN
PP100 BASEMENT - C-WING - PLUMBING PIPING PLAN
PP102 FIRST FLOOR - C-WING - PLUMBING PIPING PLAN
PP400 PLUMBING ENLARGED PLANS
PP500 PLUMBING DETAILS
PP600 PLUMBING SCHEDULES
PP700 PLUMBING SCHEMATICS AND RISERS
MECHANICAL
M000 MECHANICAL SYMBOLS AND ABBREVIATIONS
MD100 BASEMENT - C-WING - MECHANICAL DEMOLITION PLANS
MD101 FIRST FLOOR - A-WING - MECHANICAL DEMOLITION PLAN
MD102 FIRST FLOOR - C-WING - MECHANICAL DEMOLITION PLANS
MD103 SECOND & THIRD FLOOR MECHANICAL DEMOLITION PLANS
MH100 BASEMENT - C-WING - MECHANICAL HVAC PLANS
MH101 FIRST FLOOR - A-WING - MECHANICAL HVAC PLANS
MH102 FIRST FLOOR - C-WING - MECHANICAL HVAC PLANS
MH103 SECOND AND THIRD FLOOR - C-WING - MECHANICAL HVAC PLANS
MP100 BASEMENT - A/B WING - MECHANICAL PIPING PLANS
MP101 BASEMENT - C-WING - MECHANICAL PIPING PLAN
MP102 FIRST FLOOR - A-WING - MECHANICAL PIPING PLANS
MP103 FIRST FLOOR - C-WING - MECHANICAL PIPING PLANS
MP104 SECOND AND THIRD FLOOR - C-WING - MECHANICAL PIPING PLAN
MM400 MECHANICAL ENLARGED PLANS
MM500 MECHANICAL DETAILS
MM501 MECHANICAL DETAILS
MM600 MECHANICAL SCHEDULES
MM700 MECHANICAL CONTROL SYSTEMS
ELECTRICAL
E000 ELECTRICAL SYMBOLS AND ABBREVIATIONS
EDL100 BASEMENT - C-WING - LIGHTING DEMOLITION PLANS
EDL101 FIRST FLOOR - A-WING - LIGHTING DEMOLITION PLANS
EDL103 FIRST FLOOR - C-WING - LIGHTING DEMOLITION PLANS
EDL104 SECOND & THIRD FLOOR - C-WING - LIGHTING DEMOLITION PLANS
EDP100 BASEMENT - C-WING - POWER DEMOLITION PLANS
EDP101 FIRST FLOOR - A-WING - POWER DEMOLITION PLANS
EDP102 FIRST FLOOR - B-WING - POWER DEMOLITION PLAN
EDP103 FIRST FLOOR - C-WING - POWER DEMOLITION PLANS
EDP104 SECOND & THIRD FLOOR - C-WING - POWER DEMOLITION PLANS
EL100 BASEMENT - C-WING - LIGHTING PLANS
EL101 FIRST FLOOR - A-WING - LIGHTING PLANS
EL103 FIRST FLOOR - C-WING - LIGHTING PLANS
EL104 SECOND & THIRD FLOOR - C-WING - LIGHTING PLANS
EP100 BASEMENT - C-WING - POWER PLANS
EP101 FIRST FLOOR - A-WING - POWER PLANS
EP102 FIRST FLOOR - B-WING - POWER PLAN
EP103 FIRST FLOOR - C-WING - POWER PLANS
EP104 SECOND & THIRD FLOOR - C-WING - POWER PLANS
EP300 ELECTRICAL ENLARGED PLANS
EP400 ELECTRICAL ONE-LINE DIAGRAM
EP500 ELECTRICAL DETAILS
EP501 ELECTRICAL DETAILS
EP600 ELECTRICAL SCHEDULES
EP601 ELECTRICAL SCHEDULES
EP602 ELECTRICAL SCHEDULES
TELECOMMUNICATION
EX000 BASEMENT DEMOLITION PLANS - C-WING
EX001A FIRST FLOOR DEMOLITION PLAN - A-WING
EX001B FIRST FLOOR DEMOLITION PLAN - C-WING
EX002 SECOND FLOOR DEMOLITION PLAN - C-WING
EX003 THIRD FLOOR DEMOLITION PLAN - C-WING
ET001 LEGEND AND ABBREVIATIONS
ET500 TECHNOLOGY DETAILS
ET100 BASEMENT TECHNOLOGY PLAN - C-WING
ET101A FIRST FLOOR TECHNOLOGY PLAN - A-WING
ET101B FIRST FLOOR TECHNOLOGY PLAN - C-WING
ET102 SECOND FLOOR TECHNOLOGY PLAN - C-WING
ET103 THIRD FLOOR TECHNOLOGY PLAN - C-WING
EY100A BASEMENT AUXILIARY SYSTEMS PLANS - A-WING
EY100B BASEMENT AUXILIARY SYSTEMS PLAN - C-WING
EY101A FIRST FLOOR AUXILIARY SYSTEMS PLAN - A-WING
EY101B FIRST FLOOR AUXILIARY SYSTEMS PLAN - C-WING
EY102 SECOND FLOOR AUXILIARY SYSTEMS PLAN - C-WING
EY103 THIRD FLOOR AUXILIARY SYSTEMS PLAN - C-WING
SHEET INDEX
SHEET
NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI101 LIFE SAFETY PLANS - BASEMENT AND FIRST FLOOR
GI102 LIFE SAFETY PLANS - SECOND AND THIRD FLOOR
GC101 INFECTION CONTROL / CONSTRUCTION LOGISTICS PLAN
HA100 HAZMAT. ABATEMENT BUILDING 20 AND 6 BASEMENT PLAN
HA101 HAZMAT. ABATEMENT 1ST, 2ND, AND 3RD FLOOR PLAN
CIVIL
CI001 CIVIL GENERAL NOTES
CD101 SITE DEMOLITION PLAN
CD102 SITE DEMOLITION PLAN
CS101 SITE LAYOUT PLAN
CS102 SITE LAYOUT PLAN
CS501 SITE DETAILS
CG101 GRADING AND UTILITY PLAN
CG102 GRADING AND UTILITY PLAN
STRUCTURAL
SI001 STRUCTURAL GENERAL NOTES
SF101 BUILDING 6 STRUCTURAL PLAN - BASEMENT
SF102 BUILDING 6 STRUCTURAL PLAN - FIRST FLOOR
SF103 BUILDING 20 STRUCTURAL PLAN
SF501 STRUCTURAL SECTIONS AND DETAILS
ARCHITECTURAL
AD100 BASEMENT - A- WING AND C-WING - DEMOLITION PLANS
AD101 FIRST FLOOR - A-WING AND B-WING - DEMOLITION PLANS
AD102 FIRST FLOOR - C-WING - DEMOLITION PLANS
AD103 2ND AND 3RD FLOOR AND ROOF - C-WING DEMOLITION - PLANS
AD104 BUILDING 20 - THIRD FLOOR - DEMOLITION PLAN
AE001 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS
AE002 WALL TYPES
AE100 BASEMENT - C-WING - ARCHITECTURAL PLAN
AE101 FIRST FLOOR - A-WING AND B WING - ARCHITECTURAL PLANS
AE102 FIRST FLOOR - C-WING - ARCHITECTURAL PLANS
AE103 SECOND & THIRD FLOOR - C-WING - ARCHITECTURAL PLANS
AE104 ROOF - C-WING - ARCHITECTURAL PLAN AND DETAILS
AE105 BUILDING 20 - THIRD FLOOR - ARCHITECTURAL PLAN
AE110 BASEMENT - C-WING - REFLECTED CEILING PLAN
AE111 FIRST FLOOR - A-WING NORTH - REFLECTED CEILING PLANS
AE112 FIRST FLOOR - C-WING - REFLECTED CEILING PLAN
AE113 SECOND & THIRD FLOOR - C-WING - REFLECTED CEILING PLANS
AE201 A-WING - PORCH - ELEVATIONS
AE321 A-WING WOOD STAIR & RAMP PLANS AND SECTIONS
AE322 A- WING AND C-WING - EXTERIOR STAIR PLANS & SECTIONS
AE323 C-WING - INTERIOR STAIR PLANS & SECTIONS
AE324 C-WING - ELEVATOR PLANS & ELEVATIONS
AE401 WALL SECTIONS
AE501 BUILDING DETAILS
AE601 DOOR AND WINDOW SCHEDULE
AI100 BASEMENT - C-WING - FINISH PLANS
AI101 FIRST FLOOR - A-WING AND B WING - FINISH PLANS
AI102 FIRST FLOOR - C-WING - FINISH PLANS
AI103 SECOND & THIRD FLOOR - C-WING - FINISH PLANS
AI201 INTERIOR FINISHES ENLARGED PLANS & ELEVATIONS
AI202 INTERIOR FINISHES ENLARGED PLANS & ELEVATIONS
AI501 INTERIOR FINISHES AND CASEWORK DETAILS
AI601 FINISH SCHEDULES
AI900 BASEMENT - C-WING - SIGNAGE PLANS
AI901 FIRST FLOOR - A-WING AND B WING- SIGNAGE PLANS
AI902 FIRST FLOOR - C-WING - SIGNAGE PLANS
AI903 SECOND & THIRD FLOOR - C-WING - SIGNAGE PLANS
AI904 INTERIOR SIGNAGE AND EQUIPMENT SCHEDULES
AI905 SIGNAGE TYPES
QH100 BASEMENT - C-WING - EQUIPMENT PLAN
QH101 FIRST FLOOR- A-WING AND C WING - EQUIPMENT PLAN
Contact:Contact:Contact:Contact: Contact: Contact:
GUIDON DESIGN INC.
Chris Hawk
Sr. Project Manager
MECHANICAL,
ELECTRICAL &
PLUMBING
GUIDON DESIGN INC.
Lauren Lai
Structural Engineer
STRUCTURAL
ENGINEER
GUIDON DESIGN INC.
Chad Butler
Civil Engineer
1221 North Pennsylvania Street Indianapolis, IN 46202 p: 317.800.6388 x 108 e: cbutler@guidondesign.com
CIVIL
ENGINEER
CLEMENT J. ZABLOCKI VAMC
Andrew Jacobs
COR
5000 West National Avenue, Milwaukee, WI 53295 p: 474.384.2000 x 45768 e: andrew.jacobs3@va.gov
OWNER
GUIDON DESIGN INC.
David Vallandingham
Project Manager
1221 North Pennsylvania Street Indianapolis, IN 46202 p: 317.800.6388 x 130 e: dvallandingham@guidondesign.com
ARCHITECT
FFE Inc.
Jack Bonbright
Senior Electrical Engineer
INFORMATION
TECHNOLOGY
1221 North Pennsylvania Street Indianapolis, IN 46202 p: 317.800.6388 x 117 e: llai@guidondesign.com
1221 N. Pennsylvania St.
Indianapolis IN 46202 p: 317-800-6388 ext 167 e: chawk@guidondesign.com
110 Boggs Lane, Suite 170 Cincinnati, OH 45246 p: 513-235-8466 e: jack.bonbright@ffeinc.us
CAMPUS MAP
AREA MAP
VICINITY MAP
N
N
N
PROJECT LOCATION
PROJECT LOCATION:
BUILDING 6
PROJECT LOCATION:
BUILDING 20
Revisions: Date:
UP
REFERENCE DESIGN CODES
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
CODE ANALYSIS LEGEND
FHC
FIRE HOSE CABINET
B -W
IN
G
C -W
IN
G
C -W
IN
G
D -W
IN
G
E X
IT
EXIT
EXIT
FEC
FHC
EXIT SEPARATION
DISTANCE: 101'-0"
TRAVEL
DISTANCE: 96'-3"
TRAVEL
DISTANCE: 98'-3"
STORAGE
CB15
ELEC. ROOM
CB16
CIRC.
CB17
ELEV. LOBBY
CB22
ELEV.
C2-P
DHW / UTILITY
CB21
IT ROOM
CB18-C
STAIR C2
C2
CORRIDOR C
CB12
ELEV.
C1-P
ELEV. EQUIP.
CB11
RR-MENS
CB06
CIRC.
CB08
ELECTRICAL
CLOSET
CB09
RR-WOMEN'S
CB10
CIRC.
CB07
STAIR C1
C1
MECHANICAL
CB42
VESTIBULE
CB50
CORRIDOR
CB40
TRAINING
CB45
TRAINING
CB43
TRAINING
CB41
FM OFFICE
CB05
VESTIBULE
CB24
TRAINING
CB48
TRAINING
CB46
TRAINING
CB44
STAIR
CB4
STORAGE
CB49
VESTIBULE
CB22A
CIRC.
CB23
STORAGE
CB18
WOMENS RR
CB19-A
MENS RR
CB19-B
6 TRAINING ROOMS
POSTED MAX
OCCUPANCY: 16
REMAINDER OF WING C
FIRST FLOOR,
EXCLUDING TRAINING
ROOMS: 5,787 SF
39 OCCUPANTS @ 150
PER SF
STAIRS HAVE 1 HR
ENCLOSURE PER
IBC 1023.2
B -W
IN
G
C -W
IN
G
C -W
IN
G
D -W
IN
G
A -W
IN
G
B -W
IN
G
E X
IT
EXIT
E X
IT
EXIT
E X
IT
FEC
FEC
FEC
FHC
FEC
NORTH
SOUTH
EXIT SEPARATION
DISTANCE: 66'-8"
NO LIFE SAFETY CHANGES
PROPOSED TO EXISTING
CORRIDOR
EXIT SEPARATION
DISTANCE: 92'-3"
D
IA
G O
N A
L D
IS
T
A N
C E
: 8 4'
-0
TRAVEL
DISTANCE: 86'-3"
TRAVEL
DISTANCE: 115'-8"
CIRC.
C116
CORRIDOR
C115B
CORRIDOR
C115A
ELEV.
C2-P
ELEV. LOBBY
C120
SECURITY
C118-A
WAITING
C142
STORAGE
C119-C
STAIR C2
C2
CORRIDOR
B/C
CORRIDOR
A101
MECHANICAL
A121
BREAKOUT
A122
TRAINING
A124
STAIR
C106
CORRIDOR
A/B
ELEV. EQUIP.
CB11
MECHANICAL
C126
TRAINING
A118-A
IT ROOM
C118-B
TRAINING
C106-C
DATA CLOSET
B103
OIT CLOSET
A104
TRAINING
C145
TRAINING
C143
TRAINING
C141
TRAINING
C146
TRAINING
C144
CORRIDOR
C140
TRAINING
C148
WOMENS RR
C119-A
BREAK AREA
C118
STAIR
C4
MENS RR
C119-B
CIRC.
A117
STORAGE
A116-C
WAITING
C124
CONFERENCE ROOM
C124-AELEV. MACHINE.
C121
TRAINING
A118-B
EXIT SEPARATION
DISTANCE: 77'-0"
6 TRAINING ROOMS
POSTED MAX
OCCUPANCY: 16
REMAINDER OF WING C
FIRST FLOOR,
EXCLUDING TRAINING
ROOMS: 5,787 SF
39 OCCUPANTS @ 150
PER SF
3 TRAINING ROOMS
POSTED MAX
OCCUPANCY: 16
STAIRS HAVE 1 HR
ENCLOSURE PER
IBC 1023.2
STAIRS HAVE 1 HR
ENCLOSURE PER
IBC 1023.2
CORRIDOR
C/D
CORRIDOR
D
B D
BUILDING 6 FIRST FLOOR KEY PLAN
N
SHADE INDICATES AREA
NOT IN SCOPE, TYP
NO SHADE INDICATES
LOCATION OF PROJECT,
TYP
A
SOUTH
C
SOUTH
C
NORTH
A
NORTH
A
SOUTH
B D
BUILDING 6 BASEMENT KEY PLAN
N
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
NO SHADE INDICATES
LOCATION OF PROJECT,
TYP
C
SOUTH
C
NORTH
A
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C
U s e rs \c s u tt o n \D o c u m e n ts
\1
.1
.2
A v c s u tt o n B
F V
.r v t
/1 /2
:0
:4
A
M
GI101
LIFE SAFETY PLANS - BASEMENT
AND FIRST FLOORGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/16" = 1'-0"GI101
1 BUILDING 6 BASEMENT C-WING LIFE SAFETY PLAN
SCALE: 1/16" = 1'-0"GI101
2 BUILDING 6 FIRST FLOOR LIFE SAFETY PLAN
N N
STAIR
C205
69' - 6" DIAG
O
NAL DISTANCE
/2
C -W
IN
G
D -W
IN
G
EXIT
2,636 SF C-WING
SOUTH 2ND FLOOR:
18 OCCUPANTS @ 150
PER SF
STAIRS HAVE 1 HR
ENCLOSURE PER
IBC 1023.2
ELEVATOR
OFFICE
C304
RECEPTION
C308
OFFICE
C307
OFFICE
C302
STAIR C1
C1
ETR
C303
OPEN OFFICE
C305
STAIR
C306
CORRIDOR
C3A
ELEVATOR C1
C1
RESTROOM
C301-A
UTILITY
C301-B
69' - 6" DIAG
O
NAL DISTANCE
E X
IT
S
E P
A R
A T
IO
N
C -W
IN
G
D -W
IN
G
EXIT
EXIT
EXIT ACCESS TRAVEL
DISTANCE: 51'-3"
2,636 SF C WING
3RD FLOOR:
18 OCCUPANTS @
150 PER SF
STAIRS HAVE 1 HR
ENCLOSURE PER
IBC 1023.2
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
CODE ANALYSIS LEGEND
FHC
FIRE HOSE CABINET
A
SOUTH
B D
BUILDING 6 SECOND FLOOR KEY PLAN
N
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
NO SHADE
INDICATES
LOCATION OF
PROJECT, TYP
C SOUTH
C
NORTHA
NORTH
2ND FLR PORCH NIC
D
BUILDING 6 THIRD FLOOR KEY PLAN
N
HATCH INDICATES
ROOF AREA
BELOW, NIC
NO SHADE
INDICATES
LOCATION OF
PROJECT, TYP
C SOUTH
C
NORTH
(ROOF
ONLY)
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C
U s e rs \c s u tt o n \D o c u m e n ts
\1
.1
.2
A v c s u tt o n B
F V
.r v t
/1 /2
:0
:5
A
M
GI102
LIFE SAFETY PLANS - SECOND
AND THIRD FLOORGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/16" = 1'-0"GI102
1 BUILDING 6 SECOND FLOOR - C-WING - LIFE SAFETY
SCALE: 1/16" = 1'-0"GI102
2 BUILDING 6 THIRD FLOOR - C-WING - LIFE SAFETY
CONSTRUCTION ACTIVITY - FIRE RISK: TYPE C
PATIENT RISK GROUP: LOW
CLASS OF PRECAUTION MATRIX: CLASS III
INFECTION CONTROL PROJECT INFORMATION
A. BUIDLINGS TO BE OCCUPIED BY STAFF AND VETERANS THROUGHOUT
CONSTRUCTION. TEMPORARY BARRIERS, SIGNAGE, AND TRAVEL ROUTES
SHALL BE COORDINATED WITH VA AND PROVIDED BY CONTRACTOR.
REFER TO LIST OF REQUIRED INFECTION CONTROL PRECAUTIONS OUTLINED
BY CLASS IN SPECIFICATION 010110 AND ADDITIONAL INFORMATION.
B. REFER TO DRAWINGS, SPECIFICATIONS AND DOOR HARDWARE SCHEDULE
FOR ADDITIONAL INFORMATION.
C. COORDINATE FULL SCOPE OF WORK WITH ENGINEERING DRAWINGS AND
FIELD VERIFICATION. CONTRACTOR IS RESPONSIBLE FOR SCOPE OF ABOVE
CEILING WORK REQUIRED ABOVE AND BELOW THE FLOOR PLATE OF THE
PROJECT BOUNDARY.
D. COORDINATE LOCATION OF TEMPORARY INFECTION CONTROL (IC) BARRIER
WALL CONSTRUCTION AND INFECTION CONTROL (IC) MEASURES WITH COR
AND PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE. TEMPORARY
IC BARRIER WALL CONSTRUCTION LOCATIONS IN DRAWINGS ARE
APPROXIMATE. CONTRACTOR SHALL PROVIDE DRAWING TO COR AND
PATIENT SAFETY/ INFECTION CONTROL REPRESENTATIVE ONCE ICRA
PROTOCOLS AND PLAN IS APPROVED.
E. FINISHES ONLY CORRIDOR WORK DOES NOT REQUIRE 1 HR RATED
CONSTRUCTION BARRIER.
F. SCHEDULE AND TIME OF CONSTRUCTION WORK TO BE APPROVED BY COR
AND NURSING STAFF BEFORE CONSTRUCTION MAY BEGIN. PROVIDE
PHASING INFORMATION FOR ABOVE CEILING WORK IN THE CONTRACTOR
PROVIDED CPM SCHEDULE FOR WORK ALSO REQUIRED ABOVE AND BELOW
THE FLOOR PLATE OF THE PROJECT BOUNDARY.
G. ABOVE CEILING WORK SHALL TAKE PLACE BETWEEN THE HOURS OF 5:00 PM
AND 5:00 AM. IN AREAS THAT REQUIRE ABOVE CEILING WORK WHERE
CEILINGS ARE TO REMAIN, CEILING TILES SHALL BE REMOVED AND STORED
IN A SAFE MANNER UNTIL CEILING TILES CAN BE REINSTALLED. DAMAGED
AND BROKEN CEILING TILES SHALL BE REPLACED BY CONTRACTOR.
H. EXIT/ACCESS FOR ADJACENT OPERATIONAL AREAS SHALL BE MAINTAINED
DURING NORMAL BUSINESS HOURS. SEE SPECIFICATION FOR HOURS OF
OPERATION.
I. WORK REQUIRING VIBRATION OR LOAD NOISE SHALL TAKE PLACE BETWEEN
THE HOURS OF 5:00 PM AND 5:00 AM. EVERY EFFORT SHALL BE MADE TO
KEEP NOISE AND VIBRATION TO A MINIMUM.
J. PROVIDE A 24"X36" STICKY WALK OFF MAT AND HAND SANITIZER AT EACH
TEMPORARY DOOR LOCATION. MAT SHALL BE REPLACED OR CLEANED AS
NECESSARY
K. PROVIDE THE VA AND OSHA REQUIRED TEMPORARY SIGNAGE AT EACH
TEMPORARY DOOR LOCATION.
L. CONTRACTOR SHALL SUPPLY SPILL KIT TO INCLUDE SHOP VAC, MULTI-
PURPOSE SPILL CONTROL SORBENTS TO ABSORB NON AGGRESSIVE
LIQUIDS UP TO 30 GALLONS.
M. ALL NEW MATERIAL MOVED THROUGH THE FACILITY SHALL BE COVERED
WITH 6 MIL. POLY SHEET.
N. ALL DEMOLITION MATERIAL SHALL BE REMOVED FROM THE PROJECT
BOUNDARY THROUGH THE FACILITY TO DUMPSTER ALONG VA APPROVED
ROUTE IN ENCLOSED DUMPSTER CART DESIGNED FOR SUCH PURPOSE
WITH A LID.
O. ALL MATERIAL, DEBRIS AND HAZARDOUS MATERIALS SHALL BE PROPERLY
STORED IN DESIGNATED AREAS AND APPROVED CONTAINERS. FLAMMABLE
MATERIALS SHALL NOT BE STORED IN THE FACILITY.
P. PROVIDE CONTAINMENT CART FOR ABOVE CEILING ACCESS OUTSIDE
PROJECT BOUNDARY.
INFECTION CONTROL GENERAL NOTES
PHASE 1: BUILDING 20 AND BUILDING 6 A-WING NORTH
CONTRACTOR SHALL ERECT TEMPORARY CONSTRUCTION BARRIERS AND BEGIN
WORK IN BUILDING 20 AND BUILDING 6 A-WING NORTH DURING PHASE 1 OF
CONSTRUCTION. WORK IN BUILDING 20 SHALL BE COMPLETED AND ACCEPTED BY
THE VA PRIOR TO ANY WORK BEGINNING IN PHASE 2: BUILDING 6 C-WING.
CONTRACTOR SHALL PROVIDE (3) WEEKS BETWEEN PHASE 1 AND 2 TO ALLOW THE
VA TO MOVE EQUIPMENT FROM BUILDING 6 TO COMPLETED BUILDING 20.
WORK IN A-WING NORTH CAUSING ANY SIGNIFICANT NOISE OR DISRUPTION TO
OPERATIONAL AREAS ON FLOOR 2 SHALL BE DONE ON NIGHTS OR WEEKENDS ONLY,
OR AS COORDINATED WITH VA. WORK IN BUILDING 6 A-WING NORTH IS NOT
REQUIRED TO BE COMPLETED PRIOR TO WORK BEGINNING IN PHASE 2: BUILDING 6 C-
WING. SEE DISCIPLINE DRAWINGS FOR ADDITIONAL INFORMATION.
PHASE 2: BUILDING 6 C-WING
CONTRACTOR SHALL ERECT TEMPORARY CONSTRUCTION BARRIERS AND BEGIN
WORK IN BUILDING 6 C-WING UPON ACCEPTANCE OF PHASE 1 BUILDNG 20 WORK AND
(3) WEEK ALLOWANCE FOR MOVING FURNITURE AND EQUIPMENT.
WORK IN CORRIDOR CONNECTING WINGS A AND C, AND IN WING B, SHALL BE DIVIDED
INTO SUB-PHASES (2i-2vii) TO BE COMPLETED ON NIGHTS AND WEEKENDS SUCH THAT
STAFF AND VISITORS MAY CONTINUE TO ACCESS SPACES WITHIN THE BUILDING
WHICH ARE CONTINUING TO OPERATE DURING CONSTRUCTION. THE ELEVATORS IN
WINGS A AND C SHALL ALSO BE MADE AVAILABLE TO VA STAFF AND VISITORS AT ALL
TIMES EXCEPT AS COORDINATED WITH VA.
*NOTE: HAZARDOUS MATERIAL ABATEMENT IN CORRIDOR, DURING EACH SUB-PHASE,
MUST BE COMPLETED IN ENTIRETY BEFORE AREA MAY BE USED BY STAFF AND
VISITORS. THIS WORK MUST BE SCHEDULED WITH THE VA.
WORK SHALL BE SCHEDULED SUCH THAT WORK IN WING A IS PRIORITIZED OVER
WORK IN WING C. WORK IN WING C MAY OCCUR SIMULTANEOUSLY WITH WING A AS
LONG AS WING C WORK DOES NOT NEGATIVELY EFFECT THE SCHEDULING OF WORK
IN WING A. THE PROGRAM IN WING A WILL BE NEEDED BEFORE THE PROGRAM IN
WING C.
SEE PHASING DIAGRAMS FOR ADDITIONAL INFORMATION.
SEE DEMOLITION AND ARCHITECTURAL PLANS FOR SCHEMATIC TEMPORARY
CONSTRUCTION BARRIERS.
PHASE 3: BUILDING 6 A-WING PORCH
COORDINATE WITH VA REGARDING SCHEDULING OF THIS WORK. PHASE 3 WORK IS
NOT CONTINGENT ON ANY OTHER PHASE.
CONSTRUCTION PHASING NOTES
A
SOUTH
B D
SHADE INDICATES AREA
NOT IN SCOPE, TYP.
C SOUTH
C
NORTHA
NORTH
B D
A
SOUTH
C
NORTH
A
NORTH
A
SOUTH
B D
C SOUTH
C
NORTH
A
NORTH
D
HATCH INDICATES
ROOF AREA, NIC.
C SOUTH
C
NORTH
(ROOF
ONLY)
NO SHADE INDICATES
LOCATION OF PROJECT, TYP.
B A
SE
M
EN
T
C SOUTH
FI
R
ST
F
LO
O
R
SE
C O
N D
F
LO
O R
TH
IR
D F
LO
O
R
SHADE INDICATES
AREA NOT IN
SCOPE, TYP.
NO SHADE INDICATES
LOCATION OF PROJECT, TYP.
NO SHADE INDICATES
LOCATION OF PROJECT, TYP.
CONNECTING CORRIDOR TO BE
DIVIDED INTO MINIMUM 7 SUB-
PHASES (2i-2vii) SUCH THAT
STAFF AND VISITORS MAY
ACCESS OPERATIONAL AREAS.
i ii iii iv v
ENTRY
POINT
ENTRY POINTS
PHASE 3: ALL
DEMOLITION AND NEW
WORK AT A-WING PORCH.
A-WING NORTH WORK: ANY
WORK CAUSING NOISE OR
DISRUPTION TO OPERATIONAL
AREAS ON FLOOR 2 SHALL BE
DONE ON NIGHTS AND
WEEKENDS ONLY, OR AS
COORDINATED WITH VA.
BUILDING 6 KEY PLANS
vi vii
CONTINUOUS FIRESAFE SEALANT
TOP AND BOTTOM, & BOTH SIDES
3 1/2" SOUND ATTENUATION BATT.
5/8" TYPE X GYPSUM BOARD, BOTH SIDES
3 5/8" METAL STUD @ 16" O.C. WITH
RUNNER CHANNELS ALONG TOP
AND BOTTOM
CONSTRUCTION
SIDE
PUBLIC
SIDE
6 MIL. FIRE RETARDANT VISQUEEN
MEMBRANE. CONTINUOUSLY ADHERE
TO THE STRUCTURAL DECK ABOVE AND
TO THE FLOOR BELOW WITH TAPE.
UNDERSIDE OF STRUCTURAL DECK
UL LISTING: U465
COORDINATE WITH EXISTING CEILING
TEMPORARY IC BARRIER WALL
CONSTRUCTION (DUST WALL)
5/8" TYPE X GYP BD
3 5/8" STEEL STUDS @ 16" O.C.
BEAD OF CONT. SEALANT
6-MIL FIRE RETARDENT POLY INTERIOR SIDE
CEILING
2" DEEP LEG 3 5/8" STEEL SLIP TRACK
3 5/8" STEEL STUD TRACK
6" M
IN
CONTINUOUSLY ADHERE 6-MIL. FIRE
RETARDANT POLY TO DECK WITH TAPE
CONTINUOUSLY ADHERE FIRE RETARDENT
POLY TO FLOOR WITH TAPE
EXISTING DECK
CONSTRUCTION
SIDE
OCCUPIED
SIDE
PUBLIC
SIDE
1 HOUR FIRE RATED METAL DOOR ASSEMBLY
AND FRAME WITH SEALS, CARD READER,
HARDWARE AND CLOSER
ROOM PRESSURE MONITOR
HAND SANITIZER
SEAL ALL EDGES WITH TAPE
SEAL ALL EDGES WITH TAPE
REFER TO TEMPORARY BARRIER TYPE FOR
REQUIRED CONDITION TO STRUCTURE ABOVE
VA / OSHA TEMPORARY SIGNAGE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C
U s e rs \c s u tt o n \D o c u m e n ts
\1
.1
.2
A v c s u tt o n B
F V
.r v t
/1 /2
:0
:3
A
M
GC101
INFECTION CONTROL /
CONSTRUCTION LOGISTICS PLANGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1 1/2" = 1'-0"GC101
1 TEMPORARY 1 HR FIRE RATED SMOKE BARRIER WALL CONSTRUCTION NFPA 241
SCALE: 1 1/2" = 1'-0"GC101
2 TEMPORARY INFECTION CONTROL BARRIER WALL CONSTRUCTION
SCALE: 1/4" = 1'-0"GC101
3 TEMPORARY WALL CONSTRUCTION ELEVATION
PHASE 2: BUILDING 6 WORK
EXCEPT FOR A-WING NORTH -
SEE DIAGRAMS THIS SHEET
FOR ADDITIONAL INFORMATION
PHASE 1:
BUILDING 6 A-WING NORTH
and
BUILDING 20 THIRD FLOOR (SEE DISCIPLINE
DRAWINGS FOR ADDITIONAL INFORMATION)
PHASE 3: BUILDING 6 PORCH
*PRINT THIS SHEET IN COLOR FOR LEGIBILITY*
DN
STAIR
B -W
IN
G
C -W
IN
G
C -W
IN
G
D -W
IN
G
WAREHOUSE
TEMPORARY
CB23
CB17
ELECTRICAL
CB16
STROAGE
CB15
CB18
ABANDONED
CB19
ELEV.
EQUIP.
CB20
STAIR
C2
ABANDONED
REFRIG./FREEZER
UTILITY
CB21
ABANDONED
REFRIG./FREEZER
VESTIBULE
CB22
STORAGE
CORRIDOR
ELEV.
C2
A
SOUTH
B D
BUILDING 6 BASEMENT KEY PLAN
N
SHADE INDICATES
AREA NOT IN
SCOPE, TYP
NO SHADE INDICATES
LOCATION OF PROJECT,
TYP
C
SOUTH
C
NORTH
A
NORTH
#HAZMAT ABATEMENT NOTES
1. REMOVE APPROXIMATELY 4,640 SF OF BLACK MASTIC ASSOCIATED WITH
12"X12" WHITE/GRAY FLOOR TILE IN BUILDING 6. NOTE: ALSO REMOVE AND
ABATE SIMILAR MATERIAL THROUGHOUT THE FIRST FLOOR CORRIDOR
FROM WINGS B THROUGH D. THIS REPRESENTS APPROXIMATELY 3,500
ADDITIONAL SF. THIS AREA NOT REPRESENTED IN HAZARDOUS MATERIAL
ABATEMENT REPORT.
2. REMOVE APPROXIMATELY 5,700 SF OF FIBER BOARD WITH TAR PAPER IN
BUILDING 6 A-WING NORTH.
3. REMOVE APPROXIMATELY 5,700 SF EACH OF 9"X9" WHITE/GRAY
CHECKERBOARD PATTERN FLOOR TILE AND ASSOCIATED BLACK MASTIC IN
BUILDING 6.
4. REMOVE APPROXIMATELY 32 LF OF DOOR FRAME CAULK IN BUILDING 20.
NO ABATEMENT ANTICIPATED IN AREAS NOT SHOWN.
REFERS TO ALL HA SHEETS. NOT ALL NOTES USED ON ALL SHEETS.
6947 SF
STORAGE
C147
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C
U s e rs \c s u tt o n \D o c u m e n ts
\1
.1
.2
A v c s u tt o n B
F V
.r v t
/1 /2
:0
:5
A
M
HA100
HAZMAT. ABATEMENT BUILDING
20 AND 6 BASEMENT PLANGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"HA100
1 BASEMENT - C WING NORTH - HAZMAT ABATEMENT
N
SCALE: 1/8" = 1'-0"HA100
2 BUILDING 20 - HAZMAT PLAN
N
DN
DN
UP
UP
DN
DN
DN
CEMETERY SCHED. OFFICE
C113
HAC
C109
C108
C107 C106
C105
C104
C103
LACTATION
VENDING
HAC
B109
B108
B103HAC
MENS WOMENS
HAC
FILES/SCANNING
A115
CONFERENCE
A114
MECHANICAL
LEAN TRAINING CENTER
A116
MECHANICAL
HOME BASED PRIMARY CARE
KITCHENETTEHAC
STAIR
STAIR
STAIR
STAIR
A -W
IN
G
B -W
IN
G
B -W
IN
G
WOMEN
RESTROOM
ELEVATOR
C -W
IN
G
C -W
IN
G
D -W
IN
G
806 SF
CORRIDOR
B/C
858 SF
CORRIDOR
A/B
CORRIDOR CORRIDOR
CORRIDOR
COMPUTER ROOM
A123
STORAGE
A124
A104
MEN
RESTROOM
VESTIBULE
STAIR
WOMENS
TOILET
MENS
TOILET
OIT
SUPPORT
A106
A117
A111
ELEVATOR
#HAZMAT ABATEMENT NOTES
1. REMOVE APPROXIMATELY 4,640 SF OF BLACK MASTIC ASSOCIATED WITH
12"X12" WHITE/GRAY FLOOR TILE IN BUILDING 6. NOTE: ALSO REMOVE AND
ABATE SIMILAR MATERIAL THROUGHOUT THE FIRST FLOOR CORRIDOR
FROM WINGS B THROUGH D. THIS REPRESENTS APPROXIMATELY 3,500
ADDITIONAL SF. THIS AREA NOT REPRESENTED IN HAZARDOUS MATERIAL
ABATEMENT REPORT.
2. REMOVE APPROXIMATELY 5,700 SF OF FIBER BOARD WITH TAR PAPER IN
BUILDING 6 A-WING NORTH.
3. REMOVE APPROXIMATELY 5,700 SF EACH OF 9"X9" WHITE/GRAY
CHECKERBOARD PATTERN FLOOR TILE AND ASSOCIATED BLACK MASTIC IN
BUILDING 6.
4. REMOVE APPROXIMATELY 32 LF OF DOOR FRAME CAULK IN BUILDING 20.
NO ABATEMENT ANTICIPATED IN AREAS NOT SHOWN.
REFERS TO ALL HA SHEETS. NOT ALL NOTES USED ON ALL SHEETS.
OFFICE
C207
OFFICE
C208
OFFICE
C209
OFFICE
C204
OFFICE
C203
OFFICE
C202
STORAGE
C212STAIR
C201
170 SF
STAIR
C205 1
ELEVATOR
C307
C302
C305
C304
C303
STAIR
C306 C308
C301
ELEV.
C1
CORRIDOR
C3A
RESTROOM
OFFICE OFFICE
OFFICE
OFFICE
OFFICEOFFICE
OFFICE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
BID DOCUMENTS 11/12/2021
C
U s e rs \c s u tt o n \D o c u m e n ts
\1
.1
.2
A v c s u tt o n B
F V
.r v t
/1 /2
:2
:0
P
M
HA101
HAZMAT. ABATEMENT 1ST, 2ND,
AND 3RD FLOOR PLANGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021 JF CS
BID DOCUMENTS
FULLY SPRINKLERED
SCALE: 1/8" = 1'-0"HA101
1 FIRST FLOOR - A-WING - HAZMAT ABATEMENT
SCALE: 1/8" = 1'-0"HA101
2 SECOND FLOOR - C-WING - DEMOLITION PLAN
SCALE: 1/8" = 1'-0"HA101
3 THIRD FLOOR - C-WING - HAZMAT PLAN
NN
CIVIL GENERAL NOTES
CI001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-C
IV
IL
G
EN
ER
AL
N O
TE
S.
dw g
SCALE: 1" = 10'
0' 5' 10' 20'
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-D
EM
O
LI
TI
O N
P
LA
N .d w g
SITE DEMOLITION PLAN
CD101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-D
EM
O
LI
TI
O N
P
LA
N .d w
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-D
EM
O
LI
TI
O N
P
LA
N .d w g
SITE DEMOLITION PLAN
CD102
0' 10' 20'
IP
IP
IP
IP
IP
IP
SCALE: 1" = 10'
0' 5' 10' 20'
N
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-S
IT
E
PL
AN
.d w g
SITE LAYOUT PLAN
CS101
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-S
IT
E
PL
AN
.d w
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-S
IT
E
PL
AN
.d w g
SITE LAYOUT PLAN
CS102
SCALE: 1" = 10'
0' 10' 20'
0' 10' 20'
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
-S
IT
E
D
ET
AI
LS
.d w g
CS501
SITE DETAILS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
G
R
AD
IN
G
A N
D U
TI
LI
TY
P
LA
N
.d w g
SCALE: 1" = 10'
0' 5' 10' 20'
N
GRADING AND UTILITY PLAN
CG101
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5000 West National Avenue, Milwaukee, WI 53295
695-21-703
11/12/2021
BID DOCUMENTS
FULLY SPRINKLERED
Revisions: Date: CMB KSN
P:
\1
6.
VA
M ilw au ke e
- A E
ID
IQ
-2 \T as k
EH
R
M A dm in
T ra in in g
Sp ac e\ 2.
D ra w in gs \2
-2 _C iv il\
.1
6.
G
R
AD
IN
G
A N
D U
TI
LI
TY
P
LA
N
.d w g
N
SCALE: 1" = 10'
0' 10' 20'
GRADING AND UTILITY PLAN
CG102
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\l la i\ D o c u m e n ts
\1
.1
.2
S tr u c t_ v lla i@ g u id o n d e s ig n .c o m
.r v t
/1 /2
:4
:3
A M
SI001
STRUCTURAL GENERAL NOTES
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
EHRM TRAINING AND ADMIN
SPACE SUPPORT
5100 West National Avenue
695-21-703
11/12/2021 JF LKL
BID DOCUMENTS
FULLY SPRINKLERED
GENERAL
THE STRUCTURE HAS BEEN DESIGNED FOR THE IN-SERVICE LOADS ONLY. THE METHODS, MEANS, PROCEDURES, AND SEQUENCES OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE CONTRACTOR. THE STRUCTURE IS DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND SEQUENCE TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE ADDITION OF
NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, TIEDOWNS, ETC.
THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING
DRAWINGS AND SPECIFICATIONS.
THE GENERAL NOTES ON THE DRAWINGS ARE TO BE USED IN CONJUNCTION WITH THE FULL WRITTEN MATERIAL SPECIFICATIONS (IF ANY) FOR THE PROJECT. IF A DISCREPANCY OCCURS BETWEEN THE NOTES AND THE FULL SPECIFICATIONS, THE MORE STRINGENT
REQUIREMENT SHALL APPLY.
NO PENETRATIONS THROUGH STRUCTURAL ELEMENTS, OTHER THAN THOSE SHOWN ON THE DRAWINGS, SHALL BE MADE WITHOUT
THE APPROVAL OF THE STRUCTURAL ENGINEER.
CONTRACTOR TO COORDINATE ALL EQUIPMENT, ROOF DRAINS, CHASES, AND OTHER ITEMS CONNECTED TO THE STRUCTURE BEFORE
FABRICATION BEGINS.
CONCRETE MIX DESIGN SUBMITTAL
THE CONTRACTOR SHALL SUBMIT FOR THE REVIEW OF THE STRUCTURAL ENGINEER A MIX DESIGN FOR EACH PROPOSED CLASS OF CONCRETE. EACH MIX DESIGN SHALL BE IDENTIFIED BY A MIX NUMBER OR OTHER UNIQUE IDENTIFICATION. THE CONTRACTOR SHALL NOT VARY FROM THE MIX DESIGNS NOR USE ANY CONCRETEOTHER THAN THE APPROVED MIX DESIGNS WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. MIX DESIGN SUBMITTALS SHALL INCLUDE THE FOLLOWING INFORMATION:
1. MIX DESIGN NUMBER OR UNIQUE IDENTIFICATION AND INTENDED LOCATION OF PLACEMENT.
2. CEMENT TYPE, PROPORTION AND NAME OF MANUFACTURER.
3. FLY ASH PROPORTION (WHEN USED), LABORATORY ANALYSIS CERTIFICATION, AND NAME AND LOCATION OF SUPPLIER.
4. COURSE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
5. FINE AGGREGATE PROPORTION, GRADATION REPORT, NAME AND LOCATION OF SUPPLIER.
6. MIXING WATER PROPORTION AND SOURCE.
7. ADMIXTURE DOSAGES, PRODUCT NAME(S) AND MANUFACTURER NAME(S).
8. FIBER REINFORCEMENT DOSAGE (WHEN USED), PRODUCT NAME AND MANUFACTURER NAME.
9. DESIGN 28-DAY COMPRESSIVE STRENGTH (F'C).
10. DESIGN SLUMP RANGE.
11. DESIGN AIR-ENTRAINMENT (FOR CONCRETE REQUIRING ENTRAINED AIR).
12. STATISTICAL ANALYSIS OF LABORATORY STRENGTH TEST DATA IN ACCORDANCE WITH "STANDARD DEVIATION"
DETERMINATION OUTLINED IN ACI 318.
SHOP DRAWING SUBMITTALS
THE CONTRACTOR SHALL PREPARE DETAILED SHOP DRAWINGS TO ENABLE HIM TO FABRICATE, ERECT AND CONSTRUCT ALL PARTS OF THE WORK IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS. THESE SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT ONLY. THE CONTRACTOR IS RESPONSIBLE FOR ALL DIMENSIONS, ACCURACY AND FIT OF WORK.
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO THE STRUCTURAL ENGINEER. DRAWINGS
SUBMITTED WITHOUT CONTRACTOR'S REVIEW WILL BE RETURNED UNCHECKED.
SUBMIT ELECTRONIC VERSIONS OF SHOP DRAWINGS. SUBMIT SHOP DRAWINGS IN PDF FORMAT.
SUBMIT SHOP DRAWINGS FOR EACH OF THE FOLLOWING ITEMS:
1. CONCRETE REINFORCEMENT
2. CONCRETE MASONRY REINFORCEMENT
3. STRUCTURAL STEEL (INCLUDING DESIGN CALCULATIONS SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE
WHERE THE PROJECT IS CONSTRUCTED FOR ALL CONNECTIONS NOT SPECIFICALLY DETAILED ON THE DRAWINGS)
4. STEEL DECK
PRODUCT DATA SUBMITTALS
THE CONTRACTOR SHALL SUBMIT FOR APPROVAL PRODUCT DATA FOR THE SPECIFIC ITEMS LISTED BELOW. CONTRACTOR SHALL NOT USE PRODUCTS OTHER THAN THOSE SUBMITTED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.
MANUFACTURER'S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES, AND PATTERNS AS A BASIS OF DESIGN. PRODUCTS OF AUTHORIZED EQUAL MANUFACTURER'S EQUIVALENT TO COLORS, FINISHES, TEXTURES, AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS IN EVERY RESPECT MAY BE ACCEPTABLE WITH SUBMITTAL OF A COMPLETED SUBSTITUTION REQUEST CONTAINING ALL PRODUCT DATA, TESTING AND ACTUAL
SAMPLES, AND UPON APPROVAL IN WRITING BY CONTRACTING OFFICER.
SUBMIT ELECTRONIC VERSIONS OF PRODUCT DATA IN PDF FORMAT TO THE STRUCTURAL ENGINEER AND COR FOR REVIEW.
1. FIBER REINFORCEMENT FOR CONCRETE
2. CONCRETE REINFORCEMENT
3. DIAMOND PLATE DOWELS FOR SLABS ON GRADE
4. CONCRETE CURING COMPOUND
5. CONCRETE JOINT SEALANT
6. WATER STOPS
7. MASONRY JOINT REINFORCEMENT
8. EXPANSION ANCHORS
9. ADHESIVE ANCHORS
10. NON-SHRINK GROUT
11. COLD FORMED METAL STUDS (EXTERIOR ONLY)
BELOW-GRADE WALLS
DO NOT BACKFILL AGAINST BELOW-GRADE CONCRETE (OR MASONRY) WALLS UNTIL THE CONCRETE (OR MASONRY ASSEMBLAGE) HAS
REACHED ITS 28-DAY COMPRESSIVE STRENGTH.
WHERE BACKFILL IS REQUIRED ON BOTH SIDES OF BELOW-GRADE WALLS, BACKFILL EVENLY ON EACH SIDE OF EACH WALL TO
PREVENT UNBALANCED SOIL LOADS AGAINST THE WALL.
UNLESS NOTED OTHERWISE, DO NOT BACKFILL AGAINST BASEMENT WALLS UNTIL THE BASEMENT AND GROUND FLOOR SLABS HAVE BEEN COMPLETELY INSTALLED AND REACHED THEIR 28-DAY COMPRESSIVE STRENGTH AND ALL FLOOR FRAMING AND SLAB
CONNECTIONS TO THE BASEMENT WALLS HAVE BEEN COMPLETELY INSTALLED.
WHERE BASEMENT WALLS OCCUR, BACKFILL EVENLY ON ALL SIDES OF THE BUILDING TO PREVENT UNBALANCED SOIL LOADS AGAINST
THE BASEMENT STRUCTURE, UNLESS NOTED OTHERWISE.
CONCRETE
REINFORCED CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE (ACI 318) AND COMMENTARY (ACI 318R).
MIXING, TRANSPORTING, AND PLACING OF CONCRETE SHALL CONFORM TO THE LATEST EDITION OF THE SPECIFICATIONS FOR STRUCTURAL CONCRETE (ACI 301). READY-MIXED CONCRETE SHALL CONFORM TO THE REQUIREMENTS OF ASTM C94. IN CASE OF A
DISCREPANCY, THE PLANS AND SPECIFICATIONS SHALL GOVERN.
CEMENT SHALL CONFORM TO ASTM C150, TYPE I, UNO.
FLY ASH SHALL CONFORM TO ASTM C618, CLASS C OR F. THE RATIO OF THE AMOUNT (BY WEIGHT) OF FLY ASH TO TOTAL
CEMENTITIOUS MATERIALS IN THE MIX SHALL NOT EXCEED 25 PERCENT.
NORMAL WEIGHT AGGREGATES SHALL CONFORM TO ASTM C33.
WATER-REDUCING ADMIXTURES SHALL CONFORM TO ASTM C494.
AIR-ENTRAINING ADMIXTURES SHALL CONFORM TO ASTM C260 AND SHALL BE CERTIFIED BY THE MANUFACTURER TO BE COMPATIBLE
WITH OTHER ADMIXTURES.
CALCIUM CHLORIDE ADMIXTURES OR ADMIXTURES CONTAINING MORE THAN 0.1 PERCENT CHLORIDE IONS SHALL NOT BE USED.
IN COLD WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 306R, COLD WEATHER CONCRETING.
IN HOT WEATHER CONDITIONS, MIXING, PLACING, FINISHING, CURING AND PROTECTION OF CONCRETE SHALL BE PERFORMED IN
ACCORDANCE WITH THE LATEST EDITION OF ACI 305R, HOT WEATHER CONCRETING.
USE OF CONSTRUCTION JOINTS AT LOCATIONS OTHER THAN THOSE INDICATED ON THE DRAWINGS SHALL BE SUBMITTED TO THE
STRUCTURAL ENGINEER FOR REVIEW.
SLUMP FOR PUMPED CONCRETE SHALL BE MEASURED AT POINT OF DISCHARGE.
NORMAL WEIGHT CONCRETE SHALL BE USED IN THE FOLLOWING AREAS AND SHALL
HAVE THE PROPERTIES AS SHOWN BELOW:
PROJECT CONCRETE
1. COMPRESSIVE STRENGTH (28 DAYS): 4000 PSI
2. MAXIMUM SLUMP: 4 INCHES
3. MINIMUM CEMENTITIOUS MATERIALS CONTENT: 470 LB./CU. YD. (USE TYPE II SULFATE RESISTANT CEMENT)
4. MAXIMUM SLUMP FOR CONCRETE CONTAINING HIGH-RANGE WATER-REDUCING ADMIXTURE: 8 INCHES (AFTER ADMIXTURE IS
ADDED TO CONCRETE WITH 2 TO 4 INCH SLUMP).
5. MAXIMUM WATER/CEMENTITIOUS MATERIALS RATIO: 0.48
6. MAXIMUM COARSE AGGREGATE SIZE: 1 INCH
7. AIR CONTENT: N/A
SHORING/RE-SHORING
THE SHORING AND/OR RE-SHORING DESIGN FOR CONCRETE FRAME SYSTEMS IS THE RESPONSIBILITY OF THE CONTRACTOR.
TEMPORARY SHORING FOR SLABS, BEAMS, AND GIRDERS SHALL BE ADEQUATE TO CARRY THE TOTAL WEIGHT OF THE SLAB-BEAM- GIRDER SYSTEM AND ANY TEMPORARY CONSTRUCTION LOADS TO BE IMPOSED ON THE STRUCTURAL SYSTEM. SHORING FOR A LEVEL SHALL NOT BE REMOVED UNTIL THE CONCRETE AT THAT LEVEL HAS ATTAINED THE SPECIFIED COMPRESSIVE STRENGTH (F'C).
REMOVAL OF SHORING AND/OR RESHORING SHALL NOT CAUSE OVERSTRESSING OF ANY STRUCTURAL ELEMENTS.
REINFORCING STEEL
REINFORCING STEEL SHALL BE DEFORMED BARS CONFORMING TO ASTM A615 AND SHALL HAVE A MINIMUM YIELD STRENGTH OF 60,000
PSI.
REINFORCING BAR DETAILING, FABRICATING, AND PLACING SHALL CONFORM TO THE LATEST EDITION OF THE FOLLOWING STANDARDS:
ACI 301, ACI 315, ACI 318 AND ACI DETAILING MANUAL (SP66).
UNLESS A GREATER AMOUNT OF COVER IS INDICATED ON THE DRAWINGS, PROVIDE THE FOLLOWING MINIMUM CONCRETE COVER
OVER REINFORCEMENT AS FOLLOWS:
CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH: 3 INCHES
#6 BARS AND LARGER EXPOSED TO EARTH OR WEATHER: 2 INCHES
#5 BARS AND SMALLER EXPOSED TO EARTH OR WEATHER: 1-1/2 INCHES
BEAM AND COLUMN TIES, STIRRUPS AND SPIRALS: 1-1/2 INCHES
ELEVATED SLAB BARS NOT EXPOSED TO EARTH OR WEATHER: 3/4 INCH
REINFORCING STEEL SHALL NOT BE TACK WELDED, WELDED, HEATED OR CUT UNLESS INDICATED ON THE CONTRACT DOCUMENTS OR
APPROVED BY THE STRUCTURAL ENGINEER.
WHERE LAP SPLICE LENGTHS ARE NOT SHOWN OR NOTED, PROVIDE A CLASS "B" LAP.
ALL 90 DEGREE AND 180 DEGREE BENDS SHOWN ON THE DRAWINGS SHALL BE STANDARD HOOKS, UNLESS NOTED OTHERWISE.
PROVIDE CORNER BARS OF SAME SIZE AND SPACING AS HORIZONTAL BARS AT CORNERS OF ALL WALLS AND GRADE BEAMS. LAP
SPLICE CORNER BARS WITH STRAIGHT BARS.
UNLESS OTHERWISE SHOWN OR NOTED, PROVIDE 2-#5 BARS (ONE EACH FACE) AROUND UNFRAMED OPENINGS IN CONCRETE WALLS AND GRADE BEAMS. PLACE BARS PARALLEL TO THE SIDES OF THE OPENING AND EXTEND 24" BEYOND CORNERS.
CONCRETE TESTING
MAKE ONE SET OF TEST CYLINDERS IN ACCORDANCE WITH ASTM C31 FOR EACH DAY'S POUR AND FOR EACH 100 CUBIC YARDS. EACH SET SHALL INCLUDE ONE SPECIMEN TESTED AT 7 DAYS, 2 SPECIMENS TESTED AT 28 DAYS AND ONE SPECIMEN RETAINED IN RESERVE TO BE TESTED AT THE DIRECTION OF THE STRUCTURAL ENGINEER. SPARE CYLINDER MAY BE DISCARDED 90 DAYS AFTER CASTING
UNLESS
DIRECTED OTHERWISE BY THE STRUCTURAL ENGINEER. THIS SET OF TEST CYLINDERS SHALL BE PROTECTED AGAINST FREEZING.
WHEN THE AMBIENT TEMPERATURE IS EXPECTED TO FALL BELOW 40 DEGREES DURING THE COURSE OF A CONCRETE POUR OR SUBSEQUENT CURING PROCESS, AN ADDITIONAL SET OF CONCRETE TEST CYLINDERS SHALL BE MADE AND TESTED. THESE CYLINDERS SHALL BE STORED IMMEDIATELY ADJACENT TO, AND CURED UNDER THE SAME CONDITIONS AS THE BUILDING CONCRETE. SPECIAL
CURING BOXES ARE NOT PERMITTED FOR THESE TEST CYLINDERS.
FORWARD COPIES OF TEST RESULTS TO THE ARCHITECT, STRUCTURAL ENGINEER, READY-MIX SUPPLIER AND CONTRACTOR WITHIN 24
HOURS AFTER TESTING.
MASONRY
CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE LATEST EDITION OF THE BUILDING CODE REQUIREMENTS FOR
CONCRETE MASONRY STRUCTURES (ACI 530).
CONCRETE MASONRY SHALL CONSIST OF HOLLOW UNITS CONFORMING TO THE REQUIREMENTS OF ASTM C90, WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1900 PSI. CONCRETE MASONRY ASSEMBLAGES SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH
(F'M) OF 1,500 PSI AT 28 DAYS.
MORTAR SHALL BE TYPE S PROPORTIONED IN ACCORDANCE WITH ASTM C270.
GROUT FOR REINFORCED MASONRY SHALL BE PROPORTIONED IN ACCORDANCE WITH ASTM C476. COARSE AND FINE AGGREGATES SHALL CONFORM TO ASTM C404. USE COARSE GROUT FOR ALL GROUTING EXCEPT HIGH-LIFT POURS DEFINED BY ACI 530, WHERE FINE
GROUT SHALL BE USED.
PROVIDE 9-GAUGE GALVANIZED STEEL WIRE JOINT REINFORCEMENT IN ALL MASONRY CONSTRUCTION. REINFORCEMENT SHALL BE CONTINUOUS AND BE LAPPED EIGHT INCHES AT SPLICES. CUT REINFORCEMENT AT ALL CONTROL AND EXPANSION JOINTS. SPACE REINFORCEMENT AT 8" ON CENTER FOR PARAPETS AND BELOW GROUND FLOOR ELEVATION. ELSEWHERE SPACE REINFORCEMENT AT
16 INCHES ON CENTER.
BEAMS AND LINTELS SHALL BEAR A MINIMUM OF 8 INCHES ONTO SUPPORTING MASONRY, UNLESS NOTED OTHERWISE. BEARING FOR ALL BEAMS, LINTELS, JOISTS, ETC. SHALL BE GROUTED SOLID A MINIMUM OF ONE COURSE (8 INCHES) BELOW BEARING ELEVATION, UNLESS NOTED OTHERWISE.
EXPANSION ANCHORS
EXPANSION ANCHORS SHALL BE CARBON STEEL ANCHORS AS MANUFACTURED BY HILTI FASTENING SYSTEMS OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER AND SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
EXPANSION ANCHORS SHALL NOT BE INSTALLED IN CONCRETE UNTIL IT HAS ATTAINED ITS SPECIFIED MINIMUM 28 DAY COMPRESSIVE
STRENGTH.
ADHESIVE ANCHORS
ADHESIVE ANCHORS SHALL BE HILTI "HIT HY200" FOR SOLID SUBSTRATE AND HILTI "HIT HY270" FOR HOLLOW SUBSTRATE OR AN EQUIVALENT SUBSTITUTE APPROVED BY THE STRUCTURAL ENGINEER, UNLESS NOTED OTHERWISE ON PLANS. ANCHORS SHALL BE INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS BY INSTALLERS TRAINED BY THE MANUFACTURER'S
REPRESENTATIVE.
MINIMUM EMBEDMENT DEPTH SHALL BE 8 BOLT DIAMETERS UNLESS NOTED OTHERWISE.
NON-SHRINK GROUT
GROUT SHALL BE A NON-METALLIC, SHRINKAGE RESISTANT (WHEN TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ASTM C827 OR CRD-C621), PREMIXED, NON-CORROSIVE, NON-STAINING PRODUCT CONTAINING PORTLAND CEMENT, SILICA SANDS, SHRINKAGE COMPENSATING AGENTS AND FLUIDITY IMPROVING COMPOUNDS. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH (F'C) OF
5,000 PSI IN 28 DAYS.
WATERSTOPS
SELF-EXPANDING STRIP WATER STOPS SHALL BE VOLCLAY WATERSTOP-RX 101 UNLESS NOTED OTHERWISE. INSTALL IN ACCORDANCE
WITH MANUFACTURER'S WRITTEN INSTRUCTIONS.
STRUCTURAL STEEL
STRUCTURAL STEEL DETAILING, FABRICATION AND ERECTION SHALL CONFORM TO THE ANSI/AISC 360 SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, LATEST EDITION WITH AMENDMENTS, AND THE AISC 303 CODE OF STANDARD PRACTICE FOR
STEEL BUILDINGS AND BRIDGES, LATEST EDITION WITH AMENDMENTS.
STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, 50 KSI.
STRUCTURAL STEEL PLATES AND ROLLED SHAPES OTHER THAN WIDE-FLANGE SHAPES SHALL CONFORM TO ASTM A36, UNLESS NOTED
OTHERWISE.
STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
STRUCTURAL PIPE SHALL CONFORM TO ASTM A53, GRADE B.
ANCHOR RODS SHALL CONFORM TO ASTM F1554, GRADE 36, UNLESS NOTED OTHERWISE.
STEEL STUDS SHALL CONFORM TO ASTM A108.
BOLTED CONNECTIONS SHALL CONFORM TO THE SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS, APPROVED BY THE RESEARCH COUNCIL ON STRUCTURAL CONNECTIONS OF THE ENGINEERING FOUNDATION. BOLTED CONNECTIONS FOR STRUCTURAL STEEL MEMBERS SHALL BE MADE WITH 3/4" DIAMETER A325 BOLTS, UNLESS NOTED OTHERWISE.
BOLTED CONNECTIONS SHALL BE TIGHTENED TO THE SNUG TIGHT CONDITION, EXCEPT BOLTED CONNECTIONS IN BRACE ELEMENTS
ARE TO BE FULLY PRETENSIONED WITH CLASS A FAYING SURFACES.
WELDING PROCEDURES SHALL CONFORM TO THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING
CODE FOR STEEL ANSI/AWS D1.1.
WELDED CONNECTIONS USING ASTM A992 STEEL AS A BASE METAL SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES.
UNLESS OTHERWISE SHOWN OR NOTED ON THE DRAWINGS, OTHER WELDED CONNECTIONS MAY BE MADE WITH STANDARD E70XX
ELECTRODES.
STRUCTURAL STEEL THAT RECEIVES FINISH PAINT SHALL BE SHOP-PRIMED WITH A RUST-INHIBITING PRIMER, UNLESS NOTED OTHERWISE ON THE DRAWINGS. CONTRACTOR SHALL VERIFY PRIMER IS COMPATIBLE WITH FINISH COAT SYSTEM SPECIFIED BY THE
ARCHITECT. COORDINATE FINISH PAINTING REQUIREMENTS WITH THE ARCHITECT.
STRUCTURAL STEEL THAT IS NOT EXPOSED IN THE FINISHED CONSTRUCTION AND DOES NOT RECEIVE FINISH PAINT SHALL NOT BE
SHOP-PRIMED, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
STRUCTURAL STEEL NOTED TO BE GALVANIZED SHALL BE HOT-DIP GALVANIZED IN CONFORMANCE WITH ASTM A123.
DO NOT PAINT OR GALVANIZE THE FOLLOWING SURFACES:
1. SURFACES TO BE WELDED.
2. SURFACES TO RECEIVE BOLTED SLIP-CRITICAL CONNECTIONS.
3. SURFACES TO RECEIVE SHEAR STUD CONNECTIONS.
4. SURFACES TO RECEIVE SPRAYED-ON FIREPROOFING.
ALL ABRASIONS TO GALVANIZED SURFACES OR SURFACES TO RECEIVE AN ARCHITECTURAL FINISH COAT SHALL BE TOUCHED-UP AFTER ERECTION IS COMPLETE. FOR PAINTED STEEL, USE A PRIMER EQUIVALENT TO THE SHOP PAINT. FOR GALVANIZED STEEL, USE
A ZINC-RICH COLD-GALVANIZING PAINT.
DESIGN CONNECTIONS NOT SHOWN IN ACCORDANCE WITH THE ASD SPECIFICATION AND MANUAL OF STEEL CONSTRUCTION. UNLESS NOTED OTHERWISE ON THE DRAWINGS, DESIGN BEAM CONNECTIONS NOT SHOWN, TO SUPPORT A MINIMUM OF A 10 KIP SHEAR REACTION. PROVIDE NO LESS THAN 2 BOLTS IN ANY SINGLE LINE OF BOLTS, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
PROVIDE L4X4X1/4 FRAMED OPENINGS FOR ALL ROOF PENETRATIONS 12 INCHES OR LARGER ALONG ANY SIDE, UNLESS LARGER FRAMING IS INDICATED. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR PENETRATIONS.