Attachment 3b-MMAC-BMB Type B-Final IFC Drawings-VOLUME 1-R1 pages 26thru45.pdf
PDF 10 MB Posted
- Attached to
- MMAC Base Maintenance Renovation Federal contract opportunity
- Solicitation number
- 6973GH-20-R-00062
About this file
This solicitation seeks proposals for the renovation of the Base Maintenance Building at the Mike Monroney Aeronautical Center in Oklahoma City. The successful offeror will provide all labor, supplies, materials, equipment, and tools to complete upgrades in accordance with specifications and drawings. Renovations include pavement, sidewalks, utility connections, grading, and interior building work. The period of performance is 270 days from Notice to Proceed. Proposals are due by 2:00 PM Central Time on February 21, 2020 and the contract award date is anticipated for March 2020. The work is being procured using full and open competition with a total contract value between $2-5 million.
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
U G
E U
G E
U G
E
U G
E U
G E
UGE
UGE UGE
U G
E U
G E
UGE
C C
C C C C C C CC C
C
C
C
UGE UGE UGE
UGE
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -1 g ra .d g n
603001530
SHEET SIZE = 22"x 34"
GRAPHIC SCALE
OKC (405) 840-5032
800-522-OKIE (6543)
SYSTEM, INC.
ONE-CALL
OKLAHOMA
TULSA (918) 732-OKIE (6543)
TO ANY EXCAVATION.
CONTACT THESE NUMBERS PRIOR
OF ALL UNDERGROUND UTILITIES.
FOR INFORMATION ON THE LOCATION
THESE NUMBERS ARE TO BE USED
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
PR
OFE
F
S
SS
S
SS
S S
SS SS SS
S S
C .O
C.O.
C .O
CP
CP
CP
F H
G V
GV
IC
V
ICV
IC
V
IC
V
IC
V
M B
S S
S S
S D
S D
S D
S D
P L
B
W V
W V
W V
W V
S D
S S
G
DENNING AVE.
S .W T
H S
T
EDDIE AVE.
W
FH
S .W T
H S
T
W
S S S SS S S S
S S
S S
S
S S
S S
S S
S
G GG
G
G G
G G
G
G
G G
W W
W W
W W
W
FO FO
F O
S S
S S
S S
S S
S S
S S
S S
SSSS
S S
S S
S S
S S
EDDIE AVE.
F H
F
W
W
W
W
W
S S S
S
SS SS SS SS SS SS SS SS
MHMH
G
G G G G
W
GV
W M
W
MH
T
MH MH
UGE
UGE UGE UGE UGE UGE UGE UGE UGE
U G
E U
G E
U G
E U
G E
U G
E
U G
E
UGE
UGE
UGE
UGE
UGE
UGE
U G
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
UGE
U G
E U
G E
U G
E
SS SS
C C
C
U G
E U
G E
U G
E U
G E
G
SS
UGE
UGE
G
G G
S S
SS
S S S S S
UGE UGE UGEUGE UGE UGE UGE UGE
U G
E
C
SS
B D
G
BDG #267
B
D G
B D
G
BDG #241
S
S
C.O.
S
S S
SS
W
W
Bollard
No Parking Sign-
No Parking Sign-
& S.W. 67th Sign- Eddie
FF=1278.88
Do Not Enter Sign-
Sign- One Way
Sign- Yield
GATE
RAMP
FL = 1276.08
INLET STRUCTURE
6" PVC PIPE, TIE TO EXIST.
STA. 1+00, BEGIN CONST.
TG = 1278.00
FL = 1275.76
INLET BOX STRUCTURE
6" PVC PIPE, INSTALL
STA. 1+63, END CONST.
C-104
GRADING PLAN
C-505
C-505
BDG #15
BDG #28
FF=1278.90
PVT = PAVEMENT
TC = TOP OF CURB
G = GUTTER
GRADING NOTES:
10. ENSURE POSTIVE DRAINAGE FROM ALL ROOFDRAIN DOWNSPOUTS
ALL ELEVATIONS ARE TO TOP OF PAVEMENT UNLESS OTHERWISE NOTED.9.
6” BELOW TOP OF SLAB/FINISHED FLOOR ELEVATION AND SLOPE AWAY AT 5% MINIMUM.
CONTRACTOR TO ENSURE LANDSCAPING/PLANTING AREAS ADJACENT TO BUILDING ARE8.
GEOTECHNICAL REPORT RECOMMENDATIONS.
ALL FILL TO BE PLACED SHALL BE IN ACCORDANCE WITH THE CURRENT APPLICABLE7.
PRIOR TO COMMENCING GRADING OPERATIONS.
REFER TO EROSION CONTROL PLAN FOR EROSION CONTROL DEVICES TO BE INSTALLED6.
IF ADA CRITERIA CANNOT BE MET AT ANY LOCATION.
DOORS SHALL BE ADA COMPLIANT. CONTRACTOR SHALL NOTIFY ENGINEER IMMEDIATELY
LONGITUDE SLOPE OR 2% CROSS SLOPE. SIDEWALK ACCESS TO EXTERNAL BUILDING
DRIVEWAYS SHALL CONFIRM TO ADA STANDARDS. SLOPES SHALL NOT EXCEED 5%
GRADING FOR ALL SIDEWALKS AND ACCESSIBLE ROUTES INCLUDING CROSSING5.
NATURAL AND PAVED AREAS.
CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM BUILDINGS FOR ALL4.
ASSURE A SMOOTH FIT AND CONTINUOUS GRADE.
CONTRACTOR SHALL ADJUST AND/OR CUT EXISTING PAVEMENT AS NECESSARY TO3.
BEEN SHOWN FOR ADDITIONAL CLARITY.
CONTOURS HAVE 2
1WITH THE EXCEPTION OF THE AREA AROUND THE BUILDING WHERE
EXISTING AND PROPOSED GRADE CONTOUR INTERVALS SHOWN AT 1 FOOT INTERVALS.2.
ALL CUT OR FILL SLOPES SHALL BE 3:1 OR FLATTER UNLESS OTHERWISE NOTED.1.
GRADING LEGEND
SW=1278.85'
EXISTING
MATCH
C-104
C-505
FL SW=1272.33 18" RCP
FL S=1272.23 18" RCP
FL E=1271.20 24" RCP
T/R=1275.26
FL=1360.61 18" RCP
T/G=1363.05
FL=1272.59 18" RCP
T/G=1274.92
FL SW=1269.73 24" RCP
FL W=1269.70 24" RCP
FL N=1269.60 24" RCP
T/G=1275.54
FL NE=1271.94 24" RCP
FL S=1271.99 18" RCP
T/G=1274.83
FL W=1275.09 18" RCP
T/G=1270.31
FL S=1269.50 24" RCP
FL E=1269.77 18" RCP
FL N=1269.36 24" RCP
T/R=1275.30
FL E=1264.97 36" RCP
FL N=1267.43 24" RCP
FL W=1267.41 18" CMP
FL S=1267.71 24" RCP
T/G=1274.40
FL W=1264.95 36" RCP
FL E=1264.96 36" RCP
T/G=1274.55
FL W=1264.75 36" RCP
FL E=1264.75 36" RCP
T/G=1274.44
FL S=1270.15 24" RCP
FL W=1270.32 18" RCP
FL N=1270.20 24" RCP
T/R=1276.40
FL S=1270.60 24" RCP
FL N=1270.98 18" RCP
T/G=1275.17
18" RCP
FL S=1359.95
T/G=1363.61
FL S=1275.84 6" PVC
FL E=1274.87 18" RCP
T/G=1277.37
PVT=1276.83
C-503
EL=1276.81
EL=1277.28
FL=1276.50
FL=1276.43
EL =1278.65
C-204
GRADING DETAIL
N.T.S
G=1277.18
TC=1277.68
(MATCH EXIST.)
G=1277.00
TC=1277.50
(MATCH EXIST.)
EL=1276.39
G=1276.48
TC=1276.98
G=1276.96
TC=1277.46
G=1276.77
TC=1277.27
G=1275.99
TC=1276.48
G=1276.19
TC=1276.69
G=1275.82
TC=1276.32
G=1275.78
TC=1276.28
G=1275.70
TC=1276.20
G=1275.66
TC=1276.16
EL=1275.72
EL=1275.66
EL=1276.25
G=1276.18
TC=1276.68
G=1276.16
TC=1276.66
G=1276.21
TC=1276.71
G=1276.33
TC=1276.83
EL =1278.20
EL =1278.02
EL =1277.84
EL =1278.02
DRAIN PIPE (REF. ARCHITECTURAL)
CONST. 6" PERFORATED
TOWARD DRAIN
GRADE AREA
(MATCH EXIST.)
EL = 1276.65
TR=1276.94
MATCH GRADE
MANHOLE TO
ADJUST EXIST.
FL = 1271.15
STUB INTO EX. 24" RCP
BEGIN CONST. 8" PVC PIPE
STA. 10+00.00
PVC PIPE
CONST. 8"
(REF. ARCH.)
OUTLET PIPE
CONST. 6" PVC
BOX TO MATCH GRADE
ADJUST EXIST. VALVE
MATCH GRADE TR=1276.85
LOWER EXIST. PULLBOX TO
TG = 1276.10
FL = 1271.70
GRADE AREA TO DRAIN TO INLET
CONST. INLET BOX STRUCTURE
END CONST. 8" PVC PIPE
STA. 11+04.25
PAD MAX. SLOPE = 0.5%
(FL = 1277.84)
YARD TO DRAIN
SCREEN WALL TO ALLOW
CUT 6" DIA. ORIFICE INTO
TRUNK)
OF 1277.25 AT
(MAINTAIN MIN. ELV
EXISITING TREE
DISTURBANCE AT
MINIMIZE GROUND
(CITY OF OKC STD)
HANDRAIL
CONST 10LF PIPE
(CITY OF OKC STD)
HANDRAIL
CONST 10LF PIPE
(CITY OF OKC STD)
W/ PCES
PVC CULVERT
CONST. 15 L.F. 8"
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -1 jl p .d g n
603030
SHEET SIZE = 22"x 34"
GRAPHIC SCALE
OKC (405) 840-5032
800-522-OKIE (6543)
SYSTEM, INC.
ONE-CALL
OKLAHOMA
TULSA (918) 732-OKIE (6543)
TO ANY EXCAVATION.
CONTACT THESE NUMBERS PRIOR
OF ALL UNDERGROUND UTILITIES.
FOR INFORMATION ON THE LOCATION
THESE NUMBERS ARE TO BE USED
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z R
R
S-1
S-1
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
ZZ
Z
ZZ
Z Z
Z
Z
ZR R
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I I
I
I I
I I
R
R
S-2
RRRR R
RR
R R
R
R
RRRR
RRRR
RRRR
CP
M B
S .W T
H S
T
EDDIE AVE.
FO FO
F O
EDDIE AVE.
B D
G
B D
G
BDG #241
No Parking Sign-
No Parking Sign-
FF=1278.88
RAMP
C-105
R
S-1
P.C. CONCRETE JOINT LEGEND
THICKENED EDGE ABUTTING EXIST A.C. PVMT
EJ
SIDEWALK JOINT LEGEND
Z Z Z
E
CONTRACTION JOINT (DUMMY)
THICKENED EDGE
DUMMY CONTRACTION JOINT
LONGITUDINAL CONSTRUCTION JOINT (TIED)
EXPANSION JOINT
E
LONGITUDINAL CONTRACTION JOINT (DOWELED)
(DO NOT ALLOW BARS TO CROSS JOINTS)
(PANEL SHALL HAVE #4 BARS @ 16" EA. WAY)
REINFORCED PANEL
Z Z Z
MAXIMUM SPACING FOR CONTRACTION JOINTS SHALL BE NO MORE THAN 6.00.'
TRANSVERSE CONSTRUCTION JOINT (TIED)
EXPANSION JOINT (PLAIN)
I I I I I
MAXIMUM SPACING BETWEEN SIDEWALK EXPANSION JOINTS SHALL BE NO MORE THAN 50'.
THICKENED EDGE ABUTTING THICKENED EDGE S-2
EEEXPANSION JOINT (PLAIN)
l l l l
JOINT LAYOUT NOTES:
BDG #15
JOINT LAYOUT SHEET
020 10 20 40
R
R
A MAXIMUM OF 75' SPACING.
EXPANSION JOINTS TO BE CUT INTO SIDEWALKS AT 2.
JOINT SPACING TO MATCH SIDEWALK WIDTH (MAX. 7 FT).1.
3. DOWELS SHALL BE MINIMUM 12" FROM EDGE OF PANEL.
JOINT MATERIAL ALL AROUND PROTRUSION.
AND HAVE 3/4" NON EXTRUDING OR PREFORMED EXPANSION
BOLLARD, FIRE HYDRANT, ETC.) SHALL BE REINFORCED
ANY ITEM PROTRUDING INTO IT (DRAINAGE STRUCTURE,
2. ALL NON -RECTANGULAR SLABS AND ANY SLAB WITH
1. MAXIMUM JOINT PANEL SPACING SHALL BE 15'.
SIDEWALK JOINT LAYOUT NOTES:
P C
S V
A R
IE
S V
A R
IE
S
S
P A
C E
S
.7
.6
10.5' 10.5' 12' 12' 10.5' 10.5'
RR
12 SPCS @ 6'= 72'
4 SPC @ 9.225' = 36.9'
S
P C .5
E
U G
E
UGE
C
SS SS SS SS SS
.O
C.O.
C .O
F H
S S
S D
P L
B
14"
24"
Concrete
E le c ti c O u tl e t
Concrete
C o n c re te
Concrete
A s p h a lt P a v in g
R a m p
R a m p
Concrete
C o n c re te
Concrete
C o n c re te
S p a c e s
S p a c e s
S p a c e s
Grass
G ra s s
Grass
Grass
Grass
Grass
Grass
Grass
Paving Asphalt
FF=1262.72
FF=1278.70
Generator
Drain=1279.27 FL Roof
FF=1278.77
S p a c e s
Gas Connect
FF=1278.70
Bed Rock
Bed Rock
12" PVC
FL Drain=1280.30
FL Drain=1280.24
Water Spigot
S S
S
S S
G G
G
W W
F F
S S
S S
S S
S S
S S
SS
FF=1278.76
FF=1278.78
A s p h a lt
P a v in g
FL S=1272.27 8" Steel FL W=1272.24 12" Steel
FL E=1272.25 18" CMP
FL N=1272.25 12" Steel T/R=1278.28
FF=1278.89
FF=1279.06
FF=1278.89
FF=1278.90
FF=1278.89
FF=1278.85
Roof Drain
FF=1278.84
FF=1278.86
FF=1278.84
Drain=1278.83 FL Roof
2 Spaces Parking Motorcycle
Pipe Size or Type Could not Verify
FL SW=1272.92
FL E=1271.63
FL N=1271.56
T/R=1277.46
W
W18"
U G
E
U G
E U
G E
U G
E
U G
E
UGE
U G
E
SS SS
UGE
UGE
S
S
C.O.
S
S S
FL S=1273.67 12" Steel T/R=1276.00 2 Grates
SS SS
W
W
GATE
RAMP
(#28)
STORAGE
MATERIAL
FL = 1274.84
E =2081158.0555 N = 143938.0556
LINE "B", CONNECT
6" SAN. SEWER SERVICE
STA. 3+00, BEGIN CONST.
EX. FL SW = 1272.92
EX. FL E = 1271.63
FL N = 1272.13
T/R = 1277.46 E =2081157.6900 N = 143842.3932
STUB INTO EXIST. MANHOLE
6" SAN. SEWER SERVICE LINE "B"
STA. 3+95, END CONST.
FL S = 1272.49
EX. FL W = 1271.49
EX. FL E = 1271.46
T/R = 1278.74 E =2081135.3356 N = 144296.1005
SANITARY SEWER MANHOLE
6" SAN. SEWER SERVICE LINE "A", INSTALL
STA. 0+00.00 BEGIN CONST.
FL = 1174.66
E =2081135.4151 N = 144086.3791
STA. 2+09.72
FL = 1274.84
E =2081121.8846 N = 144096.8646
CONNECT TO BDG
6" SAN. SEWER SERVICE LINE "A"
STA. 2+24.64, END CONST.
UNDER EXIST. WALL
BORE SAN SEWER LINE
A
B
C
D
E
F
G
A
B
C
D
E
F
G
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -1 p n p .d g n
OKC (405) 840-5032
800-522-OKIE (6543)
SYSTEM, INC.
ONE-CALL
OKLAHOMA
TULSA (918) 732-OKIE (6543)
TO ANY EXCAVATION.
CONTACT THESE NUMBERS PRIOR
OF ALL UNDERGROUND UTILITIES.
FOR INFORMATION ON THE LOCATION
THESE NUMBERS ARE TO BE USED
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
SHEET SIZE = 22"x 34"
GRAPHIC SCALE
20 401020
December 20, 2019
FINAL TYPE B SUBMITTAL
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
PR
OFE
F L I
N
.0
.6
F L
.8
.8
.2
.5
F L
.2
F L
.5
224.64 L
.F. 6" SAN. SEWER SERVICE LINE @ 1.2
3%
F L
.6
.7
7+00
L
L
BDG #15
BDG #15
4+00 5+00 6+00
BDG #15
12681268 1266
1284 1284 1284
SAN SEWER SERVICE LINE "B"
8+00
(APPROX.)
FF = 1278.78
E =2081103.2590
N = 144044.6695
C-106
F L
.8
A P
P R
O X
T
IE
T
O E
X
IS
T
B D
G
C O
N N
E C
T
IO
N
S
A N S
E W
E R S
E R
V
IC
E L
IN
E
B
S T
A
B E
G
IN
C
O N
S T
F L N
.3
A P
P R
O X
S T
U B I
N T
O E
X
IS
T
M A
N H
O L E
S
A N S
E W
E R S
E R
V
IC
E L
IN
E
B
S T
A E
N D C
O N
S T
BDG #15
F L S
.4
E X F
L W
.4
E X F
L E
.4
T /R
.7
S A
N
IT
A R
Y S
E W
E R M
A N
H O
L E
S
A N S
E W
E R S
E R
V
IC
E L
IN
E
A I
N S
T A
L L
S T
A .0
B E
G
IN
C
O N
S T
F L
.8
C O
N N
E C
T T
O B
D G
S
A N S
E W
E R S
E R
V
IC
E L
IN
E
A
S T
A .6
E
N D C
O N
S T
SAN SEWER SERVICE LINE "A"
C-504 REPAIR
135 S.Y. PVMT.
PLAN & PROFILE
SANITARY SEWER
@ C CONSTRUCTION
EXIST. GRADE
@ C CONSTRUCTION
EXIST. GRADE
95.00 L.F. 6" SAN. SEWER SERVICE LINE "B" @ -1.78%
6"
6"
STORM WATER MANAGEMENT PLAN
EROSION AND SEDIMENT CONTROLSSITE DESCRIPTION
PROJECT LIMITS:
PROJECT DESCRIPTION:
SUGGESTED SEQUENCE OF EROSION CONTROL ACTIVITIES:
SOIL TYPE:
(FOR CONTRACTOR USE)
OFFSITE AREA TO BE DISTURBED:
OF CENTER OF PROJECT:
LATITUDE & LONGITUDE
NAME OF RECEIVING WATERS:
SENSITIVE WATERS OR WATERSHEDS: YES
YES
NO
NO
IN ADDITION:
BE NOTED:
THE FOLLOWING SECTIONS OF THE 2009 ODOT STANDARD SPECIFICATIONS SHOULD
GENERAL NOTES:
HAZARDOUS MATERIALS:
WASTE MATERIALS:
FOLLOWING:
THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THESOIL STABILIZATION PRACTICES:
STRUCTURAL PRACTICES:
MAINTENANCE AND INSPECTION:
OFFSITE VEHICLE TRACKING:
NOTES:
EXCESS DIRT ON ROAD REMOVED DAILY
LOADED HAUL TRUCKS TO BE COVERED WITH TARPAULIN
HAUL ROADS DAMPENED FOR DUST CONTROL
TEMPORARY STREAM CROSSINGS
SANDBAG BERMS
TEMPORARY BRUSH SEDIMENT BARRIERS
INLET SEDIMENT FILTER
RIP RAP
TEMPORARY SEDIMENT REMOVAL
TEMPORARY SEDIMENT FILTERS
TEMPORARY SEDIMENT TRAPS
TEMPORARY SEDIMENT BASINS
TEMPORARY DIVERSION CHANNELS
PAVED DITCH W/ DITCH LINER PROTECTION
TEMPORARY SLOPE DRAIN
ROCK FILTER DAMS
DIVERSION, INTERCEPTOR OR PERIMETER SWALES
DIVERSION, INTERCEPTOR OR PERIMETER DIKES
TEMPORARY FIBER LOG
TEMPORARY SILT DIKES
TEMPORARY SILT FENCE
STABILIZED CONSTRUCTION EXIT
OR AS DIRECTED BY THE ENGINEER.
FOR OVER 14 DAYS. METHODS USED WILL BE AS SHOWN ON PLANS,
ALL DISTURBED AREAS WHERE CONSTRUCTION ACTIVITIES HAVE CEASED
NOTE: TEMPORARY EROSION CONTROL METHODS MUST BE USED ON
PRESERVATION OF EXISTING VEGETATION
SOIL RETENTION BLANKET
VEGETATIVE MULCHING
PERMANENT SODDING, SPRIGGING OR SEEDING
TEMPORARY SEEDING
NOYES
NO
LOCATED IN A TMDL:
LAKE THUNDERBIRD TMDL:
PROJECT WILL DISCHARGE TO:
IF YES, LIST IMPAIRMENT:
YES NOMS4 ENTITY
IF YES, LOCATION:
(d)303 IMPAIRED WATERS:
CONSTRUCTION SITE:
TOTAL AREA OF THE
COEFFICIENT OF THE SITE:
POST-CONSTRUCTION RUNOFF
ESTIMATED AREA TO BE DISTURBED:
PRE-CONSTRUCTION:
TOTAL IMPERVIOUS AREA
POST-CONSTRUCTION:
TOTAL IMPERVIOUS AREA
X
X
X
X
X
X
X
TEMPORARY SEDIMENT CONTROL
STORM WATER POLLUTION PREVENTION AND CONTROL
MANAGEMENT OF EROSION, SEDIMENTATION AND
STORM WATER MANAGEMENT
LAWS, RULES AND REGULATIONS TO BE OBSERVED
STORAGE AND HANDLING OF MATERIAL
ENVIRONMENTAL PROTECTION
CONTRACTOR'S RESPONSIBILITY FOR WORK
FINAL CLEANING UP
BONDING REQUIREMENTS
107.20
107.01
106.08
104.13
104.12
104.10
103.05
X
X
DIVISION, SEPTEMBER 13, 2017.
THE STATE OF OKLAHOMA." ODEQ, WATER QUALITY
DISCHARGES FROM CONSTRUCTION ACTIVITIES WITHIN
"ODEQ GENERAL PERMIT (OKR10) FOR STORM WATER
INSTALLATION OF EROSION CONTROL MEASURES.
A LOG OF THE DATES OF MAJOR SOIL DISTURBANCE ACTIVITIES, AND ALSO THE DATES OF
THEIR EFFECTIVENESS AS APPROVED BY THE ENGINEER. THE CONTRACTOR WILL MAINTAIN
CHOOSE TO MODIFY THE TYPE OR ARRANGEMENT OF SPECIFIED PRACTICES TO IMPROVE
(AT LEAST 70%) HAS BEEN ATTAINED. AS SITE CONDITIONS WARRANT, THE CONTRACTOR MAY
REPLACE SALVAGED TOPSOIL AND DEVICES WHEN AN ACCEPTABLE VEGETATIVE COVER
OPERATIONS AS PRACTICAL. IF DIRECTED BY THE ENGINEER, PLANT TEMPORARY SEEDING.
INSTALL, MAINTAIN AND/OR MOVE TEMPORARY SEDIMENT ITEMS WITH CONSTRUCTION
GRUB ONLY IN NECESSARY AREAS, PRESERVING AS MUCH NATIVE VEGETATION AS POSSIBLE.
SEDIMENT CONTROLS SPECIFIED. STRIP, STOCKPILE AND STABILIZE TOPSOIL. CLEAR AND
SOIL DISTURBING ACTIVITIES, THE CONTRACTOR WILL INSTALL ALL PERIMETER TEMPORARY
PRIOR TO INITIATING
0.50 AC.
X
NEED TO BE INSPECTED.
ENTRANCES AND EXITS ALONG WITH EROSION AND SEDIMENT CONTROL LOCATIONS ARE EXAMPLES OF SITES THAT
POTENTIALLY ERODIBLE AREAS, DRAINAGEWAYS, MATERIAL STORAGE, STRUCTURAL DEVICES, CONSTRUCTION
ANY STORM EVENT GREATER THAN 0.5 INCH AS RECORDED BY A NON-FREEZING RAIN GAUGE TO BE LOCATED ON SITE.
AND ANY NECESSARY REPAIRS SHALL BE PERFORMED ONCE EVERY 7 CALENDAR DAYS AND WITHIN 24 HOURS AFTER
OF CONSTRUCTION UNTIL AN ACCEPTABLE VEGETATIVE COVER IS ESTABLISHED. INSPECTION BY THE CONTRACTOR
ALL EROSION AND SEDIMENT CONTROLS WILL BE MAINTAINED IN GOOD WORKING ORDER FROM THE BEGINNING
COMPOUNDS AND CONTAMINATED SOILS.
BUT ARE NOT LIMITED TO: PAINTS, ACIDS, CLEANING SOLVENTS, CHEMICAL ADDITIVES, CONCRETE CURING
ENSURE CORRECT HANDLING, DISPOSAL, SPILL PREVENTION AND CLEANUP MEASURES. EXAMPLES INCLUDE
RESPONSIBLE FOR FOLLOWING MANUFACTURER'S RECOMMENDATIONS, STATE AND FEDERAL REGULATIONS TO
PROPER MANAGEMENT AND DISPOSAL OF HAZARDOUS WASTE MATERIALS IS REQUIRED. THE CONTRACTOR IS
PRACTICES FOR CONTROLLING STORM WATER POLLUTION.
INTERCEPTION OF THESE POLLUTANTS BEFORE LEAVING THE CONSTRUCTION SITE ARE THE BEST
PROCESS. THE PREVENTION OF SOIL EROSION, CONTAINMENT OF HAZARDOUS MATERIALS AND/OR THE
POLLUTION DUE TO EXPOSED SOILS AND THE PRESENCE OF HAZARDOUS MATERIALS USED IN THE CONSTRUCTION
POLLUTANTS IN STORM WATER DISCHARGES. RUNOFF FROM CONSTRUCTION SITES HAS A POTENTIAL FOR
PLANTS, ETC. THE BASIC GOAL OF STORM WATER MANAGEMENT IS TO IMPROVE WATER QUALITY BY REDUCING
MUST BE DOCUMENTED IN THE SWPPP, I.E., BORROW PITS, WORK ROADS, DISPOSAL SITES, ASPHALT/CONCRETE
THE PROGRESSION OF THE PROJECT. ALL CONTRACTOR OFF-SITE OPERATIONS ASSOCIATED WITH THE PROJECT
ENVIRONMENTAL QUALITY (ODEQ). THE PLAN MUST BE KEPT CURRENT WITH UP-TO-DATE AMENDMENTS DURING
INTENT (NOI) FORM AND PERMIT CERTIFICATE THAT HAVE BEEN FILED WITH THE OKLAHOMA DEPARTMENT OF
CONFIRMED IN THE PRE-WORK MEETINGS AND AVAILABLE ON THE JOB SITE ALONG WITH COPIES OF THE NOTICE OF
DISCHARGE ELIMINATION SYSTEM (OPDES) REGULATIONS. THIS PLAN IS INITIATED DURING THE DESIGN PHASE, A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IS REQUIRED TO COMPLY WITH THE OKLAHOMA POLLUTION
COW CREEK
X
X
X
0.86
ENTEROCOCCUS AND ESCHERICHIA COLI
TURBIDITY, DISSOLVED OXYGEN, pH, SELENIUM, OKLAHOMA CITY MANAGEMENT PLAN
STORM WATER
SITE IMPROVEMENTS TO INCLUDE: PAVEMENT, SIDEWALK, UTILITY CONNECTIONS AND GRADING.
RENOVATION OF EXISTING BASE MAINTENANCE BUILDING #15.
OF S. EDDIE AVE. AND S.W. 68th ST. INTERSECTION.
FAA BDG MAINTENANCE #15, FAA MMAC, OKLAHOMA CITY. NORTHEAST
CONTROLS AND PRACTICES SHALL MEET THE REQUIREMENTS OF ALL FEDERAL, STATE AND LOCAL AGENCIES.
PROCESS. PRACTICES INCLUDE DISPOSAL, PROPER MATERIALS HANDLING, SPILL PREVENTION AND CLEANUP MEASURES.
MATERIALS INCLUDE STOCKPILES, SURPLUS, DEBRIS AND ALL OTHER BY-PRODUCTS FROM THE CONSTRUCTION
PROPER MANAGEMENT AND DISPOSAL OF CONSTRUCTION WASTE MATERIAL IS REQUIRED BY THE CONTRACTOR.
LAT: N 35 23' 38" LONG: W 97 37' 18"
SILTY CLAY LOAM
2. 57 A.C.
1.61 A.C.
1.36 A.C.
2.1 A.C.
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -1 s m p .d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
PR
C-107
E U
G E
U G
E
U G
E U
G E
UGE
UGE UGE
U G
E U
G E
UGE
C C
C C C C C C CC C
C
C
C
UGE UGE UGE
UGE
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -1 e ro .d g n
603001530
SHEET SIZE = 22"x 34"
GRAPHIC SCALE
OKC (405) 840-5032
800-522-OKIE (6543)
SYSTEM, INC.
ONE-CALL
OKLAHOMA
TULSA (918) 732-OKIE (6543)
TO ANY EXCAVATION.
CONTACT THESE NUMBERS PRIOR
OF ALL UNDERGROUND UTILITIES.
FOR INFORMATION ON THE LOCATION
THESE NUMBERS ARE TO BE USED
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
SS
S
SS
S S
SS SS SS
S S
C .O
C.O.
C .O
CP
CP
CP
F H
G V
GV
IC
V
ICV
IC
V
IC
V
IC
V
M B
S S
S S
S D
S D
S D
S D
P L
B
W V
W V
W V
W V
W V
S D
S S
G
DENNING AVE.
S .W T
H S
T
24"
14"
24"
36"
6"
6" 6" 6"
Concrete
Gas Manhole
E le c ti c O u tl e t
Concrete
A s p h a lt P a v in g
Concrete
C o n c re te
C o n c re te
Concrete
C o n c re te
Concrete
C o n c re te
C o n c re te
Concrete
A s p h a lt P a v in g
A s p h a lt P a v in g A s p h a lt P a v in g
A s p h a lt P a v in g
Asphalt Paving
A s p h a lt P a v in g
A s p h a lt P a v in g
C o n c re te
C o n c re te
R a m p
R a m p
R a m p
R a m p
ConcreteC o n c re te
A s p h a lt P a v in g
Concrete
C o n c re te
C o n c re te
C o n c re te
Concrete
Concrete
Asphalt Paving
Concrete
Concrete Concrete 28 Spaces
C o n c re te
S p a c e s
S p a c e s
S p a c e s
S p a c e s
S p a c e s
S p a c e s
S p a c e s
S p a c e s
Concrete
R a m p
Concrete
C o n c re te
R o c k B e d
Grass
Grass
G ra s s
Grass
Grass
Grass
Grass Grass
Grass
Grass Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Grass
Paving Asphalt
C o n c
C o n c
C o n c
FF=1278.78
No Parking Sign-
Fire Connect
FF=1278.80
Transformer
1 Garage Door Man Door and Concrete Pit W/1
FF=1278.79
Bollard
EDDIE AVE.
Stairs
Drain Roof
FF=1262.72
FF=1278.70
Bollards
Generator
Drain=1279.27 FL Roof
Comm Box
FF=1278.77
GV's
No Parking Sign-
No Parking Sign-
VAULT
W
FH
S .W T
H S
T
FL SW=1272.33 18" RCP
FL S=1272.23 18" RCP
FL E=1271.20 24" RCP
T/R=1275.26
FL=1272.59 18" RCP
T/G=1274.92
Ramp Concrete
S p a c e s
Sign- SW 68th St.
Gas Connect
FF=1278.70
Bed Rock
Bed Rock
12" PVC
FL Drain=1280.30
FL Drain=1280.24
Water Spigot
FL W=1275.09 18" RCP
T/G=1270.31
FL S=1269.50 24" RCP
FL E=1269.77 18" RCP
FL N=1269.36 24" RCP
T/R=1275.30
Bed Rock
Sign-SW 68th Street
FL SW=1269.73 24" RCP
FL W=1269.70 24" RCP
FL N=1269.60 24" RCP
T/G=1275.54
FL N=1272.19 18" RCP
T/G=1274.63
FL NE=1271.94 24" RCP
FL S=1271.99 18" RCP
T/G=1274.83
VAULT
W
FL W=1264.75 36" RCP
FL E=1264.75 36" RCP
T/G=1274.44
FL W=1264.95 36" RCP
FL E=1264.96 36" RCP
T/G=1274.55
FL E=1264.97 36" RCP
FL N=1267.43 24" RCP
FL W=1267.41 18" CMP
FL S=1267.71 24" RCP
T/G=1274.40
Sign-Janitorial Service
Sign-Base MaintenanceFL S=1270.15 24" RCP
FL W=1270.32 18" RCP
FL N=1270.20 24" RCP
T/R=1276.40
FL S=1270.60 24" RCP
FL N=1270.98 18" RCP
T/G=1275.17
18" RCP
FL S=1359.95
T/G=1363.61
FL S=1275.84 6" PVC
FL E=1274.87 18" RCP
T/G=1277.37
S S S SS S S S
S S
S S
S
S S
S S
S S
S
G GG
G
G G
G G
G
G
G G
W W
W W
W W
W
F F
FO FO
F O
S S
S S
S S
S S
S S
S S
S S
SSSS
S S
S S
S S
S S
SS
EDDIE AVE.
FF=1278.76
FF=1278.78
A s p h a lt
P a v in g
FL S=1272.27 8" Steel FL W=1272.24 12" Steel
FL E=1272.25 18" CMP
FL N=1272.25 12" Steel T/R=1278.28
FF=1278.89
FF=1279.06
FF=1278.89
FF=1278.90
FF=1278.89
FF=1278.85
Roof Drain
FF=1278.84
FF=1278.86
FF=1278.84
Drain=1278.83 FL Roof
2 Spaces Parking Motorcycle
3 Spaces 10 Spaces
No Parking Sign-
Pipe Size or Type Could not Verify
FL W=1272.02
FL W=1273.68
FL E=1272.00
T/R=1278.52
Pipe Size or Type Could not Verify
FL W=1270.19
FL N=1270.14
T/R=1277.46
FL=1360.61 18" RCP
T/G=1363.05
Pipe Size or Type Could not Verify
FL SW=1272.92
FL E=1271.63
FL N=1271.56
T/R=1277.46
F H
F
F
W
W
W
W
W
S S S
S
SS SS SS SS SS SS SS SS
MHMH
G
G G G G
W
GV
W M
W
18"
E
E
MH MH
UGE
UGE UGE UGE UGE UGE UGE UGE UGE
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E
UGE
UGE
UGE
UGE
UGE
UGE
U G
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
UGE
U G
E U
G E
U G
E
SS SS
C C
C
U G
E U
G E
U G
E U
G E
G
SS
UGE
UGE
G
G G
S S
SS
S S S S S
UGE UGE UGEUGE UGE UGE UGE UGE
U G
E
C
SS
B D
G
BDG #267
B
D G
B D
G
BDG #241
S
S
C.O.
S
S S
FL S=1273.67 12" Steel T/R=1276.00 2 Grates
SS
W
W
Bollard
No Parking Sign-
No Parking Sign-
& S.W. 67th Sign- Eddie
FF=1278.88
Do Not Enter Sign-
Sign- One Way
Sign- Yield
GATE
RAMP
EROSION CONTROL LEGEND
Z
C-108
EROSION CONTROL PLAN
BDG #28
BDG #15
Z
Z
Z
Z
Z
Z Z
Z Z
Z Z
Z Z
Z Z
Z
Z
Z Z Z Z
Z
Z Z
Z
Z Z
ZZ
Z Z Z Z
CONC. WASHOUT
INLET BARRIER
TEMP. ROCK BAG
TEMP. SILT FENCE
INLET BARRIER
ROCK BAG
INSTALL TEMP.
BAG INLET BARRIER
INSTALL TEMP. ROCK
SILT FENCE
INSTALL TEMP.
(TYP.)
SILT FENCE
INSTALL TEMP.
(CONFIRM LOCATION WITH FAA).
ASSUMED CONCRETE WASHOUT LOCATION
C-507
C-507
C-507
C-507
C-508
N.T.S.
N.T.S. N.T.S.
DOWEL BASKET DETAILS 2
JOINT SEALANT DETAILS
PAVING JOINT DETAILS 1
EXIST
UNDERLYING MATERIAL
(ABUTTING EXISTING A.C. PAVEMENT)
Tx1.25
T /2 -1 /2
REINFORCED PANEL
TYPE (S-1) THICKENED EDGE
TO A NEAT LINE
SAW CUT EXISTING MATERIALS
IN.
THICKNESS
PAVEMENT
DOWEL DIAMETER
AND TYPEIN.
SPACING
DOWEL
MAXIMUM
IN.
LENGTH
DOWEL
MINIMUM
DOWEL DATA CHART
1 - IN. DOWEL
12"
12"16"8" TO 11.5"
8" 16"
GENERAL NOTES
1. WHEN DOWELING INTO EXISTING PAVEMENT, DOWEL SHALL BE AT
2. ALL JOINT SEALING MATERIALS AND METHODS SHALL BE APPROVED
CENTER OF THINNEST CONCRETE SECTION.
PRIOR TO USAGE.
- IN. DOWEL4
BE USED.
MANUFACTURE RECOMMENDED RESERVOIR DIMENSIONS SHALL
ABOVE SEALANT RESERVOIR DIMENSIONS ARE APPROXIMATE.
NOTE:
STAKE
# 4 GA. WIRE
#3/0 GA. WIRE
DOWEL BASKET FOR EXPANSION JOINT
STAKE
DOWEL
#3/0 GA. WIRE
4 #7 GA. WIRE
DOWEL BASKET FOR CONTRACTION JOINT
TYPE (E) EXPANSION JOINT - PLAIN
MATERIAL (ASTM 1751)
EXPANSION JOINT
SEE CHART THIS SHEET
FOR DOWEL BAR SIZE
5'-0" MIN. 5'-0" MIN.
THICKENED EDGE THICKENED EDGE
TYPE (S-2) THICKENED EDGE
(THICKENED EDGE ABUTTING THICKENED EDGE)
FOR CORRECT SIZE
SEE DOWEL CHART
NON-EXTRUDING
1"
T /2
T
T
(TRANSVERSE OR LONGITUDINAL)
DUMMY CONTRACTION JOINT
3"
3/4"
T
T
NEW CONCRETE PAVEMENT
BITUMINOUS
EXISTING
T x .2
5 T
3/4"
#4 @ 16" E.W.
SEE CHART THIS SHEET
FOR DOWEL BAR SIZE
FILLER
BOND
BREAKER
3/4"
/4
/4
(EXPANSION JOINT)
JOINT SEALANT DETAIL No 3
OR COMAPTIBLE
(ASTM 5893)
JOINT SEALANT
SILICONE
PAVEMENT
NEW RIGID
BIT. PAVEMENT
EXISTING
3/8"
/8
(CONSTRUCTION JOINT)
JOINT SEALANT DETAIL No 4
OR COMAPTIBLE
(ASTM 5893)
JOINT SEALANT
SILICONE
T /3
M
IN
/8
/2
3/8"
1/8" NOM.
ROD
1/2" BACKER
/4
(CONTRACTION JOINT)
JOINT SEALANT DETAIL No 1
OR COMAPTIBLE
(ASTM 5893)
JOINT SEALANT
SILICONE
ROD
1/2 " BACKER
3/8"
/8
/2
M
IN
/4
(CONSTRUCTION JOINT)
JOINT SEALANT DETAIL No 2
OR COMAPTIBLE
(ASTM 5893)
JOINT SEALANT
SILICONE
BUTT JOINT
3/4" +/- 1/8" SEE CHART FOR SIZE.
ONE END OILED.
EPOXY COATED W/
TRANSVERSE DOWEL,
(CONSTRUCTION JOINT)
LONGITUDINAL-DOWELED
T
BUTT JOINT
#5 DEFORMED BARS 30" LONG @ 18"C/C
3/4" +/- 1/8"
T
SEE CHART THIS SHEET
FOR DOWEL BAR SIZE
SEE CHART FOR SIZE
ONE END OILED.
EPOXY COATED W/
TRANSVERSE DOWEL,
T
TYPE (E) EXPANSION JOINT - DOWELED
DETAIL 4
SEE JOINT SEALANT
FOR THICKNESS
SEE TYPICAL SECTION
EDGE
THICKENED
5'-0"
DETAIL 1
SEE JOINT SEALANT
T/2
(CONTRACTION JOINT)
LONGITUDINAL - DOWELED
DETAIL 2
SEE JOINT SEALANT 1/2" +/- 1/8"
T/2
/8
(CONSTRUCTION JOINT)
LONGITUDINAL-TIED
1/2" +/- 1/8"
DETAIL 2
SEE JOINT SEALANT
/8
" DETAIL 1
SEE JOINT SEALANT
DETAIL 3
SEE JOINT SEALANT
DETAIL 3
SEE JOINT SEALANT
THRU PAVEMENT
OTHER STRUCTURE PROJECTING
BUILDING,MANHOLE OR
PAVEMENT OR
SLIP FIT
EXPANSION CAP,
THIS END OILED
EPOXY COATED W/DETAIL 3
SEE JOINT SEALANT
T/2
PAVING JOINT DETAILS
C-501
C-501 C-501
C-501
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 p jd .d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
1/8" R
3STD. BARRIER CURB & GUTTER
N.T.S.
CURB TERMINAL DETAIL 4
N.T.S.
SIDEWALK DETAILS 1
WIRE MESH REINFORCING
6" X 6" - W 2.9 X W 2.9 WELDED
COMPACT 95% STD. PROCTOR DENSITY
1/8"
CONTRACTION JOINT
EXPANSION JOINT (EJ)
OTHER STRUCTURES AND AT 50' MAX.
WHERE ABUTTING BUILDING OR
CLEAR
3"
1/2"R
"R21
"R21
SECTION
AND JOINT SPACING 7'-0" (7'-8' WIDE)
MAXIMUM CONTRACTION JOINT SPACING 6'-0" (6' WIDE OR LESS)
(IF REINFORCING REQ'D)
LINE
GUTTER
VARIES - 3' OR 6'
CONTRACTION JOINT
TOP OF CURB
FACE OF CURB
#3 BARS #3 BARS
1'-4"
/2 M
IN
#3 BARS
/2
6 1/2" SLOPE IS TOWARD CURB
FOR USE WHEN PAVEMENT
IS AWAY FROM CURB
FOR USE WHEN PAVEMENT SLOPE
GUTTER
TOE OFLEVEL
" BATTER2
No. 4 BARS.
DELETED. REMAINING No. 3 BARS ARE TO BE INCREASED TO
3. WHEN SLIP FORM IS USED, REBAR IN CURB SECTION MAY BE
EXPANSION JOINT.
CONTRACTION JOINTS BUTT END 3" EITHER SIDE OF
2. REINFORCING BARS ARE CONTINUOUS ACROSS
TEMPLATE, AS APPROVED BY ENGINEER.
AND RADII MAY BE MODIFIED TO FIT CONTRACTOR'S
1. IF CURB CONSTRUCTED BY CURB MACHINE, CURB BATTER
NOTE:
/4
4" 8"
2 1/2"
LINE
GUTTER 3
/4
/4
1/2"
OR COMAPTIBLE
(ASTM 5893)
JOINT SEALANT
SILICONE
JOINT FILLER
PREMOLDED EXPANSION
BREAKER
BOND
/4
C-502
C-502
C-502
C-502
N.T.S.
ALL DIMENSIONS TO THIS POINT
EXCEPT SIDEWALKS
TO THIS POINT
DIMENSIONED
SIDEWALKS
BACKFILL
COMPACTED
TYP. 6" P.C. CONCRETE PAVING SECTION
AND DIMENSIONS.
BARRIER CURB & GUTTER DETAILS
SEE DETAIL 5 C-502 FOR STD.
C-502
TYPICAL PAVEMENT SECTIONS
N.T.S.
ALL DIMENSIONS TO THIS POINT
EXCEPT SIDEWALKS
TO THIS POINT
DIMENSIONED
SIDEWALKS
BACKFILL
COMPACTED
12"
C-502
BARRIER CURB & GUTTER
EXIST. ASPHALT PVT.
EXIST. PAVEMENT SECTION WITH NEW BARRIER CURB & GUTTER
C-505
NOTE:
2.
1.
PAVEMENT
N.T.S.
NON-REMOVABLE BOLLARD DETAIL 6
C-502
BACKFILL
COMPACTED
#4 BARS
N.T.S.
C-502
P.C. CONCRETE PAVING SECTION FOR CHILLER PAD
EQUAL ELEVATION.
BOLLARD TOPS ARE TO BE OF
APPROVED YELLOW.
ABOVE GRADE 2 COATS OF
ZINC CHROMATE ALL OVER.
PRIME POSTS WITH 2 COATS
PAVEMENT NOTES:
FROM TOP).
3" WIDE (3" AND 9"
3M REFLECTIVE TAPE,
SCHEDULE 40
6" BLACK IRON PIPE,
FILL WITH CONCRETE
MATERIAL
PREMOLDED COMPRESSIBLE
3#4" NON EXTRUDING OR
2000 PSI CONC. (MIN.)
M
IN
VARIES - SEE PLAN
1'-6"
OPTIMUM MOISTURE CONTENT.
COMPACTION, THE SOIL SHOULD BE ADJUSTED TO WITHIN 2 PERCENT OF ITS
COMPACTED TO A 95% STD. PROCTOR DENSITY AS PER SPECIFICATIONS. PRIOR TO
(RATE TO BE DETERMINED BY GEOTECHINCAL ENGINEER). SUBGRADE TO BE
IF MODIFED SUBGRADE IS USED, TOP 8”SHALL BE STABILIZED WITH HYDRATED LIME(4)
DENSITY.
AGGREGATE BASE COURSE SHALL BE COMPACTED TO 98% ASTM D 698 LABORATORY(3)
REINFORCEMENT JOINTS.
REFER TO JOINT LAYOUT PLAN, C212, FOR DETAILS OF ALL CONCRETE(2)
OTHER PRIORITY AREAS LOCATED BY THE ENGINEER.
SLOPES OF THE CUT SECTIONS AND THE REMAINDER ON COMPLETED FILL SLOPES OR
RESERVED TOPSOIL SHALL BE SPREAD APPROX. 5" THICK FIRST ON THE COMPLETED
AND PLACE IT BACK ON THE SECTION IN ACCORDANCE WITH THE SPECIFICATIONS.
THE CONTRACTOR SHALL STRIP ALL OF THE AVAILABLE TOPSOIL, STOCKPILE IT,
TOPSOIL NOTE:(1)
(REF. CITY OF OKC STANDARDS) (2)
6" P.C. CONC. PAVEMENT
(REF. CITY OF OKC STANDARDS) (3)
6" COMPACTED AGGREGATE BASE
COMPACTED TO 95% OF S.P.D.(4)
8" FLY ASH OR CKD MODIFIED SUBGRADE
10" P.C. CONC. PAVEMENT (2)
6" COMPACTED AGGREGATE BASE (3)
COMPACTED TO 95% OF S.P.D. (4)
8" FLY ASH OR CKD MODIFIED SUBGRADE
SLOPE VARIES
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 ty p .d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
SIGN MOUNTING DETAIL
2 3/8" O.D.
GALVANIZED POST
N.T.S.
RESERVED
PARKING
N.T.S.
STRIPING NOTES
5'-6"
F A
C E O
F C
U R
B
T O
2'-0"
PAINT WHITE
TRAFFIC PAINT ROYAL BLUE
OF PARKING SPACE (CENTERLINE)
CENTER PAINTED SYMBOL IN MIDDLE
TRAFFIC PAINT WHITE
2'-4"
4"
1' -9 "R
6"R.
45°
4"
"T
Y P
94°
114°
2'-2"
10"
2"
104°
4"
N.T.S.
DISABLED ACCESS SYMBOL PAINT DETAIL
NOTE:
4. STRIPING COLOR TO BE YELLOW (PER USER).
3. STRIPING SHALL BE AS SPECIFIED.
2. DIAGONAL STRIPING SHALL HAVE A 12" SPACE BETWEEN STRIPES.
1. ALL STRIPING SHALL BE 4" WIDE, UNLESS OTHERWISE NOTED.
5. CONCRETE SHALL BE 3,000 P.S.I.
AND HIGHWAYS. AND SHALL BE SIMILAR TO SIGN NO. R1-1, R5-1A, & R6-1(L&R) IN ANSI D6.1., (2009 - Rev.2, May 2012) MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS
CLAMPS SHALL BE TWO-PIECE ASSEMBLIES OF AT LEAST 14 GAGE STEEL, OR
SHALL BE AN ADJUSTABLE STEEL-STRAP BRACKET AS APPROVED.
GALVANIZED STEEL. BOLTS SHALL BE A MINIMUM OF 5/16-INCH IN DIAMETER.
4. BOLTS, NUTS, WASHERS, AND CLAMPS SHALL BE EITHER CADMIUM PLATED OR
AND SHALL CONFORM TO THE INDICATED DETAILS.
3. POSTS AND SLEEVES SHALL BE STANDARD SCHEDULE 40 GALVANIZED STEEL PIPE
CONFORM TO ANSI D6.1.
2. EXCEPT WHERE OTHERWISE INDICATED OR SPECIFIED, ALL MATERIALS SHALL
2009.
OF TRANSPORTATION STANDARD SPECIFICATION FOR HIGHWAY CONSTRUCTION, EDITION
1. SIGNS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE OKLAHOMA DEPARTMENT
NOTES:
6"
1/4" 4 3/4"
P.C. CONCRETE
1" STEEL DOWEL-18"
2"
9 1/2"
2"
/2
REINFORCED RODS
2 NO. 4
1" PIPE SLEEVE
SECTION A-A
TOP VIEWB-B
B-B A A
SECTION B-B
END VIEW
7'-0"
1'-1"
6" 6'-0"
CHAMFER P.C. CONCRETE
1'-1"
6"
CHAMFER#4 REINFORCED RODS
1REMOVABLE CURB DETAIL
N.T.S.
GENERAL NOTES
ADA RAMP, STRIPING AND REMOVABLE CURB PLACEMENT DETAIL
3. HC PARKING AREAS SHALL HAVE 2% SLOPE MAX.
2. ALL RAMPS SHALL CONFORM TO A 1:12 SLOPE MAXIMUM.
OBTAINED BY HEAVY BROOMING, TRANSVERSE TO SLOPE.
1. SURFACE TEXTURE OF RAMP & SIDE FLARE SHALL BE
GENERAL ACCESSIBILITY NOTES:
* CROSS SLOPE CAN NOT EXCEED 2%
* SURFACE TEXTURES TO BE:
DIFFERENCE OF 70% FROM SURROUNDING SURFACES
* SURFACE TO HAVE REFLECTIVE LIGHT VALUE
FOR SLOPE AND SURFACE FINISH
* ALL HANDICAP RAMPS TO MEET A.D.A. REQUIREMENTS
NOMINAL 2.35 INCHES.
CENTER TO CENTER SPACING OF
A HEIGHT OF NOMINAL 0.2 INCHES, AND A
WITH A DIAMETER OF NOMINAL 0.9 INCHES,
TRUNCATED DOMES:
INDICATED
WALL MOUNTING AS
SIGN TO BE USED FOR
C-503
8'
MAX.
1:12
8'
MAX.
1:12
MAX.
2%
MAX.
2%
M A
X
M A
X
C-503
C-503
C-503
C-503
1'-0"
1'-6"
9'11'5'11'5'11'5'11'9'
(P
O S
T O
R W
A L L M
O U
N T
E D
C-503
C-503
TYP.
CURB (TYP.)
REMOVABLE
C-503(TYP.)
SYMBOL
SEE NOTE THIS SHEET
TRUNCATED DOMES
R1-2
MISCELLANEOUS DETAILS II
M A
X
M A
X
:1
G=1276.65
TC=1277.15
G=1276.68
TC=1277.18
G=1277.01
TC=1277.51
G=1277.07
TC=1277.57
G=1277.37
TC=1278.40
MAX.
2%
ENSURE COMPLIANCE WITH ADA STANDARDS SEC 703.7.2.12.
PAINT IN ACCORDANCE WITH ODOT STANDARDS AND SPECIFICATIONS.1.
G=1276.93
TC=1277.43
G=1277.39
TC=1277.89
EL=1278.58EL=1278.64
G=1277.13
TC=1277.63
G=1276.74
TC=1277.24
G=1276.71
TC=1277.21
G=1276.88
TC=1277.38
G=1277.07
TC=1277.57
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 m d t.
d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
CLEANOUT DETAIL
FINISHED GRADE
AND COVER TO BE FLUSH WITH
TO NEENAH R-1976. TOP OF FRAME
CAST IRON FRAME AND COVER SIMILAR
DIRECTLY OVER SEWER
BEND WHEN CLEANOUT IS
USE "Y" BRANCH AND 45°
(SEE NOTE 1)
TRACE WIRE2 CU. FT. CONCRETE
SEWER BRANCHES OFF.
OR TWO 45° BENDS WHEN
USE 90° LONG RADIUS BEND
WITH SILICONE.
ENTER. SEAL HOLE WATERTIGHT
6" LOOP OF TRACE WIRE TO
HOLE IN PIPE BELOW CAP FOR
VERTICAL FOOT. DRILL SMALL
AROUND PIPE AT 3 WRAPS PER
WRAP DOUBLED TRACE WIRE
FINISHED GRADE
STEEL TO BE CUT ON JOB SITE.
TO DIMENSIONS SHOWN. REINFORCING
SHOP SHALL SCORE CONCRETE WALLS
NOTE:
A GASKETED, FLEXIBLE, WATERTIGHT CONNECTION.
2. CONNECT INLET & OUTLET PIPES TO MANHOLE WITH
(C-478 LATEST EDITION).
WITH THE RESPECTIVE A.S.T.M. SPECIFICATIONS
1. ALL PRECAST COMPONENTS SHALL BE REINFORCED
NOTES:
PIPE CONNECTION DETAIL
D
RCP ASTM C-478
4'-0" OR 5'0" I.D.
RISER SECTION TO BE
OR CONCENTRIC
EITHER ECCENTRIC
MANHOLE REDUCER
4'-0" OR 5'-0"R.C.P.
LETTERING "STORM SEWER"
TRACTOR. (ADJUST TO GRADE).
AND INSTALLED BY THE CON-
AND FRAME TO BE FURNISHED
MANHOLE, CAST IRON COVER
NEENAH R-1682 HEAVY DUTY
FINISH GRADE
PAVEMENT OR
(2000 PSI CONCRETE)
TO FLOW LINE OF PIPE
POUR MANHOLE INVERT
CONCRETE
3,000 PSI
CRUSHED ROCK (4" MIN.)
#4 @ 12" C/C EA. WAY
PIPE
6'-0" DIA.
5'-0" OR
4'-0"
JUNCTION BOX
TYPICAL MANHOLE
(NOT STORM SEWER)
PLASTIC/NON-PLASTIC PIPE
TRENCH CROSS SECTION DETAIL
N.T.S.
MATERIAL
COMPACTED BEDDING
BACKFILL
INITIAL
BACKFILL
FINAL
COMMON FILLFINISH GRADE
NOTE 1)
(SEE TRACER WIRE
TRACER WIRE
MAX OD
12"
MAX
12"
NON-TRAFFIC AREAS
N.T.S.
1STD. PRECAST MANHOLE DETAIL
D
NOTES:
ONE EACH SIDE
4 - #4 BARS
PIPE
CONCRETE
24" x 24" x 10"
D+8"
30"
8" 8"
MORTAR
TAPE
IDENTIFICATION
8"
5"
BOOT SHALL MEET ASTM C-923.
2. NEOPRENE-EPDM BLENDED COMPOUND
1. PIPE CLAMP SHALL BE STAINLESS STEEL.
NOTE:
PIPE O.D.
SUGGESTED
RANGE (IN.)
3 1/2" - 4 1/2"
5 3/8" - 7"
7" - 8 1/2"
8 3/16" - 9 3/4"
9 1/4" - 11"
10 3/4" - 12 1/2"
12" - 13 3/4"
14 1/2" - 16 1/4"
15 3/4" - 17 1/2"
19 1/2" - 21 1/4"
7"
12"
12"
12"
16"
16"
16"
20"
20"
24" 22 7/8"
18 7/8"
18 7/8"
14 7/8"
14 7/8"
14 7/8"
10 7/8"
10 7/8"
10 7/8"
6 1/8"
A B
4 1/4"
6 1/2"
8"
9 1/4"
10 1/2"
12"
13 1/4"
15 3/4"
17"
20 3/4"
6"
8"
8"
8"
8"
8"
8"
8"
8"
8'
C D
HOLE & BOOT DIAMETER DIMENSIONS
5MANHOLE PIPE CONNECTION DETAIL
N.T.S.
(TORQUE TO 60 IN. LBS.)
PIPE CLAMP
STAINLESS STEEL
C
D
B A
STRUCTURE
MANHOLE BASE
CLAMP
INTERNAL EXPANDING
INTERCEPTOR LINE
CONNECTION
MANHOLE
CORE-DRILLED HOLE
FLOW LINE
NEOPRENE-EPDM
FOUNDATION
CRUSHED ROCK
3/8"
PIPE DIAM. MIN. TRENCH WIDTH
RECOMMENDED MINIMUM TRENCH WIDTHS
(75T AXLE LOAD) *
HEAVY CONSTRUCTION
PIPE DIAM.
SURFACE LIVE LOADING CONDITION
VECHICLE LOADING CONDITIONS
MINIMUM RECOMMENDED COVER BASED ON
H-25
* VEHICLES IN EXCESS OF 75T MAY REQUIRE ADDITIONAL COVER
60"
48"
24"
12"
54" - 60"
12" - 48"
60"
54"
48"
42"
36"
30"
24"
18"
15"
12"
10"
8"
6"
4"
96"
88"
80"
72"
64"
56"
48"
39"
34"
30"
28"
26"
23"
21"
IDENTIFICATION TAPE
(SEE TABLE)
MIN. TRENCH WIDTH
TRENCH WIDTH
6" FOR 30"-60" PIPE
4" FOR 4"-24" PIPE
N.T.S.
4PLASTIC PIPE
STORM SEWER INSTALATION DETAIL
FILTER FABRIC
BACKFILL
FINAL
BACKFILL
INITIAL
HAUNCH
BEDDING
FOUNDATION
SUITABLE
SPRINGLINE
(I F A
P P
L
IC
A B
L E
F L E
X
IB
L E P
A V
E M
E N
T
H
M
IN
C O
V E
R
O
(I
A
P P
L
IC
A B
L E
R
IG
ID
P
A V
E M
E N
T
H
M
IN
C O
V E
R T
O
TAPE
IDENTIFICATION
STANDARD PROCTOR DENSITY ASTM D 698.
3. UNDER PAVEMENT FINAL AND INITIAL BACKFILL TO 95%
PROCTOR DENSITY.
2. NONTRAFFIC FINAL & INITIAL BACKFILL TO 90% STANDARD
1. PROVIDE BEDDING IN ACCORDANCE WITH THE SPECIFICATIONS.
NOTES:
STANDARD PROCTOR DENSITY ASTM D 698.
3. UNDER PAVEMENT FINAL AND INITIAL BACKFILL TO 95%
PROCTOR DENSITY.
2. NONTRAFFIC FINAL & INITIAL BACKFILL TO 90% STANDARD
1. PROVIDE BEDDING IN ACCORDANCE WITH THE SPECIFICATIONS.
STRUCTURE
INVERT
BASE
MANHOLE
C-504
C-504
C-504
C-504
C-504
C-504
MISCELLANEOUS DETAILS III
24"
36"
12" OR LESS
(W/ SHORING)
TRENCH WIDTH
PIPE SIZE I.D.
(W/O SHORING)
TRENCH WIDTH
TRENCH WIDTH SCHEDULE
N.T.S.
EXISTING PAVING
BASE MATERIAL
EXISTING UNDISTURBED
#4 BARS @ 18" C/C
#6 BARS @ 6" C/C
PLASTIC PIPE
TRACER WIRE FOR
P.C. CONCRETE
3500 P.S.I.
TACK COAT
SEE SCHEDULE
TRENCH WIDTH VARIES
"2
12" 12"
TYPICAL PERMANENT REPAIR FOR PAVING
6" HDPE GAS LINE
ASPHALT
TYPE "B"
PROJECT SPECIFICATIONS.
SHALL BE IN ACCORDANCE WITH
ALL CONSTRUCTION & MATERIALS
REPAIR NOTE:
" MAX.2
CRUSHER RUN
ABOVE SEWER LINE 12" BELOW FINISHED GRADE.
LABELED "CAUTION SEWER LINE BURIED BELOW," OR SIMILAR WORDING, DIRECTLY
CONNECT TO EXISTING TRACE WIRE. INSTALL UNDERGROUND WARNING TAPE
WIRE UP AND INTO CLEANOUTS AS SHOWN. USE DIRECT BURY SPLICE KITS TO
INSULATION COLOR TO MATCH THE OKIE UTILITY COLOR CODING. EXTEND TRACE
PROVIDE #12 TYPE "UF" OR "USE" SOLID COPPER TRACE WIRE INSTALLED AS SHOWN.1.
TRACE WIRE NOTE:
C-504
RESPECTIVE A.S.T.M. SPECIFICATIONS (C-478 LATEST EDITION).
ALL PRECAST COMPONENTS SHALL BE REINFORCED WITH THE
NOTE:
BACKFILLED
TRENCH HAS BEEN
SAW CUT AFTER
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 m d t.
d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
1TAPPING AN EXISTING SANITARY SEWER LINE
SPECIFICATIONS AND CONSTRUCTION DRAWINGS.
CONTRACTOR SHALL REFER TO CITY OF NORMAN STANDARD
NOTE:
N.T.S.
AND VALVE BOX.
VERTICAL PIPE BETWEEN PIPE
LOOP OF TRACE WIRE INTO
VERTICAL FOOT. PLACE A 6"
AROUND PIPE AT 3 WRAPS PER
WRAP DOUBLED TRACE WIRE
N.T.S.
2TRACE WIRE / IDENTIFICATION TAPE DETAIL
FINISHED GRADE
STAINLESS STEEL STRAPS
NEOPRENE COUPLING WITH
45° OR LESS
AS REQUIRED,
INSTALL BENDS SERVICE LINE
4" SDR 35 PVC PIPE
BASE ROCK
TYPE A AGGREGATE
ENCASE TAP WITH
TIGHT SEAL
TO PROVIDE WATER
SILICONE SEALANT
MAIN LINE
STRAPS
WITH STAINLESS STEEL
SDR 26 PVC TAPPING SADDLE
EARTH
UNDISTURBED
TAPE
IDENTIFICATION
FINISHED GRADE
(SEE NOTE 1)
TRACE WIRE
TYPICAL VALVE BOX DETAILS
BOTTOM
V A
R
IA
B L E
"4
"4
8"
"4
TOP
V A
R
IA
B L E
9"
"8
"8
"8
"4
"16
LID
WATER
"16
"4
7"
2. VALVE BOXES REQUIRING OVER 2 ADDITIONAL BOTTOM SECTIONS SHALL BE EXTENDED
NOTES:
1. WATER LINE CONTRACTOR TO PLACE 2' SQUARE CONCRETE PAD (PER NORMAN STD.)AROUND EACH
WATER VALVE AFTER FINAL GRADING HAS BEEN COMPLETED AND TRENCHES HAVE SETTLED.
USING PVC PIPE WITH A BOTTOM AND TOP SECTION PLACED ON TOP OF THE PVC PIPE.
N.T.S.
C3.5
C-505
C-505
C-505
MISCELLANEOUS DETAILS IV
6" 6"D
1'
8"
3" CL
BY THE ENGINEER.
IS SUBJECT TO REVIEW AND APPROVAL
IN PLACE DETAILED HERE. SUBSTITUTION
AS AN ALTERNATE TO THE CAST
PRECAST INLET BOX STRUCTURE
THE CONTRACTOR MAY SUBMIT A
NOTE:
(MIN.) (MIN.)
(TYP.)
(OR APPROVED EQUAL)
NEENAH NO. R-3079
FRAME & GRATE
@ 12" C/C
#4 BARS
@ 12" C/C
#4 BARS
@ 12" C/C
#4 BARS
N.T.S.
#57 OR #67 ROCK.
IF PRECAST BOX, USE 6" COMPACTED
COMPACT SUBGRADE TO 95% SPD
C-505
PIPE DIAM. MIN. TRENCH WIDTH
RECOMMENDED MINIMUM TRENCH WIDTHS
(75T AXLE LOAD) *
HEAVY CONSTRUCTION
PIPE DIAM.
SURFACE LIVE LOADING CONDITION
VECHICLE LOADING CONDITIONS
MINIMUM RECOMMENDED COVER BASED ON
H-25
NOTES:
TRENCH WIDTH
N.T.S.
BACKFILL
FINAL
BACKFILL
INITIAL
HAUNCH
BEDDING
FOUNDATION
SUITABLE
SPRINGLINE
(I F A
P P
L
IC
A B
L E
F L E
X
IB
L E P
A V
E M
E N
T
H
M
IN
C O
V E
R
(I
A
P P
L
IC
A B
L E
R
IG
ID
P
A V
E M
E N
T
H
M
IN
C O
V E
R T
O
(SEE TABLE)
MIN. TRENCH WIDTH
6" FOR 30"-60" PIPE
4" FOR 4"-24" PIPE
60"
54"
48"
42"
36"
30"
24"
18"
15"
12"
10"
8"
6"
4"
96"
88"
80"
72"
64"
56"
48"
39"
34"
30"
28"
26"
23"
21"
24"
12"
60"
48"
54" - 60"
12" - 48"
C-505
FABRIC
FILTER
TAPE
IDENTIFICATION
PRECAST INLET BOX STRUCTURE
STORM SEWER INSTALATION DETAIL PLASTIC PIPE
PROCTOR DENSITY ASTM D 698.
3. UNDER PAVEMENT FINAL & INITIAL BACKFILL TO 95% STANDARD
2. NONTRAFFIC FINAL & INITIAL BACKFILL TO 90% STANDARD PROCTOR DENSITY.
1. PROVIDE BEDDING IN ACCORDANCE WITH THE SPECIFICATIONS.
REQUIRE ADDITIONAL COVER
* VEHICLES IN EXCESS OF 75T MAY
1.4 SQ. FOOT GRATE OPENING.
OF PRECAST SHOWN HERE. SUBSTITUTE GRATES SHALL HAVE A MINIMUM
MAY SUBSTITUTE NYLO PLAST-ADS GRATES AND STRUCTURES IN PLACE
WHERE INLETS ARE CALLED FOR IN GRASSED AREAS THE CONTRACTOR2.
PROVIDE ISOLATION JOINT AT PAVEMENT INTERFACE W/BOX STRUCTURE.
WHEN USED IN P.C. CONCRETE PAVEMENT, APRON DOES NOT APPLY. 1.
NOTES:
DIRECTLY ABOVE ALL BURIED UTILITY LINES 12" BELOW FINISHED GRADE.
LABELED "CAUTION (NAME OF UTILITY) LINE BURIED BELOW," OR SIMILAR WORDING,
KITS TO CONNECT TO EXISTING TRACE WIRE. INSTALL UNDERGROUND WARNING TAPE
UP AND INTO CLEANOUTS, WATER VALVES ETC. AS SHOWN. USE DIRECT BURY SPLICE
INSULATION COLOR TO MATCH THE OKIE UTILITY COLOR CODING. EXTEND TRACE WIRE
PROVIDE #12 TYPE "UF" OR "USE" SOLID COPPER TRACE WIRE INSTALLED AS SHOWN.1.
TRACE WIRE / IDENTIFICATION TAPE NOTE:
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 m d t.
d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
R
E N
C H
NORMAL DITCH LINE
EXTENDED DITCH LINE
A
UNDISTURBED EARTH
EXTENDED DITCH LINE
CONCRETE
NORMAL DITCH LINE
D
D
C
B
UNDISTURBED EARTH6" SAND CUSHION 6" SAND CUSHION
TRENCH
D
D
EARTH
UNDISTURBED
TRENCH
U N
D
IS
T U
R B
E D E
A R
T H
D
CONCRETE
UNDISTURBED EARTH
J
X
6" SAND CUSHION
Y
CONCRETE
DIMENSIONS FOR CONCRETE ANCHORAGES
DIA.
PIPE
WIDTH
TRENCH 45 ° BEND 1/2 ° BEND 22 11 1/4 ° BEND TEE OR PLUG
J
2'- 1"
2'- 4"
2'- 8"
3'- 0"
Y
1'- 4"
1'- 6"
1'- 0"
2'- 0"
X
8"
10"
1'- 0"
1'- 0"
C
11"
11"
11"
11"
B
1'- 1"
1'- 2"
1'- 4"
1'- 6"
A
1'- 6"
1'- 8"
1'- 10"
2'- 0"
C
1'- 0"
1'- 0"
1'- 0"
1'- 0"
B
1'- 1"
1'- 2"
1'- 4"
1'- 6"
A
1'- 8"
1'- 10"
2'- 0"
2'- 0"
C
1'- 4"
1'- 4"
1'- 4"
1'- 4"
B
1'- 1"
1'- 2"
1'- 4"
1'- 6"
A
2'- 0"
2'- 0"
2'- 0"
2'- 0"
CONC. ANCHOR FOR PIPE FITTINGS
N.T.S.
E E
C
C
D
D
90° BENDS
SECTION C-C
PLAN
SECTION D-D
45°, 22 1/2°, 11 1/4° BENDS
PLAN
PLUGS
SECTION E-E
PLAN
6" 12"
XD
EARTH
UNDISTURBED
6" SAND CUSHION
SECTION A-A
TEES
Y
CONCRETE
D
18"
Y
TRENCH
A A
B B
PLAN
6" SAND CUSHION
D 18"
X
SECTION B-B
REINFORCING BARS
2'- 0"
CUSHION
6" SAND
D
SECTION FOR
VERTICAL BEAMS
EARTH
UNDISTURBED
EARTH
UNDISTURBED
CONTRACTOR.
AT THE EXPENSE OF THE
A TEE OR PLUG WILL BE
FURTHER THAN 18" FROM
ANY CONCRETE PLACED
CONCRETE
EARTH
UNDISTURBED
EARTH
UNDISTURBED
C307
MISCELLANEOUS DETAILS V
C-506
SYMBOL DESCRIPTION DATE APPR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
A
B
C
D
E
F
G
A
B
C
D
E
F
G
U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For
Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
OFFICE OF:
ISSUED BY
PROJECT MANAGER:
WORK REQUEST NO:
P R
IN
T D
A T
E
/2
/2
T
A \D ra w in g s \1
A -F
A A
B D
G
C -5 m d t.
d g n
AS SHOWN
RENOVATION OF BMB-15 (BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
BASE MAINTENANCE BUILDING
MIKE MILLS, AMP-400 Approver
R. KENT
OF
TYPE B
R. SEAMAN
2014-004363
AMP-400
MANAGEMENT
FACILITY
December 20, 2019
FINAL TYPE B SUBMITTAL 382
RUSSELL J.
27316
KENT
SSIONA
L
E N G
IN
E
ER
AMOHALKO
L
IC
E N S E
D
6" TO 8"
12" MIN. 12" MIN.
FLOW
8"
FLOW
PONDING HEIGHTPONDING HEIGHT
FLOW
36" HIGH MAXIMUM
STEEL OR WOOD POST
COMPACTED BACKFILL
6" X 8" TRENCH WITH
SIDE OF POST
SECURELY TO UPSTREAM
ATTACH FILTER FABRIC
WOOD POST
STEEL OR
DRAIN ROCK
" MINIMUM4
HEIGHT
STORAGE
9" MAXIMUM
NEEDED WITHOUT WIRE MESH SUPPORT
EXTRA STRENGTH FILTER FABRIC
DRAIN ROCK
" MINIMUM4
TRENCH DETAIL INSTALLATION WITHOUT TRENCHING
MIN. 6" THICK
COURSE AGGREGATE
2" - 3"
50' MIN.
SPILLWAY
WHERE GRADE EXCEEDS 2%
DIVERSION RIDGE REQUIRED
R O
A D
W A
Y A
DIVERSION RIDGE
A
' R
ROADWAY
WHEELS IF NECESSARY
SUPPLY WATER TO WASH
OF EQUIVALENT HEIGHT
GEOSYNTHETIC FABRIC BERM
ROCK BAGS, OR CONTINUOUS
FLOW
F L
O W
20' MIN.
2% OR GREATER
SEE NOTES.
RUNOFF TO BASIN AS REQUIRED.
USE ROCK BAGS TO CHANNELIZE
NOTE:
F L O
W
FLOW
GAPS ARE EVIDENT
PLACED SUCH THAT NO
ROCK BAGS MUST BE
4. ROCK BAGS OR SANDBAGS SHALL BE PLACED SUCH THAT NO GAPS ARE EVIDENT.
CRUSHED STONE THAT DRAINS INTO AN APPROVED SEDIMENT TRAP OR SEDIMENT BASIN.
3. WHEN WASHING IS REQUIRED, IT SHALL BE DONE ON AN AREA STABILIZED WITH
RIGHT-OF-WAY.
2. WHEN NECESSARY, WHEELS SHALL BE CLEANED PRIOR TO ENTRANCE ONTO PUBLIC
TRAP SEDIMENT.
REQUIRE TOP DRESSING, REPAIR AND/OR CLEANOUT OF ANY MEASURES USED TO
TRACKING OR FLOWING OF SEDIMENT ONTO PUBLIC RIGHT-OF-WAYS. THIS MAY
1. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION THAT WILL PREVENT
NOTES:
PLAN
SECTION A - A
FILTER FABRIC
SOIL AND SEED
STORM WATER POLLUTION PREVENTION
PRIOR TO COMMENCING CONSTRUCTION.
1.
2.
RUNOFF COEFFICIENT AFTER CONSTRUCTION = 0.74 AVERAGE
TOTAL AREA TO BE DISTURBED = 6.56 ACRES.
SLOPES = 0.4% - 33.0%
OKLAHOMA CITY AND O.D.E.Q. AND PAY ALL APPLICABLE FEES
PLAN INFORMATION
CONTRACTOR SHALL FILE NOTICE OF INTENT WITH CITY OF
RUNOFF COEFFICIENT BEFORE CONSTRUCTION = 0.58 AVERAGE
OR ARCHITECTURAL PLANS
OF…
This is the start of the file's text. The full file is on GovTribe.