This federal contract opportunity solicitation seeks offers to complete renovation of the Base Maintenance Building at the Mike Monroney Aeronautical Center. The successful offeror will provide all labor, supplies, equipment, material and equipment to modernize Building 15 in accordance with specifications and drawings included in solicitation number 6973GH-20-R-00062 issued by the Department of Transportation Federal Aviation Administration Non-Franchise Acquisition Services. Offerors must complete all work to upgrade the facility as detailed in the attachments to the solicitation.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Owner Architect
Set Number _________
RENOVATION OF BMB-15
(BASE MAINTENANCE BUILDING)
FEDERAL AVIATION ADMINISTRATION
6125 SW 68TH ST, OKLAHOMA CITY, OK
VOLUME 1 OF 2
FEDERAL AVIATION
ADMINISTRATION
A&E DIVISION, AMP-400
(405) 954-7552
LWPB ARCHITECTURE
5909 NW EXPRESSWAY, STE 600
OKLAHOMA CITY, OK 73132
(405) 722-7270 Job Number: 16-1335-G230E
Date: 12/20/19
MEP ENGINEER
CIVIL ENGINEER
BURNS & MCDONNELL
615 N HUDSON, STE 200
OKLAHOMA CITY, OK 73102
(405) 200-0306
KFC ENGINEERING
525 CENTRAL PARK DRIVE, STE 202
OKLAHOMA CITY, OK 73105
(405) 528-4596
MACARTHUR ASSOCIATED CONSULTANTS
25 NW 146TH ST
EDMOND, OK 73013
(405) 848-2471
STRUCTURAL ENGINEER
12/20/19
MATERIALS LEGEND SYMBOLS LEGEND ABBREVIATIONS
COMPLETE LISTING OF MATERIALS ON THE JOB.
STANDARD AND ARE NOT INTENDED AS A
NOTE: ABOVE MATERIAL INDICATIONS ARE
( DISCONTINUOUS MEMBER )
( CONTINUOUS MEMBER )
MISCELLANEOUS METAL
RIGID INSULATION BOARD
EARTH FILL
BATT INSULATION
ALUMINUM
FINISH WOOD
WOOD BLOCKING
WOOD FRAMING
INSULATED PANEL
PLYWOOD
LARGER SCALE DETAIL MARK
WALL SECTION CUT MARK
BUILDING SECTION CUT MARK
STRUCTURAL GRID COORDINATES
DOOR NUMBER
SQUARE CONCRETE COLUMN
WIDE FLANGE STEEL COLUMN
SQUARE STEEL COLUMN
ROUND STEEL COLUMN
FRAME PARTITION ( METAL STUD )
CONCRETE BLOCK
FOR PLANS AND DETAILS
GYPSUM BOARD
CONCRETE
FACE BRICK
EXISTING BUILDING TO BE MODIFIED
EXISTING BUILDING TO BE REMOVED
EXISTING BUILDING TO REMAIN
BENCHMARK / SPOT ELEVATION
FINISH GRADE CONTOUR
EXISTING TREE TO BE PROTECTED
EXISTING GRADE CONTOUR
EXISTING TREE TO BE REMOVED
PROPERTY LINE
PAVING ( CONCRETE )
PAVING ( ASPHALT )
CONCRETE WALK
TEST HOLE
NEW BUILDING
FENCE X X
15' OAK
18' ELM
EXISTING SPOT ELEVATION
FINISH SPOT ELEVATION
100.25
X
FRAME ELEVATION
PARTITION TYPE
ROOM NAME AND NUMBER
INTERIOR
ELEVATION REF.
1 SIM
A102 A103
DETAIL SECTION CUT MARK
Room name
1t
NORTH ARROW SYMBOLS
PLAN
NORTH
TRUE
NORTH
FOR DETAILS
SHEET WHERE
ELEV IS DRAWN
ELEV INDICATED
A5.1
EXTERIOR
ELEVATION REF.SHEET WHERE
ELEV IS DRAWN
ELEV INDICATED
A5.1
REF. CASEWORK
SECTION SHEETS
CASEWORK
SECTION
IDENTIFICATION
NUMBER512
1i
AB ABOVE
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
APPROX, APP APPROXIMATELY
ATFP, AT/FP ANTI-TERRORISM/FORCE PROTECTION
AWC ACOUSTICAL WALL COVERING
BLDG BUILDING
BM BENCH MARK
BRG BEARING
BTM BOTTOM
C CENTERLINE
CJ CONTROL JOINT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DTL DETAIL
DWR DRAWER
EJ, EXP JT EXPANSION JOINT
ELEC ELECTRICAL
ELEV ELEVATION
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXIST, EXSTG EXISTING
EXT, EXTR EXTERIOR
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEB FIRE EXTINGUISHER BRACKET
FEC FIRE EXTINGUISHER CABINET
FF, FIN FLR FINISH FLOOR
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIO FOR INFORMATION ONLY
F FLOW LINE
GA GAUGE
GI GALVANIZED IRON
GWB, GYP BD GYPSUM BOARD
HC, HDCP HANDICAPPED (ACCESSIBLE)
HD HEAD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
INSUL INSULATION
INT, INTR INTERIOR
JST JOIST
JT JOINT
LAM LAMINATE
LAV LAVATORY
LP LIGHT POLE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MECH MECHANICAL
MFR, MFG MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OPNG OPENING
OPP OPPOSITE
PL PLATE
PLYWD PLYWOOD
R RADIUS OR RISER
RE:, REF REFER
REINF REINFORCING / REINFORCED
REQD REQUIRED
RI ROUGH IN
RM ROOM
RO ROUGH OPENING
SB SMART BOARD
SC SOLID CORE
SCHED SCHEDULE / SCHEDULED
SIM SIMILAR
SJ SCORED JOINT
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STL STEEL
STRUCT STRUCTURAL
T TREAD
TB TACK BOARD
TOC TOP OF CURB
TOM TOP OF MASONRY
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VERT VERTICAL
WC WATER CLOSET
WD WOOD
L
L
SHEET WHERE DETAIL IS
DRAWN
DETAIL INDICATED
SHEET WHERE DETAIL
IS FIRST REFERENCED
EXISTING WALL
GYPSUM SHEATHING
SIM
A102A108
SIM
A102A108
SIM
A102A108
SIM
A102A108
NOTE: ADDITIONAL SYMBOLS/ABBREVIATIONS NOT SHOWN OR DEFINED WITHIN THIS SHEET MAY OCCUR AND ARE DEFINED ON OTHER DRAWINGS.
-/--- SHEET WHERE
VIEW IS DRAWN
VIEW INDICATED
3-DIMENSIONAL
ISOMETRIC VIEW REF.
3-DIMENSIONAL CAMERA/
PERSPECTIVE VIEW REF.
GENERAL
DIRECTION OF
VIEW
SHEET WHERE
VIEW IS DRAWN
VIEW INDICATED
GENERAL
DIRECTION OF
VIEW
3-DIMENSIONAL
ISOMETRIC NORTH
ARROW SYMBOL
PLAN
NORTH
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT SCALE:
DRAWING NO. AMP-400-E-
OF
LO
C
AL
F
IL
E:
PL
O
T D
AT
E:
LW
PB
J O
B N
O
C
EN
TR
AL
F
SIGNATURES AFFIXED BELOW INDICATE OFFICIAL
RECOMMENDATION AND APPROVAL OF ALL
DRAWINGS IN THIS SET AS INDEXED ON THIS SHEET
REVIEWED BY:
APPROVED BY:
TITLE: CHIEF, DESIGN BRANCH
TITLE: CHIEF, ENGR & CONST DIV. DATE: 382
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
PL
AT
E:
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY
MANAGEMENT
AMP-400
PROJECT MANAGER:
WORK REQUEST NO:
BASE MAINTENANCE BUILDING
PLOT DATE:
12/20/19
12" = 1'-0"
BI
M
FA
A M
M
AC
B as e M ai nt en an ce B ui ld in g/
M M
AC
-B
M B
R en ov at io n
Ty pe
B -A rc h.
rv t
/2
0/
:2 6:
P
M
12/20/2019 3:26:40 PM
RENOVATION OF BMB-15
(BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
VOLUME 1 DRAWING INDEX,
SYMBOLS AND ABBREVIATIONS
G-001BW
BW
2014-004363
-1
5-
G
0E
\\l w pb -fi le sr vr \F ed er al
FA
A\
FA
A
ID
IQ
\T O
B M
B R en ov at io n Ty pe B
\0
D w gs \0
Ar ch M
M
AC
-B M
B R en ov at io n Ty pe B
7.
rv t
LW
PB
0 1
6.
0 2
12/20/19
MONTE THURMAN,
AMP-400
2014-004363
MONTE THURMAN,
AMP-400
DRAWING INDEX - VOLUME 1
NUM NAME
STRUCTURAL
S-100 GENERAL NOTES
S-101 GENERAL NOTES
S-102 TYPICAL CONCRETE DETAILS
S-103 TYPICAL CONCRETE DETAILS
S-104 TYPICAL STEEL DETAILS
S-105 SPECIAL INSPECTIONS
S-200 FOUNDATION PLAN - OVERALL
S-201 FOUNDATION PLAN - AREA A
S-202 FOUNDATION PLAN - AREA B
S-203 FOUNDATION PLAN - AREA C
S-204 FOUNDATION PLAN - AREA D
S-300 FRAMING PLAN - OVERALL
S-301 FRAMING PLAN - AREA A
S-302 FRAMING PLAN - AREA B
S-303 FRAMING PLAN - AREA C
S-304 FRAMING PLAN - AREA D
S-310 SHELTER ROOF FRAMING PLAN
S-401 FRAMING ELEVATIONS AND DETAILS
S-402 FRAMING ELEVATIONS AND DETAILS
S-403 FRAMING ELEVATIONS AND DETAILS
S-410 CANOPY DETAILS
S-501 FOUNDATION DETAILS
S-601 FRAMING SECTIONS
S-602 FRAMING SECTIONS
S-603 FRAMING SECTIONS
DRAWING INDEX - VOLUME 1
NUM NAME
A-220 FLOOR PLAN - OVERALL - PHASE 2
A-221 FLOOR PLAN - AREA A - PHASE 2
A-222 FLOOR PLAN - AREA B - PHASE 2
A-300 CEILING PLAN - BASEMENT - PHASE 1
A-310 CEILING PLAN - OVERALL - PHASE 1A
A-313 CEILING PLAN - AREA C - PHASE 1A
A-314 CEILING PLAN - AREA D - PHASE 1A
A-315 CEILING PLAN - OVERALL - PHASE 1B
A-317 CEILING PLAN - AREA B - PHASE 1B
A-318 CEILING PLAN - AREA C - PHASE 1B
A-320 CEILING PLAN - OVERALL - PHASE 2
A-321 CEILING PLAN - AREA A - PHASE 2
A-322 CEILING PLAN - AREA B - PHASE 2
A-340 ENLARGED CEILING PLANS
A-410 ROOF PLAN - OVERALL - PHASE 1
A-420 ROOF PLAN - OVERALL - PHASE 2
A-440 TYPICAL ROOF DETAILS
A-510 ELEVATIONS - OVERALL - PHASE 1
A-511 ENLARGED BUILDING ELEVATIONS - PHASE 1
A-520 ELEVATIONS - OVERALL - PHASE 2
A-521 ENLARGED BUILDING ELEVATIONS - PHASE 2
A-522 ENLARGED BUILDING ELEVATIONS - PHASE 2
AE101 DOOR SCHEDULE
AE102 DOOR DETAILS
AE201 DOOR & FRAME ELEVATIONS
AE202 FRAME ELEVATIONS
AE203 FRAME ELEVATIONS
AE601 INTERIOR PARTITION TYPES
AE602 INTERIOR PARTITION TYPES
AE611 WALL SECTIONS
AE612 WALL SECTIONS
AE613 WALL SECTIONS
AE614 WALL SECTIONS
AE615 WALL SECTIONS
AE616 WALL SECTIONS
AE617 WALL SECTIONS
AE618 WALL SECTIONS
AE701 ENLARGED PLANS & ELEVATIONS (PHASE 1)
AE702 ENLARGED PLANS & ELEVATIONS (PHASE 1)
AE703 ENLARGED PLANS & ELEVATIONS (PHASE 2)
AE704 INTERIOR ELEVATIONS (PHASE 2)
AE705 INTERIOR ELEVATIONS (PHASE 2)
AE706 INTERIOR ELEVATIONS (PHASE 2)
AE707 INTERIOR MILLWORK AND DETAILS
AE708 INTERIOR MILLWORK AND DETAILS
AE709 INTERIOR MILLWORK AND DETAILS
AE801 PLAN DETAILS
AE802 PLAN DETAILS
AE803 PLAN DETAILS
AE804 PLAN DETAILS
AE901 VERTICAL DETAILS
AE902 VERTICAL DETAILS
AE903 VERTICAL DETAILS
AE930 CEILING DETAILS
AE931 CEILING DETAILS
AF112 INTERIOR FINISHES & SPECIALTIES - AREA B (PHASE 1)
AF113 INTERIOR FINISHES & SPECIALTIES - AREA C (PHASE 1)
AF121 INTERIOR FINISHES & SPECIALTIES - AREA A (PHASE 2)
AF122 INTERIOR FINISHES & SPECIALTIES - AREA B (PHASE 2)
AF600 INTERIOR FINISH LEGEND
AF601 INTERIOR FINISH LEGEND
AF602 INTERIOR FINISH SCHEDULES
AF603 INTERIOR FINISH SCHEDULES
AG112 SIGNAGE PLAN -AREA B (PHASE 1)
AG113 SIGNAGE PLAN -AREA C (PHASE 1)
AG121 SIGNAGE PLAN -AREA A (PHASE 2)
AG122 SIGNAGE PLAN -AREA B (PHASE 2)
AG601 SIGNAGE DETAILS
INTERIORS
IF112 FURNITURE PLAN - AREA B (PHASE 1)
IF113 FURNITURE PLAN - AREA C (PHASE 1)
IF121 FURNITURE PLAN - AREA A (PHASE 2)
IF122 FURNITURE PLAN - AREA B (PHASE 2)
DRAWING INDEX - VOLUME 1
NUM NAME
GENERAL
G-000 VOLUME 1 COVER SHEET
G-001 VOLUME 1 DRAWING INDEX, SYMBOLS AND ABBREVIATIONS
G-002 GENERAL NOTES AND DIMENSIONING CONVENTIONS
G-003 MOUNTING HEIGHTS, LOCATIONS AND CONFIGURATIONS
G-004 ACCESSIBILITY REQUIREMENTS
G-100 LIFE SAFETY INFORMATION
G-101 LIFE SAFETY PLAN
G-102 LIFE SAFETY PLAN
G-103 LIFE SAFETY PLAN
G-104 LIFE SAFETY PLAN
G-105 LIFE SAFETY PLAN
G-201 TORNADO SHELTER REQUIREMENTS
G-301 AIR BARRIER PLAN
G-302 AIR BARRIER SECTIONS
GC101 EXISTING FUNCTIONAL LAYOUT
GC102 PHASE 1A (INTERIM FUNCTIONAL LAYOUT)
GC103 PHASE 1B (INTERIM FUNCTIONAL LAYOUT)
GC104 PHASE 2 (INTERIM FUNCTIONAL LAYOUT)
GC105 PHASE 2 (COMPLETE FUNCTIONAL LAYOUT)
CIVIL
C-001 GENERAL NOTES & CIVIL LEGEND
V-101 SURVEY DATA SHEET
CD101 DEMOLITION PLAN
C-101 OVERALL SITE LAYOUT PLAN
C-102 SITE LAYOUT PLAN
C-103 UTILITY LAYOUT PLAN
C-104 GRADING PLAN
C-105 JOINT LAYOUT SHEET
C-106 SANITARY SEWER PLAN & PROFILE
C-107 STORM WATER MANAGEMENT PLAN
C-108 EROSION CONTROL PLAN
C-501 PAVING JOINT DETAILS
C-502 TYPICAL PAVEMENT SECTIONS AND MISCELLANEOUS DETAILS
C-503 MISCELLANEOUS DETAILS II
C-504 MISCELLANEOUS DETAILS III
C-505 MISCELLANEOUS DETAILS IV
C-506 MISCELLANEOUS DETAILS V
C-507 EROSION CONTROL DETAILS
C-508 CONCRETE WASHOUT DETAIL
C-509 ADA CURB RAMP DETAILS
ARCHITECTURAL
AD100 ARCHITECTURAL DEMOLITION NOTES & EXSTG EQPMT SCHED
AD200 DEMOLITION FLOOR PLAN - BASEMENT - PHASE 1
AD210 DEMOLITION FLOOR PLAN - OVERALL - PHASE 1A
AD213 DEMOLITION FLOOR PLAN - AREA C - PHASE 1A
AD214 DEMOLITION FLOOR PLAN - AREA D - PHASE 1A
AD215 DEMOLITION FLOOR PLAN - OVERALL - PHASE 1B
AD217 DEMOLITION FLOOR PLAN - AREA B - PHASE 1B
AD218 DEMOLITION FLOOR PLAN - AREA C - PHASE 1B
AD220 DEMOLITION FLOOR PLAN - OVERALL - PHASE 2
AD221 DEMOLITION FLOOR PLAN - AREA A - PHASE 2
AD222 DEMOLITION FLOOR PLAN - AREA B - PHASE 2
AD300 DEMOLITION CEILING PLAN - BASEMENT - PHASE 1
AD310 DEMOLITION CEILING PLAN - OVERALL - PHASE 1A
AD313 DEMOLITION CEILING PLAN - AREA C - PHASE 1A
AD314 DEMOLITION CEILING PLAN - AREA D - PHASE 1A
AD315 DEMOLITION CEILING PLAN - OVERALL - PHASE 1B
AD317 DEMOLITION CEILING PLAN - AREA B - PHASE 1B
AD318 DEMOLITION CEILING PLAN - AREA C - PHASE 1B
AD320 DEMOLITION CEILING PLAN - OVERALL - PHASE 2
AD321 DEMOLITION CEILING PLAN - AREA A - PHASE 2
AD322 DEMOLITION CEILING PLAN - AREA B - PHASE 2
AD410 DEMOLITION ROOF PLAN - OVERALL - PHASE 1
AD420 DEMOLITION ROOF PLAN - OVERALL - PHASE 2
AD510 DEMOLITION ELEVATIONS - OVERALL - PHASE 1
AD520 DEMOLITION ELEVATIONS - OVERALL - PHASE 2
A-100 ARCHITECTURAL SITE PLAN
A-101 ARCHITECTURAL SITE DETAILS - BASE BID
A-102 ARCHITECTURAL SITE DETAILS - OPT. NO. 1 NORTH CANOPY
A-103 ARCHITECTURAL SITE DETAILS - OPT. NO. 2 WEST CANOPY, ETC.
A-104 ARCHITECTURAL SITE DETAILS
A-200 FLOOR PLAN - BASEMENT - PHASE 1
A-210 FLOOR PLAN - OVERALL - PHASE 1A
A-213 FLOOR PLAN - AREA C - PHASE 1A
A-214 FLOOR PLAN - AREA D - PHASE 1A
A-215 FLOOR PLAN - OVERALL - PHASE 1B
A-217 FLOOR PLAN - AREA B - PHASE 1B
A-218 FLOOR PLAN - AREA C - PHASE 1B
SYMBOL DESCRIPTION DATE APPR
1. ORIGINAL TOPOGRAPHIC SURVEY BY TERRACON AND PROVIDED TO ARCHITECT.
2. AN ATTEMPT HAS BEEN MADE TO LOCATE AND SHOW ON THE DRAWINGS EXISTING
UNDERGROUND UTILITIES AND OTHER EXISTING SITE CONDITIONS, HOWEVER, THE
CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING THE SITE AND VERIFYING ALL
EXISTING UTILITIES AND CONDITIONS AT THE SITE PRIOR TO THE START OF
CONSTRUCTION, AND SHALL REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR
CLARIFICATION BEFORE PROCEEDING WITH THE WORK.
3. COMPREHENSIVE INSPECTIONS AND SURVEYS HAVE BEEN PERFORMED TO IDENTIFY
ASBESTOS CONTAINING MATERIAL (ACM) IN THIS BUILDING, AND THE FAA WILL PERFORM A
THOROUGH PRE-BID INSPECTION OF THE AREAS THAT WILL BE IMPACTED BY THIS
PROJECT. THE FAA WILL SECURE AN ABATEMENT CONTRACTOR VIA MMAC CONTRACTING
FOR ALL KNOWN AND YET TO BE IDENTIFIED ACM. FOR THE MOST PART, ABATEMENT WILL
BE COORDINATED WITH THE CONSTRUCTION CONTRACTOR’S WORK SCHEDULE AND
COMPLETED PRIOR TO THE CONSTRUCTION CONTRACTOR’S MOBILIZATION.
NEVERTHELESS ACM MAY STILL BE ENCOUNTERED DURING DEMOLITION/RENOVATION
ACTIVITIES. IF ACM IS ENCOUNTERED OR SUSPECTED DURING CONSTRUCTION ACTIVITIES,
THE CONTRACTOR SHOULD STOP WORK IN THAT AREA AND CONTACT THE FAA PROJECT
MANAGER FOR FURTHER INSTRUCTION. IF SAMPLING IS PERFORMED AND THE RESULTS OF
THE ANALYSIS INDICATE THAT MITIGATION IS REQUIRED, THE FAA WILL PROCURE AN
ABATEMENT CONTRACTOR TO COMPLETE THIS TYPE OF WORK.
4. LEAD-BASED PAINT HAS BEEN IDENTIFIED IN THIS BUILDING. THE GENERAL CONTRACTOR
SHALL BE RESPONSIBLE FOR, AND SHALL INCLUDE IN THEIR PROPOSED BID, ALL COSTS
ASSOCIATED WITH ANY NECESSARY LEAD MITIGATION OR REMEDIATION PLANS, PERMITS,
ACTIONS AND ACTIVITIES.
5. HAZARDOUS MATERIALS INCLUDING, BUT NOT LIMITED TO, ASBESTOS, MATERIALS
CONTAINING ASBESTOS (ACM), LEAD, POLYCHLORINATED BIPHENYL (PCB) OR OTHER
TOXIC SUBSTANCES SHALL NOT BE CONTAINED IN MATERIALS AND/OR PRODUCTS USED IN
THE CONSTRUCTION OF THIS PROJECT.
6. CONSTRUCTION STAGING AREA & VEHICLE ACCESS SHALL BE CONFIRMED WITH OWNER,
AND CONSTRUCTION MANAGER IF APPLICABLE, PRIOR TO CONSTRUCTION.
7. FINISH GRADE AT BUILDING PERIMETERS SHALL BE 6" BELOW FINISH FLOOR UNLESS
SPECIFICALLY NOTED OTHERWISE ON CIVIL DRAWINGS. DEVELOP POSITIVE DRAINAGE
AWAY FROM NEW AND/OR EXISTING BUILDING(S).
8. ALL AREAS OF THIS SITE, WHICH ARE NOT IN THE SCOPE OF THE PROJECT AND ARE
DISTURBED BY CONSTRUCTION SHALL BE RETURNED TO ORIGINAL CONDITION.
9. ALL GRID LINES IDENTIFIED BY A LETTER OR NUMBER ARE PARALLEL UNLESS OTHERWISE
NOTED.
10. CONTRACTOR SHALL VERIFY ALL COLUMN COORDINATES AND CHECK THEM AGAINST
DIMENSIONS SHOW ON PLANS AND DETAILS. NOTIFY ARCHITECT OF ANY DISCREPENCY
DURING STAKING.
11. SIZES OF HOUSEKEEPING PADS AND BASES FOR MECHANICAL EQUIPMENT ARE
APPROXIMATE. CONTRACTOR SHALL VERIFY EXACT LOCATION AND REQUIRED SIZE OF ALL
CONCRETE PADS AND BASES WITH EQUIPMENT MANUFACTURERS BEFORE POURING. ALL
PADS TO BE PROVIDED BY THE CONTRACTOR.
12. ALL METAL STUDS WALLS WHERE PLUMBING OCCURS OR STRUCTURAL COLUMNS ARE
LOCATED SHALL BE MINIMUM 6" METAL STUDS. NOTIFY ARCHITECT OF ANY
DISCREPANCIES OR CONFLICTS.
13. PROVIDE AND INSTALL ACCESS PANELS, WHERE REQUIRED BY BUILDING CODE OR FOR
THE PROPER OPERATION OF MECHANICAL OR ELECTRICAL EQUIPMENT, AND AS SHOWN
ON THE DRAWINGS. CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND TYPE OF
ACCESS PANEL WITH OTHER CONTRACTORS' WORK AND RECEIVE APPROVAL OF THE
ARCHITECT. ACCESS PANEL SHALL BE AS SPECIFIED.
14. 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING 8'-0" HIGH SHALL BE PROVIDED AND
INSTALLED ON ALL WALLS OF TELEPHONE, COMMUNICATIONS, SYSTEMS AND ELECTRICAL
ROOMS AS REQUIRED UNLESS SPECIFICALLY SHOWN OTHERWISE ON ELECTRICAL
DRAWINGS.
15. ALL WOOD WITHIN THIS PROJECT (I.E. PLYWOOD, BLOCKING, ETC.) SHALL BE FIRE-
RETARDANT TREATED.
16. FOR ILLUSTRATION AND DEFINITION OF TYPICAL SYMBOLS USED ON THE ARCHITECTURAL
DRAWINGS, SEE “SYMBOLS AND ABBREVIATIONS” SHEET. ADDITIONAL SYMBOLS NOT
SHOWN OR DEFINED THERE MAY OCCUR AND ARE DEFINED ON OTHER DRAWINGS.
17. DO NOT SCALE THE DRAWINGS.
18. REFER TO SPECIFICATIONS FOR ADDITIONAL PAINT ITEMS NOT SHOWN ON ROOM FINISH
SCHEDULE OR PLANS.
19. IN THE CASE OF A CONFLICT BETWEEN THE DRAWINGS AND SPECIFICATIONS, THE MORE
RESTRICTIVE AND/OR EXPENSIVE OF THE TWO SHALL TAKE PRECEDENCE. CONTRACTOR
SHALL NOTIFY THE ARCHITECT OF ANY CONFLICT BEFORE PROCEEDING WITH THE WORK.
20. THE SPECIFICATIONS AND ALL CONSULTANT DRAWINGS ARE SUPPLEMENTAL TO THE
ARCHITECTURAL DRAWINGS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
COORDINATE WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF ANY
OF THE CONSULTANTS' WORK AND TO BRING ANY DISCREPANCIES OR CONFLICTS TO THE
ARCHITECT'S ATTENTION FOR CLARIFICATION. IMPROPERLY INSTALLED WORK SHALL BE
CORRECTED BY THE CONTRACTOR AT NO EXPENSE TO THE ARCHITECT, HIS
CONSULTANTS, OR THE OWNER.
21. ALL ITEMS WITHIN THESE PROJECT DOCUMENTS ARE PART OF THE BASE BID UNLESS
OTHERWISE NOTED.
GENERAL NOTES:
22. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS
WHICH, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF
DRAWINGS. THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY
BE AFFECTED BY THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE
AND MAY REQUIRE REFERENCE TO DRAWINGS OF ANOTHER DISCIPLINE. PARTIAL
SETS OF DRAWINGS SHALL NOT BE DISTRIBUTED AND UTILIZED BY THE
CONTRACTOR. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND
COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH
THE REQUIREMENTS OF THE CONTRACT BEFORE COMMENCING CONSTRUCTION AND
TO ASSURE THAT ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS
OF WHERE THE REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS.
23. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND
ELEVATIONS SHOW THE EXACT LOCATION OF MANY, BUT NOT ALL, EXPOSED PARTS
OF THE WORK. FOR TYPICAL DIMENSIONING CONVENTIONS, INCLUDING RULES FOR
LOCATING DOORS AND OTHER ITEMS WHICH HAVE NOT BEEN DIMENSIONED OR
LOCATED EXACTLY, APPLY THE RULES INDICATED BY THE "RULES AND
CONVENTIONS" SHEET TO DETERMINE THE EXACT LOCATION OF EACH EXPOSED
PART OF THE WORK..
24. THE ARCHITECTURAL DRAWINGS ESTABLISH AND COORDINATE THE FINISHED
APPEARANCE OF ALL EXPOSED ELEMENTS OF THE WORK, INCLUDING THAT WORK
WHICH IS ILLUSTRATED PRIMARILY ON DRAWINGS OF OTHER DISCIPLINES.
LOCATIONS SHOWN ON OTHER DRAWINGS ARE SCHEMATIC, UNLESS OTHERWISE
NOTED ON THE ARCHITECTURAL DRAWINGS. THE ARCHITECTURAL DRAWINGS TAKE
PRECEDENCE FOR THE FINISHED APPEARANCE AND EXACT LOCATION OF ALL PARTS
OF THE WORK. [EXCEPTIONS: DIMENSIONED LOCATIONS SHOWN ON DRAWINGS OF
OTHER DISCIPLINES SHALL GOVERN ONLY WHERE: (A) SPECIFICALLY AND
INDIVIDUALLY INDICATED BY SYMBOL, KEYED NOTE, OR NOTATION ON THE
ARCHITECTURAL DRAWINGS. (B) OCCURRING WITHIN A ROOM OR OTHER IDENTIFIED
SPACE FOR WHICH ARCHITECTURAL SHEET OR SCHEDULE NOTES INDICATE THAT
DIMENSIONS PROVIDED ELSEWHERE SHALL GOVERN.]
25. CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE VARIOUS TRADE
ITEMS WITHIN THE SPACE ABOVE THE CEILINGS (INCLUDING, BUT NOT LIMITED TO
STRUCTURAL MEMBERS AND SPRAY-ON INSULATION OR FIREPROOFING,
MECHANICAL DUCTS AND BATT INSULATION, CONDUITS, RACEWAY, SPRINKLER
SYSTEMS, LIGHT FIXTURES, CEILING SYSTEMS, AND ANY SPECIAL STRUCTURAL
SUPPORTS REQUIRED) AND SHALL BE RESPONSIBLE FOR MAINTAINING THE FINISH
CEILING HEIGHT ABOVE THE FINISH FLOOR INDICATED IN THE DRAWINGS AND FINISH
SCHEDULE.
26. PROVIDE FIRE EXTINGUISHERS WITH A RATING OF NOT LESS THAN 2A WITHIN 75
FOOT TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING. PROVIDE PORTABLE
FIRE EXTINGUISHERS AS THE BUILDING IS CONSTRUCTED.
ARCHITECTURAL DIMENSIONING CONVENTIONS
1. EXCEPT WHERE DIRECTED TO PLACE ITEMS OF THE WORK
AT THE "APPROXIMATE LOCATION SHOWN," DO NOT SCALE
THE DRAWINGS FOR DIMENSIONAL INFORMATION.
2. ALL ELEMENTS OF THE DRAWINGS MAY NOT BE DRAWN TO
EXACT SCALE. ALL DIMENSIONS REQUIRED ARE SHOWN (OR
MAY BE DERIVED FROM THOSE SHOWN OR NOTED) ONT HE
FLOOR PLANS, DETAIL PLANS, ELEVATIONS, SECTIONS,
SCHEDULES, CONFIGURATION DETAILS AND
SPECIFICATIONS. SEE THE NOTES BELOW AND "SYMBOLS
AND ABBREVIATIONS" SHEET FOR DIMENSIONING, GRAPHIC
AND OTHER TYPICAL CONVENTIONS USED ON THIS
PROJECT.
3. EXCEPT WHERE SPECIFICALLY NOTED TO THE CONTRARY,
ALL DIMENSIONS SHOWN ON THE ARCHITECTURAL
DRAWINGS CONFORM TO THE FOLLOWING CONVENTIONS:
• FINISH FACES AT THE MOST NARROW OR CONSTRICTED
POINT OF SECTION WHERE DIMENSION IS SHOWN, WHEN
THE DIMENSION OCCURS ACROSS AN OPEN SPACE. IN
THIS CASE, A "FACE OF FINISH" DIMENSION IS
EQUIVALENT TO A "CLEAR" DIMENSION.
• FINISH FACES AT THE WIDEST OR MOST EXPANSIVE
POINTS OF THE SECTION THE DIMENSION IS SHOWN
WHEN THE DIMENSION OCCURS ACROSS AN OBJECT OR
GROUP OF OBJECTS.
• EDGE OF THE INDICATED CEILING AT THE FACE OF THE
ADJACENT APPLIED FINISH, MEASURED AT THE PLANE OF
THE CEILING.
• CAUTION: DUE TO THE POSSIBLE APPLICATION OF APPLIED
FINISHES (THE THICKNESS OF WHICH MAY VARY BETWEEN
FLOOR AND CEILING AND IS NOT ACCOUNTED FOR BY THE
DIMENSIONS SHOWN ON THE FLOOR PLANS, EXCEPT AS
INDICATED BY "FACE OF FINISH" OR "CLEAR"), THE
CONTRACTOR MUST ADJUST, AS NECESSARY, THE FLOOR
PLAN DIMENSIONS TO REFLECT THE ACTUAL DIMENSIONS
FOUND AT THE PLANE OF THE CEILING.
4. WHERE WALLS AND/OR PARTITIONS OF UNEQUAL
THICKNESS ABUT, ALIGN EXPOSED FACES, UNLESS
OTHERWISE NOTED.
5. WHERE DIMENSIONS ARE NOT PROVIDED ON FLOOR
PLANS TO LOCATE DOOR OPENINGS, APPLY THE
FOLLOWING RULES IN ORDER, TO DETERMINE THE
LOCATION OF DOOR OPENINGS:
• AT DOORS OCCURRING IN WALLS OF CONCRETE
OR CONCRETE MASONRY CONSTRUCTION, LOCATE
THE HINGE-SIDE OF THE DOOR FINISHED OPENING
10 INCHES FROM THE FACE (EXCLUSIVE OF
APPLIED FINISHES) OF THE CLOSEST
PERPENDICULAR WALL OR PARTITION ASSEMBLY.
MEASURED AT CLG PLANE
"EQUAL" DIM AT CEILING
MEASURED TO FACE OF PTN
TYP. DIM ON CEILING PLAN
4".
4".
ALIGN
10".
10".
A. GENERALLY, DIMENSIONS ARE MEASURED TO:
• STRUCTURAL OR DIMENSIONAL GRID LINES.
• CENTERLINE OF STUD (EXCLUSIVE OF GWB, AND
ANY APPLIED FINISHES HAVING THICKNESS WHICH
MAY BE ADDED TO SUCH WALLS) AT PARTITIONS
FRAMED WITH METAL STUDS. REFER TO
"PARTITION TYPES" SCHEDULE TO DETERMINE
THICKNESS OF EACH PARTITION TYPE.
• FACE OF CONCRETE OR MASONRY WALL
(EXCLUSIVE OF ANY FURRING OR APPLIED FINISHES
HAVING THICKNESS WHICH MAY BE ADDED TO SUCH
WALLS) AT WALLS WITH CONCRETE OR MASONRY
COMPONENTS. REFER TO STRUCTURAL DRAWINGS
AND "PARTITION TYPES" SCHEDULE TO DETERMINE
THICKNESS OF EACH PARTITION TYPE.
• FACE OF APPLIED FINISH IF NOTED AS A "FACE OF
FINISH" OR "CLEAR" DIMENSION. SEE NOTE 'B'
BELOW.
• OUTSIDE EDGE OF HOLLOW METAL DOOR AND
WINDOW FRAMES. REFER TO THE "DOOR
SCHEDULE" AND "FRAME ELEVATIONS" FOR
ADDITIONAL DIMENSIONAL INFORMATION.
• INSIDE EDGE OF FINISHED WALL OPENING AT
OTHER DOORS, WINDOWS AND CURTAIN WALLS.
REFER TO THE "DOOR SCHEDULE" AND "FRAME
ELEVATIONS" FOR ADDITIONAL DIMENSIONAL
INFORMATION.
• DIMENSION OR WORK POINTS AS INDICATED ON
RELATED ARCH DETAIL, PLAN, SECTION,
ELEVATION, LAYOUT OR CONFIGURATION DETAIL,
OR CONSTRUCTION DETAIL.
B. WHERE "FACE OF FINISH" OR "CLEAR" DIMENSIONS ARE
SPECIFICALLY NOTED, THE DIM IS MEASURED TO:
C. WHERE "EQUAL" DIMENSIONS ARE USED:
• IN CASEWORK AND OTHER SUCH ELEMENTS, "EQUAL"
DIMENSIONS ARE NOT INTENDED TO REQUIRE CUSTOM
COMPONENTS. SUCH "EQUAL" ELEMENTS SHALL BE THE
SAME SIZE, AT THE STANDARD SIZE INCREMENT THAT
MOST NEARLY EQUALS THE DESIGNED OVERALL
DIMENSION. IN THESE CONDITIONS, EQUAL SIZE FILLER
PANELS ARE INTENDED AND REQUIRED AT EACH END OF
THE RUN.
D. WHERE "EQUAL" DIMENSIONS ARE USED ON REFLECTED
CEILING PLANS TO LOCATE CEILING GRID WORK POINTS,
MEASURE DIMENSIONS TO:
A. DOOR OPENINGS MAY BE DIMENSIONED ON DRAWINGS
OTHER THAN THE FLOOR PLANS. REFER TO THE
SECTIONS, ELEVATIONS, DETAILS AND DOOR SCHEDULE
NOTES FOR ADDITIONAL DIMENSIONAL INFORMATION.
B. WHERE THE HINGE-SIDE OF A DOOR IS SHOWN
ADJACENT TO A WALL, OR WALLS, PERPENDICULAR TO
THE WALL IN WHICH THE DOOR OPENING OCCURS:
• AT DOORS OCCURRING IN METAL FRAMED GYPSUM
BOARD PARTITIONS, LOCATE THE HINGE-SIDE OF
THE DOOR FINISHED OPENING 4 INCHES FROM THE
FACE (EXCLUSIVE OF APPLIED FINISHES) OF THE
CLOSEST PERPENDICULAR WALL OR PARTITION
ASSEMBLY.
C. WHERE DOOR OCCURS NOT ADJACENT TO A
PERPENDICULAR WALL, AND EITHER "DIM E" OR "DIM F"
IS 16'-0" OR LESS, LOCATE DOOR UTILIZING THE
FOLLOWING MINIMUM DIMENSIONS:
• DIM. A = 18 INCHES MIN
• DIM. B = 12 INCHES MIN
• DIM. C = DOOR WIDTH + 2 INCHES MINIMUM
• DIM. D = 4 INCHES MIN AT METAL FRAMED GYP
BD PARTITIONS
• DIMS. E AND F = AS SHOWN ON PLANS
• DIM. G = 36 INCHES MIN
• DIM. H = 60 INCHES MIN
• IF SPACE ALLOWS, CENTER DOOR IN WALL
SHOWN ON THE DRAWINGS SO THAT EITHER
"DIM A" EQUALS "DIM C", OR "DIM B" EQUALS
"DIM D".
D. IF "DIM E" IN DIAGRAMS BELOW IS LESS THAN THE
SUM OF 2 TIMES THE DOOR WIDTH PLUS 20 INCHES,
LOCATE DOOR SO THAT MINIMUMS STATED BY NOTE
4C ABOVE FOR "DIM A", "DIM B", AND "DIM D" ARE MET,
MAXIMIZING "DIM A" AND MINIMIZING "DIM D" TO THE
EXTENT POSSIBLE.
A E
C G
B D
F
H
E A
B D
E A D
B
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT DATE: PLOT SCALE:
DRAWING NO. AMP-400-E-
OF
LO
C
AL
F
T D
AT
E:
LW
PB
J O
B N
O
C
EN
TR
AL
F
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
PL
AT
E:
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY
MANAGEMENT
AMP-400
PROJECT MANAGER:
WORK REQUEST NO:
BASE MAINTENANCE BUILDING
12/20/19
12" = 1'-0"12/20/2019 3:26:42 PM
BI
M
FA
A M
M
AC
B as e M ai nt en an ce B ui ld in g/
M M
AC
-B
M B
R en ov at io n
Ty pe
B -A rc h.
rv t
/2
0/
:2 6:
P
M
RENOVATION OF BMB-15
(BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
GENERAL NOTES AND
DIMENSIONING CONVENTIONS
G-002BW
BW
2014-004363
-1
5-
G
0E
\\l w pb -fi le sr vr \F ed er al
FA
A\
FA
A
ID
IQ
\T O
B M
B R en ov at io n Ty pe B
\0
D w gs \0
Ar ch M
M
AC
-B M
B R en ov at io n Ty pe B
7.
rv t
LW
PB
0 1
6.
0 2
12/20/19
MONTE THURMAN,
AMP-400
2014-004363
MONTE THURMAN,
AMP-400
10'-6"
GRID
C
C
RULE 1 RULE 3
RULE 7
RULE 2
RULE 5 RULE 6
RULE 4
RULE 8
WHEN COMPLETELY DIMENSIONED ON PLANS NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
NOT DIMENSIONED AND LOCATED ADJ TO DOOR AND ON
WALL AGAINST WHICH DOOR SWINGS
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
NOT DIMENSIONED AND LOCATED ADJ TO MIN STRIKE-SIDE OF DOOR NOT DIMENSIONED AND LOCATED ADJACENT TO DOOR (OR WINDOW)
NOT DIMENSIONED AND LOCATED ON COLUMN OR PILASTER
WHEN NOT DIMENSIONED AND LOCATED ADJACENT TO
CHANGE IN WALL DIRECTION
NON-TYPICAL MOUNTING HEIGHTS MAY BE INDICATED BY SYMBOL (AS
SHOWN), BY KEYED NOTE, OR BY NOTATION ON PLANS.
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR PILASTER, AND WHEN
NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES: HORIZONTALLY CENTER GROUP
OF SIMILAR ITEMS HAVING THE SAME MOUNTING HEIGHT(S) ABOUT THE CENTERLINE OF
THE COLUMN OR PILASTER.
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 2 (PREVIOUS) TO SYMMETRICALLY
ARRANGE GROUPS OF ITEMS HAVING BOTH DIFFERING AND SIMILAR MOUNTING HEIGHTS.
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE INDICATED,
MOUNT FIRST ITEM IN RELATION TO SWING USING TYP. OFFSET DIMENSION AND
PLACE REMAINING ITEMS ADJACENT TO FIRST ON SIDE OPPOSITE FRAME AS
ILLUSTRATED BY THIS DIAGRAM.
FOR PURPOSES OF THESE RULES, ITEMS SHOWN APPROX. LOCATED WITHIN 4 FEET OF
OPEN DOOR ARE CONSIDERED TO BE ADJACENT TO DOOR. THIS MAY INCLUDE THE
WALL IN WHICH THE DOOR IS LOCATED, OR AN INTERSECTING WALL AGAINST WHICH
THE DOOR OPENS.
WHEN MULTIPLE ITEMS HAVING THE SAME TYP
MTG HGT ARE INDICATED, MOUNT FIRST ITEM IN
RELATION TO FRAME USING TYP OFFSET DIM AND
PLACE REMAINING ADJ TO FIRST ON SIDE OPP
FRAME AS ILLUSTRATED BY THIS DIAGRAM. DO
NOT CROWD MULTIPLE ITEMS AGAINST WALL OR
RESTRICTION.
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJ TO STRIKE SIDE OF DOOR, AND WHEN
STRIKE-SIDE CLEARANCE IS BETWEEN 12 INCHES AND 18 INCHES, AND WHEN NO OTHER
TYPICAL CONFIGURATION DIAGRAM APPLIES: MOUNT ITEMS IN RELATION TO FRAME USING
TYP OFFSET DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT DIFFERENT
HEIGHTS.
LINE OF WALL OR OTHER
RESTRICTION ON STRIKE-SIDE OF
DOOR.
STRIKE-SIDE OF DOOR.
WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE
INDICATED, MOUNT FIRST ITEM IN RELATION TO FRAME USING TYP OFFSET
DIMENSION AND PLACE REMAINING ITEMS ADJACENT TO FIRST ON SIDE
OPPOSITE FRAME AS ILLUSTRATED BY THIS DIAGRAM.
SIMILAR RULE APPLIES WHEN ADJACENT TO WINDOW. FOR PURPOSES OF THESE
RULES, ITEMS SHOWN APPROX. LOCATED WITHIN 4 FEET OF DOOR ARE CONSIDERED
TO BE ADJACENT TO DOOR (OR WINDOW).
WHEN PROVIDED, UTILIZE TYP
MOUNTING DIAGRAMS TO
DETERMINE DIMENSIONS
MULTIPLE ITEMS AT SAME HEIGHT
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO DOOR,
AND WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:
MOUNT ITEMS IN RELATION TO FRAME USING TYP OFFSET DIMENSION.
VERTICALLY ALIGN CENTERS OF ITEMS MOUNTED AT DIFFERENT
HEIGHTS.
MULTIPLE ITEMS AT SAME HEIGHT
DOOR WHEN SWUNG AGAINST WALL
ON PLANS, ITEMS TO BE
VERTICALLY ALIGNED MAY BE
SHOWN ADJACENT.
ARRANGE ITEMS AT SAME HEIGHT
SYMMETRICALLY ABOUT CENTERLINE
MULTIPLE SIMILAR ITEMS AT SAME HEIGHT
FOR PURPOSES OF THESE RULES, ITEMS SHOWN APPROX. LOCATED
WITHIN 4 FEET OF PLANE CHANGE ARE CONSIDERED TO BE
ADJACENT TO CHANGE IN PLANE.
WHEN MULTIPLE SIMILAR ITEMS HAVING THE SAME TYP MTG HEIGHT ARE INDICATED, MOUNT
FIRST ITEM IN RELATION TO PLANE CHANGE USING TYP. OFFSET DIMENSION AND PLACE
REMAINING ITEMS ADJACENT TO FIRSTON SIDE OPPOSITE PLANE CHANGE AS ILLUSTRATED BY
THIS DIAGRAM.
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJ TO CHANGE IN PLANE OF WALL,
AND WHEN NO OTHER TYP CONFIGURATION DIAGRAM APPLIES: MOUNT ITEMS IN
RELATION TO PLANE CHANGE USING TYP. OFFSET DIM. VERTICALLY ALIGN CENTERS OF
ITEMS MOUNTED AT DIFFERENT HEIGHTS.
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR PILASTER, AND
WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES: HORIZONTALLY CENTER
GROUP OF DISSIMILAR ITEMS HAVING CONFLICTING MOUNTING HEIGHT(S) ABOUT THE
CENTERLINE OF THE COLUMN OR PILASTER.
WHEN APPLICABLE, COMBINE THIS RULE WITH RULE 2 AND/OR RULE 3 (PREVIOUS) TO
SYMMETRICALLY ARRANGE GROUPS OF ITEMS HAVING DIFFERING, SIMILAR, AND
CONFLICTING MOUNTING HEIGHTS.
GRID
ARRANGE ITEMS AT CONFLICTING HEIGHTS
SYMMETRICALLY ABOUT CENTERLINE
GRID
GRID
DIMENSION ON PLANS
EQ EQ EQ EQ
6".
EQ EQ
EQEQ
18" MIN. SWING SIDE
12" MIN. OPP. SWING SIDE
3" MIN.
8" TYP. 8" TYP.
4'-0". 4'-0". DOOR SWING
8" TYP.
8" TYP.
4'-0".
EQ EQ
EQ EQEQ EQEQEQ
• LOCATE ITEMS AS INDICATED WHEN SHOWN DIMENSIONED (BOTH HORIZ AND
VERT) BY A PLAN OR DETAIL PLAN.
• SPECIFIC VERT DIMENSIONS SHOWN BY ELEVATIONS, SECTIONAL ELEVATIONS, OR
DETAIL ELEVATIONS AND SPECIFIC HORIZ DIM SHOWN BY PLANS AND DETAIL
PLANS TAKE PRECEDENCE OVER TYPICAL MOUNTING HEIGHTS AND LOCATION
RULES.
TYPICAL RULES FOR DETERMINING MOUNTING HEIGHTS, LOCATIONS AND CONFIGURATIONS
WHEN NOT DIMENSIONED AND SHOWN LOCATED ON A COLUMN OR PILASTER, AND
WHEN NO OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES:
• HORIZONTALLY CENTER ITEM ON FACE OF COLUMN OR PILASTER.
• ALIGN VERTICALLY CENTERS OF MULTIPLE ITEMS HAVING DIFFERING TYPICAL
MOUNTING HEIGHTS.
• WHEN MULTIPLE ITEMS HAVING THE SAME TYP MOUNTING HEIGHT ARE INDICATED,
HORIZONTALLY CENTER GROUP OF ITEMS ON FACE OF COLUMN OR PILASTER
(SEE RULE 3).
WHEN NOT DIMENSIONED AND SHOWN LOCATED ADJACENT TO DOOR, AND WHEN NO
OTHER TYPICAL CONFIGURATION DIAGRAM APPLIES: MOUNT ITEMS IN RELATION TO
SWING USING TYP OFFSET DIMENSION. VERTICALLY ALIGN CENTERS OF ITEMS
MOUNTED AT DIFFERENT HEIGHTS.
TYPICAL HANDICAP ACCESSIBLE MOUNTING HEIGHTS ABOVE FINISH FLOOR AND REQUIRED CLEARANCE DIMENSIONS
DIMENSION
NAME ELEMENT
PRE-K AND KINDERGARTEN
DIMENSION
CODE
RECOMMENDED
ACTUAL
DESIGNED
FIRST THRU FIFTH GRADE
DIMENSION
ACTUAL
DESIGNED
ADULTS DIMENSION
CODE
REQUIREMENT
ACTUAL
DESIGNED
DRINKING FOUNTAIN (STANDING) 602.4 N/A N/A N/A N/A 38" - 43" 40" SPOUT HT.M1
MOUNTING HEIGHT REFERENCE
ABOVE F.F.
OR
CLEARANCE AS SPECIFIED ADDITIONAL COMMENTS
602.4 30" MAX 27" 30" MAX 30" 36" MAX 35-1/2" SPOUT HT.M2
GRAB BAR AT TOILET - 18" VERTICAL 604.5 N/A 25" N/A 32" 39" - 41" 40" TO BOTTOM OF RAILM3
GRAB BARS AT TOILET - HORIZONTAL 604.9 & 609.4 18" - 20" 22" 25" - 27" 26" 33" - 36" 34" TO TOP SURFACE OF RAILM4
THE GRAB BAR ON REAR WALL OF NON-ADULT TOILETS CAN BE SPLIT
WHEN IT CONFLICTS WITH WATER VALVE
HANDRAILS 505.4 28" MAX 24" 28" MAX 24" 34" - 38" 36" TO TOP SURFACE OF RAILM5A & M5B
M5A = ADULT DIMENSION, M5B = CHILDREN
DIMENSION OF SECOND HANDRAIL TO F.F.
LAVATORY 606.3 31" MAX 27" 31" MAX 30" 34" MAX 34"
TO HIGHEST POINT OF LAVATORY RIM OR
COUNTERM6
ONLY PRE-K AND KINDERGARTEN (IF PARALLEL APPROACH
PROVIDED) CAN HAVE SPACE BELOW LAVATORY ENCLOSED
MIRROR 606.3 N/A N/A N/A N/A 35" MAX 12"M7
MIRROR ABOVE LAVATORY 606.3 34" MAX 34" 34" MAX 34" 40" MAX 40"M8
TOILET PAPER DISPENSER 604.7 & 604.10 14" 14" 14" - 19" 15" 15" MIN 18" TO BOTTOM OF DISPENSERM9
URINAL 605 14" MAX 13" 14" MAX 13" 17" MAX 17" TO RIM, 13-1/2" MIN PROJECTIONM10
URINAL FLUSH CONTROLS 605.4 & 309 36" MAX 36" 36" MAX 36" 44" MAX 42" TO TOP OF CONTROLM11 WATER CLOSET HEIGHT 604.4 11" - 13" 15" 15" - 17" 16" 17" - 19" 18" TO TOP OF SEATM12 WATER CLOSET FLUSH CONTROLS 604.6 36" MAX ±23" 36" MAX ±29" 36" MAX ±27" LOCATED ON WHEELCHAIR SIDEM13
DRINKING FOUNTAIN (WHEELCHAIR)
ANSI A117.1
GUIDELINE
REFERENCE
CODE
RECOMMENDED
TO BOTTOM EDGE OF REFLECTING SURFACE
TO BOTTOM EDGE OF REFLECTING SURFACE
WATER CLOSET FROM WALL 604.2 12" 12" 15" - 18" 16" 16" - 18" 17" WALL TO CENTERLINE OF WATER CLOSETP1
FIRE EXTINGUISHER 308 N/A 48" MAX 48" TO RELEASE CLAMPN/A N/A N/A
CHILD CONTROLS LOCATED ABOVE SPLIT GRAB BAR
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT DATE: PLOT SCALE:
DRAWING NO. AMP-400-E-
OF
LO
C
AL
F
T D
AT
E:
LW
PB
J O
B N
O
C
EN
TR
AL
F
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
PL
AT
E:
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY
MANAGEMENT
AMP-400
PROJECT MANAGER:
WORK REQUEST NO:
BASE MAINTENANCE BUILDING
12/20/19
As indicated12/20/2019 3:26:44 PM
BI
M
FA
A M
M
AC
B as e M ai nt en an ce B ui ld in g/
M M
AC
-B
M B
R en ov at io n
Ty pe
B -A rc h.
rv t
/2
0/
:2 6:
P
M
RENOVATION OF BMB-15
(BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
MOUNTING HEIGHTS, LOCATIONS
AND CONFIGURATIONS
G-003BW
BW
2014-004363
-1
5-
G
0E
\\l w pb -fi le sr vr \F ed er al
FA
A\
FA
A
ID
IQ
\T O
B M
B R en ov at io n Ty pe B
\0
D w gs \0
Ar ch M
M
AC
-B M
B R en ov at io n Ty pe B
7.
rv t
LW
PB
0 1
6.
0 2
12/20/19
MONTE THURMAN,
AMP-400
2014-004363
MONTE THURMAN,
7"-9" M9
M3
" M
IN
MI
N.
1 1 /2"
3'-4"
TOILET
ACCESSORY
MOUNTING
LOCATION
M4M4 M1
M1
STAIRS
(a)
RAMPS
(b)
WALKING
SURFACES
(c)
M5 A
M5
AM5
A
M5 B
M5 B
SECOND HANDRAIL
M5 B
MI
N.
1'- 3"
MI
N.
5'- 0"
3'-6" 1'-0"
PROVIDE BOTH
VERTICAL AND
HORIZONTAL
GRAB BARS
P1
3'-4"
NOTE: FOR TOILETS WITH CENTERLINE LESS THAN 15", A 24" MIN. GRAB
BAR TO OPEN SIDE MAY BE USED IN LIEU OF FULL 36" MIN. LENGTH.
REFER TO MOUNTING CHART BELOW.
OPEN
SIDE
CL
2'- 0"
WALL-HUNG
M1
M1
1'-1 1/2"
M8M6 M7M6M8
REFLECTING
SURFACE
SECTION ELEVATION
" M
IN
M1M2
PLAN SECTION
FRONT APPROACHES
NOTE: X=12 IN. IF DOOR HAS BOTH A
CLOSER AND LATCH
PUSH SIDE
PULL SIDE
NOTE: Y=48 IN. MIN. IF DOOR HAS
CLOSER
LATCH SIDE APPROACHES
NOTE: X=54 IN. MIN. IF DOOR HAS
CLOSER
PUSH SIDE
PULL SIDE
IBC/ANSI/ADAAG - ACCESSIBLE ROUTE (TYPICAL FOR
ALL DOORS)
" M
IN
" M
IN
. 18"
MIN.
X
24"
MIN.
X
" M
IN
Y
" M
IN
24"
MIN.
X=42 IN. MIN. IF Y=54 IN.
NOTE: Z=48 IN. MIN. IF DOOR HAS BOTH A
CLOSER AND LATCH.
NOTE: X=36 IN. MIN. IF Y=60 IN.
HINGE SIDE APPROACHES
PUSH SIDE
PULL SIDE
X Y
Z
" M
IN
54" MIN.
HANDICAP ACCESSIBILITY ANALYSIS
1. PROJECT SCOPE
A. NEW CONSTRUCTION / REMODEL
2. PRIMARY USER GROUPS
A. ADULTS
3. ASSEMBLY SEATING ANALYSIS
A. NOT APPLICABLE
4. APPLICABLE CODES AND CRITERIA
IN ORDER TO PROVIDE THE BEST
ACCESSIBILITY, THE MOST STRINGENT
REQUIREMENTS OF THE GUIDELINES
BELOW HAVE BEEN EMPLOYED IN THIS
DESIGN:
A. INTERNATIONAL BUILDING CODE
2015 (IBC)
B. INTERNATIONAL CODE COUNCIL /
AMERICAN NATIONAL STANDARDS
INSTITUTE ICC / ANSI A117.1 - 2003
C. AMERICANS WITH DISABILITIES ACT,
2010 ADA STANDARDS FOR
ACCESSIBLE DESIGN
IBC/ANSI/ADAAG SECTION 308 - ADULT REACH RANGES
OBSTRUCTED FORWARD REACHUNOBSTRUCTED FORWARD REACH OBSTRUCTED FORWARD REACH
MI
N. 48
" M
AX
20"
MAX.
" M
AX
" M
AX
25"
MAX.
" M
AX
" M
AX
OBSTRUCTED SIDE REACHUNOBSTRUCTED SIDE REACH OBSTRUCTED SIDE REACH
MI
N. 48
" M
AX
10"
MAX.
" M
AX
" M
AX
24"
MAX.
" M
AX
" M
AX
GRAB BARS IN ROLL-IN SHOWERSROLL-IN SHOWER COMPARTMENT SIZE
& CLEARANCE
NOTE: PROVIDE LAYOUT AND ALL ACCESSORIES TO MEET CURRENT ANSI A117.1 REQUIREMENTS.
2'-
SHOWER
CURTAIN
ROD
STAINLESS
STEEL GRAB
BAR
CONTROL
AREA
STAINLESS
STEEL GRAB
BAR
ADJ-HT
SHOWER
HEAD
THRESHOLD
AS SCHED.
ROLL-IN SHOWER COMPARTMENT
(a)
CONTROL WALL
ROLL-IN SHOWER COMPARTMENT
(b)
BACK WALL
MI
N
1'- 6"
6"
MI
N.
2'-
1/
2"
5'-0"MIN.
EQ EQ.
REQ'D OPEN
FLOOR AREA
SI
DE
W
AL
L
CO
NT
RO
L W
AL
L
BACK
2'- 6"
MI
N.
2'- 6"
M
IN
5'-0"MIN.
6" MAX.
6" M
AX
4"
MA
X.
2" CO
NT
RO
L W
AL
L
BACK
SI
DE
W
AL
L
6" MAX.
6" M
AX
4"
MA
X.
2"
3'- 2 1
/2"
MI
N.
4'- 0 1
/2"
MA
X. 6'- 6 1
/2"
5'- 6"
M
AX
2'-
1/ 2"
T-SHAPED WHEELCHAIR
TURNING AREA
ACCESSIBLE ELEMENT
60" DIAMETER WHEELCHAIR
TURNING AREA
ACCESSIBLE PARKING SPACE
FOR CARS OR VANS
ACCESSIBLE ENTRANCE
ACCESSIBLE ROUTE TO
ACCESSIBLE ENTRANCES
OR FACILITIES
LEGEND
AREA OF REFUGE
HC
AR
WHEELCHAIR ACCESSIBLE
SEATING LOCATION OR
ELEMENT ACCESS
REVIEWED BY
DRAWN BY:
DESIGNED BY:
PLOT DATE: PLOT SCALE:
DRAWING NO. AMP-400-E-
OF
LO
C
AL
F
T D
AT
E:
LW
PB
J O
B N
O
C
EN
TR
AL
F
A
B
C
D
E
F
G
A
B
C
D
E
F
G
TE
M
PL
AT
E:
SENSITIVE SECURITY INFORMATION WARNING: This record contains Sensitive Security Information that is controlled under 49 CFR parts 15 and 1520, except with written permission of the Secretary of Transportation. Unauthorized release may result in civil penalty or other action. For U.S. government agencies, public disclosure is governed by 5 U.S.C. 552 and 49 CFR 15 and 1520.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
MIKE MONRONEY AERONAUTICAL CENTER - OKLAHOMA CITY, OKLAHOMA
DATE:
APPROVED BY:
ISSUED BY
OFFICE OF:
FACILITY
MANAGEMENT
AMP-400
PROJECT MANAGER:
WORK REQUEST NO:
BASE MAINTENANCE BUILDING
12/20/19
As indicated12/20/2019 3:26:48 PM
BI
M
FA
A M
M
AC
B as e M ai nt en an ce B ui ld in g/
M M
AC
-B
M B
R en ov at io n
Ty pe
B -A rc h.
rv t
/2
0/
:2 6:
P
M
RENOVATION OF BMB-15
(BASE MAINTENANCE BUILDING)
6125 SW 68TH ST, OKLAHOMA CITY, OK
ACCESSIBILITY REQUIREMENTS
G-004BW
BW
2014-004363
-1
5-
G
0E
\\l w pb -fi le sr vr \F ed er al
FA
A\
FA
A
ID
IQ
\T O
B M
B R en ov at io n Ty pe B
\0
D w gs \0
Ar ch M
M
AC
-B M
B R en ov at io n Ty pe B
7.
rv t
LW
PB
0 1
6.
0 2
12/20/19
MONTE THURMAN,
AMP-400
2014-004363
MONTE THURMAN,
AMP-400
VERTICAL BAR ELEVATION (TYP.) ACCESSIBILE HANDRAILS
ACCESSIBLE TOILET PLAN (TYP.) ACCESSIBILE URINALS ACCESSIBILE LAVATORIES & MIRRORS
ACCESSIBILE DRINKING FOUNTAINS
BUILDING CODE INFORMATION
LIFE SAFETY & FIRE PROTECTION CODE COMPLIANCE APPROACH NARRATIVE
GENERAL PROJECT INFORMATION
PROJECT NAME
PROJECT LOCATION
CONSTRUCTION PURPOSE
BUILDING OWNER
AUTHORITY HAVING JURISDICTION
PROJECT DESCRIPTION - SUMMARY
NEW ADDITION - One story (1,644 SF) consisting of vestibule, reception, and conferences. The existing fire alarm and fire suppression system will be expanded to accommodate the new construction and renovations.
EXISTING BUILDING REMODEL - Two story (51,595 SF) consisting of open office administrative areas and shop maintenance areas. The building comprises of CMU masonry and steel structure with metal stud framing.
Updates to the building constructed in 1963 include new mechanical and electrical systems, partial roof replacement, partial building envelope upgrades, storm shelter, and restroom upgrades to meet current accessibility and plumbing standards. The current fire suppression systems will be repaired or replaced to meet current codes.
ALTERNATES:
Renovation of BMB-15 (Base Maintenance Building)
6125 SW 68th St., Oklahoma City, OK 73169 Oklahoma County
Administrative Offices & Base Maintenance Shops
Federal Aviation Administration
City of Oklahoma City / Oklahoma State Fire Marshal
OPTION NO. 1: NORTH CANOPY
OPTION NO. 2: WEST CANOPY, PLANTER & PATIO
OPTION NO. 3: PARKING LOT
NOTE- REFER TO MEPS DRAWINGS FOR ADDITIONAL CODES
EGRESS WIDTH PER OCCUPANT (IBC, Section 1005):
0.2" per person at level egress components 0.3" per person at egress stairs components (10,305 SF Basement/300 = 35 Occupants)
CORRIDOR WIDTH (IBC, Section 1020.2)
1. The minimum corridor width shall be not less than 44 inches.
EXCEPTIONS:
1. Twenty-four inches-For access to and utilization of MEP systems or equipment.
2. Thirty-six inches-With a required occupant capacity of 50 or less.
Minimum Corridor width as designed = 48"
MINIMUM NUMBER OF EXITS (IBC, Table 1006.3.1) Minimum of three exits for 501 to 1,000 occupants. Number of exits as designed = 10 (1st Floor)
No required fire walls, building is equipped throughout with automatic sprinkler system.
x INTERNATIONAL EXISTING BUILDING CODE (IEBC) 2015 x INTERNATIONAL MECHANICAL CODE (IMC) 2015 x AMERICANS WITH DISABILITIES ACT (ADA) STANDARDS 1998 / 2010
ADDITIONAL CODES
x NFPA 70 NATIONAL ELECTRICAL CODE 2017 x NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 x INTERNATIONAL PLUMBING CODE (IPC) 2015 x NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2013 x NFPA 13 STANDARD INSTALLATION OF SPRINKLER SYSTEMS 2016
MIXED USE AND OCCUPANCY (IBC, Section 508)
1. Accessory use areas (Section 508.2.3): Any other accessory use area shall not be required to be separated by a fire barrier provided the aggregate accessory use occupies an area not more than 10 percent of the area of the story in which it is located.
2. Separate occupancies (Section 508.2.4): Separation of occupancies are not required between the existing building and addition.
INCIDENTAL USES (IBC, Section 509)
1. Incidental accessory occupancies (Table 509): Paint shops, not classified as Group H, located in occupancies other than Group F requires 1 hour separation with an automatic sprinkler system.
2. Occupancy Classification (Section 509.2): Incidental uses shall not be individually classified in accordance with Section 302.1. Incidental uses shall be included in the building occupancies within which they are located.
Building occupancy classification is Group B.
3. Area limitations (Section 509.3): Incidental uses shall not occupy more than 10 percent of the building area of the story in which they are located. Paint booths, battery, tire, oil, parts storage, and metal/welding shops make up less than 10% of the overall building area.
4. Protection (Section 509.4.2): Where Table 509 permits an automatic fire-extinguishing system without a fire barrier, the incidental use area shall be separated by construction capable of resisting the passage of smoke. The partitions shall extend from the floor to the underside of the fire-resistance-rated flooring/ceiling. Doors shall be self-closing.
TYPES OF CONSTRUCTION (IBC, CHAPTER 6)
FIRE RESISTANCE RATING REQ. FOR BUILDING ELEMENTS (IBC, Table 601)
For all building elements 0 0 Not Applicable
Type IIB fire-resistance rating REQUIRED DESIGNED METHOD ACHIEVING RATING
FIRE RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE
SEPARATION DISTANCE (IBC, Table 602)
FIRE RATING
FIRE SEPARATION DISTANCE = x' CONSTR. TYPE OCCUP. GROUP REQ. DESIGNED
FIRE RATING
For exterior walls w/ > 10' separation Type IIB B, F-1, S-1 0 0
FIRE AND SMOKE PROTECTION FEATURES (IBC, CHAPTER 7, 8, 9)
BUILDINGS ON THE SAME LOT (IBC, Section 705.3)
MAXIMUM AREA OF EXTERIOR WALL OPENINGS BASED ON FIRE SEPARATION
DISTANCE & DEGREE OF OPENING PROTECTION (IBC, Section 705.8.1)
Exception: Two or more buildings on the same lot shall either be regulated as separate buildings or shall be considered as portions of one building if the aggregate area of such buildings is within the limits specified in Chapter 5 for a single building. Where the buildings contain different occupancy groups or are of different types of construction, the area shall be that allowed for the most restrictive occupancy or construction.
Fire separation distance of 30' allowable openings have no limit.
INTERIOR WALL AND CEILING FINISH REQ. BY OCCUPANCY (IBC, Table 803.11)
SPRINKLERED NONSPRINKLERED
Group Exits Corridors Rooms Exits Corridors Rooms
B Class B Class C Class C A - N/A B - N/A C - N/A
FIRE PROTECTION SYSTEMS (IBC, Chapter 9) This building is equipped throughout with an automatic wet-pipe fire sprinkler system, fire alarm and mass notification system as designed.
FIRE EXTINGUISHERS FOR CLASS A FIRE HAZARDS (IBC, Table 906.3(1)) Ordinary (Moderate) Extinguishers Hazard Occupancy as Provided
Minimum Rated Single Extinguisher 2-A 4-A:60BC Maximum Floor Area/Unit of A 1,500 SF 1,500 SF Maximum Floor Area for Extinguisher 6,000 SF 5,152.5 SF Maximum Travel Distance to Extinguisher 75'-0" 74'-6"
FLOOR AREA ALLOWANCE PER OCCUPANT (IBC, Table 1004.1.2)
PUBLIC ENTRANCES (IBC, Section 1105.1) Sixty percent of all public entrances shall be accessible.
OCCUPANCY LOAD, MEANS OF EGRESS , & ACCESSIBILITY (IBC, CHAPTER 10, 11)
ACCESSIBILITY (IBC, Section 1009)
1. 1009.1 Accessible means of egress. Accessible spaces shall be provided with not less than one accessible means of egress. Where more than one means of egress is required by Section 1006.2 or 1006.3 from any accessible space, each accessible portion of the space shall be served by not less than two accessible means of egress.
2. 1009.3 Exit stairways. Stairways shall have a clear width of 48 inches minimum between handrails and shall either incorporate an area of refuge within an enlarged floor-level landing or shall be accessed from either an area of refuge. Exception: The clear width of 48 inches between handrails and the area of refuge are not required in buildings equipped throughout with an automatic sprinkler system. Building is equipped throughout with an automatic sprinkler system.
OCCUPANCY USE Total Interior Occupiable Area 53,239 SF
OCCUPANT LOAD 579 TOTAL
REQUIRED DESIGNED
WIDTH (Two Remote Exits) 579 x .2" = 115.8" 68"+68"=136"
AUTOMATIC SPRINKLER SYSTEMS (NFPA 13, Section 903.2) An automatic sprinkler system is not required for Group B use group.
x INTERNATIONAL FIRE CODE (IFC) 2015 x NFPA 101 LIFE SAFETY CODE 2015 x NFPA 285 STANDARD FIRE TEST METHOD 2014
APPLICABLE DESIGN CRITERIA (Applicable codes are checked.)
ADOPTED STATE CODES EDITION
F Class C Class C Class C B - N/A C - N/A C - N/A
S Class C Class C Class C B - N/A B - N/A C - N/A
Assembly (Conf., Break) 15 Net SF/person for 2,551 SF 2,551 SF/15 = 170.07 4,068 SF - 1,517 SF(Circulation) = 2,551 SF
Storage, Mechanical 300 Gross SF/person for 15,126 SF 15,126 SF/300 = 50.42 10,305 SF (Basement) + 4,821 SF (1st floor)
Business 100 Gross SF/person for 24,245 SF 24,245 SF/150 = 242.45
WIDTH (Total Exit Capacity) 579 x .2" = 115.8" 68"+68"+68"+68"+44"+33"+33"+33"+33"+33"=481"
OCCUPANCY COMPONENT ALLOWABLE AS DESIGNED
Common Path of Travel (Sec. 1006.2.1) 100' (Sprinklered) 60'-2"
Business, B Dead End Corridors (Table 1020.4) 50' (Sprinklered) 46'-0"
Travel to Exit (Table 1017.2) 300' (Sprinklered) 172'-2"
MAXIMUM TRAVEL DISTANCE (IBC, Chapter 10) x INTERNATIONAL ENERGY CONSERVATION CODE (IECC) 2015 x INTERNATIONAL FUEL GAS CODE (IFGC) 2015 x NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS 2016 x INTERNATIONAL BUILDING CODE (IBC) 2015 x NATIONAL ELECTRICAL CODE (NEC) 2014 x ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (ICC/ANSI A117.1) 2009 x STANDARD ON DESIGN AND CONSTRUCTION OF STORM SHELTERS (ICC 500) 2014
ROOF ASSEMBLIES (IBC, CHAPTER 15)
BUILDING OCCUPANCY, CONSTRUCTION & SEPARATION INFORMATION
USE AND OCCUPANCY CLASSIFICATION (IBC, CHAPTER 3 & NFPA)
Base Maintenance B - Business (Section 304.1) Business (Ch. 38) 53,239 SF
BUILDNG NAME IBC CLASSIFICATION NFPA 101 CLASS. GROSS AREA
GENERAL BUILDING HEIGHTS AND AREAS (IBC, CHAPTER 5)
Group B Type IIB, noncombustible Group B Type IIB, noncombustible
ALLOWABLE BUILDING HEIGHTS & AREAS BUILDING HEIGHTS & AREAS
(IBC Table 504.3, 504.4, 506.2) (As Designed)
Height (ft) 75 Height (ft) 31
Stories 4 Stories 1 above grade+basement
Area (per floor) 92,000 SF (one story above grade) Area (per floor) 42,934 SF (first floor) 69,000 SF (two+ stories above grade) 10,305 SF (basement)
VERTICAL SEPARATION OF OPENINGS (IBC, Section 705.8.5)
Exception: This section shall not apply to buildings that are three stories or less above grade.
This section shall not apply to buildings equipped throughout with an automatic sprinkler system.
FIRE WALL RESISTANCE RATINGS (IBC, Section 706.4)
B 3 Hours Not required - met allowable area.
Group Fire Resistance Rating Construction Notes
FIRE WALL RESISTANCE RATING REQUIREMENTS FOR FIRE BARRIER ASSEBLIES
OR HORIZONTAL ASSEMBLIES BETWEEN FIRE AREAS (IBC, Table 707.3.10)
B 2 Hours Not required - sprinklered building.
Group Fire Resistance Rating Construction Notes
SHAFT ENCLOSURES (IBC, Section 713) less than 4 1 Hour Existing CMU shaft is not being altered.
Connecting Stories Fire Resistance Rating Construction Notes
FIRE ALARM AND DETECTION SYSTEMS (Business B, Section 907.2.2) Manual fire alarm is required in group B occupancies when the combined occupant load is 500 or more.
Industrial 100 Gross SF/person for 11,317 SF 11,317 SF/100 = 113.17
MEANS OF EGRESS ILLUMINATION (IBC, Section 1008) The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied.
EXIT SIGNS (IBC, Section 1013)
1013.1 Exit signs. Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel.
CORRIDOR FIRE-RESISTANCE RATING (IBC, Table 1020.1)
1. Fire resistance corridor rating required is 0-hours with sprinkler system for occupancy A, B, F, S.
MINIMUM ROOF COVERING CLASSIFICATION FOR TYPES OF CONSTRUCTION (IBC, Table 1505.1) Buildings of Type IIB construction shall have Class C roof assemblies.
CLASS C ROOF ASSEMBLIES (IBC, Section 1505.4) Class C roof assemblies are those that are effective against light fire-test exposure. Class C roof assemblies and roof coverings shall be listed and identified as Class C by an approved testing agency.
MODIFIED BITUMEN ROOFING (IBC, Section 1507.11) Modified bitumen roofs shall have a design slope of not less than one-fourth unit vertical in 12 units horizontal for drainage. Modified bitumen roof coverings shall comply with CGSB 37-GP-56M, ASTM D6162, ASTM D6163, ASTM D6164, ASTM D6222, ASTM D6223, ASTM D6298 or ASTM D6509.
ROOF INSULATION (IBC, Section 1508) Above-deck thermal insulation shall be permitted provided such insulation is covered with an approved roof covering and passes the tests of NFPA 276 or UL 1256 when tested as an assembly. Polyisocyanurate board shall comply with ASTM C1289, Type I or II.
PLUMBING SYSTEMS (IBC, CHAPTER 29)
Class.