Attachment 2 - Vol 1 Drawings.pdf

PDF 15 MB Posted

Attached to
Y1DZ--502-21-222 | EHRM Infrastructure Upgrades | Pineville, LA |
Solicitation number
36C77626R0104
Issued by

About this file

This is a technical drawings file (Volume 1) supporting an infrastructure upgrade solicitation for the Department of Veterans Affairs at multiple facilities in Louisiana. The drawings provide visual documentation and specifications for the comprehensive infrastructure improvements outlined in the solicitation, which encompasses electrical system upgrades (panel replacement, power distribution for normal and emergency systems), bonding and UPS installations, Building Management System interfaces, HVAC assessment and upgrades, data center reconfiguration with rack/cabinet relocation and cable management, communication infrastructure enhancements (new data outlets, patch panels, Cat 6A cabling), physical security upgrades, fiber backbone assessment and installation campus-wide, wide area network diversification, and hazardous material abatement. The drawings apply to 20 primary buildings at the main facility (Buildings 1-9, 13-16, 45-46, 49, 136, 142, 147, and 171) as well as satellite Community-Based Outpatient Clinics (CBOCs) in Jennings, Lafayette, Lafayette Campus B, and Natchitoches. These technical drawings serve as the visual reference materials contractors will use to understand spatial layouts, existing infrastructure conditions, proposed modifications, and technical specifications necessary to develop accurate proposals and execute the scope of work.

View the file

Other files

File Type Posted
Amendment 0007.pdf PDF
ME_SUBMITTAL_PKA-AK24NL_PUZ-AH24NL_XbtyE.pdf PDF
RFI Update 10-7-26.pdf PDF
ME_SUBMITTAL_PKA-AK36NL_PUZ-AK36NL_6PSmo.pdf PDF
Amendment 0006.pdf PDF
RFI Responses.pdf PDF
Amendment 0005.pdf PDF
Amendment 0004.pdf PDF
Site Visit Agenda.pdf PDF
Amendment 0003.pdf PDF
Site Visit Sign In Sheet 8-20-26.pdf PDF
Attachment 11 - Site Visit Details.docx DOCX document
Amendment 0002.pdf PDF
Attachment 11 - Site Visit Details.docx DOCX document
Amendment 0001.pdf PDF
Attachment 9 - Division Pricing Template.xlsx XLSX spreadsheet
Attachment 4 - Vol 3 Drawings.pdf PDF
Attachment 3 - Volume 2 Drawings.pdf PDF
Attachment 10 - Wage Determination.pdf PDF
Attachment 6 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 11 - Site Visit Details.docx DOCX document
Attachment 8 - Key Personnel.docx DOCX document
Attachment 5 - Vol 4 Drawings.pdf PDF
Attachment 7 - Key Subcontractor Information.docx DOCX document
Attachment 10 - Key Subcontractor Information.docx DOCX document
Attachment 11 - Key Personnel.docx DOCX document
Attachment 9 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 1 - Specifications.pdf PDF
Attachment 8 - Vol 4 Drawings.pdf PDF
Attachment 7 - Vol 3 Drawings.pdf PDF
Attachment 3 - Vol 2 Drawings.pdf PDF
Attachment 12 - Division Pricing Template.xlsx XLSX spreadsheet
Attachment 14 - Site Visit Details.docx DOCX document
Attachment 4 - Vol 2 Drawings Part 2.pdf PDF
36C77626R0104.pdf PDF
Attachment 13 - Wage Determination.pdf PDF
Attachment 6 - Vol 2 Drawings Part 4.pdf PDF
Attachment 5 - Vol 2 Drawings Part 3.pdf PDF
Show all 38

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:3

:1

A

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\M S

-3

E

H R

M ls ta rn e s C

B U

M B

.r v t

G-001.1

COVER VOLUME 1

1 86MEL

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 24, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

ELECTRONIC HEALTH RECORD

MODERNIZATION (EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

VA PROJECT #: 502-21-222

WVS

VOLUME 1

VOLUME 1 OF 4

SHEET LIST

SHEET NUMBER SHEET NAME DWG OF DWG

GENERAL

G-001.1 COVER VOLUME 1 1 86

G-002 GENERAL INFORMATION 2 86

G-003 CAMPUS MAP 3 86

G-004 TYPICAL ICRA CONDITIONS AND DETAILS 4 86

G-005 CONTRACTOR WORK PROCEDURES 5 86

001.G-101 BUILDING 1, BASEMENT OVERALL PLAN 6 86

001.G-111 BUILDING 1, FIRST FLOOR OVERALL PLAN 7 86

001.G-121 BUILDING 1, SECOND FLOOR OVERALL PLAN 8 86

002.G-111 BUILDING 2, FIRST FLOOR, OVERALL PLAN 9 86

002.G-121 BUILDING 2, SECOND FLOOR, OVERALL PLAN 10 86

002.G-131 BUILDING 2, THIRD FLOOR, OVERALL PLAN 11 86

002.G-141 BUILDING 2, FOURTH FLOOR, OVERALL PLAN 12 86

003.G-111 BUILDING 3, FIRST FLOOR OVERALL PLAN 13 86

003.G-121 BUILDING 3, SECOND FLOOR OVERALL PLAN 14 86

003.G-131 BUILDING 3, THIRD FLOOR OVERALL PLAN 15 86

004.G-101 BUILDING 4, BASEMENT OVERALL PLAN 16 86

004.G-111 BUILDING 4, FIRST FLOOR OVERALL PLAN 17 86

005.G-101 BUILDING 5, BASEMENT FLOOR ELECTRICAL OVERALL PLAN 18 86

005.G-111 BUILDING 5, FIRST FLOOR OVERALL PLAN 19 86

005.G-121 BUILDING 5, SECOND FLOOR OVERALL PLAN 20 86

006.G-101 BUILDING 6, BASEMENT OVERALL PLAN 21 86

006.G-111 BUILDING 6, FIRST FLOOR OVERALL PLAN 22 86

006.G-121 BUILDING 6, SECOND FLOOR OVERALL PLAN 23 86

006.G-131 BUILDING 6, THIRD FLOOR OVERALL PLAN 24 86

007.G-100 BUILDING 7, BASEMENT FLOOR, OVERALL PLAN 25 86

007.G-110 BUILDING 7, FIRST FLOOR, OVERALL PLAN 26 86

007.G-120 BUILDING 7, SECOND FLOOR, OVERALL PLAN 27 86

007.G-130 BUILDING 7, THIRD FLOOR, OVERALL PLAN 28 86

007.G-140 BUILDING 7, FOURTH FLOOR, OVERALL PLAN 29 86

007.G-101 BUILDING 7, BASEMENT, OVERALL PLAN A 30 86

007.G-102 BUILDING 7, BASEMENT, OVERALL PLAN B 31 86

007.G-103 BUILDING 7, BASEMENT, OVERALL PLAN C 32 86

007.G-104 BUILDING 7, BASEMENT, OVERALL PLAN D 33 86

007.G-105 BUILDING 7, BASEMENT, OVERALL PLAN E 34 86

007.G-106 BUILDING 7, BASEMENT, OVERALL PLAN F 35 86

007.G-111 BUILDING 7, FIRST FLOOR, OVERALL PLAN A 36 86

007.G-112 BUILDING 7, FIRST FLOOR, OVERALL PLAN B 37 86

007.G-113 BUILDING 7, FIRST FLOOR, OVERALL PLAN C 38 86

007.G-114 BUILDING 7, FIRST FLOOR, OVERALL PLAN D 39 86

007.G-115 BUILDING 7, FIRST FLOOR, OVERALL PLAN E 40 86

007.G-116 BUILDING 7, FIRST FLOOR, OVERALL PLAN F 41 86

007.G-121 BUILDING 7, SECOND FLOOR, OVERALL PLAN A 42 86

007.G-122 BUILDING 7, SECOND FLOOR, OVERALL PLAN B 43 86

007.G-123 BUILDING 7, SECOND FLOOR, OVERALL PLAN C 44 86

007.G-124 BUILDING 7, SECOND FLOOR, OVERALL PLAN D 45 86

007.G-125 BUILDING 7, SECOND FLOOR, OVERALL PLAN E 46 86

007.G-126 BUILDING 7, SECOND FLOOR, OVERALL PLAN F 47 86

007.G-131 BUILDING 7, THIRD FLOOR, OVERALL PLAN A 48 86

007.G-132 BUILDING 7, THIRD FLOOR, OVERALL PLAN B 49 86

007.G-133 BUILDING 7, THIRD FLOOR, OVERALL PLAN C 50 86

007.G-134 BUILDING 7, THIRD FLOOR, OVERALL PLAN D 51 86

007.G-135 BUILDING 7, THIRD FLOOR, OVERALL PLAN E 52 86

007.G-136 BUILDING 7, THIRD FLOOR, OVERALL PLAN F 53 86

007.G-141 BUILDING 7, FOURTH FLOOR, OVERALL PLAN A 54 86

007.G-142 BUILDING 7, FOURTH FLOOR, OVERALL PLAN B 55 86

007.G-143 BUILDING 7, FOURTH FLOOR, OVERALL PLAN C 56 86

007.G-144 BUILDING 7, FOURTH FLOOR, OVERALL PLAN D 57 86

007.G-145 BUILDING 7, FOURTH FLOOR, OVERALL PLAN E 58 86

007.G-146 BUILDING 7, FOURTH FLOOR, OVERALL PLAN F 59 86

008.G-101 BUILDING 8, FIRST FLOOR OVERALL PLANS 60 86

009.G-110 BUILDING 9, FIRST FLOOR ELECTRICAL, OVERALL PLAN 61 86

009.G-111 BUILDING 9, FIRST FLOOR OVERALL PLAN A 62 86

009.G-112 BUILDING 9, FIRST FLOOR OVERALL PLAN B 63 86

009.G-113 BUILDING 9, FIRST FLOOR OVERALL PLAN C 64 86

009.G-120 BUILDING 9, SECOND FLOOR OVERALL PLAN 65 86

009.G-121 BUILDING 9, SECOND FLOOR OVERALL PLAN A 66 86

009.G-122 BUILDING 9, SECOND FLOOR OVERALL PLAN B 67 86

009.G-123 BUILDING 9, SECOND FLOOR ELECTRICAL, OVERALL PLAN C 68 86

009.G-130 BUILDING 9, THIRD FLOOR OVERALL PLAN 69 86

009.G-131 BUILDING 9, THIRD FLOOR OVERALL PLAN A 70 86

009.G-132 BUILDING 9, THIRD FLOOR OVERALL PLAN B 71 86

009.G-133 BUILDING 9, THIRD FLOOR OVERALL PLAN C 72 86

013.G-111 BUILDING 13, FIRST FLOOR OVERALL PLAN 73 86

014.G-111 BUILDING 14, FIRST FLOOR, OVERALL PLAN 74 86

015.G-111 BUILDING 15, FIRST FLOOR OVERALL PLAN 75 86

016.G-111 BUILDING 16, FIRST FLOOR, OVERALL PLAN 76 86

045.G-111 BUILDING 45, FIRST FLOOR, OVERALL PLAN 77 86

045.G-121 BUILDING 45, SECOND FLOOR, OVERALL PLAN 78 86

046.G-111 BUILDING 46, FIRST FLOOR, OVERALL PLAN 79 86

046.G-121 BUILDING 46, SECOND FLOOR, OVERALL PLAN 80 86

046.G-131 BUILDING 46, THIRD FLOOR, OVERALL PLAN 81 86

049.G-111 BUILDING 49, FIRST FLOOR, OVERALL PLAN 82 86

136.G-111 BUILDING 136, FIRST FLOOR, OVERALL PLAN 83 86

142.G-111 BUILDING 142, FIRST FLOOR, OVERALL PLAN 84 86

147.G-111 BUILDING 147, FIRST FLOOR, OVERALL PLAN 85 86

171.G-111 BUILDING 171, FIRST FLOOR, OVERALL PLANS 86 86

W

AL

TE

R DAVID VAN SCOTER

REG. NO. 9953

Docusign Envelope ID: 7FA18971-B6F6-44A9-896C-7B85FF50EEA5

3/23/2026

TELECOM ROOM PHASING NOTES

A. WORK RELATED THE REMODELING OF EXISTING ROOMS INTO NEW

TELECOMMUNICATION ROOMS SHALL BE PERFORMED SEQUENTIALLY BY

FLOOR STARTING AT THE LOWEST FLOOR LEVEL. ALL WORK, EXCLUDING

WORK IN THE TELECOMMUNICATION ROOMS, WILL BE COMPLETED ON THE

FLOOR AND APPROVED BY THE COR BEFORE PROCEEDING TO THE NEXT

FLOOR.

B. CONTRACTOR WILL BE ALLOWED TO MODIFY OR CONSTRUCT FOUR

TELECOMMUNICATION ROOMS AT A TIME. ALL FOUR ROOMS MUST BE

COMPLETED AND APPROVED BY COR PRIOR TO PROCEEDING TO WORK ON

ADDITIONAL ROOMS.

C. WORK HOURS AND SPECIAL CONSIDERATIONS WITHIN THE WORK

CONSTRAINT BY AREA MATRIX.

D. ANY DATA PORTS MOVED FROM OLD INFRASTRUCTURE TO NEW SHALL BE

OPERABLE AT THE END OF EACH WORKDAY. THE PRIORITY IS TO NOT LOSE

DATA SERVICE FOR MORE THAN ONE SHIFT.

E. COORDINATE WITH COR FOR ALL OUTAGES THAT WILL AFFECT MORE THAN 6

ROOMS AT A TIME. OUTAGE MUST BE APPROVED IN WRITING A MINIMUM OF 3

WEEKS PRIOR.

F. DATA CABLING REPLACEMENT FOR AREAS SERVED BY A NEWLY

CONSTRUCTED TELECOMMUNICATIONS ROOM SHOULD BE INSTALLED IN THE

FOLLOWING MANNER:

F.1 CONSTRUCT CLOSET, INSTALL RACKS AND EQUIPMENT.

F.2 RUN CABLING TO EACH ROOM SERVED BY THE CLOSET DOWN THE

CORRIDORS AND COIL THE CABLE IN EACH DESTINATION ROOM.

F.3 TERMINATE ALL CABLES AT THE PATCH PANELS WITHIN THE NEW

CLOSET.

F.4 PULL OUT OLD CABLES AT EACH ROOM AND TERMINATE AT NEW

PORTS SPECIFIED. A MAXIMUM OF 6 ROOMS CAN BE TAKEN OUT

OF SERVICE AT A TIME.

F.5 BLANK ANY FACEPLATES NO LONGER USED UP, AND INSTALL

FACEPLATE COVERS.

F.6 COORDINATE WITH THE COR TO BE PRESENT DURING TEST AND

CERTIFY ALL CABLES PER SPECIFICATION PRIOR TO MOVING TO

NEXT ROOMS.

F.7 PLUG ALL EXISTING EQUIPMENT INTO NEW PORTS.

G. DATA CABLING REPLACEMENT FOR AREAS SERVED BY A MOVED

TELECOMMUNICATIONS ROOM SHOULD BE INSTALLED IN THE FOLLOWING

MANNER:

G.1 DATA CABLING REPLACEMENT FOR AREAS SERVED BY A MOVED

TELECOMMUNICATIONS ROOM SHOULD BE INSTALLED IN THE

FOLLOWING MANNER:

G.2 BUILD ONE NEW RACK AT A TIME IF SPACE IS CONSTRAINED. RUN

CABLING TO EACH ROOM SERVED BY THE CLOSET DOWN THE

CORRIDORS AND COIL THE CABLE OUTSIDE EACH ROOM.

G.3 TERMINATE ALL CABLES AT THE PATCH PANELS WITHIN THE NEW

RACK.

G.4 PULL OUT OLD CABLES AT EACH ROOM AND TERMINATE AT NEW

PORTS SPECIFIED. A MAXIMUM OF 6 ROOMS CAN BE TAKEN OUT OF

SERVICE AT A TIME.

G.5 BLANK ANY FACEPLATES NO LONGER USED UP, AND INSTALL

FACEPLATE COVERS.

G.6 COORDINATE WITH THE COR TO BE PRESENT DURING TEST AND

CERTIFY ALL CABLES PER SPECIFICATION PRIOR TO MOVING NEXT

ROOMS. PLUG ALL EXISTING EQUIPMENT INTO NEW PORTS.

G.7 REPEAT FOR EACH RACK UNTIL ALL RACKS IN CLOSET ARE

COMPLETE.

H. REMOVE ALL EXISTING CABLING THAT HAS BEEN DISCONNECTED AS PART OF

THIS PROJECT. REMOVE CABLING BY FLOOR AFTER COMPLETION OF NEW

DATA CABLING ON THAT FLOOR.

I. CONTRACTOR TO PROVIDE A DRAFT PHASING PLAN DENOTING THE ORDER IN

WHICH THE TELECOM IMPROVEMENTS WILL BE COMPLETED WITHIN 30 DAYS

OF PROJECT AWARD. THE PHASING PLAN SHALL ADDRESS THE FOLLOWING

REQUIREMENTS:

I.1 SIMULTANEOUS OPERATION OF OLD AND NEW TELECOMMUNICATION

ROOMS (TRs): DURING THE CUTOVER PERIOD, EXISTING CONNECTIONS TO OLD TRs MUST REMAIN ACTIVE UNTIL FULL CUTOVER TO THE NEW

TR IS COMPLETE. THE PHASING PLAN SHALL EXPLICITLY DESCRIBE HOW

OLD AND NEW TRs WILL BE KEPT OPERATIONAL SIMULTANEOUSLY

THROUGHOUT THE TRANSITION.

I.2 A-SIDE / B-SIDE DISTRIBUTION CUTOVER SEQUENCE: THE

RECOMMENDED APPROACH FOR TRANSITIONING FROM OLD TRs TO NEW TRs IS AS FOLLOWS:

a. BRING UP THE NEW B-SIDE DISTRIBUTION TO ALL NEW TRs WHILE LEAVING THE OLD TRs ACTIVE ON THE EXISTING

DISTRIBUTION.

b. ONCE ALL NEW TRs ARE FULLY OPERATIONAL ON THE A-SIDE

DISTRIBUTION, PROCEED TO MOVE THE A-SIDE

DISTRIBUTION TO THE NEW TRs.

c. AT NO POINT SHALL BOTH THE B-SIDE AND B-SIDE

DISTRIBUTIONS BE IN TRANSITION SIMULTANEOUSLY. THIS

ENSURES CONTINUOUS NETWORK CONNECTIVITY

THROUGHOUT THE CUTOVER PROCESS.

I.3 NATIONAL OIT SWING SWITCH LIMITATION: NATIONAL OIT LIMITS THE

NUMBER OF SWING SWITCHES TO 10 PER SITE AT ANY GIVEN TIME. SINCE

NO NEW SWITCHES ARE PROVIDED UNDER THIS CONTRACT AND EXISTING

EQUIPMENT IS BEING RELOCATED, THE PHASING PLAN SHALL ACCOUNT

FOR THIS CONSTRAINT. THE NUMBER OF TRs BEING CUT OVER

SIMULTANEOUSLY SHALL NOT EXCEED THE AVAILABLE SWING SWITCH

ALLOTMENT.

I.4 4 NATIONAL OIT ADVANCE NOTIFICATION: NATIONAL OIT REQUIRES A

MINIMUM OF 4 WEEKS ADVANCE NOTICE PRIOR TO ANY PROPOSED TR

CUTOVER ACTIVITY SO THAT SWITCHES CAN BE RECONFIGURED. THE

CONTRACTOR SHALL INCORPORATE THIS LEAD TIME INTO THE PHASING

PLAN AND SUBMIT CUTOVER NOTIFICATIONS TO NATIONAL OIT IN

ACCORDANCE WITH THIS REQUIREMENT. THE COR SHALL BE COPIED ON

ALL SUCH NOTIFICATIONS.

J. CONTRACTOR SHOULD KEEP A ROLLING 3 WEEK LOOK AHEAD DENOTING

SCHEDULE FOR CABLING WORK IN EACH AREA.

K. CONTRACTOR TO SCHEDULE WALK THROUGH OF EACH DEPARTMENT AT

LEAST 90 DAYS PRIOR TO STARTING WORK TO DISCUSS SEQUENCING AND

DISCUSS REQUIREMENTS OF EACH DEPARTMENT.

L. ALL ICRA REQUIREMENTS TO BE VERIFIED WITH VA COR AND INFECTION

CONTROL PERSONNEL PRIOR TO BEGINNING WORK. ADJUSTMENTS TO THE

ICRA REQUIREMENTS LISTED IN THESE DOCUMENTS SHALL BE MADE

ACCORDING TO INFECTION CONTROL PERSONNEL DIRECTION.

M. CONTRACTOR WILL BE RESPONSIBLE TO SETUP ALL PROJECT MEETINGS

USING THE MICROSOFT TEAMS OR AN EQUIVALENT APPLICATION.

DISCIPLINE CALL OUT

(GENERAL, ARCH, MP - MECHANCIAL AND PLUMBING,

ET - ELECTRICAL AND TECHNOLOGY, ETC.)

SHEET NO. EXAMPLE ## A 001

SHEET NUMBER

BUILDING NUMBER REFERENCE CALL OUT

(1, 5, 6, 19, 22)

PURPOSE: THE PUBLIC BUILDINGS AMENDMENT ACT OF 1988, PUBLIC LAW (PUB. L.) 100-678 REQUIRES FEDERAL AGENCIES TO FOLLOW NATIONAL RECOGNIZED "MODEL" BUILDING CODES. THE FEDERAL PARTICIPATION IN THE DEVELOPMENT AND USE OF VOLUNTARY STANDARDS, OFFICE OF MANAGEMENT AND BUDGET (OMB) CIRCULAR A-119, REQUIRES ALL EXECUTIVE AGENCIES TO RELY ON VOLUNTARY STANDARDS, BOTH DOMESTIC AND INTERNATIONAL, WHENEVER FEASIBLE, AND TO PARTICIPATE IN VOLUNTARY STANDARD BODIES.

GENERAL: VA HAS ADOPTED THE LATEST EDITION OF THE FOLLOWING CODES AND STANDARDS AS A MINIMUM FOR ALL PROJECTS PERFORMED IN THE MODERNIZATION, ALTERATION, ADDITION, OR IMPROVEMENT OF ITS REAL PROPERTY AND THE CONSTRUCTION OF NEW STRUCTURES. VA DESIGN MANUALS AND MASTER SPECIFICATIONS SPECIFY OTHER

CODES AND STANDARDS THAT VA FOLLOWS ON ITS PROJECTS:

• VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, VA NATIONAL CAD STANDARD APPLICATION GUIDE, AND OTHER GUIDANCE ON THE TECHNICAL INFORMATION LIBRARY (TIL) (HTTP://WWW.CFM.VA.GOV/TIL/).

• INTERNATIONAL BUILDING CODE (IBC) 2021 (ONLY WHEN SPECIFICALLY REFERENCED IN VA DESIGN DOCUMENTS, SEE

NOTES BELOW)

• NFPA 101 LIFE SAFETY CODE 2021 (SEE NOTES BELOW)

• NFPA NATIONAL FIRE CODES WITH THE EXCEPTION OF NFPA 5000 AND NFPA 900

• OCCUPATIONAL, SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS.

• VA SEISMIC DESIGN REQUIREMENTS, H-18-8

• NATIONAL ELECTRICAL CODE (NEC)

• ANSI/TIA

• INTERNATIONAL PLUMBING CODE (IPC) 2021

• SAFETY CODE FOR ELEVATORS AND ESCALATORS, AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) A 17.1.

• ASME BOILER AND PRESSURE VESSEL CODE

• ASME CODE FOR PRESSURE PIPING

• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) INCLUDING VA SUPPLEMENT, BARRIER FREE

DESIGN STANDARD (PG-18-13)

• BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE, AMERICAN CONCRETE INSTITUTE AND COMMENTARY

(ACI 318)

• MANUAL OF STEEL CONSTRUCTION, LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATIONS FOR STRUCTURAL

STEEL BUILDINGS, AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)

• ENERGY POLICY ACT OF 2005 (EPACT)

• DOE INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW LOW-RISE RESIDENTIAL BUILDINGS, 10 CFR PARTS 433, 434 AND 435.

• FEDERAL LEADERSHIP IN HIGH PERFORMANCE AND SUSTAINABLE BUILDINGS: MEMORANDUM OF UNDERSTANDING

(MOU)

• THE PROVISIONS FOR CONSTRUCTION AND SAFETY SIGNS. STATED IN THE GENERAL REQUIREMENTS SECTION 01 00 00

OF THE SPECIFICATIONS.

• VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY – ASHRAE STANDARD 62.1- 2019.

• SAFETY STANDARD FOR REFRIGERATION SYSTEMS – ASHRAE STANDARD 15 – 2019.

LOCAL CODES: AS AN AGENCY OF THE FEDERAL GOVERNMENT, VA IS NOT SUBJECT TO LOCAL IMPOSITION OF CODE ENFORCEMENT PROCEDURES (DRAWING REVIEWS, BUILDING PERMITS, INSPECTIONS, FEES, ETC.). VA MUST FUNCTION AS THE AUTHORITY HAVING JURISDICTION (AHJ) AND THUS HAS THE RESPONSIBILITY TO GUARD PUBLIC HEALTH AND SAFETY THROUGH ENFORCING ITS ADOPTED CODES. HOWEVER, LOCAL AUTHORITIES SHOULD BE NOTIFIED ABOUT PLANNED PROJECTS AND GIVEN OPPORTUNITY TO REVIEW DRAWINGS PROVIDED THAT VA DOES NOT PAY FOR REVIEW

OR INSPECTION FEES.

NOTES:

1. NFPA 101 PRIMARILY ADDRESSES LIFE SAFETY AND FIRE PROTECTION FEATURES WHILE THE IBC ADDRESSES A WIDE RANGE OF CONSIDERATIONS, INCLUDING, BUT NOT LIMITED TO, STRUCTURAL STRENGTH, SEISMIC STABILITY, SANITATION, ADEQUATE LIGHT AND VENTILATION, AND ENERGY CONSERVATION. VA BUILDINGS MUST MEET THE REQUIREMENTS OF NFPA 101 AND DOCUMENTS REFERENCED BY NFPA 101 IN ORDER TO COMPLY WITH THE ACCREDITATION REQUIREMENTS OF THE JOINT COMMISSION. THEREFORE, DESIGNS SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF NFPA 101 AND DOCUMENTS REFERENCED THEREIN. DESIGN FEATURES NOT ADDRESSED BY NFPA 101 OR DOCUMENTS REFERENCED THEREIN SHALL COMPLY WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE IBC OR AS OTHERWISE ADDRESSED ABOVE IN THIS PROGRAM GUIDE. FOR DESIGN FEATURES THAT ARE ADDRESSED BY BOTH THE IBC AS WELL AS NFPA 101 OR A DOCUMENT REFERENCED BY NFPA 101, THE REQUIREMENTS OF NFPA 101 OR THE DOCUMENT REFERENCED BY NFPA 101 SHALL BE USED EXCLUSIVELY (THIS

APPLIES EVEN IF THE IBC REQUIREMENTS ARE DIFFERENT).

2. CONFLICTS BETWEEN NATIONALLY RECOGNIZED CODES AND STANDARDS AND VA REQUIREMENTS – SHOULD A CONFLICT EXIST BETWEEN VA REQUIREMENTS AND VA ADOPTED NATIONALLY RECOGNIZED CODES AND STANDARDS, THE CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF VA. THE RESOLUTION OF THE CONFLICT SHALL BE MADE BY

THE AUTHORITY HAVING JURISDICTION FOR VA TO ENSURE A CONSISTENCY SYSTEM WIDE.

WALL SECTION

SYMBOL

INTERIOR ELEVATION

SYMBOL

COLUMN GRID

ELEVATION SYMBOL

REVISION NOTE

ENLARGED DETAIL CALLOUT

ROOM DESIGNATION

SYMBOL

BREAK LINE

ROOF SLOPE

DIRECTION SYMBOL

TYPICAL GRAPHIC SCALE

DETAIL #

PAGE #

DETAIL #

PAGE #

VIEW NORTH ARROW

A8.1

EXTERIOR ELEVATION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

A8.1

BUILDING SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

A8.1

DETAIL SECTION

SYMBOL

DETAIL #

PAGE #

A8.1

WALL GRID

(REPRESENTS

FACE OF EXISTING

WALL)

XX.X

XX.X

ELEVATION

0'-0"

ROOM

NAME

101A

NORTHNORTH

0 4 8 16

BLDG BUILDING

CENTERLINE

CLR CLEAR

COL COLUMN

CONC CONCRETE

CONST CONSTRUCTION

COR CONTRACTING

OFFICER

REPRESENTATIVE

DEMO DEMOLITION

DET/DTL DETAIL

DIM DIMENSION

DWG(S) DRAWING(S)

FEC FIRE EXTINGUISHER

CABINET

FIN FINISH

FLR FLOOR

FT FOOT/FEET

GC GENERAL CONTRACTOR

GA GAUGE

GEN GENERAL

GYP GYPSUM

IN INCH

INSUL INSULATION

INT INTERIOR

MAX MAXIMUM

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MTL METAL

NIC NOT IN CONTRACT

NTS NOT TO SCALE

NOM NOMINAL

RM ROOM

SF SQUARE FEET

SS STAINLESS STEEL

SIM SIMILAR

SPEC SPECIFICATIONS

SQ SQUARE

TYP TYPICAL

UNO UNLESS NOTED

OTHERWISE

VA VETERAN AFFAIRS

VIF VERIFY IN FIELD

W/ WITH

W/O WITHOUT

CL

262 FEET (80 METERS)262 FEET (80 METERS)

F

E E

T

M

E T

E R

S

F

E E

T

M

E T

E R

S

TELECOMMUNICATIONS

ROOM

MAXIMUM COVERAGE AREA

PER TELECOMMUNICATION

ROOM

VA ALEXANDRIA HEALTH CARE SYSTEM

2495 SHERVEPORT HWY, 71N

PINEVILLE, LA 71360

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:2

:1

A

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\M S

-3

E

H R

M ls ta rn e s C

B U

M B

.r v t

G-002

GENERAL INFORMATION

2 86MEL

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 24, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

WVS

CODE STANDARDS AND EXECUTIVE ORDERS

GENERAL SYMBOL LEGEND

TELECOMMUNICATION

ROOM COVERAGE LEGEND

PROJECT LOCATION MAP PROJECT SITE MAP

PROJECT IMAGE

W

AL

T115

T117

T120

8A

JACIE DRIVE

WAREHOUSE DRIVE

VETERANS LOOP

VETERANS LOOP

WELLNESS LANE

NORTH ENTRANCE

OAK VIEW DRIVEW

VETERANS LOOP

OAK VIEW DRIVEW

VETERANS LOOP

CHAPEL DRIVE

H

SCENIC VIEW ROAD

SCENIC VIEW ROAD

SCENIC VIEW ROAD

E85 LANE

VETERANS LOOP

CHILLER DRIVE

BUILDING NOT IN SCOPE

BUILDING IN SCOPE

LEGEND

GENERAL PARKING AREA

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:2

:1

A

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\M S

-3

E

H R

M ls ta rn e s C

B U

M B

.r v t

G-003

CAMPUS MAP

3 86MEL

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 24, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

WVS

Scale: No Scale

CAMPUS MAP

N O

R T H

W

AL

TELECOM OR OTHER

FUNCTIONAL ROOM

CORRIDOR

NON-RATED TEMPORARY

BARRIER

TEMPORARY DOOR

NEW DOOR

NEW ROUGH OPENING

M

IN

C

L R

STICKY MATS

TELECOM OR OTHER

FUNCTIONAL ROOM

CORRIDOR

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

EXISTING DOOR

STICKY MATS

NEW DOOR AT CORRIDOR EXISTING DOOR TO REMAIN

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

CORRIDOR

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

NEW DOOR

NEW ROUGH OPENING

STICKY MATS

NEW WALLS

M

IN

C

L R

TELECOM OR OTHER

FUNCTIONAL ROOM

CORRIDOR

NON-RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

REMOVE EXISTING DOOR

AND FRAME

INFILL ROUGH OPENING

AS NEEDED

M

IN

C

L R

STICKY MATS

EXISTING DOOR AND FRAME TO BE

REMOVED

NEW DOOR AND ROOM AT

CORRIDOR

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

CORRIDOR

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

NEW DOOR

NEW ROUGH OPENING

STICKY MATS

DEMO EXISTING WALLS

M

IN

C

L R

NEW DOOR AND ROOM AT

CORRIDOR

NEW FLOOR FINISH

DEMO FLOOR FINISHES

NEW TELECOM ROOM IN OPEN

SPACE

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

STICKY MATS

REMOVE EXISTING

EQUIPMENT

TELECOM OR OTHER

FUNCTIONAL ROOM

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

EXISTING DOOR

STICKY MATS

EXISTING DOOR TO REMAIN

TELECOM OR OTHER

FUNCTIONAL ROOM

DEMO EXISTING WALLS

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

CORRIDOR

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

NEW DOOR

NEW ROUGH OPENING

STICKY MATS

M

IN

C

L R

NEW DOOR AND ROOM AT

CORRIDOR

EXISTING ROOM

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

STICKY MATS

NEW DOOR AND WALL AT EXISTING

ROOM

EXISTING

NEW DOOR

NEW WALL

EXISTING ROOM

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

REMOVE EXISTING DOOR

AND FRAME

INFILL ROUGH OPENING

AS NEEDED

STICKY MATS

NEW TELECOM AT STORAGE ROOM

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

EXISTING DOOR

STICKY MATS

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

EXISTING DOOR

STICKY MATS

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

EXISTING ROOM

CORRIDOR

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

EXISTING DOOR

STICKY MATS

TEMPORARY BARRIER

45-MIN RATED

TEMPORARY DOOR

STICKY MATS

REMOVE EXISTING

EQUIPMENT

NEW TELECOM AT OPEN SPACE

NEW TELECOM OR

OTHER FUNCTIONAL

ROOM

VACANT LARGE

SPACE

STICKY MATS

1-HR RATED TEMPORARY

BARRIER

45-MIN RATED

TEMPORARY DOOR

STICKY MATS

NEW DOOR

NEW WALL

NEW TELECOM AT NURSE STATION

PLASTIC SHEET ICRA BARRIER

ZIPPER DOOR

NEW DATA RECEPTACLE

STICKY MAT

INDIVIDUAL RECEPTACLE

CORRIDOR

PLASTIC SHEET ICRA

BARRIER

ZIPPER DOOR

ABOVE CEILING WORK IN CORRIDOR

CABLE TRAY WORK

ABOVE

STICKY MATS

PLASTIC SHEET

ICRA BARRIER

ZIPPER DOOR

EXISTING WALL

NURSE STATION OR

OPEN WORK AREA

NEW DATA

RECEPTACLE

EXISTING WALL

EXISTING CASEWORK

20'-0" MAX

C L E

A R

M

IN

OPEN OFFICE AREA

DUST CONTROL PLAN NOTES

1. PROVIDE STICKY MATS AT THE PLASTIC BARRIERS AND CHANGE DAILY

OR MORE OFTEN AS NEEDED TO PREVENT THE SPREAD OF DUST AND

DEBRIS INTO ADJACENT CLEAN SPACE.

INTERNAL DEMOLITION AND CONSTRUCTION ACTIVITIES DUST AND

DEBRIS CONTROL

2. USE CORRIDORS AS PRIMARY CONSTRUCTION ACCESS AS POSSIBLE.

3. TRAFFIC CONTROL: DESIGNATED ENTRY AND EXIT PROCEDURES

SHALL BE DEFINED. EGRESS PATHS SHALL BE FREE OF DEBRIS;

DESIGNATED ELEVATORS SHALL BE USED DURING SCHEDULED

TIMES; AND ONLY AUTHORIZED PERSONNEL SHALL BE ALLOWED

TO ENTER THE CONSTRUCTION ZONE. SIGNAGE SHALL DIRECT

PEDESTRIAN TRAFFIC AWAY FROM THE CONSTRUCTION AREA AND

MATERIALS.

4. CONTRACTOR SHALL USE TWO CARTS TO TRANSFER CONSTRUCTION

MATERIAL IN AND OUT OF THE PROJECT. A CLEAN CART SHALL BE

USED TO BRING IN ALL MATERIAL. A NOT-SO-CLEAN CART SHALL BE

USED TO REMOVE ALL MATERIAL FROM THE CONSTRUCTION AREA.

5. DEMOLITION DEBRIS: DEBRIS SHALL BE REMOVED IN CARTS WITH

TIGHTLY FITTED COVERS, USING DESIGNATED TRAFFIC

ROUTES.EFFORTS SHALL BE MADE TO MINIMIZE USE OF ELEVATORS

WITH AN EMPHASIS ON TRANSPORT DURING THE LOWEST PERIOD OF

ACTIVITY. DEBRIS SHALL BE REMOVED DAILY AND AT TIMES SPECIFIED

BY THE VAMC. IF CHUTES ARE USED TO DIRECT DEBRIS OUTSIDE,

HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTERED NEGATIVE AIR

MACHINES SHALL BE USED, AND THE CHUTE OPENING SHALL BE

SEALED WHEN NOT IN USE. FILTERS SHALL BE BAGGED AND SEALED

BEFORE BEING TRANSPORTED OUT OF THE CONSTRUCTION AREA.

THE CONTRACTOR SHALL NOT HAUL DEBRIS THROUGH PATIENT-CARE

AREAS WITHOUT PRIOR APPROVAL OF THE COR.

6. EXTERIOR WINDOWS: WINDOWS SHALL BE SEALED TO MINIMIZE

INFILTRATION FROM ANY ADJACENT EXCAVATION DEBRIS.

7. ALL EQUIPMENT REMAIN IN THE ORs AND ASSOCIATED ROOMS SHALL

BE COVERED AND PROTECTED PRIOR STARTING EACH

CONSTRUCTION PHASE.

VENTILATION AND ENVIRONMENTAL CONTROLS

8. AIR SYSTEM FLOW: THE COR VERIFY AND ACKNOWLEDGE

CONTRACTOR WHETHER THE CONSTRUCTION AREA USES

FRESH/OUTSIDE OR RE-CIRCULATED AIR; FILTERS SHALL BE ADDED

OR RETURN VENTS COVERED AS NEEDED WITH FILTER MATERIAL OR

PLASTIC. AIR MUST FLOW FROM CLEAN TO DIRTY AREAS.

9. NEGATIVE AIR PRESSURE: THE AIR WITHIN THE CONSTRUCTION AREA

SHALL BE NEGATIVE WITH RESPECT TO SURROUNDING AREAS AND

WITH NO DISRUPTION OF AIR SYSTEMS OF ADJACENT AREAS. USE OF

THE NEGATIVE AIR PRESSURE SYSTEM WITHIN THE ENCLOSURE TO

REMOVE DUST SHALL PASS AIR THROUGH AN INDUSTRIAL GRADE,

PORTABLE HEPA FILTER CAPABLE OF FILTRATION RATES OF 300-800

CUBIC FEET PER MINUTE (FT3/MIN), OR EXHAUST AIR DIRECTLY TO THE

OUTSIDE IF APPROVED BY VAMC. IF EXHAUST SHALL BE TIED INTO A

RE-CIRCULATED AIR SYSTEM, A PRE-FILTER AND HEPA FILTER SHALL

BE USED BEFORE EXHAUST TO PREVENT CONTAMINATION OF THE

DUCTS. CONTINUOUS MONITORING FOR NEGATIVE AIR IS REQUIRED.

10. ADJACENT AREAS: THE STATUS OF SEALED PENETRATIONS AND

INTACT CEILING SHALL BE VERIFIED DAILY.

11. AIR EXCHANGE RATES AND PRESSURE RELATIONSHIPS: VAMC AND

CONTRACTOR SHALL VERIFY AND MAINTAIN PROPER RATES IN

CRITICAL AREAS NEAR CONSTRUCTION ACTIVITY AND ENSURE AIR IS

NOT BEING RE-CIRCULATED WITHOUT FILTRATION FROM THE

CONSTRUCTION AREA ELSEWHERE. PROVIDE AIR PRESSURE TESTING

THROUGHOUT THE PROJECT IN THE FREQUENCY AS IDENTIFIED BY

THE COR.

CONTAMINATION OF PATIENT ROOMS, SUPPLIES, EQUIPMENT AND

RELATED AREAS

12. WORKSITE CLOTHING: CONTRACTOR PERSONNEL CLOTHING SHALL BE

FREE OF LOOSE SOIL AND DEBRIS BEFORE LEAVING THE

CONSTRUCTION AREA. IF PROTECTIVE APPAREL IS NOT WORN (E.G.,

COVERALLS, FOOTGEAR AND HEADGEAR) A HEPA-FILTERED VACUUM

SHALL BE USED TO REMOVE DUST FROM CLOTHING BEFORE LEAVING

THE BARRICADE. IF PROTECTIVE APPAREL IS UTILIZED, THE

CONTRACTOR SHALL CONSTRUCT A SPACE OR ANTEROOM FOR

CHANGING CLOTHING AND STORING EQUIPMENT (DESIGNATED AREA.

ALL EQUIPMENT, TOOLS, TOOL CARTS, AND MATERIALS TRANSPORTED

THROUGH OCCUPIED AREAS SHALL BE MADE FREE FROM DUST AND

MOISTURE BY VACUUMING AND WET WIPING BEFORE THEIR REMOVAL

FROM THE CONSTRUCTION ZONE OR WORK AREA.

13. POST CONSTRUCTION: DO NOT REMOVE BARRIERS AND KEEP ALL

HVAC ISOLATION UNTIL CONSTRUCTION SITE HAS BEEN CLEANED.

ICRA NOTES

PLASTIC WINDOW

SWIVEL CASTERS

WITH TWO

LOCKING BRAKES

MOBILE CART

A D

J U

S T

A B

L E

H E

IG

H

T

HEPA NEGATIVE

AIR UNIT

EXISTING WALL

EXISTING CEILING

FLEX DUCT

EXISTING CEILING

SYSTEM

BASE - TO MATCH

EXISTING AREA

EXISTING FLOOR

UNDERSIDE OF EXISTING

DECK

C E

IL

IN

G H

E

IG

H T

V A

R

IE

S F

IE

L D

V E

R

IF

Y

W A

L L

H E

IG

H

T V

A R

IE

S

F

IE

L D

V E

R

IF

Y

4 7/8"

EXISTING CEILING

SYSTEM

BASE - TO MATCH

EXISTING AREA

EXISTING FLOOR

UNDERSIDE OF

EXISTING DECK

C E

IL

IN

G H

E

IG

H T

V A

R

IE

S F

IE

L D

V E

R

IF

Y

/2

4 7/8"

EXISTING CEILING

SYSTEM

BASE - TO MATCH

EXISTING AREA

EXISTING FLOOR

UNDERSIDE OF EXISTING

DECK

C E

IL

IN

G H

E

IG

H T

V A

R

IE

S F

IE

L D

V E

R

IF

Y

W A

L L

H E

IG

H

T V

A R

IE

S

F

IE

L D

V E

R

IF

Y

6 1/8"

FIRE RESISTANT

SEALANT, BOTH SIDES

FIRE RESISTANT

SEALANT, BOTH SIDES

FIRE RESISTANT

SEALANT, BOTH SIDES

1-HR RATED AND SMOKE RATED

U.L. DESIGN NO. U404

SMOKE RATED 2-HR RATED AND SMOKE RATED

U.L. DESIGN NO. U404

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:2

:1

A

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\M S

-3

E

H R

M ls ta rn e s C

B U

M B

.r v t

G-004

TYPICAL ICRA CONDITIONS AND

DETAILS

4 86MEL

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 24, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

WVS

Scale: 1/4" = 1'-0"

TYPICAL ICRA CONDITIONS

A. REMOVE ALL TRASH DAILY FROM THE WORK AREA.

B. THESE DRAWINGS ARE BASED ON FIELD SURVEY

AND EXISTING PLANS. VERIFY ALL FIELD CONDITIONS.

C. COORDINATE WITH VA COR FOR OFF-HOURS

SCHEDULE AND TEMPORARY REROUTING ACCESS

FOR HOSPITAL STAFF AND VISITORS, PRIOR TO

ERECTING TEMPORARY BARRIERS.

D. CONSULT WITH VA SAFETY DEPARTMENT TO

MAINTAIN MINIMUM CLEARANCE IN CORRIDORS AND

HALLWAYS.

E. EXISTING WINDOWS THAT NEED TO BE TEMPORARILY

REMOVED TO ACCOMMODATE DISCHARGED AIR

EXHAUST DUCT, SHALL BE REINSTALLED AFTER

CONSTRUCTION.

F. CONTRACTOR TO VERIFY AND COORDINATE FINAL

AND APPROVED ICRA MEASURES WITH THE VA ICRA

PERSONNEL, PRIOR TO THE COMMENCEMENT OF

CONSTRUCTION ACTIVITY.

G. CONTRACTOR SHALL VISIT ALL AREAS OF WORK,

INCLUDING WALKING THE SITE, MEASURING EXISTING

DIMENSIONS AND OBSERVING EXISTING CONDITIONS

BEFORE BEGINNING WORK ORDERING MATERIALS,

OR STARTING ANY CONSTRUCTION. CONTRACTOR

TO FIELD VERIFY ALL DIMENSIONS OF EXISTING SITE

CONDITION PRIOR TO START OF WORK AND

ORDERING OF MATERIALS.

H. CONTRACTOR SHALL RECYCLE REMOVED

MATERIALS WHENEVER POSSIBLE. SEE DIVISION 1

SPECIFICATIONS.

I. CONTRACTOR TO PROTECT AREA ADJACENT TO THE

DEMOLITION AND NEW CONSTRUCTION WORK TO

PREVENT DAMAGES. IF DAMAGED, REPAIR, PATCH,

REPLACE, OR SAND SMOOTH AND TO MATCH

EXISTING ADJACENT MATERIALS. REPORT ANY AND

ALL DAMAGES TO COR.

J. CONTRACTOR SHALL REPORT TO COR IMMEDIATELY

WHEN DISCREPANCIES TO THE DRAWINGS ARE

FOUND IN THE FIELD.

K. CONTRACTOR TO INSTALL TEMPORARY DIGITAL

MANOMETER TO MONITOR AND ENSURE PRESSURE

LEVEL TO MEET VA GUIDELINE WITHIN

CONSTRUCTION AREA. WITH VA COR PRIOR TO

INSTALLATION.

L. PROTECT AND COVER HVAC DIFFUSERS WITHIN

ROOMS DURING CONSTRUCTION.

M. CONTRACTOR SHALL COVER ALL FURNITURE WITHIN

ROOM WITH PLASTIC, PRIOR TO COMMENCING WORK

IN A SPACE AND REMOVE PRIOR TO POST-

CONSTRUCTION TERMINAL CLEANING.

N. TEMPORARY BARRIERS SHALL BE INSPECTED BY VA

LIFE SAFETY AND ICRA STAFF PRIOR TO START OF

CONSTRUCTION IN SPACE. MAINTAIN NEGATIVE

PRESSURE VENTILATION IN CONSTRUCTION SPACE.

O. DOORS TO CORRIDORS FROM OCCUPIED ROOMS

SHALL NOT BE BLOCKED DURING SHIFTS.

P. IF ABOVE CEILING WORK WILL BLOCK ENTIRE

CORRIDOR (SUCH AS IN A 5'-0" WIDE NON-ACUTE

CORRIDOR), WORK MUST OCCUR OUTSIDE NORMAL

OPERATING HOURS FOR THAT AREA.

Q. USE OF MODULAR ICRA BARRIERS IN LIEU OF

CONSTRUCTED BARRIERS MUST BE SUBMITTED FOR

COR APPROVAL PRIOR TO USE. MODULAR SYSTEMS

MUST PROVIDE THE SAME INFECTION CONTROL AND

FIRE RATING REQUIRED.

R. USE OF MOBILE CONTAINMENT (ICRA) CART IS

ACCEPTABLE FOR ABOVE CEILING WORK THAT CAN

BE LIMITED TO THE CONTAINMENT OF THE CART.

S. TEMPORARY BARRIER SHALL BE INSTALLED FOR

EACH OF THE ROOMS OR CONSTRUCTION AREAS AS

IDENTIFIED WITHIN THE SCOPE OF WORK OF THE

CONTRACT DOCUMENTS.

T. PLASTIC SHEET BARRIERS MAY NOT BE REUSED.

CONTRACTOR SHALL TAKE CARE TO CONTAIN ANY

DUST ON PLASTIC SHEET BARRIERS DURING

REMOVAL AND DISPOSAL.

U. CONSTRUCTED AND/OR MODULAR ICRA BARRIERS

SHALL BE WIPED CLEAN BEFORE REMOVAL TO AVOID

SPREADING DUST.

V. NO MORE THAN 1 CEILING TILE PER 50 SQ.FT. SHALL

BE REMOVED WITHOUT PROPER ICRA AND LIFE

SAFETY MEASURES IN PLACE.

W

AL

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/2

/2

:2

:1

A

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\M S

-3

E

H R

M ls ta rn e s C

B U

M B

.r v t

G-005

CONTRACTOR WORK PROCEDURES

5 86MEL

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 24, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

WVS

3. COORDINATE WITH DIRECTOR OF PHARMACY PRIOR TO ANY ACTIVITY. PHARMACIST MUST BE ON SITE FOR ANY ACTIVITY.

2. NO MORE THAN 1 OPERATING ROOM SHALL BE DOWN AT ANY TIME. WORK SHALL BE COMPLETED WITHIN ONE WORK RESTRICTED NIGHT SHIFT, LEAVING THE SPACE BROOM SWEPT AND READY FOR A VA TERMINAL

CLEAN BY 5:00 AM.

1. NO MORE THAN 4 INPATIENT BEDS WILL BE DOWN AT ONE TIME, UNLESS COORDINATED BY THE COR BASED ON PATIENT CENSUS.

NOTES:

OUTPATIENT CLINICS HIGH X X X X X X X

SLEEP LAB HIGH X X X X X X X X

RETAIL SPACE MEDIUM X X X X

RADIOLOGY / IMAGING HIGH X X X X

MORGUE HIGH X X X X

PHYSICAL THERAPY HIGH X X X X X X

PHARMACY HIGHEST X X X X X NOTE 3 X X X X NOTE 3 X X X X NOTE 3 X X X X NOTE 3

INPATIENT MENTAL HEALTH HIGH X X X X

INPATIENT NURSING UNIT HIGH X X X X NOTE 1 X X X X NOTE 1 X X NOTE 1 X X X X X NOTE 1

ENDOSCOPY HIGHEST X X X X

MEDICAL RECORDS LOW X X X X

LOGISTICS MEDIUM X X X X

LAB / MICROBIOLOGY HIGH X X X X X X X

INFORMATION TECHNOLOGY LOW X X X X

ICU / CRITICAL CARE HIGHEST X X X X NOTE 1 X X X X X NOTE 1 X X X X X NOTE 1 X X X X X NOTE 1

ONCOLOGY / HEMATOLOGY HIGHEST X X X X

SURGERY HIGHEST X X X X X NOTE 2 X X X X X X NOTE 2 X X X X X X X NOTE 2 X X X X X X NOTE 2

DIALYSIS HIGHEST X X X X X

SPECIALTY CLINICS HIGH X X X X X X X

FACILITIES LOW X X X X

ENGINEERING LOW X X X X

EMS MEDIUM X X X X

EMERGENCY DEPARTMENT HIGH X X X X X NOTE 1 X X X X X NOTE 1 X X X X X X X NOTE 1 X X X X X X NOTE 1

EDUCATION LOW X X X X

CANTEEN MEDIUM X X X X X X

DIETARY / FOOD SERVICE MEDIUM X X X X

COMMON AREA LOW X X X X

STERILE PROCESSING HIGHEST X X X X X X X X X X X X X

INTERVENTIONAL CARDIOLOGY HIGHEST X X X X X X X

BIO - MED MEDIUM X X X X X X

ANESTHESIOLOGY HIGH X X X X X

ADMINISTRATION LOW X X X X X

DEPARTMENTS

R

IS

K G

R O

U P

B U

S

IN

E S

S H

O U

R S

(7 :3

A

M

:3

P

M

N

IG

H T

H O

U R

S (5

:3 P

M

:3

A

M

R E

S T

R

IC

T E

D N

IG

H

T H

O U

R S

P

M

A

M

W E

E K

E E

N D

O N

L Y

(F R

ID

A

Y

:3 P

M

M O

N D

A Y

:0

A

M

W E

E K

E N

D O

N L

Y N

IG

H

T H

O U

R S

F

R I, S

A T

S

U N

:3

P

M

:3

A

M

A D

V A

N C

E D

N O

T

IC

E

D O

W N

T

IM

E S

C H

E D

U L

E

S

IN

G L

E M

U L

T

IP

L E

R O

O M

S

N O

IS

E

R E

S T

R

IC

T

IO

N

V A

A P

P R

O V

A L

B U

S

IN

E S

S H

O U

R S

(7 :3 a m

:3 p m

N

IG

H T

H O

U R

S (5

:3 P

M

:3

A

M

R E

S T

R

IC

T E

D N

IG

H

T H

O U

R S

P

M

A

M

W E

E K

E E

N D

O N

L Y

(F R

ID

A

Y

:3 P

M

M O

N D

A Y

:0

A

M

W K

E N

D O

N L

Y N

IG

H

T H

O U

R S

(F R

I, S

A T

S

U N

:3

P

M

:3

A

M

A D

V A

N C

E D

N O

T

IC

E

D O

W N

T

IM

E

S

C H

E D

U L

E

S

IN

G L

E M

U L

T

IP

L E

R O

O M

S

N O

IS

E

R E

S T

R

IC

T

IO

N

V A

A P

P R

O V

A L

B U

S

IN

E S

S H

O U

R S

(7 :3 a m

:3 p m

N

IG

H T

H O

U R

S (5

:3 P

M

:3

A

M

R E

S T

R

IC

T E

D N

IG

H

T H

O U

R S

P

M

A

M

W E

E K

E E

N D

O N

L Y

F

R

ID

A Y

:3

P

M

M O

N D

A Y

:0

A

M

W E

E K

E N

D O

N L

Y N

IG

H

T H

O U

R S

(F R

I, S

A T

S

U N

:3

P

M

:3

A

M

A D

V A

N C

E D

N O

T

IC

E

D O

W N

T

IM

E S

C H

E D

U L

E

S

IN

G L

E

M U

L T

IP

L

E R

O O

M S

N O

IS

E

R E

S T

R

IC

T

IO

N

V A

A P

P R

O V

A L

B U

S

IN

E S

S H

O U

R S

(7 :3 a m

:3 p m

N

IG

H T

H O

U R

S (5

:3 P

M

:3

A

M

R E

S T

R

IC

T E

D N

IG

H

T H

O U

R S

P

M

A

M

W E

E K

E E

N D

O N

L Y

(F R

ID

A

Y

:3 P

M

M O

N D

A Y

:0

A

M

W E

E K

E N

D O

N L

Y N

IG

H

T H

O U

R S

F

R I, S

A T

S

U N

:3

P

M

:3

A

M

A D

V A

N C

E N

O T

IC

E

D O

W N

T

IM

E S

C H

E D

U L

E

S

IN

G L

E

M U

L T

IP

L

E R

O O

M S

N O

IS

E

R E

S T

R

IC

T

IO

N

V A

A P

P R

O V

A L

WORKING HOURS SHUTDOWN CRITERIA REMARKS WORKING HOURS SHUTDOWN CRITERIA REMARKS WORKING HOURS SHUTDOWN CRITERIA REMARKS WORKING HOURS SHUTDOWN CRITERIA REMARKS

TYPE A TYPE C TYPE C TYPE D

W

AL

3 4 5 6

8A

2A

3A

3B

13 14

EXISTING CCTV RACK

EXISTING CCTV RACKEXISTING IT EQUIPMENT

EXISTING IT EQUIPMENT

SEE SITE PLAN FOR CIRCUIT 'A'

4 5

SEE TABLE "CABLE TRAY CAPACITY

PLANNING" ON SHEET ET501. CABLE

TRAY DEPTH TO BE 4".

PROPOSED

TELECOM ROOM

A. CONTRACTOR IS RESPONSIBLE FOR TAKING

NEW DATA DROPS TO DESIGNATED ROOMS

ACCORDING TO SCHEDULE. REFER TO

SPECIFICATION SECTION 271510, APPENDIX 1,

FOR DATA DROP SCHEDULE. PLAN IS

INTENDED FOR ROUTING AND DISTANCES.

B. SEE ET DRAWINGS FOR MORE INFORMATION

ON THE FIBER REQUIREMENTS.

C. CONTRACTOR SHALL DETERMINE EXACT

ROUTING IN FIELD.

D. ALL EXISTING CONDITIONS, CONDUIT, AND

DEVICES ARE BASED ON BEST AVAILABLE

INFOMATION AT TIME OF ENGINEERING

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

E. DEVICES WITH LIGHT/GREY LINES ARE

EXISTING TO REMAIN.

F. REPAIR/REPLACE CEILING TILES DAMAGED

DURING CONSTRUCTION AT NO EXTRA COST

TO THE GOVERNMENT.

G. ALL FIBER SHALL BE LABELED EVERY 20 FEET

WITH ‘CKT A’ OR ‘CKT B’ AND TELECOM ROOM

NUMBER. SEE FIBER CABEL LABELING

SCHEME DETAIL.

H. PROVIDE J-HOOKS AND/OR CONDUITS IN

LOCATIONS WHERE NEW CABLE TRAY ROUTE

AND SIZE ISN’T VIABLE. NEW J-HOOKS

AND/OR CONDUIT TO COMPLETE/SUPPORT

CABLE ROUTING BACK TO TELECOM ROOM

WITH PROPOSED CONNECTED RACK. SEE J-

HOOK SPACING REQUIREMENTS DETAIL.

I. THIS SHEET SPECIFIES OVERALL WORK

RELATED TO ELECTRICAL AND TECHNOLOGY

ROUTING, FIRE PENETRATIONS AND

ARCHITECTURAL SHEETS. GENERAL

CONTRACTOR IS RESPONSIBLE FOR

ENSURING APPLICABLE DISCIPLINES COVER

WORK ASSOCIATED WITH THESE SHEETS.

J. PROVIDE FIRE/SMOKE RATED FIRE SLEEVE

ASSEMBLIES (RATED AT 2 HOURS). SEAL

FLOOR OPENING AFTER FIBER IS INSTALLED

AND TESTED.

K. FIRE STOP AND SMOKE STOP ALL NEW AND

RE-USED PENETRATIONS THROUGH RATED

PARTITIONS.

L. ALL FLOOR PENETRATION TO BE ASSUMED 2

HOUR RATED.

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:3

:1

P

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\E T

-3

V A

A le x a n d ri a E

H R

M

B ld g ls ta rn e s C

B U

M B

.r v t

001.G-101

BUILDING 1, BASEMENT OVERALL PLAN

6 86LAS

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 20, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

VARIOUS

KTK

Scale: 3/16" = 1'-0"

BUILDING 1, BASEMENT OVERALL PLAN

N O

R T H0 42 8

CABLE TRAY LEGEND

1 PROPOSED ROUTING OF FIBER. CONTRACTOR TO

VERIFY ROUTING. FIBER IS TO BE RAN INSIDE OF

INNERDUCT AND SUPPORTED EVERY 5'-0" WITH

J-HOOKS.

2 EXISTING OI&T CLOSET, ONCE ALL DATA CABLING

SERVICED OUT OF THIS CLOSET IS REPLACED.

CONFIRM WITH OI&T THAT NO ACTIVE DATA

DROPS ARE SERVED OUT OF THE CLOSET. UPON

CONFIRMATION, COORDINATE FOR REMOVAL OF

ALL VA OWNED NETWORK SWITCHES. REMOVE

PATCH PANELS AND ALL ASSOCIATED CABLING

SERVED FROM DEMOLISHED CLOSET. BID

DEMOLITION AND DISPOSAL OF IT RACK AND ANY

NON-DATA COMPONENTS THAT ARE HOUSED IN

THE RACK. LEAVE THE RACK IN PLACE WITH UPS

POWER.

3 INSTALL NEW PATCH PANEL AT OLD IT CLOSET

AND NEW CLOSET. PROVIDE AND INSTALL PATCH

CABLING FOR ALL SPECIAL SYSTEMS CONTAINED

IN THE CLOSET.

4 PROVIDE (4) 4” FIRE/SMOKE SLEEVE ASSEMBLY (2

HOUR) FOR THE FIBER OPTIC RISER FOR

CIRCUITS A & B. SEE BUILDING FIBER RISER

DIAGRAM FOR MORE INFORMATION. COORDINATE

ALL WORK.

5 PROVIDE (4) 4" CONDUIT STUBS FROM HAND HOLE

TO 6" INSIDE BUILDING.

6 PROVIDE HAND HOLE WITHIN 5' OF BUILDING

EXTERIOR WALL. REFERENCE HAND HOLE DETAIL

ON TELECOMMUNICATIONS HANDHOLE DETAIL

FOR MORE INFORMATION.

7 SEE CIVIL DRAWING(S) FOR CONTINUATION.

8 PROVIDE (2) 4" CORE DRILL OPENINGS WITH UL

APPROVED FIRE/SMOKE SLEEVE ASSEMBLIES (2

HOUR) FOR THE FIBER OPTIC RISER FOR

CIRCUITS A & B. SEE BUILDING FIBER RISER

DIAGRAM FOR MORE INFORMATION. COORDINATE

ALL WORK.

9 PROVIDE (2) 4" CORE DRILL OPENINGS WITH UL

APPROVED FIRE/SMOKE SLEEVE ASSEMBLIES (2

HOUR) FOR THE FIBER OPTIC RISER FOR CAT 6A

CABLES. COORDINATE ALL WORK.

10 PROPOSED PATHWAY ROUTES. SURVEY AND SITE

OBSERVATION SHOWS A LIMITED CLEARANCE

ABOVE THE CEILING IN THESE AREAS. PROVIDE

J-HOOKS AS REQUIRED TO SUPPORT ALL

CABLING. CONTRACTOR TO VERIFY EXISTING

CONDITIONS.

11 PROVIDE (4) 4" CONDUITS FROM HAND HOLE TO

BUILDING.

Docusign Envelope ID: 31EDC0F6-5827-45E5-8E99-758108BAC466

3/23/2026 3/23/2026

Date

MARCH 24, 2026

GFI

WP

E E

LOBBY

NURSING

CONFERENCE

ROOM

UNIT

SUPERVISOR

SECRETARY

NURSING

EXECUTIVE

120A

PROGRAM

ASSISTANT

120B

NURSING

ADMIN.

AREA

TIME

KEEPER

119B

EQUIPMENT

ROOM

119A

ASSOC.

CHIEF

NURSE

ADMINISTRATIVE

ASSISTANT

STORAGE

MALE

FEMALE

HRM

MANAGER

SECRETARY

AAC

HRM

ADMINISTRATION

AREA

CLERK

109A

CLERK

109B

CLERK

CLERK

PMS

PMS

PANEL 'N115'

PANEL 'E11'

001.ET401

001.MP401

001.A-401

LIMIT OF COVERAGE FOR TR 103

PANEL 'N11N'

01-1-CU-1 01-1-CU-2

8 8

TR

'B'-4

'A'-8,10 'A'-8,10

SEE TABLE "CABLE TRAY CAPACITY

PLANNING" ON SHEET ET501. CABLE

TRAY DEPTH TO BE 4".

PROPOSED

TELECOM ROOM

A. CONTRACTOR IS RESPONSIBLE FOR TAKING

NEW DATA DROPS TO DESIGNATED ROOMS

ACCORDING TO SCHEDULE. REFER TO

SPECIFICATION SECTION 271510, APPENDIX 1,

FOR DATA DROP SCHEDULE. PLAN IS

INTENDED FOR ROUTING AND DISTANCES.

B. SEE ET DRAWINGS FOR MORE INFORMATION

ON THE FIBER REQUIREMENTS.

C. CONTRACTOR SHALL DETERMINE EXACT

ROUTING IN FIELD.

D. ALL EXISTING CONDITIONS, CONDUIT, AND

DEVICES ARE BASED ON BEST AVAILABLE

INFOMATION AT TIME OF ENGINEERING

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

E. DEVICES WITH LIGHT/GREY LINES ARE

EXISTING TO REMAIN.

F. REPAIR/REPLACE CEILING TILES DAMAGED

DURING CONSTRUCTION AT NO EXTRA COST

TO THE GOVERNMENT.

G. ALL FIBER SHALL BE LABELED EVERY 20 FEET

WITH ‘CKT A’ OR ‘CKT B’ AND TELECOM ROOM

NUMBER. SEE FIBER CABEL LABELING

SCHEME DETAIL.

H. PROVIDE J-HOOKS AND/OR CONDUITS IN

LOCATIONS WHERE NEW CABLE TRAY ROUTE

AND SIZE ISN’T VIABLE. NEW J-HOOKS

AND/OR CONDUIT TO COMPLETE/SUPPORT

CABLE ROUTING BACK TO TELECOM ROOM

WITH PROPOSED CONNECTED RACK. SEE J-

HOOK SPACING REQUIREMENTS DETAIL.

I. THIS SHEET SPECIFIES OVERALL WORK

RELATED TO ELECTRICAL AND TECHNOLOGY

ROUTING, FIRE PENETRATIONS AND

ARCHITECTURAL SHEETS. GENERAL

CONTRACTOR IS RESPONSIBLE FOR

ENSURING APPLICABLE DISCIPLINES COVER

WORK ASSOCIATED WITH THESE SHEETS.

J. PROVIDE FIRE/SMOKE RATED FIRE SLEEVE

ASSEMBLIES (RATED AT 2 HOURS). SEAL

FLOOR OPENING AFTER FIBER IS INSTALLED

AND TESTED.

K. FIRE STOP AND SMOKE STOP ALL NEW AND

RE-USED PENETRATIONS THROUGH RATED

PARTITIONS.

L. ALL FLOOR PENETRATION TO BE ASSUMED 2

HOUR RATED.

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:3

:1

P

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\E T

-3

V A

A le x a n d ri a E

H R

M

B ld g ls ta rn e s C

B U

M B

.r v t

001.G-111

BUILDING 1, FIRST FLOOR OVERALL

PLAN

7 86LAS

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 20, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

VARIOUS

KTK

Scale: 3/16" = 1'-0"

BUILDING 1, FIRST FLOOR OVERALL PLAN

N O

R T H0 42 8

CABLE TRAY LEGEND

11 PROVIDE (2) 4" CORE DRILL OPENINGS WITH UL

APPROVED FIRE/SMOKE SLEEVE ASSEMBLIES (2

HOUR) FOR THE FIBER OPTIC RISER FOR CAT 6A

CABLES. COORDINATE ALL WORK.

12 FIBER CABLING CONTINUES INTO CONNECTING

CORRIDOR TO NEXT BUILDING. CONTRACTOR TO

VERIFY ROUTING. FIBER IS TO BE RAN INSIDE OF

INNERDUCT AND SUPPORTED EVERY 5'-0" WITH

J-HOOKS.

1 EXISTING FIRE ALARM ANNUNCIATOR PANEL

(EDWARDS E5 T3).

2 EXISTING OI&T CLOSET, ONCE ALL DATA CABLING

SERVICED OUT OF THIS CLOSET IS REPLACED.

CONFIRM WITH OI&T THAT NO ACTIVE DATA

DROPS ARE SERVED OUT OF THE CLOSET. UPON

CONFIRMATION, COORDINATE FOR REMOVAL OF

ALL VA OWNED NETWORK SWITCHES. REMOVE

PATCH PANELS AND ALL ASSOCIATED CABLING

SERVED FROM DEMOLISHED CLOSET. BID

DEMOLITION AND DISPOSAL OF IT RACK AND ANY

NON-DATA COMPONENTS THAT ARE HOUSED IN

THE RACK. LEAVE THE RACK IN PLACE WITH UPS

POWER.

3 INSTALL NEW PATCH PANEL AT OLD IT CLOSET

AND NEW CLOSET. PROVIDE AND INSTALL PATCH

CABLING FOR ALL SPECIAL SYSTEMS CONTAINED

IN THE CLOSET.

4 PROVIDE (2) 4" CORE DRILL OPENINGS WITH UL

APPROVED FIRE/SMOKE SLEEVE ASSEMBLIES (2

HOUR) FOR THE FIBER OPTIC RISER FOR

CIRCUITS A & B. SEE BUILDING 1 FIBER RISER

DIAGRAM FOR MORE INFORMATION. COORDINATE

ALL WORK.

5 CABLES AND/OR CABLE TRAY CANNOT RUN

ABOVE CEILING IN THIS AREA.

6 PROPOSED PATHWAY ROUTES. SURVEY AND SITE

OBSERVATION SHOWS A LIMITED CLEARANCE

ABOVE THE CEILING IN THESE AREAS. PROVIDE

J-HOOKS AS REQUIRED TO SUPPORT ALL

CABLING. CONTRACTOR TO VERIFY EXISTING

CONDITIONS.

7 ROUTE CABLES FROM THIS SIDE OF FLOOR

BELOW THEN UP TO NEW TELECOM ROOM ON

THIS FLOOR.

8 PROVIDE NEMA 3R 30A FUSED DISCONNECT AND

CODE REQUIRED WP GFI OUTLET. POWER

CONDENSING UNIT FROM PANEL ‘A’ OF THE TR

THAT IT IS SERVING. USE 2P-20A CIRCUIT

BREAKER.

9 EXISTING GENERAL ELECTRIC NAB 225A, MLO

PANEL ‘E11’ TO SERVE NEW TR ROOM CRITICAL

POWER PANEL IN ROOM TR-103. PROVIDE ONE

60A 3 POLE GE TEB CIRCUIT BREAKER IN SPACE

22, 24, 26 AND CIRCUIT TO PANEL IN TR USING 3-2

AWG, 1-1 AWG NEU, 1-8 AWG EG IN 1-1/2”

CONDUIT.

10 EXISTING GENERAL ELECTRIC NLAB 225A, MLO

PANEL ‘N115’ TO SERVE NEW TR ROOM NORMAL

POWER PANEL IN ROOM TR-103. REMOVE

EXISTING 20A SPARE BREAKERS FROM 14, 16, 18.

PROVIDE ONE 60A 3 POLE GE THQB CIRCUIT

BREAKER IN SPACE 14, 16, 18 AND CIRCUIT TO

PANEL IN TR USING 3-2 AWG, 1-1 AWG NEU, 1-8

AWG EG IN 1-1/2” CONDUIT.

# KEY NOTES:

Docusign Envelope ID: 31EDC0F6-5827-45E5-8E99-758108BAC466

3/23/2026 3/23/2026

DIRECTOR

204E

ADMIN

ASSISTANT

DIRECTOR

OFFICE

204D

NURSE

EXECTUTIVE

SECTRETARY

203A

CONFERENCE

ROOM

CSO

BREAK

ROOM

CSO

OFFICE

AACOS

OFFICE

COS

SECRETARY

OFFICE

COPY

ROOM

213A

CAC

OFFICE

213B

SECRETARY

OFFICE

CHEIF

OF

STAFF

212A

CONFERENCE

ROOM

PUBLIC

AFFAIRS

MALE

TOILET

TOILET

207C

FEMALE

TOILET

207A

EMS

207B

ENTRY

KITCHEN

DIRECTOR'S

ADMIN

SUPPORT

SECRETARY

OFFICE

204B

SECRETARY

OFFICE

204C

ASSOCIATE

DIRECTOR

204F

S T

A

IR

S D

O W

N

S T

A

IR

S U

P

BATHROOM

204G

NURSE

EXECUTIVE

OFFICE

FILE

ROOM

LIMIT OF COVERAGE FOR TR 202

001.ET402

001.MP402

001.A-402

EXISTING

PANEL 'E12'EXISTING

PANEL 'N12'

SEE TABLE "CABLE TRAY CAPACITY

PLANNING" ON SHEET ET501. CABLE

TRAY DEPTH TO BE 4".

PROPOSED

TELECOM ROOM

A. CONTRACTOR IS RESPONSIBLE FOR TAKING

NEW DATA DROPS TO DESIGNATED ROOMS

ACCORDING TO SCHEDULE. REFER TO

SPECIFICATION SECTION 271510, APPENDIX 1,

FOR DATA DROP SCHEDULE. PLAN IS

INTENDED FOR ROUTING AND DISTANCES.

B. SEE ET DRAWINGS FOR MORE INFORMATION

ON THE FIBER REQUIREMENTS.

C. CONTRACTOR SHALL DETERMINE EXACT

ROUTING IN FIELD.

D. ALL EXISTING CONDITIONS, CONDUIT, AND

DEVICES ARE BASED ON BEST AVAILABLE

INFOMATION AT TIME OF ENGINEERING

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

E. DEVICES WITH LIGHT/GREY LINES ARE

EXISTING TO REMAIN.

F. REPAIR/REPLACE CEILING TILES DAMAGED

DURING CONSTRUCTION AT NO EXTRA COST

TO THE GOVERNMENT.

G. ALL FIBER SHALL BE LABELED EVERY 20 FEET

WITH ‘CKT A’ OR ‘CKT B’ AND TELECOM ROOM

NUMBER. SEE FIBER CABEL LABELING

SCHEME DETAIL.

H. PROVIDE J-HOOKS AND/OR CONDUITS IN

LOCATIONS WHERE NEW CABLE TRAY ROUTE

AND SIZE ISN’T VIABLE. NEW J-HOOKS

AND/OR CONDUIT TO COMPLETE/SUPPORT

CABLE ROUTING BACK TO TELECOM ROOM

WITH PROPOSED CONNECTED RACK. SEE J-

HOOK SPACING REQUIREMENTS DETAIL.

I. THIS SHEET SPECIFIES OVERALL WORK

RELATED TO ELECTRICAL AND TECHNOLOGY

ROUTING, FIRE PENETRATIONS AND

ARCHITECTURAL SHEETS. GENERAL

CONTRACTOR IS RESPONSIBLE FOR

ENSURING APPLICABLE DISCIPLINES COVER

WORK ASSOCIATED WITH THESE SHEETS.

J. PROVIDE FIRE/SMOKE RATED FIRE SLEEVE

ASSEMBLIES (RATED AT 2 HOURS). SEAL

FLOOR OPENING AFTER FIBER IS INSTALLED

AND TESTED.

K. FIRE STOP AND SMOKE STOP ALL NEW AND

RE-USED PENETRATIONS THROUGH RATED

PARTITIONS.

L. ALL FLOOR PENETRATION TO BE ASSUMED 2

HOUR RATED.

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg. of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:3

:1

P

M C

U s e rs \l s ta rn e s \D o c u m e n ts

\E T

-3

V A

A le x a n d ri a E

H R

M

B ld g ls ta rn e s C

B U

M B

.r v t

001.G-121

BUILDING 1, SECOND FLOOR OVERALL

PLAN

8 86LAS

ELECTRONIC HEALTH

RECORD MODERNIZATION

(EHRM)

ALEXANDRIA VA HEALTH CARE SYSTEM

2495 SHREVEPORT HWY, 71N

PINEVILLE, LA 71360

MARCH 20, 2026

100% CONSTRUCTION DOCUMENTS

502-21-22220-398

VARIOUS

KTK

Scale: 3/16" = 1'-0"

BUILDING 1, SECOND FLOOR OVERALL PLAN

N O

R T H0 42 8

CABLE TRAY LEGEND

1 PROPOSED PATHWAY ROUTES. SURVEY AND SITE

OBSERVATION SHOWS A LIMITED CLEARANCE

ABOVE THE CEILING IN THESE AREAS. PROVIDE

J-HOOKS AS REQUIRED TO SUPPORT ALL

CABLING. CONTRACTOR TO VERIFY EXISTING

CONDITIONS.

2 PROVIDE (2) 4" CORE DRILL OPENINGS WITH UL

APPROVED FIRE/SMOKE SLEEVE ASSEMBLIES (2

HOUR) FOR THE FIBER OPTIC RISER FOR

CIRCUITS A & B. BUILDING 1 FIBER RISER

DIAGRAM FOR MORE INFORMATION. COORDINATE

ALL WORK.

3 INSTALL NEW PATCH PANEL AT OLD IT CLOSET

AND NEW CLOSET. TERMINATE AT PATCH PANEL

FOR DESIGNATION.

4 PROVIDE (2) 4” FIRE/SMOKE SLEEVE ASSEMBLY (2

HOUR) FOR THE FIBER OPTIC RISER FOR

CIRCUITS A & B. SEE BUILDING 1 FIBER RISER

DIAGRAM FOR MORE INFORMATION. COORDINATE

ALL WORK.

5 EXISTING GENERAL ELECTRIC NLAB 225A, MLO

PANEL ‘N12’ TO SERVE NEW TR ROOM NORMAL

POWER PANEL IN ROOM TR-202. PROVIDE ONE

60A 3 POLE GE THQB CIRCUIT BREAKER IN PANEL

AND CIRCUIT TO PANEL IN TR USING 3-2 AWG, 1-1

AWG NEU, 1-8 AWG EG IN 1 1/2” CONDUIT.

6 EXISTING GENERAL ELECTRIC NAB 225A, MLO

PANEL ‘E12’ TO SERVE NEW TR ROOM CRITICAL

POWER PANEL IN ROOM TR-202. PROVIDE ONE

60A 3 POLE GE TEB CIRCUIT BREAKER IN PANEL

AND CIRCUIT TO PANEL IN TR USING 3-2 AWG, 1-1

AWG NEU, 1-8 AWG EG IN 1 1/2” CONDUIT.

Docusign Envelope ID: 31EDC0F6-5827-45E5-8E99-758108BAC466

3/23/2026 3/23/2026

NURSING

EDUCATION

EDUCATION

SERVICES

CORRIDOR

LOBBY

LOBBY

101A

DIR.

OFFICE

STAIRS

1SC-2

UNION

OFF.

STORAGE

131A

TLT.

NURSE

CLASSROOM

NURSE

CLASSROOM

DVB

LOCK

DVB

LIN. CL.

ELEC.

CL.

105A

STAIRS

1SS-2

TOILET

H.K CL.

STOR.

117K

BR. RM

117J

ELETR.

117H

OFFICE

117G

CHIEF

PSYCH

117F

SECRE.

117E

WAITING

RM

117D

OFFICE

117C

OFFICE

117B

OFFICE

117A

OFFICE

116A

OFFICE

MALE

TOILET

STORAGE

NURSE

NURSE

EDUC.

NURSE

EDUC.

DIR.

ESHCL

TRASH

MAINT

ONOCOLOGY

FAC.

MAN.

VALEX

STORAGE

STAIRS

1SN-2

MRA

128H

ENTRY

CIRCUL.

DESK

128A

STORAGE

128C

WORK

RM.

128B

RESTROOM

128D

LIBRARY

128E

CON. RM.

128F

CHIEF

128G

WK RM

VALEX

ADMIN.

127A

VAULT

127B

TOILET

126C OFFICE

126D

OFFICE

126E

COOR.

127C

COM.

RM.

126A

CON. RM.

126B

LIMIT OF COVERAGE FOR TR 133

002.ET401

002.MP401

002.A-401

TR

EXISTING

PANEL

'N-2-G-S-1'

EXISTING

PANEL

'N-2-G-S-2'

EXISTING

PANEL 'G/SX' 4

SEE TABLE "CABLE TRAY CAPACITY

PLANNING" ON SHEET ET501. CABLE

TRAY DEPTH TO BE 4".

PROPOSED

TELECOM ROOM

A. CONTRACTOR IS RESPONSIBLE FOR TAKING

NEW DATA DROPS TO DESIGNATED ROOMS

ACCORDING TO SCHEDULE. REFER TO

SPECIFICATION SECTION 271510, APPENDIX 1,

FOR DATA DROP SCHEDULE. PLAN IS

INTENDED FOR ROUTING AND DISTANCES.

B. SEE ET DRAWINGS FOR MORE INFORMATION

ON THE FIBER REQUIREMENTS.

C. CONTRACTOR SHALL DETERMINE EXACT

ROUTING IN FIELD.

D. ALL EXISTING CONDITIONS, CONDUIT, AND

DEVICES ARE BASED ON BEST AVAILABLE

INFOMATION AT TIME OF ENGINEERING

SURVEY AND VISUAL INSPECTION. VERIFY

EXISTING CONDITIONS.

E. DEVICES WITH LIGHT/GREY LINES ARE

EXISTING TO REMAIN.

F. REPAIR/REPLACE CEILING TILES DAMAGED

DURING CONSTRUCTION AT NO EXTRA COST

TO THE GOVERNMENT.

G. ALL FIBER SHALL BE LABELED EVERY 20 FEET

WITH ‘CKT A’ OR ‘CKT B’ AND TELECOM ROOM

NUMBER. SEE FIBER CABEL LABELING

SCHEME DETAIL.

H. PROVIDE J-HOOKS AND/OR CONDUITS IN

LOCATIONS WHERE NEW CABLE TRAY ROUTE

AND SIZE ISN’T VIABLE. NEW J-HOOKS

AND/OR CONDUIT TO COMPLETE/SUPPORT

CABLE ROUTING BACK TO TELECOM ROOM

WITH PROPOSED CONNECTED RACK. SEE J-

HOOK SPACING REQUIREMENTS DETAIL.

I. THIS SHEET SPECIFIES OVERALL WORK

RELATED TO ELECTRICAL AND TECHNOLOGY

ROUTING, FIRE PENETRATIONS AND

ARCHITECTURAL SHEETS. GENERAL

CONTRACTOR IS RESPONSIBLE FOR

ENSURING APPLICABLE DISCIPLINES COVER

WORK ASSOCIATED WITH THESE…

This is the start of the file's text. The full file is on GovTribe.