Attachment 19 - 2023-09-29 544-329 BID DRAWINGS_Part6.pdf
PDF 20 MB Posted
- Solicitation number
- 36C77624R0028
About this file
This document appears to be Attachment 19 - 2023-09-29 544-329 BID DRAWINGS_Part6.pdf, which contains bid drawings related to a federal contract opportunity from the Department of Veterans Affairs Technology Acquisition Center Austin.
The federal contract opportunity is for a project to construct a new, 15,000 gross square foot optometric facility at the William Jennings Bryan Dorn VA Medical Center in Columbia, SC. The project will include new construction, HVAC, utility work, interior finishes, utility coordination, site work, underground storm water detention, asbestos and lead survey and abatement, and communication utility work inside an active hospital. The solicitation number is 36C77624R0028, and the opportunity type is a Solicitation.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOFTOP UNIT ROOF CURB (DOWN FLOW
DISCHARGE)
ROOFTOP UNIT
FLASHING &
COUNTER
FLASHING BY MC.
DUCT OPENING
DISCONNECT
BY EC.
COORDINATE
LOCATION
FLEXIBLE CONDUIT
BY EC.
ROOFING BY
OTHERS
NOTES:
1. ROOF CURB SHALL BE A MINIMUM HEIGHT OF 14".
2. GENERAL CONTRACTOR SHALL COORDINATE LOCATIONS OF ROOF
PENETRATIONS WITH STRUCTURE.
3. MECHANICAL CONTRACTOR SHALL PROVIDE TREATED LUMBER,
CUSTOM TRIMMED TO LEVEL THE ROOF CURB. MECHANICAL
CONTRACTOR SHALL COORDINATE WORK WITH GENERAL
CONTRACTOR.
4. SEAL ALL ROOF PENETRATIONS LOCATED BELOW THE RTU, WITHIN
THE ROOF CURB, WITH SOUND DEADENING TAPE.
MISC. STEEL
SUPPORT BY GC.
ROOF OPENINGS
SUPPLY AND
RETURN DUCT
W/FLEX
CONNECTOR
ROOFTOP UNIT
DUCT MOUNTED
SMOKE DETECTOR,
SIX EQUIVALENT
DUCT DIAMETERS
FROM ELBOW
CEILING
RETURN
DUCT
SUPPLY DUCT
ROOF TOP UNIT
FLEXIBLE
DUCT
CONNECTION
TYP.
ROOF
ROOF CURB
PROVIDED BY
RTU
MANUFACTURER.
NTS
NOTES:
1. PIPE CONDENSATE DRAIN AS SHOWN ON MH100A AND MH100B.
SUPPORT DRAIN ON TREATED WOOD BLOCKS EVERY FOUR FEET.
NTS
PIPING THRU CURBED ROOF OPENING
INSULATED INSIDE
OF COVER WITH
3/4" ARMAFLEX
SUBMIT COMPLETE
SHOP DRAWINGS
ON CURB ASSEMBLY
INSULATED PIPING
WITH ALUMINUM
JACKET
FURNISH AND INSTALL A PORTALS PLUS PIPE PORTAL
AS MANUFACTURED BY PORTALS PLUS FOR PIPE
PENETRATION THRU ROOF. SYSTEM SHALL INCLUDE A
8"H PREFAB CURB WITH CURB COVER WITH
PRE-PUNCHED MOUNTING HOLES AND MOLDED
SEALING RINGS ON A COLLARED OPENING.
COMPRESSION MOLDED CAP SHALL BE EPDM WITH
STAINLESS STEEL CLAMPS.
INSULATION
ROOF STRUCTURE
ROOF CURB
PROVIDED BY RTU
MANUFACTURER.
20 19 17 16 15 14 13 12 11 9 8
2 1
5 4 3 6
R.A.S.A.
20 19 18 17 16 14 13 11 10 75 4 3 6
PIPING
CABINET
M
M
M
M
E.A.
M
R.A.
O.A.
FAN
EXHAUST
FAN
SUPPLY
PLAN VIEW
NTS
RTU SCHEMATICS
NTS
SIDE VIEW
F RATING = 2 AND 3 HR.
T RATING = 0-HR.
SYSTEM NO. C-AJ-1421
TOP VIEW SECTION A-A
1. FLOOR OR WALL ASSEMBLY -- MIN 4-1/2 IN. (114 MM) THICK REINFORCED LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. FLOOR MAY ALSO BE CONSTRUCTED OF ANY MIN 6 IN. THICK UL CLASSIFIED HOLLOW-CORE
PRECAST CONCRETE UNITS*.
SEE CONCRETE BLOCKS (CAZT) CATEGORIES IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF MANUFACTURERS.
2. METALLIC SLEEVE - (OPTIONAL) NOM. 6 IN. (152 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL SLEEVE CAST OR
GROUTED INTO FLOOR OR WALL ASSEMBLY, FLUSH WITH FLOOR OR WALL SURFACES.
3. THROUGH-PENETRANT - ONE METALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY
WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, TUBE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE 0 IN. (0MM) (POINT CONTACT) TO MAX 5-3/8 IN. (137 MM). PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF FLOOR OR WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF METALLIC PIPES OR CONDUITS MAY BE USED:
A. STEEL PIPE - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
B. IRON PIPE - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
C. COPPER PIPE - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE.
D. COPPER TUBING - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING.
E. CONDUIT - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) STEEL CONDUIT.
F. CONDUIT - NOM. 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING (EMT).
4. FIRESTOP SYSTEM -- THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING:
A. PACKING MATERIAL -- MIN 4 IN. (102 MM) THICKNESS OF MIN 4 PCF (64 KG/M3) MINERAL WOOL BATT INSULATION FIRMLY
PACKED INTO OPENING AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM BOTTOM OR TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF FILL MATERIAL.
B. FILL, VOID OR CAVITY MATERIAL* -- MIN 1/2 IN. (13 MM) THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULUS, FLUSH WITH BOTTOM OR TOP SURFACE OF FLOOR OR WITH BOTH SURFACES OF WALL . A MIN 1/2 IN. (13 MM) DIAM BEAD OF CAULK
SHALL BE APPLIED AT THE POINT CONTACT LOCATION BETWEEN PIPE AND SLEEVE/CONCRETE.
HILTI CONSTRUCTION CHEMICALS, DIV OF HILTI INC -- FS ONE SEALANT
*BEARING THE UL CLASSIFICATION MARK
A
1 4a 4b
22A
UL FLOOR OR WALL ASSEMBLY PENETRATION
NTS
7 1
RTU-1/2 = 477 3/4"
104 1/2"
EXHAUST
DUCT
RTU AND CHILLED WATER PUMPING
PACKAGE ENCLOSURE CURB MOUNTING NTS 3
ROOF DECK
CURB GASKETING
ROOFTOP UNIT
PREFABRICATED
ROOF CURB BY RTU
MANUFACTURER
14" MIN
POS# MODULE
1 AIR MIXING SECTION
2 CUSTOM LENGTH SECTION
3 ACCESS SECTION
4 FILTER SECTION
5 AIR MIXING SECTION
6 EXHAUST FAN SECTION
7 AIR TO AIR HEAT EXCHANGER SECTION
8 AIR MIXING SECTION
9 AIR MIXING SECTION
10 ACCESS SECTION
11 ELECTRIC HEATING COIL SECTION
12 ACCESS SECTION
13 COOLING COIL SECTION
14 ACCESS SECTION
15 SUPPLY FAN SECTION
16 ACCESS SECTION
17 SILENCER
18 ACCESS SECTION
19 FILTER SECTION
20 CONTROLS SECTION
M
M
NOTES:
1. ROOFTOP UNIT DIMENSIONS MAY VERY PER
MANUFACTURER. CONTRACTOR IS RESPONSIBLE
TO MAKE ALL REQUIRED CHANGES AND
COORDINATE UNIT SUPPORT WITH STRUCTURAL
BELOW. VERIFY WITH ENGINEER IN SUBMITTAL
PROCESS PRIOR TO ANY CHANGES.
NTS
RTU PIPING CABINET 4
CHILLED WATER
PIPING ON ROOF
WITH SUPPORT. SEE
DETAIL 12/M002.
RTU PIPING CABINET (TYP. FOR TWO)
HINGED
ACCESS DOOR
PREMANUFACTURED
RTU ROOF CURB
M
OA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/9
/2
:1
:4
P
M
M002A
MECHANICAL - DETAILS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
08/18/2022 GAT CACRevisions: Date:
YES
YES
NO
YES
YES
8570 (4285)
VARIABLE VOLUME
CUSTOM
1ST FLOOR
ROOF
RTU-1
YES
YES
YES
1660/8570
FRONT TOP
YES
MERV 16A
12" CARTRIDGE
(2) 20"x20" AND (4)20"X24"
MERV 8
2" PLEATED
18.89
PLENUM
II
DIRECT
3.5
22.25
56.21
1.067
8.24
PER MANUFACTURER
16.81
CHILLED WATER
394.88
282.79
0.166
ELECTRIC
14.58
92.10
MERV 8
28.89
0.494
II
BACK TOP
YES
DIRECT
PLENUM
16.5
2.0
RTU-2
ROOF
1ST FLOOR
CUSTOM
VARIABLE VOLUME
1660/8570
MERV 8
28.89
0.494
394.88
282.79
79/65
49/48
56.21
1.067
8.24
PER MANUFACTURER
16.81
CHILLED WATER
YES
YES
MERV 16A
12" CARTRIDGE
18.89
YES
YES
NO
YES
YES
YES
8570 (4285)
2.0
16.5
DIRECT
PLENUM
II
BACK TOP
YES
FRONT TOP
YES
PLENUM
II
DIRECT
3.5
22.25
2" CARTRIDGE 2" CARTRIDGE
8570 8570
2 @ 10/460/3Ø/60
20/460/3Ø/60
FAN SIZED FOR
ECONOMIZER
YES YES
UNIT WEIGHT: (LBS)
GENERAL NOTES:
1. INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH MANUFACTURER'S INSTALLATION
RECOMMENDATIONS. INSULATE WITH 1" THICK FLEXIBLE ELASTOMETRIC TYPE OF INSULATION.
PROVIDE PIPING APPURTENANCES AS REQUIRED.
2. UNIT SHALL BE PROVIDED WITH THE FOLLOWING FACTORY INSTALLED ACCESSORIES: (MODEL
NUMBER WILL REFLECT SOME OF THESE ACCESSORIES BUT NOT NECESSARILY ALL)
· AUTO RESTART
· DEHUMIDIFICATION MODE
· CLEANABLE FILTERS
· WALL MOUNTED THERMOSTAT.
· PROVIDE UNIT WITH LOW AMBIENT COOLING.
3.
4.
TYPE REFRIGERANT SHALL BE R-410A
5.
REFER TO SPECIFICATIONS FOR SEQUENCE OF OPERATION FOR SPLIT SYSTEMS.
6.
INDOOR UNIT SHALL BE POWERED FROM OUTDOOR UNIT.
7.
PROVIDE EVAPORATOR UNITS WITH INTEGRAL CONDENSATE PUMP.
INSTALL EVAPORATIVE UNITS HIGH ON WALL AND EXTEND AND TERMINATE EACH OF CONDENSATE DRAINS PER THE DRAWINGS.
HSPF (BTU/H/W)
TOTAL INPUT (W)
TOTAL HEATING CAPACITY (MBH)
COOLING EDb/EWb (°F)
GROSS COOLING CAP (MBH)
TOTAL CFM
UNIT TAG:
SEER
LOCATION
SYSTEM DESCRIPTION
ELECTRICAL CONNECTION (MCA/MOCP)
ELECTRICAL CHARACTERISTICS
CU-2 AC-2
CONDENSING UNIT EVAPORATOR UNIT
DUCTLESS SPLIT SYSTEM
163 46
ROOF
SPLIT SYSTEM
COOLING ONLY
SPLIT SYSTEM
COOLING ONLY
COMM 1A016
CU-1 AC-1
CONDENSING UNIT EVAPORATOR UNIT
DUCTLESS SPLIT SYSTEM
163 46
ROOF
1,940 705
17.0 17.0
80/6795/75
N/A
2,270 2,270
N/A N/A
N/A
208V/1
18/30 SEE NOTE 6
SPLIT SYSTEM
COOLING ONLY
208V/1
SPLIT SYSTEM
COOLING ONLY
COMM 1A102
1,940 705
17.0 17.0
80/6795/75
N/A
2,270 2,270
N/A N/A
N/A
208V/1
18/30 SEE NOTE 6
208V/1∅ ∅
0.166
ELECTRIC
14.58
92.10
MERV8
2" PLEATED
(2) 20"x20" AND (4)20"X24"
79/65
49/48
C O
O L
IN
G C
O
IL
A C
C E
S S
S
U P
P L Y
F A
N F
IN
A
L F
IL
T
E R
E L E
C T
R
IC
H E
A T
P R
E F
IL
T
E R
E X
H A
U S
T F
A N
ROOF TOP AIR HANDLING UNIT SCHEDULE
ROOF TOP AIR HANDLING UNITS RTU-1 & RTU-2 ACOUSTICS IN DECIBELS PER OCTAVE BAND
SPLIT SYSTEM AIR HANDLING UNITS (DUCTLESS)
REFER TO AIR TO AIR PLATE FRAME HEAT EXHANGER SCHEDULE THIS SHEET
REMARKS:
SERVES
WATER PRESSURE DROP (FT WG)
AIR PRESSURE (IN WG)
GPM
WHEEL DIAMETER
FILTER PRESSURE DROP (IN WG)
FILTER AREA (SQUARE FEET)
FILTER MINIMUM EFFICIENCY
FILTER TYPE
REMARKS:
TYPE UNIT
LOCATION
SYSTEM NO.
VFD
REMARKS:
TYPE FAN
REMARKS:
REMARKS:
VSD
REMARKS:
TYPE FAN
SOUND ATTENUATOR
SQ. FT. FACE AREA MIN.
FACE VELOCITY MAX. (fpm)
PREFILTER MIN. EFF.
PREFILTER TYPE
PREFILTER AREA - SQ FT.
FINAL FILTER MIN. EFF.
FINAL FILTER TYPE
FINAL FILTER SIZE & NO.
ACCESS SECTION WITH ACCESS DOOR
SUPPORT BASE
VIBRATION ISOLATORS ON ALL FANS
MOTOR OPER. SMOKE DAMPERS
DISCHARGE AIR PLENUM W/ ACCESS DOOR
RETURN AIR PLENUM W/ ACCESS DOOR
MIXING SECTION WITH ACCESS DOOR
SENSIBLE LOAD (MBH)
EAT Db/Wb (°F)
LAT Db/Wb (°F)
FINS PER FOOT MAX.
SQ. FT. FACE AREA MIN.
FACE VELOCITY MAX.
EWT °F
KW TOTAL LOAD
LAT Db °F
EAT Db °F
TYPE
TOTAL CFM
ROWS MIN.
TYPE COIL
WHEEL DIAMETER MIN. (in.)
RPM APPROX.
TYPE DRIVE
HP MIN/VOLT/PH/HZ
CLASS FAN
ARRANGEMENT
RPM APPROX.
HP MIN/VOLT/PH/HZ
TYPE DRIVE
EXTERNAL STATIC PRESSURE
TOTAL CFM (CFM PER FAN)
TOTAL LOAD (MBH)
ARRANGEMENT
CLASS FAN
TOTAL CFM
TOTAL CFM (CFM PER FAN)
EXTERNAL STATIC PRESSURE (IN WG)
SYSTEM TYPE
AIR PRESSURE (IN WG)
ECONOMIZER
OUTSIDE AIR CFM (MINIMUM/ECONOMIZER)
LWT °F
REMARKS:
SOUND PATH
SUPPLY FAN
BOTTOM
RETURN AIR PATH
63 HZ 125 250 500 1K 2K 4K 8K
74 DB 80 DB 73 DB 55 DB 48 DB 51 DB 56 DB 55 DB
78 DB 75 DB 88 DB 74 DB 71 DB 72 DB 67 DB 60 DB
AIR TO AIR PLATE FRAME HEAT EXCHANGER SCHEDULE
AIR
HANDLING
UNIT
LOCATION
VENTILATION/
EXHAUST AIR
FLOWS CFM
OUTSIDE AIR DELIVERED /SUPPLY AIR EXHAUST AIR OUT
SUMMER
TEMP (Db)
SUMMER
Wb
WINTER
TEMP
(Db)
WINTER
Wb
CFM
PRESSURE
DROP IN.
WG
SUMMER
TEMP
(Db)
SUMMER
TEMP
(Wb)
WINTER
TEMP
(Db)
WINTER
TEMP
(Wb)
CFM
STATIC
PRESSURE
SUMMER
TEMP
(Db)
SUMMER
TEMP
(Wb)
WINTER
TEMP
(Db)
WINTER
TEMP
(Wb)
RTU-1 ROOF 1660
99 74 15 12
1660 0.710 82.9 69.4 55.4 37.9 1420 0.864 93.8 69.1 29.9 29.6
RTU-2 ROOF 1660 1660 0.710 82.9 69.4 55.4 37.9 1420 0.864 93.8 69.1 29.6 29.6
20/460/3Ø/60
2 @ 10/460/3Ø/60
FAN SIZED FOR
ECONOMIZER
SCR STAGING SCR STAGING
460V/3⌀/60HZ 460V/3⌀/60HZ
MOCP MCA MOCP MCA
70.00 A
125.00 A
50.15 A
115.90 A
70.00 A
125.00 A
50.15 A
115.90 A
E L E
C T
R
IC
A
L VOLTAGE/PHASE/HZ
CONNECTION #1
CONNECTION #2
PROVIDE ONE
ADDITONAL TO OWNER.
PROVIDE ONE
ADDITONAL TO OWNER.
PROVIDE ADDITIONAL SET OF
FILTERS TO OWNER.
NONE NONE
NONE NONE
NONE NONE
3.63 3.63TOTAL STATIC PRESSURE
8.47 8.47TOTAL STATIC PRESSURE (IN WG)
PROVIDE ADDITIONAL SET OF
FILTERS TO OWNER.
SUMMER SENSIBLE EFF.
ENERGY
RECOVERED
78.2% 29.0 MBH
DRY DESIGN
78.2%
78.2% 78.2%
WINTER SENSIBLE EFF.
ENERGY
RECOVERED
78.6% 72.4 MBH
DRY DESIGN
82.8%
78.6% 82.8%29.0 MBH 72.4 MBH
ROOF CURB: YES YES
LEAVING
RH
50.95%
50.95%
LEAVING
RH
9.33%
9.33%
LEAVING
RH
28.24%
28.24%
LEAVING
RH
96.59%
96.59%
AIR COOLED CHILLER ACOUSTICAL PERFORMANCE SCHEDULE
SOUND PATH 63 HZ 125 250 500 1K 2K 4K 8K
67 DB 66 DB 62 DB 63 DB 59 DB 57 DB 53 DB 48 DB
SOUND PRESSURE LEVELS AT 30 FEET.
NOTES:
1. SOUND PRESSURE LEVELS DERIVED FROM AHRI 370 SOUND POWER USING HEMISPHERE METHOD.
COOLING COIL PIPING ENCLOSURE YES YES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/9
/2
:1
:5
P
M
M003
MECHANICAL - SCHEDULES
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
08/18/2022 GAT CAC
GENERAL NOTES
1. COIL AND BOX SIZE MAY BE INCREASED TO MEET REQUIRED CONDITIONS; BUT SHALL NOT BE DECREASED FROM SIZE SHOWN.
2. BOXES SHALL BE SET FOR MAXUMUM CFM SHOWN ON PLANS.
3. DUCT CONNECTIONS TO BOXES SHALL BE SAME SIZE AS BOX INLET UNLESS SHOWN OTHERWISE.
4. VARIABLE VOLUME BOXES SHALL OPERATE DOWN TO 50% OF MAXIMUM FLOW.
5. CONTROLS SHALL BE DDC PROVIDED BY CONTROLS CONTRACTOR AND INSTALLED BY BOX MANUFACTURER.
6. MAXIMUM NC LEVEL OF 30 ON ALL BOXES. PROVIDE SOUND ATTUNUATOR AS REQUIRED.
7. PROVIDE DIFFERENTIAL AIRFLOW SWITCH.
ELECTRIC TERMINAL UNIT SCHEDULE
Terminal No. Airflow Min. CFM Reheat CFM Unit Size E.A.T. (°F) Heating L.A.T.
(°F) EC Capacity
(kW) Steps Volts MOP MCA
1-1-1V 620 CFM 310 CFM 310 CFM 10 55 95.61 4.0 SCR 277/1 20 18.05
1-1-2V 1400 CFM 700 CFM 700 CFM 12 55 90.97 8.0 SCR 480/1 25 20.83
1-1-3V 460 CFM 230 CFM 230 CFM 8 55 96.05 3.0 SCR 277/1 15 13.54
1-1-4V 530 CFM 265 CFM 265 CFM 8 55 90.63 3.0 SCR 277/1 15 13.54
1-1-5V 400 CFM 200 CFM 200 CFM 8 55 94.34 2.5 SCR 277/1 15 11.28
1-1-6V 470 CFM 235 CFM 235 CFM 8 55 96.05 3.0 SCR 277/1 15 13.54
1-1-7V 840 CFM 420 CFM 310 CFM 10 55 93.47 5.5 SCR 277/1 15 14.32
1-1-8V 560 CFM 280 CFM 280 CFM 10 55 93.65 3.5 SCR 277/1 20 15.79
1-1-9V 600 CFM 300 CFM 300 CFM 8 55 91.72 3.5 SCR 277/1 20 15.79
1-1-10V 220 CFM 110 CFM 110 CFM 6 55 90.00 1.0 SCR 277/1 15 4.51
1-1-11V 670 CFM 335 CFM 335 CFM 10 55 92.58 4.0 SCR 480/1 15 10.42
1-1-12V 250 CFM 125 CFM 125 CFM 6 55 92.77 1.5 SCR 277/1 15 6.77
1-1-13V 130 CFM 70 CFM 70 CFM 6 55 91.32 1.5 SCR 277/1 15 6.77
1-1-14V 360 CFM 180 CFM 180 CFM 8 55 90.00 2.0 SCR 277/1 15 13.54
1-1-15V 190 CFM 175 CFM 175 CFM 6 55 98.10 2.5 SCR 277/1 15 11.3
1-2-1V 800 CFM 400 CFM 400 CFM 10 55 90.41 4.5 SCR 480/1 15 11.72
1-2-2V 630 CFM 315 CFM 315 CFM 10 55 94.97 4.0 SCR 277/1 20 18.05
1-2-3V 190 CFM 95 CFM 95 CFM 6 55 90.00 1.0 SCR 277/1 15 4.51
1-2-4V 360 CFM 180 CFM 180 CFM 8 55 90.00 2.0 SCR 277/1 15 9.03
1-2-5V 420 CFM 210 CFM 210 CFM 8 55 99.50 3.0 SCR 277/1 15 13.54
1-2-6V 420 CFM 210 CFM 210 CFM 8 55 92.47 2.5 SCR 277/1 15 11.28
1-2-7V 570 CFM 285 CFM 285 CFM 8 55 93.65 3.5 SCR 277/1 20 15.79
1-2-8V 380 CFM 190 CFM 190 CFM 8 55 94.34 2.5 SCR 277/1 15 11.28
1-2-9V 250 CFM 125 CFM 130 CFM 6 55 91.32 1.5 SCR 277/1 15 6.77
1-2-10V 380 CFM 190 CFM 190 CFM 8 55 94.34 2.5 SCR 277/1 15 11.28
1-2-11V 400 CFM 200 CFM 200 CFM 8 55 94.34 2.5 SCR 277/1 15 11.28
1-2-12V 680 CFM 340 CFM 340 CFM 10 55 92.58 4.0 SCR 480/1 15 11.72
1-2-13V 630 CFM 315 CFM 315 CFM 10 55 94.97 4.0 SCR 277/1 20 18.05
1-2-14V 210 CFM 105 CFM 105 CFM 6 55 90.00 1.0 SCR 277/1 15 4.51
1-2-15V 500 CFM 250 CFM 250 CFM 8 55 92.77 3.0 SCR 277/1 15 13.54
1-2-16V 160 CFM 80 CFM 80 CFM 6 55 90.00 1.5 SCR 277/1 15 6.77
1-2-17V 325 CFM 300 CFM 300 CFM 8 55 98.70 4.0 SCR 277/1 20 18.1
1-2-18V 420 CFM 210 CFM 210 CFM 8 55 92.47 2.5 SCR 277/1 15 13.54
Revisions: Date:
CFM
A
CFM
B
CFM
C
CFM
D
CFM
E
CFM
F
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
CFM
LOUVERED SUPPLY DIFFUSER
SIDEWALL EXHAUST REGISTER
PERFORATED EXHAUST REGISTERS
PERFORATED RETURN REGISTERS
SIDEWALL RETURN REGISTER
SIDEWALL SUPPLY REGISTER
AIR COOLED WATER CHILLER SCHEDULE
UNIT NO.
TOTAL
COOLING
CAPACITY
(TONS)
ENTERING
WATER
TEMPERATURE
(°F)
LEAVING
WATER
TEMPERATURE
(°F)
WATER
FLOWRATE
(GPM)
MAX. WATER
PRESS. DROP
(EVAPORATOR)
(FT. WG)
OUTSIDE AIR
TEMP (°F)
ELECTRICAL DATA COMPRESSOR
IPLV.IP
MCA
VOLTAGE
(V/PH/HZ)
TYPE QUANTITY
CH-1 70 56 42 113 8.42 95 147.8 460/3/60 SCROLL 4 14.71
SYMBOL TYPICAL MODULE SIZE - 24"x24"
136-210 CFM 9"x9" FACE 8" NECK
0-135 CFM 6"x6" FACE 6"∅ NECK
211-325 CFM 12"x12" FACE 10" NECK
326-475 CFM 12"x12" FACE 12" NECK
476-650 CFM 15"x15" FACE 14" NECK
CFM
CFM
CFM
CFM
CFM
CFM
CFM
650-840 CFM 18"x18" FACE 16" NECK
841-1125 CFM 18"X18" FACE & NECK
NOTES:
1. ALL AIR TERMINALS SHALL BE ALUMINUM CONSTRUCTION.
ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
2. DIFFUSERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE
MOUNTED FRAMES.
3. PROVIDE SR MODEL ROUND NECK ADAPTER.
CFM RANGE, FACE SIZE, & NECK SIZE
CFM
0-120 CFM 6"X6" FACE 6" NECK
CFM
121-240 CFM 9"X9" FACE 8" NECK
12"x12" REGISTER
12"x12" REGISTER
SYMBOL SIZE
111-250 CFM 10"x6"
0-110 CFM 8"x4"
251-480 CFM 14"x8"
481-650 CFM 18"x10"
651-835 CFM 18"x12"
836-1400 CFM 24"x18"
ALL AIR TERMINALS SHALL BE ALUMINUM CONSTRUCTION.
SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
SYMBOL REGISTER SIZE 24"x24"
136-210 CFM 8" ROUND NECK
0-135 CFM 6" ROUND NECK
211-325 CFM 10" ROUND NECK
326-475 CFM 12" ROUND NECK
651-840 CFM 16" ROUND NECK
841-2000 CFM 22"x22" NECK
476-650 CFM 14" ROUND NECK
CFM
A
CFM
B
CFM
C
CFM
D
CFM
E
CFM
F
CFM
G
NOTES:
1. ALL AIR TERMINALS SHALL BE ALUMINUM CONSTRUCTION.
ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
2. REGISTERS LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE
MOUNTED FRAMES.
SYMBOL REGISTER SIZE 24"x24"
136-210 CFM 8" ROUND NECK
0-135 CFM 6" ROUND NECK
211-325 CFM 10" ROUND NECK
326-475 CFM 12" ROUND NECK
651-840 CFM 16" ROUND NECK
841-2000 CFM 22"x22" NECK
476-650 CFM 14" ROUND NECK
CFM
CFM
CFM
CFM
CFM
CFM
CFM
NOTES:
1. ALL AIR TERMINALS SHALL BE ALUMINUN CONSTRUCTION.
ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
2. GRILLES LOCATED IN HARD CEILING AREAS SHALL BE PROVIDED WITH SURFACE
MOUNTED FRAMES.
12"x12" REGISTER
CFM
H
0-135 CFM 6"∅ NECK
CFM
CFM
CFM
0-120 CFM 6" NECK
12"x12" REGISTER
0-130 CFM 6" NECK
16"x16" REGISTER
131-240 CFM 8" NECK
16"x16" REGISTER
SYMBOL SIZE
111-250 CFM 10"x8"
0-110 CFM 8"x4"
251-480 CFM 14"x10"
481-650 CFM 18"x12"
651-835 CFM 20"x14"
836-1400 CFM 24"x18"
ALL AIR TERMINALS SHALL BE ALUMINUM CONSTRUCTION.
SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
226-450 CFM 12"x10"
0-225 CFM 10"x6"
451-700 CFM 18"x12"
701-900 CFM 24"x12"
901-1180 CFM 30"x12"
1181-1350 CFM 36"x12"
SYMBOL CFM RANGE & MODULE SIZE
ALL AIR TERMINALS SHALL BE ALUMINUM CONSTRUCTION.
SEE ARCHITECTURAL CEILING PLAN FOR PROPER FRAME STYLE.
DOUBLE DEFLECTION
TYPE
ELECTRIC UNIT HEATER SCHEDULE
MARK
MODEL
NUMBER
CAPACITY
BTU
CAPACITY
WATTS
VOLTAGE AMPS DIMENSIONS
EH-1 400C61 5,120 1,500 120 1.6 - 12.5 18"x12"x3.5"
EH-2 400C61 5,120 1,500 120 1.6 - 12.5 18"x12"x3.5"
1. INTEGRAL THERMOSTAT SHALL BE LOCATED IN JUNCTION BOX WITH ADJUSTMENT KNOB
FOR TAMPER PROOF OPERATION.
2. DISCONNECT SWITCH SHALL BE MOUNTED IN JUNCTION BOX.
3. DISCONNECT SWITCH PROVIDED BY MECHANICAL CONTRACTOR.
4. UNIT SHALL BE RECESSED WALL MOUNTED.
NOTES
CHILLED WATER PACKAGED PUMPING SYSTEMS SCHEDULE
TAG
PUMP
TAG
MIN
SUCT
MIN
DISCH SERVICE GPM FT.
PPS-1
CHWP-1 2.0 1.5 CHW 113.0 78.0 5.0 1750 460/3/60 PREMIUM
NOTES:
1. EACH PUMP SIZED FOR 100% OF SYSTEM DEMAND.
2. MAXIMUM PACKAGE DIMENSIONS SHALL NOT EXCEED 102"W x 120"L x 131"H.
3. SYSTEM CONNECTIONS SHALL BE 4".
4. TOTAL PACKAGE PRESSURE DROP SHALL NOT EXCEED 10.5 FEET (Cv = 47.9).
5. REFER TO PACKAGED PUMPING SYSTEM SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
6. FURNISH HYDRONIC INDICATOR ON PACKAGE WITH EACH PUMP.
7. PROVIDE ENCLOSURE. REFER TO 2/M003A.
8. INSULATION FOR BUFFER TANK SHALL BE 2" THICK MINIMUM, FLEXIBLE ELASTOMERIC CELLULAR. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. INSULATE
CHILLED WATER PIPING AND EQUIPMENT INSIDE CHILLED WATER PIPING SYSTEM ENCLOSURE WITH FLEXIBLE ELASTOMERIC CELLULAR INSULATION BASED ON
INSULATION SPECIFICATIONS REQUIREMENT.
9. SOFT START VFD.
10. EXHAUST WALL MOUNTED FAN 500 CFM; 0.5" SP, 1/4HP, 120V/60HZ WITH EXTERIOR SWITCH. PROVIDE ELECTRICAL TRANSFORMER IF REQUIRED.
11. ELECTRIC HEATER 4.0KW, 120 OR 240V. PROVIDE ELECTRICAL TRANSFORMER IF REQUIRED. HEATER CONTROLLED BY WALL MOUNTED THERMOSTAT.
12. WALL MOUNTED LOUVER 18”X18” WITH GRAVITY DAMPER.
13. PUMPS SHALL BE INSTALLED WITH NEOPRENE PADS FLOOR MOUNTED. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
14. PROVIDE 3/4" CONDENSATE DRAIN AT THE PUMPS. EXTEND PIPE ON ROOF TO THE GUTTERS.
15. CHILLED WATER PUMPING SYSTEM TO BE PROVIDE AS A SINGLE PACKAGE AND INDIVIDUAL COMPONENTS ARE NOT TO BE FIELD INSTALLED.
16. SINGLE POINT POWER PANEL TO BE HARD WIRED BY EC.
17. SEE DETAIL BELOW FOR ADDITIONAL EQUIPMENT INFORMATION.
18. PROVIDE AND INSTALL ROOF CURB SUPPORT FOR ENCLOSURE.
19. PROVIDE PIPE TRANSITIONS FOR ALL 2" AND 3" CONNECTIONS.
CHWP-2
ODP VFD 2" / 85 3"x2" 500
GALLON
8 GALLON
HP RPM V/PH/HZ EFF TYPE
MOTOR
CONTROL
TRIPLE DUTY
VALVE / MIN Cv
SUCTION
DIFFUSER
BUFFER
TANK
EXPANSION
TANK
MOTORS
MAJOR HYDRONIC COMPONENT MODEL NUMBERSPUMPS
2.0 1.5 CHW 113.0 78.0 1750 460/3/60 PREMIUM ODP VFD5.0
NOTES:
1. STARTER / DISCONNECT.
2. R410A REFRIGERANT.
3. PROVIDE WITH FACTORY INSTALLED CONTROLS.
4. UNIT MANUFACTURER SHALL INSTALL ACOUSTICAL INSULATION ON ALL COMPRESSORS. INSTALL AT LEAST 1" CLOSED CELL WRAP.
5. CONDENSER FANS SHALL BE CORROSION RESISTANT GLASS FIBER REINFORCED COMPOSITE BLADES MODLED INTO LOW NOISE PERFORMANCE.
6. UNIT SHALL HAVE LOW AMBIENT HEAD PRESSURE CONTROL.
7. CHILLER SHALL BE ABLE TO MODULATE IT'S CAPACITY FROM 100% DOWN TO 25% MINIMUM OR LOWER WITHOUT SACRIFICING EFFICIENCY OF PERFORMANCE.
8. UNIT SHALL BE MANUFACTURED WITH SECURITY GRILLES/HAIL GUARDS.
MOCP
175.0
DOUBLE DEFLECTION
DOUBLE DEFLECTION
DOUBLE DEFLECTION
DOUBLE DEFLECTION
DOUBLE DEFLECTION
NPLV
14.37
3"x2"2" / 85
CHILLED WATER PUMPING SYSTEM (PPS-1) 1CHILLED WATER PUMPING SYSTEM (PPS-1) ENCLOSURE 2
NTS NTS
PARTS LIST
ITEM QTY DESCRIPTION
5HP 1800 RPM END SUCTION
PUMP
3" X 2" FLANGED SUCTION
DIFFUSER
2" FLANGED TRIPLE DUTY
VALVE
500 GALLON, 3" FLANGE
CONN. CHILLED WATER
BUFFER TANK
8 GALLON VERTICAL
EXPANSION.
16 460V/3⌀ SINGLE POINT
POWER PANEL WILL THE
FOLLOWING ELECTRICAL
CHARACTERISTICS:
FLA: 31
MCA:33
MOCP: 40
MAKE-UP AIR WALL LOUVER
WITH HOOD.
4 KW UNIT HEATER.19
500 CFM 0.5HP WALL
MOUNTED EXHAUST FAN
NOTES:
1. ALL ENCLOSURE DIMENSIONS
ARE SUBJECT TO CHANGED BASED
ON MANUFACTURER.
2. SEE CHWP SCHEDULE FOR MORE
DETAILS.
NEMA COMBINATION
STARTER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/9
/2
:1
:5
P
M
M003A
MECHANICAL - SCHEDULES
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
08/18/2022 GAT CAC
NOTES:
1. PROVIDE FIBERGLASS ENCLOSURE. BASIS OF
DESIGN "VPC FIBERGLASS MODEL VPC-B8X10. PRE
ENGINEERED INSULATED FRP WITH DIMENSIONS OF
120"L X 96"W X 104"H.
2. ENCLOSURE SHALL WITHSTAND 125 MPH WIND AND
30 PSF OF SNOW.
3. ENCLOSURE SHALL HAVE 36"X80" DOOR WITH
STAINLESS STEEL HINGES WITH 3-POINT LATCH.
MECHANICAL - CHILLED WATER PIPING SCHEMATIC
NTS
M004
CHILLER
CH-1
TI PI
TI PI FS
EXTEND TO
THE GUTTER
1"
4" CHWS
4" CHWR
TI PI
PI
CHWP-1 (VFD)
SUCTION DIFFUSER
W/ STRAINER
TI PI
PI
CHWP-2 (VFD)
SUCTION DIFFUSER
W/ STRAINER
4" CHWR
CHECK
VALVE
CHECK
VALVE
4" CHWR
BUFFER
TANK
EXPANSION
TANK
PRESSURE
REDUCING
VALVE
UNION
(TYPICAL)
CHECK
VALVE
(TYPICAL)
STRAINER
(TYPICAL)
BALL
VALVE
(TYPICAL)
4" CHWR
RTU-1 RTU-2
.5
C
H W
R
.5
C
H W
S
.5
C
H W
R
.5
C
H W
S
2.5"CHWS
2.5"CHWR
3 WAY CONTROL
VALVE (TYPICAL)
4" CHWR
GENERAL NOTES:
1. CHILLED WATER PUMPING PACKAGE SHALL BE PROVIDED BY MANUFACTURER AS COMPLETE
STAND ALONE PACKAGE TOTALLY ASSEMBLED AT THE FACTORY AND READY FOR INSTALLATION
BY CONTRACTOR .
A. COMPLETE ASSEMBLY SHALL BE MOUNTED ON A COMMON BASE AND AS A MINIMUM
INCLUDE, DUAL SET OF PUMPS WITH VFDs, EXPANSION TANK, BUFFER TAHNK, ALL
REQUIRED ELECTRICAL, HYDRONIC SPECIALTIES, COMPONENTS AND CONTROLS FOR
STAND ALONE OPERATIONS.
B. REFER TO SPECIFICATIONS FOR COMPLETE DESCRIPTION OF REQUIREMENTS.
2. CONTRACTOR SHALL PROVIDE AND INSTALL PIPING, SUPPORTS AND HYDRONIC SPECIALTIES NOT
PROVIDED WITH PUMPING PACKAGE INCLUDING ISOLATION VALVES, VIBRATION ISOLATORS,
BYPASS VALVES, ETC. INSTALLATION SHALL BE IN COMPLIANCE WITH DESIGN DOCUMENTS AND
MANUFACTURER AND INSTALLATION MANUALS.
3. ALL EXPOSED CHILLED WATER PIPING OUTSIDE OF THE BUILDING SHALL HAVE ELECTRICAL HEAT
TRACE FURNISHED WITH ALL NECESSARY CONTROLS AS REQUIRED BY MANUFACTURER.
CHILLED WATER
PUMPING PACKAGE
SCALE:
WATER BACKFLOW PREVENTER
(BY OTHERS)
1"
FLOW
METER
LEGEND
FS
T1
P1
M
WATER FLOW SWITCH
THERMOMETER IN PIPING WELL
PRESSURE GAUGE IN PIPING WELL
BALL VALVE
GATE VALVE
WATER FLOW BALANCING VALVE
MOTORIZED ISOLATION VALVE (2 WAY)
4" CHWS
CHEMICAL
SHOT FEEDER
4" VALVE WITH
BLIND FLANGE
2" VALVE FOR
QUICK FILL
4" CHWS
CONTROL VALVE (3 WAY)
UNION
CHECK VALVE
STRAINER
4" VALVE W/
BLIND FLANGE
MAKEUP WATER
PIPING SHOWN ON
MH200 AND PLUMBING
PLANS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/9
/2
:1
:5
P
M
M004
MECHANICAL - WATER FLOW
DIAGRAMSCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
CONDENSING UNIT
REFRIGERANT
COOLING COIL
D
X
RETURN AIR
FILTER
SUPPLY FAN SPLIT SYSTEM AIR HANDLING UNIT CONTROL (TYPICAL)
SPACE TEMPERATURE CONTROL: THE SPACE TEMPERATURE CONTROLLED LOCALLY. A DDC TEMPERATURE
SENSOR SHALL BE PROVIDED. THIS TEMPERATURE SENSOR SHALL REPORT THE SPACE TEMPERATURE TO THE ECC.
ALARMS: ALARM IF SPACE TEMPERATURE REPORTED BY THE DDC TEMPERATURE SENSOR REPORTS A TEMPERATURE
ABOVE 80 DEGREES FAHRENHEIT.
PROVIDE DDC TEMP SENSOR LOCATED IN COMM ROOM
TT
T-1
BI-1
HIGH TEMPERATURE
AI-1
SPACE TEMPERATURE
DUCTLESS SPLIT SYSTEM DIAGRAM
N.T.S.
CHILLER AND PUMPS CONTROL:
A. CHILLED WATER SYSTEM WILL CONSIST OF ONE AIR-COOLED, CHILLER
AND DUAL PUMP PACKAGED PUMPING SYSTEM.
6. NORMAL OPERATION' MODES:
A. NORMAL DAMPER D-6 POSITIONING, WITH MINIMUM OUTSIDE AIR. WHEN THE AIR SYSTEM IS OPERATING WITH THE 'OUTSIDE AIR
ECONOMIZER' MODE DISABLED, THE SYSTEM SHALL OPERATE WITH THE REQUIRED MINIMUM VENTILATION (OUTSIDE) AIR, AND
THE SYSTEM DAMPERS SHALL BE POSITIONED AS FOLLOWS:
(1) THE OUTSIDE AIR DAMPER D-6 BE OPENED TO ITS MINIMUM OUTSIDE AIR POSITION. THE POSITION SHALL BE DETERMINED
BY THE TEST AND BALANCE CONTRACTOR.
(2) D-4 RETURN AIR DAMPER AS WELL AS SUPPLY AIR DAMPER D-7 SHALL BE IN THEIR FULL-OPEN POSITIONS.
(3) THE EXHAUST AIR DAMPERS D-1 AND D-5 SHALL BE OPEN TO OPERATE IN NORMAL VENTILATION POSITIONS (NOT ECONOMIZER).
B. OUTSIDE AIR ECONOMIZER' COOLING MODE OPERATIONS:
(1) TEMPERATURE AND HUMIDITY SENSORS SHALL BE INSTALLED IN THE OUTSIDE AIR STREAM AND IN THE RETURN AIR DUCT OF
THIS RTU. THE DDC SYSTEM SHALL USE THESE SENSORS TO CALCULATE THE ENTHALPIES OF THE RESPECTIVE
AIRSTREAMS.
(2) COMPARATIVE ENTHALPY SHALL BE USED TO AS THE BASIS FOR SWITCHING THE SYSTEM TO OPERATE IN THE 'OUTSIDE AIR
ECONOMIZER' MODE.' WHEN THE CALCULATED ENTHALPY IN THE OUTSIDE AIR IS LESS THAN THE CALCULATED ENTHALPY IN THE
RETURN AIR STREAM, THE `OUTSIDE AIR ECONOMIZER' MODE SHALL BE ENABLED.
(3) DURING THE 'OUTSIDE AIR ECONOMIZER' MODE THE OUTSIDE AIR AND BOTH EXHAUST AIR DAMPERS D-1 AND D-5 SHALL BE
MODULATED AND CONTROLLED BY THE RTU DISCHARGE AIR TEMPERATURE SENSOR THROUGH
THE DDC SYSTEM. RETURN AIR DAMPERS D-2 AND D-4 SHALL MODULATE OPEN .
(4) THE ECONOMIZER DAMPERS SHALL HAVE THE FOLLOWING OPERATION POSITIONING: OUTSIDE AIR DAMPER D-6
SHALL BE NORMALLY-CLOSED AND EXHAUST DAMPERS D-1 AND D-5 OPEN.
(5) DURING THE 'OUTSIDE AIR ECONOMIZER' MODE A SENSOR IN THE MIXED AIR PLENUM SHALL ACT, THROUGH THE DDC SYSTEM, AS A MODULATING LOW LIMIT (SET AT 50 DEGREES, F.) TO KEEP THE MIXED AIR TEMPERATURE FROM FALLING TOO LOW.
(6) THE 'OUTSIDE AIR ECONOMIZER' MODE SHALL CONTINUE UNTIL THE UNIT IS SHUTDOWN BY THE DDC SYSTEM, OR UNTIL THE
ENTHALPY IN THE OUTSIDE AIR IS HIGHER THAN THE ENTHALPY IN THE RETURN AIR STREAM. WHEN THE 'OUTSIDE AIR
ECONOMIZER' MODE IS DISABLED, THE OUTSIDE AIR DAMPER D-6 AND EXHAUST DAMPERS D-1 AND D-5 SHALL BE
RETURNED TO THEIR NORMAL VENTILATION POSITIONS.
C. SUPPLY AIR TEMPERATURE CONTROLS:
(1) THE RTU DISCHARGE AIR TEMPERATURE CONTROLLER SHALL CONTROL THE OPERATIONS OF THE
RTU DAMPERS (WHEN THE OUTSIDE AIR ECONOMIZER' MODE IS ENABLED, AS PREVIOUSLY DESCRIBED), THE CHILLED WATER
COOLING COIL AND THE ELECTRIC HEAT. UPON A RISE IN DISCHARGE AIR TEMPERATURE ABOVE THE SETPOINT 55°F, THE DDC SYSTEM
SHALL ACT TO MODULATE RTU DAMPERS AS DESCRIBED ABOVE TO PROVIDE
COOLER AIR TO REDUCE THE DISCHARGE AIR TEMPERATURE. UPON A FALL IN DISCHARGE AIR TEMPERATURE BELOW THE
SETPOINT, THE SYSTEM'S DDC SHALL ACT TO MODULATE THE DAMPERS TO INCREASE THE DISCHARGE AIR TEMPERATURE.
THE HEATING AIR COIL CONTROLLER SHALL BE MODULATD FROM DISCHARGE AIR T-RA SENSOR THROUGH RTU DDC CONTROLS.
DISCHARGE SENSOR SHALL ACT AS A MODULATING LOW LIMIT SWITCH SUCH THAT THE HEAT COILS DISCHARGE AIR SHALL BE MAINTAINED AT 50°F MINIMUM DURING HEATING OPERATIONS. SET POINT SHALL BE ADJUSTABLE
(2) WHEN THE OUTSIDE AIR TEMPERATURE IS ABOVE 50 DEGREES, F., THE HEATING SHUTOFF.
(3) COOLING COIL OPERATION SHALL BE CONTROLLED WITH A 3-WAY CONTROL VALVE. 42 DEGREES F COOLED
CHILLED WATER SHALL BE PROVIDED BY A REMOTE AIR-COOLED CHILLER, USING DUAL PUMP PUMPING
PACKAGE SYSTEM.
(4) WHEN THE DISCHARGE AIR TEMPERATURE SENSOR, THRU THE DDC, IS CALLING FOR COOLING, AND THE `OUTSIDE AIR
ECONOMIZER' MODE IS DISABLED, THE DDC SYSTEM SHALL SEND A SIGNAL TO START THE PRIMARY CHILLED WATER PUMP AND
THE CHILLER. THE DDC WILL ALSO MODULATE THE 3-WAY CONTROL VALVE TO SEND CHILLED WATER FLOW
THROUGH THE COOLING COIL.
(5) WHEN THE DISCHARGE AIR TEMPERATURE FALLS, THE DDC SYSTEM SHALL ACT TO MODULATE THE 3-WAY CONTROL VALVE TO
REDUCE THE FLOW OF CHILLED WATER THROUGH THE COOLING COIL.
(6) WHEN THE OUTSIDE AIR TEMPERATURE IS BELOW 40 DEGREES, F., ADJUSTABLE, THE CHILLER AND PUMPS SHALL BE DISABLED.
THE POSITION SHALL BE DETERMINED BY THE TEST AND BALANCE CONTRACTOR.
(4) D-2 DAMPER SHALL BE IN CLOSED POSITION.
THE DYNAMIC DUCT STATIC PRESSURE CONTROL SETPOINT SHALL BE CONTINUOUSLY MONITORED AND THE SETPOINT SHALL
BE ADJUSTED TO KEEP AT LEAST ONE AIR TERMINAL UNIT VAV BOX DAMPER AT 95 PERCENT OPEN, MINIMUM.
THE AIRFLOW THROUGH THE SUPPLY AIR FANS SHALL BE CONTINUOUSLY READ AND SENT TO THE DDC SYSTEM AND
OPERATOR'S WORKSTATION. AIRFLOW THROUGH THE EXHAUST AIR FANS SHALL BE CONTINUOUSLY READ AND
SENT TO THE DDC SYSTEM AND THE OPERATOR'S WORKSTATION.
PROVIDE A SYSTEM SWITCH, AT THE BAS, TO ALLOW FOR MANUAL OVERRIDE SHUTDOWN OF THE UN-OCCUPIED PERIOD
OPERATIONS.
DUCTWORK SMOKE DETECTOR
TEMPERATURE SENSOR - SUPPLY AIR
TEMPERATURE SENSOR - OUTSIDE AIR
TEMPERATURE SENSOR - MIXED AIR
TEMPERATURE SENSOR - HEATING COIL
TEMPERATURE SENSOR - LOW LIMIT (AVERAGING)
RELATIVE HUMIDITY SENSOR - SUPPLY AIR
RELATIVE HUMIDITY SENSOR - OUTSIDE AIR
RELATIVE HUMIDITY SENSOR - MIXED AIR
RELATIVE HUMIDITY SENSOR - RETURN AIR
TEMPERATURE SENSOR - RETURN AIR
DAMPER AND #
VARIABLE FREQUENCY DRIVE - SUPPLY FAN
PRESSURE DIFFERENTIAL - FINAL FILTER
PRESSURE DIFFERENTIAL - PRE-FILTER
STATIC PRESSURE
HIGH STATIC LIMIT
ANALOG INPUTAI
ANALOG OUTPUTAO
BINARY INPUTBI
BINARY OUTPUT
HVAC CONTROLS LEGEND
TEMPERATURE SENSOR - COOLING COIL
VARIABLE FREQUENCY DRIVE - EXHAUST FAN
SWITCH - ON/OFF
HEAT EXCHANGER BY-PASS DAMPER
AIR FLOW MONITORING STATION
RELATIVE HUMIDITY EXHAUST SENSOR
SMOKE DETECTOR - EXHAUST AIR
VARIABLE FREQUENCY DRIVE - CHILLED WATER PUMP
EMERGENCY STOP SWITCH
TEMPERATURE SENSOR
ENGINEERING CONTROL CENTER
SEQUENCE OF OPERATION
EXHAUST AIR
OUTSIDE AIR SUPPLY
DDC CONTROLLER PANEL
TO FIRE
ALARM
SYSTEM
ESS
RETURN AIR
EXHAUST AIREXHAUST AIR
SD
TO FIRE ALARM
SYSTEM
THE CONTROL OF PRESSURE INDEPENDENT VAV BOXES WITH ELECTRIC REHEAT AT
THE VAV TERMINAL SHALL BE AS FOLLOWS:
THE CONTROLLER SHALL MODULATE THE SUPPLY AIR DAMPER AND ELECTRIC REHEAT
IN SEQUENCE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE SETPOINT.
THE SUPPLY AIR DAMPER SHALL BE SET TO MINIMUM WHEN THE ROOM
TEMPERATURE IS BELOW THE COOLING SETPOINT 75°F. THE REHEAT SHALL NOT
TURN ON UNTIL THE ROOM TEMPERATURE HAS DROPPED BELOW THE HEATING
SETPOINT 70°F. THE ROOM TEMPERATURE SETPOINT MAY BE ADJUSTED BY THE
OCCUPANT, WITHIN PRESELECTED LIMITS, BY CHANGING A SETPOINT ADJUSTMENT
ON THE ROOM THERMOSTAT, OR A SETPOINT MAY BE SELECTED BY THE DDC
SYSTEM OPERATOR THAT WILL OVERRIDE AND LIMIT ANY CHANGES MADE AT THE
ROOM STATUS.
THE ROOM TEMPERATURE SENSOR IS LOCATED IN THE SPACE. THE SENSOR
FEATURES WARMER/COOLER SETPOINT ADJUSTMENT DDC
THERMOMETER. A DIAGNOSTIC JACK WILL ALLOW FOR A PORTABLE TERMINAL
INTERFACE. THE PORTABLE TERMINAL INTERFACE IS A HAND-HELD DEVICE WHICH
GIVES THE OPERATOR THE CAPABILITY TO EDIT VAV TERMINAL BOX PARAMETERS.
WHEN COMMANDED TO CHANGE OVER TO THE UNOCCUPIED MODE, THE CONTROLLER
SHALL RAISE THE COOLING SETPOINT 60°F AND LOWER THE HEATING SETPOINT TO OPERATOR
DETERMINED VALUES. DURING UNOCCUPIED MODE, THE CONTROLLER SHALL BE RESET TO
THE OCCUPIED MODE FOR AN OPERATOR DETERMINED TIME PERIOD BY DEPRESSING THE
LOCAL OVERRIDE SWITCH PROVIDED FOR EACH ROOM OR WHEN THE OPERATOR HAS
COMMANDED IT. AT THE END OF THE TIME PERIOD, THE CONTROLLER SHALL
AUTOMATICALLY SWITCH BACK TO UNOCCUPIED MODE.
THE CONTROLLER SHALL MONITOR EACH OF THE FOLLOWING PARAMETERS OF THE TERMINAL BOX:
(1) CHILLED WATER CHILLER SERVING AIR HANDLING UNITS SHALL BE STARTED BY SIGNAL SENT
FROM THE BUILDING AUTOMATION SYSTEM OR MANUALLY BY OPERATOR UPON PROOF OF
CHILLED WATER FLOW. BUILDING AUTOMATION SYSTEM (BAS) SHALL BE ABLE TO MONITOR
CHILLER OPERATION FUNCTIONS INCLUDING SETTING POINTS AND ALL ALARM SIGNALS.
CHILLER SHALL BE PROVIDED WITH DIRECT DIGITAL CONTROLLER WHICH SHALL ALLOW CHILLER
CAPACITY MODULATION DURING COLD WEATHER. CHILLER CONTROLLER SHALL STAGE THE
OPERATIONS OF COMPRESSORS AND CONTROL CONDENSER DAMPERS AS NEEDED TO STARTUP AND
MAINTAIN STABLE OPERATIONS. CHILLER FLOW SHALL BE CONFIRMED THROUGH THE FLOW SWITCH
AT THE CHILLER.
(2) CHILLER CONTROLS SHALL MAINTAIN THE CONTROL OF THE LEAVING WATER AT 42 DEGREES, F., ADJUSTABLE AT THE OPERATOR'S WORKSTATION.
(3) A MINIMUM RUN-TIMER OF 10 MINUTES (ADJUSTABLE) SHALL BE INITIATED EACH TIME THAT THE
CHILLER IS SIGNALED TO START.
(4) CHILLER CONTROLS SHALL PROVIDE DATA OUTPUT THAT SHALL BE SENT THROUGH THE DDC SYSTEM
TO THE OPERATOR'S WORKSTATION. DATA AVAILABLE SHALL INCLUDE, AS A MINIMUM; THE
COMPRESSORS RUNNING, REFRIGERANT SUCTION AND DISCHARGE PRESSURES, THE CONDENSER
FANS RUNNING, OIL TEMPERATURE AND PRESSURE, OUTSIDE AIR TEMPERATURE, SUPPLY WATER
TEMPERATURE, AND RETURN WATER TEMPERATURE.
(5) ALARM ON CHILLER FAILURE SHALL BE MANUALLY RESET.
(6) THE BAS SHALL MONITOR KW AND CALCULATE LOAD OF THE CHILLER USING EVAPORATOR WATER
FLOW AND TEMPERATURE DIFFERENTIAL.
(7) THE BAS AND CHILLER CONTROLLER SHALL CONTROL AND MONITOR PUMPS OPERATION. UPON CALL
FOR COOLING AND CHILLER START, THE CHILLER CONTROLLER SHALL START AND OPERATE 'LEAD'
PUMP.
(CHECK VALVES IN THE PIPING SYSTEM AT THE PUMPS SHALL PREVENT SHORT-CYCLING THROUGH THE INACTIVE PUMP.)
OPERATING PUMP SHALL BE SHUTDOWN BY THE CHILLER CONTROLS AFTER THE CHILLER'S
REFRIGERANT PUMP-DOWN CYCLE HAS BEEN COMPLETED. PROVIDE SOFTWARE TO ROTATE THE
'LEAD' AND 'LAG' PUMPS.
T
CONTROLLER
TO BUILDING
AUTOMATION
SYSTEM
VARIABLE
DRIVE
SPEED
VARIABLE
DRIVE
SPEED
VARIABLE
DRIVE
SPEED
AIR HANDLING EQUIPMENT
VARIABLE AIR VOLUME AIR HANDLING UNIT - SEQUENCE OF OPERATION
1. THE RTU WILL START ON COMMAND FROM THE BAS, WHEN THE HOA SWITCH IS IN THE "AUTO" MODE. THE RTU
MAY ALSO BE STARTED LOCALLY WHEN THE HOA SWITCH IS PLACED IN THE "HAND MODE", UNTIL THAT TIME
WHEN TIMER WILL RETURN OPERATION TO HOA.
2. WHEN THE AIR HANDLER IS COMMANDED TO START THE OUTDOOR AIR DAMPER D-6 SHALL BE OPENED 100% AND
PROVE "OPEN" BASED ON INPUT FROM THE DAMPER END SWITCH, PRIOR TO STARTING THE SUPPLY AND
EXHAUST FANS. IF THE OUTDOOR AIR D-6 DOES NOT PROVE OPEN THE FAN SHALL REMAIN OFF AND AN
ALARM SHALL BE ROUTED TO THE OPERATOR'S WORKSTATION.
3. WITH THE OUTDOOR D-6 VERIFIED OPEN THE VFD SHALL START AND MODULATE THE SUPPLY. EXHAUST FANS
SHALL RAMP UNP IN SEQUENCE TO CFM ESTABLISHED BY TAB.
CURRENT TRANSFORMER (CT) SWITCHES SHALL SIGNAL THE CONTROLLER TO VERIFY OPERATION OF THE
SUPPLY AND EXHAUST FANS. IF SUPPLY FAN OPERATION IS NOT VERIFIED WITHIN 30 SECONDS (CUSTOMER
ADJUSTABLE) THEN THE UNIT SHALL BE SHUT DOWN AND AN ALARM BE ROUTED TO THE OPERATORS
WORKSTATION. IF THE EXHAUST FAN OPERATION IS NOT VERIFIED THE UNIT SHALL CONTINUE TO OPERATE AND
AN ALARM SHALL BE ROUTED TO THE OPERATORS WORKSTATION.
4. THE RTU SHALL STOP WHEN COMMANDED BY THE BAS, OR WHEN THE HOA SWITCH IS PLACED IN "HAND". THE
UNIT SHALL SHUT DOWN BY FIRST COMMANDING OFF THE FAN VFDS, WHEN THE FANS ARE PROVEN OFF (BY THE
CT INPUT) THE OUTDOOR AIR DAMPER SHALL THEN BE CLOSED. WHILE IN THE OFF MODE HEAT EXCHANGER
WILL BE OFF.
5. THE RTU WILL STOP (FANS OFF, OUTDOOR DAMPER D-6 CLOSED, HEAT EXCHANGER OFF) AND AN ALARM BE ROUTED TO
THE OPERATORS WORKSTATION WHEN ANY OF THE FOLLOWING CONDITIONS OCCUR:
A. IF EMERGENCY STOP SWITCH IS IN "PUSHED" POSITION, THEN THE SWITCH MUST BE MANUALLY "PULLED" IN
ORDER TO RESTART RTU.
B. IF HIGH DISCHARGE PRESSURE SWITCH LOCATED IN THE UNIT AND AFTER THE SUPPLY FAN IS TRIGGERED DUE
TO HIGH PRESSURE, THE RTU SHALL SHUT DOWN AND WILL NOT RESTART AUTOMATICALLY. (HIGH STATIC
PRESSURE SWITCH SHALL BE SET ACCORDING TO TEST & BALANCE'S INSTRUCTION.)
C. IF THE VAPOR TENSION LOW LIMIT THERMOSTAT ("FREEZESTAT") SENSES A TEMPERATURE BELOW 35
DEGREES (SHALL REQUIRE A MANUAL RESET). DURING THIS TIME DDS SHOULD SEND A SIGNAL TO OPEN UP 3-WAY CHILLED
WATER VALVE TO THE COOLING COIL AND START UP ONE OF THE CHILLED WATER PUMPS FOR CIRCULATION.
D. SMOKE MODE - IF ANY OF THE DUCT MOUNTED SMOKE DETECTORS (FURNISHED BY DIVISION 28) AND
INSTALLED IN THE SUPPLY, EXHAUST AND OUTSIDE AIR STREAMS DETECT SMOKE OR A SPACE DETECTOR
DETECTS SMOKE. UNIT SHALL RESTART WHEN THE ALARM CLEARS.
(8) PUMPS SHALL BE ALTERNATED TO EQUALIZE EQUIPMENT RUNTIME. SELECTION OF THE LEAD AND SECOND
PUMP IS EVALUATED ON A WEEKLY BASIS. THE PUMP WITH THE LEAST RUNTIME IS THE LEAD. THE
REMAINING PUMP IS LAG. IN THE EVENT THAT THE LEAD PUMP FAILS (AS DETECTED BY A CURRENT
TRANSDUCER) THE LAG PUMP SHALL START AND AN ALARM SHALL BE ROUTED TO THE OPERATORS
8. AIR FILTERS
1. A DIFFERENTIAL PRESSURE SWITCH SHALL MONITOR STATIC PRESSURE ON THE ENTERING
AND LEAVING SIDE OF AIR FILTER BANKS. THE SET -POINT VALUE SHALL BE CONNECTED TO
TO UNIT DDC CONTROLLER AND ENABLE AN ALARM AT THE COMPUTER CONSOLE WHEN FILTERS
NEEDS TO BE REPLACED ACCORDING TO MANUFACTURERS RECOMMENDATIONS.
A. WHEN AVERAGE SPACE TEMPERATURE FALLS BELOW UNOCCUPIED HEATING SETPOINT OF 60 DEG. F (ADJ.) THE SUPPLY FAN WILL START, EXHAUST FAN WILL BE OFF. THE OUTSIDE AIR DAMPER D-6 REMAIN CLOSED AND HEATING COIL CONTROL VALVE WILL MODULATE
B. WHEN AVERAGE SPACE TEMPERATURE RISES ABOVE UNOCCUPIED COOLING SETPOINT OF 85 DEG. F (ADJ.) THE SUPPLY FAN WILL START THE OUTSIDE AIR DAMPER D-6 WILL REMAIN CLOSED. EXHAUST FAN WILL BE OFF AND HEATING COIL VALVE WILL BE CLOSED.
9. UNOCCUPIED MODE
TO HOLD A SET POINT (ADJ.) ALL R.A. DAMPERS SHALL BE OPEN. HEAT EXCHANGER SHALL BE DE-ENERGIZED.
COOLING COIL CONTROL VALVE WILL MODULATE TO HOLD A SET POINT OF 85 DEG. F (ADJ.). ALL R.A. DAMPERS SHALL BE OPEN. ENERGY
WHEEL SHALL BE DE-ENERGIZED.
RTU-1, RTU-2 UNITS CONTROL SCHEMATIC
EXHAUST FANS
SUPPLY
DAMPER
EXHAUST
DAMPER
RETURN AIR
DAMPER
LOCATE 2/3 DOWNSTREAM
OF SUPPLY DUCT
1. CONTROL CONTRACTOR SHALL PROVIDE AND INSTALL DDC CONTROLLER FOR EACH ROOFTOPO UNIT.
2. DURING AIR BALANCING PROCEDURE CONTRACTOR SHALL ACHIEVE HEAT EXCHANGER TO HAVE SUPPLY SIDE UNDER POSITIVE
EXHAUST SIDE UNDER NEGATIVE PRESSURES.
NOTES:
BY-PASS DAMPER
RETURN
DAMPER
WALL-MOUNTED
TEMPERATURE SENSOR
W/
SETPOINT ADJUSTMENT
ELECTRIC
REHEAT COIL
SUPPLY AIR
TO SPACE
120/1PH
TO RTU CONTROLLER
AIRFLOW
MEASURING
DEVICE
VOLUME
REGULATOR
H
C
SUPPLY AIR
FROM RTU
ANALOG
INPUT SIGNAL
B. THE EXHAUST FAN AIRFLOW SHALL MEASURED WITH THE AIRFLOW MONITORS IN THE UNIT
THE EXHAUST FAN AIR FLOW SHALL BE ESTABLISHED AT FINAL TEST AND
BALANCE TO KEEP THE BUILDING AT SLIGHTLY POSITIVE PRESSURE.
C. THE EXHAUST FAN(S) SHALL RUN CONTINUOUSLY WHEN OUTSIDE AIR DAMPER D-6 IS OPEN
AND SUPPLY FAN IS RUNNING.
TYPICAL TERMINAL UNIT CONTROL DIAGRAM
AIR TO AIR PLATE
AND FRAME HEAT
EXCHANGER
DP DP
FILTER
H-ETS
COOLING
COIL
T-LL
FILTER
SD
HSTS
L
AFMS
H
D-5
NO
SUPPLY FAN
PRE- ELECTRIC
HEAT
ELECTRIC
CONTROLLER
LL-1
CHWSCHWR
NC
V-2
TS
FINAL
L
AFMS
H
L H
P-FF
L H
P-PF
HS
NC
D-7
TS HS
SPL
AFMS
H
AFMS
D-6
NC
NO
D-2
TS
TS-MIX
COMPUTER ACCESS120V/1PH POWER SUPPLY
DB1
DB-2
BY-PASS
D-4
NO
D-1
NO
BO
VFD-SF
VFD-CHWP
SD-EA
H-E
AFMS
DB-1
ON-OFF
VFD-EF
SD
T-CC
HSL
SP
P-PF
P-FF
D-1
T-RA
H-RA
H-MIX
H-OA
H-SA
T-LL
T-HC
T-MIX
T-OA
T-SA
H-RA
H-OA H-SA
TS HS
HS-MIX
H-MIX
SP
HSLTS
TS-CC
TS
TS-HC
T-OA
T-RA
T-SA
ESS
T-1
ECC
DAMPER
L
AFMS
H
(1)
C. VARIABLE AIR VOLUME TERMINAL UNITS (VAV BOXES)
(a)
(b)
(c)
(3)
(2)
7. SUPPLY AIR AND EXHAUST AIR FANS SPEED CONTROL: SUPPLY & EXHAUST FAN MOTORS VARIABLE FREQUENCY DRIVES SHALL
CONTROL EACH FAN AIR FLOW RATE.
A. STATIC PRESSURE SENSOR SHALL BE LOCATED 2/3 OF THE WAY DOWN THE LONGEST MEDIUM PRESSURE DUCT RUN AND IN AN
EASILY-ACCESSIBLE LOCATION. THIS SENSOR SHALL SEND A SIGNAL TO THE DDC SYSTEM FOR CONTROL OF THE SUPPLY AIR FANS
SPEED. UPON A FALL IN THE DUCT STATIC PRESSURE, BELOW THE DYNAMIC SETPOINT (SEE BELOW), THE SPEED OF THE SUPPLY
AIR FANS SHALL BE INCREASED. UPON A RISE IN THE DUCT STATIC PRESSURE, ABOVE THE DYNAMIC SETPOINT, THE SPEED OF
THE SUPPLY AIR FANS SHALL BE REDUCED.
THE CENTRAL GRAPHICS CONSOLE AND ANY OTHER OPERATOR'S CONSOLE SHALL BE
CAPABLE OF DISPLAY AND CONTROL OF EACH OF THESE PARAMETERS. THE PORTABLE
DISPLAY TERMINAL CONNECTED TO THE CONTROLLER SHALL ALSO BE ABLE TO MONITOR
AND CONTROL THESE PARAMETERS.
PROVIDE A GRAPHIC FOR EACH ROOM SHOWING FLOOR PLAN, ROOM TEMPERATURE AND
ROOM SETPOINT. THESE SHALL BE ARRANGED SO THAT THE OPERATOR SHALL "CLICK ON
THE ROOM" AND A WINDOW SHALL APPEAR ALLOWING ANY OF THE PARAMETERS
AVAILABLE ON THE CONTROLLER TO BE SELECTED AND MODIFIED BY THE POINTING OF A
THESE ROOM GRAPHICS SHALL BE GROUPED TOGETHER IN FLOOR QUADRANTS.
THE ROOM'S COLOR SHALL INDICATE GREEN IF THE ROOM TEMPERATURE IS WITHIN ALARM
RANGE AND IT SHALL INDICATE RED IF THE ROOM TEMPERATURE IS ABOVE OR BELOW
ALARM RANGE. THE QUADRANT GRAPHIC SHALL CONTAIN A SMALL LAYOUT OF THE TOTAL
FLOOR AND SHALL SHOW THE PRESENTLY DISPLAYED GRAPHIC'S REACTION TO THE REST
OF THE FLOOR. ALSO LOCATED ON THE QUADRANT GRAPHIC SHALL BE "QUICK LINKS" TO
THE QUADRANTS OF THIS AND OTHER FLOORS.
(4)
(5)
BAS PANEL
BUILDING
CONTROLLER
ASC ASC ASC
ASC ASC ASC
RTU-1 CONTROLLER
RTU-2 CONTROLLER (BC)BACNET IP NEW FIBER TO
ECC IN BUILDING 100
120V AC BY
DIV. 26
BACNET MS/TP
CONTROLS SYSTEM ARCHITECTURE
BACNET IP TO BAS PANEL
APPLICATION SPECIFIC
CONTROLLERIR
120V AC
BY DIV. 26
120V BY DIV 26
NOTE:
1. CONTROL POWER SHOWN IS BASIS OF DESIGN. ADDITIONAL POWER FOR CONTROL PANELS
ADDED BY THE TEMPERATURE CONTROLS CONTRACTOR ARE TO BE PROVIDED AND
INSTALLED BY DIV. 26.
AUTOMATIC CALIBRATION IS ACCOMPLISHED THROUGH THE CONTROLLER AUTO ZERO
FEATURE. THIS FEATURE CALIBRATES THE AIRFLOW SENSOR. THE AUTO ZERO FEATURE
CAN BE COMMANDED FROM THE BMS OR CAN BE SCHEDULED. THIS FEATURE OVERRIDES
THE DAMPER ACTUATOR CLOSED WHILE PERFORMING AUTO ZERO. WHEN THE DAMPER IS
FULLY CLOSED, THE PRESENT VALUE OF DELTA P SENSOR IS READ INTO THE AI OFFSET
TABLE.
(6)
277/480
EXHAUST AIR
DAMPER
OUTSIDE AIR
DAMPER
BUILDING WARM UP AND COOL DOWN SHALL START AT PREDETERMINED TIME BY OWNER SCHEDULE
AND FOLLOW NORMAL START-UP/SHUTDOWN OPERATIONS AS DESCRIBED IN SEQUENCE OF OPERATIONS.
10.
(9) CHILLED WATER PACKAGE SYSTEM ELECTRIC HEATER SHALL BE CONTROLLED BY MANUFACTURER PROVIDED THERMOSTAT
AND SET AT 80°F (ADJUSTABLE).
(10) EXHAUST FAN SHALL BE CONTROLLED BY EXTERIOR WALL MOUNTED "ON-OFF" SWITCH.
(a) SUPPLY AIR TEMPERATURE
(b) SUPPLY AIR VOLUME
(c) SUPPLY DAMPER CONTROL
(d) SUPPLY DAMPER CONTROL
(e) REHEAT VALVE CONTOL
(f) ROOM TEMPERATURE
(g) ROOM TEMPERATURE COOLING SETPOINT
(h) ROOM TEMPERATURE HEATING SETPOINT
(i) UNOCCUPIED TEMPERATURE DEADBAND
(j) SUPPLY AIR VOLUME MAXIMUM FLOW
(k) SUPPLY AIR VOLUME MINIMUM FLOW
(l) LOCAL OCCUPIED OVERRIDE SWITCH
(a) DURING ECONOMIZER MODE, THE CONTROLLER SHALL DISABLE MECHANICAL COOLING AND UTILIZE RTU DAMPERS TO
MAINTAIN DISCHARGE AIR TEMPERAURE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/9
/2
:1
:5
P
M
M005
MECHANICAL - SEQUENCE OF
OPERATIONSCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
FD
F D
FD FD
D D
D D
S S
S S
S S
S
S
SSSSS
S S S S S
S
SS
S S
S
SSS
S S S
E
A
D
D.6
B
7 8 10 11 12654321 6.3 6.6
CONFERENCE
1A059
OPHTH CHIEF
1A052
YAG LSR
1A049
PRE-OP EX 2
1A032
PRE-OP EX 1
1A034
EX 4
1A025
PHOTO
1A045
EX 7
1A042EX 5
1A088
EX 6
1A086
EX 7
1A084
EX 8
1A077
EX 3
1A095
EX 4
1A097
TLT
1A112
TLT
1A106
RME DROP-OFF
1A073
LOW VIS
1A064
RECEPTION
1A006
HAC
1A104
MECH
1A092
VF 1
1A081
EYEGLASS FIT D&D
1A103
WAITING
1A101
VEST
1A001
WAITING
1A011
OCT 2
1A027
VF 1
1A047
NURSE WKRM
1A026
EX 3
1A028
COMM
1A016
EQPT ALC
1A031
EX 9
1A076
EX 10
1A074
EX 11
1A072
LOUNGE
1A056
EX 10
1A048
EX 9
1A046
EX 8
1A044
CORR
1A090
CORR
1A080
LOBBY
1A000
CORR
1A040
CORR
1A020
CORR
1A070
LOCKER
1A056A
SHARED OFF
1A087
SHARED OFF
1A078
SHARED OFF
1A054
EX 12
1A068
BROS
1A002
VIST
1A004
SHARED OFF
1A058
ELEC
1A108
TLT
1A012
TLT
1A057
TLT
1A014
EX 6
1A043
HAC
1A041
VEST
1A021
ELEC
1A024
CORR
1A030
COMM
1A102
HLD STOR
1A069
TLT
1A075
REPROCESS
1A071
WHCH ALC
1A101A
MED PREP
1A067
EX 5
1A023
TLT
1A055
VALVE
1A089
WHCH ALC
1A011A
EX 1
1A094
VEST
1A091
EX 2
1A093
OCT 1
1A085
OCT 2
1A083
VF 2
1A079
PROCEDURE
1A022
CORR
1A100
CORR
1A010
SHARED OFF
1A062
SHARED OFF
1A082
EX 13
1A066
OCT 1
1A029
COPY
1A006A
RTU-1 ON
ROOF
RTU-2 ON ROOF
KEY PLAN: (DO NOT SCALE)
AREA OF WORK
PLAN
NORTH
GRAPHIC SCALE
( in Feet )
1 inch = 8 ft.
8 84 16 32
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/2
/2
:4
:0
A
M
MH100
MECHANICAL - FIRST FLOOR PLAN -
DUCTWORK - OVERALLCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
09/29/2023 GAT CAC
1/8" = 1'-0"
MECHANICAL - FIRST FLOOR PLAN - DUCTWORK - OVERALL
FOR REFERENCE ONLY. REFER TO MH100A AND MH100B
FOR DUCTWORK SIZES, AND AIR FLOWS.
T
T
T
T
T
T
T TT
T
T T T
T
T
T
T
T
T
T
T
T
T
T
T
T T
T
T
T
TT
T
T
T
T
S S
S S
S S
S
S
SSSSS
S S S S S
S
SS
S S
S
SSS
S S S
E
A
D
D.6
B
7 8 10 11 12654321 6.3 6.6
CONFERENCE
1A059
388 SF
OPHTH CHIEF
1A052
132 SF
YAG LSR
1A049
188 SF
PRE-OP EX 2
1A032
132 SF
PRE-OP EX 1
1A034
130 SF
EX 4
1A025
131 SF
PHOTO
1A045
131 SF
EX 7
1A042
131 SF
EX 5
1A088
131 SF
EX 6
1A086
132 SF
EX 7
1A084
132 SF
EX 8
1A077
131 SF
EX 3
1A095
131 SF
EX 4
1A097
127 SF
TLT
1A112
67 SF
TLT
1A106
71 SF
LOW VIS
1A064
296 SF
RECEPTION
1A006
141 SF
HAC
1A104
67 SF
MECH
1A092
138 SF
VF 1
1A081
85 SF
EYEGLASS FIT D&D
1A103
418 SF
WAITING
1A101
373 SF VEST
1A001
76 SF
WAITING
1A011
237 SF
OCT 2
1A027
65 SF
VF 1
1A047
131 SF
NURSE WKRM
1A026
115 SF
EX 3
1A028
132 SF
COMM
1A016
90 SF
EQPT ALC
1A031
48 SF
EX 9
1A076
132 SF
EX 10
1A074
132 SF
EX 11
1A072
132 SF
LOUNGE
1A056
158 SF
EX 10
1A048
132 SF
EX 9
1A046
132 SF
EX 8
1A044
132 SF
CORR
1A090
245 SF
CORR
1A080
171 SF
LOBBY
1A000
517 SF
CORR
1A040
650 SF
CORR
1A020
452 SF
CORR
1A070
1104 SF
LOCKER
1A056A
36 SF
SHARED OFF
1A087
111 SF
SHARED OFF
1A078
176 SF
SHARED OFF
1A054
132 SF
EX 12
1A068
132 SF
BROS
1A002
152 SF
VIST
1A004
115 SF
SHARED OFF
1A058
112 SF
ELEC
1A108
22 SF
TLT
1A012
63 SF
TLT
1A057
75 SF
TLT
1A014
53 SF
EX 6
1A043
132 SF
HAC
1A041
46 SF
VEST
1A021
62 SF
ELEC
1A024
110 SF
CORR
1A030
172 SF
COMM
1A102
100 SF
HLD STOR
1A069
61 SF
TLT
1A075
72 SF
REPROCESS
1A071
69 SF
WHCH ALC
1A101A
21 SF
MED PREP
1A067
69 SF
EX 5
1A023
132 SF
TLT
1A055
87 SF
VALVE
1A089
44 SF
WHCH ALC
1A011A
21 SF
EX 1
1A094
132 SF
VEST
1A091
62 SF
EX 2
1A093
132 SF
OCT 1
1A085
74 SF
OCT 2
1A083
73 SF
VF 2
1A079
87 SF
PROCEDURE
1A022
152 SF
CORR
1A100
465 SF
CORR
1A010
251 SF
SHARED OFF
1A062
113 SF
SHARED OFF
1A082
173 SF
EX 13
1A066
132 SF
OCT 1
1A029
65 SF
COPY
1A006A
78 SF
R R
1-1-13V
130 CFM
1-1-1V
620 CFM
1-1-4V
530 CFM
1-1-5V
400 CFM
1-1-6V
470 CFM
1-1-10V
220 CFM
1-1-7V
840 CFM
1-1-8V
560 CFM
1-1-9V
600 CFM
1-2-11V
400 CFM
1-2-10V
380 CFM
1-2-9V
250 CFM
1-2-8V
380 CFM
1-2-15V
500 CFM
1-2-17V
325 CFM
1-2-4V
360 CFM
1-2-3V
190 CFM
1-2-16V
160 CFM
1-2-2V
630 CFM
1-2-6V
420 CFM
AC-2
1-2-1V
800 CFM
1-2-12V
680 CFM
1-2-13V
630 CFM
1-2-18V
420 CFM
1-1-12V
250 CFM
1-1-11V
670 CFM
1-1-2V
1400 CFM
AC-1
E S
S
TO RTU-1
EH-1 EH-2
TO RTU-2
E S
S
B A
S
RTU-1 ON ROOF RTU-2 ON ROOF
1-1-14V
360 CFM
1-2-7V
570 CFM
1-2-14V
210 CFM
R
RME DROP-OFF
1A073
51 SF
HAC
1A073H
19 SF
1-1-15V
190 CFM
1-1-3V
460 CFM
1-2-5V
420 CFM
1 1/2"D
3/4"D
/4
"D
1 1/2"D
/4
"D
KEY PLAN: (DO NOT SCALE)
AREA OF WORK
PLAN
NORTH
GRAPHIC SCALE
( in Feet )
1 inch = 8 ft.
8 84 16 32
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C R
E V
IT
F
IL
E
S \R e v it
\3
.0
-C
E C e n tr a l M o d e l.
rv t
/2
/2
:4
:0
A
M
MH100.1
MECHANICAL - FIRST FLOOR PLAN -
VAV ZONE PLAN - OVERALLCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
09/29/2023 GAT CAC
1/8" = 1'-0"
MECHANICAL - FIRST FLOOR PLAN - VAV ZONE PLAN - OVERALL
FOR REFERENCE ONLY. REFER TO MH100A AND MH100B
FOR DUCTWORK SIZES AND AIRFLOWS.
S S S
FD
F D
D D
S S
S S
S S
S
S
SSSSS
S S S
INSTALL 10 FT LONG LINEAR BAR GRILLE, 0° DEFLECTION, TO SUPPLY 1,100 CFM. PROVIDE GRILLE WITH 14"x12"(H) SHEET METAL PLENUM WITH 1/2" LINER. MC TO FABRICATE
PLENUM. PROVIDE PLENUM WITH (3) THREE 10" DIAMETER DUCT INLETS AND CONNECT
INLET DUCTS TO MAIN SUPPLY DUCT. INSTALL BALANCING DAMPER AT EACH INLET TO THE
PLENUM. COORDINATE EXACT BAR GRILLE LOCATION AND ELEVATION WITH PROJECT
ARCHITECT.
28"x28" S.A. DUCT UP TO RTU-1 LOCATED ON ROOF. INSTALL DUCT FITTINGS TO CONNECT
S.A. DUCT TO UNIT S.A. OPENING AT THE BOTTOM.
44"x22" R.A. DUCT UP TO RTU-1 LOCATED ON ROOF. INSTALL DUCT FITTINGS TO CONNECT
R.A. DUCT TO UNIT R.A. OPENING AT THE BOTTOM.
44"x22" E.A. DUCT UP TO RTU-1 LOCATED ON ROOF. INSTALL DUCT FITTINGS TO CONNECT
E.A. DUCT TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .