Attachment 11 - 544-329 Equipment Cut Sheets Part 5.pdf

PDF 25 MB Posted

Attached to
Y1DZ--VHA MINOR CONSTRUCTION Solicitation CANCELLED Project 544-329 Construct Eye Clinic Center Minor Construction Columbia, SC VAMC
Solicitation number
36C77624R0028
Issued by

About this file

This document appears to be Attachment 11 - 544-329 Equipment Cut Sheets Part 5.pdf, which is related to the federal contract opportunity for the Y1DZ--VHA MINOR CONSTRUCTION Solicitation Project 544-329 Construct Eye Clinic Center Minor Construction Columbia, SC VAMC.

The key details are:

The intent of this project is to construct a new, 15,000 gross square foot (GSF) optometric facility at the William Jennings Bryan Dorn VA Medical Center in Columbia, SC. The project will address the needs of VA patients and employees with a building tailored to the functional and operational needs of the Optometry and Ophthalmology departments. The project will include new construction, HVAC, utility work, interior finishes, utility coordination, site work, underground storm water detention, asbestos and lead survey and abatement, and communication utility work inside an active hospital. The solicitation number is 36C77624R0028 and the contracting agency is the Department of Veterans Affairs Technology Acquisition Center Austin.

View the file

Other files

File Type Posted
36C77624R0028 0007 - Signed.pdf PDF
36C77624R0028 0006 - Signed.pdf PDF
36C77624R0028 0005 - Signed.pdf PDF
Technical Questions Tracking Spreadsheet - 9-3-24- 36C77624R0028 - Construct Eye Clinic Columbia SC.docx DOCX document
RoomFinishes.pdf PDF
2024-08-29 544-329 BID DRAWING REVISIONS.pdf PDF
South Carolina Tax Language - 04.04.2024 - FINAL.docx DOCX document
01 00 00 General Requirements_rev 2_8.29.24.pdf PDF
36C77624R0028 0004 - Signed.pdf PDF
09 91 00 Painting_Rev 1 8.30.24.docx DOCX document
544 329 SOW 100_rev2.pdf PDF
00 01 10 Table of Contents_Rev 1 8.30.24.docx DOCX document
Attachment 6 - 544-329 Eye Clinic CD Specs 8.19.24.pdf PDF
SIGN IN SHEET Site Visit 8.15.24.pdf PDF
Amendment 0003 - 36C77624R0028 - Construct Eye Clinic - Columbia SC 8.19.24 - Signed.pdf PDF
Solicitation - 36C77624R0028 - Construct Eye Clinic - Columbia SC 8.19.24.pdf PDF
Attachment 7 - 544-329 Equipment Cut Sheets Part 1.pdf PDF
Attachment 24 - Richland County Wage Rates 6.14.24.pdf PDF
Attachment 9 - 544-329 Equipment Cut Sheets Part 3.pdf PDF
Attachment 28 - Division Cost Breakdown - 5-29-24.xlsx XLSX spreadsheet
Attachment 22 - Site Visit Dorn VAMC Google Map.jpg JPG image
Attachment 20 - 2023-09-29 544-329 BID DRAWINGS_Part7.pdf PDF
Attachment 18 - 2023-09-29 544-329 BID DRAWINGS_Part5.pdf PDF
Attachment 17 - 2023-09-29 544-329 BID DRAWINGS_Part4.pdf PDF
Attachment 3 - 544 329 VAMC Columbia SC Asbestos Inspection columbia part 1.pdf PDF
Attachment 26 - 544 329 SOW 100_rev1.pdf PDF
Attachment 5 - 544 329 VAMC Columbia SC Asbestos Inspection Report All Buildi.pdf PDF
Attachment 6 - 544-329 Eye Clinic CD Specs_120823.pdf PDF
Attachment 10 - 544-329 Equipment Cut Sheets Part 4.pdf PDF
Solicitation - 36C77624R0028 - Construct Eye Clinic - Columbia SC 8-8-24.pdf PDF
Attachment 12 - 544-329 Equipment Cut Sheets Part 6.pdf PDF
Attachment 23 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 27 - 544 329 Brand Name J and A.pdf PDF
Attachment 2 - 544 329 Eye Clinic Equipment List.xlsx XLSX spreadsheet
Attachment 8 - 544-329 Equipment Cut Sheets Part 2.pdf PDF
Attachment 1 - 544 329 Eye Clinic ConstructionAssessmentPackage 100 Percent.pdf PDF
Attachment 21 - Site Visit Dorn VAMC Campus Map_B101 and Contractor Parking.pdf PDF
Attachment 14 - 2023-09-29 544-329 BID DRAWINGS_Part1.pdf PDF
Attachment 25 - VHA Supplemental Contract Requirements for Combatting COVID-19 Updated 6-2024.docx DOCX document
Attachment 16 - 2023-09-29 544-329 BID DRAWINGS_Part3.pdf PDF
Attachment 4 - 544 329 VAMC Columbia SC Asbestos Inspection columbia part 2.pdf PDF
Attachment 15 - 2023-09-29 544-329 BID DRAWINGS_Part2.pdf PDF
Attachment 13 - 544-329 Geotech Report.pdf PDF
Attachment 19 - 2023-09-29 544-329 BID DRAWINGS_Part6.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7www.fs.com

STANDARD FIBER PATCH CABLES DATASHEET

ID Description

#40191 1m (3ft) LC UPC to LC UPC Duplex OS2 Single Mode PVC (OFNR) 2.0mm

#40446 1m (3ft) LC UPC to LC UPC Simplex OS2 Single Mode PVC (OFNR) 2.0mm

#43134 1m (3ft) LC UPC to LC UPC Duplex OM2 Multimode PVC (OFNR) 2.0mm

#41730 1m (3ft) LC UPC to LC UPC Duplex OM3 Multimode PVC (OFNR) 2.0mm

#40180 1m (3ft) LC UPC to LC UPC Duplex OM4 Multimode PVC (OFNR) 2.0mm

#141727 1m (3ft) LC UPC to LC UPC Short Boot Duplex OM4 Multimode PVC (OFNR) 2.0mm

#130953 1m (3ft) LC UPC to LC UPC Short Boot Duplex OS2 Single Mode PVC (OFNR) 2.0mm

#130973 Customized OS2 Single Mode LC/SC Short Boot

#141842 Customized OM3 Multimode LC/SC Short Boot

Hot Products

Connectors Boot Type Introduction

1. LC Boot Type

• Standard Boot (28.5mm) • Short Boot (18mm) • Short Boot (12mm)

• Standard Boot (41mm) • Short Boot (25mm)

2. SC Boot Type

Appendix P

CONSTRUCTION & DIMENSIONS -

CONDUCTOR PARAMETER -

• Number of Conductors 2

• AWG Size 16

• Conductor Stranding Solid

• Conductor Type Bare Copper

• Nominal DCR 4.1 Ohm/1000ft

INSULATION PARAMETER -

• Insulation Type Polypropylene - PP

• Insulation Thickness 0.015 in

• Insulation Color Code 1. Black 2.Red

SHIELDING PARAMETER -

• Shield Type None

ELECTRICAL CHARACTERISTICS -

• Nom. Cap. Between Conductors 17 pF/ft

OVERALL CONSTRUCTION PARAMETERS -

Jacket Type PVC

Jacket Thickness 0.030 in

Nominal Cable O.D. 0.223 in

Plenum No

NEC UL Rating FPLR

RoHS Compliant Yes

Pull Tension 62 lbs

Bend Radius 2.007 in

Cable Weight 29 lbs

OVERALL ELECTRICAL/OPTICAL CHARACTERISTICS -

UL Flammability UL1666 Vertical Shaft

Operating Range -20 to 60 Deg C

UL Voltage Rating 300

Construction & Dimensions

Overall Construction

Overall Electrical & Optical Characteristics

Detailed Specification & Technical Data

D990

Addressable Fire Alam SLC Circuits

2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com

16/2 Unshielded Low Capacitance FPLR Rated CABLE TYPE G

RELATED PRODUCTS -

Plenum Number D60991

Related Products

Detailed Specification & Technical Data

2833 West Chestnut Street | Washington, PA 15301 | Toll Free: 800-245-4964 | www.westpenn-wpw.com

D990

Addressable Fire Alam SLC Circuits 16/2 Unshielded Low Capacitance FPLR Rated

I99998 Cat 6E 550 CMR SPEC 70457

23 AWG /4 Pair CAT6E CMR Cable

CONSTRUCTION:

1. Conductors: 23 AWG SOLID BARE COPPER

2. Insulation: HIGH DENSITY POLYETHYLENE COLORS: BLUE & WHITE/BLUE STRIPE; ORANGE & WHITE/ORANGE STRIPE; GREEN & WHITE/GREEN STRIPE; BROWN & WHITE/BROWN STRIPE

3. Assembly: 4 PAIRS INDIVIDUALLY TWISTED, CABLED; UNSHIELDED; AND JACKETED

4. Jacket: PVC, Color : Consult factory for jacket color options.

APPLICATIONS AND FEATURES:

SPECIFICATIONS:

• Meets or exceeds TIA/EIA 568-C.2

• NEC ARTICLE 800

• Passes IEEE 802.3af

• UL 444 CMR

• UL 1666 RISER FLAME TEST

• Directive (EU) 2015/863 – RoHS 3

SAMPLE PRINT LEGEND:

PACKAGING Standard lengths 1000 FT. Consult factory for packaging options.

TABLE 1 - Product Electrical Characteristics

3.3 9.38 45.0 68.0 100 +/- 15% 0.236 5.994 28.0 41.7

All dimensions are nominal and subject to nominal manufacturing tolerances

SPEC 70457 Date: 11/6/2019 Rev1

The information presented here is, to the best of our knowledge, true and accurate. Since conditions of use are beyond Southwire's control all product data presented is for informational purposes only and does not create a binding obligation or liability on Southwire or confer any rights on any customer. The sale of products(s) is conditioned upon acceptance of a purchase order subject to Southwire's standard terms and conditions contained therein, including without limitation Southwire's standard warranty. Southwire disclaims all liability in connection with the use of information contained herein or otherwise.

75°C, 300V 550MHz RISER RATED; 4 UNSHIELDED TWISTED PAIRS

Southwire Cat 6E unshielded twisted pair cable is a high performance data communication cable. This ethernet cable is designed for indoor and riser network installations type CMR (Riser rated communication cable), may be used in Ethernet Networking system, PoE applications, Video MPEG4 /

M‐JPEG / Digital / Analog / Baseband / Broadband and other Multimedia Voice applications.

Max Delay Skew

(ns/100m)

Nom Velocity of

Propagation (%)

Characteristic

Impedance

(Ω @ 1-100 MHz)

Max Capacitance

(nF/100m @ 1 kHz)

(AWG)

Max DC Resistance

(Ω/100m @ 68°F)

The customer will accept all factory lengths and +/- 10 percent of total order requested.

6EP SOUTHWIRE® TAPPAN(TM) CAT6E 23 AWG 4PR UTP E118871 C(UL)US CMR 75C -- TYPE CMR ETL VERIFIED TO TIA/EIA-568-C.2

CATEGORY 6E 550MHZ ROHS-3 COMPLIANT -- SEQ FTG -- XX/XX/XX(MONTH/DAY/YEAR) HH:MM(HOUR/MINUTE)

Nominal

Weight

(kg/km)

Stock

Code

I99998

Nominal

OD (Inchs)

Nominal

OD (mm)

Nominal

Weight

(Lbs/Mft)

CABLE TYPE H & J

50 Technology Drive Westminster, Ma 01441-0001

(978) 731-2500

FAX: (978) 731-7856

Johnson Controls Material List (THIS IS NOT A PRICE QUOTATION)

TO:

MSS Solutions, LLC Project: Dorn VA BLDG 10 EnGauge 1001 Tuckaseegee Rd Customer Reference: EnGauge Extinguisher Monitoring PO Box 32607 Johnson Controls Reference: L40862-000155 CHARLOTTE, NC 28208-2607 Proposal #: P40862-000151

Date: 12/14/2020 Attn: Kyle Williamson Page 1 of 1

This quote reflects Federal Government/Non GSA Pricing. Johnson Controls Fire Protection LP offers

GSA pricing to GSA authorized, eligible, ordering entities. Please contact your sales representative if you have any questions.

QUANTITY MODEL NUMBER DESCRIPTION

EnGauge Equipment 15 F00170 10LB ABC Extinguisher

15 1015F10 AMB/FULL GLASS FLAT CAB

15 F00133 EVM (en-Vision Module) Kit

AMBASSADOR™ IS A TRADEMARK OF ACPG

DOWNLOAD CURRENT SUBMITTAL BEFORE ORDERING

Distributor: Quantity:

Contractor: Approved By:

Model #: Architect:

Project: Date: © 2017 Activar Construction Products Inc

HEADQUARTERS:9702 NEWTON AV S, BLOOMINGTON, MN 55431

MANUFACTURING: BLOOM NGTON MN & COMMERCE, CA ● WAREHOUSES: FT MYERS FL, ATLANTA GA, DALLAS TX, SEATTLE WA, LANCASTER PA, FARGO ND, OMAHA NE 6/13/17

SUBMITTAL: AMBASSADOR™ STEEL FIRE EXTINGUISHER CABINETS PAGE 1 OF 2

STEP 1: SELECT MODEL NUMBER AND QUANTITY ON CHART (refer to chart on page 2) A. Determine Trim Style according to wall depth.

B. Determine Tub I.D. according to size most suited for extinguisher and wall opening.

STEP 4: OPTIONAL FEATURES AT ADDED COST (SELECT ANY)

Optional Tub Color: ____ Black _____Red Black Vertical FE Letters LDCVBFE Black Vertical Decal LDVBFE (CA) Commander Alarm

Futura “Fire” Pull ____ Mill Alum _ Red ____ White Red Vertical FE Letters LDCVRFE Red Vertical Decal LDVRFE (BA) Brigadier Alarm

Flush Pull Handle White Vertical FE Letters LDCVWFE White Vertical Decal LDVWFE (SA) Strobe Alarm (Surface Mount Models)

Polished Chrome Handle (PUCH) Black Horizontal FE Letters LDCHBFE Black Horizontal Decal LDHBFE Etched/Engraved Lettering in Glass or Metal- Attach Sub.

Optional Colors: Red ___ Black ___ Flat Black Red Horizontal FE Letters LDCHRFE Red Horizontal Decal LDHRFE Rolled Edge Surface Mount- See Separate Submittal

___ Sand AMS Beige SC Flat Beige White Horizontal FE Letters LDCHWFE White Horizontal Decal LDHWFE Optional Lock for G, E, W, L22, B:_________________

Gray _ Bronze ___ Silver For More Information on Options See Other Submittals: Handles & Levers Decals/Die Cuts & Wall Signs, More Alarm Information

(MC) Magnetic Catch -Replaces Roller Catch

STEP 3: SELECT DOOR GLAZING (Check one box below)

10 Clear Acrylic 15 Bronze Acrylic 17 Clear Tempered Glass

13 Wire Glass with Safety Film 16 Gray Acrylic 18 Laminated Safety Glass

The Ambassador Series is a Durable, Attractive Steel Cabinet with Powder-coat Finish that Stands up to Conditions in Commercial Buildings.

Door & Trim Construction: Cold rolled steel with white powder-coated finish standard. Flush cabinet doors with a 5/8” door stop are attached by a continuous hinge and equipped with zinc-plated handle and roller catch. All models have 1-3/4” wide trim on frame and 1-1/4 trim on doors with glazing.

Trim Style & Depth: Trimless Recessed - See Separate Submittal. Recessed Flat 3/8” Trim, Semi Recessed - 1-1/4”, 1-1/2” Square Edge or 2-1/2”, 3”, 4”, 4-1/2” Rolled Edge (4” has recessed ADAC pull). Surface-mount models have a square edge or optional rolled edge upon request.

Tub: The tub is constructed of cold rolled steel with white powder-coat finish standard.

Fire-Rated Option Available: Yes - See separate Submittal Form.

1017V10 3” Rolled Trim Semi-Recessed

STEP 2: SELECT DOOR STYLE WITH HANDLE Check one box below Examples on Page 2

F Full Glazing in 1-1/4” wide Frame L22 Solid with SAF-T-LOK™

G Full Glazing with SAF-T-LOK™ in 1-1/4” Frame L24 Sold with Cylinder Lock - No Handle

D Horizontal Duo Panel V Vertical Duo

E Horizontal Dual Panel with SAF-T-LOK™ W Vertical Duo with SAF-T-LOK™

S21 Solid Door B Solid with 2” x 4” View Window & SAF-T-LOK™

1816F10

1-1/2” Square Trim

Semi-Recessed

1012W10 4” Rolled Trim with Standard Flush Pull

BIM Objects for REVIT® Platform

SUBMITTAL: AMBASSADOR STEEL FIRE EXTINGUISHER CABINETS

TRIM & DOOR SERIES # Tub I.D. Frame O.D. Wall Opening

QTY Model Trim Style A B C E F W H D

8115 Flat 3/8” Trim ● 9 18 5 1/2 12 3/8 21 3/8 10 19 5 3/8 Cosmic & Galaxy 2 1/2-6 (6 lb must be mounted on tub wall), Mercury 2 1/2- 5

8116 1 1/2 Square ● 9 18 5 1/2 12 3/8 21 3/8 10 19 4 1/8

8117 2 1/2 Rolled ● 9 18 5 1/2 12 3/8 21 3/8 10 19 3 1/8

8113 Surf. Mtd Square 12 3/16 21 3/16 6 12 3/8 21 3/8 -- -- --

1710 2-1/4 Square ● 10 1/2 24 5 13 7/8 27 3/8 11 1/2 25 3 Cosmic/Gal/Merc 2-5

1815 Flat 3/8” Trim ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 5 3/8 Cosmic & Galaxy

2 1/2-6 (6 lb must be mounted on tub wall), Mercury 2 1/2-5

1816 1 1/2 Square ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 4 1/8

1817 3 Rolled ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 2 5/8

1812 4 Rolled/Flush Pull● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 1 7/8

1818 4 1/2 Rolled 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 1 1/8

1015 Flat 3/8” Trim ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 5 7/8

Cosmic & Galaxy 2 1/2-10

Mercury 2 1/2-5 , Sentinel 5

1016 1 1/2 Square ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 4 5/8

1017 3 Rolled ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 3 1/8

1012 4 Rolled/Flush Pull● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 2 3/8

1018 4 1/2 Rolled 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 1 5/8

1013 Surf Mtd. Square 13 11/16 27 3/16 6 1/2 13 7/8 27 3/8 -- -- --

2015 Flat 3/8” Trim ● 12 27 7 3/4 15 3/8 30 3/8 13 28 7 5/8 Any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5 & 10

2016 1 1/4 Square● 12 27 7 3/4 15 3/8 30 3/8 13 28 6 5/8

2017 2 1/2 Rolled● 12 27 7 3/4 15 3/8 30 3/8 13 28 5 3/8

2012 4 Rolled/Flush Pull● 12 27 7 3/4 15 3/8 30 3/8 13 28 4 1/8

2018 4 1/2 Rolled 12 27 7 3/4 15 3/8 30 3/8 13 28 3 3/8

2013 Surf Mtd. Square 15 3/16 30 3/16 8 1/4 15 3/8 30 3/8 -- -- --

3015 Flat 3/8” Trim ● 16 32 7 3/4 19 3/8 35 3/8 17 33 7 5/8 Any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5-15, 272

3016 1 1/4 Square● 16 32 7 3/4 19 3/8 35 3/8 17 33 6 5/8

3017 2 1/2 Rolled● 16 32 7 3/4 19 3/8 35 3/8 17 33 5 3/8

3012 4 Rolled/Flush Pull● 16 32 7 3/4 19 3/8 35 3/8 17 33 4 1/8

3018 4 1/2 Rolled 16 32 7 3/4 19 3/8 35 3/8 17 33 3 3/8

3013 Surf Mtd. Square 19 3/16 35 3/16 8 1/4 19 3/8 35 3/8 -- -- --

4015 Flat 3/8” Trim ● 20 27 7 3/4 23 3/8 30 3/8 21 28 7 5/8 Two each any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5

4016 1 1/4 Square● 20 27 7 3/4 23 3/8 30 3/8 21 28 6 5/8

4017 2 1/2 Rolled● 20 27 7 3/4 23 3/8 30 3/8 21 28 5 3/8

4012 4 Rolled/Flush Pull● 20 27 7 3/4 23 3/8 30 3/8 21 28 4 1/8

4018 4 1/2 Rolled 20 27 7 3/4 23 3/8 30 3/8 21 28 3 3/8

4013 Surf Mtd. Square 23 3/16 30 3/16 8 1/4 23 3/8 30 3/8 -- -- --

F - Full glass with pull handle G - Full glass with pull handle above Saf-T-Lok (Not Shown)

D - Horizontal duo panel with pull handle E - Horizontal duo panel with pull handle above Saf-T- Lok. (Not Shown)

V - Vertical duo panel with pull handle W - Vertical duo panel with pull handle above Saf-T- Lok. (Not Shown)

S21 - Solid with pull handle L22 - Solid with pull handle above Saf-T-Lok L24 - Solid with cylinder key lock and no handle (Not Shown)

B - Small view window with pull handle, above Saf-T- Lok

Fits Extinguishers View Submittal

3/8” Flat 3/8” 1-1/2” Square 2-1/2”, 3” 4”, 4-1/2” Rolled Surface 1Trim Trim Rolled Edge with Recessed Mt. Square Pull Standard

ADA Cabinet Mounting Height: Standard Pull on G, E, W, L22 and B Door Styles with Saf-T-Lok are 3 5/8” Higher than Door Center, so Allow for that When Mounting Cabinet.

Standard Pull with No Lock or Flush Pull are Centered on Door.

VIEW ALL DOOR STYLES ONLINE

Models shown in Large Bold above are available in several door styles for Quick Shipment. See current Stock List.

● Cabinets that Meet 4” Maximum ADA Projection Requirement ADA Information

Overview en-Vision Module

(EVM)

Signals when the extinguisher:

• Is removed from its designated location

• Loses internal pressure

• Is continuously obstructed.

Signals when the monitor-ing device loses normal operational power.

Code recognized to eliminate 30-day physical inspections

Local visual and audible indication

Powered by either battery (two 3V Lithium) or External (12-24VDC)

Normally open or closed outputs interface to any monitoring system.

Field adjustable obstruc-tion detection timing & range

Fits into a standard single-gang electrical box

Used with all types, sizes and make of portable fire extinguishers.

FEATURES

The en-Gauge en-Vision Module (EVM) is the central element of the en-Gauge fire extinguisher monitoring system.

When combined with an en-Gauge enabled pressure gauge it allows a portable fire extinguisher to become a fully supervised component of a monitored alarm system.

Operation

The EVM works in conjunction with an en-Gauge enabled fire extinguisher pressure gauge. The gauge has integral electronics providing extinguisher removal and pressure status signals to the EVM via a proprietary tether. The tether has a quick-disconnect type connector at the gauge end that is designed to break away from the extinguisher once the extin-guisher has been removed from its designated location.

The EVM detects any potential obstruction that may block access to an extinguisher by utilizing an ultrasonic transducer housed in the EVM faceplate. An obstruction has to be blocking access to the extinguisher from 15 to 30 hours (de-fault mode) before the EVM confirms the obstruction and generates an extinguisher trouble. The obstruction detection timing can be modified for specific applications using the dipswitches on the back of the EVM.

The EVM delivers the fire extinguisher status information both locally and remotely. The EVM annunciates any extinguisher status change (extinguisher alert or extinguisher trouble) locally through the use of Light Emitting Diodes (LEDs) located on the faceplate of the unit and through the use of an integral sounder.

The EVM can send an extinguisher alert or extinguisher trouble signal to other monitoring systems through the use of two form “C“ relay outputs. The first relay output is designated the extinguisher alert output. This relay will change state if an extinguisher is removed from its designated location. The second relay output is designated the extinguisher trouble output. This relay will change state if the EVM senses that the extinguisher has had a pressure loss below a safe operational level, has had an obstruction continuously blocking access, or the unit’s power source has dropped below a normal operational level. Both EVM output relays provide normally open or normally closed contacts.

The EVM can be powered via two 3 volt lithium batteries or from an external 12-24VDC power source. The EVM monitors its power source and will generate a unique trouble signal when the power level falls below a safe operating level.

Ordering Information

Model Description

F00133 EVM Externally Powered Kit (12-24VDC) F00141 EVM Battery Powered Kit (Two 3VDC Batteries)

Replacement Parts

A00084 EVM (Module Only) C00054 3V Lithium Battery C00078 Wall Grommet C00126 Wiring Terminal C00007 48” Tether

EVM Dimensional Drawing

Specifications

Battery Supply Voltage 6VDC Battery Type Two 3V Panasonic Lithium Panasonic Part # CR123A Battery Life 3 Years in normal operating conditions External Power Source Supply Voltage 12-24VDC External Power Source Supply Current Normal State 4 mA Alert State 6.5mA Output Relay Contact Rating 1 Amp @30VDC Dimensions 4.65” x 2.91” x 2.38” Obstruction Detection Range 30” (Default Setting)/18” (Optional Setting) Obstruction Detection Timing 0-15 Hours (Optional Setting) 5-20 Hours (Optional Setting) 15-30 Hours (Default Setting) 50-65 Hours (Optional Setting) Extinguisher Gauge Tether Length 48” Operating Temperature Range 32 to 120 Degrees F Shipping Weight 1 LB Warranty 1 Year Listings UL 864 en-Gauge, Inc.

11 Commerce Road | Rockland, Massachusetts 02370 info@engaugeinc.net | www.engaugeinc.net Voice: 1.888.ENGAUGE (364.2843)

DS-EVM-REV 1 PRintED 03/12 en-Gauge® is available through a network of factory trained, highly qualified, authorized distributors.

2 3 4 5 6 7 8 9 101

1) Power In +

2) Power In -

3) Power Out +

4) Power Out -

5) Alert Relay NC

6) Alert Relay C

7) Alert Relay NO

8) Trouble Relay NC

9) Trouble Relay C

10) Trouble Relay NO

WIRING TERMINAL DIAGRAM

Battery Powered Module

Externally Powered Module

Dorn VA Building 10

Columbia, SC

Engauge Fire Extinguisher Monitoring

Equipment Data Submittal

December 14, 2020

JOHNSON CONTROLS

3243 Sunset Blvd West Columbia, SC 29169

50 Technology Drive Westminster, Ma 01441-0001

(978) 731-2500

FAX: (978) 731-7856

Johnson Controls Material List (THIS IS NOT A PRICE QUOTATION)

TO:

MSS Solutions, LLC Project: Dorn VA BLDG 10 EnGauge 1001 Tuckaseegee Rd Customer Reference: EnGauge Extinguisher Monitoring PO Box 32607 Johnson Controls Reference: L40862-000155 CHARLOTTE, NC 28208-2607 Proposal #: P40862-000151

Date: 12/14/2020 Attn: Kyle Williamson Page 1 of 1

This quote reflects Federal Government/Non GSA Pricing. Johnson Controls Fire Protection LP offers

GSA pricing to GSA authorized, eligible, ordering entities. Please contact your sales representative if you have any questions.

QUANTITY MODEL NUMBER DESCRIPTION

EnGauge Equipment 15 F00170 10LB ABC Extinguisher

15 1015F10 AMB/FULL GLASS FLAT CAB

15 F00133 EVM (en-Vision Module) Kit

AMBASSADOR™ IS A TRADEMARK OF ACPG

DOWNLOAD CURRENT SUBMITTAL BEFORE ORDERING

Distributor: Quantity:

Contractor: Approved By:

Model #: Architect:

Project: Date: © 2017 Activar Construction Products Inc

HEADQUARTERS:9702 NEWTON AV S, BLOOMINGTON, MN 55431

MANUFACTURING: BLOOM NGTON MN & COMMERCE, CA ● WAREHOUSES: FT MYERS FL, ATLANTA GA, DALLAS TX, SEATTLE WA, LANCASTER PA, FARGO ND, OMAHA NE 6/13/17

SUBMITTAL: AMBASSADOR™ STEEL FIRE EXTINGUISHER CABINETS PAGE 1 OF 2

STEP 1: SELECT MODEL NUMBER AND QUANTITY ON CHART (refer to chart on page 2) A. Determine Trim Style according to wall depth.

B. Determine Tub I.D. according to size most suited for extinguisher and wall opening.

STEP 4: OPTIONAL FEATURES AT ADDED COST (SELECT ANY)

Optional Tub Color: ____ Black _____Red Black Vertical FE Letters LDCVBFE Black Vertical Decal LDVBFE (CA) Commander Alarm

Futura “Fire” Pull ____ Mill Alum _ Red ____ White Red Vertical FE Letters LDCVRFE Red Vertical Decal LDVRFE (BA) Brigadier Alarm

Flush Pull Handle White Vertical FE Letters LDCVWFE White Vertical Decal LDVWFE (SA) Strobe Alarm (Surface Mount Models)

Polished Chrome Handle (PUCH) Black Horizontal FE Letters LDCHBFE Black Horizontal Decal LDHBFE Etched/Engraved Lettering in Glass or Metal- Attach Sub.

Optional Colors: Red ___ Black ___ Flat Black Red Horizontal FE Letters LDCHRFE Red Horizontal Decal LDHRFE Rolled Edge Surface Mount- See Separate Submittal

___ Sand AMS Beige SC Flat Beige White Horizontal FE Letters LDCHWFE White Horizontal Decal LDHWFE Optional Lock for G, E, W, L22, B:_________________

Gray _ Bronze ___ Silver For More Information on Options See Other Submittals: Handles & Levers Decals/Die Cuts & Wall Signs, More Alarm Information

(MC) Magnetic Catch -Replaces Roller Catch

STEP 3: SELECT DOOR GLAZING (Check one box below)

10 Clear Acrylic 15 Bronze Acrylic 17 Clear Tempered Glass

13 Wire Glass with Safety Film 16 Gray Acrylic 18 Laminated Safety Glass

The Ambassador Series is a Durable, Attractive Steel Cabinet with Powder-coat Finish that Stands up to Conditions in Commercial Buildings.

Door & Trim Construction: Cold rolled steel with white powder-coated finish standard. Flush cabinet doors with a 5/8” door stop are attached by a continuous hinge and equipped with zinc-plated handle and roller catch. All models have 1-3/4” wide trim on frame and 1-1/4 trim on doors with glazing.

Trim Style & Depth: Trimless Recessed - See Separate Submittal. Recessed Flat 3/8” Trim, Semi Recessed - 1-1/4”, 1-1/2” Square Edge or 2-1/2”, 3”, 4”, 4-1/2” Rolled Edge (4” has recessed ADAC pull). Surface-mount models have a square edge or optional rolled edge upon request.

Tub: The tub is constructed of cold rolled steel with white powder-coat finish standard.

Fire-Rated Option Available: Yes - See separate Submittal Form.

1017V10 3” Rolled Trim Semi-Recessed

STEP 2: SELECT DOOR STYLE WITH HANDLE Check one box below Examples on Page 2

F Full Glazing in 1-1/4” wide Frame L22 Solid with SAF-T-LOK™

G Full Glazing with SAF-T-LOK™ in 1-1/4” Frame L24 Sold with Cylinder Lock - No Handle

D Horizontal Duo Panel V Vertical Duo

E Horizontal Dual Panel with SAF-T-LOK™ W Vertical Duo with SAF-T-LOK™

S21 Solid Door B Solid with 2” x 4” View Window & SAF-T-LOK™

1816F10

1-1/2” Square Trim

Semi-Recessed

1012W10 4” Rolled Trim with Standard Flush Pull

BIM Objects for REVIT® Platform

SUBMITTAL: AMBASSADOR STEEL FIRE EXTINGUISHER CABINETS

TRIM & DOOR SERIES # Tub I.D. Frame O.D. Wall Opening

QTY Model Trim Style A B C E F W H D

8115 Flat 3/8” Trim ● 9 18 5 1/2 12 3/8 21 3/8 10 19 5 3/8 Cosmic & Galaxy 2 1/2-6 (6 lb must be mounted on tub wall), Mercury 2 1/2- 5

8116 1 1/2 Square ● 9 18 5 1/2 12 3/8 21 3/8 10 19 4 1/8

8117 2 1/2 Rolled ● 9 18 5 1/2 12 3/8 21 3/8 10 19 3 1/8

8113 Surf. Mtd Square 12 3/16 21 3/16 6 12 3/8 21 3/8 -- -- --

1710 2-1/4 Square ● 10 1/2 24 5 13 7/8 27 3/8 11 1/2 25 3 Cosmic/Gal/Merc 2-5

1815 Flat 3/8” Trim ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 5 3/8 Cosmic & Galaxy

2 1/2-6 (6 lb must be mounted on tub wall), Mercury 2 1/2-5

1816 1 1/2 Square ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 4 1/8

1817 3 Rolled ● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 2 5/8

1812 4 Rolled/Flush Pull● 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 1 7/8

1818 4 1/2 Rolled 10 1/2 24 5 1/2 13 7/8 27 3/8 11 1/2 25 1 1/8

1015 Flat 3/8” Trim ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 5 7/8

Cosmic & Galaxy 2 1/2-10

Mercury 2 1/2-5 , Sentinel 5

1016 1 1/2 Square ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 4 5/8

1017 3 Rolled ● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 3 1/8

1012 4 Rolled/Flush Pull● 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 2 3/8

1018 4 1/2 Rolled 10 1/2 24 6 13 7/8 27 3/8 11 1/2 25 1 5/8

1013 Surf Mtd. Square 13 11/16 27 3/16 6 1/2 13 7/8 27 3/8 -- -- --

2015 Flat 3/8” Trim ● 12 27 7 3/4 15 3/8 30 3/8 13 28 7 5/8 Any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5 & 10

2016 1 1/4 Square● 12 27 7 3/4 15 3/8 30 3/8 13 28 6 5/8

2017 2 1/2 Rolled● 12 27 7 3/4 15 3/8 30 3/8 13 28 5 3/8

2012 4 Rolled/Flush Pull● 12 27 7 3/4 15 3/8 30 3/8 13 28 4 1/8

2018 4 1/2 Rolled 12 27 7 3/4 15 3/8 30 3/8 13 28 3 3/8

2013 Surf Mtd. Square 15 3/16 30 3/16 8 1/4 15 3/8 30 3/8 -- -- --

3015 Flat 3/8” Trim ● 16 32 7 3/4 19 3/8 35 3/8 17 33 7 5/8 Any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5-15, 272

3016 1 1/4 Square● 16 32 7 3/4 19 3/8 35 3/8 17 33 6 5/8

3017 2 1/2 Rolled● 16 32 7 3/4 19 3/8 35 3/8 17 33 5 3/8

3012 4 Rolled/Flush Pull● 16 32 7 3/4 19 3/8 35 3/8 17 33 4 1/8

3018 4 1/2 Rolled 16 32 7 3/4 19 3/8 35 3/8 17 33 3 3/8

3013 Surf Mtd. Square 19 3/16 35 3/16 8 1/4 19 3/8 35 3/8 -- -- --

4015 Flat 3/8” Trim ● 20 27 7 3/4 23 3/8 30 3/8 21 28 7 5/8 Two each any Cosmic, Galaxy (20 lb must be mounted on cabinet tub), Mercury, Saturn or Grenadier P, Sentinel 5

4016 1 1/4 Square● 20 27 7 3/4 23 3/8 30 3/8 21 28 6 5/8

4017 2 1/2 Rolled● 20 27 7 3/4 23 3/8 30 3/8 21 28 5 3/8

4012 4 Rolled/Flush Pull● 20 27 7 3/4 23 3/8 30 3/8 21 28 4 1/8

4018 4 1/2 Rolled 20 27 7 3/4 23 3/8 30 3/8 21 28 3 3/8

4013 Surf Mtd. Square 23 3/16 30 3/16 8 1/4 23 3/8 30 3/8 -- -- --

F - Full glass with pull handle G - Full glass with pull handle above Saf-T-Lok (Not Shown)

D - Horizontal duo panel with pull handle E - Horizontal duo panel with pull handle above Saf-T- Lok. (Not Shown)

V - Vertical duo panel with pull handle W - Vertical duo panel with pull handle above Saf-T- Lok. (Not Shown)

S21 - Solid with pull handle L22 - Solid with pull handle above Saf-T-Lok L24 - Solid with cylinder key lock and no handle (Not Shown)

B - Small view window with pull handle, above Saf-T- Lok

Fits Extinguishers View Submittal

3/8” Flat 3/8” 1-1/2” Square 2-1/2”, 3” 4”, 4-1/2” Rolled Surface 1Trim Trim Rolled Edge with Recessed Mt. Square Pull Standard

ADA Cabinet Mounting Height: Standard Pull on G, E, W, L22 and B Door Styles with Saf-T-Lok are 3 5/8” Higher than Door Center, so Allow for that When Mounting Cabinet.

Standard Pull with No Lock or Flush Pull are Centered on Door.

VIEW ALL DOOR STYLES ONLINE

Models shown in Large Bold above are available in several door styles for Quick Shipment. See current Stock List.

● Cabinets that Meet 4” Maximum ADA Projection Requirement ADA Information

Overview en-Vision Module

(EVM)

Signals when the extinguisher:

• Is removed from its designated location

• Loses internal pressure

• Is continuously obstructed.

Signals when the monitor-ing device loses normal operational power.

Code recognized to eliminate 30-day physical inspections

Local visual and audible indication

Powered by either battery (two 3V Lithium) or External (12-24VDC)

Normally open or closed outputs interface to any monitoring system.

Field adjustable obstruc-tion detection timing & range

Fits into a standard single-gang electrical box

Used with all types, sizes and make of portable fire extinguishers.

FEATURES

The en-Gauge en-Vision Module (EVM) is the central element of the en-Gauge fire extinguisher monitoring system.

When combined with an en-Gauge enabled pressure gauge it allows a portable fire extinguisher to become a fully supervised component of a monitored alarm system.

Operation

The EVM works in conjunction with an en-Gauge enabled fire extinguisher pressure gauge. The gauge has integral electronics providing extinguisher removal and pressure status signals to the EVM via a proprietary tether. The tether has a quick-disconnect type connector at the gauge end that is designed to break away from the extinguisher once the extin-guisher has been removed from its designated location.

The EVM detects any potential obstruction that may block access to an extinguisher by utilizing an ultrasonic transducer housed in the EVM faceplate. An obstruction has to be blocking access to the extinguisher from 15 to 30 hours (de-fault mode) before the EVM confirms the obstruction and generates an extinguisher trouble. The obstruction detection timing can be modified for specific applications using the dipswitches on the back of the EVM.

The EVM delivers the fire extinguisher status information both locally and remotely. The EVM annunciates any extinguisher status change (extinguisher alert or extinguisher trouble) locally through the use of Light Emitting Diodes (LEDs) located on the faceplate of the unit and through the use of an integral sounder.

The EVM can send an extinguisher alert or extinguisher trouble signal to other monitoring systems through the use of two form “C“ relay outputs. The first relay output is designated the extinguisher alert output. This relay will change state if an extinguisher is removed from its designated location. The second relay output is designated the extinguisher trouble output. This relay will change state if the EVM senses that the extinguisher has had a pressure loss below a safe operational level, has had an obstruction continuously blocking access, or the unit’s power source has dropped below a normal operational level. Both EVM output relays provide normally open or normally closed contacts.

The EVM can be powered via two 3 volt lithium batteries or from an external 12-24VDC power source. The EVM monitors its power source and will generate a unique trouble signal when the power level falls below a safe operating level.

Ordering Information

Model Description

F00133 EVM Externally Powered Kit (12-24VDC) F00141 EVM Battery Powered Kit (Two 3VDC Batteries)

Replacement Parts

A00084 EVM (Module Only) C00054 3V Lithium Battery C00078 Wall Grommet C00126 Wiring Terminal C00007 48” Tether

EVM Dimensional Drawing

Specifications

Battery Supply Voltage 6VDC Battery Type Two 3V Panasonic Lithium Panasonic Part # CR123A Battery Life 3 Years in normal operating conditions External Power Source Supply Voltage 12-24VDC External Power Source Supply Current Normal State 4 mA Alert State 6.5mA Output Relay Contact Rating 1 Amp @30VDC Dimensions 4.65” x 2.91” x 2.38” Obstruction Detection Range 30” (Default Setting)/18” (Optional Setting) Obstruction Detection Timing 0-15 Hours (Optional Setting) 5-20 Hours (Optional Setting) 15-30 Hours (Default Setting) 50-65 Hours (Optional Setting) Extinguisher Gauge Tether Length 48” Operating Temperature Range 32 to 120 Degrees F Shipping Weight 1 LB Warranty 1 Year Listings UL 864 en-Gauge, Inc.

11 Commerce Road | Rockland, Massachusetts 02370 info@engaugeinc.net | www.engaugeinc.net Voice: 1.888.ENGAUGE (364.2843)

DS-EVM-REV 1 PRintED 03/12 en-Gauge® is available through a network of factory trained, highly qualified, authorized distributors.

2 3 4 5 6 7 8 9 101

1) Power In +

2) Power In -

3) Power Out +

4) Power Out -

5) Alert Relay NC

6) Alert Relay C

7) Alert Relay NO

8) Trouble Relay NC

9) Trouble Relay C

10) Trouble Relay NO

WIRING TERMINAL DIAGRAM

Battery Powered Module

Externally Powered Module

DN-6857:C2 • 6/19/2012 — Page 1 of 6

CAB-4 Series Cabinets ONYX® Series Backboxes with Locking Doors

Peripheral Devices

DN-6857:C2 • G-190

co v.

jp g

NFS2-3030 and DVC in “C” sized CAB-4 cabinet

General All cabinets for NOTIFIER fire alarm control panels are fabri-cated from 16-gauge steel. The cabinet assembly consists of two basic parts: a backbox and a locking door. Cabinets are available in either black or red, with or without windows. The window model provides a tasteful combination to accent the decor of the finest lobby setting.

• The key-locked door is provided with a pin-type hinge, two keys and the necessary hardware to mount the door to the backbox.

• The backbox has been engineered to provide ease-of-entry for the installer. Knockouts are positioned at numer-ous points to aid the installer in bringing a conduit into the enclosure with a minimum of hardship.

• Right- or left-hand hinges, selectable in the field. Door opens 180°.

• Cabinets are arranged in four standard sizes, A (one tier) through D (four tiers), plus a mini cabinet (AA, one tier without a battery compartment). See Ordering Information.

• A trim ring option is available for semi-flush mounting.

• Chassis bridge available for assembling multiple CHS-4 chassis external to the backbox.

• Certified for seismic applications when used with the appro-priate seismic mounting kit.

Ordering Information A complete cabinet assembly consists of: a door, a backbox, an optional battery plate, and an optional semi-flush trim ring.

For each cabinet required, order one “DR” door and one “SBB” backbox. The BP2-4 battery plate is required for each cabinet assembly that mounts batteries and/or a power supply in the lower position of the cabinet. The optional trim ring is an attractive “picture frame”-style black metal ring.

MINI “AA” SIZE, ONE TIER

DR-AA4: Door assembly, window, one tier (no battery com-partment), BLACK, 9.8 lbs.

DR-AA4R: Door assembly, window, one tier (no battery com-partment), RED, 9.8 lbs.

DR-AA4B: Door assembly, solid door, one tier (no battery compartment), BLACK.

DR-AA4BR: Door assembly, solid door, one tier (no battery compartment), RED.

SBB-AA4: Backbox assembly, one tier (no battery compart-ment), BLACK, 16.65 lbs.

SBB-AA4R: Backbox assembly, one tier (no battery compart-ment), RED, 16.65 lbs.

TR-AA4: Accessory semi-flush-mount trim ring, one tier (no battery compartment).

NOTE: Black trim rings are used with red or black cabinets.

ONE TIER, “A” SIZE

DR-A4: Door assembly, window, one tier, BLACK, 14.20 lbs.

DR-A4R: Door assembly, window, one tier, RED, 14.20 lbs.

DR-A4B: Door assembly, solid door, one tier, BLACK, 14.30 lbs.

DR-A4BR: Door assembly, solid door, one tier, RED, 15 lbs.

SBB-A4: Backbox assembly, one tier, BLACK, 21 lbs.

SBB-A4R: Backbox assembly, one tier, RED, 21 lbs.

TR-A4: Accessory semi-flush-mount trim ring, one tier (open-ing 24.062" [61.118 cm] W x 20.062" [50.958 cm] H), BLACK,

2.5 lbs.

NOTE: Black trim rings are used with red or black cabinets.

BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox, 3.10 lbs.

TWO TIERS, “B” SIZE

DR-B4: Door assembly, window, two tiers, BLACK, 17.45 lbs.

DR-B4R: Door assembly, window, two tiers, RED, 17.45 lbs.

ADDR-B4: Two-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. BLACK.

ADDR-B4R: Two-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. RED.

DR-B4B: Door assembly, solid door, two tiers, BLACK, 18.80 lbs.

DR-B4BR: Door assembly, solid door, two tiers, RED, 18.80 lbs.

SBB-B4: Backbox assembly, two tiers, BLACK, 26.88 lbs.

SBB-B4R: Backbox assembly, two tiers, RED, 26.88 lbs.

TR-B4: Accessory semi-flush-mount trim ring, two tiers (open-ing 24.062" [61.118 cm] W x 28.562" [72.548 cm] H), BLACK, 3 lbs.

NOTE: Black trim rings are used with red or black cabinets.

BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox, 3.10 lbs.

Page 2 of 6 — DN-6857:C2 • 6/19/2012

THREE TIERS, “C” SIZE

DR-C4: Door assembly, window, three tiers, BLACK, 20.75 lbs.

DR-C4R: Door assembly, window, three tiers, RED, 20.75 lbs.

ADDR-C4: Three-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. BLACK.

ADDR-C4R: Three-tier-sized door designed for use with a CA- 2 chassis mounted in the top rows. RED.

DR-C4B: Door assembly, solid door, three tiers, BLACK, 23.45 lbs.

DR-C4BR: Door assembly, solid door, three tiers, RED, 23.45 lbs.

SBB-C4: Backbox assembly, three tiers, BLACK, 32.60 lbs.

SBB-C4R: Backbox assembly, three tiers, RED, 32.60 lbs.

TR-C4: Accessory semi-flush-mount trim ring, three tiers (opening 24.062" [61.118 cm] W x 37.187" [94.455 cm] H), BLACK, 3.50 lbs.

NOTE: Black trim rings are used with red or black cabinets.

BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox, 3.10 lbs.

FOUR TIERS, “D” SIZE

DR-D4: Door assembly, window, four tiers, BLACK, 23.95 lbs.

DR-D4R: Door assembly, window, four tiers, RED, 23.95 lbs.

ADDR-D4: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. BLACK.

ADDR-D4R: Four-tier-sized door designed for use with a CA-2 chassis mounted in the top rows. RED.

DR-D4B: Door assembly, solid door, four tiers, BLACK, 28.40 lbs.

DR-D4BR: Door assembly, solid door, four tiers, RED, 28.40 lbs.

SBB-D4: Backbox assembly, four tiers, BLACK, 40 lbs.

SBB-D4R: Backbox assembly, four tiers, RED, 40 lbs.

TR-D4: Accessory semi-flush-mount trim ring, four tiers (open-ing 24.062" [61.118 cm] W x 45.812" [116.363 cm] H), BLACK,

3.80 lbs.

NOTE: Black trim rings are used with red or black cabinets.

BP2-4: Battery plate. Used to cover battery and power supply when lower position is used in backbox, 3.10 lbs.

ACCESSORIES

ADP-4B: Annunciator dress panel.

CAB-BM: For use with “B” sized cabinets in Marine applica-tions. See DN-60688 for more information.

CB-1: Chassis bridge. Provides a bridge between CHS Series chassis.

DP-1B: Blank dress panel, covers one CAB-4 tier, BLACK.

SEISKIT-CAB: Seismic mounting kit. Required for seismic-certified applications with NFS2-3030, NFS2-640, and NFS- 320SYS. Includes battery bracket for two 26 AH batteries.

VP-2B: Ventilator panel.

WC-2: Wire channel. Provides a pair of wire trays to neatly route wiring between CHS chassis.

Agency Listings and Approvals These listings and approvals below apply to the CAB-4 Series Cabinets. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.

• UL Listed: S635

• ULC Listed: S635

• MEA: 317-01-E, 345-02-E

• CSFM: 7165-0028:0243 (NFS2-640), 7165-0028:0224

(NFS2-3030)

• FM approved

• FDNY: COA# 6085, COA# 6098

CAB-4 Series cabinets with SEISKIT-CAB comply with seismic requirements of IBC 2000, IBC 2003, IBC 2006, IBC2009, and

CBC 2007.

DN-6857:C2 • 6/19/2012 — Page 3 of 6

“A” SIZE

CABINET

Knockouts on top of cabinets.

ko .w m f

Cabinet Dimensions and Features cab-a4-2003.wmf

Keyhole dimensions

CAB4keyhole.wmf

Height of mounting bolt after installation

Page 4 of 6 — DN-6857:C2 • 6/19/2012

“AA” SIZE

CABINET

“B” SIZE

CABINET

cab-b4-2003.wmf cab-b4-2003.wmf

“C” SIZE

CABINET

cab-c4-2003.wmf

DN-6857:C2 • 6/19/2012 — Page 5 of 6

“D” SIZE

CABINET

cab-d4-2003.wmf

“D” sized cabinet with solid door.

Solid door option available on all sizes in black or red.

d4 b.

w m f

The BP2-4 Battery Plate covers the Main Power Supply and the batteries in the cabinet.

Only one BP2-4 is required per cabinet unless an AA cabinet is used (no battery compartment).

bp 4.

w m f

Page 6 of 6 — DN-6857:C2 • 6/19/2012

ONYX® and NOTIFIER® are registered trademarks of Honeywell International Inc.

©2012 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited.

This document is not intended to be used for installation purposes.

We try to keep our product information up-to-date and accurate.

We cannot cover all specific applications or anticipate all requirements.

All specifications are subject to change without notice.

For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118.

www.notifier.com

Made in the U.S. A.

DN-7111:M • 3/24/17 — Page 1 of 8

NFS2-640(E)

Intelligent Addressable Fire Alarm System

Intelligent Fire Alarm Control Panels

DN-7111:M • A-13

NFS2-640

N F

S 2-

0-

D V

C _r ig ht

.jp g

General The NFS2-640 intelligent Fire Alarm Control Panel is part of the ONYX® Series of Fire Alarm Controls from NOTIFIER.

In stand-alone or network configurations, ONYX Series products meet virtually every application requirement.

The NFS2-640’s modular design makes system planning easier.

The panel can be configured with just a few devices for small build-ing applications, or networked with many devices to protect a large campus or a high-rise office block. Simply add additional periph-eral equipment to suit the application.

A host of other options are available, including single- or multi-channel voice; firefighter’s telephone; LED, LCD, or PC-based graphic annunciators; networking; advanced detection products for challenging environments; wireless fire protection; and many addi-tional options.

NOTE: Unless called out with a version-specific “E” at the end of the part number, “NFS2-640” refers to models NFS2-640 and NFS2-640E; similarly, “CPU2-640” refers to models CPU2-640 and CPU2-640E.

Features

• Certified for seismic applications when used with the appropri-ate seismic mounting kit.

• Approved for Marine applications when used with listed com-patible equipment. See DN-60688.

• One, expandable to two, isolated intelligent Signaling Line Cir-cuit (SLC) Style 4, 6 or 7.

• Wireless fire protection using SWIFT Smart Wireless Integrated

Fire Technology. See DN-60820.

• Up to 159 detectors and 159 modules per SLC; 318 devices per loop/636 per FACP or network node.

– Detectors can be any mix of ion, photo, thermal, or multi-sen-sor; wireless detectors are available for use with the FWSG.

– Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG.

• Standard 80-character display, 640-character large display (NCA-2), or display-less (a node on a network).

• Network options:

– High-speed network for up to 200 nodes (NFS2-3030, NFS2-

640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX-

Works, NFS-3030, NFS-640, and NCA).

– Standard network for up to 103 nodes (NFS2-3030, NFS2-

640, NFS-320(C), NFS-320SYS, NCA-2, DVC-EM, ONYX-

Works, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP-300/ 400, AFP-1010, and AM2020). Up to 54 nodes when DVC- EM is used in network paging.

• 6.0 A switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sen-sor, Wheelock, or Gentex strobe synchronization.

• Built-in Alarm, Trouble, Security, and Supervisory relays.

• VeriFire® Tools online or offline programming utility. Upload/

Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware.

• Autoprogramming and Walk Test reports.

• Multiple central station communication options:

– Standard UDACT

– Internet

– Internet/GSM

• 80-character remote annunciators (up to 32).

• EIA-485 annunciators, including custom graphics.

• Printer interface (80-column and 40-column printers).

• History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file.

• Alarm Verification selection per point, with automatic counter.

• Presignal/Positive Alarm Sequence (PAS).

• Silence inhibit and Auto Silence timer options.

• March time/temporal/California two-stage coding/strobe syn-chronization.

• Field-programmable on panel or on PC, with VeriFire Tools pro-gram check, compare, simulate.

• Full QWERTY keypad.

• Battery charger supports 18 – 200 AH batteries.

• Non-alarm points for lower priority functions.

• Remote ACK/Signal Silence/System Reset/Drill via monitor modules.

• Automatic time control functions, with holiday exceptions.

• Surface Mount Technology (SMT) electronics.

• Extensive, built-in transient protection.

• Powerful Boolean logic equations.

• Support for SCS Series smoke control system in HVAC mode.

NCA-2 AS PRIMARY DISPLAY

• Backlit, 640-character display.

• Supports SCS Series smoke control system in FSCS mode when SCS is connected to the NCA-2 used as primary display.

• Supports DVC digital audio loop.

• Printer and CRT EIA-232 ports.

• EIA-485 annunciator and terminal mode ports.

• Alarm, Trouble, Supervisory, and Security relays.

Page 2 of 8 — DN-7111:M • 3/24/17

FLASHSCAN® INTELLIGENT FEATURES

• Polls up to 318 devices in less than two seconds.

• Activates up to 159 outputs in less than five seconds.

• Multicolor LEDs blink device address during Walk Test.

• Fully digital, high-precision protocol (U.S. Patent 5,539,389).

• Manual sensitivity adjustment — up to nine levels.

• Pre-alarm ONYX intelligent sensing — up to nine levels.

• Day/Night automatic sensitivity adjustment.

• Sensitivity windows:

– Ion – 0.5 to 2.5%/foot obscuration.

– Photo – 0.5 to 2.35%/foot obscuration.

– Laser (VIEW®) – 0.02 to 2.0%/foot obscuration.

– Acclimate Plus™ – 0.5 to 4.0%/foot obscuration.

– IntelliQuad™ – 1.0 to 4.0%/foot obscuration.

– IntelliQuad™ PLUS – 1.0 to 4.0%/foot obscuration

• Drift compensation (U.S. Patent 5,764,142).

• Degraded mode — in the unlikely event that the CPU2-640 microprocessor fails, FlashScan detectors revert to degraded operation and can activate the CPU2-640 NAC circuits and alarm relay. Each of the four built-in panel circuits includes a Disable/Enable switch for this feature.

• Multi-detector algorithm involves nearby detectors in alarm decision (U.S. Patent 5,627,515).

• Automatic detector sensitivity testing (NFPA-72 compliant).

• Maintenance alert (two levels).

• Self-optimizing pre-alarm.

FSL-751 (VERY INTELLIGENT EARLY WARNING)

SMOKE DETECTION TECHNOLOGY

• Advanced ONYX intelligent sensing algorithms differentiate between smoke and non-smoke signals (U.S. Patent 5,831,524).

• Addressable operation pinpoints the fire location.

• Early warning performance comparable to the best aspiration systems at a fraction of the lifetime cost.

FAPT-851 ACCLIMATE PLUS

LOW-PROFILE INTELLIGENT MULTI-SENSOR

• Detector automatically adjusts sensitivity levels without opera-tor intervention or programming. Sensitivity increases with heat.

• Microprocessor-based technology; combination photo and ther-mal technology.

• Low-temperature warning signal at 40°F ± 5°F (4.44°C ± 2.77°C).

FSC-851 INTELLIQUAD

ADVANCED MULTI-CRITERIA DETECTOR

• Detects all four major elements of a fire (smoke, heat, CO, and flame).

• Automatic drift compensation of smoke sensor and CO cell.

• High nuisance-alarm immunity.

INTELLIGENT FAAST® DETECTORS FSA-5000, FSA-8000, FSA-

20000 AND FSA-20000P

• Connects directly to the SLC loop of compatible ONYX series panels.

• Provides five event thresholds that can be individually pro-grammed with descriptive labels for control-by-event program-ming; uses five detector addresses.

• Uses patented particle separator and field-replaceable filter to remove contaminants.

• Advanced algorithms reject common nuisance conditions

• FSA-5000 covers 5,000 square feet through one pipe.

• FSA-8000 covers 8,000 square feet through one pipe.

• FSA-20000 covers 28,800 square feet through one to four pipes.

Sample System Options

7111blok-2014.wmf

SLC Intelligent Loop 1

DEVICES

FSC-851 IntelliQuad FAPT-851 Acclimate PLUS FSL-751 FlashScan VIEW

FSP-851 Photo FSI-851 Ion

FST-851 Thermal

FSA-8000

...etc.

NBG-12LX

FMM-1

IDC

FDU-80

LCD2-80

Up to 32 remote displays

EIA-485

EIA-485

EIA-232

2048 annunciator/control points

Optional 636-point UDACT

Dual phone lines to Central Station

ACM/AEM-24AT

LED Annunciator

LDM-32

Custom Graphics

ACM-8R

Relay Control

FCM-1

NAC

FRM-1

Relay Contact

SLC Intelligent Loop 2

KDM-R2 display

OR

NCA-2

OR

with no display

PRN Series Printer

NFS2-640

“C” cabinet size shown

FWSG

XP6/10 I/O Modules

DN-7111:M • 3/24/17 — Page 3 of 8

• FSA-20000P covers 28,800 square feet through one to four pipes. Supports addressable pipes to pinpoint location of alarm events

FCO-851 INTELLIQUAD™ PLUS

ADVANCED MULTI-CRITERIA FIRE/CO DETECTOR

• Detects all four major elements of a fire.

• Separate signal for life-safety CO detection.

• Optional addressable sounder base for Temp-3 (fire) or Temp-4

(CO) tone.

• Automatic drift compensation of smoke sensor and CO cell.

• High nuisance-alarm immunity.

SWIFT WIRELESS

• Self-healing mesh wireless protocol.

• Each SWIFT Gateway supports up to 50 devices: 1 wireless gateway and up to 49 SWIFT devices.

• Up to 4 wireless gateways can be installed with overlapping network coverage.

RELEASING FEATURES

• Ten independent hazards.

• Sophisticated cross-zone (three options).

• Delay timer and Discharge timers (adjustable).

• Abort (four options).

• Low-pressure CO2 listed.

DIGITAL VOICE AND TELEPHONE FEATURES

• Up to eight channels of digital audio.

• 35, 50, 75, and 100/125 watt digital amplifiers (DAA2/DAX series and DS series; NCA-2 required as primary display).

• Solid-state digital message generation.

• Firefighter telephone option.

• 30- to 120-watt high-efficiency amplifiers (AA Series).

• Backup tone generator and amplifier option.

• NFS2-640 can also integrate with the FirstCommand Emer-gency Communications System. See DN-60772.

HIGH-EFFICIENCY OFFLINE SWITCHING

3.0 A POWER SUPPLY (6.0 A IN ALARM)

• 120 VAC (NFS2-640); 240 VAC (NFS2-640E).

• Displays battery current/voltage on panel (with display).

FlashScan, Exclusive World-Leading Detector Protocol At the heart of the NFS2-640 is a set of detection devices and device protocol — FlashScan (U.S. Patent 5,539,389). FlashScan is an all-digital protocol that gives superior precision and high noise immunity.

In addition to providing quick identification of an active input device, this protocol can also activate many output devices in a fraction of the time required by competitive protocols. This high speed also allows the NFS2-640 to have the largest device per loop capacity in the industry — 318 points — yet every input and output device is sampled in less than two seconds. The micropro-cessor-based FlashScan detectors have bicolor LEDs that can be coded to provide diagnostic information, such as device address during Walk Test.

ONYX Intelligent Sensing Intelligent sensing is a set of software algorithms that provides the NFS2-640 with industry-leading smoke detection capability. These complex algorithms require many calculations on each reading of each detector, and are made possible by the high-speed micro-computer used by the NFS2-640.

Drift Compensation and Smoothing: Drift compensation allows the detector to retain its original ability to detect actual smoke, and resist false alarms, even as dirt accumulates. It reduces mainte-nance requirements by allowing the system to automatically per-form the periodic sensitivity measurements required by NFPA 72.

Smoothing filters are also provided by software to remove tran-sient noise signals, such as those caused by electrical interfer-ence.

Maintenance Warnings: When the drift compensation performed for a detector reaches a certain level, the performance of the detector may be compromised, and special warnings are given.

There are three warning levels: (1) Low Chamber value; (2) Main-tenance Alert, indicative of dust accumulation that is near but below the allowed limit; (3) Maintenance Urgent, indicative of dust accumulation above the allowed limit.

Sensitivity Adjust: Nine sensitivity levels are provided for alarm detection. These levels can be set manually, or can change auto-matically between day and night. Nine levels of pre-alarm sensitiv-ity can also be selected, based on predetermined levels of alarm.

Pre-alarm operation can be latching or self-restoring, and can be used to activate special control functions.

Self-Optimizing Pre-Alarm: Each detector may be set for “Self- Optimizing” pre-alarm. In this special mode, the detector “learns” its normal environment, measuring the peak analog readings over a long period of time, and setting the pre-alarm level just above these normal peaks.

Cooperating Multi-Detector Sensing: A patented feature of ONYX intelligent sensing is the ability of a smoke sensor to con-sider readings from nearby sensors in making alarm or pre-alarm decisions.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .