The solicitation is for the construction of a new 15,000 gross square foot optometric facility at the William Jennings Bryan Dorn VA Medical Center in Columbia, SC. The project will address the needs of VA patients and employees with a building tailored to the functional and operational requirements of the Optometry and Ophthalmology departments. Key work includes new construction, HVAC, utilities, interior finishes, site work, storm water detention, and communication utilities in an active hospital environment. The solicitation is being issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ww
Seismic Cable Bracing System
• Mechanical
• Electrical
• Telecommunications
• Plumbing
• Ductwork
• Fire Protection
• Pneumatic Tubing
• Suspended Equipment
• Floor/Roof-Mounted Equipment
• Architectural Features
• Furniture/File Cabinets/Shelving
• Lab & Sensitive Equipment
• Retrofit
• Raised-Access Floors
Introducing...
Loos & Co.’s Engineers’ Tools offers a comprehensive solution to streamline all of your seismic bracing project designs. Our user-friendly, web-based Design Calculator is capable of quickly completing the complex calculations required to create code-compliant seismic bracing designs.
The Engineers’ Tools Seismic Calculator will process all of the complex NFPA-13 seismic calculations from your designs, alert you if anything is incorrect, and then produce a completed NFPA-13 form to submit to the Authority Having Jurisdiction (AHJ). If your project conditions change, the calculator allows you to easily edit your design.
It will then produce a Bill of Materials for easy quoting through your Loos Distributor.
Now available for FREE, online at:
www.loosseismicbracing.com
Use in conjunction with our free Seismic Design Guide, also avail-able on our website. This helpful guide provides detailed product cut sheets, installation instruc-tions, and other useful information to complete your seismic bracing projects.
Loos & Co.’s Seismic Cable Bracing is ideally suited to cost-effectively satisfy new codes and standards provisions on earthquake resistance of architectural, mechanical and electrical components and systems.
APPLICATIONS
Industry Leader In Cost-Effective Codes and Standards Compliance Solutions
UNIQUE FEATURES
ESL-1007
ESL-1004
The ORIGINAL since 1993
Loos & Co’s Seismic Cable Bracing assemblies are:
• Pre-Stretched, Color-Coded, Easy-to-Install
• Break Strength Certified. Third-party tested/listed to verify that cable assemblies, including fittings, maintain cable nominal breaking strength.
• Uses swaged end fittings as required by 2012 IBC per ASCE 19-10, which does not permit wedge and clip-type fittings.
• Third-Party Listed for use in complying with NFPA-
13, the International Building Code (IBC), the ASCE
19 and the ASCE 7, including:
-UL listed (9P62) since 1996
-ICC-ES listed (ESL-1004 & ESL-1007)
-Intertek (C#: 720066)
• Listed by FBC for system compatibility with
Lubrizol CPVC pipe.
• Made in the U.S.A.
4.25.19
9P62
DISTRIBUTED BY
901 Industrial Boulevard, Naples, FL 34104 Phone: 239-648-5667 / Fax: 239-643-4558
Email: info@loosseismicbracing.com www. loosseismicbracing.com
Appendix P
P/N: #GO3-CBL
250 Ft. Spool
Load Rating: 600 Lbs.
P/N: #OR4-CBL
250 Ft. Spool
Load Rating: 1100 Lbs.
P/N: #GR6-CBL
250 Ft. Spool
Load Rating: 2800 Lbs.
C7 Length: 7.5” Weight: 9.5 oz.
Use: Cut size #3 (Gold) and #4 (oranGe) cable with one hand.
C9 Length: 13” Weight: 1.5 Lbs.
Use: Two-handed tool, cuts For Size #3 (Gold), #4 (oranGe) and #6 (Green).
#0-3-SBHS
Length: 12’’ Use: For Size #3 (Gold) only
#3-346-SB
Length: 26” Use: Two-handed tool for sizes #3 (Gold), #4 (Orange) and #6 (Green).
HC-5010-SB
Length: 22’’ Use: For Size #3 (Gold), #4 (oranGe), #6 (Green) and #8 (Black).
HC-3010-SB
Length: 21’’ Use: For Size #3 (Gold), #4 (oranGe) and #6 (Green).
The FELCO C7 and C9 Precision Cable Cutters are ideal for cutting and trimming excess cable.
Products
#GO3-SLV #OR4-SLV
#GR6-SLV #BL8-SLV
Crimping of the oval sleeves for these braces requires the use of the correct tool and gauging in order to maintain brace strengths and to speed installation.
Handswaging Tools:
Cable Cutters:
Sway Bracing Kits:
All Sizes
Battery-Powered Swaging Tools:
Pass Fail Gauge
Oval Sleeve
P/N: SAFR-__
Seismic Anchoring
Fitting, Retrofit
P/N: SAF-__
Seismic Anchoring
Fitting
P/N: #BL8-CBL
250 Ft. Spool
Load Rating: 4600 Lbs.
Bulk Spools:
Mounting Hardware:
Pre-manufactured cable kits for 2-way or 4-way designs with a permanently-attached stake eye at one end, and a zinc-plated oval sleeve to swage onto the opposite end.
You select your cable size, bolt hole size, length, and then you’re ready to install!
P/N: SAF2-__
Seismic Anchoring
Fitting, 2 Cable Holes
P/N: SAF2R-__
Seismic Anchoring Fitting, Retrofit, 2 Cable Holes
P/N: LPF-__
Low-Pry Fitting
Concrete Anchors
79 EatonB-Line series Fire Protection Solutions
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
C o n c re te A n c h o rs
Features:
• Fully threaded, torque-controlled, wedge anchor which is designed for consistent performance in cracked and uncracked concrete.
• For use in concrete, structural sand lightweight concrete, and concrete over metal deck.
• Nominal drill bit size is the same as the anchor diameter.
• ICC-ES listed, ESR-2502, Category 1
• Zinc plated carbon steel body with stainless steel expansion clip from premium performance.
• Qualified for seismic and wind loading.
Approvals: Included in our Seismic Engineering Guidelines approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to our Seismic Engineering Guidelines, OPM-0052-13.
ICC-ES Certified. See ICC-ESR-2502 UL (Underwriters Laboratories) Listed FM (Factory Mutual) Approved
Refer to pages 11-20 through 11-23 in Seismic Engineering Guidelines OPM-0052-13 for approval OSHPD structural attachment data.
AWSD Series - Power Stud+®† SD2 Seismic Wedge Anchors
Anchor Size Wedge Anchor Diameter Length Thread Length Wt./100 Part No. in. (mm) in. (mm) in. (mm) Lbs. (kg)
AWSD-37-300 3/8” (9.5) 3” (76.2) 13/4” (44.4) 11.4 (5.2)
AWSD-37-350 3/8” (9.5) 31/2” (88.9) 21/4” (57.1) 12.2 (5.5)
AWSD-37-375 3/8” (9.5) 33/4” (95.2) 21/2” (63.5) 13.2 (6.0)
AWSD-37-500 3/8” (9.5) 5” (127.0) 33/4” (95.2) 16.0 (7.2)
AWSD-50-375 1/2” (12.7) 33/4” (95.2) 21/8” (54.0) 23.0 (10.4)
AWSD-50-450 1/2” (12.7) 41/2” (114.3) 27/8” (73.0) 26.6 (12.0)
AWSD-50-550 1/2” (12.7) 51/2” (139.7) 37/8” (98.4) 34.0 (15.4)
AWSD-50-700 1/2” (12.7) 7” (177.8) 53/8” (136.5) 38.0 (17.2)
AWSD-62-475 5/8” (15.9) 43/4” (120.6) 27/8” (73.0) 50.3 (22.8)
AWSD-62-500 5/8” (15.9) 5” (127.0) 31/8” (79.4) 52.0 (23.6)
AWSD-62-600 5/8” (15.9) 6” (152.4) 41/8” (104.8) 58.8 (26.7)
AWSD-62-700 5/8” (15.9) 7” (177.8) 51/8” (130.2) 65.2 (29.6)
AWSD-75-550 3/4” (19.0) 51/2” (139.7) 31/4” (82.5) 81.5 (36.9)
AWSD-75-625 3/4” (19.0) 61/4” (158.7) 4” (101.6) 94.0 (42.6)
AWSD-75-700 3/4” (19.0) 7” (177.8) 43/4” (120.6) 106.5 (48.3)
For loading information, refer to the ICC-ES ESR-2502 evaluation report.
Seismic Wedge Anchor - Data 3/8”-16 1/2”-13 5/8”-11 3/4”-10
ANSI Drill Bit Size (in. - mm) 3/8” - (9.5mm) 1/2” - (12.7mm) 5/8” - (15.9mm) 3/4” - (19.0mm)
Fixture Clearance Hole (in. - mm) 7/16” - (11.1mm) 9/16” - (14.3mm) 11/16” - (17.5mm) 13/16” - (20.6mm)
Minimum Hole Depth (in. - mm) 25/8” - (66.7mm) 23/4” - (69.8mm) 41/4” - (107.9mm) 5” - (127.0mm)
Minimum Concrete Thickness (in. - mm) 4” - (101.6mm) 41/2” - (114.3mm) 53/4” - (146.0mm) 7” - (177.8mm)
Max. Tightening Torque (lbs-ft - N•m) 20 lbs-ft - (27.1N•m) 40 lbs-ft - (54.2N•m) 60 lbs-ft - (81.3N•m) 110 lbs-ft - (149.1N•m)
Min. Embedment Depth (in. - mm) 23/8” - (60.3mm) 21/2” - (63.5mm) 37/8” - (98.4mm) 41/2” - (114.3mm)
OPM
† Power Stud+® SD2 is a registered trademark used by DeWalt.
FEB 2018 GFV-574 PAGE 1 of 1
AUXILIARY DRAIN BALL VALVE
GENERAL DESCRIPTION
The Auxiliary Drain Ball valve with labeled sleeve is utilized for a low point auxiliary drain valve or for drum drip connections for dry pipe systems.
It is manufactured with 1” Male NPT inlet x Female NPT outlet. It is shipped with a 1” brass plug con-veniently Teflon taped and made-in to the outlet.
The 1” Male NPT inlet eliminates the need to make-in an additional pipe nipple into the low point piping.
The valve body is brass with a chrome plated brass ball and teflon seat. The handle sleeve is red gloss PVC with white “Aux. Drain” lettering.
4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com
4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com
Technical Support • 989-414-2600 • techservice@globesprinkler.com
FIGURE 1: MATERIALS OF CONSTRUCTION
FIGURE 2: DRUM DRIP INSTALLATION
GLOBE® PRODUCT WARRANTY
Globe agrees to repair or replace any of its manufactured products found to be defective in material or workmanship for a period of one year from date of shipment.
For specific details of our warranty please refer to Price List Terms and Conditions of Sale (Our Price List).
TECHNICAL DATA
• Factory Tested to 300 psi (20.6 bar)
• Male x Female NPT (with Plug)
• Contains Lead – Not intended for potable water systems Materials of Construction See Figure 1
ORDERING INFORMATION
SPECIFY:
• MODEL • SIZE • PN
MODEL AD Auxiliary Drain
PART NUMBER
ITEM NO. DESCRIPTION MATERIAL
1 BODY Brass (C37700)
2 BONNET Brass (C37700)
3 SEAL Teflon (PTFE)
4 BALL Brass (C37700)
5 STEM Brass (HPb59-1)
6 PACKING Teflon (PTFE)
7 PACKING NUT Brass (C37700)
8 LEVER Steel (Q235A)
9 PLUG Brass (C37700)
10 NUT Steel (Q235A)
R
IPS CARBON STEEL PIPE – FIRE PROTECTION VALVES
VICTAULIC
IS AN ISO 9001 CERTIFIED COMPANY
® REGISTERED TRADEMARK OF VICTAULIC – © COPYRIGHT 2004 VICTAULIC – PRINTED IN U.S.A. 2466 REV D
10.18
Victaulic Company of America • Phone: 1-800-PICK-VIC (1-800-742-5842) • Fax: 610-250-8817 • e-mail:pickvic@victaulic.com Victaulic Company of Canada • Phone: 905-884-7444 • Fax: 905-884-9774 • e-mail: viccanada@victaulic.com Victaulic Europe • Phone:32-9-381-1500 • Fax: 32-9-380-4438 • e-mail: viceuro@victaulic.be Victaulic America Latina • Phone: 610-559-3300 • Fax: 610-559-3608 • e-mail: vical@victaulic.com Victaulic Asia Pacific • Phone: 65-6235-3035 • Fax: 65-6235-0535 • e-mail: vicap@victaulic.com
Series 705W FireLock
Butterfly Valve with weatherproof actuator for 300 psi service
PRODUCT DESCRIPTION
The Series 705W butterfly valve features a weatherproof actuator housing approved for indoor or outdoor use. It has a ductile iron body and disc with EPDM disc coating. The body is coated with a heat fused polyphenylene sulfide blend to meet FM requirements and the new coating requirements for the 5th edition of UL-1091. For fire protection services, Series 705W valve is UL Listed and FM Approved for 300 psi (2065 kPa) service. Flow performance exceeds UL Specification 1091 and FM Approval Standard 1112.
Weatherproof Actuator
Supervisory switches that monitor the valve in the fully open position for valves are available 2
- 12" (73,0 - 323,9 mm) pre-wired (PW).
Supply-side Tap
Series 705W valves are available with a
" NPT supply side tap designed to allow direct water supply connection to Victaulic FireLock actuated fire protection valves. See separate drawings below. This is an optional feature and must be clearly noted on all orders. Contact Victaulic for additional information on tapped valves
21/2 - 6" Sizes
8 - 12" Sizes See Victaulic publication 10.01 for details.
DIMENSIONS
Valve Size Dimensions – Inches/millimeters
Aprx.
Wgt. Ea.
Lbs./kg
Nominal Diameter
Inches\mm
Actual Out. Dia.
Inches/mm E to E
A Hgt.
B C D E F G H J K L O M N P
2.875 3.77 9.80 1.80 3.92 – 2.88 6.97 5.45 7.02 0.97 2.31 4.50 1.44 0.60 1.03 9.1
65 73,0 96 249 46 100 – 73 177 138 178 25 59 114 37 15 26 4,1
76,1 mm 3.000 3.77 9.80 1.80 3.92 – 2.88 6.97 5.45 7.02 0.97 2.31 4.50 1.50 0.60 1.03 9.1
76,1 96 249 46 100 – 73 177 138 178 25 59 114 38 15 26 4,1
3 3.500 3.77 10.48 2.14 4.22 0.08 3.50 7.61 5.45 7.33 0.97 2.31 4.50 1.75 0.00* 0.80 9.8
80 88,9 96 266 54 107 2 89 193 138 186 25 59 114 45 0 20 4,4
4 4.500 4.63 11.89 2.71 5.09 0.07 6.01 9.05 5.45 8.59 0.97 2.79 4.50 2.60 0.73 1.22 15.3
100 114,3 118 302 69 129 2 153 230 138 218 25 71 114 66 19 31 6,9
139,7 mm 5.500 5.88 12.82 3.12 5.61 0.43 6.01 9.98 5.45 8.59 0.97 3.92 4.50 – – – 20.0
139,7 149 326 79 143 11 153 253 138 218 25 100 114 – – – 9,1
5 5.563 5.88 12.82 3.12 5.61 0.43 6.01 9.98 5.45 8.59 0.97 3.92 4.50 – – – 20.0
125 141,3 149 326 79 143 11 153 253 138 218 25 100 114 – – – 9,1
165,1 mm 6.500 5.88 13.74 3.61 6.06 1.00 7.20 10.92 5.45 9.05 0.97 3.96 4.50 3.25 1.25 1.50 25.0
165,1 149 349 92 154 25 183 277 138 230 25 101 114 83 32 38 11,3
6 6.625 5.88 13.74 3.61 6.06 1.00 7.20 10.92 5.45 9.05 0.97 3.96 4.50 3.32 1.25 1.50 25.0
150 168,3 149 349 92 154 25 183 277 138 230 25 101 114 84 32 38 11,3
8 8.625 5.33 16.92 4.88 7.94 1.27 10.20 14.06 8.28 13.30 2.05 2.66 6.00 5.10 0.18 0.91 52.0
200 219,1 135 430 124 202 32 259 357 210 338 52 68 152 130 5 23 23,6
Table continued on page 2. See notes on page 2.
F
B
G D
C
J H
O Dia.
K
E
A L
¹⁄₄" NPT
Supply Tap
M A
N
P
Series 705W Series 705W with Tap
2 Series 705W FireLock
MATERIAL SPECIFICATIONS
Body:
Ductile iron conforming to ASTM A-536, coated with polyphenylene sulfide blend.
Disc:
Ductile iron conforming to ASTM A-536, various grades, EPDM coated.
Disc Coating:
Grade “E” EPDM
EPDM (Green color code). Temperature range –30°F to +230°F (–34°C to +110°C). Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL classified in accordance with ANSI/NSF 61 for cold +86°F (+30°C) and hot +180°F (+82°C) potable water service. NOT RECOMMENDED FOR PETROLEUM SERVICES.
Stem Bearings:
Teflon impregnated fiberglass with stainless steel backing.
Stem Bearing Nuts:
Type 416 Stainless Steel.
Tap Plug:
Carbon steel, plated.
O-Ring:
EPDM
Bracket:
Carbon steel, painted.
Actuator:
- 6" (65 - 150 mm): Bronze traveling nut on a steel lead screw, in a steel housing.
8 - 12" (200 - 300 mm): Steel worm and cast iron quadrant gear, in a cast iron housing.
10 ‡ 10.750 6.40 19.14 5.84 8.69 1.72 12.20 15.77 10.09 16.19 2.05 3.20 9.00 – – – 80.0
250 273.0 163 486 148 221 44 310 400 256 411 52 81 229 – – – 36,3
12 ‡ 12.750 6.50 21.54 7.04 10.00 2.66 14.25 18.28 10.09 17.22 2.05 3.25 9.00 – – – 102.0
300 323,9 165 547 179 254 68 362 464 256 437 52 83 229 – – – 46,3
* On centerline. ‡ Contact Victaulic Company of Canada for ULC Listings.
1. To prevent rotation of valves, it is recommended that Series 705W be installed with Victaulic Style 07 Zero-Flex
, Style 005 FireLock or Style HP-70 Rigid Couplings. If Victaulic flexible couplings are used, additional support may be required.
2. Valve must not be installed with disc in full open position. Disc must be partly closed so that no part is protruding beyond end of valve body.
3. Victaulic grooved end butterfly valves are permitted for use with grooved end pipe (IPS) only. Not permitted for use with plain end (IPS) pipe.
4. Series 705W valves are designed for ambient weather conditions as opposed to submersible service.
Valve Size Dimensions – Inches/millimeters
Aprx.
Wgt. Ea.
Lbs./kg
Nominal Diameter
Inches\mm
Actual Out. Dia.
Inches/mm E to E
A Hgt.
B C D E F G H J K L O M N P
F
B
G D
C
J H
O Dia.
K
E
A L
¹⁄₄" NPT
Supply Tap
M A
N
P
Series 705W Series 705W with Tap
Series 705W FireLock
Butterfly Valve 3
PERFORMANCE
The chart expresses the frictional resistance of Victaulic Series 705W in equivalent feet/meters of straight pipe.
V
Values values for flow of water at +60°F (+16°C) with a fully open valve are shown in the table below. For additional details contact Victaulic.
Formulas for CV Values:
Valve Size
Equiv.
Feet/m of Pipe
Valve Size
Equiv.
Feet/m of Pipe
Nominal Diameter
Inches/mm
Actual Outside Diameter
Inches/mm
Nominal Diameter
Inches/mm
Actual Outside Diameter
Inches/mm
2.875 5 165,1 mm 6.500 8
65 73,0 1,6 165,1 2,5
76,1 mm 3.000 5 6 6.625 8
76,1 1,6 150 168,3 2,5
3 3.500 5 8 8.625 11
80 88,9 1,6 200 219,1 3,4
4 4.500 12 10 10.750 12
100 114,3 3,7 250 273 3,7
139,7 mm 5.500 12 12 12.750 14
139,7 3,7 300 323,9 4,3
5 5.563 12
125 141,3 3,7
(Full Open)
Nominal Diameter
Inches/mm
Actual Outside Diameter
Inches/mm
Nominal Diameter
Inches/mm
Actual Outside Diameter
Inches/mm
Nominal Diameter
Inches/mm
Actual Outside Diameter
Inches/mm
2.875 325 139,7 mm 5.500 1150 8 8.625 3400
65 73,0 139,7 200 219,1
76,1 mm 3.000 325 5 5.563 1150 10 10.750 5750
76,1 125 141,3 250 273
3 3.500 482 165,1 mm 6.500 1850 12 12.750 8300
80 88,9 165,1 300 323,9
4 4.500
6 6.625
100 114,3 150 168,3
P∆ Q2
CV
Q CV ∆P×=
Where:
Q = Flow (GPM) CV = Flow Coefficient
∆P = Pressure Drop (PSI)
4 Series 705W FireLock
SWITCH AND WIRING
Supervisory Switch
- 12" (65 - 300 mm) sizes: Series 705W PW –
Two, single pole, double throw, pre-wired switches.
Switches are rated 10A @ 125 or 250 VAC 60 Hz and 0.25A @ 250 VDC, 0.50A @ 125 VDC, 2.6A @ 24 VDC
Supervisory Switch Wiring
A. Pre-wired Switches
(1) Switches Supervise Open Valve
(2) One switch has two #18 MTW wires per terminal. Permits complete supervision of leads (see diagrams below). Second switch has one #18MTW wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations such as an indicating light and an audible alarm in the area at the valve installation.
Switch #1 S1 Switch #2 S2
Normally Closed:(2) Blue Normally Open: (2) Brown Common: (2) Yellow
Normally Closed:
Blue with Stripe Normally Open:
Brown with Stripe Common:
Yellow with Stripe
(3) A ground lead, #14MTW is provided (green)
NOTE:
Connecting to Common Terminals (Yellow S1 and Yellow with Orange Stripe - S2), and Normally Closed Terminals (Blue S1 and Blue with Orange Stripe - S2); e.g., indicator light and alarm stays on until valve is fully opened; then indicator light and alarm go out.
Cap off unused wire, e.g., Brown and Brown with Orange Stripe.
Actuator Repair
In the unlikely event of an actuator failure, complete actuation replacement is required.
ALL REPLACEMENT PARTS MUST BE OBTAINED FROM THE MANUFACTURER TO ASSURE PROPER
OPERATION OF THE VALVE.
All actuators are supplied with a
" NPT outlet for conduit connection. Care must be taken to ensure water does not enter the actuator through this outlet prior to installation. Water entering the actuator will cause switch malfunctions.
This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions.
Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
{S1
{S2
CONDUIT
1/2" NPT
CONDUIT CONNECTORS
UL LISTED
JUNCTION BOX
WIRE NUTS
FIRE ALARM
CONTROL PANEL
SUPERVISORY
CIRCUIT
N.C. NO. COM.
TO END-OF-LINE RESISTO
OR NEXT INDICATOR
BELL
OR
HORNVOLTAGE SOURCE
Switch 1: 2 leads per terminal Switch 2: 1 lead per terminal
SWITCH
CONTACT RATING:
10A AT 125 AND
250VAC,
0.5A AT 125 VDC,
0.25 AT 250 VDC
S1
S2
FEATURES The low differential, unique latch and actuator design of the valve allows the valve to be reset without opening the valve. The low differential design is not subject to water columns.
The valve allows the water to operate a water motor alarm and/or electric pressure alarms, which continue until the flow of water stops.
With the optional accelerator, the valve can be configured to respond faster for use in larger systems, or where faster response times are required.
The valve is rated to 300 psi/2065 kPa water working pressure and is factory tested hydrostatically to
600 psi/4135 kPa for sizes 1 ½ – 8"/40 – 200 mm. Required air pressure is 13 psi/90 kPa.
The Series 768 is available grooved x grooved. Standard grooved dimensions conform to ANSI/
AWWA C606.
The Victaulic Series 768 FireLock NXT Dry Valve is made of high-strength, low-weight ductile iron, and it offers easy access to all internal parts. All internal parts are replaceable. Maintenance and service can be performed without removing the valve from its installed position. The rubber clapper seal is replaced easily without removing the clapper from the valve. The valve is painted inside and out to increase corrosion resistance.
The body is tapped for main drain and all available trim configurations.
Installation Options
The Victaulic Series 768 FireLock NXT Dry Valve is available bare, or in the following configurations:
Pre-trimmed
The pre-trimmed valve comes completely assembled with all necessary trim components.
Vic-Quick Riser
The Vic-Quick Riser comes completely pre-trimmed and includes a shut off valve (uses a Series
705W FireLock Butterfly valve – request publication 10.18; for 1 ½ and 2"/40 and 50 mm sizes, the
Vic-Quick Riser comes with a Series 728 Ball Valve – request publication 10.17) for system shut off, pre-set pressure switches, and a drain kit for ease of installation. For complete Vic-Quick Riser information request publication 30.20.
Series 745 FireLock Fire-Pac (Available in North America only)
The Fire-Pac is a completely pre-assembled fire protection valve that provides maximum service in a minimal enclosed space. The unit includes a water supply shutoff valve, the sprinkler system fire protection valve, alarm line pressure switches, air supervisory pressure switches, supervisory pump switches, and digital pressure gauges that are easily viewed through a window in the cabinet door.
For complete Fire-Pac information request publication 30.23.
Optional accessories ship separately.
Clapper Seal
Latch Clapper
Diaphragm Assembly
Seat
The patent-pending Victaulic Series 768 FireLock NXT Dry Valve is a low differential, latched clapper valve that uses a unique direct acting diaphragm to separate system water supplies from dry-pipe sprinkler systems.
Exaggerated for clarity
Note: Valve is shown in the “set” position
30.80_1
FireLock NXT™
Dry Valve
SERIES 768
30.80FIRE PROTECTION PRODUCTS – DEVICES
JOB/OWNER CONTRACTOR ENGINEER
System No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________
Location ____________________________ Date ________________________________ Approved ___________________________
Date ________________________________ www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
PATENT PENDING
REV_D
SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS
THE 4-INCH/114.3-MM CONFIGURATION IS SHOWN BELOW
1 ½ – 2-INCH/48.3 – 60.3-MM CONFIGURATIONS CONTAIN ¾ -INCH/19-MM DRAIN VALVES.
2 ½ – 3-INCH/73.0 – 88.9-MM CONFIGURATIONS CONTAIN 1 ¼ -INCH/31-MM DRAIN VALVES.
4 – 8-INCH/114.3 – 219.1-MM CONFIGURATIONS CONTAIN 2-INCH/50-MM DRAIN VALVES.
C - YELLOW W/STRIPE
NO - BROWN W/ STRIPE
NC - BLUE W/STRIPE
SWITCH No. 2
C - (2) YELLOW
NO - (2) BROWN
FOR INDOOR OR OUTDOOR USE
NC - (2) BLUE
SWITCH No. 1
R
A
J
*A1
B
*B1
G
F
D *D1
C Full Open
K
*E1
E
H
Size Dimensions – inches/mm Aprx. Weight Ea.
lbs/kg
Nominal Size inches mm
Actual Outside
Diameter inches mm A A1 B B1 C D D1 E E1 F G H J K
Without Trim
With Trim
1 ½ 1.900 9.00 16.43 27.25 39.50 13.75 16.00
5.25 8.50 9.50 21.25 3.04 9.17 6.98 16.7 43.0 40 48.3 228.60 417.32 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.6 19.5
2 2.375 9.00 16.43 27.25 39.50 13.75 16.00
5.25 8.50 9.50 21.25 3.04 9.17 6.98 17.0 43.0 50 60.3 228.60 417.32 692 1003 349 406 133 215 241 539 77.21 232.91 177.29 7.7 19.5
2 ½ 2.875 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 65 73.0 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5
76.1 mm
3.000 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0
76.1 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5
3 3.500 12.61 16.50 32.25 44.25 13.50 16.00 17.50 5.25 9.00 9.25 21.25 3.90 10.50 6.93 41.0 65.0 80 88.9 320.29 419.10 819 1123 342 406 444 133 228 234 539 99.06 266.70 176.02 18.7 29.5
4 4.500 15.03 19.78 33.50 45.50 15.00 15.75 20.50 5.25 9.00 10.75 21.00 6.25 9.62 8.46 59.0 95.0 100 114.3 381.76 502.41 850 1155 381 400 520 133 228 273 533 158.75 244.34 214.88 26.7 43.0
165.1 mm
6.500 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0
165.1 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6
6 6.625 16.00 22.00 34.00 46.00 15.50 17.00 22.00 5.25 8.50 11.50 20.50 6.20 9.62 8.84 80.0 116.0 150 168.3 406.40 558.80 863 1168 393 431 558 133 215 292 520 157.48 244.34 224.53 36.2 52.6
8 8.625 17.50 22.94 33.50 45.50 16.75 20.00 25.25 6.25 8.75 12.75 18.50 6.05 9.40 10.21 122.0 158.0 200 219.1 444.50 582.67 850 1155 425 508 641 158 222 323 469 153.67 238.76 259.33 55.3 71.6
NOTES:
The “A” dimension coupling is not shown in order to clarify dimensional callouts.
Components shown as dotted lines denote optional equipment.
* Measurements denoted with an asterisk take optional equipment into account.
Optional drain connection kit is shown for reference and takeout dimensions.
30.80_2
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
REV_D
PERFORMANCE Hydraulic Friction Loss
The chart below expresses the flow of water at 65ºF/18ºC through a full open valve.
P R
E S
S U
R E
D R
O P
P
S I
FLOW RATE – GPM
800 3,000 8,000
6.0 5.0 4.0
3.0
2.0
1.0 0.9 0.8 0.7 0.6 0.5 0.4
0.3
0.2
0.1 10 20 30 40 60 80 100 200 300 400 600 1,000 2,000 4,000 6,000 10,000 20,000
3" /8
0m m
4" /1 m m
6" /1 m m a nd
.1 m m
8" /2 m m
2½ "/6
5m m a nd
6.
1m m
1½ "/4
0m m
2" /5
0m m
Frictional Resistance
The chart below expresses the frictional resistance of Victaulic Series 768 FireLock NXT
Dry Valve in equivalent feet of straight pipe.
Size Equivalent Length of Pipe
Nominal Size
Inches mm
Actual Outside Dia.
Inches mm
Feet meters
1 ½ 1.900 3.00 40 48.3 0.914
2 2.375 9.00 50 60.3 2.743
2 ½ 2.875 8.00 65 73.0 2.438
76.1 mm
3.000 8.00
76.1 2.439
3 3.500 17.00 80 88.9 5.182
4 4.500 21.00 100 114.3 6.401
165.1 mm
6.500 22.00
165.1 6.706
6 6.625 22.00 150 168.3 6.706
8 8.625 50.00 200 219.1 15.240
30.80_3
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
Cv VALUES Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below.
Formulas for Cv values:
Size
Nominal Size
Inches mm
Actual Outside Dia.
Inches mm
Cv/Kv
(Fully Open Valve)
1 ½ 1.900 60 40 48.3 52.0
2 2.375 110 50 60.3 95.0
2 ½ 2.875 180 65 73.0 156.0
76.1 mm
3.000 180
76.1 156.0
3 3.500 200 80 88.9 173.0
4 4.500 350 100 114.3 302.8
165.1 mm
6.500 1000
165.1 865.0
6 6.625 1000 150 168.3 865.0
8 8.625 1500 200 219.1 1499.1
ΔP = Q2
C v
Where:
Q = Flow (GPM)
ΔP = Pressure Drop (psi)
C v = Flow CoefficientQ = C v x ΔP
ΔP = Q2
C v
Where:
Q = Flow (GPM)
ΔP = Pressure Drop (psi)
C v = Flow CoefficientQ = C v x ΔP
OPERATION The Series 768 Dry Valve contains a clapper, which has a replaceable rubber seal. The clapper makes contact with the valve’s seat ring, which has access holes leading into an intermediate cham-ber in the valve. The diaphragm contacts the latch, and the latch holds the clapper closed.
In the closed position, the valve diaphragm is maintained in the extended position by the water sup-ply pressure from upstream of the water supply control valve. The diaphragm latch holds the clapper in the closed position. The Series 776 Low Pressure Actuator (LPA) maintains the water, and the system’s air pressure controls the LPA. Required air pressure is 13 psi/90 kPa. The design of the 776 actuator does not require the traditional air cushion of 10 – 20 psi/69 – 138 kPa. Excess air pressure above 13 psi/90 kPa will cause a delay in valve operation.
Once the system’s air pressure reduces to the trip point, the LPA opens and allows the water supply pressure in the diaphragm to release (i.e. an open sprinkler). This release allows the latch to move to its open position, permitting the clapper to pivot freely, thus allowing water into the system.
Water enters the intermediate chamber of the valve through the holes in the seat ring. The water flows from the intermediate chamber to the alarm line, which activates the system’s alarms. The alarms continue to sound until the flow of water stops.
When the flow of water stops, the spring-assisted valve clapper returns to the closed position. The valve acts as an alarm check valve until the system is back in service as a dry system, according to the proper procedure.
30.80_4
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
MATERIAL SPECIFICATIONS Body: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM
A-395, grade 65-45-15, is available upon special request.
Clapper: Aluminum bronze UNS-C95500
Latch: Aluminum bronze UNS-C95500
Shaft: Stainless 17-4
Clapper Seal: Peroxide cured EPDM, ASTM D2000
Bushings/Seat O-rings: Nitrile
Springs: Stainless Steel (300 Series)
Diaphragm: Peroxide cured EPDM with fabric reinforcement
Bill of Materials
1 Valve Body 12 Cover Plate
2 Clapper 13 Cover Plate Gasket
3 Clapper Seal 14 Cover Plate Bolts (Qty. 7)
4 Seal Ring 15 Latch
5 Seal Washer 16 Latch Spring
6 Seal Retaining Ring 17 Latch Spring Bushing and O-ring (Qty. 2)
7 Seal Assembly Bolt 18 Diaphragm
8 Bolt Seal 19 Diaphragm Cover Plate
9 Clapper Spring 20 Diaphragm Cover Plate Cap Screws (Qty. 8)
10 Clapper Shaft 21 Latch Shaft
11 Clapper Shaft Bushing and O-ring (Qty. 2)
9 4
Exaggerated for clarity
30.80_5
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
TRIM PACKAGES Trim Package for Vertical Installations Include:
1 Galvanized components
2 Series 776 Low-Pressure Actuator – The Series 776 Low-Pressure Actuator is pneumatically actuated and requires only 13 psi/90 kPa minimum air pressure, regardless of the system supply pressure. This actuator allows the system to operate with a low air or gas pressure of 7 psi/48 kPa.
Request submittal 30.65.
3 Air Feed Manifold
4 All Required Pipe and Fittings
5 All Standard Trim Accessories
6 All Required Gauges
Optional Trim Package for Vertical Installations:
1 Black Trim for Foam Systems – If the valve is intended for use in a foam system, black trim must be ordered, per NFPA requirements. Specify this requirement on the order.
Optional Accessories:
• Series 746-LPA Dry Accelerator – The Series 746-LPA Dry Accelerator is required when the
Series 768 Dry Valve is installed in large systems to improve response time. Request submittal
30.64.
• Series 760 Water Motor Alarm – The Series 760 Water Motor Alarm is a mechanical device that sounds when a sustained flow of water occurs (such as with an open sprinkler). Request submittal 30.32.
• Series 75B Supplemental Alarm Device – The Series 75B Supplemental Alarm Device is designed to provide a continuous alarm for systems equipped with a mechanical device.
Request submittal 30.33.
• Series 75D Water Column Kit – The Series 75D Water Column Kit is designed to minimize residual water in the riser from collecting above the clapper. Request submittal 30.34.
• Alarm Pressure Switch – Alarm Pressure Switches are designed to activate electrical alarms and control panels when a sustained flow of water occurs (such as with an open sprinkler).
• Air Supervisory Pressure Switch – Air Pressure Supervisory Switches are used to monitor low system air pressure and are factory pre-set.
• Air Supply System – The air supply system contains all components for establishing and main-taining air in the system. The compressor, low-pressure alarms, ball valves, and required trim are included in the air supply system.
• Air Compressor
• Air Dryer
• Air Maintenance Device
• Alarm Panels
• Drain Connection Kit
30.80_6
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
AIR SUPPLY REQUIREMENTS The required air pressure for Series 768 FireLock NXT Dry Valves is 13 psi/90 kPa minimum, regard-less of the system supply pressure. Air pressures should be kept below 18 psi/124 kPa, unless a
Series 746-LPA Dry Accelerator is installed. Systems with air pressures higher than 18 psi/124 kPa may require the addition of a Series 746-LPA Dry Accelerator.
If multiple Series 768 FireLock NXT Dry Valves are installed with a common air supply, isolate the systems with a spring-loaded, soft-seated ball check valve to ensure air integrity for each system.
Good practice is to include a ball valve for isolation and service of each individual system.
The engineer/system designer is responsible for sizing the compressor so that the entire system is charged to the required air pressure within 30 minutes. DO NOT oversize the compressor to provide more airflow. An oversized compressor will slow down or possibly prevent valve operation.
If the compressor fills the system too fast, it may be necessary to restrict the air supply. Restricting the air supply will ensure that air being exhausted from an open sprinkler or manual release valve is not replaced by the air supply system as fast as it is being exhausted.
COMPRESSOR SIZING
System Capacity (in gallons)
R e q u ir e d F lo w
R a te
C F
M
COMPRESSOR REQUIREMENTS
20 psi/138 kPa 13 psi/90 kPa
30.80_7
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
BASE OR RISER-MOUNTED
COMPRESSORS
For base or riser-mounted compressors, the recommended air pressure of 13 psi/90 kPa is the
“on” or “low” pressure setting for the compressor. The “off” or “high” pressure setting should be
18 psi/124 kPa.
When a base or riser-mounted air compressor supplies air to a Series 768 FireLock NXT Dry Valve, it is not necessary to install the Victaulic Series 757 Regulated Air Maintenance Trim Assembly
(AMTA). In this case, the airline of the compressor connects to the trim at the fitting where the Series
757 Regulated AMTA is normally installed (refer to the applicable trim drawing). If the compressor is not equipped with a pressure switch, the Series 757P Air Maintenance Trim Assembly with Pressure
Switch should be installed.
In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor provides the the greatest protection for systems.
When shop air or a tank-mounted air compressor is used, the Series 757 Regulated AMTA must be installed. The Series 757 Regulated AMTA provides proper air regulation from the air reservoir to the sprinkler system.
For tank-mounted air compressors, the recommended air pressure of 13 psi/90 kPa should be used as the set point for the air regulator. The “on” pressure of the compressor should be at least 5 psi/
34 kPa above the set point of the air regulator.
SHOP AIR OR TANK-MOUNTED
AIR COMPRESSORS
30.80_8
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
SERIES 757 REGULATED AIR
MAINTENANCE TRIM ASSEMBLY
Bill of Materials
1 1⁄8-inch/3.2-mm Restrictor
2 Slow Fill Ball Valve (Normally Open)
3 Air Regulator
4 Strainer (100 Mesh)
5 Spring-Loaded, Soft-Seated
Ball Check Valve
6 Fast Fill Ball Valve (Normally Closed)
SERIES 757P AIR MAINTENANCE TRIM
ASSEMBLY WITH PRESSURE SWITCH
Bill of Materials
1 1⁄8-inch/3.2-mm Restrictor
2 Pressure Switch
3 Slow Fill Ball Valve (Normally Open)
4 Fast Fill Ball Valve (Normally Closed)
5 Strainer (100 Mesh)
6 Spring-Loaded, Soft-Seated
Ball Check Valve
NOTICE
• Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series
757 Regulated AMTA
NOTICE
• Victaulic recommends a maximum of two Series 768 FireLock NXT Dry Valves per Series
757P AMTA with Pressure Switch
Exaggerated for clarity
Exaggerated for clarity
30.80_9
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
COMPRESSOR REQUIREMENTS Compressor Requirements and Settings for Series 768 FireLock NXT Dry Valves Installed with
Series 746 Dry Accelerators
Set the air regulator of the Series 757 Regulated AMTA to 13 psi/90 kPa.
THE SERIES 757P AIR MAINTENANCE TRIM ASSEMBLY WITH PRESSURE SWITCH MUST NOT
BE USED ON A SERIES 768 FIRELOCK NXT DRY VALVE INSTALLED WITH A SERIES 746-LPA
DRY ACCELERATOR.
When a Series 768 FireLock NXT Dry Valve is installed with a Series 746-LPA Dry Accelerator, the
Series 757 Regulated AMTA must be used. NOTE: The use of an air regulator with a base or riser-mounted compressor could cause short cycling, resulting in premature wear of the compressor.
In the event a compressor becomes inoperative, a properly sized tank-mounted air compressor pro-vides the greatest protection for systems installed with a Series 746-LPA Dry Accelerator. In this situ-ation, air can be supplied continuously to the sprinkler system for an extended time period. NOTE:
The Series 757 Regulated AMTA must be used with a tank-mounted air compressor that supplies air to a Series 768 FireLock NXT Dry Valve installed with a Series 746-LPA Dry Accelerator.
The air regulator of the Series 757 Regulated AMTA is a relief-type design. Any pressure in the sys-tem that is above the set point of the air regulator will be released. Therefore, charging the air regula-tor above the set point could cause premature operation of a valve installed with a Series 746-LPA
Dry Accelerator.
Settings for Air Supervisory Pressure Switches and Alarm Pressure Switches
Air supervisory pressure switches are required for dry systems and must be set according to the following instructions. NOTE: Switches for Vic-Quick Risers are pre-set at the factory.
Wire the air supervisory pressure switches to activate a low-pressure alarm signal. NOTE: In addition, the local authority having jurisdiction may require a high-pressure alarm. Contact the local authority having jurisdiction for this requirement.
Set the air supervisory pressure switches to activate at 2 – 4 psi/14 – 28 kPa below the minimum air pressure required, but not lower than 10 psi/69 kPa.
Wire the alarm pressure switch to activate a water flow alarm.
Set the alarm pressure switch to activate on a pressure rise of 4 – 8 psi/28 – 55 kPa.
Remote System Test Valve Requirements
The remote system test valve (inspector’s test connection) should contain a UL Listed and/or FM
Approved valve (normally closed), which can be opened to simulate the operation of a sprinkler.
The remote system test valve (inspector’s test connection) should be located at the most hydrauli-cally demanding location in the release system. NOTE: Multiple restrictions on the remote system test valve (inspector’s test connection) may slow the air decay rate and cause the system to respond slower than required.
The remote system test valve (inspector’s test connection) should terminate with an orifice equal to the smallest orifice in the releasing system.
The remote system test valve (inspector’s test connection) is used to ensure that water reaches the most remote part of the system within 60 seconds.
30.80_10
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
Bill of Materials
1 Series 768 FireLock NXT Dry Valve
2 FireLock Rigid Coupling (Optional)
3 Series 705W Butterfly Valve
(Optional)
4 Drain Swing Check Valve
5 Drip Cup
6 EPS10-2 Alarm Pressure Switch
(Optional)
7 Series 729 Drip Check Valve
8 Diaphragm-Charge-Line Ball Valve
(Normally Open)
9 3-in-1 Strainer/Check/Restrictor
Assembly
10 Series 760 Water Motor Alarm
(Optional)
11 Alarm Test Ball Valve
12 Diaphragm-Charge-Line Pressure
Gauge (0-300psi/0-2068kPa)
13 Series 749 Auto Drain
14 Series 746-LPA Dry Accelerator
Assembly
(Optional)
15 Series 776 Low-Pressure Actuator
16 Air Manifold
17 EPS10-2V or EPSA10-2V Supervisory
Switch (Optional)
18 System Pressure Gauge
(0-80psi/0-552kPa with Retard)
19 Water Supply Main Drain Valve -
Flow Test
20 Water Supply Pressure Gauge
(0-300psi/0-2068kPa)
21 Drain Connection Kit (Optional)
22 Gauge Valve
23 System Main Drain Valve
24 Series 748 Ball Check Valve
From Drip Cup
Note 1
To Drip Cup or Drain
To System
From System Air Feed
To Drip Cup
Water Supply
To Drain Connection Assembly or Drain
To Drip Cup or Drain
EXPLODED VIEW DRAWING –
TRIM COMPONENTS
Series 768 FireLock NXT Dry Valve
(Optional Accessories Also Shown)
Exaggerated for clarity
Optional devices include the Series 75D Water Column Device Kit and the Series 75B Supplemental
Alarm Kit.
NOTE 1: Connection point for the Series 75D Water Column Device Kit.
For installation of the Series 75B Supplemental Alarm Device, refer to the instructions supplied with the product.
30.80_11
30.80FIRE PROTECTION PRODUCTS – DEVICES
FireLock NXT™
Dry Valve
SERIES 768
www.victaulic.com
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
WARNING
• This product must be installed by an experienced, trained installer, in accordance with the instructions provided with each valve. These instructions contain important information.
Failure to follow these instructions may result in serious personal injury, property damage, or valve leakage.
If you need additional copies of this product literature or the valve installation instructions, or if you have any questions about the safe installation and use of this device, contact Victaulic Company, P.O.
Box 31, Easton, PA 18044-0031 USA, Telephone: 001-610-559-3300.
WARNING
WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details.
This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.
NOTE
30.80
FireLock NXT™
Dry Valve
SERIES 768
30.80FIRE PROTECTION PRODUCTS – DEVICES
WCAS-6PUHYA
For complete contact information, visit www.victaulic.com
30.80 4219 REV D UPDATED 1/2007
VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2007 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.
JUNE 2018 GFV-120 Page 1 of 11
GENERAL DESCRIPTION
The Globe Series “UMC” Universal Manifold Check is a first of its kind, UL Listed and FM Approved, complete floor con-trol station or shotgun riser assembly. It is pressure rated for 300 psi (20,6 bar). It provides the most compact “footprint” while delivering all of the necessary components for your floor control station as required by the NFPA Standards.
With its multiple available configurations, it allows the con-tractor to order the suitable configuration for the site spe-cific needs. The “UMC” Universal Manifold Check is more than just a traditional stand-alone manifold. It serves as a complete floor control station as well as a complete shot-gun riser assembly inclusive of Control Valve with Internal Supervisory Switch; Check Valve; Flow Switch; Test and Drain Assembly; Adjustable Pressure Relief Valve Assembly pre-piped to drain; supply gauge (4", 6" and 8") and system gauge (1 1/4" through 8"). The “UMC” Universal Manifold Check replaces the need to order individual “Riser Mani-folds” plus control valves, check valves, and relief valve kits as all of these components are integrated into the one compact design, saving space as well as the labor to con-nect these separate components. For sizes 3" and smaller, an 18" long stainless steel braided flexible hose is included with the UMC for connecting the Test and Drain valve to a drain stack. The design takes into account both “left-hand” and “right-hand” orientations. (8" version available preas-sembled in right-hand orientation only)
FLOOR CONTROL ASSEMBLY
The UMC may be utilized to meet the NFPA 13 require-ments for Floor Control Valve Assemblies where there are multistory buildings exceeding two stories in height requir-ing zoning by floor or whenever separate control and floor zoning is specified. The UMC has been engineered with space savings in mind for those commonly installed appli-cations in stairwell landings and small alcoves. All UMC assemblies include the NFPA 13 required Listed Pressure Relief Valve which is pre-piped to drain. The relief valve is preset for 175 psi and is adjustable to 310 psi for high pres-sure system conditions. In addition to the relief valve, the UMC is equipped with a Test and Drain Valve. The Test and Drain Valve contains a test orifice of K2.8 so that it may be utilized for flow testing any system with sprinklers having K- Factors of 2.8 or larger.
Note: NFPA 13 requires that a test connection providing a flow rate equal to or less than one sprinkler of a type having the smallest orifice on the system is to be provided.
A pressure gauge is provided above the check valve clapper for sizes 1¼” through 3” to meet the gauge requirement per NFPA 13 for Floor Control Assemblies. Typically the supply side gauge is not required for multistory buildings with floor control stations as a system gauge would be on the main feed/riser but all Model UMC Manifold Check Valves are equipped with a 1/4" (DN 8) port below the clapper to ac-commodate a second gauge if desired.
SHOTGUN RISER ASSEMBLY
“Shotgun Riser Assemblies” are those assemblies which are typically installed in vertical orientations on individual sys-tem Risers. The Globe “Shotgun” Riser Manifold Assembly is available in 4 inch (DN 100), 6 inch (DN 150), and 8 inch (DN 200) sizes and is equipped with a control valve; check valve; flow switch; test and drain valve with NFPA required pressure relief valve; 2 gauges (system and supply). Sizes 4 inch (DN 100), 6 inch (DN 150), and 8 inch (DN 200) are equipped with a pressure gauge on both system side and supply side of the check valve clapper.
TECHNICAL DATA
Approvals
• cULus
• FM
Maximum System Working Pressure
• 300 psi (20.6 Bar)
End Connections
• See Table A
Materials of Construction
• See Figure 1
*Multiple Patents Pending
MODEL UMC UNIVERSAL MANIFOLD
CHECK ASSEMBLY
(With or Without Control Valve) 1¼", 1½", 2", 2½", 76.1mm, 3", 4", 6", 165.1mm, 8"
MODEL UMC UNIVERSAL MANIFOLD
CHECK ASSEMBLY
GFV-120
GFV-120
4077 Airpark Dr. Standish, MI 48658 • 989-846-4583 • www.globesprinkler.com Technical Support • 989-414-2600 • techservice@globesprinkler.com
MODEL UMC UNIVERSAL MANIFOLD
CHECK ASSEMBLY
MODEL UMC UNIVERSAL MANIFOLD
CHECK ASSEMBLY
JUNE 2018 GFV-120 Page 2 of 11
FIGURE 1: MODEL UMC MANIFOLD CHECK ASSEMBLY MATERIALS OF
CONSTRUCTION
ITEM
NO. DESCRIPTION MATERIAL
1 UMC VALVE BODY DUCTILE IRON
2 RECESSED HEX PLUG STAINLESS STEEL
3 FLOW SWITCH SEE FLOW SWITCH TECHNICAL LITERATURE
4 RIGID COUPLING SEE COUPLING TECHNICAL LITERATURE
5 BUTTERFLY CONTROL VALVE
WITH INTERNAL SUPERVISORY SWITCH SEE GLOBE BUTTERFLY CONTROL VALVE TECHNICAL LITERATURE
6 PRESSURE GAUGE PLASTIC
7 THREEWAY VALVE BRONZE
8 UMC COVER PLATE DUCTILE IRON
9 BOLT STAINLESS STEEL
10 FLOW SWITCH ADAPTER DUCTILE IRON
11 MODEL UTD TEST AND DRAIN SEE GLOBE TECHNICAL DATASHEET GFV570
12 MODEL ARV ADJUSTABLE RELIEF VALVE SEE GLOBE TECHNICAL DATASHEET GFV575
13 FLOW SWITCH PLUG DUCTILE IRON
14 UMC VALVE CLAPPER STAINLESS STEEL
15 UMC VALVE CLAPPER RETAINING BOLT STAINLESS STEEL
16 UMC VALVE CLAPPER RETAINING NUT STAINLESS STEEL
17 UMV VALVE HINGE PIN STAINLESS STEEL
18 CLAPPER FACING RETAINING RING STAINLESS STEEL
19 CLAPPER FACING EDPM
20 FLOW SWITCH PLUG BOLT STAINLESS STEEL
21 CLAPPER SPRING STAINLESS STEEL
A A
B B
SECTION A-A
A
A
NOTE:
• 4" (DN100) shown as reference
• See ordering procedure for replacement part kits and Table A through G for part numbers for all sizes and configurations
• Flow switch rotated 90 degrees on 1-1/4" through 2 1/2" sizes
JUNE 2018 GFV-120 Page 3 of 11
B
A A
B
MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY
LEFT HANDED VS RIGHT HANDED
Both the shotgun riser assembly and the floor control station assembly are available as left handed or right handed assembly. The determining factor of the left handed vs right handed is the position of the Model UTD Test and Drain. While looking at the faceplate with the Model UMC valve in the vertical orientation and flow upward (shotgun riser orientation), the posi-tion of the Model UTD Test and Drain determines the "Hand" of the valve. If the Model UTD Test and Drain is connected to the port on the right side of the valve body, it is considered a right handed assembly. If the Model UTD Test and Drain is connected to the port on the left side of the Model UMC valve the assembly is considered left handed.
FIGURE 2: MODEL UMC MANIFOLD CHECK VALVE ASSEMBLY
LEFT HANDED VS RIGHT HANDED
A A
B B
1 2
A A
B B
LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLYB
4 4
3 3
2 2
A A
B
LEFT HANDED ASSEMBLY RIGHT HANDED ASSEMBLY
BUTTERFLY VALVE
FLOW SWITCHFLOW SWITCH
TEST AND DRAIN
ASSEMBLY
UMC BODY UMC BODY
FLOW SWITCH
TEST AND DRAIN
ASSEMBLY
TEST AND DRAIN
ASSEMBLYUMC BODY
BUTTERFLY VALVE
TEST AND DRAIN
ASSEMBLY
FLOW
FLOW FLOW
CONFIGURATION REPRESENTATIVE OF SIZES 3" THROUGH 8"
(8" version available preasssembled right-hand only)
CONFIGURATION REPRESENTATIVE OF SIZES 1 1/4" THROUGH 2 1/2"
MIRRORED PORTS FOR
ALTERNATE TEST AND
DRAIN LOCATIONS
MIRRORED
PORT
MIRRORED
PORT
NOTE: SUPPLY GAUGE
NOT INCLUDED ON 3"
ASSEMBLY
NOTE: SUPPLY GAUGE
NOT INCLUDED ON 3"
ASSEMBLY
JUNE 2018 GFV-120 Page 4 of 11
SIZE
ASSEMBLY
R-RIGHT
L-LEFT
CONTROL
VALVE
UMC BODY
END
CONNECTIONS
MODEL UTD
TEST AND
DRAIN SIZE
PART NUMBER
APPROXIMATE
SHIPPING
WEIGHTS
LBS. (kg)
1 1/2" R GL300T MXF THREADED 1" 317803-R-B-H 24.0 (10.9)
1 1/2" R NONE MXF THREADED 1" 317803-R-H 18.3 (8.3)
1 1/2" L GL300T MXF THREADED 1" 317803-L-B-H 24.0 (10.9)
1 1/2" L NONE MXF THREADED 1" 317803-L-H 18.3 (8.3)
1 1/2" R NONE GXG 1" 317844-R-H 18.3 (8.3)
1 1/2" L NONE GXG 1" 317844-L-H 18.3 (8.3)
SIZE
ASSEMBLY
R-RIGHT
L-LEFT
CONTROL
VALVE
UMC BODY
END
CONNECTIONS
MODEL UTD
TEST AND
DRAIN SIZE
PART NUMBER
APPROXIMATE
SHIPPING
WEIGHTS
LBS. (kg)
1 1/4" R GL300T MXF THREADED 1" 317800-R-B-H 24.0 (10.9)
1 1/4" R NONE MXF THREADED 1" 317800-R-H 19.0 (8.6)
1 1/4" L GL300T MXF THREADED 1" 317800-L-B-H 24.0 (10.9)
1 1/4" L NONE MXF THREADED 1" 317800-L-H 19.0 (8.6)
1 1/4" R NONE GXG 1" 317843-R-H 19.0 (8.6)
1 1/4" L NONE GXG 1" 317843-L-H 19.0 (8.6)
SIZE
ASSEMBLY
R-RIGHT
L-LEFT
CONTROL
VALVE
UMC BODY
END
CONNECTIONS
MODEL UTD
TEST AND
DRAIN SIZE
PART NUMBER
APPROXIMATE
SHIPPING
WE…