Attachment 16 - 2023-09-29 544-329 BID DRAWINGS_Part3.pdf
PDF 18 MB Posted
- Solicitation number
- 36C77624R0028
About this file
This document appears to be Attachment 16 - 2023-09-29 544-329 BID DRAWINGS_Part3.pdf, which is related to the federal contract opportunity for Solicitation Number 36C77624R0028 to construct a new 15,000 GSF optometric facility at the William Jennings Bryan Dorn VA Medical Center in Columbia, SC. The project will include new construction, HVAC, utility work, interior finishes, utility coordination, site work, underground storm water detention, asbestos and lead survey and abatement, and communication utility work. The Department of Veterans Affairs Technology Acquisition Center Austin is the federal agency managing this solicitation.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
COVER COLUMN
BASE WITH 3"
CONCRETE MIN.
COLUMN, SEE
PLAN FOR SIZE
SLAB JOINTS
SEE
PLAN FOR TYPE
ISOLATION JOINT
SEE PLAN FOR
FOOTING MARK
AND SCHEDULE
FOR FTG. INFO.
ISOLATION JOINT
(TYPICAL)
FINISH FLOOR, SEE
PLAN FOR
ELEVATION
SEE PLAN FOR TOP
OF FOOTING
ELEVATION
FOR COLUMN SIZE,
BASE PLATE AND
ANCHOR BOLTS,
SEE PLAN
CL
CL
M
IN
IM
UM
3" C
O V
ER
C O
L U
M N
B A
S E
P L A
T E
S
E E
P L A
N
N
O N
S H
R
IN
K G
R O
U T
C L R
CONTINUOUS
BOTTOM
REINFORCING
LAP AS REQUIRED
SEE PLAN FOR TOP
OF FOOTING ELEV.
S E
E P
L A
N
LAP SPLICE
CLASS "B"
T H
IC
K
N E
S S
F O
O T
IN
G
THICKNESS
FOOTING
C
L R
W.W.F. CONT.
FINISH FLOOR,
SEE PLAN S
E E
P L A
N
S E
E P
L A
N O
R A
R C
H D
W G
S
D E
P R
E S
S E
D S
L A
B
S L A
B T
H
IC
K N
E S
S
8" MIN.
T = SLAB THICKNESS, SEE PLAN
T = SLAB THICKNESS, SEE PLAN
CUT ALTERNATE
WIRES
PAINT WITH CURING COMPOUND
BEFORE POURING ADJACENT SLAB
FINISH FLOOR,
SEE PLAN
FINISH FLOOR,
SEE PLAN
1/2" DIA. x 3'-0" LONG SMOOTH
DOWEL AT 2'-0" O.C.
CONTROL JOINT
CONSTRUCTION JOINT
POUR (FILL WITH JOINT FILLER)
1/8" SAWED JOINT WITHIN 12 HRS. OF
T
1/
T
3/4"
T
1/ T
4" SOLID CMU
BELOW GRADE
PROPOSED GRADE
SEE CIVIL
BRICK VENEER
SEE ARCH.
8' CMU WITH #5
AT 2'-8" O.C.
DOWEL INTO FTG
LAP 2'-6" MIN.
WALL CAP
SEE ARCH
BOND BEAM W/
(2) #4 CONT.
SITE
CONCRETE
3'-8" x 1'-2" CONT. FOOTING
W/ (4) #5 CONTINUOUS AND
#5 AT 1'-0" O.C. TRANSVERSE
M
IN
.3
C L R
C L R
T.O.W. ELEVATION
SEE ARCHITECT
(10'-0" MAXIMUM
ABOVE GRADE)
#4 AT 1'-4"
O.C.
#3 DOWELS AT 1'-4" O.C.
CL
6" CFMF BY SUPPLIER
(600S162-43 AT
1'-4" O.C. MINIMUM)
GROUT SOLID
BELOW GRADE
PROPOSED GRADE
SEE CIVIL
(2) #5
CONT.
#4 AT 4'-0" O.C.
TRANSVERSE
1'-6"
10"
1'-0"
2'-6"
1'-
M
IN
1'-
3'-0"
HSS
6x6x5/16"
GROUT SOLID
BELOW GRADE
PROPOSED GRADE,
SEE CIVIL DWGS.
SEE 6/S400
FOR FOUNDATION
INFORMATION
6" CFMF STUD
AT 16" O.C.
(600S162-43 MIN.)
E
7"
TOP OF SLAB
ELEV. (+0'-0")
T.O. STEEL
ELEV. (+3'-3 1/2")
L4x3 1/2 X 1/4 (LLV)
CAST STONE
VENEER
2x2x3 1/4" x 14 GAGE CLIP
ATTACH TO C4 WITH (3)
P.A.F'S AND TO TRACK
WITH (3) #10 SCREWS
C4x5.4 AT 7'-8" O.C.
MAX.
6" CFMF
INFILL
#4 AT 1'-4"
O.C.
3/8"x6"x1'-3" EMBED PLATE WITH (4) 1/2" DIA. x 8" LONG
HEADED STUDS
#3 DOWELS AT 1'-4"
O.C.
CL
CONT. TRACK
(`14 GA. MIN.)
1'-3" 1 1_
4" 4" 4"
1 1_
3/16"
3/16"
3/16"
ELEV.
(+2'-8")
3'-0"
GROUT SOLID
BELOW GRADE
PROPOSED GRADE,
SEE CIVIL DWGS.
SEE 6/S400
FOR FOUNDATION
INFORMATION
6" CFMF STUD
AT 16" O.C.
(600S162-43 MIN.)
GRID
SOLID GROUT
CMU BELOW
GRADE
BELOW GRADE
PENETRATION
8" CONC. WALL
W/ #4 AT 1'-0" O.C.
EACH WAY
ADD (2)#4 ABOVE
AND BELOW PENETRATION
EXTEND 2'-0" MIN. BEYOND
OPENING
TOP OF SLAB
ELEV. (+0'-0")
TOP OF FTG
ELEV. (SEE PLAN)
BRICK VENEER
1'-
ADD VERTICAL BAR
EACH SIDE OF OPENING
WHERE OPENING WIDTH
EXCEEDS VERTICAL BAR
SPACING. PROVIDE BAR
EACH SIDE EQUAL TO
NUMBER OF INTERRUPTED BARS
ADD #5 HORIZONTAL
EACH FACE. ABOVE
AND BELOW EXTEND
2'-0" MINIMUM
BEYOND OPENING.
PROVIDE BAR EACH
SIDE EQUAL TO NUMBER
OF INTERRUPTED BARS
ADD #5 x 3'-6"
DIAGONAL EACH
FACE. BEND BARS
WHERE 1'-9" EXTENSION
BEYOND OPENING
CAN NOT BE ACHIEVED
PIPE
PENETRATION
TYP HORIZONTAL
REINFORCING PER
FOUNDATION WALL
DETAILS
TYP VERTICAL
REINFORCING PER
FOUNDATION WALL
DETAILS
M
IN
1'-
M
IN
2"TY
P
3'-0"
MAX
TOP OF FTG
ELEV. (SEE PLAN)
TOP OF WALL
ELEV. (-1'-4" U.N.O.)
CL
PROPOSED GRADE
SEE CIVIL
(2) #5
CONT.
#4 AT 4'-0" O.C.
TRANSVERSE
1/2"x5 1/2"x0'-11 1/4"
BASE PL. W/ (2)
1/2" x 3 1/2" EMBED
ADHESIVE ANCHORS
SECT
HSS 5x5x1/4 POST
(DEDUCT ALT. #2)
1'-6"
1'-0"
2'-6"
1'-
M
IN
1'-
3/16
SECT2
/4
1/
2 3/4" 2 3/4"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:3
P
M
S400
TYPICAL FOUNDATION DETAILS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
3/4" = 1'-0"S400
1 TYP. TUBE COLUMN FOOTING
3/4" = 1'-0"S400
2 TYP. FOOTING STEP
3/4" = 1'-0"S400
3 TYP. DEPRESSED SLAB ON GRADE
3/4" = 1'-0"S400
4 TYP. S.O.G. C/J DETAILS
3/4" = 1'-0"S400
5 TYPICAL SCREEN WALL
3/4" = 1'-0"S400
6 TYPICAL EXTERIOR FNDN DETAIL
3/4" = 1'-0"S400
7 FNDN DETAIL AT WAITING
3/4" = 1'-0"S400
8 FNDN DETAIL LOBBY WINDOW
3/4" = 1'-0"S400
9 FNDN SECTION AT DROPPED FTG
3/4" = 1'-0"S400
10 FNDN WALL PENETRATION DETAILS
3/4" = 1'-0"S400
11 FNDN SECT AT DOOR POST
05/12/2022
Revisions: Date:
ANCHOR BOLT
DIAMETER
LC
LC
ANCHOR BOLT
DIAMETER
ROW "N"
SPACING
GUSSET PLATE
(1/2" MINIMUM)
CL
CL
"N
"B"
EDGE "B"EDGE "B"
E D
G E
"N
E D
G E
"N
"B
EDGE "N"
E D
G E
"B
E D
G E
"B
GAGE "N"
G A
G E
"B
EDGE "N"
"N" W/ (6) BOLTS
"N" W/ (8 )BOLTS
"N" W/ (10) BOLTS
"N" W/ (12) BOLTS
AB-8 AB-20
1/4
AS
REQ'D
1/4
CL
LEVELING NUT
WITH WASHER
TYPICAL ANCHOR BOLT
SQUARE
WASHER SIZE
A N
C H
O R
B O
L T
E X
T E
N S
IO
N
A N
C H
O R
B O
L T
D
IA
M E
T E
R A
N C
H O
R B
O L T
D
IA
M E
T E
R
T H
IC
K
N E
S S
S Q
U A
R E
W A
S H
E R
E M
B E
D D
E P
T H
G R
O U
T T H
IC
K
N E
S S
B A
S E
P L A
T E
T H
IC
K
N E
S S
A N
C H
O R
B O
L T
E X
T E
N S
IO
N
A N
C H
O R
B O
L T
D
IA
M E
T E
R
DIAMETER
ANCHOR
BOLT
45°
COLUMN BASE PLATE SCHEDULE
12" 12" 3/4"
"N" "B" "T"
- - 1 1/2" 1 1/2" - (4) 3/4" F1554 GR 36 8" - AB-8
GAGE
"N"
GAGE
"B"
EDGE
"N"
EDGE
"B"
ROW
SPACING
ANCHOR
BOLTS
ANCHOR
BOLT
GRADE
EDBED
DEPTH
SQUARE
WASHER
ANCHOR
BOLT
DETAIL
BP-2
BP-3
BP-4
BP-5
BP-6
MARK
BP-1
PLATE SIZE
(INCHES)
14" 14" 3/4" - - 1 1/2" 1 1/2" - (4) 3/4" F1554 GR 36 8" - AB-8
15" 15" 3/4" - - 1 1/2" 1 1/2" - (4) 3/4" F1554 GR 36 8" - AB-8
14" - - - (4) 3/4" F1554 GR 36 8" - AB-8
24" 14" F1554 GR 36 -
14" 1" 2" 2"
AB-201 1/2" 2"10" 10" 2" 10" (6) 1 1/8" 12"
11 1/4" 5 1/2" 1/2" - - - (2) 1/2" F1554 GR 36 3 1/2" - SEE 11/S400- -
B
8" FNDN
WALL
10"10"
P-1 20"x20"
(8)#7 VERT HOOKED AT TOP
(8)#7 DOWELS
#3 TIES AT 12" O.C.
(3) ADDITIONAL TIES
AT 2" O.C. AT TOP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:3
P
M
S401
FOUNDATION SCHEDULE AND
DETAILSCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
3/4" = 1'-0"S401
2 BASE PLATE SCHEDULE AND DETAILS
COLUMN FOOTING SCHEDULE
QUANTITY MARK SIZE DEPTH BOTTOM BARS TOP BARS
SERVICE LOAD CAPACITY
(KIPS) REMARKS
42 3F-4.0 4'-0"x4'-0" 12" (6)#5 E.W.
2 3F-9.0 9'-0"x9'-0" 22" (9)#7 (9)#5 223
2 3F-11.0 11'-0" x 11'-0" 26" (10)#8 (10)#5 333
1 3F-26.0x6.0 26'-0"x6'-0" 24" (7)#7LW/#5@12SW (7)#5LW/#5@12SW 468
2 3F-29.0x6.0 29'-0"x6'-0" 24" (9)#7LW/#6@12SW (8)#5LW/#5@12SW 522
19 Foundation Slab 1
3/4" = 1'-0"S401
1 PIER DETAIL
ROOF DECK,
SEE PLAN
WF GIRDER, SEE
PLAN FOR SIZE
BAR JOIST, SEE
PLAN FOR SIZE
1/8" 2 1/2"
1/4"
ROOF DECK,
SEE PLAN
TOP AND BOTTOM
CHORD HORIZONTAL
BRIDGING, SEE PLAN
FOR SIZE AND
LOCATION
ROOF DECK,
SEE PLAN
CROSS BRIDGING,
SEE PLAN FOR SIZE
BAR JOIST,
SEE PLAN
END WALL BAR JOIST,
SEE PLAN
L 3x3x1/4" x JOIST
DEPTH (24" MIN.) W/
(2) 1/2" DIA. x 4 1/2"
CS HILTI KWIK
BOLT 3 W/ 3 1/4"
EMBEDMENT
3/16" 2"
TYPICAL CROSS BRIDGING
TYPICAL HORIZONTAL BRIDGING
UNIT CURB, BEAR DIRECTLY
ON ANGLE FRAMING, BY
MECHANICAL CONTRACTOR
ROOF TOP UNIT,
SEE MEP
DWGS.
BAR JOIST, SEE PLAN
PIPE HANGER,
BY CONTRACTOR
(2) L 2x2x1/4" FROM BOTTOM
CHORD PANEL POINT TO
MECHANICAL UNIT CURB
(NOT REQUIRED WHEN CURB
IS LOCATED AT TOP CHORD
PANEL POINT)
NOTE:
REMOVE EXISTING ROOFING AND
INSULATION. ATTACH CURB
DIRECTLY TO ROOF DECK.
NOTE: ALL NEW STEEL TO BE GRADE A36
MECHANICAL PIPE,
SEE MEP DRAWINGS
1 1/2" METAL ROOF DECK
L 4x4x1/4" CONTINUOUS
SUPPORT UNDER UNIT
ADD METAL STUD
BUILT-UP BOX CONT.
UNDER CURB WITH
(2) 3.5"x1.5" x16 GAGE
TRACK W/ (2) #10 TEK
SCREWS AT 6" O.C.
16 GAGE x 12" PLATE CONT.
UNDER CURB. ATTACH TO
METAL DECK WITH #10 TEK
SCREWS AT 12" O.C. EACH SIDE
3/16" 3/16"
3/16" 3/16"
L 5x3x1/4"
(LLV)
BEAM OR
BAR JOIST,
SEE PLAN
BEAM OR
BAR JOIST,
SEE PLAN
L 3x3x1/4"
3/16" 3/16"
(TYP.)
(TYP.)
3/16" 3/16"
SEE PLAN
(3'-0"x3'-0"
MAXIMUM)
SEE PLAN OPENING SEE PLAN
SEE PLAN
STEEL SUPPORT
METAL DECK
5/8" DIA. PUDDLE WELD (TYPICAL)
PLAN LEGEND
# SIDE LAPS PER SPAN
WELD PATTERN
36/5/4
36 / 3
36 / 4
36 / 5
36 / 7
TYPICAL ATTACHMENT IS 5/8" DIA. PUDDLE WELDS.
"B" DECK SHALL BE 3/8" x 1 1/4" ARC SEAM WELDS.
SIDE LAP FASTENERS ARE #10 TEK SCREWS.
PERIMETER WELDED ATTACHMENTS SHALL BE
AT 6" O.C. TYPICAL ALL EDGES.
WELD
PATTERN
24" OR 36" COVERAGE
BEAM OUT-OF-PLAN
NOT SHOWN FOR
CLARITY
SHEAR TAB
BEAM SIZE,
SEE PLAN
HSS TUBE COLUMN,
SEE PLAN
CAP PLATE OR
THROUGH PLATE TO
MATCH BEAM FLANGE
(1/2" MINIMUM)
BEAM SIZE,
SEE PLAN
CL
SEE PLAN FOR
COLUMN EXTENSION
3/4"
TC-U4A TOP AND
BOTTOM FLANGE
TC-U4a-GF
TYPICAL
1/4 45°
L3x3x1/4
W8X10
STUB
HSS
COLUMN
HSS
LINTEL
2"
1/4
3/16
3/16
T&B
FLG
9 1/2"
(2) 1/4" FULL DEPTH
STIFFENERS
2" WIDE DECK
SUPPORT PL.
THICKNESS TO
MATCH BEAM FLG
BEAM
HSS
POST
1/2" BASE PL. W/
(4) 3/4" DIA.
BOLTS
NOTE: DECK NOT SHOWN
FOR CLARITY
3/16
TYP
2 1/2"2 1/2"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:3
P
M
S500
TYPICAL FRAMING DETAILS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
3/4" = 1'-0"S500
1 JOIST BEARING @ WF GIRDER
3/4" = 1'-0"S500
2 TYP JOIST BRIDGING
3/4" = 1'-0"S500
3 MECH. EQUIP. ON JOIST
3/4" = 1'-0"S500
4 TYP ROOF OPENING
3/4" = 1'-0"S500
5 TYP DECK FASTENER DETAIL
3/4" = 1'-0"S500
6 TYP HSS MOMENT CONNECTION
3/4" = 1'-0"S500
7 LINTEL SUPPORT AT HSS COL
3/4" = 1'-0"S500
8 POST ON BEAM DETAIL
CL
JOIST SIZE,
SEE PLAN
1 1/2" METAL
ROOF DECK
L 4x4x1/4"
CONTINUOUS
6" CFMF STUD
AT 1'-4" O.C
(600S162-43 MIN.)
L5x5x5/16 LOOSE
LINTEL
VERT. DEFLECTION
CLIP
BOXED HEADER
BY SUPPLIER
AT PUNCHED
OPENINGS
1'-6"
DECK BRG.
EL. VARIES
3 1/2"
A
JOIST SIZE,
SEE PLAN
1 1/2" METAL
ROOF DECK
6" CFM STUD
AT 1'-4" O.C.
(600S162-43 MIN.)
L4x4x1/4
CONT.
DECK BRG.
EL. VARIES
VERT. DEFLECTION
CLIP
1'-4 1/2"
1'-3 1/2"
6" CFMF
BY SUPPLIER
CORNICE
FRAMING
CAST
STONE
3/8"x5"x0'-9" PL.
W/ (2) 3/4" DIA.
BOLTS
3/8" STIFF. PL CONN. W/
(2) 13/16" x 2 1/4"
SLOTTED HOLES
HSS 5x3x1/4 POST
LOCATE AT EACH
CANOPY ROD BRACE
(DEDUCT ALTERNATE #4)
HSS 6x6x1/4 W/ CONT. 5/16" x 1'-0 1/2"
BOTTOM PL.
HSS 3x3x1/4 STUB W/ 1/2"x6"x6" END PL. TYPICAL
PREFAB CANOPY
AND BRACE
(DEDUCT
ALTERNATE #4)
7"
3"
3/16
T.O.S.
VARIES
B.O. STL
(+9'-8")
T.O. PARAPET
(+22'-1 1/2")
CORNICE
FRAMING
CONT.
L4x4x1/4
DOUBLE 6" CFM STUDS
AT 1'-4" O.C. BACK TO BACK
(2-S600S200-68 MIN.)
BY SUPPLIER
CAP TRACK
FOR CONNECTION
VERTICAL DEFLECTION
CLIP EA. SIDE
1 1/2" METAL
ROOF DECK
ROOF BEAM
SEE PLAN
T.O.S.
VARIES
T.O. PARAPET
(+22'-1 1/2")
1/4 2@12
E
CAST STONE VENEER,
SEE ARCH. DRAWINGS
JOIST SIZE,
SEE PLAN
1 1/2" METAL
ROOF DECK
6" CFMF
STUD
HSS 10x6x3/8" WITH 5/16" x1'-0 1/2" BTM. PLATE
CONTINUOUS
HSS 6x6x1/4"
(DEDUCT ALTERNATE #4)
HSS 8x6x5/16" WITH 5/16" x1'-0 1/2" BTM. PLATE
CONTINUOUS (DEDUCT
ALTERNATE #4)
CORNICE
FRAMING
1'-6"
7"
DECK BRG.
EL. (+20'-6")
B.O. STEEL
ELEV. (+18'-0 1/2")
T.O. STEEL
ELEV. (+14'-7 1/2")
B.O. STEEL
ELEV. (+9'-8 1/2")
L4x3 1/2x1/4
(LLV)
3 1/2"
6" CFMF
BY SUPPLIER
(600S162-43 MIN.)
BRICK VENEER
CL
FULL DEPTH
STIFF. CONNECTION
W12
1/2" PL.
STIFFENER
HSS6x4X1/4 W/ 1/4' x 1'-0 1/2"
CONT. BOTTOM PL.
C4x5.4 HANGER
AT 5'-3" O.C. MAX
L4x4x1/4
CONT.
1'-6"
7"
B.O. STEEL
(+12'-8")
1/4 4
3/16
1/2"
9 1/2"
3 1/2"
JOIST SIZE,
SEE PLAN
1 1/2" METAL
ROOF DECK
6" CFM STUD
AT 1'-4" O.C.
(600S162-43 MIN.)
L4x4x1/4
CONT.
CONT.
9"x20 GA.
PLATE
ROOF BEAM
SEE PLAN
1 1/2" MTL
ROOF DECK
DECK BRG.
(+20'-6")
11 1/2"
10 1/2" EOJ
6" CFMF
BY SUPPLIER
3/8"x5"x0'-9" PL.
W/ (2) 3/4" DIA.
BOLTS
3/8" STIFF. PL
CONN. W/
(2) 13/16" x 2 1/4"
SLOTTED HOLES
HSS 3x3x1/4 STUB W/ 1/2"x6"x6" END PL.
TYPICAL
BRICK
VENEER
HSS 5x5x1/4 POST
LOCATE AT EACH
CANOPY ROD BRACE
(DEDUCT ALTERNATE #2)
PREFAB CANOPY
AND BRACE
(DEDUCT ALTERNATE #2)
L5x5x5/16 LOOSE
LINTEL
DOOR
7"
3/16
T.O.S.
VARIES
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:3
P
M
S501
FRAMING SECTIONS AND DETAILS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
3/4" = 1'-0"S501
1 TYP EXTERIOR ROOF SECTION
3/4" = 1'-0"S501
2 TYP EXT. ROOF LOW SIDE
3/4" = 1'-0"S501
3 SECTION AT ENTRY CANOPY
3/4" = 1'-0"S501
4 ENTRY ROOF SECTION
3/4" = 1'-0"S501
5 CLERESTORY ROOF SECTION
3/4" = 1'-0"S501
6 ROOF SECTION LOBBY WINDOW
3/4" = 1'-0"S501
7 CLERESTORY DETAIL AT GUTTER
3/4" = 1'-0"S501
8 SECTION AT DOOR CANOPY
AB
Roof 14' - 0"
FIRST
0' - 0"
22'-0"
HSS6X6X5/16 2
W14X22
H S
S
X
X
/8
H S
S
X
X
/8
Pu=+/-49k
BC
High Roof
20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
20'-0"
HSS6X6X5/16 2
W14X22
H S
S
X
X
/8
H S
S
X
X
/8
Pu=+/-43k
AB
High Roof
20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
22'-0"
HSS6X6X5/16 2
H S
S
X
X
/8
H S
S
X
X
/8
W14X22
Pu=+/-51k
7 8
Roof 14' - 0"
FIRST
0' - 0"
21'-0"
H S
S
X
X
/8
HSS6X6X5/16
H S
S
X
X
/8
W16X31
Pu=+ /-6
7k
3 4 High Roof
20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
21'-0"
HSS6X6X5/16
H S
S
X
X
/8
H S
S
X
X
/8
W16X31
Pu=+ /-6
5k
D E
High Roof 20' - 6"
Roof 14' - 0"
W10X15
13'-8"
H S
S
X
X 1/
4 HS
S
3X3X1/4 HS
S3X3X1/4
H S
S X
X
/1
W16X31
Pu = +/- 5k Pu
5k
High Roof 20' - 6"
Roof 14' - 0"
21'-0"
W12X19
HSS3X3X1/4 HSS3X3X1/4
H S
S X
X
/1
H S
S
X
X 1/
DE
High Roof 20' - 6"
Roof 14' - 0"
13'-8"
W10X15
HS
S
3X3X1/4 HS
S3X3X1/4
H S
S
X
X 1/
W16X31
Pu=+/-5K Pu=
-5 k
High Roof 20' - 6"
Roof 14' - 0"
21'-0"
W12X19
HSS3X3X1/4 HSS3X3X1/4
H S
S
X
X 1/
W14X22
H S
S X
X
/1
NOTES:
1. REFER TO PLANS AND BRACED FRAME ELEVATIONS FOR COLUMN, BEAM,
AND BRACE SIZES.
2. THE WORK POINT FOR THE INTERSECTION OF BRACES, COLUMNS, AND BEAM
MEMBERS SHALL OCCUR AT THE CENTROIDS OF THESE MEMBERS, UNLESS
NOTED OTHERWISE.
3. 'Pu' INDICATES BRACING FORCES. FORCES SHOWN ON THE BRACED FRAME
ELEVATION OR TRUSS FRAME ARE FACTORED AXIAL FORCES IN KIPS.
BRACING FORCES SHALL BE CONSIDERED TO BE BOTH TENSION AND
COMPRESSION.
4. 'R' INDICATES BRACE BEAM VERTICAL REACTION. REFER TO FRAMING PLAN
AND/OR BRACED FRAME ELEVATIONS. REACTIONS INDICATED ON BRACE
BEAM DO NOT INCLUDE THE EFFECTS FROM THE VERTICAL COMPONENT OF
BRACE FORCE. WHERE 'R' IS NOT SHOWN, USE SIMPLE BEAM REACTION
EQUAL TO ONE-HALF THE UNIFORM LOAD CAPACITY.
5. 'Cu' INDICATES HORIZONTAL FORCES THAT MUST BE TRANSFERED THROUGH
THE COLUMN. THE FORCES SHOWN ON PLAN ARE FACTORED AXIAL FORCES
IN KIPS. THE FORCES ARE TO BE CONSIDERED TO OCCUR IN EITHER
DIRECTION IN THE DESIGN OF BRACING CONNECTION.
6. THE STRUCTURAL STEEL FABRICATORS ENGINEER SHALL DESIGN
CONNECTIONS (GUSSET PLATES, STEEL ANGLES, SIZE/QUANTITY OF BOLTS
AND WELDS) FOR THE FORCES SHOWN ON THESE BRACED FRAME
ELEVATIONS.
THE FABRICTOR SHALL SUBMIT CONNECTION DESIGN CALCULATION SIGNED
AND SEAJED BY A PROFESSIONAL ENGINEER REGISTERED IN THE STATE
WHERE THE PROJECT IS LOCATED.
7. BOLTED CONNECTIONS THAT ARE PART OF BRACED FRAMES SHALL UTILIZE
SLIP CRITICAL ASTM A3S5 OR A490 HIGH STRENGTH BOLTS.
8. DECK AND SLAB NOT SHOAN FOR CLARITY PURPOSE.
COLUMN, SEE
ELEVATION
BRACE, SEE
ELEVATION
GUSSET PLATE
AS REQUIRED
WORK
POINT
BASE PLATE AND
ANCHOR BOLTS,
SEE PLAN AND
SCHEDULE
TOP OF FOUNDATION,
SEE PLAN
ERECTION
BOLT
BRACE
CENTER
LINE
COLUMN
CENTER
LINE
AS REQ'D
AS REQ'D
AS REQ'D
COLUMN, SEE
ELEVATION
BEAM, SEE
ELEVATION
GUSSET PLATE
AS REQUIRED
BRACE, SEE
ELEVATION
ERECTION
BOLT
STIFFENER PLATES
AS REQUIRED
COLLECTOR BEAM,
SEE PLAN
BOLTED CONNECTIONS
AS REQUIRED
WORK
POINT
BOLTED
CONNECTIONS
AS REQUIRED
BEAM
CENTER
LINE
BRACE
CENTER
LINE
COLUMN
CENTER
LINE
AS REQ'D
AS REQ'D
Cu
BEAM, SEE
PLAN
WORK
POINTBEAM STIFFENERS
AS REQUIRED
BRACE, SEE
ELEVATION
BRACE, SEE
ELEVATION
GUSSET PLATE
AS REQUIRED
ERECTION
BOLT
GUSSET PLATE
STIFFENER AS
REQUIRED
BEAM
CENTER
LINE
BRACE
CENTER
LINE
BRACE
CENTER
LINE
AS REQ'DAS REQ'D
AS REQ'D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:3
P
M
S600
BRACED FRAMED ELEVATIONS AND
DETAILSCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
1/8" = 1'-0"S600
1 BRACE ELEV ALONG GRID 1
1/8" = 1'-0"S600
2 BRACE ELEV ALONG GRID 6
1/8" = 1'-0"S600
3 BRACE ELEV ALONG GRID 12
1/8" = 1'-0"S600
4 BRACE ELEV ALONG GRID B
1/8" = 1'-0"S600
5 BRACE ELEV ALONG GRID C
1/8" = 1'-0"S600
6 BRACE ELEV ALONG GRID 4
1/8" = 1'-0"S600
7 BRACE ELEV GRID D4-D5
1/8" = 1'-0"S600
8 BRACE ELEV ALONG GRID 9
1/8" = 1'-0"S600
9 BRACE ELEV GRID D8-D9
3/4" = 1'-0"S600
10 BRACE DETAIL NOTES
3/4" = 1'-0"S600
11 BRACE DETAIL AT FOUNDATION
3/4" = 1'-0"S600
12 BRACE DETAIL AT ROOF
3/4" = 1'-0"S600
13 CHEVRON BRACE DETAIL
Pu= +/- 5k Pu=
5k
Pu= +/- 5k Pu=
5k
High Roof 20' - 6"
Roof 14' - 0"
21'-0"
HSS6X2X3/16
HSS6X2X3/16HSS6X2X3/16
HSS6X2X3/16
3' - 3 1/2"
10' - 6 3/4"
14' - 7 1/2"
18' - 8 3/4"
FIRST
0' - 0"
HSS6X6X5/16
HSS10X6X3/8
HSS6X6X1/4
HSS8X6X5/16
2'-4 1/4"
S400
S501 H
S S
X
X
/1
H S
S X
X
/1
High Roof 20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
HSS6X6X5/16
HSS10X6X3/8
HSS6X6X1/4
HSS8X6X5/16
21'-0"
2'-4 1/4"
3' - 3 1/2"
10' - 6 3/4"
14' - 7 1/2"
18' - 8 3/4"
S400
S501
HSS6X2X3/16
HSS6X2X3/16
HSS6X2X3/16
HSS6X2X3/16
DEDUCT
ALT #4
678 6.36.6
High Roof 20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
HSS6X4X1/4 HSS6X4X1/4
5'-3"5'-3"5'-3"3'-6" 3'-10" 3'-10" 5'-3" 5'-3" 5'-3" 3'-6"
7'-8" 7'-8" 7'-8" 7'-8"
21'-0" 21'-0"
S400
S501
C4x5.4 SILL
POST TYP.
C4x5.4
HANGER TYP.
13' - 0 1/4"
D E
High Roof 20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
14' - 7 1/2"
18' - 6 3/4" HSS6X6X1/4
HSS6X4X3/16
13'-8"
3'-8 1/4" 8'-3 1/2" 1'-8 1/4"
HSS6X2X3/16 HSS6X2X3/16
S501
DE
High Roof 20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
HSS6X4X3/16
HSS6X6X1/4
14' - 7 1/2"
18' - 6 3/4"
13'-8"
1'-8 1/4" 8'-3 1/2" 3'-8 1/4"
DEDUCT
ALTERNATE
#6
6.36.6
High Roof 20' - 6"
Roof 14' - 0"
FIRST
0' - 0"
HSS6X6X1/4
9'-8"
9 1/4"4'-0 3/4"4'-0 3/4"9 1/4"
S501
10' - 2 5/16"
HSS5x3x1/4 POST
TYP OF 3 (DEDUCT
ALTERNATE #4)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
P
V
A M
C
E y e
C lin ic \B
IM
M o d e ls
\R e v it
\V
A M
C C o lu m b ia
S
T R
U C
T R
.r v t
/1
/2
:3
:4
P
M
S610
FRAMING ELEVATIONS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
FITZPATRICK ENGINEERING GROUP
19520 West Catawba Ave, Suite 311
Cornelius, NC 28031
(704) 987-9114
Douglas Fitzpatrick
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 DF CS
1/8" = 1'-0"S610
1 ELEV 1 ALONG GRID E
1/8" = 1'-0"S610
2 ELEV 2 ALONG GRID E
1/8" = 1'-0"S610
3 ELEV ALONG GRID D
1/8" = 1'-0"S610
4 ELEV ALONG GRID 5
1/8" = 1'-0"S610
5 ELEV ALONG GRID 8
1/8" = 1'-0"S610
6 ELEV ALONG GRID D.6
DEDUCT
ALT #4
S S S
CRCRCRCR
CR
PP
PP
C R
C R
CR
C R
CR
CR
C R
CR
CR
S S
S S
S S
S
S
SSSSS
S S S S S
S S
S
S S
S S
SSS
S S S S
S S
S S
SSS
S S
S
SSSS
CR
HO
PP
1 HOUR FIRE BARRIER in accordance with NFPA 101 Section 8.3 Fire Barrier
WALL RATING LEGEND
SMOKE BARRIER in accordance with NFPA 101 Section 8.5 Smoke Barrier
7 8 9 10 11 12
E
A
654321
D
6.3 6.6
D.6
B
AE-201
A1
AE-201
E1
D6
AE-301
F1
AE-301
F1
AE-301
EYEGLASS
FIT D&D
1A1031A103
CONFERENCE
1A0591A059
OPHTH
CHIEF
1A0521A052
YAG LSR
1A0491A049
PRE-OP
EX 2
1A0321A032
PRE-OP
EX 1
1A0341A034
EX 4
1A0251A025
PHOTO
1A0451A045
EX 7
1A0421A042
EX 5
1A0881A088
EX 6
1A0861A086
EX 7
1A0841A084
EX 8
1A0771A077
EX 3
1A0951A095 EX 4
1A0971A097
TLT
1A1121A112
TLT
1A1061A106
RME
DROP-OFF
1A0731A073
LOW VIS
1A0641A064
HAC
1A1041A104
MECH
1A0921A092
VF 1
1A0811A081
WAITING
1A1011A101
VEST
1A0011A001
WAITING
1A0111A011
OCT 2
1A0271A027
VF 1
1A0471A047
NURSE
WKRM
1A0261A026
EX 3
1A0281A028
COMM
1A0161A016
EQPT ALC
1A0311A031
EX 9
1A0761A076
EX 10
1A0741A074
EX 11
1A0721A072
EX 10
1A0481A048
EX 9
1A0461A046
EX 8
1A0441A044
CORR
1A0901A090
CORR
1A0801A080
LOBBY
1A0001A000
CORR
1A0401A040
CORR
1A0201A020
CORR
1A0701A070
LOCKER
1A056A1A056A
SHARED
OFF
1A0871A087
SHARED
OFF
1A0781A078
SHARED
OFF
1A0541A054
EX 12
1A0681A068
BROS
1A0021A002
VIST
1A0041A004
SHARED
OFF
1A0581A058
ELEC
1A1081A108
TLT
1A0121A012
TLT
1A0571A057
TLT
1A0141A014
EX 6
1A0431A043
HAC
1A0411A041
VEST
1A0211A021
ELEC
1A0241A024
CORR
1A0301A030
COMM
1A1021A102
HLD STOR
1A0691A069
TLT
1A0751A075
REPROCESS
1A0711A071
WHCH
ALC
1A101A1A101A
MED PREP
1A0671A067
EX 5
1A0231A023
TLT
1A0551A055
VALVE
1A0891A089
WHCH
ALC
1A011A1A011A
EYEBROW
CANOPY
ABOVE
C
AE-401
C3
AE-401
F3
AE-402
F3
AE-402
C3
AE-403
F3
AE-404
C3
AE-405
F3
AE-405
C3
AE-406
F3
AE-406
C3
F1
AE-351
AE-401
E3
AE-401
B3 AE-407
E3
AE-408
F3
AE-408
E3
FEC-1FEC-1
FEC-1
EX 1
1A0941A094
VEST
1A0911A091
EX 2
1A0931A093
OCT 2
1A0831A083
OCT 1
1A0851A085
VF 2
1A0791A079
PROCEDURE
1A0221A022
LOUNGE
1A0561A056
CORR
1A1001A100
CORR
1A0101A010
SHARED
OFF
1A0621A062
SHARED
OFF
1A0821A082
EX 13
1A0661A066
OCT 1
1A0291A029
1A
1A
1A
1A
1A
1A
1A049
1A
1A
1A
1A
1A
1A
1A041
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A012 1A016
1A
1A
1A
1A
1A006-A
1A
1A
1A002
1A
1A
1A071
1A
1A
1A
21A
1A1061A112
1A
1A
1A
1A
1A
1A
1A097
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A
1A095
1A
1A
1A091B 1A021B1A100B
1A010B
21'-0" 7'-11"
CLR
6'-0" 5'-4" 1'-9" 2'-3"
CLR
8'-0" 10'-3" 6"
2'-1" 13'-6" 5'-5" 7'-8" 5'-6" 7'-10"
1' -6
'-3
C
LR
8' -0
9"
'-0
5'
-5
4' -7
9"
7' -7
5"
'-3
1'
-6
A6
AE-403
C3
AE-404
F3
AE-407
C3
AE-407
B3
AE-407
F3
AE-408
C3
AE-409
E3
AE-410
B3
AE-408
B3
AE-409
C3
AE-409
B3
AE-401
F7
AE-401
E7
5'-5" 10'-6" 10'-6" 10'-6" 9'-0" 8'-11" 13'-7"
A8A
A4
J3
A
A4 J3
9'-0" 15'-4" 10'-6" 10'-6" 10'-6" 10'-6" 10'-6" 4'-8"4'-10" 10'-6" 10'-6" 10'-6" 3'-6" 13'-10" 10'-6" 10'-6" 10'-6" 10'-6"
A4
J3
8'-0" 2'-2"
A
A
6' -4
A6
A4
6"
9" 7'
-7
9' -2
4'
-4
6' -0
6"
9" 7'
-7
AE-410
F3
COPY
1A006A1A006A
F9
AE-351
D1
AE-301
2' -0
/2
EYEBROW
CANOPY
ABOVE
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #2
DEDUCT ALTERNATE #2
DEDUCT ALTERNATE #7 DEDUCT ALTERNATE #7
1A
1A
6A
AE-411
B3
AE-353
F1
AE-411
D3
AE-411
F6
F8
AE-351
F6
AE-351
F1
AE-351
C9
AE-201
AE-353
B1
AE-353
B4
ALUMINUM
LADDER WITH
FALL ARREST
SYSTEM
6"
3"
4"
6"9"
J2
6"
WC1LAV1
1C
1CA
9V
9V
1CA
1C
9V
1CA
1C
9V
9V
1C
1CA
9V
9V
9 9
9V
TYP
AE-201
C1
AE-201
C4
F2
AE-351 F4
AE-351
1A
1A
1A092
1A089
1A021A
1'-6" 1'-10"
MO
6'-0" 4'-8"
MO
6'-0" 2'-6" 2'-2"
MO
6'-0" 6'-0"
MO
6'-0" 10" 8'-6"
MO
6'-0" 6'-6" 8'-10"
MO
6'-0" 6'-2" 8'-6"
MO
6'-0" 6'-6" 11'-6"
MO
6'-0" 3'-6" 6"
MO
6'-0" 4'-0"
MO
6'-0" 4'-6" 12'-2"
MO
6'-0" 2'-10" 1'-10"
MO
6'-0" 4'-8"
MO
6'-0" 2'-6" 2'-2"
MO
6'-0" 4'-8"
MO
6'-0" 2'-2" 2'-6"
MO
6'-0" 4'-8"
MO
6'-0"
1'-10" 1'-6"
'-4
M
O 6'
-4
3' -4
M
O 6'
-0
4' -8
M
O 6'
-0
1' -1
0" 4'
-2
M O
4' -4
4'
-0
M O
6' -4
4'
-8
234'-0"
1'-6" 21'-0" 21'-0" 21'-0" 21'-0" 21'-0" 5'-8" 9'-8" 5'-8" 21'-0" 21'-0" 21'-0" 21'-0" 21'-0" 1'-6"
'-0
AE-201
F1
24'-4"
MO
6'-0" 4'-8"
MO
6'-0" 4'-8"
MO
6'-0" 4'-4" 6'-0" 1'-0" 4'-0"
(CAST STONE) MO
16'-0" 4'-0"
87'-0" 60'-0" 87'-0"
2'-6"
MO
7'-8" 2'-6"
23'-8"
(CAST STONE)
12'-8" 23'-8" 4'-0"
(CAST STONE) MO
16'-0" 4'-0" 1'-0"
MO
6'-0" 4'-4"
MO
6'-0" 4'-8"
MO
6'-0" 4'-8"
MO
6'-0" 24'-4"
AL1AL2AL2AL2AL3AL3AL1AL1AL1AL1
1' -6
6'
-6
1' -6
8' -0
AL6 AL6
1' -6
'-2
1' -6
'-8
C9
AE-201
OPH
AE-201
F1
OPH
AL7
1'-6"1'-6"
4' -0
1' -6
'-0
'-0
'-0
1' -6
8' -4
8'
-0
5' -8
1A091A
'-0
M O
4' -4
6'
-0
M O
6' -0
4'
-8
M O
6' -0
'-0
A L2
A L2
AL2AL2AL2AL2AL1AL1AL1AL1AL1AL1AL2AL2AL1AL1AL2AL2AL2
234'-0"
3'-8" 7'-1" 13'-11" 8'-8" 9'-0"
9' -8
'-7
9"
'-0
'-0
9"
9'-6"
CL
CLCL
CLCLCLCLCL
DPS DPS
A L2
A L1
A6
FEC-1 FEC-1
A4 A4
DPSDPS
DPS
A6A
C L
DPS
DPS
DPS
J3
J3
D P
S
A
7'-10" 2'-8" 2'-10" 7'-8" 5'-10"
CLR
8'-0" 4'-0" 3'-2" 6'-9"
CLR
6'-0" 8" 7'-4" 7'-8" 3'-0" 3'-0"
DPS
DPS
CL
A
A
A 6 A
A
E
A
J3
J3 J3
J3
11" 29'-7"2'-6"
5"
AE-602
E4
AE-602
E6
AE-602
E1
AE-352
D7
AL4 (ABOVE) AL4 (ABOVE)
1A
1B
5'-8" 15'-4" 8"
CLR
6'-0" 14'-4"
AE-351
B4
AE-353
B6
A
AE-353
D4
F E
C -1
1A
6- B
AE-353
B8
4"
J2
7"
7"
7"
6"
6" J3
J2
AE-353
D1
DPS
D P
S
D P
S
DPS
D P
S
RECEPTION
1A006
DPS
2' -7
2' -0
DEDICATION PLAQUE -
COORDINATE LOCATION
WITH CONTRACTING
OFFICER
HAC
1A073H1A073H
1A
3H
CARD READER
HOLD OPEN
PUSH PAD
DOOR POSITION SWITCH
AUTOMATIC OPERATOR
FLOOR PLAN LEGEND
DPS
FOR ADDITIONAL SYMBOLS, SEE GI-003
NOTE: COORDINATE
LOCATION OF TRASH
ENCLOSURE WITH CIVIL
'-0
12'-0"
F8
AE-353
5" BOLLARD - SEE CIVIL
BRONZE PAINTED
METAL GATE
AE-101
B7
'-0
6' -0
GATE
10'-0" OPENING
5" BOLLARD - SEE CIVIL
10'-0"BRONZE COLORED
METAL COPING
BRONZE PAINTED
METAL GATE
AE-101
A7
FACE BRICK
BRONZE COLORED
METAL COPING
FACE BRICK ON
CMU BACKUP
3" 6"
6"
6" 1" 5 1/2" 1/2"
WELD LOWER COLLAR
TO POST, BOLT UPPER
METAL COLLAR
METAL TO BE PAINTED
BRONZE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
09/29/2023
C rv t\
\V
A M
C E
Y E
C L
IN
IC
A
C E
N T
R A
L
F
IN
A L jo e c a m p is i.
rv t
/2
/2
:4
:1
P
M
AE-101
FIRST FLOOR PLAN
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
NN RB
7. REFER TO INTERIOR DRAWINGS FOR
ADDITIONAL INTERIOR FINISH INFORMATION.
6. REFER TO EQUIPMENT DRAWINGS FOR
ADDITIONAL EQUIPMENT INFORMATION.
5. REFER TO MEP DRAWINGS FOR ADDITIONAL
MEP INFORMATION.
4. REFER TO STRUCTURAL DRAWINGS FOR
ADDITIONAL STRUCTURAL INFORMATION.
3. ALL DIMENSIONS ARE TO COLUMN
CENTERLINES OR FACE OF FINISHED WALLS
OR SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONAL
INFORMATION IS REQUIRED AND NOT FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS AND SPECIFICATIONS ARE
COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL
DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY
ARCHITECT IMMEDIATELY FOR CLARIFICATION
IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
GENERAL NOTES
NORTH
PLAN
NORTH
1/8" = 1'-0" F1
FIRST FLOOR PLAN
4 8 168 0
1/8" = 1'-0" B6
DUMPSTER ENCLOSURE PLAN
1/4" = 1'-0"
B7
DUMPSTER ENCLOSURE ELEVATION
1" = 1'-0" A7
GATE HINGE DETAIL
J J
J
7 8 9 10 11 12
E
A
654321
D
6.3 6.6
D.6
B
AE-201
A1
AE-201
E1
D6
AE-301
F1
AE-301
F1
AE-301
ALUMINUM LADDER
WITH FALL ARREST
SYSTEM
RE: SPECIFICATIONS
RTU-1, REFER TO
MECHANICAL
RTU-2, REFER TO
MECHANICAL
CHILLER,
REFER TO
MECHANICAL
C
F1
AE-351
F9
AE-351
D1
AE-301
PREFABRICATED
EYEBROW CANOPY
PREFABRICATED
EYEBROW CANOPY
F8
AE-351
F6
AE-351
C9
AE-201
AE-201
C1
AE-201
C4
F2
AE-351
F4
AE-351
AE-201
F1
1' -6
'-6
1'-6"
1' -6
HANGING GUTTER -
CONTINUOUS
110'-8" 12'-8" 23'-8" 87'-0"
TPO ROOFING MEMBRANE
TAPERED ROOF
INSULATION
HANGING GUTTER -
CONTINUOUS
SPLASH PAN
'-0
TPO ROOFING MEMBRANE
TAPERED ROOF
INSULATION
HANGING GUTTER -
CONTINUOUS
SPLASH PAN
GFRG CORNICE
PRE-FINISHED
ALUMINUM COPING
PRE-FINISHED
ALUMINUM COPING
GFRG CORNICEPRE-FINISHED
ALUMINUM COPING
EQ EQ
1'-6"
GFRG CORNICE
PRE-FINISHED
ALUMINUM COPING
TPO ROOFING MEMBRANE
1' -6
8'
-0
ROOF WALKWAY
PROTECTION
1' -6
A5
AE-352A5
AE-352
AE-351
B8
C1
AE-102
1'-6"
'-8
ROOF WALKWAY
PROTECTION
1/ 4"
F
T M
IN
S
LO
P E
1/ 4"
F
T
P E
1/ 4"
F
T
P E
1/ 4"
F
T
P E
1/ 4"
F
T
P E
DS DSDSDSDSDS
1'-6"
CHILLER PUMP,
REFER TO
MECHANICAL
1/ 4"
F
T
P E
1/ 4"
FT
SL
O P
E
HP
HP
1/4" / FT MIN
SLOPE
HP
HP1/8" / FT MIN
SLOPE
EXTERIOR
COMPRESSOR
SEE MECHANICAL
EXTERIOR
COMPRESSOR
SEE MECHANICAL
F6
AE-351
SIM
1/4" / FT M
P E
1/ 4"
FT
SL
O P
E
1/4" / FT M
P E
C1
AE-102
C1
AE-102
C1
AE-102
C1
AE-102
C1
AE-102
C1
AE-102
AE-102
C5
AE-102
C5
ROOF VENT - REFER TO
PLUMBING
ROOF VENT - REFER TO
PLUMBING
ROOF VENT - REFER TO
PLUMBING
ROOF VENT - REFER
TO PLUMBING
ROOF VENT - REFER
TO PLUMBING
ROOF
VENT -
REFER TO
PLUMBING
TPO ROOFING SYSTEM
1/2" GYPSUM COVER BOARD
TPO ROOFING SYSTEM
CONTINUOUS RIGID INSULATION
(R-23.6)MIN THICKNESS 4"
STAINLESS STEEL REGLET FLASHING AND
COUNTERFLASHING
ROOF EQUIPMENT- REFER TO MECHANICAL
PRE-MANUFACTURED ROOF
CURB- REFER TO MECHANICAL
CONTINUOUS BED OF SEALANT
NOTE: COORDINATE ALL SLAB
OPENINGS WITH MECHANICAL
& STRUCTURAL DRAWINGS
1/2" GYPSUM COVER BOARD
METAL DECK- REFER
TO STRUCTURAL
STAINLESS STEEL
REGLET AND COUNTER
FLASHING INSIDE
CORNER TRANSITION
ROOFING SYSTEM
CONTINUOUS
PREFABRICATED
STAINLESS STEEL
FLASHING SADDLE
EXTERIOR GYPSUM
SHEATHING
ROOFING SYSTEM
ADDITIONAL STAINLESS
STEEL REGLET AND
COUNTER FLASHING
CONTINUOUS THRU-
WALL FLASHING WITH
TERMINATION BAR
EXTERIOR GYPSUM
SHEATHING
PARAPET COPING
INTERSECTION AT
WALL - STEP 2
PARAPET COPING
INTERSECTION AT
WALL - STEP 3
ROOFING SYSTEM
COPING
CONTINUOUS THRU-
WALL FLASHING WITH
TERMINATION BAR
SEALANT
ADDITIONAL BRICK
MATERIAL
EXTERIOR GYPSUM
SHEATHING
FLUID APPLIED AIR
BARRIER
THRU-WALL FLASHING
SADDLE
THRU-WALL FLASHING
SADDLE
ROOFING
MEMBRANE
PARAPET COPING
INTERSECTION AT
WALL - STEP 1
ROOFING
MEMBRANE
1/2" GYPSUM COVER BOARD
PRE-MOLDED QUICK SEAM
PIPE FLASHING
STAINLESS STEEL
CLAMP RING
CONTINUOUS BEAD
OF HIGH GRADE
URETHANE SEALANT
INSTALL MEMBRANE
SO THAT IT EXTENDS A
MIN OF 1/2" UP PIPE
TPO ROOFING
SYSTEM
ATTACH FLASHING PER
MANUFACTURER
RECOMMENDATIONS
TPO PATCH HEAT FUSED IN
PLACE. MEMBRANE MUST BE
A MIN OF 4" LARGER THAN
DIAMETER OF PIPE FLASHING,
PER MANUFACTURER
RECOMMENDATIONS
CONTINUOUS RIGID
INSULATION (R-23.6)MIN
THICKNESS 4"
METAL DECK- REFER
TO STRUCTURAL
1/2" GYPSUM COVER BOARD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C rv t\
\V A
M C
E Y
E C
L
IN
IC
A
C E
N T
R A
L s te p h e n
.n u tt a ll2
Z U
K .r v t
/9
/2
:2
:0
P M
AE-102
ROOF PLAN
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 NN RB
1/8" = 1'-0" F1
ROOF PLAN
7. REFER TO INTERIOR DRAWINGS FOR
ADDITIONAL INTERIOR FINISH INFORMATION.
6. REFER TO EQUIPMENT DRAWINGS FOR
ADDITIONAL EQUIPMENT INFORMATION.
5. REFER TO MEP DRAWINGS FOR ADDITIONAL
MEP INFORMATION.
4. REFER TO STRUCTURAL DRAWINGS FOR
ADDITIONAL STRUCTURAL INFORMATION.
3. ALL DIMENSIONS ARE TO COLUMN
CENTERLINES OR FACE OF FINISHED WALLS
OR SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONAL
INFORMATION IS REQUIRED AND NOT FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS AND SPECIFICATIONS ARE
COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL
DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY
ARCHITECT IMMEDIATELY FOR CLARIFICATION
IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
GENERAL NOTES
NORTH
PLAN
NORTH
1 1/2" = 1'-0" C1
MECHANICAL EQUIPMENT ROOF CURB - TYPICAL SECTION DETAIL
1 1/2" = 1'-0"
C5
PARAPET COPING - DETAIL
1 1/2" = 1'-0" C3
ROOF PENETRATION - TYPICAL SECTION DETAIL
S S
S S
S
S
SSSSS
S S S S S
S S
S
S S
S S
SSS
S S S S S
S S
S
SSS
S S
S
SSSS
S
7 8 9 10 11 12
E
A
654321
D
6.3 6.6
D.6
B
D6
AE-301
F1
AE-301
F1
AE-301
C
AE-402
F5
AE-402
C5
AE-403
F5
AE-404
C5
AE-405
F5
AE-405
C5
AE-406
F5
AE-406
C5
F1
AE-351
AE-403
C5
AE-404
F5
AE-410
B7
CONFERENCE
OPHTH
CHIEF
YAG LSR
PRE-OP
EX 2
PRE-OP
EX 1
EX 4
PHOTO
EX 7EX 5 EX 6 EX 7
EX 8
EX 3 EX 4 TLT TLT
RME
DROP-OFF
LOW VIS
RECEPTION
HAC
MECH
VF 1
EYEGLASS
FIT D&D
WAITING
VEST
OCT 2
VF 1
NURSE
WKRMEX 3
COMM
EQPT ALC
EX 9 EX 10 EX 11
LOUNGE
EX 10 EX 9 EX 8
CORR
CORR
LOBBY
CORR
CORR
CORR
LOCKER
SHARED
OFF
SHARED
OFF
SHARED
OFF
EX 12
BROS
VIST
SHARED
OFF
ELEC
TLT
TLT
TLT
EX 6
HAC
VEST
ELEC
CORR
COMM
HLD STOR
TLT
REPROCESS
WHCH
ALC
MED PREP
EX 5
TLT
VALVE
WHCH
ALC
EX 1
VEST
EX 2
OCT 1 OCT 2 VF 2
PROCEDURE
CORR
CORR
SHARED
OFF
SHARED
OFF
EX 13
OCT 1
COPY
WAITING
F9
AE-351
D1
AE-301
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #2
DEDUCT ALTERNATE #2
DEDUCT ALTERNATE #7
DEDUCT ALTERNATE #7
EYEBROW
CANOPY
EYEBROW
CANOPY
ABOVE
AE-411
B6
F8
AE-351
F6
AE-351
C9
AE-201AE-411
D6
AE-411
F8
5'-0"
E Q
3' -4
E Q
EQ
4'-0” EQ
E Q
4' -0
E
Q
E Q
4' -0
E
Q
4'-0"
EQ
6' -6
3'
-3
/2
EQ
8'-0" AFF
2'-6"
A
LI
G N
A
LI
G N
9' -6
A
F F
8' -6
A
F F
8'-6" AFF
1' -4
A
LI
G N
A
LI
G N
A
LI
G N
A
LI
G N
A
LI
G N
A
LI
G N
9' -6
A
F F
8'-6" AFF
8'-0" AFF
EQ 4'-6" EQ
E Q
E Q
1' -4
3' -3
/2
6'
-6
EQ EQ
8'-6" AFF
7'-6" AFF7'-6" AFF
7 7
1' -4
8'-6" AFF
1' -4
F2
AE-351
F4
AE-351
18'-8" AFF 18'-8" AFF
8' -0
A
F F
10'-4" AFF
8'-10" AFF
9' -6
A
F F
9' -6
A
F F
8' -6
A
F F
8' -6
A
F F
10'-0" AFF
10'-0" AFF
9'-0" AFF
8' -0
6'-0"
9'-8" AFF
8'-9" AFF 8'-9" AFF
8'-0" AFF
8' -4
A
F F
8'-6" AFF 1'
-4
8'-4" AFF
10'-0" AFF
AE-410
F5
ALUMINUM
LADDER
HAC
1'-4"5'-2"
5' -8
E
Q E
Q
RCP SYMBOL LEGEND
SUSPENDED LINEAR FLUORESCENT LIGHT
FIXTURE
SMOKE DETECTOR
SPEAKER
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
EXIT LIGHT
HEAT DETECTOR
HVAC EXHAUST DIFFUSER
RECESSED OR SURFACE MOUNTED
FLUORESCENT LIGHT FIXTURE
GYPSUM CEILING - PAINTED
ACOUSTICAL TILE CEILING (24x24)
PLASTIC LAMINATE WALL PANEL SOFFIT
8'-6"
GWB-1 (P-1)
HEIGHT
CEILING MATERIAL (FINISH)
THIS SYMBOL USED FOR CLGS NOT IDENTIFIED
BY CEILING GENERAL NOTES OR ROOM FINISH
SCHEDULE
CEILING MOUNTED CUBICAL CURTAIN TRACK
PENDANT LIGHT FIXTURE
RECESSED DOWN LIGHT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
09/29/2023
C rv t\
\V
A M
C E
Y E
C L
IN
IC
A
C E
N T
R A
L
F
IN
A L jo e c a m p is i.
rv t
/2
/2
:4
:0
P
M
AC-101
FIRST FLOOR REFLECTED CEILING
PLANCharlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
NN RB
1/8" = 1'-0" F1
REFLECTED CEILING PLAN
7. REFER TO INTERIOR DRAWINGS FOR
ADDITIONAL INTERIOR FINISH INFORMATION.
6. REFER TO EQUIPMENT DRAWINGS FOR
ADDITIONAL EQUIPMENT INFORMATION.
5. REFER TO MEP DRAWINGS FOR ADDITIONAL
MEP INFORMATION.
4. REFER TO STRUCTURAL DRAWINGS FOR
ADDITIONAL STRUCTURAL INFORMATION.
3. ALL DIMENSIONS ARE TO COLUMN
CENTERLINES OR FACE OF FINISHED WALLS
OR SURFACES UNLESS NOTED OTHERWISE.
2. DO NOT SCALE DRAWINGS. IF DIMENSIONAL
INFORMATION IS REQUIRED AND NOT FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR
CLARIFICATION.
1. DRAWINGS AND SPECIFICATIONS ARE
COMPLIMENTARY COMPONENTS OF THE
CONTRACT DOCUMENTS, REVIEW ALL
DRAWINGS AND SPECIFICATIONS FOR THE
COMPLETE SCOPE OF WORK. NOTIFY
ARCHITECT IMMEDIATELY FOR CLARIFICATION
IF INCONSISTENCIES, CONTRADICTIONS OR
OMISSIONS ARE DISCOVERED.
GENERAL NOTES
NORTH
PLAN
NORTH
4 8 168 0
KEYNOTES - SHEET
7 CENTER LIGHT FIXTURE IN CEILING
13 START CEILING WITH WHOLE GRID ALONG THIS WALL
789101112 6 5 4 3 2 16.36.6
FIRST FLOOR
0"
D6
AE-301
FACE BRICK
(BR-1)
F1
AE-351
CAST STONE
VENEER (EXT-1)
F9
AE-351
D1
AE-301
DEDUCT
ALTERNATE #4 DEDUCT
ALTERNATE #4
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #7
F8
AE-351
F6
AE-351
C9
AE-201
FACE BRICK SILL
(BR-1) - BRICK
RECESSED AT SILL -
RUNNING BOND
F2
AE-351
F4
AE-351
VERTICAL SUN
SHADE FIN
FACE BRICK SILL
(BR-1) - BRICK
RECESSED AT
SILL - RUNNING
BOND
FACE BRICK REVEAL
(BR-1) - RUNNING BOND
FACE BRICK (BR-1)
PRE-FINISHED ALUMINUM
COPING
FACE BRICK CORBEL
PATTERN (BR-1) -
SOLDIER COURSE
FACE BRICK HEADER (BR-1) -
SOLDIER COURSE
ALUMINUM CURTAIN
WALL AND DOOR
CAST STONE
VENEER (EXT-1)
FACE BRICK (BR-1) -
SOLDIER COURSE
ALUMINUM CURTAIN
WALL WITH INSULATED
SPANDREL PANELS
AND GLAZING
FIBER GLASS REINFORCED
CONCRETE CORNICE (EFS-1)FIBER
REINFORCED
CORNICE
BRONZE COLORED
METAL EYEBROW
CANOPY
9'-0 WIDE X 6'-0" DEEP PRE-FINISHED
CANOPY SUPPORTED BY HANGER RODS
CAST STONE (EXT-1)
BANDING DEDUCT
ALTERNATE #5
AL2
AL3
AL4 AL4
AL3
AL2AL2
AL1
AL6 AL6
AL1 AL1 AL1 AL1
F2
AE-351
CJ CJ
UPPER ROOF
BEARING
20' - 6"
21'-0"
SEE F2/AE-201 FOR BRICK CORBEL PATTERN
34'-0" 21'-0"
SEE F2/AE-201 (OPP HAND) FOR BRICK CORBEL PATTERN
34'-0"
CJ CJCJ
CJ
CJ
CJ CJCJ CJ
DEDICATION PLAQUE -
COORDINATE LOCATION
WITH CONTRACTING
OFFICER
EQEQ
7 8 9 10 11 12654321 6.3 6.6
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
D6
AE-301
F9
AE-351
D1
AE-301
F2
AE-351
F4
AE-351
FACE BRICK HEADER
(BR-1) - SOLDIER COURSE
ALUMINUM CURTAINWALL WINDOW
WITH INSULATED GLAZING UNITS
FACE BRICK CORBEL
PATTERN (BR-1) -
SOLDIER COURSE
PRE-FINISHED
ALUMINUM COPING
AL2AL2AL2AL2
AL1AL1AL1AL1AL1AL1
AL2AL2
AL1AL1
AL2AL2AL2
CJ CJCJ CJ CJ CJ CJ CJ CJ
DEDUCT
ALTERNATE #5
4'-8" DS DS
UPPER ROOF
BEARING
20' - 6"
42'-8"
SEE F2/AE-201 FOR BRICK CORBEL PATTERN
34'-0"48'-8"
SEE F2/AE-201 (OPP HAND) FOR BRICK CORBEL PATTERN
34'-0"
1'-6"
DS
EQ EQ
1'-6"
EQEQDS
1'-6" 1'-6"
DOWNSPOUT (DS) TIED INTO
STORM WATER SYSTEM - SEE CIVIL
PRE-FINISHED
ALUMINUM COPING
PRE-FINISHED
HANGING GUTTER
TPO FLASHING
MEMBRANE AT
VERTICAL WALLS
TPO FLASHING
MEMBRANE AT
VERTICAL WALLS
PRE-FINISHED
DOWNSPOUT TO
SPLASH PAN
GFRC CORNICE CAP
OFF BACK END OF
CORNICE
PRE-FINISHED
ALUMINUM
COPING
PRE-FINISHED
HANGING GUTTER
DS
CJ CJCJCJ
PRE-FINISHED
DOWNSPOUT TO
SPLASH PAN
REDUCE WIDTH OF
SOUTH ELEVATION
WINDOWS TO 4'-0" (TYP.)
DEDUCT
ALTERNATE #3
ED
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
AL20
1'-6" 2'-8" 7'-8" 1'-10" 1'-6"
CAST STONE
VENEER (EXT-1)
FIBERGLASS
REINFORCED CONCRETE
CORNICE (EFS-1)
CAST STONE (EXT-1)
BANDING
AE-352
D1
AE-352
F1
OPP
OPP
UPPER ROOF
BEARING
20' - 6"
DEDUCT
ALTERNATE #4
CAST STONE HEADER
GRADE
TPO FLASHING MEMBRANE
AT VERTICAL WALL
PROVIDE 3'-6" LONG
PIECES AT INSIDE
CORNERS AS REQUIRED
EA D D.6
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
B
F1
AE-301
F1
AE-301
C
FACE BRICK
REVEAL (BR-1) -
RUNNING BOND
PRE-FINISHED
ALUMINUM COPING
FACE BRICK SILL (BR-1) -
BRICK RECESSED AT SILL -
RUNNING BOND
FACE BRICK CORBEL
PATTERN (BR-1) -
SOLDIER COURSE
DOOR AND FRAME,
PAINTED
ALUMINUM CURTAINWALL
WINDOW WITH INSULATED
GLAZING UNITS FACE BRICK HEADER -
SOLDIER COURSE
FACE BRICK (BR-1) -
SOLDIER COURSE
5'-6" WIDE x 5'-0" DEEP PRE-
FINISHED CANOPY SUPPORTED
BY HANGER RODS
FACE BRICK (BR-1)
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #5
AL2AL2
'-0
"CJ
CJ
UPPER ROOF
BEARING
20' - 6"
AE-301
B5
21'-8"
SEE B1/AE-301 FOR BRICK CORBEL PATTERN
23'-4" 22'-0"
PRE-FINISHED
HANGING GUTTER
CJ
DOWNSPOUT (DS) TIED
INTO STORM WATER
SYSTEM - SEE CIVIL
E ADD.6
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
B
F1
AE-301
F1
AE-301
C
ALUMINUM WINDOW
WITH GLAZING
FACE BRICK CORBEL
PATTERN (BR-1) -
SOLDIER COURSE
ALUMINUM LADDER
DOOR AND FRAME, PAINTED
5'-6" WIDE x 5'-0" DEEP PRE-FINISHED
CANOPY SUPPORTED BY HANGER RODS
DEDUCT
ALTERNATE #5
DEDUCT
ALTERNATE #2
DEDUCT
ALTERNATE #6
RETAINING WALL-
REFER TO CIVIL
'-6
AL2
AL1
CJ
CJ
10'-6"
CL
UPPER ROOF
BEARING
20' - 6"
22'-0"
SEE B1/AE-301 (OPP HAND) FOR
23'-4" 21'-8"
BRICK CORBEL PATTERN
PRE-FINISHED
ALUMINUM COPING
CJ
DOWNSPOUT (DS) TIED
INTO STORM WATER
SYSTEM - SEE CIVIL
PRE-FINISHED
HANGING GUTTER
E DD.6
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
4' -2
1' -1
0" M
A S
O N
R Y
O P
E N
IN
G
'-0
2'
-8
CAST STONE VENEER
(EXT-1)
FIBER REINFORCED
CORNICE
CAST STONE (EXT-1)
BANDING
AE-352
D1
AE-352
F1
'-0
UPPER ROOF
BEARING
20' - 6"
PROVIDE 3'-6" LONG PIECES AT
INSIDE CORNERS AS REQUIRED
F6
AE-351
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C rv t\
\V A
M C
E Y
E C
L
IN
IC
A
C E
N T
R A
L s te p h e n
.n u tt a ll2
Z U
K .r v t
/9
/2
:2
:0
P M
AE-201
EXTERIOR ELEVATIONS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 NN RB
1/8" = 1'-0" A1
ELEVATION - PLAN NORTH
1/8" = 1'-0" E1
ELEVATION - PLAN SOUTH
1/8" = 1'-0" C9
VIEW OF CLEARSTORY
4 8 168 0
4 8 168 04 8 168 04 8 168 0
4 8 168 0
1/8" = 1'-0" C1
ELEVATION - PLAN EAST
1/8" = 1'-0"
C4
ELEVATION - PLAN WEST
1/8" = 1'-0" F1
VIEW OF ENTRANCE SIDE
4 8 168 0
COLOR: AMARILLO WHITE CF02
PERCORA CORPORATION
BRICK TO BRICK
COLOR: PUTTY COLOR: AMARILLO WHITE CF02
ARGOS USA COLOR: LIGHT BRONZE PERCORA CORPORATION
M-1 FACE BRICK AND CAST STONE MORTAR FINISH: ANODIZED CAST STONE TO BRICK COLOR: 2-2705 PEPPERMINT PATTY
LADDER MATERIAL: ALUMINUM ARCHITECTURAL URETHANE SEALANTS FINISH: OPACI-COAT 300
MASONRY MORTARING 04 05 13 COLOR: LIGHT BRONZE #26 ICD HIGH PERFORMANCE COATINGS
GLOSS: SEMI-GLOSS JOINT SEALANTS 07 92 00 KAWNEER SPANDREL COATING:
SIZE: 8" HIGH X 16" LONG X 8" DEEP NOMINAL COLOR: SW 7555 PATIENCE FINISH: ANODIZED COLOR: SOLARBAN 70 (2) SOLEXIA
COLOR: GREY SHERWIN WILLIAMS COLOR: SW 6144 - DAPPER TAN FRAME MATERIAL: ALUMINUM TYPE: INSULATED, TINTED, LOW-E, SPANDREL
FINISH: SMOOTH FIELD PAINTED SHERWIN WILLIAMS IL-2 VITRO
TYPE: STANDARD LINTELS STEEL LOOSE AND PLATE AT CAST STONE FINISH: PVDF TO MATCH COLOR BELOW COLOR: LIGHT BRONZE #26
CMU CONCRETE MASONRY UNITS MATERIAL: ALUMINUM KAWNEER COLOR: SOLARBAN 70 (2) SOLEXIA
GLOSS: SEMI-GLOSS HANGING GUTTERS AND DOWNSPOUTS FINISH: ANODIZED TYPE: INSULATED, TINTED, LOW-E VISION
SIZE: MODULAR COLOR: SW 7703 EARTHEN JUG DOOR MATERIAL: ALUMINUM IL-1 VITRO
COLOR: RED BRICK VELOUR SHERWIN WILLIAMS COLOR: SW 6144 - DAPPER TAN
ARCHITECTURAL COLLECTION FIELD PAINTED SHERWIN WILLIAMS AND STOREFRONTS COLOR: CLEAR
CAROLINA CERAMICS LINTELS STEEL LOOSE AND PLATE AT BRICK FINISH: PVDF TO MATCH COLOR BELOW ALUMINUM-FRAMED ENTRANCES 08 41 13 TYPE: MONOLITHIC
BR-1 FACE BRICK MATERIAL: ALUMINUM MG-1 VITRO
METAL FABRICATIONS 05 50 00 COPINGS GLOSS: SEMI-GLOSS
UNIT MASONRY 04 20 00 COLOR: SW 6144 - DAPPER TAN GLAZING 08 80 00
SIZE: 12" HIGH X 36" LONG X 4" DEEP NOMINAL FLASHING AND SHEET METAL 07 60 00 FRAME SHERWIN WILLIAMS
COLOR: CREAM COLOR: WHEAT COLOR: LIGHT BRONZE #26
FINISH: FINE TEXTURE PATTERN: STANDARD VDT COLOR: WHITE GLOSS: SEMI-GLOSS KAWNEER
FORMGLAS PRODUCTS LTD CAST STONE SYSTEMS FIRESTONE BUILDING PRODUCTS COLOR: SW 6144 - DAPPER TAN FINISH: ANODIZED
EFS-1 CORNICE STONE EXT-1 CAST STONE ROOFING MEMBRANE DOOR SHERWIN WILLIAMS FRAME MATERIAL: ALUMINUM
GLASS FIBER REINFORCED CONCRETE (GFRC) 03 45 00 CAST STONE MASONRY 04 72 00 THERMOPLASTIC POLYOLEFIN (TPO) ROOFING 07 54 23 HOLLOW METAL DOORS AND FRAMES 08 11 13 GLAZED ALUMINUM CURTAIN WALLS 08 44 13
EXTERIOR FINISH LEGEND
EA D D.6
0"
B
F1
AE-301
F1
AE-301 C
RETAINING WALL-
REFER TO CIVIL
DEDUCT
ALTERNATE #6
SHARED
OFF
1A078
176 SF
CORR
1A070
1104 SF
EX 8
1A077
131 SF
ELEC
1A108
22 SF
CORR
1A100
463 SF
WAITING
1A101
373 SF
NOTE: SEE STRUCTURAL FOR ALL ROOF
BEARING HEIGHTS - TYPICAL
7 8 9 10 11 12654321 6.3 6.6
FIRST FLOOR
0"
D6
AE-301
D1
AE-301
BRONZE COLORED
METAL EYEBROW
CANOPY
DEDUCT
ALTERNATE #2
F8
AE-351
F6
AE-351
C9
AE-201
F2
AE-351
F4
AE-351
NOTE: SEE STRUCTURAL FOR ALL ROOF
BEARING HEIGHTS - TYPICAL
EA D D.6
FIRST FLOOR
0"
B
F1
AE-301
F1
AE-301 C
LOUNGE
1A056
158 SF
CORR
1A040
650 SF
TLT
1A055
87 SF
TLT
1A014
53 SF
CORR
1A010
249 SF
WAITING
1A011
237 SF
NOTE: SEE STRUCTURAL FOR ALL ROOF
BEARING HEIGHTS - TYPICAL
FIRST FLOOR
0"
C
C
C
8C
'-4
4C
C
C O
U R
S E
S
C
5C 8" 1'-4" 1'-0" 4"
34'-0"
3'-4" 6'-0" 4'-8" 6'-0" 4'-8" 6'-0" 3'-4"
CJ
CJ
7C
C
C
C 9C
4" 2'-0" 1'-0" 1'-0" 4" 4'-0" 2'-0" 1'-0"4" 1'-8" 1'-8"
5C 4C
C
C
5C
8"
'-8
(5 7C
1'-0"1'-0"1'-4"
FIRST FLOOR
0"
B C
CJ
'-8
8"
'-0
(8
C
O U
R S
E S
3'-4" 6'-0" 4'-8" 6'-0" 3'-4"
23'-4"
CJ
1C
C
C
C 5C
C
4" 4"
8" 1'-0" 1'-0" 2'-4" 3'-8" 8" 4" 4"
8" 1'-4" 1'-4" 2'-0" 2'-4" 1'-8" 4"
2'-4" 8"
6C 8C
C
C
C
C
3C
C
C 6C
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C rv t\
\V A
M C
E Y
E C
L
IN
IC
A
C E
N T
R A
L s te p h e n
.n u tt a ll2
Z U
K .r v t
/9
/2
:2
:1
P M
AE-301
BUILDING SECTIONS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 NN RB
1/8" = 1'-0" D6
BUILDING SECTION - B
1/8" = 1'-0" F1
BUILDING SECTION - A
1/8" = 1'-0" D1
BUILDING SECTION - C
4 8 168 0 4 8 168 0
4 8 168 0
1/4" = 1'-0" B1
TYPICAL CORBELING ELEVATION
2 4 84 0 1/4" = 1'-0"
B5
CORBELLING ELEVATION
2 4 84 0DEDUCT ALTERNATE #5 DEDUCT ALTERNATE #5
0"
ROOF (DECK
BEARING)
14' - 6"
CONCRETE SLAB ON
GRADE- REFER TO
STRUCTURAL
CONCRETE
FOOTING- REFER
TO STRUCTURAL
PRE-FINISHED
ALUMINUM COPING
BRICK WALL ASSEMBLY:
- 4" FACE BRICK VENEER
- 1-3/4" AIR SPACE
- 2" RIGID FIBER INSULATION (R-8.4)
- FLUID APPLIED MEMBRANE AIR BARRIER
-GYPSUM SHEATHING BOARD
- 6" COLD FORMED METAL FRAMING
- BATT INSULATION (R-19)
- 5/8" GYPSUM BOARD
FINISHED GRADE-
REFER TO CIVIL
AE-352
D1
3/4" BRICK REVEAL -
SEE ELEVATIONS
4' -2
1'
-2
2' -8
2'
-8
2' -8
2'
-8
2' -8
AE-352
F1
'-8
METAL ROOF
DECK - REFER TO
STRUCTURAL
STEEL ANGLE - REFER
TO STRUCTURAL
STEEL BAR JOISTS AND
PERIMETER STEEL
BEAM - REFER TO
STRUCTURAL
1'-6"
8" 10"
FACE BRICK SOLDIER
COURSE
1'-6"
TPO ROOFING
MEMBRANE
D
FIRST FLOOR
0"
VERTICAL SUN SHADE
FIN - SEE PLAN
SCHEDULED
CEILING
1'-6"
AE-352
D18" 10"
AE-352
F1
'-8
AE-602
F7
AE-602
C6
SPANDREL INSULATION
'-0
6' -0
M
A S
O N
R Y
O P
E N
IN
G
'-0
2'
-8
E D.6
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
4' -2
8"
M A
S O
N R
Y O
P E
N
IN
G 9'
-8
CONCRETE WALK-
REFER TO CIVIL
CAST STONE TRIM (SILL)
ALUMINUM CURTAIN WALL WITH
INSULATED SPANDREL PANELS
AND GLAZING
STONE BASE
ALUMINUM STOREFRONT DOOR
'-0
SCHEDULED CEILING
AE-352
F5
REMANUFACTURED
ALUMINUM CANOPY
AE-352
D5
AE-352
D3
SIM
3' -6
STEEL SUPPORT TUBE -
REFER TO STRUCTURAL
CANOPY HANGER ROD
ASSEMBLY AND EYE-BOLT
STEEL BEAM - REFER
TO STRUCTURAL
STEEL SUPPORT
TUBE - REFER TO
STRUCTURAL
6'-0" CANOPY
C L
E
FIRST FLOOR
0"
ROOF (DECK
BEARING)
14' - 6"
ALUMINUM CURTAINWALL
WINDOW WITH INSULATED
GLAZING UNITS
4' -2
3'
-1 0"
2' -8
M
A S
O N
R Y
O P
E N
IN
G
5' -4
2'
-8
FACE BRICK SOLDIER COURSE
FACE BRICK SOLDIER COURSE
AE-602
C9
AE-602
F9
8" 10"
LOW SLOPE ROOF ASSEMBLY:
- TPO ROOFING MEMBRANE
- COVERBOARD
- 4" THICK ROOF INSULATION (R-20)
- SUBSTRATE BOARD
AE-352
F1
AE-352
D1 1'-6"
'-8
AE-602
F1
E D
FIRST FLOOR
0"
3' -0
4"
7' -0
4'
-0
4" M
A S
O N
R Y
O P
E N
IN
G
3' -4
8"
M A
S O
N R
Y O
P E
N
IN
G 6'
-4
8"
'-0
CAST STONE WALL ASSEMBLY:
- 4" CAST STONE VENEER
- 1-3/4" AIR SPACE
- 2" RIGID FIBER INSULATION (R-8.4)
- FLUID APPLIED MEMBRANE AIR BARRIER
-GYPSUM SHEATHING BOARD
- 6" COLD FORMED METAL FRAMING
- BATT INSULATION (R-19)
- 5/8" GYPSUM BOARD
1'-6"
8" 10"
AE-602
F4
AE-602
C4
AE-352
F3
AE-602
F4
AE-602
C4
AE-352
D3
AE-352
F9
10"
ALUMINUM CURTAINWALL
WINDOW WITH INSULATED
GLAZING UNITS
CAST STONE SILL
CAST STONE HEADER
SCHEDULED
CEILING
CAST STONE HEADER
5"
6" METAL STUDS
AT 16" OC
CLIP STUD OFF
STEEL BEAM
A8
BEYOND
SCHEDULED
CEILING
DOWNSPOUT
TO CONCRETE
SPLASH BLOCK
(BELOW)
CONTINUOUS
GUTTER
UPPER ROOF
BEARING
20' - 6"
1/4" / FT MIN SLOPE
A
FIRST FLOOR
0"
TPO MEMBRANE SYSTEM OVER
RIGID BOARD INSULATION ON
METAL DECKING
CONCRETE SLAB ON
GRADE- REFER TO
STRUCTURAL
CONCRETE FOOTER-
REFER TO STRUCTURAL
STEEL BEAM- REFER
TO STRUCTURAL
FINISHED GRADE -
SEE CIVIL
SCHEDULED CEILING
AE-352
F1
AE-352
A5
1'-6"
10" 8"
OH
CONTINUOUS GUTTER
AND DOWNSPOUT
PARAPET BEYOND
COPING BEYOND
1"
1"
4 5/8"
5/
8"
SAND BLAST
FINISH
DRIP EDGE
CAST STONE HEADER
1"
1"
4 5/8"
5/
8"
CAST STONE SILL / BANDING
SAND BLAST FINISH
5/
8"
3 5/8"
8"
1' -6
COLD FORMED METAL FRAMING
STUD AT EACH ANCHOR
COLUMN LINE (SEE PLAN)
CAST STONE VENEER
CAST STONE ANCHOR
FACE BRICK VENEER
FACE BRICK ANCHOR
SEALANT AND PREFORMED
COMPRESSIBLE JOINT FILLER
1/2"
8"
1' -6
COLD FORMED METAL FRAMING
STUD AT EACH ANCHOR
COLUMN LINE (SEE PLAN)
FACE BRICK VENEER
FACE BRICK ANCHOR
SEALANT AND PREFORMED
COMPRESSIBLE JOINT FILLER
3/8"FACE BRICK VENEER
FACE BRICK ANCHOR
A
10" 8"
1'-6"
1' -6
AIR SPACE
2" RIGID FIBER
INSULATION
GYPSUM SHEATHING
BOARD
FLUID APPLIED AIR
BARRIER
FACE BRICK
CONTINUOUS GUTTER
WITH HANGERS
TPO ROOF MEMBRANE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FINAL CONSTRUCTION
DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultants:
C rv t\
\V A
M C
E Y
E C
L
IN
IC
A
C E
N T
R A
L s te p h e n
.n u tt a ll2
Z U
K .r v t
/9
/2
:2
:2
P M
AE-351
EXTERIOR WALL SECTIONS
Charlotte Engineers, LLP
5838 Monroe Road
Charlotte, NC 28212
(704) 531-3000
Michael Eaves
HDR Architecture, INC
440 South Church Street, Suite 1000
Charlotte, NC 28202
(704) 338-6844
Nicholas Nash
EYE CLINIC CENTER
WJBD VAMC - COLUMBIA, SC 29209
544-329
05/12/2022 NN RB
1/2" = 1'-0" F1
WALL SECTION - TYPICAL
1/2" = 1'-0"
F8
WALL SECTION - LOBBY
1/2" = 1'-0" F6
WALL SECTION - ENTRANCE
1 2 42 0
1/2" = 1'-0" F2
WALL SECTION - PUNCHED WINDOW
1/2" = 1'-0"
F4
WALL SECTION - WAITING ROOM
1/2" = 1'-0" F9
WALL SECTION - GUTTER END
3" = 1'-0" B1
CAST STONE TRIM PROFILES
3" = 1'-0"
B2
TYPICAL CAST STONE UNIT
3" = 1'-0" B4
CAST STONE - BRICK CONTROL JOINT
3" = 1'-0"
B6
BRICK CONTROL JOINT
1 1/2" = 1'-0" B8
BRICK PARAPET PLAN DETAIL
ALUMINUM CURTAIN WALL SYSTEM
BACKER ROD AND SEALANT
SITE PAVING
SLOPE AWAY FROM BUILDING -
SEE CIVIL
CONCRETE FOOTER
SEE STRUCTURAL
SHIM SPACE AS REQUIRED - FILL
WITH SPRAY FOAM INSULATION -
TYPICAL
STAINLESS STEEL FLASHING
WITH END DAMS
8" M
IN
CONCRETE SLAB WITH
1/2" CHAMFERED EDGE
SEE STRUCTURAL
DAMP PROOFING
GRANULAR FILL - SEE
STRUCTURAL
E
ROOF (DECK
BEARING)
14' - 6"
SLOPE
(2) LAYERS 3/4" PRESSURE -
TREATED PLYWOOD
SHEET METAL COPING
ANCHOR CLIP
COMPRESSIBLE JOINT FILLER
12 GA GALV PLATE FULL
WIDTH OF PLYWOOD
PRESSURE TREATED WOOD BLOCKING
AIR SPACE
2" RIGID FIBER INSULATION
GYPSUM SHEATHING
BOARD
FLUID APPLIED AIR BARRIER
FACE BRICK
5/8" PRESSURE TREATED PLYWOOD
1/2" GYPSUM COVER BOARD
CONTINUOUS RIGID INSULATION
(R-23.6)
PRESSURE TREATED BLOCKING
HEAD JOINT CAVITY VENT
@ 16" OC MAX
5/8" GYPSUM BOARD
ROOF SHEATHING
METAL ROOF DECK -
SEE STRUCTURAL
DEFLECTION CLIP
STEEL BEAM
SEE STRUCTURAL
EXTEND FLUID APPLIED AIR AND WATER BARRIER UP
FACE OF SHEATHING AND OVER BLOCKING.
SEAL TO WALL AIR BARRIER
SELF ADHERING WATERPROOF
MEMBRANE. WRAP OVER PARAPET
SEAL TO WALL AIR BARRIER
1-1/2" RIGID INSULATION
1'-6"
8" 10"
4' -2
TPO ROOF MEMBRANE
E
FIRST FLOOR
0"
1'-6"
GROUT SOLID
FINISHED GRADE-
REFER TO CIVIL
WEEPS @ 16" OC MAX
THRU-WALL FLASHING
FACE BRICK
FLUID APPLIED AIR BARRIER
WALL TIES @ 16" OC VERTICALLY
AND 24" OC HORIZONTALLY
AIR SPACE
2" RIGID FIBER INSULATION
HEAD JOINT CAVITY VENT @ 24" OC MAX
TERMINATION BAR
STAINLESS STEEL DRIP LEG
SEALANT
FLEXIBLE TRANSITION MEMBRANE
DAMP PROOFING
6" COLD FORMED
METAL FRAMING
BATT INSULATION
GYPSUM SHEATHING
BOARD
5/8" GYPSUM BOARD
CONCRETE SLAB
SEE STRUCTURAL
8" 10"
1' -4
A
10" 8"
1'-6"
AIR SPACE
2" RIGID FIBER INSULATION
GYPSUM SHEATHING BOARD
FLUID APPLIED AIR BARRIER
FACE BRICK
STEEL BEAM
SEE STRUCTURAL
BAR JOISTS
SEE STRUCTURAL
HANGING GUTTER - CONTINUOUS
(9" WIDE X 6-3/4" TALL - MIN)
TPO ROOF MEMBRANE
1/2" GYPSUM COVER BOARD
CONTINUOUS RIGID INSULATION
(R-23.6)
5/8"…