This document contains construction plans and specifications for a federal contract solicitation to build a fire operations center. The solicitation seeks proposals to construct a warehouse structure located at 1170 Nursery Road in Wellston, Michigan for the Huron-Manistee National Forest. The project is expected to start before August 1st, 2023. A single-award firm fixed-price contract will be awarded following a competitive source selection conducted according to FAR Parts 15 and 36.
View the file
Other files for this federal contract opportunity
Show all 38
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
EL. 101.5'
T.O. OF SLAB
H E
E L
2'-6"
EXTERIOR WALL SECTION
SCALE:
" = 1'-0"
M I N
TRUSS BEARING
EL. 116.5'
T.O. PLATE
A1-01
FIRST FLOOR
EL. 101.5'
T.O. OF SLAB
H E
E L
2'-6"
EXTERIOR WALL SECTION @ GARAGE
SCALE:
" = 1'-0"
M I N
TRUSS BEARING
EL. 116.5'
T.O. PLATE
A1-01
2SEPARATION WALL SECTION - 1 HR RATED
SCALE:
" = 1'-0"
A1-01
TRUSS BEARING
EL. 116.5'
T.O. PLATE
FIRST FLOOR
EL. 101.5'
T.O. OF SLAB
1-HOUR FIRE SEPARATION WALL ASSEMBLY:
2X4 WOOD STUDS @ 16" O.C.
5/8" TYPE X GYPSUM BOARD ON ASSEMBLY
SIDE AND INTERIOR TYPE GLASS-MAT-FACED
TYPE X GYPSUM BOARD ON GARAGE SIDE.
3 1/2" THICK FIBERGLASS BATT INSULATION.
REINFORCED CONCRETE FOUNDATION
WALL (SEE STRUCTURAL)
CONCRETE SLAB ON 10 MIL. VAPOR
BARRIER ON GRAVEL FILL COMPACTED
TO 95% DENSITY (SEE STRUCTURAL)
EXPANSION JOINT
CONCRETE SLAB ON GRAVEL
FILL COMPACTED TO 95%
DENSITY (SEE STRUCTURAL).
1 LAYER OF 5/8" GLASS-MAT GYPSUM
BOARD ATTACHED TO 1/2" RESILIENT
FURRING CHANNELS SCREW FASTENEND
PERPENDICULAR TO LOWER CHORD OF
WOOD ROOF TRUSSES. (SEE STRUCTURAL).
2X8 PRESSURE TREATED PLATE
ON NEOPRENE SILL SEALER W/ ANCHOR
BOLTS (SEE STRUCTURAL NOTES).
EXISTING GRAD - SLOPE AWAY
FROM BUILDING.
REINFORCED CONCRETE
FOUNDATION WALL (SEE
STRUCTURAL)
ROOF INSULATION: (R-49) 14"
LOOSE-FILL CELLULOS
INSULATION
1X6 ENGINEERED WOOD TRIM
ON 1X WOOD BLOCKING.
WOOD BLOCKING (SEE
STRUCTURAL). NOTCH AT TOP
TO PROVIDE 2" CONTINUOUS
CLEAR VENT SPACE.
1/2" APA RATED EXTERIOR
PLYWOOD SHEATHING SOFFIT
ON 2X6 TOP TRUSS CHORD W/
CONTINUOUS 2" SCREENED
EAVE VENT.
PRE-MANUFACTURED ROOF
TRUSSES (SEE STRUCTURAL).
PROVIDE A TIE-DOWN CLIP
AT EACH TRUSS.
DIMENSIONAL ROOF ASPHALT
SHINGLES ON SYNTHETIC
UNDERLAYMENT AND
" APA
RATED EXTERIOR PLYWOOD
SHEATHING.
ICE AND WATER SHIELD 24"
INSIDE THE EXTERIOR WALL
LINE OF THE BUILDING.
ALUMINUM DRIP EDGE
1X4 ENGINEERED WOOD TRIM
ON 1X6 ENGINEERED WOOD
TRIM AND 2X6 SUB-FASCIA
(TYPICAL) TO MATCH TRUSSES
" APA RATED EXTERIOR PLYWOOD
SHEATHING SOFFIT ON 2X6 TOP
TRUSS CHORD W/ CONTINUOUS
2" SCREENED EAVE VENT.
PRE-MANUFACTURED ROOF
TRUSSES (SEE STRUCTURAL).
PROVIDE A TIE-DOWN CLIP
AT EACH TRUSS.
ROOF SHINGLES ON SYNTHETIC
UNDERLAYMENT AND
" APA
RATED EXTERIOR PLYWOOD
SHEATHING.
ICE AND WATER SHIELD 24"
INSIDE THE EXTERIOR WALL
LINE OF THE BUILDING.
ALUMINUM DRIP EDGE
1X4 ENGINEERED WOOD TRIM
ON 1X6 ENGINEERED WOOD
TRIM AND 2X6 SUB-FASCIA
(TYPICAL) TO MATCH TRUSSES
EXTERIOR WALL ASSEMBLY:
● ENGINEERED WOOD LAP SIDING,
6" EXPOSURE
● "HYDROGAP" DRAINABLE
HOUSEWRAP OR APPROVED
EQUAL.
1" POLYISO RIGID CONTINUOUS
INSULATION (R-6).
● 1/2" EXTERIOR GRADE PLYWOOD
SHEATHING
● 2X8 WOOD STUDS @ 16" O.C.
DURA-SKRIM
10HUV OR
APPROVED EQUAL VAPOR
RETARDER AND AIR BARRIER
5/8" GYPSUM BOARD INTERIOR
FINISH.
WALL INSULATION: 6" UNFACED
BATT INSULATION - (R21)
ROOF INSULATION: (R-49) 14"
LOOSE FILL CELLULOSE
INSULATION.
1X6 ENGINEERED WOOD TRIM ON
1X WOOD BLOCKING
CONCRETE SLAB OVER DURA-
SKRIM
10HUV OR APPROVED
EQUAL VAPOR RETARDER ON
GRAVEL FILL COMPACTED TO
95% DENSITY (SEE STRUCTURAL).
2X8 PRESSURE TREATED PLATE
ON SILL SEALER W/ ANCHOR
BOLTS (SEE STRUCTURAL NOTES).
EXISTING GRADE - SLOPE AWAY
FROM BUILDING.
REINFORCED CONCRETE
FOUNDATION WALL (SEE
STRUCTURAL)
2" XPS RIGID INSULATION DOWN TO
FOOTING WITH NUDO "FIBERLITE
FRP PANEL OR APPROVED EQUAL
GLUED TO INSULATION FROM TOP
OF FOUNDATION WALL TO 12"
BELOW GRADE LINE.
1 LAYER OF 5/8" GYPSUM BOARD ATTACHED
TO 1/2" RESILIENT FURRING CHANNELS SCREW FASTENED
PERPENDICULAR TO LOWER CHORD OF WOOD ROOF
TRUSSES (SEE STRUCTURAL).
SCALE: 3/4" = 1'-0"
8" 1'-4"0 2'-8"
1/2" NOMACO "NOMAFLEX" JOINT
FILLER OR APPROVED EQUAL.
CONCRETE SLAB OVER DURA-
SKRIM
10HUV OR APPROVED
EQUAL VAPOR RETARDER ON
GRAVEL FILL COMPACTED TO
95% DENSITY (SEE STRUCTURAL).
1/2"NOMACO "NOMAFLEX" JOINT
FILLER OR APPROVED EQUAL.
2" XPS RIGID INSULATION DOWN TO
FOOTING WITH NUDO "FIBERLITE
FRP PANEL OR APPROVED EQUAL
GLUED TO INSULATION FROM TOP
OF FOUNDATION WALL TO 12"
BELOW GRADE LINE.
DURA-SKRIM
10HUV OR
APPROVED EQUAL VAPOR
RETARDER & AIR BARRIER.
1 LAYER OF 5/8" GLAS-MAT
GYPSUM BOARD ATTACHED
TO 1/2" RESILIENT FURRING
CHANNELS SCREW FASTENED
PERPENDICULAR TO LOWER
CHORD OF WOOD ROOF
TRUSSES (SEE STRUCTURAL).
DURA-SKRIM
10HUV OR
APPROVED EQUAL VAPOR
RETARDER & AIR BARRIER.
1 LAYER OF 5/8" GYPSUM
BOARD ATTACHED TO 1/2"
RESILIENT FURRING
CHANNELS SCREW FASTENED
PERPENDICULAR TO LOWER
CHORD OF WOOD ROOF
TRUSSES (SEE STRUCTURAL).
6", 20 GAUGE HALF
ROUND GALVALUME
COATED GUTTER
6", 20 GAUGE HALF
ROUND GALVALUME
COATED GUTTER
SUSPENDED TILE CEILING ASSEMBLY W/ METAL GRID
AND SUPPORTS (SEE ROOM FINISH SCHEDULE).
OPTIONAL BID ITEM.
LAY-IN CEILING TILE
EL. 110.5'
BOTTOM OF
GARAGE SIDE ASSEMBLY SIDE
5/8" GLAS-MAT GYPSUM BOARD
WALL FINISH (SEE ROOM FINISH
SCHEDULE).
SUSPENDED TILE CEILING
ASSEMBLY W/ METAL GRID
AND SUPPORTS (SEE ROOM
FINISH SCHEDULE). OPTIONAL
BID ITEM
LAY-IN CEILING TILE
EL. 110.5'
BOTTOM OF
A4-02
SIMILAR
A4-02
A4-02
A4-02
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
/22
/22
:1 2 B
GU
ER
RE
RA
C :\U
SE
RS
\B
GU
ER
RE
RA
\D
OC
UM
EN
TS
\22
C
AD
IL
LA
C-
MA
NI
ST
EE
W
AR
EH
OU
SE
-G
AR
AG
E\
FI
NA
L
SU
BM
IS
SI
ON
P
AC
KA
GE
_2
2-
\C
AD
F
IL
ES
-N
AM
IN
G
CO
NV
EN
TI
ON
\09
-A
BL
-0
2-
A4
.D W
G;
R9
EASTERN REGION
FINAL SUBMISSION 11/18/2022
CADILLAC-MANISTEE
FIRE OPERATIONS
CENTER
HURON-MANISTEE
NATIONAL FOREST
CADILLAC-MANISTEE RANGER
DISTRICT
WALL SECTIONS
11/18/2022 090403-ABL2022-0002-A417
B.GUERRERA
B.GUERRERA
D.DEAN/M.TENDLER
A4-01 17 60
AutoCAD SHX Text ENGINEERED WOOD LAP SIDING, 2X8 WOOD STUDS @ 16" O.C. DURA-SKRIM® 10HUV OR 10HUV OR 5/8" GYPSUM BOARD INTERIOR
AutoCAD SHX Text
10HUV OR APPROVED
AutoCAD SHX Text
10HUV OR APPROVED
AutoCAD SHX Text
10HUV OR
AutoCAD SHX Text
10HUV OR
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
| Sheets and Views |
| A401-Wall Sections |
File details come from the government source that posted it. Updated .