220063_01_230601_DRAWINGS.pdf

PDF 2 MB Posted

Attached to
Huron Manistee NF Construct Cadillac-Manistee Fire Ops Center Federal contract opportunity
Solicitation number
12445523R0018
Issued by
Department of Agriculture Forest Service

About this file

This document package includes construction drawings and a federal contract opportunity notice. The drawings depict demolition plans for an existing staff house to make way for a new Cadillac-Manistee Fire Operations Center. The project involves removing all structures and underground utilities, backfilling, and protecting nearby septic and drainage infrastructure. The related solicitation is for construction of a new warehouse facility at the site to house fire operations. The single-award firm-fixed-price contract will be awarded by the US Department of Agriculture Forest Service with an expected start date before August 1, 2023. The opportunity is being conducted according to FAR Parts 15 and 36. No further details are provided on response dates, pricing terms, or incumbent contractors.

View the file

Other files for this federal contract opportunity

Other files attached to Huron Manistee NF Construct Cadillac-Manistee Fire Ops Center, newest first.
File Type Posted
Decom Staff Office P7290030.JPG JPG image
Decom Staff Office Page 57 from Report.pdf PDF
Decom Staff Office Page 242 from Report.pdf PDF
Decom Staff Office P7290031.JPG JPG image
Decom Staff Office P7290025.JPG JPG image
Decom Staff Office P7290024.JPG JPG image
RFI log for Q and A 6-30-2023 FINAL.xlsx XLSX spreadsheet
099723 Concrete Sealer.pdf PDF
090403-ABL2022-0002-A421-A405 INTERI0R SIGN ELEVATIONS_REV01.pdf PDF
095123 Acoustical Tile Ceilings.DOC DOC document
RFI log for Q and A 6-28-2023.xlsx XLSX spreadsheet
Sol_12445523R0018_Amd_0003.pdf PDF
RFI log for Q and A 6-27-2023.xlsx XLSX spreadsheet
220063_STAFFHOUSE_TABLE OF CONTENTS and SPECS.pdf PDF
Sign-in sheet.pdf PDF
329200 SEEDING and MULCHING.pdf PDF
RFI log for Q and A.xlsx XLSX spreadsheet
323113 Chain Link Fences and Gates.doc DOC document
090403-ABL2022-0002-A626-SCHEDULES_REV03.pdf PDF
Sol_12445523R0018_Amd_0002.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV03.pdf PDF
QandA 6-9-23.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV02.pdf PDF
Sol_12445523R0018_Amd_0001.pdf PDF
ATT1 SOI CM Fire Ops Center.pdf PDF
ATT1 SOI CM Fire Ops Center.xlsx XLSX spreadsheet
ATT3 2022-HM-CADILLAC-MANISTEE FIRE OPERATIONS CENTER-CD FINAL SUBMISSION v.02.pdf PDF
ATT9 C1-02_New Fire House Geometric Plan-REV01.pdf PDF
ATT11 C5-17 SEPTIC and WATER SYSTEM DETAILS-REV-001.pdf PDF
ATT5 090403-ABL2022-0002-A417-A401-WALL SECTIONS_REV01.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV01.pdf PDF
ATT4 090403-ABL2022-0002-A214-EXTERIOR ELEVATION_REV01.pdf PDF
ATT6 090403-ABL2022-0002-A419-A403 INTERIOR ELEVATIONS_REV01.pdf PDF
ATT8 090403-ABL2022-0002-A626-SCHEDULES_REV02.pdf PDF
Sol_12445523R0018.pdf PDF
ATT7 090403-ABL2022-0002-A420-A404 INTERIOR ELEVATION_REV02.pdf PDF
ATT10 C1-16 SEPTIC DRAINFIELD and SEPTIC TANK-REV01.pdf PDF
ATT12 Wage Determination MI20230134.pdf PDF
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET OF

Imagery Date: 6/21/2022

VICINITY MAP

PROJECT LOCATION

TRAVEL DIRECTIONS:

THE CHITTENDEN NURSERY SITE IS LOCATED APPROXIMATELY 6.5 MILES WEST OF

THE INTERSECTION OF ROUTE 55 & ROUTE 37.

United States Department of Agriculture Forest Service

(R09) EASTERN REGION

HURON-MANISTEE NATIONAL FORESTS

MANISTEE COUNTY

MICHIGAN

RECOMMENDED BY:

APPROVED:

FOREST ENGINEER

DISTRICT RANGER

FOREST SUPERVISOR

RO FACILITIES PROGRAM MANAGER

DIRECTOR OF ENGINEERING

DATE

DATE

DATE

DATE

DATE

6/1 /20

5:

:1

8 P M

C:

\R ev it\

\22

_0

1_ A_ m el.

na pp i.r vt

CADILLAC-MANISTEE FIRE OPERATIONS CENTER -

DEMOLISH STAFF HOUSE

1 3

INDEX OF SHEETS

SHEET SHEET TITLE DATE

G-1 COVER SHEET 06/01/2023

A-01 ARCHITECTURAL SYMBOLS, AND ABBREVIATIONS 06/01/2023

AD1 DEMOLITION PLAN 06/01/2023

DRAWING REFERENCE SYMBOLS

ENLARGED PLAN OR DETAIL

WALL SECTION

X-###

X

X

X-###

BUILDING SECTION

EXTERIOR ELEVATIONS

INTERIOR ELEVATIONS

DEMO KEYNOTE##

REVISION CLOUD AND TAG

VIEW TITLE & REFERENCE

EXISTING COLUMN LINE

NEW COLUMN LINE

DETAIL

LEVEL OR ELEVATION

XX

DEMARCATION LINE

X-###

X-###

X-###

X-###

X-###

X-###

X## EQUIPMENT TAG

WALL TAG

###.# DOOR TAG

ROOM NAME

ROOM TAG

WINDOW TAG

X#

## ARCHITECTURAL KEYNOTE

#' - #" CEILING SPOT ELEVATION

XX# FURNITURE TAG

FINISH TAG

SPECIALITY EQUIPMENT TAG

XX-#

XX- #

ABBREV. FULL TEXT

AB ANCHOR BOLT

ABI ADDITIVE BID ITEM

AC ACOUSTICAL

ACB ACOUSTICAL CEILING BAFFLE

ACP ACOUSTICAL CEILING PANEL

ACS ACOUSTICAL CEILING SPRAY

AD AREA DRAIN

ADA ADA

AFF ABOVE FINISHED FLOOR

AL ALUMINUM

ALUM ALUMINUM

AP ACCESS DOORS

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASPH ASPHALT

AWP ACOUSTICAL WALL PANEL

B/ BOTTOM OF

BD BOARD

BF BARRIER FREE

BIT BITUMINOUS

BL BUILDING LINE

BLDG BUILDING

BLKHD BULKHEAD

BOTT BOTTOM

BP BASE PLATE

BR BUMP RAIL

BS BOTH SIDES

BUR BUILT UP ROOFING

CAB CABINET

CB CATCH BASIN

CEM CEMENT

CG CORNER GUARD

CH CHANNEL

CHKDPL CHECKERED PLATE

CJ CONTROL JOINT

CL CENTERLINE

CL TO CL CENTERLINE TO CENTERLINE

CLG CEILING

CLK CAULKING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

ABBREV. FULL TEXT

COMP COMPRESSIBLE

COMPO COMPOSITION

CONC CONCRETE

CONN CONNECT, CONNECTION

CONST CONSTRUCTION

CONST JT CONSTRUCTION JOINT

CONT CONTINUOUS

CONTR CONTRACTOR

CPT CARPET TILE

CS CONCRETE SEALER

CTR COUNTER

CTSK COUNTERSINK

DEXS DOUBLE EXTRA STRONG (STEEL

PIPE)

DF DRINKING FOUNTAIN

DIA DIAMETER

DIFF DIFFUSER

DN DOWN

DO DOOR OPENING

DR DOOR

DS DOWN SPOUT

DT DRAIN TILE

DTL DETAIL

DWG DRAWING

DWR DRAWER

E EAST

EA EACH

EIFS EXTERIOR INSULATION AND FINISH

SYSTEMS

EJ EXPANSION JOINT

EL ELEVATION

ELECT ELECTRICAL

ELEV ELEVATOR OR ELEVATION

ENCL ENCLOSURE

EP EPOXY PAINT

EPS EXTERIOR PAINT SYSTEM

EQ EQUAL

EQUIP EQUIPMENT

ES EXPOSED STRUCTURE

EW EACH WAY

EWC ELECTRICAL WATER COOLER

EX EXISTING

EXGR EXISTING GRADE

ABBREV. FULL TEXT

EXP EXPANSION

EXS EXTRA STRONG (STEEL PIPE)

EXT EXTERIOR

FA FIRE ALARM

FAB FABRIC/UPHOLSTERY

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FG FROSTED GLASS

FHC FIRE HOSE CABINET

FIN FINISH

FL FLOOR

FLL FLOOR LINE

FLUOR FLUORESCENT

FOC FACE OF COLUMN

FOCONC FACE OF CONCRETE

FRC FIBER REINFORCED CONCRETE

FRP FIELD REINFORCED PANEL

FRPFG FIREPROOFING

FS FULL SIZE

FT FIRE TREATED

FTG FOOTING

FUR FURRING

FV FIELD VERIFY

G.B. GRAB BAR, GRADE BEAM

G.O. GRILL OPENING

GA GAUGE

GALV GALVANIZED

GCT GLAZED CERAMIC TILE

GFCI GROUND FAULT CIRCUIT

INTERRUPTER

GL GLASS

GND. GROUND

GR. GRADE

GRTG. GRATING

GSCFT GLAZED STRUCTURAL CLAY

FACING TILE

GT GROUT

GYP. BD. GYPSUM BOARD

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD

HDPB HIGH DENSITY PARTICLEBOARD

ABBREV. FULL TEXT

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HIGH POINT

HR HOUR

HT HEIGHT

HWD HARDWARE

I.D. OR ID INSIDE DIAMETER

I.E. INVERT ELEVATION

IG INSULATING GLASS

IN INCHES

INCL INCLUDING, INCLUSIVE

INSUL INSULATION

INT INTERIOR

IPS INTERIOR PAINT SYSTEM

JAN JANITOR

JT JOINT

kW KILOWATTS kWh KILOWATT HOURS

LAD LADDER

LAM LAMINATED

LAV LAVATORY

LF LINEAR FEET

LGTH LENGTH

LH LEFT HAND

LKR LOCKER

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LO LOUVER OPENING

LP LIGHTING PANEL

LPG LIQUID PETROLEUM GAS

LPS LOW PRESSURE STEAM

LT LIGHT

LWT LEAVING WATER TEMPERATURE

MA MEDICAL AIR

MANUF MANUFACTURER

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MBH THOUSAND BTU/HR

MC MEDICINE CABINET

MCA MINIMUM CIRCUIT AMPACITY

MCC MULTI-COLOR COATING

MDO MEDIUM DENSITY OVERLAY

ABBREV. FULL TEXT

MECH MECHANICAL

MEMBWP MEMBRANE WATERPROOFING

MET METAL

MEZZ MEZZANINE

MFR MANUFACTURER

MFS MAXIMUM FUSE SIZE

MG MEDICAL GAS

MH MANHOLE

MHP MOTOR HORSEPOWER

MIN. MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MM MISCELLANEOUS METALS

MO MASONRY OPENING

MOCP MAXIMUM OVERCRRENT

PROTECTION

MPC MICHIGAN PLUMBING CODE

MR MANUFACTURER'S

RECOMMENDATIONS

MT MARBLE TILE

MTD MOUNTED

MUL. MULLION

N NORTH

N.S. NEAR SIDE

NF NO FINISH

NIC NOT IN CONTRACT

NO NUMBER

NPSH NET POSITIVE SUCTION HEAD

NSNS NON SHRINK NON STAIN GROUT

NTS NOT TO SCALE

NTS NOT TO SCALE

O.C. OR OC ON CENTER

OBSGL OBSCURE GLASS

OD OUTSIDE DIAMETER

OHDR SECTIONAL OVERHEAD DOOR

OPNG OPENING

OPP OPPOSITE

P PAINT

PART PARTITION

PB PARTICLE BOARD

PC PRECAST

PCS PIECES

PERM PERMANENT

ABBREV. FULL TEXT

PL PLATE

PLAM PLASTIC LAMINATE

PLAS PLASTER

PLBG PLUMBING

PLY PLYWOOD

PT PRESSURE TREATED

PT PORCELAIN TILE

PTB PORCELAIN TILE BASE

QT QUARRY TILE

QTB QUARTZ TILE BASE

QTZ QUARTZ

R RISER

RA RETURN AIR

RB RUBBER BASE

RC ROOF CONDUCTOR

RD ROOF DRAIN

RD ROUND

RECVG RECEIVING

REF REFRIGERATOR

REINF REINFORCED

REQ'D REQUIRED

RF RESILIENT FLOORING

RH RIGHT HAND

RL ROOF LADDER

RM ROOM

RO ROUGH OPENING

RS ROOF SUMP

RSN RESIN

RWD REDWOOD

RWD RIGID WALL PROTECTION

S SOUTH

S SPANDREL GLASS

SA SUPPLY AIR

SAB SOUND ATTENUATION BLANKETS

SC SOLID CORE

SCH SCHEDULE

SCONC SEALED CONCRETE

SCWD SOLID CORE WOOD

SECT SECTION

SER.RECPT SERVICE RECEPTOR

SH SHELF

SHT SHEET

SHWR SHOWER

ABBREV. FULL TEXT

SIM SIMILAR

SLR CONCRETE SEALER

SLS SOLID SURFACE

SLV SHORT LEG VERTICAL

SPEC SPECIFICATION

SQ SQUARE

SQFT SQUARE FOOT

SS STAINLESS STEEL

SSK SERVICE SINK

SSM SOLID SURFACING MATERIAL

ST SMOKE-TIGHT PER CODE TO

RESIST THE PASSAGE OF SMOKE

STD STANDARD

STDW STANDARD WEIGHT (STEEL PIPE)

STL STEEL

STN STAIN

STOR STORAGE

STRL STRUCTURAL

SUPP SUPPORT

SUSP SUSPENDED

SYM SUSPENSION SYMMETRICAL

T TREAD

T&G TONGUE AND GROOVE

T.O.C. OR T/C TOP OF CONCRETE

T.O.F. OR T/F TOP OF FOOTING

T.O.M. OR T/M TOP OF MASONRY

T.O.P. OR T/P TOP OF PAVEMENT

T.O.S. OR T/S TOP OF STEEL

T.O.W. OR T/W TOP OF WALL

T/ TOP OF

TB TRUSS BEARING

TG TEMPERED GLASS

THK THICK

THRESH THRESHOLD

TLT TOILET

TP TOILET PARTITION

TR TRANSITION TRIM

TYP TYPICAL

TYP TYPICAL

UNF UNFINISHED

UNO UNLESS NOTED OTHERWISE

UR URINAL

VCT VINYL COMPOSITION TILE

ABBREV. FULL TEXT

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

W WEST

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WC WALLCOVERING

WCO WALL CLEAN OUT

WCVR WALLCOVERING

WD WOOD

WP WATERPROOFING

WP WORKPOINT

WP WALL PROTECTION

WS WINDOW SHADE

WSCT WAINSCOT

WT WEIGHT

X-(MATERIAL) DENOTES EXISTING MATERIAL

REFRENCED

DRAWING SHEET NO.

DATE

PROJECT NO.

PROJECT NAME

DRAWING TITLE

ARCHIVE NO.

DESIGNER

DRAWN

CHECKED

STAMPS, LOGOS, AND SEALS

United States Department of Agriculture Forest Service

(R09)

EASTERN REGION

SHEET OF

6/1 /20

5:

:1

8 P M

C:

\R ev it\

\22

_0

1_ A_ m el.

na pp i.r vt

CADILLAC-MANISTEE

FIRE OPERATIONS

CENTER -

DEMOLISH STAFF

HOUSE

A-01 04/18/2023

220063-01

MB

KJH

KJH

ARCHITECTURAL

SYMBOLS, AND

ABBREVIATIONS

HURON-MANISTEE

NATIONAL FORESTS

CADILLAC-MANISTEE

RANGER STATION

2 3

NO. REVISION/ ISSUE DATE

D1 D3 D4

D2

W W

W W

W W

W W

W

EXISTING SIDEWALK

TO REMAIN

APPROXIMATE LOCATIONS OF

EXISTING SEPTIC TANK ACCESS LIDS

APPROXIMATE LOCATION OF EXISTING CLEANOUT

EXISTING UTILITY

POLE TO REMAIN

EXISTING

COMMUNICATIONS

UTILITY BOX TO

REMAIN

NU

RS

ER

Y

RO

AD

W W

W W

C

OE

OE

OE

OE

OE

C

C

C

C

EXISTING LP TANK

TO REMAIN

D5

D7

D2

D2

S

S

APPROXIMATE LOCATION OF

SEPTIC TANK UNDERGROUND

G G

G G

D2 D6

APPROXIMATE LOCATION OF

DRAIN FIELD. PROTECT THIS

AREA FROM VEHICLE TRAFFIC.

D8

DEMO PLAN LEGEND:

EXISTING WALL

OR PARTITION TO

REMAIN

EXISTING DOOR

TO REMAIN

EXISTING

BUILDING

COMPONENT &

STRUCTURE TO

REMAIN

EXISTING

WALL/PARTITION OR

EXISTING ITEMS TO

BE REMOVED

EXISTING DOOR &

FRAME TO BE

REMOVED

EXISTING ASSEMBLY

TO BE REMOVED

NOTE: ALL ITEMS

SHOWN RED AND

DASHED ARE TO BE

DEMOLISHED- U.N.O.

GENERAL DEMOLITION NOTES:

1. ALL EXISTING ITEMS TO BE RETAINED BY THE OWNER WILL BE REMOVED PRIOR

TO DEMOLITION. ANY ITEMS LEFT IN THE DEMOLITION AREA BECOME THE

PROPERTY OF THE DEMOLITION SUBCONTRACTOR.

2. CONTRACTOR AND SUBCONTRACTORS SHALL VISIT THE SITE PRIOR TO

SUBMITTING A BID TO BECOME FAMILIAR WITH EXISTING CONDITIONS

3. CONTRACTOR AND DEMOLITION SUBCONTRACTOR TO COORDINATE

DEMOLITION WORK WITH COR PRIOR TO START OF WORK.

4. THE INFORMATION CONTAINED ON THESE DRAWINGS PERTAINING TO EXISTING

CONDITIONS, SUCH AS BUT NOT LIMITED TO, UTILITIES, AND TOPOGRAPHY IS

FURNISHED SOLELY AS THE BEST INFORMATION AVAILABLE, ITS ACCURACY IS

NOT GUARANTEED AND IS CONSIDERED "INCOMPLETE". THE USE OF THIS

INFORMATION DOES NOT PROVIDE THE CONTRACTOR RELIEF FROM ANY

RESPONSIBILITY FOR DAMAGES DUE TO ANY INACCURACIES.

5. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING ALL EXISTING

UNDERGROUND UTILITIES USING INDUSTRY STANDARD UTILITY LOCATING

EQUIPMENT OR A THIRD PARTY PRIVATE UTILITY LOCATING COMPANY.

EXISTING LOCATIONS TO BE DOCUMENTATED AND SUBMITTED TO THE COR FOR

THEIR RECORD.

6. SOME EXISTING MATERIALS HAVE BEEN PREVIOUSLY TESTED AND CONTAIN

ASBESTOS. CONTRACTOR IS RESPONSIBLE FOR PROPERLY REMOVING AND

DISPOSING OF THESE MATERIALS. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

7. SOME EXISTING MATERIALS HAVE BEEN PREVIOUSLY TESTED AND CONTAIN

LEAD PAINT. CONTRACTOR IS RESPONSIBLE FOR PROPERLY REMOVING AND

DISPOSING OF THESE MATERIALS. REFER TO SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

1/8" = 1'-0"

DEMOLITION PLAN

DEMOLITION KEY

KEY VALUE KEYNOTE TEXT

D1 REMOVE BUILDING IN ITS ENTIRETY UNLESS OTHERWIDE NOTED,

INCLUDING ALL SUB-GRADE CONSTRUCTION. FILL REMOVAL WITH

SATISIFACTORY SOILS AND TOP SOIL AS REQUIRED.

D2 REMOVE UTILITY BACK TO SOURCE. CUT AND CAP ANY PIPING. FILL

REMOVAL WITH SATISIFACTORY SOILS AND TOP SOIL AS REQUIRED.

D3 REMOVE CONCRETE SIDEWALK IN ITS ENTIRETY. FILL REMOVAL WITH

SATISIFACTORY SOILS AND TOP SOIL AS REQUIRED.

D4 PATCH AND REPAIR EDGE OF SIDEWALK TO REMAIN TO PROVIDE A

SMOOTH, FINISHED EDGE TO MATCH EXISTING.

D5 REMOVE CONCRETE STOOP. FILL REMOVAL WITH SATISIFACTORY SOILS

AND TOP SOIL AS REQUIRED.

D6 RELOCATE EXISTING CLEAN OUT TO BE CLOSER TO EXISTING SEPTIC

TANK. REMOVE SANITARY LINE BETWEEN BUILDING AND NEW CLEANOUT

LOCATION, CAP UNDERGROUND FOR POTENTIAL FUTURE USE.

D7 REMOVE, SALVAGE AND RETURN CONDENSOR TO OWNER FOR THEIR

USE. REMOVE ALL ASSOCIATED PIPING AND WIRING AS PART OF THE

BUILDING DEMO.

D8 REMOVE CONCRETE PAD IN ITS ENTIRETY. FILL REMOVAL WITH

SATISIFACTORY SOILS AND TOP SOIL AS REQUIRED.

DRAWING SHEET NO.

DATE

PROJECT NO.

PROJECT NAME

DRAWING TITLE

ARCHIVE NO.

DESIGNER

DRAWN

CHECKED

STAMPS, LOGOS, AND SEALS

United States Department of Agriculture Forest Service

(R09)

EASTERN REGION

SHEET OF

6/1 /20

5:

:1

8 P M

C:

\R ev it\

\22

_0

1_ A_ m el.

na pp i.r vt

CADILLAC-MANISTEE

FIRE OPERATIONS

CENTER -

DEMOLISH STAFF

HOUSE

AD1

04/18/2023

220063-01

MB

KJH

KJH

DEMOLITION PLAN

HURON-MANISTEE

NATIONAL FORESTS

CADILLAC-MANISTEE

RANGER STATION

3 3

NO. REVISION/ ISSUE DATE

2023-06-27T08:34:42-0400
HEATHER JAMISON
2023-06-27T10:17:25-0400
SCOTT PEEDLE

File details come from the government source that posted it. Updated .