ATT4 090403-ABL2022-0002-A214-EXTERIOR ELEVATION_REV01.pdf

PDF 312 KB Posted

Attached to
Huron Manistee NF Construct Cadillac-Manistee Fire Ops Center Federal contract opportunity
Solicitation number
12445523R0018
Issued by
Department of Agriculture Forest Service

About this file

This document provides exterior elevation drawings and details for a federal construction contract solicitation. The solicitation is to construct a new Cadillac-Manistee Fire Operations Center warehouse structure located at 1170 Nursery Road in Wellston, Michigan for the US Department of Agriculture Forest Service. Key details include specifications for dimensional asphalt shingles, engineered wood lap siding and trim, roof vents, gutters and downspouts. The single award firm fixed price contract is expected to begin before August 1, 2023. The solicitation will follow FAR Parts 15 and 36 procedures and the successful offeror will build the warehouse to the specifications in the drawings.

View the file

Other files for this federal contract opportunity

Other files attached to Huron Manistee NF Construct Cadillac-Manistee Fire Ops Center, newest first.
File Type Posted
Decom Staff Office P7290031.JPG JPG image
Decom Staff Office P7290025.JPG JPG image
Decom Staff Office P7290024.JPG JPG image
Decom Staff Office P7290030.JPG JPG image
Decom Staff Office Page 57 from Report.pdf PDF
Decom Staff Office Page 242 from Report.pdf PDF
099723 Concrete Sealer.pdf PDF
RFI log for Q and A 6-30-2023 FINAL.xlsx XLSX spreadsheet
095123 Acoustical Tile Ceilings.DOC DOC document
090403-ABL2022-0002-A421-A405 INTERI0R SIGN ELEVATIONS_REV01.pdf PDF
RFI log for Q and A 6-28-2023.xlsx XLSX spreadsheet
RFI log for Q and A 6-27-2023.xlsx XLSX spreadsheet
220063_01_230601_DRAWINGS.pdf PDF
220063_STAFFHOUSE_TABLE OF CONTENTS and SPECS.pdf PDF
Sol_12445523R0018_Amd_0003.pdf PDF
RFI log for Q and A.xlsx XLSX spreadsheet
323113 Chain Link Fences and Gates.doc DOC document
090403-ABL2022-0002-A626-SCHEDULES_REV03.pdf PDF
Sign-in sheet.pdf PDF
329200 SEEDING and MULCHING.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV03.pdf PDF
QandA 6-9-23.pdf PDF
Sol_12445523R0018_Amd_0002.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV02.pdf PDF
Sol_12445523R0018_Amd_0001.pdf PDF
ATT3 2022-HM-CADILLAC-MANISTEE FIRE OPERATIONS CENTER-CD FINAL SUBMISSION v.02.pdf PDF
ATT9 C1-02_New Fire House Geometric Plan-REV01.pdf PDF
ATT11 C5-17 SEPTIC and WATER SYSTEM DETAILS-REV-001.pdf PDF
ATT5 090403-ABL2022-0002-A417-A401-WALL SECTIONS_REV01.pdf PDF
ATT2 CADILLAC-MANISTEE FIRE OPERATIONS CENTER_SPECIFICATIONS_FINAL SUBMISSION_REV01.pdf PDF
ATT6 090403-ABL2022-0002-A419-A403 INTERIOR ELEVATIONS_REV01.pdf PDF
ATT8 090403-ABL2022-0002-A626-SCHEDULES_REV02.pdf PDF
Sol_12445523R0018.pdf PDF
ATT7 090403-ABL2022-0002-A420-A404 INTERIOR ELEVATION_REV02.pdf PDF
ATT10 C1-16 SEPTIC DRAINFIELD and SEPTIC TANK-REV01.pdf PDF
ATT12 Wage Determination MI20230134.pdf PDF
ATT1 SOI CM Fire Ops Center.pdf PDF
ATT1 SOI CM Fire Ops Center.xlsx XLSX spreadsheet
Show all 38

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SCALE: 1/8" = 1'-0"

E A S T E L E V A T I O N

SCALE: 1/8" = 1'-0"

W E S T E L E V A T I O N

SCALE: 1/8" = 1'-0"

S O U T H E L E V A T I O N

SCALE: 1/8" = 1'-0"

N O R T H E L E V A T I O N

GABLE LOUVERED VENT

GABLE LOUVERED VENT

RIDGE VENT

DIMENSIONAL ASPHALT

SHINGLES W/ A SOLAR

REFLECTANCE INDEX (SRI)

OF 29 OR HIGHER

ENGINEERED WOOD

LAP SIDING AND TRIM W/

6" EXPOSURE

ENGINEERED WOOD

LAP SIDING AND TRIM

W/ 6" EXPOSURE

ENGINEERED WOOD

LAP SIDING AND TRIM

W/ 6" EXPOSURE

ENGINEERED WOOD

LAP SIDING AND TRIM

W/ 6" EXPOSURE

FIRST FLOOR

EL. 101.5'

T.O. SLAB

TRUSS BEARING

EL. 116.5'

T.O. PLATE

RIDGE VENT

DIMENSIONAL ASPHALT

SHINGLES W/ A SOLAR

REFLECTANCE INDEX (SRI)

OF 29 OR HIGHER

FIRST FLOOR

EL. 101.5'

T.O. SLAB

TRUSS BEARING

EL. 116.5'

T.O. PLATE

FIRST FLOOR

EL. 101.5'

T.O. SLAB

TRUSS BEARING

EL. 116.5'

T.O. PLATE

FIRST FLOOR

EL. 101.5'

T.O. SLAB

TRUSS BEARING

EL. 116.5'

T.O. PLATE

GRADE LINE GRADE LINE

GRADE LINE

GRADE LINE

BOLLARD (TYPICAL)

A5-01

A5-01

A5-01

A5-01

A5-03

A5-03

A3-01

A

A3-01

A

A3-01

B

A3-01

B

A3-01

A

A3-01

A

A3-01

B

A3-01

B

BOTTOM OF CEILING

EL. 110.5'

OF CEILING

EL. 110.5'

BOTTOM

EMERGENCY

EXIT

EMERGENCY

EXIT

RIDGE VENT

EMERGENCY

EXIT

A

6" HALF ROUND GALVALUME

METAL GUTTER

6" HALF ROUND GALVALUME

METAL GUTTER

4"Ø GALVALUME

METAL DOWNSPOUT.

TYPICAL AT ALL

CORNERS.

4"Ø GALVALUME

METAL DOWNSPOUT

A A A A A A A A A

A A A A

A3-01

A

A3-01

A

A5-04

A3-02

C

A3-02

C

A5-04

A5-03

A5-03

A5-03

A5-03

A5-03

4"Ø GALVALUME

METAL DOWNSPOUT.

TYPICAL AT ALL

CORNERS

4"Ø GALVALUME

METAL DOWNSPOUT.

TYPICAL AT ALL

CORNERS.

6" HALF ROUND

GALVALUME

METAL GUTTER

6" HALF ROUND

GALVALUME METAL

GUTTER

EQ. EQ.

EXHAUST HOODED

WALL CAP.

EQ. EQ.

EXHAUST HOODED

WALL CAP.

EXHAUST HOODED

WALL CAP.

EQ. EQ.

EXHAUST HOODED

WALL CAP.

6'-0"

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.

DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

2/5 /23

:0

5 B

GU

ER

RE

RA

C

:\U

SE

RS

\B

GU

ER

RE

RA

\D

OC

UM

EN

TS

\22

C

AD

IL

LA

C-

MA

NI

ST

EE

W

AR

EH

OU

SE

-G

AR

AG

E\

FI

NA

L

SU

BM

IS

SI

ON

P

AC

KA

GE

_2

2-

\C

AD

F

IL

ES

-N

AM

IN

G

CO

NV

EN

TI

ON

\09

-A

BL

-0

2- A2

.D

W G;

R9

EASTERN REGION

FINAL SUBMISSION 11/18/2022

CADILLAC-MANISTEE

FIRE OPERATIONS

CENTER

HURON-MANISTEE

NATIONAL FOREST

CADILLACE-MANISTER RANGER

DISTRICT

EXTERIOR ELEVATIONS

11/18/2022 090403-ABL2022-0002-A214

B.GUERRERA

B.GUERRERA

D.DEAN/M.TENDLER

A2-01 14 60

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

Sheets and Views
EXTERIOR ELEVATIONS

File details come from the government source that posted it. Updated .