Appendix II - FRP Grout material 5-ft ISO.pdf

PDF 243 KB Posted

Attached to
Air Damage Repair (ADR) Material
Solicitation number
FA805121R3002
Issued by

About this file

This solicitation is for an indefinite delivery/indefinite quantity contract to provide Airfield Damage Repair (ADR) materials to the Air Force Civil Engineer Center. Required items include fiberglass reinforced polymer grout, buckets, pallets, locks and other supplies for securing matting on damaged airfield pavements. The period of performance is a base year with four option years.

Offerors must propose firm fixed prices on the attached price sheet by the deadline of May 17, 2021. Evaluation will be based on technical acceptability, price reasonableness, and past performance. The award will be made to the lowest priced technically acceptable offeror with acceptable past performance who is determined responsible. Small businesses are eligible for total set aside. The estimated value is between $400,000 to $500,000 for the base year. Delivery locations include multiple U.S. and overseas Air Force bases.

View the file

Other files

File Type Posted
ADR Materials price sheet.xlsx XLSX spreadsheet
Questions and Answers 2.docx DOCX document
Questions and Answers 2.docx DOCX document
Questions and Answers 1.docx DOCX document
Combined Synopsis Solicitation FA8051-21-R-3002 ADR Materials QA1.docx DOCX document
Appendix DD - Expedient Spall Repair Material.pdf PDF
Appendix UU - Yellow Airfield Paint 5-gal Bucket.pdf PDF
Appendix CCC - Asphalt Cold Patch 50-lb bucket.pdf PDF
Appendix S - Rapid Set Concrete in 5-gal Bucket.pdf PDF
Appendix GG - FRP Grout Material.pdf PDF
Appendix AA - Pelletized Asphalt 5-gal Bucket.pdf PDF
Appendix H - Wire Basket Top.pdf PDF
Appendix P - Supersack Lined 3-ft x 3-ft x 3-ft.pdf PDF
Appendix NN - Fast Trac 246 20-ft ISO.pdf PDF
Offeror Representations and Certifications attachement FA8051-21-R-3002.docx DOCX document
Appendix EE - Expedient Spall Repair 5-gal Bucket.pdf PDF
Appendix U - Rapid Set Concrete 20-ft ISO.pdf PDF
Appendix LL - Fast Trac 246 Concrete 5-gal Bucket.pdf PDF
Appendix XX - Mineral Spirits 1-gal.pdf PDF
Appendix KK - Fast Trac 246 Training Capping Material.pdf PDF
Appendix I - Wire Basket Bottom.pdf PDF
Appendix E - Inflatable Dunnage Bag.pdf PDF
Appendix G - Supersack Rack.pdf PDF
Appendix YY - Release Agent Concrete 5-gal bucket.pdf PDF
Appendix Z - Pelletized Asphalt Material.pdf PDF
Appendix BB - Pelletized Asphalt Supersack.pdf PDF
Appendix MM - Fast Trac 246 Training Capping Material Supersack.pdf PDF
Appendix OO - Joint Sealant 29-oz Tube.pdf PDF
Appendix W - Flowable Fill 5-gal Bucket.pdf PDF
Appendix SS - Backer Rod.pdf PDF
Appendix VV - White Airfield Paint 5-gal Bucket.pdf PDF
Appendix PP - Expansion Material 4-in x 0.pdf PDF
Appendix FF - Expedient Spall Repair material 5-ft ISO.pdf PDF
Appendix M - Snap Hook Ratchet Strap HD 2-in.pdf PDF
FA8051-21-R-3002 ADR Materials SOW.docx DOCX document
Appendix RR - Plastic Zip Strip 0.5-in x 0.pdf PDF
Appendix C - ISO Container 8-ft x 8-ft x 5-ft FRP Grout Kit.pdf PDF
Appendix Q - Supersack Unlined 2-ft x 2-ft x 2-ft.pdf PDF
Appendix A - ISO Container 8-ft x 8-ft x 20-ft.pdf PDF
Appendix JJ - Citric Acid.pdf PDF
Appendix ZZ - Release Agent Asphalt 5-gal bucket.pdf PDF
Appendix B - ISO Container 8-ft x 8-ft x 5-ft Spall Repair Kit.pdf PDF
Appendix AAA - Curing Compound 5-gal bucket.pdf PDF
FA8051-21-R-3002 ADR Materials price sheet.xlsx XLSX spreadsheet
Appendix R - Rapid Set Concrete Material.pdf PDF
Appendix J - Bucket Riser.pdf PDF
Appendix Y - Flowable Fill 20-ft ISO.pdf PDF
Appendix HH - FRP Grout 5-gal Bucket.pdf PDF
Appendix TT - Black Airfield Paint 5-gal Bucket.pdf PDF
Appendix V - Flowable Fill Material.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix II

FRP Grout Material, 5-ft ISO

1. Introduction. The Air Force Civil Engineer Center (AFCEC) has developed an updated

Airfield Damage Repair (ADR) concept of operations under the ADR Modernization

Program that provides updated capabilities to rapidly repair damaged airfield pavements.

Fiberglass Re-enforced Polymer (FRP) matting system, grout material is used to secure tri-talon anchors in the asphalt airfield pavement structure for the FRP matting system.

2. Scope.

2.1. The contractor shall purchase, modify, prepare, stock, and deliver 5-ft long International

Standards Organization (ISO) cargo containers to selected AF locations in accordance with the detailed technical requirements of this SOW.

2.2. FRP Grout Material, ISO, unit of issue for this IDIQ shall be one (1) kit (KT) to include all of the following items:

2.2.1. One (1) each 5-ft ISO container (Quadcon); the contractor shall verify that all ISO containers meet the specifications and follow all procurement processes in Appendix C.

2.2.2. Four (4) each Wood Pallet, 48-in x 44-in, Heat Treated; the contractor shall verify that all the Wood Pallet, 48-in x 44-in, Heat Treated meets the specifications in Appendix L.

The contractor shall load all the FRP Grout material, 5-gal buckets on to the four (4)

Wood Pallets based on the packing diagram in paragraph 3.

2.2.2.1.The contractor shall secure forty-two (42) each of FRP Grout Material buckets (14 buckets per row and placed three (3) rows of bucket on each wood pallet (bottom). The contractor shall secure the forty-two (42) of FRP Grout Material buckets on the two (2) wood pallets using 1/2-in x.020-in metal strapping, 1/2-in metal banding seals, Cast 80

GA Stretch Wrap, and 200-lb test corrugates fanfold as depicted packing diagram in paragraph 3.

2.2.2.2.The contractor shall secure twenty-eight (28) each of FRP Grout Material buckets (14 buckets per row and placed two (2) rows of bucket on each wood pallet (top). The contractor shall secure the twenty-eight (28) of FRP Grout Material buckets on the two

(2) wood pallets using 1/2-in x.020-in metal strapping, 1/2-in metal banding seals, Cast

80 GA Stretch Wrap, and 200-lb test corrugates fanfold as depicted packing diagram in paragraph 3.

2.2.3. Two (2) each Snap Hook ratchet Strap, Heavy Duty, 2-in; the contractor shall verify that all the Snap Hook ratchet Strap, Heavy Duty, 2-in meets the specifications in

Appendix M. The contractor shall secure the FRP Grout material 5-gal buckets loaded onto the Wood Pallets in the QuadCon based on packing diagram in paragraph 3.

2.2.4. Four (4) each Bucket Lid Opener; the contractor shall verify that all the Bucket Lid

Opener meets the specifications in Appendix N. The contractor shall secure one Bucket

Lid Opener to a bucket on each wood pallet (facing the doors) as depicted in the packing diagram in paragraph 3.

2.2.5. One-hundred forty (140) each 5-gal buckets of FRP Grout material; the contractor shall verify that all the FRP Grout material meets the specifications in Appendix GG. The contractor shall place and secure the FRP Grout material 5-gal buckets on the Wood

Pallets based on packing diagram in paragraph 3.

2.2.6. Two (2) each locks, combination; after completion of packing, the contractor shall lock the cargo doors using two locks that meets the specification in Appendix O. The combination to be used will be provided per task order.

2.3. The contractor shall provide all loading and unloading capability for fully packed and sealed ISO containers with 11,200-lbs maximum gross weight to include place of origin, shipping dock, and final destination. The contractor shall weigh fully loaded ISO containers and provide weigh scale documentation to transport driver. The contractor shall provide door to door delivery without assistance.

2.4. The contractor shall provide monthly updates to the 772 ESS/PKD and AFCEC/CXXM, with the first report due not later than 30 calendar days after task order award and every 30 days thereafter until task order completion. Each task order monthly update shall include at minimum an updated overall project schedule and status of all containers.

3. Packing Layout.

FRP Grout material 5-gal bucket packing on pallets packing, diagram.

FRP Grout material packing/strapping, diagram.