This is a notice for a forthcoming request for proposal for a human space flight technical integration contract. NASA/JSC plans to issue the RFP on or about November 1, 2019, with an anticipated offer due date of December 11, 2019. The procurement is a total small business set-aside with a NAICS code of 541715 and size standard of 1,250. The contract will provide technical integration services for human space flight. Offerors should monitor the listed websites for the RFP release and any amendments. All technical questions must be submitted in writing.
SSP 42001-RevW
View the file
Other files for this federal contract opportunity
Show all 50
Human Space Flight Technical Integration Contract (HSFTIC) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
United States On-orbit Segment to Columbus Attached Pressurized Module Interface Control Document
International Space Station Program
Revision W
November 2015
EAR 99. This document contains data within the purview of the U.S. Export Administration Regulations (EAR), 15 CFR 730-774, and is export controlled. The document may be used only in the International Space Station (ISS) program to fulfill responsibilities of the Parties or of a Cooperating Agency of an ISS Partner in furtherance of the ISS Intergovernmental Agreement. Re-transfer or disclosure to, or use by, any persons other than citizens of ISS Program International Partner countries, or use for any other purpose, requires prior U.S. Government authorization.
National Aeronautics and Space Administration International Space Station Program Johnson Space Center Houston, Texas Contract No.: NNJ12GA46C
SSP 42001
REVISION AND HISTORY
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
REVISION AND HISTORY – Continued
| REV. |
| DESCRIPTION |
| PUB. DATE |
| W |
| Revision W (Reference per SSCD 15295, EFF. 12-02-15) |
| 03-08-16 |
Revision W incorporates the following PIRNs/IRNs with the associated SSCNs:
PIRN IRN SSCN
42001-ES-0447 N/A 015295
42001-ES-0448 N/A 015295
42001-ES-0449 N/A 015295
42001-NA-0252 N/A 015295
42001-NA-0253 N/A 015295
42001-NA-0254 N/A 015295
42001-NA-0255 N/A 015295
42001-NA-0256 0083 012906
0084 013058 0085 013437 0086 013573 0087 013845
Revision W
PREFACE
united states on-orbit segment To Columbus Attached Pressurized Module Interface Control Document The United States On-orbit Segment (USOS) to Columbus Attached Pressurized Module (APM) Interface Control Document (ICD) establishes the design of the interface(s) between the USOS and the Columbus APM.
This document defines the implementation of both the USOS and the Columbus APM regarding physical, functional, and environmental interfaces.
The contents of this document are intended to be consistent with the tasks and products to be prepared by the International Space Station (ISS) Program Partners as defined in SSP 41000, ISS System Specification. This Interface Control Document shall be implemented on all new ISS Program activities and shall be included in any existing contracts through contract changes. This document is under the control of the Interface Control Working Group (ICWG), as described in SSP 30459, ISS Interface Control Plan.
INTERNATIONAL SPACE STATION PROGRAM
united states on-orbit segment To Columbus Attached Pressurized Module Interface Control Document
CONCURRENCE
november 2015 xxvii
TABLE OF CONTENTS
| PARAGRAPH | PAGE | ||
| 1.0 | INTRODUCTION | 1-1 | |
| 1.1 | PURPOSE and scope | 1-1 | |
| 1.2 | precedence | 1-1 | |
| 1.3 | delegation of authority | 1-1 | |
| 2.0 | DOCUMENTS | 2-1 | |
| 2.1 | applicable documents | 2-1 | |
| 2.2 | reference documents | 2-6 | |
| 3.0 | INTERFACE | 3-1 | |
| 3.1 | GENERAL | 3-1 | |
| 3.1.1 | Interface Description | 3-1 | |
| 3.1.2 | Interface Responsibilities | 3-3 | |
| 3.1.3 | Coordinate Systems | 3-3 | |
| 3.1.4 | Envelope Interfaces | 3-6 | |
| 3.1.4.1 | External Configuration Envelopes | 3-6 | |
| 3.1.4.1.1 | Module Envelope Without External Payloads | 3-6 | |
| 3.1.4.1.1.1 | EXTERNAL PAYLOAD FIELD OF VIEW | 3-8 | |
| 3.1.4.1.2 | EXTERNAL CONFIGURATION PHYSICAL ENVELOPE | 3-8 | |
| 3.1.4.1.3 | SPDM INTERFACES | 3-8 | |
| 3.1.4.1.4 | RADIO FREQUENCY ANTENNAS | 3-8 | |
| 3.1.4.1.4.1 | COLUMBUS AMATEUR RADIO ANTENNA | 3-8 | |
| 3.1.4.1.4.1.1 | GENERAL | 3-8 | |
| 3.1.4.1.4.1.2 | ANTENNA LOCATION AND ENVELOPE | 3-16 | |
| 3.1.4.1.4.2 | VERY HIGH FREQUENCY ANTENNAS | 3-16 | |
| 3.1.4.1.4.2.1 | MARITIME AUTOMATED IDENTIFICATION SYSTEM ANTENNA | 3-16 | |
| 3.1.4.1.4.2.2 | ISS AMATEUR RADIO ANTENNA | 3-16 | |
| 3.1.4.1.4.2.3 | ANTENNA LOCATIONS AND ENVELOPES | 3-16 | |
| 3.1.4.1.4.2.4 | ANTENNA CABLE ROUTING | 3-16 | |
| 3.1.4.1.4.3 | ANTENNA CHARACTERISTICS (FOR REFERENCE ONLY) | 3-23 | |
| 3.1.4.1.5 | EXTERNAL PARKING PAYLOAD AND TERMINAL INTERFACES | 3-23 | |
| 3.1.4.1.5.1 | MODULE TRUNNIONS WITH EUTAS INTERFACE | 3-23 | |
| 3.1.4.1.5.2 | MODULE EVA CONNECTORS | 3-23 | |
| 3.1.4.2 | INTERNAL CONFIGURATION ENVELOPES | 3-23 | |
| 3.1.4.2.1 | APM HATCH AND UTILITIES ACCOMMODATION ENVELOPE | 3-23 | |
| 3.1.5 | MASS PROPERTIES | 3-27 | |
| 3.1.5.1 | COLUMBUS ATTACHED PRESSURIZED MODULE | 3-27 | |
| 3.1.5.2 | COMMON BERTHING MECHANISM RIGID PASSIVE HALF | 3-27 | |
| 3.1.5.3 | HATCH | 3-27 | |
| 3.1.5.4 | EVA SYSTEM | 3-27 | |
| 3.1.5.5 | MAN SYSTEMS | 3-27 | |
| 3.1.6 | ACCOMMODATION OF THE CENTERLINE BERTHING CAMERA SYSTEM TARGETS | 3-28 | |
| 3.2 | STRUCTURAL INTERFACES | 3-28 | |
| 3.2.1 | SPACE STATION MANNED BASE/ATTACHED PRESSURIZED MODULE | ||
| STRUCTURAL ATTACHMENT | 3-28 | ||
| 3.2.1.1 | INTERFACE WITH THE PASSIVE CBM | 3-28 | |
| 3.2.1.2 | APM STRUCTURAL MATHEMATICAL MODEL | 3-28 | |
| 3.2.2 | HATCH TO APM STRUCTURAL INTERFACES | 3-28 | |
| 3.2.3 | MAN SYSTEMS AND PORTABLE EQUIPMENT | 3-28 | |
| 3.2.3.1 | SEAT TRACK LOCAL LOAD CARRYING CAPABILITY | 3-28 | |
| 3.2.4 | EVA SYSTEM | 3-29 | |
| 3.3 | MECHANICAL INTERFACES | 3-31 | |
| 3.3.1 | SPACE STATION MANNED BASE ATTACHED PRESSURIZED MODULE MECHANICAL ATTACHMENT | 3-31 | |
| 3.3.2 | HATCH TO APM MECHANICAL INTERFACE | 3-31 | |
| 3.3.3 | ATTACHED PRESSURIZED MODULE FORWARD BULKHEAD MOUNTED CONNECTORS | 3-31 | |
| 3.3.3.1 | INTERFACE LOCATION | 3-31 | |
| 3.3.3.2 | APM BULKHEAD UTILITY CONNECTOR TYPES | 3-31 | |
| 3.3.4 | EVA SYSTEM | 3-37 | |
| 3.3.5 | MAN SYSTEMS | 3-37 | |
| 3.3.5.1 | INTERELEMENT CLOSE−OUT PANELS ATTACHMENT HARDWARE | 3-37 | |
| 3.3.5.2 | PORTABLE FIRE EXTINGUISHER | 3-37 | |
| 3.3.5.3 | PORTABLE BREATHING APPARATUS | 3-37 | |
| 3.3.5.4 | PORTABLE EQUIPMENT INTERFACES | 3-37 | |
| 3.3.6 | STANDARD UTILITY PANEL | 3-39 | |
| 3.3.6.1 | APM−STANDARD UTILITY PANEL | 3-39 | |
| 3.3.6.2 | NODE 2 UTILITY OUTLET PANEL FOR THE APM PORTABLE WORKSTATION/ JOINT STATION LAN EDGE ROUTER | 3-41 | |
| 3.3.6.3 | PORTABLE WORKSTATION HARNESS CONFIGURATION | 3-42 | |
| 3.3.6.3.1 | US PORTABLE WORKSTATION HARNESS CONFIGURATION | 3-42 | |
| 3.3.6.3.2 | APM PORTABLE WORKSTATION HARNESS CONFIGURATION | 3-43 | |
| 3.3.6.3.3 | US STATION SUPPORT COMPUTER HARNESS CONFIGURATION | 3-44 | |
| 3.3.6.4 | JSL ER HARNESS | 3-45 | |
| 3.3.6.4.1 | US JSL ER HARNESS CONFIGURATION | 3-45 | |
| 3.4 | ENVIRONMENTAL INTERFACES | 3-46 | |
| 3.5 | SYSTEM INTERFACES | 3-46 | |
| 3.5.1 | ELECTRICAL POWER SYSTEM | 3-46 | |
| 3.5.1.1 | INTERFACE DESCRIPTION | 3-49 | |
| 3.5.1.1.1 | POWER SOURCE CHARACTERISTICS | 3-49 | |
| 3.5.1.1.1.1 | NOMINAL POWER PERFORMANCE / POWER AVAILABILITY | 3-49 | |
| 3.5.1.1.1.1.1 | SOURCE IMPEDANCE | 3-49 | |
| 3.5.1.1.1.1.2 | INTEGRATED LOAD IMPEDANCE | 3-50 | |
| 3.5.1.1.1.1.2.1 | DELETED | 3-50 | |
| 3.5.1.1.1.1.2.2 | DELETED | 3-50 | |
| 3.5.1.1.1.2 | ABNORMAL POWER CHARACTERISTICS | 3-55 | |
| 3.5.1.1.1.2.1 | OUTPUT OVERVOLTAGE SHUTDOWN | 3-55 | |
| 3.5.1.1.1.2.2 | OUTPUT PROTECTION | 3-56 | |
| 3.5.1.1.1.2.2.1 | CURRENT LIMITING | 3-56 | |
| 3.5.1.1.1.2.2.2 | OVERCURRENT TRIPPING | 3-56 | |
| 3.5.1.1.1.2.2.3 | DELETED | 3-57 | |
| 3.5.1.1.1.2.2.4 | RESIDUAL CURRENT IN POWER−OFF MODE | 3-57 | |
| 3.5.1.1.1.3 | POWER SHARING BETWEEN POWER FEEDERS | 3-57 | |
| 3.5.1.1.1.4 | ISS−GENERATED VOLTAGE RIPPLE | 3-57 | |
| 3.5.1.1.2 | APM LOAD CHARACTERISTICS | 3-58 | |
| 3.5.1.1.2.1 | APM OVERCURRENT PROTECTION | 3-58 | |
| 3.5.1.1.2.1.1 | SSPC CONTROL | 3-58 | |
| 3.5.1.1.2.1.2 | CONTROL OF DC−TO−DC CONVERTERS | 3-59 | |
| 3.5.1.1.2.2 | APM GENERATED VOLTAGE RIPPLE | 3-59 | |
| 3.5.1.2 | BONDING | 3-59 | |
| 3.5.1.3 | HARNESS | 3-59 | |
| 3.5.1.4 | POWER RETURN GROUNDING / ISOLATION | 3-61 | |
| 3.5.1.5 | RESERVE | 3-61 | |
| 3.5.1.6 | POWER OUTLETS OF APM STANDARD UTILITY PANELS | 3-61 | |
| 3.5.1.6.1 | CONCEPTUAL LAYOUT | 3-61 | |
| 3.5.1.6.2 | POWER SPECIFICATIONS | 3-61 | |
| 3.5.1.6.3 | POWER LOAD INTERFERENCE | 3-65 | |
| 3.5.1.6.4 | GROUNDING AND ISOLATION | 3-68 | |
| 3.5.1.6.5 | BONDING | 3-68 | |
| 3.5.1.6.6 | POWER CONNECTOR DEFINITION | 3-68 | |
| 3.5.1.6.7 | POWER CONTROL | 3-68 | |
| 3.5.1.7 | POWER TO US PCS−WS AND APM PORTABLE WORKSTATION | 3-68 | |
| 3.5.1.7.1 | POWER TO US PCS−WS | 3-68 | |
| 3.5.1.7.2 | POWER TO APM PORTABLE WORKSTATION | 3-68 | |
| 3.5.2 | AVIONICS SYSTEM | 3-68 | |
| 3.5.2.1 | AVIONICS SYSTEM FUNCTIONAL INTERFACES | 3-68 | |
| 3.5.2.1.1 | AVIONICS SYSTEM FUNCTIONAL INTERFACE IDENTIFICATION | 3-69 | |
| 3.5.2.1.2 | COMMAND & CONTROL INTERFACES | 3-69 | |
| 3.5.2.1.2.1 | ACTIVATION/DEACTIVATION | 3-69 | |
| 3.5.2.1.2.2 | OVERALL STATION MANAGEMENT | 3-71 | |
| 3.5.2.1.2.3 | SSMB SUPPORT FOR APM OPERATIONS | 3-71 | |
| 3.5.2.1.2.3.1 | LOSS OF THERMAL CAPABILITY | 3-71 | |
| 3.5.2.1.2.4 | TROUBLE SHOOTING | 3-72 | |
| 3.5.2.1.2.5 | RECONFIGURATION REQUESTS | 3-72 | |
| 3.5.2.1.2.6 | DELETED | 3-72 | |
| 3.5.2.1.2.7 | ANCILLARY DATA | 3-72 | |
| 3.5.2.1.2.8 | P/L COMMAND AND CONTROL | 3-72 | |
| 3.5.2.1.2.9 | COMMAND WINDOWS/DISPLAYS | 3-72 | |
| 3.5.2.1.3 | EMERGENCY, WARNING, CAUTION AND SAFING | 3-72 | |
| 3.5.2.1.3.1 | GENERAL | 3-72 | |
| 3.5.2.1.3.2 | VTC LINK | 3-73 | |
| 3.5.2.1.3.3 | NOMINAL DMS LINK | 3-74 | |
| 3.5.2.1.4 | COMMUNICATION | 3-77 | |
| 3.5.2.1.4.1 | DATA ROUTING | 3-77 | |
| 3.5.2.1.4.2 | AUDIO | 3-77 | |
| 3.5.2.1.4.3 | VIDEO | 3-78 | |
| 3.5.2.2 | DATA MANAGEMENT SYSTEM GENERAL DESCRIPTION | 3-78 | |
| 3.5.2.3 | SSMB COMMAND AND CONTROL BUSES INTERFACE | 3-81 | |
| 3.5.2.3.1 | FUNCTIONAL DESCRIPTION | 3-81 | |
| 3.5.2.3.2 | NETWORK CHARACTERISTICS | 3-81 | |
| 3.5.2.3.2.1 | WIRING | 3-81 | |
| 3.5.2.3.2.2 | BUS COUPLER AND BUS TERMINATION | 3-81 | |
| 3.5.2.3.2.3 | SIGNAL CHARACTERISTICS | 3-82 | |
| 3.5.2.3.3 | HOOK−UP POINTS FOR US PCS−WS CONNECTED TO THE C&C BUSES | 3-83 | |
| 3.5.2.3.3.1 | CABLE CHARACTERISTICS OF US PCS−WS HOOK−UP POINTS | 3-83 | |
| 3.5.2.3.4 | PROTOCOL CHARACTERISTICS ON THE C&C BUSES | 3-83 | |
| 3.5.2.3.5 | APM REMOTE TERMINAL ADDRESSES ON THE C&C BUSES | 3-84 | |
| 3.5.2.4 | HARDWIRED INTERFACES | 3-84 | |
| 3.5.2.4.1 | FUNCTIONAL DESCRIPTION | 3-84 | |
| 3.5.2.4.1.1 | VTC AND PDU INTERFACE DATA DEFINITIONS | 3-85 | |
| 3.5.2.4.2 | PERFORMANCE, HARNESS AND SIGNAL CHARACTERISTICS | 3-88 | |
| 3.5.2.4.2.1 | 15 VOLT COMMANDS | 3-88 | |
| 3.5.2.4.2.2 | STATUS INTERFACES | 3-93 | |
| 3.5.2.4.2.3 | ANALOG INTERFACES | 3-93 | |
| 3.5.2.4.2.4 | DELETED | 3-93 | |
| 3.5.2.5 | MIL−STD−1553B LAYER 2 PROTOCOL DESCRIPTION | 3-99 | |
| 3.5.2.5.1 | GENERAL | 3-99 | |
| 3.5.2.5.2 | WORD INTERFACE | 3-99 | |
| 3.5.2.5.2.1 | COMMAND WORD INTERFACE | 3-99 | |
| 3.5.2.5.2.1.1 | SYNC | 3-101 | |
| 3.5.2.5.2.1.2 | REMOTE TERMINAL ADDRESS | 3-101 | |
| 3.5.2.5.2.1.3 | TRANSMIT/RECEIVE BIT | 3-101 | |
| 3.5.2.5.2.1.4 | SUBADDRESS/MODE (SAM) FIELD | 3-101 | |
| 3.5.2.5.2.1.5 | DATA WORD COUNT/MODE CODE | 3-103 | |
| 3.5.2.5.2.1.5.1 | SYNCHRONIZE (W/O DATA WORDS) | 3-104 | |
| 3.5.2.5.2.1.5.2 | TRANSMIT STATUS WORD | 3-104 | |
| 3.5.2.5.2.1.5.3 | INITIATE SELF TEST | 3-104 | |
| 3.5.2.5.2.1.5.4 | TRANSMITTER SHUTDOWN (SD) | 3-104 | |
| 3.5.2.5.2.1.5.5 | OVERRIDE TRANSMITTER SD | 3-104 | |
| 3.5.2.5.2.1.5.6 | INHIBIT TERMINAL FLAG | 3-104 | |
| 3.5.2.5.2.1.5.7 | OVERRIDE INHIBIT TERMINAL FLAG | 3-104 | |
| 3.5.2.5.2.1.5.8 | RESET REMOTE TERMINAL | 3-104 | |
| 3.5.2.5.2.1.5.9 | TRANSMIT VECTOR WORD | 3-105 | |
| 3.5.2.5.2.1.5.10 | SYNCHRONIZE (WITH DATA WORDS) | 3-105 | |
| 3.5.2.5.2.1.5.11 | TRANSMIT LAST COMMAND | 3-105 | |
| 3.5.2.5.2.1.5.12 | TRANSMIT BIT WORD | 3-105 | |
| 3.5.2.5.2.1.6 | PARITY | 3-105 | |
| 3.5.2.5.2.2 | STATUS WORD INTERFACE | 3-105 | |
| 3.5.2.5.2.2.1 | SYNC | 3-106 | |
| 3.5.2.5.2.2.2 | REMOTE TERMINAL ADDRESS | 3-106 | |
| 3.5.2.5.2.2.3 | MESSAGE ERROR BIT | 3-106 | |
| 3.5.2.5.2.2.4 | INSTRUMENTATION BIT | 3-106 | |
| 3.5.2.5.2.2.5 | SERVICE REQUEST BIT | 3-106 | |
| 3.5.2.5.2.2.6 | RESERVED | 3-107 | |
| 3.5.2.5.2.2.7 | BROADCAST COMMAND RECEIVED BIT | 3-107 | |
| 3.5.2.5.2.2.8 | BUSY BIT | 3-107 | |
| 3.5.2.5.2.2.9 | SUBSYSTEM FLAG BIT | 3-107 | |
| 3.5.2.5.2.2.10 | DYNAMIC BUS CONTROL ACCEPTANCE BIT | 3-107 | |
| 3.5.2.5.2.2.11 | TERMINAL FLAG BIT | 3-107 | |
| 3.5.2.5.2.2.12 | PARITY | 3-107 | |
| 3.5.2.5.2.2.13 | NO STATUS WORD RETURNED | 3-107 | |
| 3.5.2.5.2.2.14 | STATUS WORD RESET | 3-107 | |
| 3.5.2.5.2.3 | DATA WORD INTERFACE | 3-108 | |
| 3.5.2.5.2.3.1 | SYNC | 3-108 | |
| 3.5.2.5.2.3.2 | DATA | 3-108 | |
| 3.5.2.5.2.3.3 | PARITY | 3-108 | |
| 3.5.2.5.3 | STANDARD MESSAGES | 3-108 | |
| 3.5.2.5.3.1 | RECEIVE DATA MESSAGE (BC TO RT) | 3-108 | |
| 3.5.2.5.3.1.1 | FUNCTION | 3-109 | |
| 3.5.2.5.3.1.2 | MESSAGE FORMAT | 3-109 | |
| 3.5.2.5.3.2 | TRANSMIT DATA MESSAGE (RT TO BC) | 3-109 | |
| 3.5.2.5.3.2.1 | FUNCTION | 3-110 | |
| 3.5.2.5.3.2.2 | MESSAGE FORMAT | 3-110 | |
| 3.5.2.5.4 | BROADCAST DATA MESSAGES | 3-110 | |
| 3.5.2.5.4.1 | TIME DISTRIBUTION | 3-111 | |
| 3.5.2.5.4.2 | SYNCHRONIZATION | 3-111 | |
| 3.5.2.5.4.3 | ANCILLARY DATA | 3-111 | |
| 3.5.2.5.5 | SYNCHRONOUS PACKET DATA TRANSFER (SPT) | 3-111 | |
| 3.5.2.5.6 | C&DH ERROR HANDLING | 3-118 | |
| 3.5.2.5.6.1 | 1553B CHANNEL MANAGEMENT | 3-118 | |
| 3.5.2.5.6.2 | APM REMOTE TERMINAL FDIR | 3-119 | |
| 3.5.2.5.6.2.1 | VTC1 / VTC2 STATUS INDICATIONS | 3-120 | |
| 3.5.2.5.6.2.2 | MMC STATUS INDICATIONS | 3-120 | |
| 3.5.2.5.6.2.3 | SSMB MONITORING FOR APM RTs | 3-120 | |
| 3.5.2.5.6.3 | SSMB BUS CONTROLLER FDIR | 3-120 | |
| 3.5.2.5.6.3.1 | TIME TO RECOVERY OF SSMB BC OPERATIONS | 3-121 | |
| 3.5.2.5.6.3.2 | PROCESSING FRAME SYNCHRONIZATION FOLLOWING RECOVERY | 3-121 | |
| 3.5.2.6 | DOWNLINK DATA INTERFACES | 3-121 | |
| 3.5.2.6.1 | FUNCTIONAL DESCRIPTION | 3-123 | |
| 3.5.2.6.1.1 | DOWNLINK DATA APPLICATION PROCESS IDENTIFIER (APID) | 3-123 | |
| 3.5.2.6.2 | PERFORMANCE CHARACTERISTICS | 3-124 | |
| 3.5.2.6.3 | DATA RATES | 3-124 | |
| 3.5.2.6.4 | OPTICAL CHARACTERISTICS | 3-124 | |
| 3.5.2.6.4.1 | TRANSMITTER OPTICAL CABLE CHARACTERISTICS | 3-125 | |
| 3.5.2.6.4.2 | APM OPTICAL OUTPUT CHARACTERISTICS | 3-126 | |
| 3.5.2.6.5 | PROTOCOL ON HIGH RATE DATA LINKS | 3-127 | |
| 3.5.2.6.5.1 | ENCODING | 3-127 | |
| 3.5.2.6.5.1.1 | CONTROL SYMBOLS | 3-127 | |
| 3.5.2.6.5.1.2 | SYNC SYMBOL | 3-127 | |
| 3.5.2.6.5.1.3 | START DELIMITER SYMBOLS | 3-127 | |
| 3.5.2.6.5.1.4 | END DELIMITER SYMBOLS | 3-127 | |
| 3.5.2.6.5.1.5 | INVALID SYMBOLS | 3-127 | |
| 3.5.2.6.5.2 | STATION PROTOCOL RULES | 3-127 | |
| 3.5.2.6.5.2.1 | PROTOCOL STATES | 3-128 | |
| 3.5.2.6.5.2.2 | INITIALIZATION STATE | 3-129 | |
| 3.5.2.6.5.2.3 | LOCK−ON STATE | 3-129 | |
| 3.5.2.6.5.2.4 | DATA_SEND STATE | 3-130 | |
| 3.5.2.6.5.2.5 | RECONFIGURE STATE | 3-130 | |
| 3.5.2.6.5.2.6 | BITSTREAM PROTOCOL | 3-130 | |
| 3.5.2.6.5.2.6.1 | BITSTREAM DATA FRAMES | 3-131 | |
| 3.5.2.6.5.2.6.1.1 | BITSTREAM INTER−FRAME GAPS | 3-131 | |
| 3.5.2.6.5.2.6.2 | BITSTREAM DATA RATES | 3-131 | |
| 3.5.2.6.5.2.6.2.1 | MINIMUM REQUIRED SYNC SYMBOLS | 3-131 | |
| 3.5.2.6.5.2.6.2.2 | DISTRIBUTION OF SYNC SYMBOLS | 3-132 | |
| 3.5.2.6.5.2.6.2.3 | MAXIMUM CONTIGUOUS DATA BYTES | 3-132 | |
| 3.5.2.6.5.2.6.3 | DELETED | 3-133 | |
| 3.5.2.7 | PAYLOAD BUSES AND EXTENSION FOR APM PORTABLE WORKSTATIONS | 3-133 | |
| 3.5.2.7.1 | LAN ACCESSIBILITY FOR APM PORTABLE WORKSTATION IN SSMB | 3-133 | |
| 3.5.2.7.1.1 | LAN CABLE CHARACTERISTICS | 3-134 | |
| 3.5.2.7.1.2 | LAN INTERFACE DIAGRAM | 3-134 | |
| 3.5.2.7.2 | US PAYLOAD BUS EXTENSION TO APM | 3-135 | |
| 3.5.2.7.2.1 | HOOK−UP POINTS FOR US PCS−WS CONNECTED TO THE US PAYLOAD BUS | 3-138 | |
| 3.5.2.7.2.2 | NETWORK CHARACTERISTICS | 3-138 | |
| 3.5.2.7.2.3 | DELETED | 3-138 | |
| 3.5.2.7.2.4 | BUS COUPLER AND BUS TERMINATION | 3-139 | |
| 3.5.2.7.2.5 | SIGNAL CHARACTERISTICS | 3-139 | |
| 3.5.2.7.2.6 | PEHG RT ADDRESS | 3-139 | |
| 3.5.2.8 | SSMB TO APM HIGH RATE DATA LINK (HRDL) | 3-139 | |
| 3.5.2.8.1 | GENERAL | 3-139 | |
| 3.5.2.8.2 | optical characteristics | 3-139 | |
| 3.5.3 | THERMAL CONTROL SYSTEM | 3-140 | |
| 3.5.3.1 | THERMAL CONTROL SYSTEM INTERFACES | 3-140 | |
| 3.5.3.2 | ACTIVE THERMAL CONTROL SYSTEM | 3-144 | |
| 3.5.3.2.1 | INTERFACE PERFORMANCE CHARACTERISTICS | 3-144 | |
| 3.5.3.2.1.1 | NOMINAL CASE | 3-144 | |
| 3.5.3.2.1.2 | OFF−NOMINAL CASES | 3-144 | |
| 3.5.3.3 | INTERFACE DESCRIPTION | 3-147 | |
| 3.5.3.3.1 | SSMB THERMAL BUSSES PRESSURE DROP | 3-147 | |
| 3.5.3.3.2 | PHYSICAL DESCRIPTION | 3-147 | |
| 3.5.3.4 | PASSIVE THERMAL CONTROL SYSTEM | 3-150 | |
| 3.5.3.4.1 | LOCAL INTERFACES | 3-150 | |
| 3.5.3.4.2 | DELETED | 3-153 | |
| 3.5.3.4.3 | THERMAL DESIGN CONFIGURATION MODELS | 3-153 | |
| 3.5.3.4.3.1 | THERMAL DESIGN CONFIGURATION MODEL OF SPACE STATION MANNED BASE | 3-153 | |
| 3.5.3.4.3.2 | THERMAL DESIGN CONFIGURATION MODEL OF ATTACHED PRESSURIZED MODULE | 3-153 | |
| 3.5.4 | COMMUNICATIONS AND TRACKING SYSTEM | 3-153 | |
| 3.5.4.1 | COMMUNICATIONS AND TRACKING SYSTEM PHYSICAL INTERFACES − GENERAL DESCRIPTION | 3-153 | |
| 3.5.4.2 | AUDIO | 3-154 | |
| 3.5.4.2.1 | HARDWIRED AUDIO | 3-154 | |
| 3.5.4.2.1.1 | HARDWIRED AUDIO INTERFACE CHARACTERISTICS | 3-156 | |
| 3.5.4.2.2 | INTRAVEHICULAR ANTENNA ASSEMBLY (IAA) | 3-156 | |
| 3.5.4.2.2.1 | IAA ACCOMMODATION IN APM | 3-157 | |
| 3.5.4.2.2.1.1 | ANTENNA LOCATION IN APM | 3-157 | |
| 3.5.4.2.2.2 | UHF CHARACTERISTICS | 3-157 | |
| 3.5.4.3 | VIDEO | 3-159 | |
| 3.5.4.3.1 | PHYSICAL VIDEO INTERFACE CHARACTERISTICS | 3-164 | |
| 3.5.4.3.2 | VIDEO CAMERA ADDRESSES | 3-166 | |
| 3.5.5 | GUIDANCE, NAVIGATION, AND CONTROL SYSTEM | 3-167 | |
| 3.5.6 | EXTRAVEHICULAR ACTIVITY SYSTEM | 3-167 | |
| 3.5.6.1 | EVA AIDS INTERFACE LAYOUT ON APM | 3-167 | |
| 3.5.6.2 | EVA WORKSITE INTERFACE | 3-177 | |
| 3.5.6.2.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-177 | |
| 3.5.6.2.2 | EVA ENVELOPE | 3-179 | |
| 3.5.6.3 | EVA STANDARD TOOLS | 3-179 | |
| 3.5.6.3.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-179 | |
| 3.5.6.4 | “T” HANDLE RECEPTACLE (HEX) INTERFACE | 3-179 | |
| 3.5.6.5 | EVA HANDRAILS | 3-179 | |
| 3.5.6.5.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-179 | |
| 3.5.6.5.2 | EVA ENVELOPE | 3-181 | |
| 3.5.6.5.3 | GROUND INSTALLED HANDRAILS | 3-181 | |
| 3.5.6.5.4 | ON ORBIT INSTALLED HANDRAILS | 3-181 | |
| 3.5.6.6 | EVA SLIDEWIRE | 3-181 | |
| 3.5.6.7 | EVA MICROCONICAL | 3-181 | |
| 3.5.6.7.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-181 | |
| 3.5.6.7.2 | EVA ENVELOPE | 3-181 | |
| 3.5.7 | ENVIRONMENTAL CONTROL AND LIFE SUPPORT SYSTEM | 3-185 | |
| 3.5.7.1 | TEMPERATURE AND HUMIDITY CONTROL (INTERMODULE VENTILATION) | 3-188 | |
| 3.5.7.1.1 | INTERMODULE VENTILATION AIR SUPPLY TO ATTACHED PRESSURIZED MODULE | 3-188 | |
| 3.5.7.1.1.1 | INTERFACE PERFORMANCE CHARACTERISTICS | 3-188 | |
| 3.5.7.1.1.2 | INTERFACE DESCRIPTION | 3-188 | |
| 3.5.7.1.2 | INTERMODULE VENTILATION AIR RETURN TO SPACE STATION MANNED BASE | 3-193 | |
| 3.5.7.1.2.1 | INTERFACE PERFORMANCE CHARACTERISTICS | 3-193 | |
| 3.5.7.1.2.2 | INTERFACE DESCRIPTION | 3-193 | |
| 3.5.7.2 | ATMOSPHERE CONTROL AND SUPPLY (ATTACHED PRESSURIZED MODULE REPRESSURIZATION) | 3-193 | |
| 3.5.7.2.1 | DELETED | 3-194 | |
| 3.5.7.2.2 | NITROGEN | 3-194 | |
| 3.5.7.2.2.1 | NITROGEN PURITY | 3-194 | |
| 3.5.7.2.2.2 | INTERFACE DESCRIPTION | 3-194 | |
| 3.5.7.3 | ATMOSPHERE REVITALIZATION (AIR SAMPLING) | 3-194 | |
| 3.5.7.3.1 | INTERFACE PERFORMANCE CHARACTERISTICS | 3-194 | |
| 3.5.7.3.2 | INTERFACE DESCRIPTION | 3-194 | |
| 3.5.7.4 | WATER RECOVERY MANAGEMENT (CONDENSATE WATER RETURN) | 3-194 | |
| 3.5.7.4.1 | INTERFACE DESCRIPTION | 3-195 | |
| 3.5.7.5 | ECLSS INTERFACE CONNECTORS DATA | 3-195 | |
| 3.5.7.6 | LOCAL FIRE SUPPRESSION | 3-195 | |
| 3.5.7.6.1 | PHYSICAL INTERFACE | 3-195 | |
| 3.5.7.6.2 | INTERFACE CHARACTERISTICS | 3-195 | |
| 3.5.8 | MAN SYSTEMS | 3-196 | |
| 3.5.8.1 | INTERELEMENT CLOSE−OUT PANELS | 3-196 | |
| 3.5.8.1.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-196 | |
| 3.5.8.1.2 | FUNCTIONAL ENVELOPE | 3-196 | |
| 3.5.8.2 | PORTABLE FIRE EXTINGUISHER | 3-196 | |
| 3.5.8.2.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-199 | |
| 3.5.8.2.2 | HARDWARE ENVELOPE | 3-199 | |
| 3.5.8.2.3 | PFE MECHANICAL INTERFACES | 3-199 | |
| 3.5.8.3 | PORTABLE BREATHING APPARATUS | 3-199 | |
| 3.5.8.3.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-199 | |
| 3.5.8.3.2 | HARDWARE ENVELOPE | 3-199 | |
| 3.5.8.3.3 | PBA MECHANICAL INTERFACES | 3-199 | |
| 3.5.8.4 | TRASH RECEPTACLE | 3-199 | |
| 3.5.8.4.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-199 | |
| 3.5.8.4.2 | FUNCTIONAL ENVELOPE | 3-200 | |
| 3.5.8.5 | ISS VACUUM CLEANER | 3-200 | |
| 3.5.8.5.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-200 | |
| 3.5.8.5.2 | FUNCTIONAL ENVELOPE | 3-200 | |
| 3.5.8.6 | ISS IVA PORTABLE LIGHTS | 3-200 | |
| 3.5.8.6.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-200 | |
| 3.5.8.6.2 | FUNCTIONAL ENVELOPE | 3-200 | |
| 3.5.8.7 | DELETED | 3-200 | |
| 3.5.8.8 | ISS IVA SPECIAL TOOLS | 3-200 | |
| 3.5.8.8.1 | INTERFACE FUNCTIONAL DESCRIPTION | 3-201 | |
| 3.5.8.9 | IVA MOBILITY AIDS | 3-201 | |
| 3.5.8.10 | PORTABLE SHELL FOOT LOOPS | 3-203 | |
| 3.5.8.11 | FLUID SYSTEMS SERVICER INTERFACE | 3-204 | |
| 3.5.8.11.1 | GENERAL | 3-204 | |
| 3.5.8.11.2 | mechanical/structural interFACE | 3-204 | |
| 3.5.8.11.3 | electrical power interFACE | 3-207 | |
| 3.5.8.11.4 | thermal interFACE | 3-207 | |
| 3.5.8.11.5 | FLUID INTERFACE | 3-207 | |
| 3.5.8.11.6 | VACUUM INTERFACE | 3-207 | |
| 3.5.8.12 | ITCS FLUID SAMPLE TOOL | 3-208 | |
| 3.5.8.12.1 | GENERAL | 3-208 | |
| 3.5.8.12.2 | ITCS FLUID SAMPLE TOOL ENVELOPE | 3-210 | |
| 3.5.8.12.3 | MECHANICAL INTERFACE | 3-210 | |
| 3.5.8.12.4 | MASS OF ITCS SAMPLE TOOL | 3-210 | |
| 3.5.8.12.5 | FLUID INTERFACES | 3-210 | |
| 3.5.8.12.5.1 | PHYSICAL INTERFACE | 3-210 | |
| 3.5.8.12.5.2 | ITCS FLUID SAMPLE TOOL FLOW CHARACTERISTICS | 3-212 | |
| 3.5.8.12.5.3 | INTERFACE PRESSURE | 3-212 | |
| 3.5.8.12.5.4 | NOMINAL FLOW | 3-212 | |
| 3.5.8.12.5.5 | INTERFACE TEMPERATURE | 3-212 | |
| 3.5.8.12.5.6 | SAMPLING VOLUME | 3-213 | |
| 3.5.8.13 | ANTIMICROBIAL APPLICATOR | 3-213 | |
| 3.5.8.13.1 | GENERAL | 3-213 | |
| 3.5.8.13.2 | ENVELOPES | 3-213 | |
| 3.5.8.13.3 | MECHANICAL INTERFACE | 3-213 | |
| 3.5.8.13.4 | MASS | 3-213 | |
| 3.5.8.13.5 | FLUID INTERFACES | 3-216 | |
| 3.5.8.13.5.1 | PHYSICAL INTERFACE | 3-216 | |
| 3.5.8.13.5.2 | FLUID VOLUME | 3-216 | |
| 3.5.8.13.5.3 | ANTIMICROBIAL APPLICATOR FLOW CHARACTERISTICS | 3-217 | |
| 3.5.8.13.5.4 | INTERFACE PRESSURE | 3-217 | |
| 3.5.8.13.5.5 | INTERFACE TEMPERATURE | 3-218 | |
| 3.5.8.13.5.6 | NOMINAL MASS FLOW RATE | 3-218 | |
| 3.5.8.14 | ITCS COOLANT MAINTENANCE ASSEMBLY | 3-218 | |
| 3.5.8.14.1 | GENERAL | 3-218 | |
| 3.5.8.14.2 | ENVELOPES | 3-219 | |
| 3.5.8.14.3 | MECHANICAL INTERFACE | 3-220 | |
| 3.5.8.14.4 | MASS | 3-221 | |
| 3.5.8.14.5 | FLUID INTERFACES | 3-221 | |
| 3.5.8.14.5.1 | PHYSICAL INTERFACE | 3-221 | |
| 3.5.8.14.5.2 | FLUID VOLUME | 3-221 | |
| 3.5.8.14.5.3 | ITCS COOLANT MAINTENANCE ASSEMBLY FLOW CHARACTERISTICS | 3-221 | |
| 3.5.8.14.5.4 | INTERFACE PRESSURE | 3-222 | |
| 3.5.8.14.5.5 | INTERFACE TEMPERATURE | 3-222 | |
| 3.5.8.14.5.6 | NOMINAL MASS FLOW RATE | 3-222 | |
| 3.5.8.14.5.7 | ICMA CANISTER LOADING | 3-222 | |
| 3.5.9 | US PORTABLE COMPUTER SYSTEM WORKSTATION | 3-223 | |
| 3.5.9.1 | US PCS−WS POWER DRAW | 3-223 | |
| 3.5.9.2 | THERMAL PROPERTIES | 3-223 | |
| 3.5.9.3 | COOLING MODE | 3-223 | |
| 3.5.9.4 | RADIATIVE AREA | 3-223 | |
| 3.5.10 | POWER AND DATA GRAPPLE FIXTURE | 3-223 | |
| 3.5.10.1 | GENERAL | 3-226 | |
| 3.5.10.1.1 | MASS | 3-226 | |
| 3.5.10.2 | STRUCTURAL | 3-226 | |
| 3.5.10.2.1 | MOUNTING PLATE STIFFNESS | 3-226 | |
| 3.5.10.3 | MECHANICAL | 3-226 | |
| 3.5.10.3.1 | POWER AND DATA GRAPPLE FIXTURE | 3-226 | |
| 3.5.10.4 | PDGF FUNCTIONAL INTERFACES | 3-226 | |
| 3.5.10.4.1 | PDGF POWER INTERFACES | 3-228 | |
| 3.5.10.4.1.1 | FUNCTIONAL DESCRIPTION | 3-228 | |
| 3.5.10.4.1.2 | POWER SPECIFICATION | 3-228 | |
| 3.5.10.4.1.3 | GROUNDING AND ISOLATION | 3-228 | |
| 3.5.10.4.1.4 | BONDING | 3-228 | |
| 3.5.10.4.1.5 | PROTECTION | 3-228 | |
| 3.5.10.4.1.6 | POWER CONNECTOR DEFINITION | 3-228 | |
| 3.5.10.4.1.7 | POWER CONTROL | 3-229 | |
| 3.5.10.4.2 | PDGF DATA INTERFACES | 3-229 | |
| 3.5.11 | CREW HEALTH CARE SYSTEM EQUIPMENT | 3-229 | |
| 3.5.11.1 | CREW HEALTH CARE SYSTEM EQUIPMENT ENVELOPES | 3-229 | |
| 3.5.11.2 | DELETED | 3-229 | |
| 3.5.11.3 | STRUCTURAL | 3-230 | |
| 3.5.11.4 | MECHANICAL | 3-230 | |
| 3.5.11.4.1 | MECHANICAL ATTACHMENTS | 3-230 | |
| 3.5.11.4.1.1 | DELETED | 3-230 | |
| 3.5.11.4.1.2 | RACK SEAT TRACK MECHANICAL ATTACHMENTS | 3-230 | |
| 3.5.11.4.1.3 | CREW HEALTH CARE SYSTEM MECHANICAL ATTACHMENTS TO SEAT TRACKS | 3-230 | |
| 3.5.11.4.2 | CREW HEALTH CARE SYSTEM LOCATIONS | 3-230 | |
| 3.5.11.5 | CREW HEALTH CARE SYSTEM INTERFACES | 3-230 | |
| 3.5.11.5.1 | CREW HEALTH CARE SYSTEM EQUIPMENT POWER INTERFACE | 3-230 | |
| 3.5.11.5.1.1 | CONCEPTUAL LAYOUT | 3-230 | |
| 3.5.11.5.1.2 | NOMINAL POWER REQUIREMENTS | 3-230 | |
| 3.5.11.5.2 | CREW HEALTH CARE SYSTEM DATA INTERFACE | 3-232 | |
| 3.5.11.5.2.1 | CREW HEALTH CARE SYSTEM DATA INTERFACE FUNCTIONAL DESCRIPTION | 3-232 | |
| 3.5.11.5.2.2 | CHECS NETWORK CHARACTERISTICS | 3-232 | |
| 3.5.11.5.2.2.1 | DELETED | 3-233 | |
| 3.5.11.5.2.2.2 | BUS COUPLER AND BUS TERMINATION | 3-233 | |
| 3.5.11.5.2.2.3 | SIGNAL CHARACTERISTICS | 3-233 | |
| 3.5.11.5.3 | CREW HEALTH CARE THERMAL INTERFACE | 3-234 | |
| 3.5.12 | PAYLOAD ETHERNET HUB/GATEWAY | 3-234 | |
| 3.5.12.1 | GENERAL | 3-234 | |
| 3.5.12.1.1 | MASS | 3-234 | |
| 3.5.12.1.1.1 | CENTER OF GRAVITY | 3-234 | |
| 3.5.12.2 | STRUCTURAL | 3-234 | |
| 3.5.12.2.1 | MOUNTING PLATE STIFFNESS | 3-234 | |
| 3.5.12.3 | MECHANICAL | 3-236 | |
| 3.5.12.3.1 | PAYLOAD ETHERNET HUB/GATEWAY (PEHG) MECHANICAL I/F’s | 3-236 | |
| 3.5.12.3.2 | BONDING | 3-236 | |
| 3.5.12.4 | THERMAL | 3-239 | |
| 3.5.12.4.1 | TOUCH TEMPERATURE | 3-239 | |
| 3.5.12.4.2 | COOLING METHOD | 3-239 | |
| 3.5.12.4.3 | EMISSIVITY | 3-239 | |
| 3.5.12.5 | ENVIRONMENT | 3-240 | |
| 3.5.12.5.1 | MECHANICAL/THERMAL ENVIRONMENT | 3-240 | |
| 3.5.12.5.2 | EMC AND POWER QUALITY | 3-240 | |
| 3.5.12.5.3 | CONTAMINATION | 3-240 | |
| 3.5.12.6 | FUNCTIONAL INTERFACES | 3-240 | |
| 3.5.12.6.1 | ELECTRICAL POWER | 3-240 | |
| 3.5.12.6.2 | LAN CABLING TO PEHG | 3-240 | |
| 3.5.12.6.3 | LAN CABLING TO P/L INTERFACE | 3-241 | |
| 3.5.12.6.3.1 | NUMBER OF LAN INTERFACES | 3-241 | |
| 3.5.12.6.3.2 | ELECTRICAL CHARACTERISTICS | 3-241 | |
| 3.5.12.6.3.3 | LAN CABLING LENGTHS | 3-241 | |
| 3.5.12.6.4 | PEHG CONNECTOR INTERFACE | 3-241 | |
| 3.5.12.6.5 | PAYLOAD LAN−2 INTERFACE SCHEMATIC | 3-241 | |
| 3.5.13 | OPS LAN | 3-243 | |
| 3.5.13.1 | GENERAL | 3-243 | |
| 3.5.13.2 | OPS LAN CABLING | 3-243 | |
| 3.5.13.3 | OPS LAN INTERFACE SCHEMATIC | 3-244 | |
| 3.5.13.4 | OPS LAN INTERFACE CONNECTORS | 3-244 | |
| 3.5.14 | JOINT STATION LAN EXTENSIONS TO APM | 3-245 | |
| 3.5.14.1 | LAN ACCESSIBILITY FOR PWS OPERATIONAL DATA | 3-245 | |
| 3.5.14.2 | JOINT STATION LAN (ESA_STATION) INTERFACE DIAGRAM | 3-246 | |
| 3.6 | SOFTWARE INTERFACES | 3-247 | |
| 3.6.1 | INTRODUCTION | 3-247 | |
| 3.6.1.1 | GENERAL DESCRIPTION | 3-247 | |
| 3.6.1.2 | INTERFACE CONTROL DOCUMENT CONVENTIONS | 3-247 | |
| 3.6.1.2.1 | NOTATION | 3-247 | |
| 3.6.1.2.2 | INTERFACE CONTROL DOCUMENT DATA REPRESENTATION CONVENTION | 3-249 | |
| 3.6.1.2.2.1 | PARAMETER STRUCTURE | 3-249 | |
| 3.6.1.2.2.2 | INTERFACE CONTROL DOCUMENT NOMENCLATURE | 3-250 | |
| 3.6.1.2.2.3 | DATA TRANSMISSION | 3-250 | |
| 3.6.1.3 | COMMON DATA STANDARDS | 3-251 | |
| 3.6.1.3.1 | GENERAL | 3-251 | |
| 3.6.1.3.2 | IDENTIFICATION | 3-251 | |
| 3.6.1.3.3 | DATA TYPES, REPRESENTATION AND STRUCTURE | 3-252 | |
| 3.6.1.3.3.1 | OVERVIEW | 3-252 | |
| 3.6.1.3.3.2 | BASIC TYPES | 3-253 | |
| 3.6.1.3.3.2.1 | THE OCTET | 3-253 | |
| 3.6.1.3.3.2.2 | SIGNED INTEGERS | 3-253 | |
| 3.6.1.3.3.2.3 | UNSIGNED INTEGERS | 3-254 | |
| 3.6.1.3.3.2.4 | FLOATING POINT | 3-254 | |
| 3.6.1.3.3.2.5 | FIXED POINT | 3-254 | |
| 3.6.1.3.3.2.6 | ENUMERATION TYPE | 3-254 | |
| 3.6.1.3.3.3 | DERIVED TYPES | 3-254 | |
| 3.6.1.3.3.3.1 | BOOLEAN | 3-254 | |
| 3.6.1.3.3.3.2 | END ITEM IDENTIFIER | 3-254 | |
| 3.6.1.3.3.3.3 | CHARACTER | 3-255 | |
| 3.6.1.3.3.3.4 | BITSET | 3-255 | |
| 3.6.1.3.3.3.5 | DURATION | 3-255 | |
| 3.6.1.3.3.4 | STRUCTURED TYPES | 3-255 | |
| 3.6.1.3.3.4.1 | STRINGS | 3-255 | |
| 3.6.1.3.3.4.2 | TIME CODES | 3-255 | |
| 3.6.1.3.3.4.2.1 | CCSDS UNSEGMENTED TIME CODE | 3-255 | |
| 3.6.1.3.3.4.2.2 | BROADCAST TIME MESSAGE CONTENT/FORMAT | 3-256 | |
| 3.6.1.3.4 | ENGINEERING UNITS | 3-257 | |
| 3.6.1.3.4.1 | GENERAL | 3-257 | |
| 3.6.1.3.4.2 | ROUNDING AND CONVERSION FACTOR DATA TYPES | 3-258 | |
| 3.6.2 | DATA MANAGEMENT COMMUNICATION INTERFACES (LOGICAL INTERFACES) | 3-258 | |
| 3.6.2.1 | GENERAL DESCRIPTION | 3-258 | |
| 3.6.2.2 | STANDARD PROTOCOLS | 3-258 | |
| 3.6.2.2.1 | 1553B DATA EXCHANGE PROTOCOL | 3-258 | |
| 3.6.2.2.1.1 | USE OF MIL−STD 1553B BROADCAST | 3-259 | |
| 3.6.2.2.1.2 | USE OF MIL−STD 1553B ’TRANSMIT DATA’ AND ’RECEIVE DATA’ | 3-259 | |
| 3.6.2.2.1.3 | USE OF STANDARD COMMAND AND DATA LOAD INTERFACES | 3-259 | |
| 3.6.2.2.1.3.1 | COMMAND PROCESSING OVERVIEW | 3-259 | |
| 3.6.2.2.1.3.2 | COMMAND PROCESSING REQUIREMENTS − SSMB | 3-261 | |
| 3.6.2.2.1.3.3 | COMMAND PROCESSING − APM | 3-262 | |
| 3.6.2.2.1.3.3.1 | COMMAND PROCESSING − VTC | 3-262 | |
| 3.6.2.2.1.3.3.2 | COMMAND PROCESSING − APM (NON VTC) | 3-262 | |
| 3.6.2.2.1.4 | USE OF DATA LOAD AND DATA DUMP | 3-262 | |
| 3.6.2.2.1.5 | USE OF NORMAL AND EXTENDED DATA DUMP TRANSFER | 3-263 | |
| 3.6.2.2.1.5.1 | DATA DUMP − SSMB | 3-263 | |
| 3.6.2.2.1.5.2 | DATA DUMP − APM | 3-264 | |
| 3.6.2.2.2 | CONSULTATIVE COMMITTEE ON SPACE DATA SYSTEMS (CCSDS) PROTOCOLS | 3-265 | |
| 3.6.2.2.2.1 | GENERAL DESCRIPTION | 3-265 | |
| 3.6.2.2.2.2 | CCSDS PATH SERVICE | 3-265 | |
| 3.6.2.2.2.2.1 | PATH SERVICE PDU | 3-265 | |
| 3.6.2.2.2.2.2 | CP−PDU VERSION | 3-266 | |
| 3.6.2.2.2.2.3 | CP−PDU TYPE | 3-266 | |
| 3.6.2.2.2.2.4 | CP−PDU SECONDARY HEADER FLAG | 3-266 | |
| 3.6.2.2.2.2.5 | CP−PDU APPLICATION PROCESS ID | 3-267 | |
| 3.6.2.2.2.2.6 | CP−PDU SEQUENCE FLAGS | 3-268 | |
| 3.6.2.2.2.2.7 | CP−PDU SEQUENCE COUNT | 3-268 | |
| 3.6.2.2.2.2.8 | CP−PDU PACKET LENGTH FIELD | 3-269 | |
| 3.6.2.2.2.2.9 | CP−PDU USER DATA FIELD | 3-269 | |
| 3.6.2.3 | USE OF LOGICAL INTERFACES ON PHYSICAL INTERFACES | 3-269 | |
| 3.6.2.3.1 | ESSENTIAL COMMAND AND DATA INTERFACE | 3-269 | |
| 3.6.2.3.1.1 | LOGICAL INTERFACE SCOPE | 3-269 | |
| 3.6.2.3.1.2 | STANDARD DATA EXCHANGE PROFILING | 3-269 | |
| 3.6.2.3.1.3 | CCSDS PATH SERVICING PROFILING | 3-270 | |
| 3.6.2.3.2 | SYSTEM DATA INTERFACE | 3-270 | |
| 3.6.2.3.2.1 | LOGICAL INTERFACE SCOPE | 3-270 | |
| 3.6.2.3.2.2 | STANDARD DATA EXCHANGE PROFILING | 3-270 | |
| 3.6.2.3.2.3 | CCSDS PATH SERVICING PROFILING | 3-271 | |
| 3.6.2.3.3 | DOWNLINK VIA TDRSS | 3-272 | |
| 3.6.2.3.3.1 | HIGH RATE S−BAND DOWNLINK VIA TDRSS | 3-272 | |
| 3.6.2.3.3.1.1 | APM DOWNLINK TELEMETRY PACKETS | 3-273 | |
| 3.6.2.3.3.1.2 | NORMAL DATA DUMP PACKETS | 3-275 | |
| 3.6.2.3.3.1.3 | EXTENDED DATA DUMP PACKETS | 3-275 | |
| 3.6.2.3.3.2 | LOW RATE S−BAND VIA TDRSS | 3-275 | |
| 3.6.2.3.3.3 | KU−BAND DOWNLINK VIA TDRSS | 3-277 | |
| 3.6.2.4 | INTERFACE PERFORMANCE | 3-277 | |
| 3.6.2.4.1 | ESSENTIAL COMMAND AND DATA INTERFACE | 3-277 | |
| 3.6.2.4.1.1 | STANDARD DATA EXCHANGE | 3-277 | |
| 3.6.2.4.1.2 | CCSDS PATH SERVICE | 3-277 | |
| 3.6.2.4.2 | SYSTEM DATA INTERFACE | 3-277 | |
| 3.6.2.4.2.1 | STANDARD DATA EXCHANGE | 3-277 | |
| 3.6.2.4.2.2 | CCSDS PATH SERVICE | 3-278 | |
| 3.6.3 | COMMAND AND DATA INTERFACE (FUNCTIONAL INTERFACES) | 3-278 | |
| 3.6.3.1 | GENERAL DESCRIPTION | 3-278 | |
| 3.6.3.2 | STANDARD FOR FUNCTIONAL INTERFACES | 3-280 | |
| 3.6.3.2.1 | STANDARD PACKET STRUCTURE | 3-280 | |
| 3.6.3.2.1.1 | COMMON PACKET STRUCTURE | 3-280 | |
| 3.6.3.2.1.1.1 | TIME FIELD | 3-280 | |
| 3.6.3.2.1.1.2 | USER DATA CONTROL FIELD | 3-280 | |
| 3.6.3.2.1.1.2.1 | TIME ID | 3-281 | |
| 3.6.3.2.1.1.2.2 | CHECKSUM INDICATOR | 3-281 | |
| 3.6.3.2.1.1.2.3 | SPARE | 3-281 | |
| 3.6.3.2.1.1.2.4 | PACKET TYPE | 3-281 | |
| 3.6.3.2.1.1.3 | PACKET ID | 3-282 | |
| 3.6.3.2.1.1.4 | DATA FIELD | 3-283 | |
| 3.6.3.2.1.1.5 | CHECKSUM FIELD | 3-283 | |
| 3.6.3.2.1.2 | CP_PDU SECONDARY HEADER PROFILING | 3-283 | |
| 3.6.3.2.1.2.1 | PROFILING FOR ESSENTIAL COMMAND AND DATA INTERFACE | 3-283 | |
| 3.6.3.2.1.2.2 | PROFILING FOR SYSTEM COMMAND AND DATA INTERFACE | 3-285 | |
| 3.6.3.2.1.3 | COMMAND PACKET STRUCTURE SPECIFICS | 3-286 | |
| 3.6.3.2.1.3.1 | MONITORING CONTROL COMMANDS | 3-286 | |
| 3.6.3.2.1.3.2 | DELETED | 3-292 | |
| 3.6.3.2.1.3.3 | TELEMETRY PACKET ENABLE/DISABLE COMMAND | 3-292 | |
| 3.6.3.2.1.3.4 | VTC DISCRETE H/W STIMULI | 3-292 | |
| 3.6.3.2.1.3.5 | VTC RAW H/W STIMULI | 3-307 | |
| 3.6.3.2.1.3.6 | VTC INTEGER H/W STIMULI | 3-307 | |
| 3.6.3.2.1.3.7 | ACS CONTROL | 3-307 | |
| 3.6.3.2.1.3.8 | SMOKE SENSOR BIT ENABLE | 3-312 | |
| 3.6.3.2.1.4 | DATA PACKET STRUCTURE SPECIFICS | 3-312 | |
| 3.6.3.2.1.4.1 | VTC DATA PACKET STRUCTURE | 3-312 | |
| 3.6.3.2.1.4.2 | MMC SNCD DATA PACKET STRUCTURE SPECIFICS | 3-315 | |
| 3.6.3.2.2 | STANDARD FOR INTERACTIONS | 3-317 | |
| 3.6.3.2.2.1 | STANDARD INTERACTION SEQUENCE | 3-317 | |
| 3.6.3.2.2.2 | STANDARD FOR CALL PACKETS | 3-317 | |
| 3.6.3.2.2.3 | STANDARD FOR RESPONSE PACKETS | 3-318 | |
| 3.6.3.2.2.3.1 | RESPONSE DATA STANDARD PART | 3-318 | |
| 3.6.3.2.2.3.2 | RESPONSE DATA SPECIFIC PART | 3-321 | |
| 3.6.3.2.2.4 | STANDARD FOR DATA DELIVERY INTERACTIONS | 3-321 | |
| 3.6.3.2.3 | APPLICATION PROCESS IDENTIFIER (APID) SETS | 3-321 | |
| 3.6.3.2.3.1 | SSMB TO APM INTERELEMENT SYSTEM APIDS | 3-321 | |
| 3.6.3.2.3.2 | SSMB TO APM INTERELEMENT PAYLOAD APIDS | 3-322 | |
| 3.6.3.2.4 | STANDARD FOR CCSDS PACKET ROUTING | 3-322 | |
| 3.6.3.3 | FUNCTIONAL INTERFACES SPECIFICATION | 3-322 | |
| 3.6.3.3.1 | SYSTEM ANCILLARY DATA | 3-322 | |
| 3.6.3.3.1.1 | APM HARDWIRED DATA DISTRIBUTION | 3-323 | |
| 3.6.3.3.2 | SELECTED NON−CRITICAL DATA | 3-323 | |
| 3.6.3.3.3 | RECONFIGURATION REQUESTS | 3-328 | |
| 3.6.3.3.3.1 | LOAD SHEDDING | 3-328 | |
| 3.6.3.3.3.2 | PAYLOAD SUPPORT | 3-329 | |
| 3.6.3.3.3.3 | MODE CHANGE COMMANDS | 3-329 | |
| 3.6.3.3.3.4 | (INTENTIONALLY LEFT BLANK) | 3-331 | |
| 3.6.3.3.3.5 | APM PROVIDED INTERFACE | 3-331 | |
| 3.6.3.3.3.5.1 | LOAD SHEDDING | 3-332 | |
| 3.6.3.3.3.5.2 | LOSS OF THERMAL CAPABILITY | 3-335 | |
| 3.6.3.3.3.5.3 | MODE CHANGE | 3-336 | |
| 3.6.3.3.3.5.4 | PAYLOAD SUPPORT | 3-343 | |
| 3.6.3.3.4 | VITAL DATA MANAGEMENT | 3-350 | |
| 3.6.3.3.4.1 | VTC MODE DEFINITION | 3-350 | |
| 3.6.3.3.4.1.1 | VTC INITIALISATION | 3-351 | |
| 3.6.3.3.4.2 | VTC FAILURE MANAGEMENT | 3-352 | |
| 3.6.3.3.4.3 | VTC DATA ACQUISITION | 3-352 | |
| 3.6.3.3.4.4 | VTC TELEMETRY | 3-370 | |
| 3.6.3.3.4.5 | VTC COMMAND DISTRIBUTION | 3-370 | |
| 3.6.3.3.4.6 | TWO−STAGE COMMANDS | 3-372 | |
| 3.6.3.3.4.6.1 | SSMB HANDLING OF VTC TWO−STAGE COMMANDS | 3-374 | |
| 3.6.3.3.4.7 | VTC COMMAND SEQUENCES | 3-375 | |
| 3.6.3.3.4.7.1 | CONTROL OF VTC COMMAND SEQUENCES | 3-375 | |
| 3.6.3.3.4.8 | EMERGENCY, WARNING AND CAUTION (EWAC) | 3-376 | |
| 3.6.3.3.4.8.1 | EMERGENCY DATA | 3-376 | |
| 3.6.3.3.4.8.1.1 | SMOKE SENSOR EMERGENCY | 3-377 | |
| 3.6.3.3.4.8.1.2 | PAYLOAD EMERGENCY | 3-378 | |
| 3.6.3.3.4.8.1.3 | MANUAL EMERGENCY ALARM | 3-379 | |
| 3.6.3.3.4.8.1.4 | AMMONIA LEAKAGE EMERGENCY ALARM | 3-379 | |
| 3.6.3.3.4.8.2 | WARNING AND CAUTION DATA | 3-379 | |
| 3.6.3.3.4.8.3 | APM EMERGENCY, WARNING, AND CAUTION TEXT MESSAGES | 3-381 | |
| 3.6.3.3.4.9 | APM SAFING COMMANDS | 3-391 | |
| 3.6.3.3.4.10 | MAL PANEL CONTROL | 3-391 | |
| 3.6.3.3.4.10.1 | DELETED | 3-391 | |
| 3.6.3.3.4.10.2 | SPACE STATION EWAC | 3-391 | |
| 3.6.3.3.4.10.3 | MAL PANEL TEST | 3-391 | |
| 3.6.3.3.4.10.4 | ALARM−TONE RESET | 3-392 | |
| 3.6.3.3.4.11 | POWER CONTROL | 3-392 | |
| 3.6.3.3.4.12 | APM DEPRESSURIZATION | 3-392 | |
| 3.6.3.3.4.13 | VALVE CONTROL | 3-393 | |
| 3.6.3.3.4.13.1 | IMV VALVE CONTROL | 3-393 | |
| 3.6.3.3.4.13.2 | SNIFFER LINE VALVE CONTROL | 3-393 | |
| 3.6.3.3.4.13.3 | CONDENSATE WATER LINE VALVE CONTROL | 3-393 | |
| 3.6.3.3.4.13.4 | POSITIVE PRESSURE RELIEF INHIBIT VALVES CONTROL | 3-393 | |
| 3.6.3.3.4.13.5 | VACUUM AND VENTING VALVE CONTROL | 3-393 | |
| 3.6.3.3.4.14 | WATER LOOP CONTROL | 3-393 | |
| 3.6.3.3.4.15 | CABIN/IMV FAN CONTROL | 3-394 | |
| 3.6.3.3.4.16 | APM ISOLATION FROM SSMB | 3-394 | |
| 3.6.3.3.4.17 | (INTENTIONALLY LEFT BLANK) | 3-398 | |
| 3.6.3.3.4.18 | (INTENTIONALLY LEFT BLANK) | 3-398 | |
| 3.6.3.3.4.19 | (INTENTIONALLY LEFT BLANK) | 3-398 | |
| 3.6.3.3.4.20 | SSMB TO VTC INTERFACE CCSDS PACKET DEFINITIONS | 3-398 | |
| 3.6.3.3.4.20.1 | SELECT VTC MODE | 3-399 | |
| 3.6.3.3.4.20.2 | NOTIFY VTC MODE CHANGE | 3-399 | |
| 3.6.3.3.4.20.3 | SWITCHING OF MAL PANEL LAMPS | 3-400 | |
| 3.6.3.3.4.20.4 | DELETED | 3-400 | |
| 3.6.3.3.4.20.5 | FIRE INDICATORS CONTROL | 3-400 | |
| 3.6.3.3.4.20.6 | TELEMETRY PACKETS ENABLE / DISABLE | 3-401 | |
| 3.6.3.3.4.20.7 | VTC RESET | 3-402 | |
| 3.6.3.3.4.20.8 | VTC INITIAL MODE DEFINITION | 3-402 | |
| 3.6.3.3.4.20.9 | VTC OPERATING MODE CHANGE | 3-403 | |
| 3.6.3.3.4.20.10 | VTC OPERATING MODE TRANSITION | 3-403 | |
| 3.6.3.3.4.20.11 | VTC MONITORING CONTROL | 3-404 | |
| 3.6.3.3.4.20.12 | DELETED | 3-405 | |
| 3.6.3.3.4.20.13 | VTC DISCRETE HW STIMULI | 3-405 | |
| 3.6.3.3.4.20.14 | VTC RAW HW STIMULI | 3-406 | |
| 3.6.3.3.4.20.15 | VTC INTEGER HW STIMULI | 3-407 | |
| 3.6.3.3.4.20.16 | ENABLE / DISABLE DMC RECONFIGURATION FUNCTION | 3-408 | |
| 3.6.3.3.4.20.17 | ENABLE / DISABLE 1553 RECONFIGURATION FUNCTION | 3-408 | |
| 3.6.3.3.4.20.18 | (INTENTIONALLY LEFT BLANK) | 3-408 | |
| 3.6.3.3.4.20.19 | START/TERMINATE AN AUTOMATIC COMMAND SEQUENCE | 3-408 | |
| 3.6.3.3.4.20.20 | STOP/RESUME AN AUTOMATIC COMMAND SEQUENCE | 3-409 | |
| 3.6.3.3.4.20.21 | ENABLE / DISABLE AN AUTOMATIC COMMAND SEQUENCE | 3-409 | |
| 3.6.3.3.4.20.22 | SELECT BOOT CONFIGURATION OF AN SPC | 3-410 | |
| 3.6.3.3.4.20.23 | SMOKE SENSOR BIT ENABLE | 3-411 | |
| 3.6.3.3.4.20.24 | VITAL BUS SWITCHOVER | 3-411 | |
| 3.6.3.3.4.20.25 | CANCEL A TWO−STAGE COMMAND | 3-412 | |
| 3.6.3.3.4.20.26 | FIRE A TWO−STAGE COMMAND | 3-412 | |
| 3.6.3.3.4.20.27 | UPDATE TIME REFERENCE | 3-412 | |
| 3.6.3.3.4.20.28 | SYNCHRO EVENT BROADCAST | 3-412 | |
| 3.6.3.3.5 | PAYLOAD LATERAL DATA TRANSFERS | 3-413 | |
| 3.6.3.3.5.1 | INTERFACE FUNCTION | 3-413 | |
| 3.6.3.3.5.2 | INTERFACE PERFORMANCE | 3-419 | |
| 3.6.3.3.6 | DELETED | 3-419 | |
| 3.6.3.3.6.1 | DELETED | 3-419 | |
| 3.6.3.3.6.2 | DELETED | 3-419 | |
| 3.6.3.3.6.3 | DELETED | 3-419 | |
| 3.6.3.3.6.4 | DELETED | 3-419 | |
| 3.6.3.3.7 | FUNCTIONAL USE OF DATA LOAD AND DATA DUMP | 3-419 | |
| 3.6.3.3.8 | SYNCHRONIZATION AND DELIVERY OF TIME TO THE APM | 3-420 | |
| 3.6.4 | JSL INTERFACE | 3-420 | |
| 3.6.4.1 | GENERAL DESCRIPTION | 3-420 | |
| 3.6.4.2 | SSMB TO APM JSL INTERFACE | 3-421 | |
| 3.6.4.2.1 | TRANSMISSION SETTING | 3-421 | |
| 3.6.4.2.2 | ETHERNET ADDRESSING | 3-421 | |
| 3.6.4.2.3 | NETWORK LOOPS | 3-421 | |
| 3.6.4.2.4 | SSMB TRAFFIC ISOLATION | 3-421 | |
| 3.6.4.2.4.1 | VLAN | 3-421 | |
| 3.6.4.2.4.1.1 | VLAN ID | 3-421 | |
| 3.6.4.2.4.1.2 | VLAN TAGS | 3-421 | |
| 3.6.4.2.5 | IPV4 | 3-422 | |
| 3.6.4.2.6 | TRAFFIC FORWARDING | 3-422 | |
| 3.6.4.2.6.1 | IPV FORWARDING | 3-422 | |
| 3.6.4.2.6.2 | ANTIVIRUS DATABASE FORWARDING | 3-422 | |
| 3.6.4.2.6.3 | esa jsl payload traffic forwarding | 3-422 | |
| 3.7 | AVIONICS CONNECTOR/HARNESS INTERFACE DATA | 3-423 | |
| 3.7.1 | BULKHEAD AVIONICS CONNECTOR DEFINITION | 3-423 | |
| 3.7.1.1 | CONNECTOR LOCATION | 3-423 | |
| 3.7.1.2 | CONNECTOR ASSIGNMENT | 3-423 | |
| 3.7.1.3 | DELETED | 3-425 | |
| 3.7.1.4 | CONNECTOR PIN ASSIGNMENT | 3-425 | |
| 3.7.1.5 | DELETED | 3-432 | |
| 3.7.2 | APM STANDARD UTILITY PANEL CONNECTOR DEFINITION | 3-432 | |
| 3.7.2.1 | CONNECTOR LOCATION | 3-432 | |
| 3.7.2.2 | CONNECTOR ASSIGNMENT | 3-432 | |
| 3.7.2.3 | DELETED | 3-435 | |
| 3.7.2.4 | CONNECTOR PIN ASSIGNMENT | 3-435 | |
| 3.7.3 | PDGF CONNECTOR DEFINITION | 3-449 | |
| 3.7.3.1 | CONNECTOR LOCATION | 3-449 | |
| 3.7.3.2 | CONNECTOR ASSIGNMENT | 3-450 | |
| 3.7.3.3 | INTERFACE WIRING DIAGRAM | 3-451 | |
| 3.7.3.4 | CONNECTOR PIN ASSIGNMENT | 3-452 | |
| 3.7.4 | NODE 2 UTILITY OUTLET PANEL CONNECTOR DEFINITION | 3-453 | |
| 3.7.4.1 | CONNECTOR LOCATION | 3-453 | |
| 3.7.4.2 | CONNECTOR ASSIGNMENT | 3-453 | |
| 3.7.5 | PEHG CONNECTOR DEFINITION | 3-455 | |
| 3.7.5.1 | CONNECTOR LOCATION | 3-455 | |
| 3.7.5.2 | CONNECTOR ASSIGNMENT | 3-455 | |
| 3.7.5.3 | CONNECTOR PIN ASSIGNMENT | 3-455 | |
| 3.7.5.4 | DELETED | 3-461 |
APPENDIX
| a | abbreviations and Acronyms | a-1 |
| b | glossary of terms | b-1 |
| c | index of tbds, tbcs, and tbrs | c-1 |
| d | DELETED | d-1 |
| e | issue sheets | e-1 |
| f | software operational interface description | f-1 |
| g | APM EXTERNAL PAYLOAD FACILITY INTERFACES | g-1 |
TABLE
| 3.1.5.1−1 | ATTACHED PRESSURIZED MODULE MASS PROPERTIES | 3-27 | |
| 3.3.6.1−1 | STANDARD UTILITY PANEL CONNECTORS | 3-39 | |
| 3.3.6.2−1 | NODE 2 UTILITY OUTLET PANEL CONNECTORS FOR APM PWS AND JSL ER | 3-42 | |
| 3.5.1.1.1.1−1 | OUTPUT PERFORMANCE OF ONE POWER FEEDER (NORMAL OPERATIONS) | 3-49 | |
| 3.5.1.1.1.1−2 | OPERATING STATES | 3-49 | |
| 3.5.1.1.1.2.2.1−1 | CURRENT LIMIT AND TRIP | 3-56 | |
| 3.5.1.1.1.2.2.2−1 | OVERCURRENT THRESHOLD | 3-57 | |
| 3.5.1.3−1 | CABLE BUNDLE EMC CLASSIFICATiON | 3-60 | |
| 3.5.1.6.2−1 | OUTPUT PERFORMANCE OF SUP POWER OUTLET | 3-61 | |
| 3.5.1.6.3−1 | POWER LOAD INTERFERENCE | 3-65 | |
| 3.5.2.1.3.1−1 | APM EWACS INTERFACE (2 Pages) | 3-75 | |
| 3.5.2.3.2−1 | 1553 NETWORK CHARACTERISTICS | 3-81 | |
| 3.5.2.3.2.3−1 | COMMAND & CONTROL BUS SIGNAL CHARACTERISTICS | 3-83 | |
| 3.5.2.4.1.1−1 | VTC AND PDU HARDWIRED INTERFACE DATA DEFINITION (2 Pages) | 3-86 | |
| 3.5.2.4.2.1−1 | 15 VOLT COMMAND CHARACTERISTICS | 3-92 | |
| 3.5.2.4.2.2−1 | BI−LEVEL DATA CHARACTERISTICS (CONTACT STATUS SENSOR) | 3-95 | |
| 3.5.2.4.2.3−1 | ANALOG DATA CHARACTERISTICS | 3-98 | |
| 3.5.2.5.2.1.4−1 | SUBADDRESS table | 3-102 | |
| 3.5.2.5.2.1.5−1 | MODE CODES | 3-103 | |
| 3.5.2.5.3.1.2−1 | RECEIVE DATA MESSAGE FORMAT | 3-109 | |
| 3.5.2.5.3.2.2−1 | TRANSMIT DATA MESSAGE FORMAT | 3-110 | |
| 3.5.2.5.5−1 | SPT PROTOCOL PARAMETER (2 pages) | 3-116 | |
| 3.5.2.5.6.1−1 | RECONFIGURATION PERFORMANCE | 3-118 | |
| 3.5.2.6.4−1 | OPTICAL CHARACTERISTICS APM TO SSMB FOR DATA | 3-125 | |
| 3.5.2.6.4.2−1 | HRM OUTPUT SIGNAL CHARACTERISTICS APM TO SSMB | 3-127 | |
| 3.5.2.7.1.1−1 | CABLE CHARACTERISTICS | 3-134 | |
| 3.5.2.7.2.2−1 | 1553 NETWORK CHARACTERISTICS | 3-138 | |
| 3.5.2.7.2.5−1 | US PAYLOAD BUS SIGNAL CHARACTERISTICS (FOR REFERENCE ONLY) | 3-139 | |
| 3.5.2.8.2−1 | OPTICAL CHARACTERISTICS oF HIGH RATE DATA PAYLOAD INTERFACES | 3-140 | |
| 3.5.3.2.1.1−1 | ATTACHED PRESSURIZED MODULE ACTIVE THERMAL CONTROL SYSTEM INTERFACE PERFORMANCE CHARACTERISTICS NOMINAL OPERATIONS | 3-144 | |
| 3.5.3.2.1.2−1 | ATTACHED PRESSURIZED MODULE ACTIVE THERMAL CONTROL SYSTEM INTERFACE PERFORMANCE CHARACTERISTICS OFF NOMINAL CASE (a) | ||
| (MT LOOP FAILURE, JEM REQUIRES THERMAL SINK) | 3-146 | ||
| 3.5.3.2.1.2−2 | ATTACHED PRESSURIZED MODULE ACTIVE THERMAL CONTROL SYSTEM INTERFACE PERFORMANCE CHARACTERISTICS OFF NOMINAL CASE (b) | ||
| (lT LOOP FAILURE, JEM REQUIRES THERMAL SINK) | 3-147 | ||
| 3.5.3.3.2−1 | ATTACHED PRESSURIZED MODULE TO SPACE STATION ACTIVE THERMAL CONTROL SYSTEM PHYSICAL INTERFACES | 3-150 | |
| 3.5.3.4.1−1 | LOCAL INTERFACES ATTACHED PRESSURIZED MODULE TO SPACE STATION MANNED BASE COMPONENTS | 3-151 | |
| 3.5.3.4.1−2 | DATA NECESSARY FOR THE CALCULATION OF THE EVA AIDS THERMAL | ||
| INTERFACE TO THE ATTACHED PRESSURIZED MODULE | 3-152 | ||
| 3.5.4.2.1.1−1 | HARDWIRED AUDIO INTERFACE CHARACTERISTICS | 3-156 | |
| 3.5.4.2.1.1−2 | SPACE STATION MANNED BASE/ATTACHED PRESSURIZED MODULE AUDIO | ||
| FIBER CHARACTERISTICS | 3-156 | ||
| 3.5.4.2.2.2−1 | INTERNATIONAL SPACE STATION ATTACHED PRESSURIZED MODULE INTRAVEHICULAR ANTENNA ASSEMBLY CABLE CHARACTERISTICS | 3-158 | |
| 3.5.4.3−1 | APM CAMERA COMMAND BIT PATTERN | 3-163 | |
| 3.5.4.3−3 | MIL−STD 1553 GENERIC CAMERA COMMANDS FIELD LIMITS | 3-164 | |
| 3.5.4.3.1−1 | VIDEO SIGNAL CHARACTERISTICS | 3-165 | |
| 3.5.4.3.1−2 | OPTICAL CHARACTERISTICS APM TO SSMB AND SSMB TO APM FOR VIDEO | 3-165 | |
| 3.5.4.3.1−3 | VIDEO AND SYNC FIBER OPTIC POWER LEVELS AT APM/SSMB INTERFACE | 3-166 | |
| 3.5.4.3.2−1 | APM CAMERA ADDRESSES | 3-166 | |
| 3.5.6.3−1 | ISS EVA STANDARD TOOLS FOR APM USE | 3-180 | |
| 3.5.7−1 | TCS AND ECLSS JUMPER DEFINITION | 3-187 | |
| 3.5.7−2 | ECLSS FLUID INTERFACE JUMPER PRESSURE LOSSES | 3-187 | |
| 3.5.7.1.1.1−1 | INTERMODULE VENTILATION SUPPLY TO APM INTERFACE PERFORMANCE CHARACTERISTICS | 3-188 | |
| 3.5.7.1.2.1−1 | INTERMODULE VENTILATION AIR RETURN TO SPACE STATION MANNED BASE INTERFACE PERFORMANCE CHARACTERISTICS (ATTACHED PRESSURIZED MODULE IN NOMINAL CONDITIONS) | 3-193 | |
| 3.5.7.3.1−1 | ATMOSPHERE SAMPLING (MAJOR CONSTITUENTS) INTERFACE PERFORMANCE CHARACTERISTICS | 3-194 | |
| 3.5.7.5−1 | ECLSS CONNECTOR DATA | 3-195 | |
| 3.5.8.8−1 | ISS IVA SPECIAL TOOLS IN THE APM | 3-201 | |
| 3.5.8.11.5−1 | FSS TO APM FLUID INTERFACES | 3-207 | |
| 3.5.8.11.6−1 | FSS TO APM VACUUM INTERFACES | 3-208 | |
| 3.5.9.1−1 | US−PCS THERMAL PROPERTIES | 3-223 | |
| 3.5.10.4.1.2−1 | PDGF TO APM POWER INTERFACE CHARACTERISTICS (NORMAL OPERATIONS) | 3-228 | |
| 3.5.11.1−1 | CHECS EQUIPMENT ENVELOPES | 3-229 | |
| 3.5.11.5.2.2−1 | 1553 NETWORK CHARACTERISTICS | 3-233 | |
| 3.5.11.5.2.2.3−1 | CHECS BUS SIGNAL CHARACTERISTICS (FOR REFERENCE ONLY) | 3-233 | |
| 3.5.12.4.2-1 | pehg thermal interface parameters | 3-239 | |
| 3.5.12.6.2−1 | LAN CABLE CHARACTERISTICS | 3-241 | |
| 3.5.12.6.3.3−1 | CABLE PARAMETERS | 3-241 | |
| 3.5.12.6.5−1 | PEHG CHANNEL TO USER ASSIGNMENT | 3-243 | |
| 3.5.13.2−1 | LAN CABLE CHARACTERISTICS | 3-244 | |
| 3.6.1.3.3.4.2.2−1 | CCSDS SEGMENTED TIME CODE | 3-257 | |
| 3.6.2.2.2.2.5−1 | DELETED | 3-268 | |
| 3.6.2.2.2.2.5−2 | DELETED | 3-268 | |
| 3.6.2.3.1.3−1 | DELETED | 3-270 | |
| 3.6.2.3.2.3−1 | CP−PDU PACKET SIZES | 3-272 | |
| 3.6.2.3.3.2−1 | S−BAND TELEMETRY PROFILES AT LOW DATA RATE | 3-277 | |
| 3.6.3.2.1.3−1 | VTC COMMAND PATHNAMES (2 pages) | 3-287 | |
| 3.6.3.2.1.3.1−1 | SPECIFICS OF THE VTC MONITORING CONTROL COMMANDS (3 pages) | 3-289 | |
| 3.6.3.2.1.3.3−1 | VTC TM PACKETS | 3-292 | |
| 3.6.3.2.1.3.4−1 | SPECIFICS OF THE VTC DISCRETE H/W STIMULI COMMAND (14 Pages) | 3-293 | |
| 3.6.3.2.1.3.7−1 | VTC AUTOMATED COMMAND SEQUENCES (4 pages) | 3-308 | |
| 3.6.3.2.1.3.8 −1 | APM SMOKE SENSORS | 3-312 | |
| 3.6.3.2.1.4.1−1 | VTC NOMINAL PACKET STRUCTURE | 3-315 | |
| 3.6.3.2.3.1−1 | DELETED | 3-322 | |
| 3.6.3.3.2−1 | SELECTED NON−CRITICAL DATA (4 pages) | 3-324 | |
| 3.6.3.3.3.3−1 | APM VS STATION LEVEL MODES COMPATIBILITY | 3-330 | |
| 3.6.3.3.4.3−1 | VTC MEASUREMENTS AVAILABLE IN THE C&C MDM (17 Pages) | 3-353 | |
| 3.6.3.3.4.5−1 | VTC COMMANDING CAPABILITIES | 3-372 | |
| 3.6.3.3.4.8.3−1 | APM EMERGENCY, WARNING, AND CAUTION TEXT MESSAGE (8 pages) | 3-382 | |
| 3.6.3.3.4.8.3−2 | APM THERMAL LOAD SHED ANNUNCIATIONS | 3-390 | |
| 3.6.3.3.4.16−1 | TRIGGER EVENTS FOR APM ISOLATION UPON CONFIRMED CABIN AREA FIRE | 3-395 | |
| 3.6.3.3.4.16−2 | TRIGGER EVENTS FOR APM ISOLATION UPON CONFIRMED ISPR FIRE OR | ||
| CENTER AISLE P/L FIRE | 3-396 | ||
| 3.6.3.3.4.16−3 | TRIGGER EVENTS FOR APM ISOLATION UPON P/L TOXIC SPILLAGE | 3-397 | |
| 3.6.3.3.4.16−4 | TRIGGER EVENTS FOR APM ISOLATION UPON APM C&W MAL PANEL ALARM | 3-397 | |
| 3.6.3.3.4.16−5 | TRIGGER DATA FOR APM ISOLATION UPON NH3 LEAK TOXIC ATMOSPHERE ALARM | 3-397 | |
| 3.6.3.3.5.1-1 | apm pAYLOAD aNCILLARY dATA (4 pages) | 3-415 | |
| 3.6.3.3.5.2−1 | TRANSACTION RATES | 3-419 | |
| 3.6.4.2.4.1.1−1 | VLAN ID ASSIGNMENTS | 3-421 | |
| 3.7.1.2−1 | BULKHEAD CONNECTOR ASSIGNMENTS | 3-424 | |
| 3.7.1.4−1 | J01 (J98) − POWER FEEDER APM 2 | 3-425 | |
| 3.7.1.4−2 | J02 (J99) − POWER FEEDER APM 1 | 3-425 | |
| 3.7.1.4−3 | J04 (J91) − HARDWIRED INSTRUMENTATION ML − R | 3-425 | |
| 3.7.1.4−4 | J05 (J95) − HARDWIRED INSTRUMENTATION − HO − R | 3-426 | |
| 3.7.1.4−5 | J06 (J78) − HARDWIRED INSTRUMENTATION HO − N | 3-427 | |
| 3.7.1.4−6 | J07 (J93) − 1553B BUSES B/APM PWS DATA | 3-428 | |
| 3.7.1.4−7 | J08 (J81) − 1553B BUSES A | 3-429 | |
| 3.7.1.4−8 | J09 (J79)− INTERVEHICULAR ANTENNA ASSEMBLY (IAA) | 3-429 | |
| 3.7.1.4−9 | J10 (J83) − FIBER OPTIC 1 | 3-430 | |
| 3.7.1.4−10 | J11 (J90) − FIBER OPTIC 2 | 3-431 | |
| 3.7.1.4−11 | J12 (J82) − HARDWIRED INSTRUMENTATION ML − N | 3-431 | |
| 3.7.1.4−12 | J03 (J77) ETHERNET | 3-432 | |
| 3.7.2.2−1 | SUP CONNECTOR ASSIGNMENT (2 Pages) | 3-433 | |
| 3.7.2.4−1 | APM STANDARD UTILITY PANEL 1 −J01 | 3-435 | |
| 3.7.2.4−2 | APM STANDARD UTILITY PANEL 1 −J02 | 3-436 | |
| 3.7.2.4−3 | APM STANDARD UTILITY PANEL 1 −J03 | 3-437 | |
| 3.7.2.4−4 | APM STANDARD UTILITY PANEL 1 −J05 | 3-437 | |
| 3.7.2.4−5 | APM STANDARD UTILITY PANEL 1 −J07 | 3-438 | |
| 3.7.2.4−6 | APM STANDARD UTILITY PANEL 1 −J09 | 3-438 | |
| 3.7.2.4−7 | APM STANDARD UTILITY PANEL 2 −J01 | 3-439 | |
| 3.7.2.4−8 | APM STANDARD UTILITY PANEL 2 −J02 | 3-440 | |
| 3.7.2.4−9 | APM STANDARD UTILITY PANEL 2 −J03 | 3-441 | |
| 3.7.2.4−10 | APM STANDARD UTILITY PANEL 2 −J05 | 3-441 | |
| 3.7.2.4−11 | APM STANDARD UTILITY PANEL 2 −J09 | 3-442 | |
| 3.7.2.4−12 | APM STANDARD UTILITY PANEL 3 −J01 | 3-442 | |
| 3.7.2.4−13 | APM STANDARD UTILITY PANEL 3 −J02 | 3-443 | |
| 3.7.2.4−14 | APM STANDARD UTILITY PANEL 3 −J03 | 3-444 | |
| 3.7.2.4−15 | APM STANDARD UTILITY PANEL 3 −J05 | 3-444 | |
| 3.7.2.4−16 | APM STANDARD UTILITY PANEL 3 −J09 | 3-445 | |
| 3.7.2.4−17 | APM STANDARD UTILITY PANEL 4 −J01 | 3-445 | |
| 3.7.2.4−18 | APM STANDARD UTILITY PANEL 4 −J02 | 3-446 | |
| 3.7.2.4−19 | APM STANDARD UTILITY PANEL 4 −J03 | 3-447 | |
| 3.7.2.4−20 | APM STANDARD UTILITY PANEL 4 −J05 | 3-447 | |
| 3.7.2.4−21 | APM STANDARD UTILITY PANEL 4 −J07 | 3-448 | |
| 3.7.2.4−22 | APM STANDARD UTILITY PANEL 4 −J09 | 3-448 | |
| 3.7.3.2-1 | pdgf connector assignment | 3-450 | |
| 3.7.3.2-2 | pdgf harness/apm connector assignment | 3-450 | |
| 3.7.3.4-1 | J05 - PDGF DATA Connector -A | 3-452 | |
| 3.7.3.4-2 | j07 - pdgf pwr connector -A | 3-452 | |
| 3.7.3.4-3 | J06 - PDGF DATA Connector -B | 3-452 | |
| 3.7.3.4-4 | j08- pdgf pwr connector -b | 3-452 | |
| 3.7.3.4-5 | j400/p400 - pdgf pwr connector -a | 3-452 | |
| 3.7.3.4-6 | j401/p401 - pdgf pwr connector -b | 3-452 | |
| 3.7.4.1-1 | node 2 utility outlet panel connector assignment | 3-453 | |
| 3.7.4.2-1 | node 2 utility outlet panel power connector pin assignment (j3) | 3-453 | |
| 3.7.4.2-2 | node 2 utility outlet panel lan data connector pin assignment (j4) | 3-454 | |
| 3.7.5.2−1 | PEHG CONNECTOR ASSIGNMENT | 3-455 | |
| 3.7.5.3−1 | J01 PEHG POWER CONNECTOR | 3-455 | |
| 3.7.5.3−2 | J02 PEHG MIL−STD−1553 CONNECTOR | 3-456 | |
| 3.7.5.3−3 | J03 PEHG ETHERNET CONNECTOR (3 pages) | 3-457 | |
| 3.7.5.3−4 | J04 PEHG ETHERNET CONNECTOR | 3-460 | |
| 3.7.5.3−5 | J05 PEHG ETHERNET CONNECTOR | 3-460 |
FIGURE
| 3.1.1-1 | SPACE STATION-TO-COLUMBUS ATTACHED PRESSURIZED MODULE INTERFACE DESCRIPTION CONCEPTual LAYOUT | 3-2 | |
| 3.1.3-1 | COLUMBUS ATTACHED PRESSURIZED MODULE REFERENCE COORDINATE SYSTEM | 3-4 | |
| 3.1.3-2 | International Space Station Attached Pressurized Module | ||
| Coordinate Reference Frame | 3-5 | ||
| 3.1.4−1 | COLUMBUS MODULE ENVELOPE DIMENSIONS WITHOUT EXTERNAL PAYLOADS | 3-7 | |
| 3.1.4-2 | EXTERNAL PAYLOAD FIELD OF VIEW SH. 1/2 | 3-9 | |
| 3.1.4-2 | EXTERNAL PAYLOAD FIELD OF VIEW SH. 2/2 | 3-10 | |
| 3.1.4-3 | APM−NODE2 DURING BERTHING | 3-11 | |
| 3.1.4-4 | APM−NODE2 IN BERTHED CONDITION | 3-12 | |
| 3.1.4.1.3-1 | APM/SPDM INTERFACE SH. 1/3 | 3-13 | |
| 3.1.4.1.3−1 | APM/SPDM INTERFACE SH. 2/3 | 3-14 | |
| 3.1.4.1.3−1 | APM/SPDM INTERFACE SH. 3/3 | 3-15 | |
| 3.1.4.1.4.1.2−1 | COLUMBUS AMATEUR RADIO ANTENNA LOCATION (SHEET 1 OF 2) | 3-17 | |
| 3.1.4.1.4.1.2−1 | COLUMBUS AMATEUR RADIO ANTENNA LOCATION (SHEET 2 OF 2) | 3-18 | |
| 3.1.4.1.4.2.3−1 | COLUMBUS AIS AND ARISS ANTENNa lOCATIONS (SHEET 1 OF 3) | 3-19 | |
| 3.1.4.1.4.2.3−1 | COLUMBUS AIS AND ARISS ANTENNA LOCATIONS (SHEET 2 OF 3) | 3-20 | |
| 3.1.4.1.4.2.3−1 | COLUMBUS AIS AND ARISS ANTENNA LOCATIONS (SHEET 3 OF 3) | 3-21 | |
| 3.1.4.1.4.2.4−1 | RF CABLE ROUTING TO VHF ANTENNAS ON COLUMBUS | 3-22 | |
| 3.1.4.1.5.1−1 | EXTERNAL INTERFACE LOCATIONS FOR PARKING PAYLOAD AND COLUMBUS TERMINAL (SHEET 1 OF 3) | 3-24 | |
| 3.1.4.1.5.1−1 | EXTERNAL INTERFACE LOCATIONS FOR PARKING PAYLOAD AND COLUMBUS TERMINAL (SHEET 2 OF 3) | 3-25 | |
| 3.1.4.1.5.1−1 | EXTERNAL INTERFACE LOCATIONS FOR PARKING PAYLOAD AND COLUMBUS TERMINAL (SHEET 3 OF 3) | 3-26 | |
| 3.2.3.1−1 | LOCATIONS OF RACKS AND RACK SEAT TRACKS IN THE APM | 3-30 | |
| 3.3.3.1−1 | UTILITY PENETRATION LAYOUT OF NODE 2, STARBOARD VIEW LOOKING PORT | 3-32 | |
| 3.3.3.1−2 | UTILITY PENETRATION LAYOUT OF ATTACHED PRESSURIZED MODULE, STARBOARD VIEW LOOKING PORT | 3-33 | |
| 3.3.3.1-3 | UTILITY PENETRATION LAYOUT OF NODE 2, STARBOARD VIEW LOOKING PORT | 3-34 | |
| 3.3.3.1−4 | UTILITY PENETRATION LAYOUT OF ATTACHED PRESSURIZED MODULE, STARBOARD VIEW LOOKING PORT | 3-35 | |
| 3.3.3.1−4.1 | UTILITY PENETRATION LAYOUT (BULKHEAD CUTOUT DETAIL) | 3-36 | |
| 3.3.5.4−1 | MECHANICAL ATTACHMENT TO RACK SEAT TRACKS (1 OF 2) | 3-38 | |
| 3.3.5.4−1 | MECHANICAL ATTACHMENT TO RACK SEAT TRACKS (2 OF 2) | 3-38 | |
| 3.3.6.1−1 | APM STANDARD UTILITY PANEL | 3-40 | |
| 3.3.6.2−1 | NODE 2 UTILITY PANEL LAYOUT (FOR REFERENCE) | 3-41 | |
| 3.3.6.3.1−1 | US PORTABLE WORKSTATION HARNESS CONFIGURATION | 3-43 | |
| 3.3.6.3.2−1 | APM PORTABLE WORKSTATION HARNESS CONFIGURATION | 3-44 | |
| 3.3.6.3.3−1 | US STATION SUPPORT COMPUTER HARNESS CONFIGURATION | 3-45 | |
| 3.3.6.4.1−1 | US JSL ER HARNESS CONFIGURATION | 3-46 | |
| 3.5.1−1 | ELECTRICAL POWER SYSTEM INTERFACE FUNCTIONAL DIAGRAM | 3-48 | |
| 3.5.1.1.1.1−1 | POWER SOURCE IMPEDANCE AT ISS/APM INTERFACE (SINGLE DDCU) | 3-51 | |
| 3.5.1.1.1.1−2 | SOURCE OUTPUT IMPEDANCE (PARALLEL DDCU’S) | 3-52 | |
| 3.5.1.1.1.1−3 | LOAD IMPEDANCE, COMPOSITE (EXPECTED RANGE IN THE MANNED NOMINAL MODE WITH TYPICAL ISPR LOADING) | 3-53 | |
| 3.5.1.1.1.1−4 | APM LOAD IMPEDANCE. CORE SYSTEM (EXPECTED RANGE IN THE MANNED NOMINAL MODE) | 3-54 | |
| 3.5.1.1.1.1−5 | DELETED | 3-55 | |
| 3.5.1.1.1.2.1−1 | POWER FEEDER OVERVOLTAGE BEHAVIOR | 3-55 | |
| 3.5.1.1.1.4−1 | CORE STATION−GENERATED NARROW BAND VOLTAGE EMISSION OF | ||
| INDIVIDUAL SPECTRAL COMPONENTS (FROM SSMB) AT APM / NODE 2 INTERFACE | 3-58 | ||
| 3.5.1.1.2.2−1 | APM−GENERATED NARROW BAND VOLTAGE EMISSION, OF INDIVIDUAL | ||
| SPECTRAL COMPONENTS | 3-60 | ||
| 3.5.1.6.2−1 | POWER SOURCE IMPEDANCE AT SUP POWER OUTLET | 3-63 | |
| 3.5.1.6.2−2 | SYSTEM VOLTAGE EMISSIONS | 3-64 | |
| 3.5.1.6.2−3 | SUP POWER OUTLET PROTECTION CHARACTERISTICS | 3-64 | |
| 3.5.1.6.2−4 | SUP POWER OUTLET GFI AC CHARACTERISTICS | 3-65 | |
| 3.5.1.6.3−1 | VOLTAGE EMISSIONS | 3-66 | |
| 3.5.1.6.3-2 | load transient limits | 3-67 | |
| 3.5.1.6.3−3 | LINE IMPEDANCE SIMULATION NETWORK | 3-67 | |
| 3.5.2.1.1−1 | AVIONICS SYSTEM FUNCTIONAL INTERFACE IDENTIFICATION | 3-70 | |
| 3.5.2.1.4.2−1 | AUDIO FUNCTIONAL INTERFACE BETWEEN APM AND SSMB | 3-78 | |
| 3.5.2.2−1 | DATA MANAGEMENT SYSTEM INTERFACES | 3-80 | |
| 3.5.2.3.1−1 | ISS C&C BUSES INTERFACES | 3-82 | |
| 3.5.2.4.1−1 | HARDWIRED INTERFACES BLOCK DIAGRAM | 3-85 | |
| 3.5.2.4.2.1−1 | 15V COMMAND, PRINCIPLE INTERFACE CIRCUIT DIAGRAM | 3-89 | |
| 3.5.2.4.2.1−2 | PULSE COMMAND TIMING AT THE SSMB/APM INTERFACE | 3-90 | |
| 3.5.2.4.2.1−3 | 15V COMMAND INTERFACE LOGIC LEVELS | 3-91 | |
| 3.5.2.4.2.2−1 | BI−LEVEL DATA INTERFACE, PRINCIPLE CIRCUIT DIAGRAM | 3-94 | |
| 3.5.2.4.2.2−2 | BI−LEVEL DATA INTERFACE LOGIC LEVEL | 3-96 | |
| 3.5.2.4.2.3−1 | ANALOG INPUT, PRINCIPLE INTERFACE CIRCUIT DIAGRAM | 3-97 | |
| 3.5.2.5.1−1 | DATA MESSAGE FORMATS | 3-100 | |
| 3.5.2.5.2.1−1 | COMMAND WORD | 3-100 | |
| 3.5.2.5.2.2−1 | STATUS WORD | 3-106 | |
| 3.5.2.5.2.3−1 | DATA WORD FORMAT | 3-108 | |
| 3.5.2.5.3.1−1 | RECEIVE DATA MESSAGE | 3-109 | |
| 3.5.2.5.3.2−1 | TRANSMIT DATA MESSAGE | 3-110 | |
| 3.5.2.5.5−1 | SPT TIMING DIAGRAM | 3-113 | |
| 3.5.2.5.5−2 | 100MS 1553B I/O PROFILE WITH MMC ON CB INT2 | 3-114 | |
| 3.5.2.5.5−3 | 100 MS 1553B I/O PROFILE WITH MMC ON CB INT1 | 3-115 | |
| 3.5.2.5.6−1 | C&DH BUS CHANNEL MANAGEMENT | 3-119 | |
| 3.5.2.6−1 | OPTICAL DATA LINKS INTERFACE BLOCK DIAGRAM | 3-122 | |
| 3.5.2.6.4.1−1 | OPTICAL TAXI LINK WAVE FORM ENVELOPE OF APM OUTPUT | 3-126 | |
| 3.5.2.6.5.2−1 | APM TO SSMB HIGH RATE DATA LINK (BITSTREAM PACKETIZATION MODE) | 3-128 | |
| 3.5.2.6.5.2−2 | APM TO SSMB HIGH RATE DATA LINK (BITSTREAM PASS THROUGH MODE) | 3-128 | |
| 3.5.2.6.5.2.1−1 | HRDL PROTOCOL STATE DIAGRAM | 3-129 | |
| 3.5.2.6.5.2.6.1−1 | HRDL BITSTREAM FORMAT | 3-131 | |
| 3.5.2.7.1−1 | APM PORTABLE WORKSTATION FUNCTIONAL DIAGRAM | 3-134 | |
| 3.5.2.7.1.2−1 | APM LAN EXTENSION INTERFACE CIRCUIT DIAGRAM | 3-135 | |
| 3.5.2.7.2−1 | US PAYLOAD BUS LAYOUT | 3-137 | |
| 3.5.3.1−1 | SPACE STATION MANNED BASE TO ATTACHED PRESSURIZED MODULE ACTIVE THERMAL CONTROL SYSTEM INTERFACE FUNCTIONAL DIAGRAM (1 OF 2) | 3-142 | |
| 3.5.3.1−1 | SPACE STATION MANNED BASE TO ATTACHED PRESSURIZED MODULE ACTIVE THERMAL CONTROL SYSTEM INTERFACE FUNCTIONAL DIAGRAM (2 OF 2) | 3-143 | |
| 3.5.3.2.1.1−1 | SSMB−NODE TO APM LT BUS INTERFACE HEAT LOAD CAPABILITY | 3-145 | |
| 3.5.3.2.1.1−2 | SSMB−NODE 2 TO APM MT BUS INTERFACE HEAT LOAD CAPABILITY | 3-146 | |
| 3.5.3.3.1−1 | LOW TEMPERATURE IH/X INTERFACE WATER PRESSURE DROP VERSUS | ||
| WATER MASS FLOW (NOMINAL AND OFF−NOMINAL CASES) | 3-148 | ||
| 3.5.3.3.1−2 | MODERATE TEMPERATURE IH/X INTERFACE WATER PRESSURE DROP VERSUS WATER MASS FLOW (NOMINAL AND OFF−NOMINAL CASES) | 3-149 | |
| 3.5.4.1−1 | COMMUNICATIONS AND TRACKING INTERFACE FUNCTIONAL DIAGRAM | 3-154 | |
| 3.5.4.2.1−1 | HARDWIRED AUDIO INTERFACES | 3-155 | |
| 3.5.4.2.2.1−1 | IAA LOCATION IN APM | 3-158 | |
| 3.5.4.3−1 | VIDEO INTERFACES BLOCK DIAGRAM | 3-160 | |
| 3.5.4.3−2 | TELEVISION CAMERA COMMAND FORMAT FOR SYNC/CONTROL AND VIDEO SIGNALS | 3-161 | |
| 3.5.4.3−3 | VERTICAL INTERVAL LINE 15 VIDEO TIME TAG SIGNAL | 3-162 | |
| 3.5.4.3−4 | SCU MIL−STD 1553 GENERIC CAMERA COMMAND MESSAGE | 3-163 | |
| 3.5.6−1 | DELETED | 3-167 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 1/6) | 3-168 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 2/6) | 3-169 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 3/6) | 3-170 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 4/6) | 3-171 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 5/6) | 3-172 | |
| 3.5.6.1−1 | LOCATION OF EVA AIDS INTERFACES ON APM CYLINDER (Sheet 6/6) | 3-173 | |
| 3.5.6.1−2 | EVA AIDS INTERFACE LOCATIONS ON APM PORT CONE | 3-174 | |
| 3.5.6.1−3 | EVA AIDS INTERFACE LOCATIONS ON APM STARBOARD CONE | 3-175 | |
| 3.5.6.1−4 | EVA HANDRAILS FOR HCUs | 3-176 | |
| 3.5.6.2−1 | WIF ADAPTER MECHANICAL INTERFACE | 3-177 | |
| 3.5.6.2−2 | NODE2 WIF FW7 FOR SSRMS/APM PDGF EVA RELEASE | 3-178 | |
| 3.5.6.4−1 | “T” HANDLE RECEPTACLE MECHANICAL INTERFACE | 3-182 | |
| 3.5.6.5.3−1 | GROUND INSTALLED HANDRAIL MECHANICAL INTERFACE | 3-183 | |
| 3.5.6.5.4−1 | SEAT−TRACK MECHANICAL INTERFACE | 3-184 | |
| 3.5.7−1 | ENVIRONMENTAL CONTROL AND LIFE SUPPORT SYSTEM FUNCTION INTERFACE DIAGRAM | 3-186 | |
| 3.5.7.1.1.2−1 | SSMB−TO−APM JUMPER CONFIGURATIONS | 3-189 | |
| 3.5.7.1.1.2−2 | APM IMV FEEDTHROUGH FLANGE CONFIGURATION | 3-190 | |
| 3.5.7.1.1.2−3 | SSMB IMV JUMPER DUCT FLANGE CROSS SECTION | 3-191 | |
| 3.5.7.1.1.2−4 | IMV FLANGE DETAILS NODE SIDE | 3-192 |