796455_P1043_FinalDrawings_Vol_18.pdf
PDF 12 MB Posted
- Solicitation number
- N4008521R0052
About this file
This federal contract opportunity solicitation is for a water treatment plant replacement project at Marine Corps Base Camp Lejeune in North Carolina. The solicitation seeks design-build services to construct an 8 million gallon per day membrane filtration water treatment facility to comply with current and future drinking water regulations and address potential saltwater intrusion issues. The project aims to provide an adequate and environmentally compliant potable water supply for domestic, industrial, and fire protection uses at Camp Lejeune. The solicitation was issued by the Naval Facilities Engineering Command on behalf of the Department of the Navy. The solicitation number is N40085-21-R-0052 and responses are due on the date specified.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
IM
E
D
T A
IL
S
RCDN AP
E-801
P -E -8
.d g n
611 704
L E
C T
R
IC
A
NTS
12772246
EJA
JGG / RSF
JAS
C3
SCALE: NTS
A3
SCALE: NTS
A5
SCALE: NTS
LIGHTING PROTECTION
SYSTEM AIR TERMINAL 2
PAD-MOUNTED TRANSFORMER DETAIL
LIGHTNING PROTECTION SYSTEM AIR TERMINAL 2
SECONDARY COMPARTMENT
CONCRETE PAD
GRADE
CURRENT TRANSFORMERS
3-POLE FUSE BLOCK
WHD
#4/0 BARE
GROUND PAD (TYP OF 2)PRIMARY NEUTRAL
BUSHING INSERT
BREAK OIL SWITCH
2 POSITION LOAD
PRIMARY COMPARTMENT
ARRESTERS
SURGE
X0
DDC CIRCUIT
CABLE WELL
CORNER OF PAD.
OF 4, 1 AT EACH
GROUND ROD, TYP
MIN
2'-0"
TERMINATIONS
LOW VOLTAGE CABLE
DEMAND METER
WATTHOUR
EXPULSION FUSES
BAYONET OIL-IMMERSED
FUSES
CURRENT-LIMITING
OIL-IMMERSED
BUSHING WELL
TRANSFORMER
CONNECTOR
LOAD BREAK
SECONDARY CIRCUIT
INSULATION
#4/0, 600V
GRADE.
PAD. MIN 18" BELOW FINISHED
ENCIRCLING ENTIRE CONCRETE
#4/0 BARE COPPER GROUND LOOP
PRIMARY CIRCUIT
COPPER GROUNDING CONDUCTORS
#4/0, 600V INSULATION
SURFACE.
ABOVE THE PROTECTED
MINIMUM OF 10"
4. POINT EXTENDS A
OF THE POINT.
VERTICAL POSITIONING
ADJUST BASE TO ENSURE
CONTRACTOR TO FIELD
SCREWS. INSTALLING
STAINLESS STEEL TEK
WITH FOUR #10 x 1"
POINT BASE. SECURE
3. ALUMINUM STRAP TYPE
STEEL TEK SCREW.
#10 x 1" STAINLESS
SECURE WITH
CABLE FASTENER.
2. ALUMINUM LOOP TYPE
BLUNT TIP.
AIR TERMINAL WITH
1. 5/8" SOLID ALUMINUM
NOTES:
NOTE 1
NOTE 3
NOTE 2
NOTE 4
THE PROTECTED SURFACE
MINIMUM OF 10" ABOVE
5. POINT EXTENDS A
4. ADHESIVE POINT BASE
3. ADHESIVE CABLE HOLDER
PROTECTION CONDUCTOR
2. ALUMINUM LIGHTNING
TIP
TERMINAL WITH BLUNT
1. 5/8" SOLID ALUMINUM
NOTES:
NOTE 2
NOTE 4
NOTE 3
NOTE 1
N O
T E
C1
SCALE: NTS
A1
SCALE: NTS
LIGHTING PROTECTION SYSTEM AIR TERMINAL 1
LIGHTING PROTECTION SYSTEM - DOWN CONDUCTOR
POINT EXTENDS MINIMUM OF 10" ABOVE THE PROTECTED SURFACE.5.
2 FEET MAX FROM EDGE OF ROOF.4.
ALUMINUM STANDING SEAL CLIP.3.
ALUMINUM STANDING SEAM BASE.2.
5/8" SOLID ALUMINUM TERMINAL WITH BLUNT TIP.1.
NOTES:
NOTE 4
NOTE 2
NOTE 3
N O
T E
NOTE 1
ALUMINUM LOOP TYPE CABLE FASTENER SECURE WITH #10 x 1" STAINLESS STEEL TAK SCREW.3.
ALUMINUM STANDING SEAM CLIP.2.
ALUMINUM SECONDARY BONDING LUG SECURE WITH #10 x 1" STAINLESS STEEL TAK SCREW.1.
NOTES:
NOTE 1
NOTE 3
NOTE 2
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
N T
C
O
R E
N O
R F
O L
K
V
IR
G
IN
IA
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
H
A
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
IE
S
G
IN
E E
R
G
Y S
T E
M
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
B
J E
U N
E J
A C
K S
O N
V
IL
L E
N
796455
License Number F-0699 Tel: 919-875-4311
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-802
-E -8
.d g
612 704
E
C T
R
IC
A
12772247
GFS
C1
C2
SCALE: NTS
C3
SCALE: NTS
A1
SCALE: NTS
FIRE STOP - WALL
NOTE 1
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 2
PN-STI EZDP333GK4.
WALL FILL MATERIAL3.
CABLES2.
FIRESTOP DEVICE1.
NOTES:
RAILING MOUNTED EQUIPMENT SUPPORT
4"
/2
FRONT SIDE
NOTE 1
NOTE 2
NOTE 4
NOTE 7
NOTE 6
NOTE 5
NOTE 3
NOTES:
3/16" PLATE7.
NUTS AND LOCKWASHERS 6.
5/16" DIA U-BOLTS, LENGTH AS REQUIRED5.
1/2" RADIUS4.
DEVICE BOX3.
ROUND EDGES2.
RAILING1.
WITH STEEL MEMBERS AND CONNECTIONS PER SPECIFICATIONS.
AT ALUMINUM RAILING, PROVIDE PROTECTION FOR ALUMINUM IN CONTACT A.
DEVICE MOUNTING - WALL OR COLUMN
NOTES:
FLOOR OR PLATFORM8.
PIPE STRAP7.
CONDUIT6.
WIRING DEVICE OR ELECTRICAL EQUIPMENT 5.
WALL OR COLUMN 4.
FOR CONTROL STATIONS MOUNT AT 4'-0"±3.
ANCHORS. LARGER BOXES SHALL BE SUPPORTED BY AT LEAST FOUR.
BOXES 6 INCHES SQUARE AND LESS SHALL BE SUPPORTED BY TWO2.
MOUNT ENCLOSURE ON 1/2" SPACERS OF 1/2" SCHEDULE 80 PVC CONDUIT.1.
NOTE 1 & 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
CONDUIT TO TRAY FITTING
NOTE 2
NOTE 3
NOTE 4
NOTE 1
CONDUIT4.
TRAY SIDE RAILS
3/4" - 1 1/4". ATTACHES TO BASKET
CONDUIT FITTING FITS CONDUIT SIZES 3.
UTP CABLES2.
BASKET TRAY1.
NOTES:
C4
SCALE: NTS
EXTERIOR LIGHT CONTROL DIAGRAM
AREA
TYPICAL FOR:
120VAC
PC
NOTE 1
RELAY
PHOTOCELL
120VAC
OFF
REMOTEHAND
TO PLC600
"IN REMOTE"
OOX
OOX
XOO
PC1
C
STATION (X)
CONTROL
CONTACTOR (Y)
PER PLANS
PANELBOARD
TOLOCATED AT STURCTURE)
CONTROL STATION (X)
PER PLANS
LOADS
TO LIGHTING
TO OTHER CONTROL STATIONS & CONTACTORS
AS REQ'D
CONTACTS
PC1
TO PLC 600
PHOTOCELL INPUT
LOCATED AT CONCENTRATE CLARIFIER BUILDING.2.
BUILDING.
TO CONTROL ALL CONTACTORS. LOCATE RELAY IN ELECTRICAL CONCENTRATE CLARIFIER
PROVIDE RELAY IN A NEMA 12 ENCLOSURE. PROVIDE NUMBER OF CONTACTS SUFFICIENT1.
NOTES:
CONCENTRATE TANK & REPUMP - -
NOTE 2
CONTACTOR (Y)
NOTE 2
PHOTOCELL
SCALE: NTS
EXTERIOR BUILDING LIGHT CONTROL
N
120V OFF
PHOTOCELL
PHOTOCELL
AS SHOWN
ON ENGRAVED PLATE
POSITIONS INDICATED
SWITCH (SL) WITH SWITCH
TYP
LUMINAIRE,
ON
A3 A1
SCALE: NTS
LUMINAIRE MOUNTING
POLE CAP
REMOVABLE
SCHEDULE
PER LUMINAIRE
LUMINAIRE
PLATFORM
CONCRETE
GROUT
POLE MANUFACTURER
FURNISHED BY
MOUNTING BRACKET
PER PLANS
COVER WHERE REQUIRED
AND WETHERPROOF
DUPLEX RECEPTACLE
M
IN
± 6-5/8"
10' POLE
4" SQUARE
SHEAR = 2.3 KIP
MOMENT = 11.5 KIP*FT
LEVEL LOADS
POLE ANCHORAGE DESIGNED FOR THE FOLLOWIG STRENGTH2.
HANDRAILS.
CONTRACTOR SHALL COORDINATE POLE LOCATIONS WITH1.
NOTES:
4-1/2" MIN
M
IN
LEVELING NUTS
BOLTS AND
55 HEAVY HEX
F1554 GRADE
(4) 3/4" DIA ASTM
CAST-IN-PLACE
S L
A B T
H
IC
K N
E S
S
POLE
TURN UP INSIDE
ROUTE IN SLAB,
(2) 3/4" CONDUITS
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-803
-E -8
.d g
613 704
E
C T
R
IC
A
12772248
A1
SCALE: NTS
C4
SCALE: NTS
A4
SCALE: NTS
PEDESTAL MOUNTED DEVICE
ELECTRICAL EQUIPMENT SUPPORT
TYP
3/16
A.
3/16
3" 3"
SECTION
B.
48" MAXIMUM
M A
X
IM
U
10"
1 1/4"
GENERAL NOTES:
NOTES:
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
N O
T E
NOTE 2
NOTE 10
NOTE 9
(4 EACH BASE)
1/2" CONCRETE ANCHORS OR ANCHOR BOLTS WITH LEVELING NUTS,10.
NON-SHRINK GROUT9.
PROVIDE HDPE SPACER BETWEEN ALUMINUM AND CONCRETE, IF ALUMINUM IS USED.8.
LENGTH PER EQUIPMENT REQUIREMENTS.
CHANNEL(4x2.16 IN SEISMIC ZONES 0 AND 1, 6x3.00 IN SEISMIC ZONES 2 AND HIGHER)7.
1/2" RADIUS 6.
1/2" PLATE5.
1/4" PLATE, ROUND EDGES; SIZE PER EQUIPMENT REQUIREMENTS.4.
3/4" RADIUS3.
STRUCTURE ABOVE WHERE REQUIRED BY CALCULATION.
200 LBS, SIZE POSTS AND CONNECTIONS FOR LATERAL LOADS. EXTEND POSTS TO
FOR HEIGHTS EXCEEDING 5'-0" OR WEIGHT OF MOUNTED EQUIPMENT EXCEEDING2.
ABOVE FINISHED GRADE. MINIMUM WIDTH 24 INCHES.
LONGER THAN THE MOUNTING PLATE BY ONE HALF THE HEIGHT OF THE MOUNTING PLATE
AT GRADE WITH #4 BAR @ 12" OC EACH WAY, CENTERED. THE PAD SHALL BE 12 INCHES
WALL OR PLATFORM, FOR YARD LOCATIONS PROVIDE A 6 INCH THICK CONCRETE PAD 1.
USE WASHER AND SPLIT LOCK WASHER UNDER ALL NUTS.
SEE INSTRUMENTATION AND CONTROL DETAILS.
PROVIDE SUN SHIELD FOR INSTRUMENTS AND CONTROL STATIONS WITH LIGHTS,
EQUIPMENT MOUNTING
6"
MIN TWO 1/2" CONCRETE ANCHORS PER POST
CHANNEL POST BASE ATTACH TO FLOOR WITH 11.
CHANNEL PIPE CLAMP10.
MIN 1 5/8"x1 5/8" 12 GAUGE FRAMING CHANNEL9.
1/2" RADIUS8.
HAND SWITCH 7.
1/4" PLATE, SIZE AS REQUIRED, ROUND EDGES6.
CHANNEL SPRING-NUT5.
FLAT PLATE BRACKET4.
ATTACH TO CEILING PURLINS.
MIN 1 5/8"x1 5/8" 12 GAUGE FRAMING CHANNEL, 3.
JUNCTION BOX2.
CONDUIT 1.
NOTES:
GENERAL NOTES:
NOTE 3
NOTE 4
NOTE 5
NOTE 1
NOTE 6
NOTE 7
NOTE 8
NOTE 9
NOTE 10
NOTE 11
NOTE 2
LOADS.
CONNECTIONS FOR VERTICAL AND LATERAL
SIZE SUPPORT POST, CROSS CHANNELS, ANDA.
A.
B.
M A
X
IM
U M
A P
P R
O X
ALL NUTS AND BOLTS.
USE WASHER AND SPLIT-LOCK WASHERS UNDER
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 2
NOTE 7
SHALL BE SUPPORTED BY 2 CHANNELS.
THAN 3 SQUARE FEET OR WIDER THAN 18 INCHES
EQUIPMENT HAVING A FRONTAL AREA GREATER
GRADE7.
(2) 5/8" DIA CONCRETE ANCHORS.6.
PROVIDE HDPE SPACER, IF ALUMINUM IS USED.5.
6" CHANNEL4.
DEVICE3.
CONCRETE WALL2.
EDGES, WELD TO CHANNEL.
PROVIDE 1/4" PLATE, SIZE AS REQUIRED, ROUND 1.
3/16
3/16
10"
PLANOVERSIZED DEVICES
ELEVATION
1 1/4"
M A
X
IM
U M
NOTES:
GENERAL NOTES:
B.
A.
C.
D.
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
NOTE 9
NOTE 1
NOTE 10
1/2" CONCRETE ANCHORS OR ANCHOR BOLTS WITH LEVELING NUTS, TYPICAL OF 4.10.
NON-SHRINK GROUT9.
USED.
PROVIDE HDPE SPACER BETWEEN ALUMINUM AND CONCRETE, IF ALUMINUM IS 8.
C4x2.167.
CONTROL STATION OR OTHER DEVICES.6.
1/4" PLATE, SIZE AS REQUIRED FOR OVERSIZED DEVICES.5.
1/4" MOUNTING PLATE, (18" MAX, WIDTH), ROUND EDGES, 1/2" RADIUS.4.
1/2" PLATE3.
1/2" RADIUS2.
WITH 3#4 REBAR EACH WAY, CENTERED FLOOR OR PLATFORM.
FOR YARD LOCATIONS, PROVIDE 2'-0" SQUARE x 6" THICK CONCRETE PAD AT GRADE1.
INDICATED.
GREATER THAN 2'-0" SQ FT SHALL BE PEDESTAL MOUNTED UNLESS OTHERWISE
CONTROL STATIONS DEVICES AND EQUIPMENT HAVING A FRONTAL AREA NOT
USE WASHERS AND SPLIT-LOCK WASHERS UNDER ALL NUTS.
SEE INSTRUMENTATION AND CONTROL DETAILS.
PROVIDE SUNSHIELDS FOR INSTRUMENTS AND CONTROL STATIONS WITH LIGHTS,
EQUIPMENT MOUNTING PEDESTAL
INSUFFICIENT USE DETAIL E-803, C1
WHERE EQUIPMENT REQUIRES A LARGE BACKPLATE AND A SINGLE SUPPORT LEG IS
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-804
-E -8
.d g
614 704
E
C T
R
IC
A
12772249
A1
SCALE: NTS
C3
SCALE: NTS
A3
SCALE: NTS
CONDUIT SUPPORT ON STRUCTURE
4"
/2 " 1 /4
1/2"
TOP
FRONT SIDE
NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
APPLETON "STN" CONDUIT CONNECTOR.6.
APPLETON "ST" CONDUIT CONNECTOR.5.
FLEXIBLE CONDUIT4.
MATERIAL REQUIREMENTS.
REFERENCE AREA CLASSIFICATION TABLES FOR
3/8" DIA MIN, CONCRETE ANCHOR, AS SPECIFIED. 3.
12 GAUGE METAL 2.
DRILL HOLE, AS REQUIRED FOR CONDUIT FITTING.1.
COVER THIS
COVER THIS
LUG, TYPICAL 8.
SIGNAL LEADS7.
SHRINK TUBING6.
SHIELD5.
GREEN INSULATED WIRE4.
CRIMPED SPLICE CONNECTOR3.
WRAPPED SHIELD 2.
OUTER JACKET 1.
SHRINK TUBING
PORTION WITH
SHRINK TUBING
PORTION WITH
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 1
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 5
NOTE 6
NOTE 6NOTE 7
NOTE 7
NOTE 8
WHERE GROUNDING IS REQUIRED.
TERMINATED IN ACCORDANCE WITH THIS DETAIL
ALL SHIELDED INSTRUMENTATION CABLE SHALL BE A.
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
THAT ONE CONDUIT TO SUPPORT.
THIS DETAIL APPLIES ONLY WHEN THERE IS MORE A.
TABLES FOR MATERIAL REQUIREMENTS.
FORMED CHANNEL. REFERENCE AREA CLASSIFICATION 5.
MATERIAL REQUIREMENTS.
REFERENCE AREA CLASSIFICATION TABLES FOR
3/8" DIA MIN, CONCRETE ANCHOR, AS SPECIFIED. 4.
WALL OR COLUMN3.
CONDUIT2.
CONDUIT CLAMP 1.
M A
X
IM
U M
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
SPLIT LOCK WASHERS UNDER ALL NUTS AND BOLTS.
SUPPORTED BY TWO CHANNELS. INSTALL RING AND
3 SQUARE FEET OR WIDER THAN 18 INCHES SHALL BE
EQUIPMENT HAVING A FRONTAL AREA GREATER THAN A.
FOR MOUNTING TO STRUCTURAL STEEL.
(2) 5/8" CONCRETE ANCHORS. USE (2) 5/8" BOLTS 8.
SPECIFIED, IF ALUMINUM IS USED.
PAINT ALUMINUM IN CONTACT WITH CONCRETE AS 7.
CONDUIT CLAMP6.
C6X10.5 CHANNEL5.
RAILING4.
REQUIRED, ROUND EDGES, WELD TO CHANNEL.
FOR OVERSIZE DEVICE PROVIDE 1/4" PLATE SIZE AS 3.
DEVICE2.
12/" RADIUS1.
FLEXIBLE CONDUIT SUPPORT TERMINATION OF SHIELDED INSTRUMENTATION CABLE
PEDESTAL MOUNTED DEVICE AT RAILING
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-805
-E -8
.d g
615 704
E
C T
R
IC
A
12772250
A1
SCALE: NTS
C3
SCALE: NTS
A3
SCALE: NTS
X X X X X
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 7
NOTE 5
NOTE 6
NOTE 6
NOTE 10
NOTE 8
NOTE 9
NOTES:
GENERAL NOTES:
TOP SLAB/ DECK10.
STRAIN RELIEF CORD GRIP9.
RECOMMENDATIONS.
INSTALL PER MANUFACTURERS
MANUFACTURED BY SIKA CHEMICAL CORP.
CONCRETE SLAB W/SIKADUR HI-MOD GEL AS
HOOK BOLT (5/8" MIN DIA) EPOXY BOLT INTO 8.
CONDUIT SLEEVE (2" MINIMUM)7.
INSULATING BUSHING 6.
[MSC]5.
CORD FITTING4.
JUNCTION BOX3.
STATION AND DISCONNECT ON HANDRAIL.
MOUNT CONDUIT ROUTED TO CONTROL 2.
HANDRAIL1.
M
IN
4" MINIMUM 3" MINIMUM4" MINIMUM
M
IN
IM
U M
NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
X X X X X
NOTES:
INTERIOR
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6NOTE 6
NOTE 7
NOTE 7
NOTE 8
NOTE 9
NOTE 10
SOURCE CABLE5.
ENCLOSURE4.
SPARE CONDUCTORS3.
SPARE TERMINALS AS REQUIRED BY SPECIFICATIONS (25% MINIMUM).
PROVIDE ONE TERMINAL FOR EACH CONDUCTOR ENTERING OR LEAVING "TJB". PROVIDE2.
LOAD CABLES1.
A4
SCALE: NTS
SUBMERSIBLE PUMP W/ REMOTE CONTROL STATION
NOTE 1
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 2
NOTES:
GROUND ROD6.
GROUNDING CONDUCTOR, TYPICAL.5.
GRAVEL4.
GROUNDING WELL3.
TYPE ABG, OR EQUAL.
GROUNDING CONNECTORS: "O-Z/GEDNEY" 2.
GRADE1.
GROUNDING BUSHING4.
METAL CONDUIT3.
EQUIPMENT ENCLOSURE2.
GROUND WIRE1.
NOTES:
GENERAL NOTES:
GROUNDED IN ACCORDANCE WITH THIS DETAIL.
GROUNDED BY THE SPECIFICATIONS SHALL BE
THE ENDS OF ALL CONDUITS REQUIRED TO BE A.
NOTE 1
NOTE 2
NOTE 3
NOTE 4
TERMINAL JUNCTION BOX (TJB)
SUBMERSIBLE PUMP/MIXER CONTROL STATION GROUND TEST WELL CONDUIT GROUNDING
AND PUMPS.
BETWEEN CONTROL STATION, DISCONNECT,
CONDUIT AND CONDUCTOR CONNECTIONS B.
SEE DRAWINGS.
FOR CONTROL STATION MOUNTING DETAILS, A.
MSC10.
CORD FITTING9.
TOP SLAB/DECK 8.
INSULATING BUSHING7.
STRAIN RELIEF CORD GRIP6.
RECOMMENDATIONS.
INSTALL PER MANUFACTURERS
MANUFACTURED BY SIKA CHEMICAL CORP.
CONCRETE SLAB W/SIKADUR HI-MOD GEL AS
HOOK BOLT (5/8" MIN DIA) EPOXY BOLT INTO 5.
CONDUIT SLEEVE (2" MINIMUM)4.
CONTROL STATION SUPPORT, E-803, C13.
TERMINAL JUNCTION BOX (TJB).2.
TERMINAL BLOCKS, E-805, C3.1.
C4
SCALE: NTS
GROUND TRIANGLE
DB
DB
DB
D B
T Y
P
M
IN
CONDUCTOR
GROUNDING
AS SPECIFIED, TYP
GROUND ROD
SEE A3/E-805
GROUND TEST WELL,
GROUNDING PAD
TO TOWER
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-806
-E -8
.d g
616 704
E
C T
R
IC
A
12772251
A1
SCALE: NTS
C3
SCALE: NTS
A3
SCALE: NTS
V A
R
IE
S
PLAN
ELEVATION
NON-METALLIC CONDUIT10.
GROUND CONDUCTOR9.
GROUND BUS BAR8.
FLOOR7.
BUSHING6.
CONNECTION TO CONDUCTOR.
EXOTHERMIC WELD OR COMPRESSION
GROUND CONDUCTOR CONNECTOR.5.
WASHERS. SIZE TO SUIT, TYPICAL.
SILICON BRONZE BOLTS, NUTS AND 4.
WALL3.
SCHEDULE 80 PVC SPACER2.
5/8" ANCHOR BOLT 1.
GENERAL NOTES:
NOTES:
NOTE 1
NOTE 2
NOTE 4
NOTE 5NOTE 5
NOTE 6
NOTE 7
NOTE 10
NOTE 9
NOTE 8
NOTE 3
3/4" 2" 4" 4" 2" 3/4"
LENGTH TO SUIT
NOT TO EXCEED 24".
MAXIMUM SPAN BETWEEN SUPPORTS A.
AS REQUIRED,
MINIMUM
1.5
M
IN
IM
U M
NOTES:
SINGLE RACK
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 2
NOTE 6
GENERAL NOTES:
A.
AS REQUIRED,
M
IN
IM
U M
M
IN
IM
MINIMUM
1.5
GENERAL NOTES:
NOTES:
DOUBLE RACK
NOTE 4
NOTE 5
NOTE 6
NOTE 2
NOTE 3
NOTE 2
NOTE 1
M
IN
IM
U M
20' LONG MINIMUM, 2 TYP
M
IN
IM
U M
NOTES:
AS REQUIRED
BEND AROUND CORNERS
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 1
GROUND BUS BAR CONDUIT RACKING SYSTEM
GROUND ELECTRODE CONDUIT RACKING SYSTEM
BOTTOM OF FOUNDATION 5.
GROUNDING ELECTRODE4.
GROUND BUS BAR, E-806, C13.
GROUND CABLES2.
FINISH GRADE 1.
WITHOUT DISTURBING ADJACENT CONDUITS.
SPACE CONDUIT SUFFICIENTLY TO ALLOW REMOVAL OF ONE CONDUIT
FRAMING CHANNEL.6.
CONDUIT SIZE AS REQUIRED. 5.
BOTTOM OF STEEL OR CONCRETE STRUCTURE.4.
REGISTERED IN THE STATE OF NORTH CAROLINA.
SYSTEM SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER
STRUCTURAL GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING AND SUPPORT
SIZE AS REQUIRED BY SITE SPECIFIC DESIGN CRITERIA ON DRAWING G-008,
3'-0" BELOW, OR GRINNEL FIGURE 52 ATTACHMENT PLATE, SIMILAR. TYPE AND
STRUCTURE, USE UNIVERSAL CONCRETE INSERT, UNISTRUT CHANNEL WITH #4 x
AT STEEL STRUCTURE, USE GRINNEL MALLEABLE BEAM CLAMP. AT CONCRETE 3.
WALL.
SEISMIC BRACE TO ROOF OR FLOOR TOP OF BEAM ABOVE UNLESS BRACED TO
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA.
1. CONDUIT RACKING AND SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED
DESIGN CRITERIA ON DRAWING G-008, STRUCTURAL GENERAL NOTES, AND LEGEND
SUPPORT RODS, CONNECTIONS AND BRACES AS REQUIRED BY SITE SPECIFIC
DETERMINE SPAN AND TYPE OF SUPPORTS, LOCATE SUPPORTS, AND SIZE 2.
BETWEEN CONDUITS.
LENGTH VARIES WITH NUMBER OF CONDUITS TO BE SUPPORTED AND SPACING 1.
CONDUIT SIZE AS REQUIRED.6.
FRAMING CHANNEL.5.
BOTTOM OF STEEL OR CONCRETE STRUCTURE.4.
OF NORTH CAROLINA.
BE DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER REGISTERED IN THE STATE
GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING AND SUPPORT SYSTEM SHALL
REQUIRED BY SITE SPECIFIC DESIGN CRITERIA ON DRAWING G-008, STRUCTURAL
BELOW, OR GRINNEL FIGURE 52 ATTACHMENT PLATE, SIMILAR. TYPE AND SIZE AS
STRUCTURE, USE UNIVERSAL CONCRETE INSERT, UNISTRUT CHANNEL WITH #4 x 3'-0"
AT STEEL STRUCTURE, USE GRINNEL MALLEABLE BEAM CLAMP. AT CONCRETE 3.
BRACE TO ROOF OR FLOOR TOP OF BEAM ABOVE UNLESS BRACED TO WALL.
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA. SEISMIC
RACKING AND SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED
ON DRAWING G-008, STRUCTURAL GENERAL NOTES, AND LEGEND 1. CONDUIT
RODS, CONNECTIONS AND BRACES AS REQUIRED BY SITE SPECIFIC DESIGN CRITERIA
DETERMINE SPAN AND TYPE OF SUPPORTS, LOCATE SUPPORTS, AND SIZE SUPPORT 2.
LENGTH VARIES WITH NUMBER OF CONDUITS TO BE SUPPORTED AND SPACING 1.
DISTURBING ADJACENT CONDUITS.
SPACE CONDUIT SUFFICIENTLY TO ALLOW REMOVAL OF ONE CONDUIT WITHOUT D.
NORTH CAROLINA.
DESIGNED BY A QUALIFIED PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF
GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING AND SUPPORT SYSTEM SHALL BE
REQUIRED BY SITE SPECIFIC DESIGN CRITERIA ON DRAWING G-008, STRUCTURAL
BELOW, OR GRINNEL FIGURE 52 ATTACHMENT PLATE, SIMILAR. TYPE AND SIZE AS
STRUCTURE, USE UNIVERSAL CONCRETE INSERT, UNISTRUT CHANNEL WITH#4 x 3'-0"
AT STEEL STRUCTURE, USE GRINNEL MALLEABLE BEAM CLAMP. AT CONCRETE C.
ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA.
AND SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL
ON DRAWING G-008, STRUCTURAL GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING
RODS, CONNECTIONS AND BRACES AS REQUIRED BY SITE SPECIFIC DESIGN CRITERIA
DETERMINE SPAN AND TYPE OF SUPPORTS, LOCATE SUPPORTS, AND SIZE SUPPORT B.
LENGTH VARIES WITH NUMBER OF CONDUITS TO BE SUPPORTED AND SPACING A.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-807
-E -8
.d g
617 704
E
C T
R
IC
A
12772252
A1
SCALE: NTS
C2
SCALE: NTS
A2
SCALE: NTS
A4
SCALE: NTS
U N
S U
P P
O R
T
M
IN
IM
U M
M A
X
IM
U M
V A
L U
E A
L L
O W
E D B
Y N
E C O
R
L E
N G
T H S
H A
L L N
O T E
X C
E E
D M
A X
IM
U M
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 6
NOTE 5
NOTES:
GENERAL NOTES:
DETAIL.
REQUIRED SHALL BE MADE IN ACCORDANCE WITH THIS
AND NO JUNCTION BOXES OR CONTROL DEVICES ARE
DEVICE WHERE A FLEXIBLE CONNECTION IS REQUIRED
INSTALLATION OF CONDUIT TO A MOTOR OR OTHER A.
L E
N G
T H A
S R
E Q
U
IR
E D
NOTE 4
NOTE 5
NOTE 6
NOTE 1
NOTE 7
NOTE 8
NOTE 9
NOTE 10
NOTE 11
NOTE 2
NOTE 3
USE WITH "FLOATING" SLAB OR DRILLED HOLE.11.
ELBOW10.
THREADED COUPLING9.
TABLES FOR MATERIAL REQUIREMENTS.
MINIMUM TWO 1/2" DIA CONCRETE ANCHORS, REFERENCE AREA CLASSIFICATION 8.
IF AL IS USED.
PROVIDE FELT SPACER OR BITUMASTIC COATING BETWEEN AL AND CONCRETE7.
SPACER6.
CONDUIT5.
FLEX TO EQUIPMENT 18" MINIMUM4.
CONDUIT CLAMP3.
SEALANT WHERE CONDUIT PASSES THROUGH SLAB.
PROVIDE A PVC SLEEVE AND FILL WITH ONE PART POLYURETHANE IMMERSIBLE 2.
GREATER THAN 2'-6" TALL, SIZE ANGLE SUPPORT PER SPECIFICATION 01 88 15.
SIZE ANGLE FOR CONDUIT, MINIMUM L 2 1/2 x 2 1/2 x 3/16,FOR ANY ANGLE 1.
NOTES:
GENERAL NOTES:
B.
C.
A.
END OF THE CONDUIT.
PROVIDE SUPPORT FOR ALL PVC CONDUIT WITHIN 3 INCHES OF THE
AN EQUIPMENT BASE, WALL, COLUMN, ETC, AS REQUIRED ABOVE.
ARE NOT OTHERWISE SUPPORTED IN A RIGID MANNER SUCH AS AGAINST
THIS DETAIL SHALL BE USED FOR SUPPORT OF ALL CONDUITS WHICH
OF THE CONDUIT.
THAN 18 INCHES OUT OF THE SLAB WITHIN 3 INCHES OF THE END
PROVIDE SUPPORT FOR ALL METAL CONDUITS WHICH EXTEND MORE
A3
SCALE: NTS
NOTE 1
NOTE 3
NOTE 4
NOTE 5
NOTE 2
NOTES:
RING WHERE APPLICABLE.
GROUND ROD, TIE INTO BUILDING GROUND5.
GROUND CONDUCTOR4.
METAL STAIR FRAMING3.
5/8" CAPSCREW, NUT, AND LOCKWASHER.
TERMINATE CONDUCTOR TO FLAT COMPRESSION,2.
HANDRAIL1.
M E
T E
R
O U
T S
ID
E
P L
U S (M
IN
O F C
O N
D U
IT
NOTE 1
NOTE 2
NOTE 3
NOTE 4
CONDUIT4.
INSULATION AS REQUIRED TO FILL CAVITY3.
PIPE SLEEVE OR CORE DRILLED HOLE IN CONCRETE WALL. 2.
METAL ESCUTCHEON, TYPICAL 1.
NOTES:
GENERAL NOTES:
BE INSTALLED IN ACCORDANCE WITH THIS DETAIL.
CONDUITS WHICH INDIVIDUALLY PASS THRU AN INTERIOR WALL SHALL A.
NOTE 1
NOTE 2
NOTE 3
NOTE 4
CATWALK CHANNEL FOR CONDUIT INSTALLATION.
CONDUIT SUPPORT CHANNEL PROVIDED AS PART OF4.
CONDUIT CLAMPS3.
CATWALK CHANNEL2.
CATWALK FLOOR1.
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
OVERSIZE SLEEVE 3.
ADJUSTABLE GLAND LOCATED WHERE ACCESSIBLE.2.
INSIDE OF STRUCTURE1.
NOTES:
GENERAL NOTES:
OF BUILDING EXTERIOR WALLS ARE BELOW GRADE.
USE WATERTIGHT CONDUIT SEAL WHERE CONDUIT PENETRATIONS A.
CONDUIT TO EQUIPMENT FROM CEILING CONDUIT TRANSITION AND SUPPORT
GENERAL STAIRWAY GROUNDING INTERIOR WALL PENETRATION CONDUIT RACKING SYSTEM WATERTIGHT WALL CONDUIT SEAL
"T" CONDULET 6.
CONDUIT (1" MINIMUM SIZE)5.
FLOOR4.
CLASSIFICATION TABLES FOR MATERIAL REQUIREMENTS.
FLOOR FLANGE AND A MINIMUM OF 4 CONCRETE ANCHORS 3/8" DIA MIN. REFERENCE AREA 3.
FLEX CONDUIT TO MOTOR OR OTHER DEVICE.2.
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA.
1. CONDUIT RACKING AND SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED
SPECIFIC DESIGN CRITERIA ON DRAWING G-008, STRUCTURAL GENERAL NOTES, AND LEGEND
SUPPORT, SIZE TOP AND ANY INTERMEDIATE LATERAL SUPPORTS AS REQUIRED BY SITE 1.
ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA.
SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL
STRUCTURAL GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING AND
REQUIRED BY SITE SPECIFIC DESIGN CRITERIA ON DRAWING G-008,
LOCATE AND SIZE SUPPORTS FOR VERTICAL AND LATERAL LOADS AS A.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-808
-E -8
.d g
618 704
E
C T
R
IC
A
12772253
C3
SCALE: NTS
A1
SCALE: NTS
A2
SCALE: NTS
A3
SCALE: NTS
SUSPENDED SLAB PENETRATION
A4
SCALE: NTS
REFERENCE AREA CLASSIFICATION TABLES FOR MATERIAL REQUIREMENTS.
POST BASE ATTACHED TO FLOOR WITH MINIMUM 1/2" DIA CONCRETE ANCHORS,9.
VERTICAL SUPPORT CHANNEL FRAMING.8.
CONDUIT RISER, TYPICAL. 7.
FOUR HOLE TEE PLATE, (TYPICAL EACH CROSS MEMBER).6.
MULTI-GRIP PIPE CLAMP, TYPICAL.5.
CROSS SUPPORT CHANNEL, LENGTH AS REQUIRED, TYPICAL.4.
CONNECTION TO ALLOW FOR 5/8" VERTICAL STRUCTURE DEFLECTION.3.
CONCRETE ANCHORS.
POST BASE ATTACHED TO UNDERSIDE OF STRUCTURE WITH MINIMUM 1/2" 2.
VALUES ALLOWED BY NEC.
LENGTH AS REQUIRED TO LIMIT UNSUPPORTED CONDUIT LENGTH TO MAXIMUM 1.
NOTES:
GENERAL NOTES:
N O
T E
N O
T E
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
NOTE 9
/4
GENERAL NOTES:
B.
A.
NOTE 4
NOTE 3
NOTE 2
NOTE 1
NOTE 5
NOTE 6
NOTE 7
NOTE 8
NOTE 10
NOTE 9 PROVIDE CONTINUOUS GROUND PATH PER NEC REQUIREMENTS.10.
CONDUIT, TYPICAL 9.
HUB8.
CLAMP, TYPICAL 7.
CLOSED CELL NEOPRENE6.
PREMOLDED JOINT FILLER5.
OR APPROVED EQUAL.
FLEXIBLE NEOPRENE SLEEVE CROUSE-HINDS "XD", APPLETON "DF"4.
ADAPTER REQUIRED FOR PVC CONDUITS.3.
CONDUIT, SIZE PER PLANS2.
OF GRS CONDUIT EACH SIDE OF FITTING.
PVC CONDUIT INSTALLATIONS SHALL HAVE 18 INCHES (MIN) LENGTH1.
CONCRETE ENCASED CONDUITS.
DETAIL APPLIES TO ALL EXPANSION JOINTS FOR THE UNDERGROUND
EXPANSION JOINTS.
DETAIL APPLIES TO CONDUIT EMBEDDED IN STRUCTURAL
EXPANSION JOINT
BONDING JUMPER STRAP
EXTERNAL TIN PLATED COPPER BRAID GROUNDING3.
CLAMP AND U-BOLT2.
CONDUIT 1.
GENERAL NOTES:
NOTES:
NOTE 2
NOTE 3
NOTE 1
JOINTS OR 100' INTERVALS.
COUPLINGS TO BE INSTALLED AT CONCRETE EXPANSION A.
JUMPER STRAP.
EXTERNAL TIN PLATED COPPER BRAID GROUNDING BONDING 6.
MOVEMENT.
WEATHERPROOF EXPANSION FITTING PROVIDE 4" CONDUIT5.
CLAMP AND U-BOLT4.
CONDUIT3.
ONE-PART POLYURETHANE IMMERSIBLE SEALANT.
USE CONDUIT SLEEVE WHERE CONCRETE OCCURS. FILL WITH A 2.
FINISH GRADE OR CONCRETE.1.
GENERAL NOTES:
NOTES:
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 3
NOTE 2
NOTE 1
AS SHOWN ON DRAWINGS.
OUTSIDE BUILDING AND CONNECTED TO BLDG EXTERIORS
USE THIS DETAIL FOR CONDUITS ROUTED FROM DUCT BANKS A.
STRUCTURAL SLAB3.
CONDUIT. FOR TYPE REQUIRED, SEE SPECIFICATIONS.2.
SLAB.
EXPANDABLE COMPOUND WHERE CONDUIT PASSES THROUGH
PROVIDE A PVC SLEEVE AND FILL WITH A SUITABLE PLASTIC 1.
GENERAL NOTES:
NOTES:
NOTE 1
NOTE 2
NOTE 3
WITH THIS DETAIL.
EQUIPMENT PADS SHALL BE INSTALLED IN ACCORDANCE
ALL CONDUITS THROUGH CONCRETE FLOOR SLABS AND A.
CONDUIT4.
COUPLING3.
PLUG2.
FINISHED FLOOR1.
GENERAL NOTES:
NOTES:
NOTE 1
NOTE 4
NOTE 2
NOTE 3
ACCORDANCE WITH THIS DETAIL.
FOR FUTURE EXTENSION SHALL BE INSTALLED IN
CONDUITS WHICH ARE STUBBED UP IN A CONCRETE SLAB A.
VERTICAL CONDUIT SUPPORT EXPANSION/DEFLECTION COUPLING
CONDUIT EXPANSION JOINT EXPANSION FITTING FOR SOIL MOVEMENT FLUSH CONDUIT STUB
PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA.
RACKING AND SUPPORT SYSTEM SHALL BE DESIGNED BY A QUALIFIED
DRAWING G-008, STRUCTURAL GENERAL NOTES, AND LEGEND 1. CONDUIT
AND LATERAL LOADS AS REQUIRED BY SITE SPECIFIC DESIGN CRITERIA ON
SIZE SUPPORT POST, CROSS CHANNELS, AND CONNECTIONS FOR VERTICAL A.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-809
-E -8
.d g
619 704
E
C T
R
IC
A
12772254
A1
SCALE: NTS
C3
SCALE: NTS
A4
SCALE: NTS
3"
3"
3" CLR, (TYPICAL BOT).5.
2" CLR, (TYPICAL TOP AND SIDES).4.
#4 LONGITUDINAL BARS @18" OC MAXIMUM, WITH 2'-0" LAP.3.
#4@18" OC, TYPICAL2.
WHERE INDICATED ON DUCT BANK SCHEDULE.
#4/0 COPPER GROUND CONDUCTOR, TYPICAL. PROVIDE ONLY 1.
M
IN
IM
U M
MINIMUM
4"
MINIMUM
4"
M
IN
IM
U M
MINIMUM
4"
MINIMUM
4"
M
IN
IM
U M
M
IN
IM
U
M MINIMUM
4"
MINIMUM
4"
M
IN
IM
U M
M
IN
IM
U M
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
3" 3"
3" 3"
MINIMUM
4"
MINIMUM
4"
MINIMUM
4"
M
IN
IM
U M
M
IN
IM
U M
M
IN
IM
U M
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
UP TO 2'-0"
ELEVATION
DETAIL A DETAIL B
WITH SPECIFICATIONS AND CLASSIFICATION TABLES.
ALL CONTRACTOR FURNISHED METALS SHALL BE IN ACCORDANCEB.
MP-HUSKY TYPE PS-2622S SWIVEL JOINT CLAMP.
FOR APPLICATIONS REQUIRING A SWIVEL JOINT USE AA.
3" MINIMUM
2" MAXIMUM
6'-0" MAXIMUM
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3 NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 8
NOTE 9
NOTE 10
NOTE 11
NOTE 12
NOTE 13
D = 2"MIN FOR <2 INCH CONDUIT
D = 3"MIN FOR 2"-6" CONDUIT
PLASTIC, MAGNETIC 3" WIDE.7.
SPACERS6.
#12 GALV IRON TIE DOWN WIRE, MAXIMUM 4'-0" APART.5.
FINISH GRADE4.
COMPACTED EARTH BACKFILL.3.
ABOVE AND 3" BELOW CONDUITS, HAND TAMP.
BACKFILL WITH BEDDING AND PIPE ZONE MATERIAL 3" 2.
2'-0" MINIMUM (< 600 VOLTS) 3'-0 MINIMUM (> 600 VOLTS)1.
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
AND POWER CONDUIT (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 6" CONCRETE OR 18" OF WELLD.
AND POWER CONDUITS (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 4" CONCRETE OR 12" OF WELL C.
WHERE INDICATED ON DUCT BANK SCHEDULE.
#4/0 GROUND CONDUCTOR, TYPICAL, PROVIDE ONLY B.
IN ACCORDANCE WITH THIS DETAIL.
INCLUDE THREE OR MORE CONDUITS SHALL BE MADE
INSTALLATION OF DIRECT BURIAL DUCT BANKS WHICH A.
DUCT BANK DUCT BANK
CONDUIT SUPPORT FROM STEEL BEAM TYPICAL UNDERGROUND CONDUIT
#4 @ 18" CTRS, VERT LEGS 1'-6" MINIMUM. 4.
REBAR, CONDUIT SEPARATION AND CONCRETE COVER.
FOR LARGER DUCT BANKS, CONTINUE PATTERN OF3.
#4 @ 18" CTRS, VERT LEGS 1'-0" MINIMUM. 2.
ONLY WHERE INDICATED ON DUCT BANK SCHEDULE.
#4/0 COPPER GROUND CONDUCTOR, TYPICAL, PROVIDE1.
AND POWER CONDUIT (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 6" CONCRETE OR 18" OF WELLD.
AND POWER CONDUITS (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 4" CONCRETE OR 12" OF WELL C.
SIDE OF ROADWAY.
UNDER ROADWAYS PLUS 2 FEET ON EITHER
REBAR REINFORCEMENT REQUIRED ONLYB.
DUCT RUNS.
3/4" MINUS, UNDER ALL CONCRETE ENCASED
PROVIDE 6" MINIMUM COMPACTED GRAVEL,A.
AND POWER CONDUIT (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 6" CONCRETE OR 18" OF WELLE.
AND POWER CONDUITS (? 600V)
COMPACTED EARTH BETWEEN TELECOM CONDUITS
MAINTAIN MINIMUM OF 4" CONCRETE OR 12" OF WELL D.
FOR LARGER DUCT BANKS, SEE C3/E-809C.
PLUS 2 FEET ON EITHER SIDE OF ROADWAY.
REBAR REINFORCEMENT REQUIRED ONLY UNDER ROADWAYS B.
ALL CONCRETE ENCASED DUCT RUNS.
PROVIDE 6" MINIMUM COMPACTED GRAVEL, 3/4" MINUS, UNDER A.
TO ROOF OR FLOOR DECK/SLAB ABOVE UNLESS BRACED TO WALL.
ENGINEER REGISTERED IN THE STATE OF NORTH CAROLINA. BRACE
SYSTEM SHALL BE DESIGNED BY A QUALIFIED PROFESSIONAL
GENERAL NOTES, AND LEGEND 1. CONDUIT RACKING AND SUPPORT
SITE SPECIFIC DESIGN CRITERIA ON DRAWING G-008, STRUCTURAL
SIZE SUPPORT RODS, CONNECTIONS AND BRACES AS REQUIRED BY
DETERMINE SPAN AND TYPE OF SUPPORTS, LOCATE SUPPORTS, AND
Z-PURLING MALLEABLE ELECTRO-GALVANIZED C-CLAMP, OR EQUAL. 13.
FRAMING CHANNEL, WELD IN PLACE.12.
COLUMN11.
1/2" DIA MINIMUM CONCRETE ANCHOR, TYPICAL. 10.
PLATE, 1/4" THK x 6" SQ9.
WELD8.
SEE DETAIL A OR B 7.
FRAMING CHANNEL, TYPICAL 6.
ELEVATIONS VARY, SEE PLANS. 5.
FRAMING CHANNEL 4.
NUT AND PLATE WASHER, TYPICAL. 3.
ALL THREADED 1/2" DIA MINIMUM ROD UNISTRUT, UNIROD OR EQUAL.2.
SUPPORT STEEL 1.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-810
-E -8
.d g
620 704
E
C T
R
IC
A
12772255
SITE PULL BOX
A1
SCALE: NTS
TRENCH AND CONDUIT PLACEMENT
C3
SCALE: NTS
A3
SCALE: NTS
HANDHOLE REQUIREMENTS
CRUSHED ROCK7.
BOX AND COVER6.
COMPACTED EARTH 5.
SECTIONAL BOX WHEN REQUIRED.4.
SKID RESISTENT SURFACE. 3.
PULL SLOT2.
STAINLESS STEEL HEX BOLT AND WASHER.1.
NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 6
NOTE 5
NOTE 7
LA
BEL
OPTIC CABLE INSTALLATION.
ELECTRICAL CIRCUITS. "FIBER OPTIC" FOR FIBER
PROVIDE LABEL "ELECTRICAL" ON COVER FOR C.
PROVIDE WITH (2) 2 1/2" MOUSEHOLES.B.
PROVIDE STAINLESS STEEL BOLTS AND INSERTS.C.
10" x 10" AREA.
LOAD OF NO LESS THAN 15,000 LBS OVER A
COVER AND BOX SHALL WITHSTAND A SERVICE B.
OF NO LESS THAN 10,000 psi.
REINFORCING WITH COMPRESSIVE STRENGTH
REINFORCED WITH A HEAVY WEAVE FIBERGLASS
HOUSING SHALL BE A POLYMER CONCRETE A. V
A
R
IE
S A
S
2'-6" MINIMUM
MINIMUM
1'-0" MINIMUM
1'-0"
M
IN
IM
U M
M
IN
IM
U M
MINIMUM
6"
D E
P T
H V
A R
IE
S
WIDTH VARIES
NOTES:
N U
M B
E R O
F D
U C
T S
R E
Q U
IR
E D P
E R
SECTION
NOTE 7
NOTE 8
NOTE 9
NOTE 10
NOTE 11
NOTE 12
NOTE 13
NOTE 1
NOTE 2
NOTE 4
NOTE 5
NOTE 6
NOTE 14
N O
T E
C1, E-810
A1, E-810
CONDUIT6.
COMPACTED BEDDING AND PIPE ZONE MATERIAL.5.
PLASTIC, MAGNETIC 3" WIDE DETECTABLE TAPE.4.
COMPACTED EARTH BACKFILL.3.
SEE TRENCH AC TOPPING DETAIL (IF APPLICABLE).2.
FINISH GRADE1.
M
IN
IM
U M
V
O L T S
M
IN
IM
U M
V
O L T S
(1-DUCT)
8" MINIMUM
(2-DUCTS)
1'-2" MINIMUM
M
IN
IM
M
IN
IM
2" 2"
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
THIS DETAIL.
TWO OR LESS CONDUITS SHALL BE MADE IN ACCORDANCE WITH
INSTALLATION OF DIRECT BURIED DUCT BANKS WHICH INCLUDE A.
GENERAL NOTES:
3"
PLAN
G G
G
GG
G
G
G
WIDTH VARIES
W
ID
T H V
A R
IE
S
3'-0" MINIMUM
C3
99-E-510
C3
99-E-510
NOTES:
NOTES 1 & 2
NOTES 8
NOTES 7
NOTES 6
NOTES 5
NOTES 4
NOTES 3
N O
T E
S
GROUND CONDUCTOR8.
DUCT BANK 7.
GROUND CONDUCTOR6.
GROUND ROD5.
DUCT BANK 4.
"TELECOMMUNICATIONS"
FOR FIBER DATA, AND TELEPHONE CIRCUITS. SEE MANHOLE SCHEDULE, INSCRIBE3.
LESS POWER CIRCUITS.
INSCRIBE "ELECTRICAL LOW VOLTAGE" IF ALL CIRCUITS IN MANHOLE ARE 600V OR 2.
INSCRIBE "ELECTRICAL HIGH VOLTAGE" IF ANY CIRCUIT IN MANHOLE IS ABOVE 600V.1.
MANHOLE (MH) AND HANDHOLE (HH) - WITH GROUNDING
MANHOLE (MH) AND HANDHOLE (HH) - WITH GROUNDING
ON THE DRAWINGS.
SIZE MANHOLES AS PER NEC REQUIREMENTS UNLESS OTHERWISE NOTED14.
GROUND ROD, WHERE REQUIRED. 13.
8" MIN DRAIN WITH GRATE.12.
8 PULLING IRONS, 2 EACH CORNER (TOP AND BOTTOM).11.
TYPICAL.
GROUT TO FULL WALL THICKNESS AROUND PIPES AT KNOCKOUTS,10.
4 LIFTING INSERTS9.
FINISH GRADE8.
COVER WITH LOCKING BOLTS & SEALING RING.7.
10 CF 1" TO 1 1/2" GRAVEL, ALL AROUND DRAIN.6.
COMPACTED GRAVEL, 12" DEEP MINIMUM, 3/4" MINUS.5.
#4/0 GROUND CONDUCTOR, WHERE REQUIRED4.
CABLE RACK GROUND WHERE REQUIRED, TYPICAL. 3.
"C" CHANNEL INSERTS 3 EACH FACE FOR CABLE RACKS.2.
GRADING RINGS AS REQUIRED.1.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-811
-E -8
.d g
621 704
E
C T
R
IC
A
12772256
A1
SCALE: NTS
C2
SCALE: NTS
A2
SCALE: NTS
C4
SCALE: NTS
CABLE RACK CONDUIT MANHOLE ENTRANCE CONDUIT MANHOLE ENTRANCE
SIZE AS REQUIRED.
CABLE RACK, HOOKS AND INSULATORS, NUMBER AND1.
NOTES:
NOTE 1
B L
O C
K O
U T A
S R
E Q
U
IR
E D
INSIDE OF MANHOLE OR BUILDING. 2.
CONCRETE ENCASED DUCT BANK.1.
NOTES:
NOTE 1
NOTE 2
KNOCKOUTS, TYPICAL.
GROUT TO FULL WALL THICKNESS AROUND PIPES AT 5.
CONDUIT4.
OUTSIDE FACE OF MANHOLE WALL. 3.
END BELL2.
INSIDE FACE OF MANHOLE WALL. 1.
NOTES:
NOTE 2
NOTE 1 NOTE 3
NOTE 4
NOTE 5
PANELBOARD NAMEPLATE OSHA/NEC PLACARD
PANEL TYPE BACKGROUND LETTERING
208/120 VOLT, 60 HZ
480 VOLT, 60 HZ
EMERGENCY SERVICES
WHITE
RED
WHITE
BLACK
BLACK
WHITE
COLOR SCHEDULE
FROM BREAKER XXX
480V, 3 PHASE 3 WIRE, 60 HZ
1/4 "4 1/2 " 1/4 "
/8
/8
59PNL01
MOTOR CONTROL CENTER 59MCC01
1/8 " SPACING BETWEEN OTHER ROWS
1/4 " SPACING BETWEEN FIRST 2 ROWS
OTHER ROWS:
TOP ROW:
NOTE 1
NOTE 2
1/8 " LETTERS
3/8 " LETTERS
REQUIRED DATA
1/8" HOLE FOR POP RIVET, (2 PLACES).2.
BEVELED EDGES 1.
XXX = BASED ON FINAL DESIGN SHOP DRAWING
THIRD AND FOURTH LINES:
SECOND LINE:
FIRST LINE:
POWER SOURCE AND BREAKER
PHASE, VOLTAGE, FREQUENCY
PANEL DESIGNATION
AREA IN FRONT OF THIS
ELECTRICAL PANEL MUST BE
KEPT CLEAR FOR 42 INCHES
OSHA-NEC REGULATIONS
10"
/2
1/8" HOLE FOR POP RIVET, (2 PLACES). 1.
1/2 " LETTERS
3/4 " LETTERS
NOTES:
NOTE 1
BLACK LETTERING ON YELLOW BACKGROUND
BOTTOM ROW:
TOP 3 ROWS:
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-812
-E -8
.d g
622 704
E
C T
R
IC
A
12772257
C2
SCALE: NTS
C4
SCALE: NTS
A1
SCALE: NTS
BOTTOM OF TRAY
1.5 MIN
CONNECTION
BEAM SUPPORT
AS SHOWN ON DRAWINGS
WIDTH OF TRAY (WOT)
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
NOTE 1
NOTE 8
3" 1"
NOTES:
HOLD DOWN CLIP8.
MINIMUM 1 5/8" CHANNEL SUPPORT.7.
CABLE TRAY6.
MINIMUM 3/8" ROD THREADED EA END.5.
TO STRUCTURE ABOVE4.
TURNBUCKLE3.
HANGER ROD2.
SPECIFICATION 01 88 15. BRACE TO ROOF OR FLOOR DECK/SLAB ABOVE UNLESS BRACED TO WALL.
SUPPORTS, LOCATE SUPPORTS, AND SIZE SUPPORT RODS, CONNECTIONS AND BRACES PER
Z-PURLING MALLEABLE ELECTRO-GALVANIZED C-CLAMP, OR EQUAL. DETERMINE SPAN AND TYPE OF1.
TURNBUCKLE
CABLE TRAY SUPPORT
AND HAVE NO SHARP CORNERS.
FASTENING HARDWARE IN TRAY SHALL BE ROUNDED A.
UNLESS OTHERWISE INDICATED.
2/0 BARE COPPER STRANDED GROUND CONDUCTOR 7.
CABLE TRAY 6.
THROAT, SIZE AS REQUIRED.
INSULATING GROUNDING BUSHING WITH INSULATED5.
PARALLEL CLAMP, SIZE AS REQUIRED.4.
OZ TYPE CTC OR EQUAL CABLE TRAY CLAMP.3.
CONDUIT DROP, SIZE AS NOTED. 2.
GROUND CONDUCTOR, SIZE AS REQUIRED.1.
NOTES:
GENERAL NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
CONDUIT DROP INTO CABLE TRAY CABLE TRAY PENETRATION
CLASSIFICATION TABLES FOR MATERIAL REQUIREMENTS.
1/4" DIA THROUGH BOLTS, REFERENCE AREA 4.
WALL FRAME CABLE TRAY FITTING. 3.
CONCRETE OR MASONRY WALL.2.
CONTINUOUS CABLE TRAY THROUGH WALL.1.
NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
KBS-SEALBAGS OR EQUAL.
SEAL OPENING IN AND AROUND CABLE TRAY WITH A.
GENERAL NOTES:
SLAB
BACKFILL
D
NOTES:
NOTE 1
NOTE 2
NOTE 3
LOWEST ELEVATION.
OF RACEWAYS SHALL BE INSTALLED IN THE BACKFILL ZONE, AND ONLY AT THE
ZONE. SPACE RACEWAYS PER "D", THIS DETAIL. NO MORE THAN TWO LAYERS
SINGLE LAYER ABOVE RACEWAYS IN THE LOWEST ELEVATION OF THE BACKFILL
3. RACEWAYS THAT CROSS WITHIN THE BACKFILL ZONE SHALL BE INSTALLED AS A
AT THE LOWEST ELEVATION OF THE BACKFILL ZONE WITH SPACING AS NOTED.
2. INDIVIDUAL RACEWAYS OR A SINGLE LAYER OF RACEWAYS SHALL BE INSTALLED
THE BACKFILL ZONE, AS SPECIFIED IN SECTION 31 23 00.00.20.
OF RACEWAYS UNDER A SLAB ON GRADE SHALL BE INSTALLED IN A TRENCH BELOW
SIMILAR TO STANDARD DETAIL A4/99-E-509. THE PLACEMENT OF MULTIPLE LAYERS1.
D = 2"MIN FOR <2 INCH CONDUIT
D = 3"MIN FOR 2"-6" CONDUIT
RACEWAYS INSTALLED UNDER SLABS
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-813
-E -8
.d g
623 704
E
C T
R
IC
A
12772258
A1
SCALE: NTS
DUCTBANK ROUTED UNDER FOOTING
C4
SCALE: NTS
A4
SCALE: NTS
S E
E S
IT
E P
L A
N S
F O
R C
O N
T
IN
U A
T
IO
N
NOTES:
NOTE 1
NOTE 4
NOTE 6
NOTE 5
NOTE 3
NOTE 2
INTERIOR EXTERIOR
AND LOCATIONS, PER SPECIFICATION 05 50 13.
ANCHOR BOLTS WITH NUTS. INSTALL NUMBER, SIZE, 4.
EQUIPMENT PAD TYPE "F", SEE STRUCTURAL DETAILS.3.
OSHA/NEC PLACARD2.
MANUFACTURER'S NAMEPLATE(S)1.
NOTES:
NOTE 1
NOTE 2
NOTE 3
NOTE 4
6"
CLR (ABOVE)
TRANSFORMER
1/4" PLATE
SIDE
SUPPORT PLATE
IN CENTER TO
DOUBLE CHANNEL
TYP
1 5/8" X 3 1/4"
DOUBLE CHANNEL
BASE, TYP
CHANNEL POST
NOTES:
EACH END
PLATE FITTING,
CHANNEL FLAT
WALL
CONCRETE WALL
TO NON-STRUCTURAL/NON-
WHEN LOCATED ADJACENT
PROVIDE REAR SUPPORT
PANELBOARD
M
IN
45°
M
IN
NOTES:
S E
E S
IT
E P
L A
N
F O
R C
O N
T
IN
U A
T
IO
N
NOTE 3
NOTE 2
NOTE 4
NOTE 6
NOTE 5
NOTE 1
NOTE 7
INTERIOR EXTERIOR
DUCTBANK ROUTING THROUGH STEM WALL TRANSFORMER
STACKED TRANSFORMER MOUNTING INSTALLATION
SEE C5, E-814.3.
MAINTAIN PROPER NEC CLEARANCES FOR PANELBOARDS. 2.
SPECIFICATIONS.
FOR MATERIAL TYPE REQUIREMENTS AND AREA CLASSIFICATIONS, SEE1.
CONCRETE ENCASED DUCTBANK. 6.
BUILDING FOOTING5.
BUILDING STEM WALL 4.
UNDER SLAB CONDUIT, A1/E-8123.
FLOOR SLAB2.
SPACE WITH EXPANDABLE FOAM.
ALL CONDUIT AND EDGES OF BLOCKOUT. FILL ALL
THERE IS A MINIMUM OF 1.5" OF SPACE BETWEEN
BLOCKOUT IN STEM WALL, BLOCKOUT SIZED SO 1.
DUCTBANK7.
1" VOID FORM6.
UNDER SLAB CONDUITS, A1/E-8125.
BUILDING FOOTING4.
FLOOR SLAB3.
TO ELECTRICAL EQUIPMENT MOUNTED AGAINST EXTERIOR WALL.
PROVIDE SLEEVES AS REQUIRED FOR CONDUIT INSTALLATION FROM DUCTBANKS 2.
ALL SIDES OF DUCTBANK.
CONTROLLED LOW STRENGTH FILL. PROVIDE A MINIMUM OF 12" OF FILL ON
BACKFILL ENTIRE DEPTH OF DUCTBANK EXCAVATION BELOW FOOTING WITH1.
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-814
-E -8
.d g
624 704
E
C T
R
IC
A
12772259
A1
A3
SCALE: NTS
C5
(ABOVE)
TRANSFORMER
FRONT
3.
2.
1.
(BELOW)
PANELBOARD
NOTES:
M
IN
26 05 02.
AREA CLASSIFICATIONS, SEE SPECIFICATION
FOR MATERIAL TYPE REQUIREMENTS AND
CONCRETE ANCHORS, SEE SPECIFICATIONS.
ALL NUTS AND BOLTS.
USE WASHERS, SPLIT-LOCK WASHERS UNDER
FITTING, TYP
WING SHAPED
STEEL CHANNEL
30", MIN
FINISHED GRADE
14' ABOVE
FINISHED GRADE
4' ABOVE
NOTE 2NOTE 1
NOTE 3
NOTE 4
NOTE 7
NOTE 8
NOTE 5
NOTE 6
NOTE 4
WITH DRAIN LOOP
WATERTIGHT FLEX
CAMERA JUNCTION BOX TO SECURITY PANEL.
MINIMUM 1" CONDUIT FROM REMOTE 8.
ENCLOSURE STRAPPED TO POLE.7.
BOX AND CAMERA MOUNT.
FLEX CONDUIT - MOUNT BETWEEN BACK 6.
BOX.
SURFACE MOUNT SINGLE GANG JUNCTION 5.
TO REMOTE CAMERA JUNCTION BOX.
MINIMUM 1" CONDUIT FROM JUNCTION BOX 4.
FIXED CAMERA IN ENCLOSURE. 3.
POLE MOUNT ADAPTER AND WALL MOUNT. 2.
FIXTURE AT TOP.
REINFORCED CAMERA POLE, WITH LIGHT 1.
NOTES
PLAN
ELEVATION
6"
1/4"
TYPICAL
TYP
1/2"
1/4"
GENERAL NOTES:
NOTE 3
NOTE 4
NOTE 5
NOTE 6
NOTE 7
BOLTS.
B. ATTACH BRACKET TO WALKWAY BEAM WITH 4 3/4" DIA A325N
A. GALVANIZE ENTIRE ASSEMBLY AFTER FABRICATION.
3/8" STIFFENER PLATE7.
1/2" PLATE, 12" x 12"6.
LIGHTING POLE5.
1/2" PLATE, 12" x 12"4.
MINIMUM EMBED.
5/8" DIA SST EXPANSION ANCHOR, 4-INCH3.
STIFFENERS BELOW2.
TOP OF CONCRETE1.
NOTES:
3 1/2"
NOTE 1
NOTE 2
LIGHTING POLE MOUNT TO SIDE OF CONCRETE WALL FIXED CAMERA IN ENCLOSURE - POLE MOUNT
TRANSFORMER MOUNTING
SEE T-630
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
R E
N O
R F
O L
K
V
IR
G
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
C
IL
IT
G
IN
E E
R
S
T E
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R
J E
U N
E J
A C
K S
O N
V
IL
L E
N
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
STATE OF
No 60201
R E
E
NI
G
NE LANOI
S S
E F
O R
P
ADIROL
F
ESNECIL
N O
SL
OHCIN .C DI
V
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
T A
IL
S
E-815
-E -8
.d g
625 704
E
C T
R
IC
A
12772260
DIRECT/INDIRECT LED TROFFER
REVISED: APRIL 2016 NL-1LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, WITH ONE-PIECE LOWER REFLECTOR
HAVING TEXTURED, HIGH REFLECTANCE, WHITE POLYESTER POWDER-COATED FINISH.
OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND 2FT x 4FT AVAILABLE.
2. LIGHT SOURCE - UPWARD-FACING LEDS WITH DIFFUSE LENS TO ELIMINATE DIRECT VIEW
OF LIGHT SOURCE. 3500K COLOR TEMPERATURE UON, MAXIMUM BINNING TOLERANCE OF
A 4-STEP MCADAM ELLIPSE, MINIMUM EFFICACY OF 90 LUMENS/WATT, WITH A MINIMUM
CRI OF 80. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE
SCHEDULE.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO INDICATE A
CERTAIN MANUFACTURER OR PREFERENCE.
PRISMATIC LENS LED TROFFER
REVISED: APRIL 2016 NL-3LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD ROLLED STEEL, PAINTED AFTER FABRICATION. EXTRUDED
ALUMINUM DOOR WITH SPRING-LOADED CAM LATCHES. HIGH REFLECTANCE, WHITE
POLYESTER POWDER-COATED FINISH. OPTIONAL SIZES OF 1FT x 4FT, 2FT x 2FT, AND
2FT x 4FT AVAILABLE.
2. LIGHT SOURCE - LED BOARD OR ARRAY WITH MINIMUM 50K HOURS RATED LIFE AT L70,
3500K COLOR TEMPERATURE UON, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, MINIMUM EFFICACY OF 90 LUMENS/WATT, WITH A
MINIMUM CRI OF 80. INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED IN LUMINAIRE
SCHEDULE.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
6. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
LED INDUSTRIAL STRIP
REVISED: APRIL 2016 NL-7LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY
AND SPECULAR ALUMINUM OR HIGHLY-REFLECTIVE PAINTED STEEL REFLECTORS.
OPTIONAL LENGTHS OF 4FT OR 8FT.
2. FINISH - MULTI-STAGE PHOSPHATE BONDING TREATMENT FINISHED WITH
HIGH-REFLECTANCE, WHITE POLYESTER POWDER COAT, PAINTED AFTER FABRICATION.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
3500K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 100 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE ON CEILING OR SUSPENDED.
7. OPTIONS - WIRE GUARD, CHAIN, STEM OR SWIVEL STEM HANGERS.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
WALL MOUNTED LED
REVISED: APRIL 2016 NL-9LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-FORMED, COLD-ROLLED STEEL, WITH REINFORCEMENT RIBS FOR RIGIDITY;
END CAPS SAME MATERIAL AS HOUSING, SECURED WITH TABS, SCREWS OR RIVETS. WHITE
ENAMEL FINISH APPLIED AFTER FABRICATION. OPTIONAL LENGTHS OF 2FT OR 4FT.
2. LENS - ACRYLIC PRISMATIC OR WHITE OPAL TO PROVIDE EVEN ILLUMINATION AND TO
ELIMINATE PIXILATION FROM LED LIGHT SOURCE.
3. LIGHT SOURCE - SOLID STATE LEDS WITH MINIMUM 50K HOURS RATED LIFE AT L70,
3500K CCT UON, MINIMUM 80 CRI, MAXIMUM 4-STEP MCADAM ELLIPSE BINNING
TOLERANCE FOR COLOR CONSISTENCY, AND MINIMUM EFFICACY OF 90 LUMENS/WATT.
INITIAL LUMEN OUTPUT AS INDICATED IN LUMINAIRE SCHEDULE.
4. DRIVER - REPLACEABLE, INTEGRAL, HIGH-EFFICIENCY DRIVER WITH MINIMUM 0.9 PF,
OPERATING VOLTAGE OF 120-277V, THERMAL MANAGEMENT, < 20% TOTAL HARMONIC
DISTORTION. ON-OFF CONTROL, STEP-DIMMABLE OR FULLY DIMMABLE AS INDICATED.
5. CERTIFICATION - UL 1598, DAMP LOCATION, DLC QUALIFIED, AND ROHS COMPLIANT.
COMPLIES WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED
WITH EMERGENCY BATTERY BACK-UP.
6. MOUNTING - SURFACE.
7. OPTIONS - INTEGRAL MOTION SENSOR, EMERGENCY BACK-UP.
8. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE THAT
LED ENCLOSED AND GASKETED
REVISED: APRIL 2016 NL-11LIGHTING PLATE:
LUMINAIRE REQUIREMENTS:
1. HOUSING - FIBERGLASS OR FIBERGLASS-REINFORCED POLYESTER OUTER HOUSING, WITH
ALUMINUM COMPONENT TRAY AND HEAT SINK. OPTIONAL LENGTHS OF 4FT OR 8FT.
2. LENS - IMPACT-RESISTANT ACRYLIC OR OPTIONAL POLYCARBONATE, WITH CONTINUOUS
CLOSED-CELL POLYURETHANE GASKET, SECURED WITH STAINLESS STEEL OR
POLYCARBONATE LATCHES.
3. LIGHT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .