P1043 Amend 0002_Drawings_Arch.pdf
PDF 364 KB Posted
- Solicitation number
- N4008521R0052
About this file
This document includes architectural drawings and specifications for a federal construction contract opportunity. The project constructs an 8 million gallon per day water treatment facility utilizing membrane filtration technology to better enable compliance with current and future regulatory requirements and address potential saltwater intrusion into water supply aquifers. The facility will provide adequate and environmentally compliant potable water to meet domestic, industrial, and fire protection needs at Marine Corps Base Camp Lejeune. Specific documents include architectural floor plans for a Concentrate Clarifier building showing layouts of pump rooms, electrical rooms, and chemical rooms.
View the file
Other files
Show 40 more
Latest 50 of 71 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N A
V A
L F
A C
IL
IT
IE
S E
N G
IN
E E
R
IN
G S
T S
T E
M S C
O M
M A
N D
M
ID
L A
T
D C
O
R E
N O
R F
O L
K
V
IR
G
IN
IA
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
D E
P A
R T
M E
F
H
E
V Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N A
V
L
F
C
IL
IT
IE
S
G
IN
E E
R
G
Y S
T E
M
M M
A N
D
DES DRW
S Y
M D
E S
C R
IP
T
IO
N D
A T E
A P
P R
DRAWFORM REVISION: 31 JANUARY 2017
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
H
D
N O
T P
O
IN
T W
A T
E R T
R E
A T
M E
N T P
L A
N T R
E P
L A
C E
M E
N T
M A
R
R P
B
M P
J E
U N
E J
A C
K S
O N
V
IL
L E
N
796455
License Number F-0699 Tel: 919-875-4311
Suite 214 Raleigh, NC 27604 3120 Highwoods Blvd, 04/22/2021
DSN
Sophia Schwartz, via email
TD BJN
A-191
F
IL
E N
A M
E
P L
O T D
A T
E
P L
O T T
IM
E
P
L O
T D
A T
E P
L O
T T
IM
E P -A -1
.d g n
A R
C H
IT
E C
T U
R A
3/16" = 1'-0"
8'0 4' 16'
F L
O O
R P
L A
N
FLOOR PLAN
C O
N C
E N
T R
A T
E C
L A
R
IF
IE
R B
U
IL
D
IN
G
BT68'-0"
12'-8"
PUMP ROOM
2'-8"6'-0"10'-0"10'-0"11'-4"6'-0"22'-0"
3'-4" 4'-8"
90-101
90-102 90-103
ROOM
ELECTRICAL
ROOM
CHEMICAL
90-101A
90-102B
90-103B
-1
A
90-103C
-1
A
A-291
A-291
GENERAL SHEET NOTES
SHEET KEYNOTES
2 3
ALUMINUM LOUVER 90-LV-19.
SIDEWALK, SEE CIVIL DRAWINGS8.
DOWNSPOUT WITH GRATED TRENCH IN SIDEWALK7.
DOWNSPOUT WITH PRECAST CONCRETE SPLASHBLOCK6.
EQUIPMENT PADS, TYPICAL5.
8" INTERIOR CMU WALL4.
RIGID INSULATION R-10 MIN3.
4" VENEER2.
8" EXTERIOR CMU WALL1.
9 9
A1
A
A1
A
A1
A
A1
A
B
B
A1
A-291
A3
B1
A-291
C1
M.O.
M .O
M.O. M.O. M.O.
3/16"=1'-0
A2
A-391
A2
A-391
SEE LIFE SAFETY PLAN A-090 FOR FIRE EXTINGUISHERS.8.
LOUVERS.
SEE DRAWING A-602 FOR DOORS, FRAMES, HARDWARE AND 7.
SEE DRAWING G-023 FOR WALL TYPES.6.
PLAN.
SEE ELEVATIONS FOR LOCATIONS OF ELEMENTS NOT SEEN IN 5.
ELEVATIONS FOR VENEER CONTROL JOINTS.
SEE STRUCTURAL FOR CMU CONTROL JOINTS. SEE 4.
SUPPLEMENT INTERIOR SIGN SCHEDULE.
SIGN SCHEDULE AND 10 14 00.20 WITH
SPECIFICATIONS 10 14 00.10 WITH SUPPLEMENT EXTERIOR
FOR INTERIOR AND EXTERIOR BUILDING SIGNAGE, SEE 3.
AND GENERAL ARCHITECTURAL NOTES.
SEE DRAWING G-011 FOR GENERAL ARCHITECTURAL LEGEND 2.
CONSTRUCTED DIMENSIONS.
EACH JAMB. FIELD VERIFY OPENINGS FOR ACTUAL
ARE NOMINAL. PROVIDE AN ADDITIONAL 3/8" SHIM SPACE
"M.O." REFERS TO MASONRY OPENINGS. DIMENSIONS SHOWN 1.
546 704
12772181
EJA
DJD
GFS
1-HR
-H
R
N A
V F
A C R
E V
IE
W R
E V
IS
IO
N S
/2
/2
T D
AR 15126
ADIR
OLF FO ETATS
T C
E
TI
H
CRA DERE
T
SI
G E
R
E G
D
OD .M YHT
O
MI
A-191 - ARCHITECTURAL FLOOR PLAN CONCENTRATE CLARIFIER BUILDING
| 2021-05-21T09:49:07-0400 | |
| Timothy Dodge |
File details come from the government source that posted it. Updated .