Amendment 0007 03JUL2024.pdf
PDF 781 KB Posted
- Attached to
- DBB for Correct Shoreline Erosion at USCG Station Siuslaw in Florence, OR (NMACC III Pool 1)
- Solicitation number
- 70Z05024R43000003
About this file
This document is Amendment 0007 to Solicitation 70Z05024R43000003 for a Design/Bid/Build construction project to correct shoreline erosion at the U.S. Coast Guard Station Siuslaw River in Florence, Oregon. The amendment provides revisions to the attachments, specifications, drawings, and key notes. Key changes include: replacing a specification section, removing and inserting new key notes related to maintaining utilities during the 3-week bridgeway disruption, and providing additional details on the PZC sheet piling material properties. The proposal due date is not extended. Offerors are required to acknowledge receipt of this amendment in their proposal response. This opportunity is only available to the successful NMACC III Pool 1 offerors.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE
PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
1. CONTRACT ID CODE
2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)
7. ADMINISTERED BY (If other than Item 6) CODE
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA FAR (48 CFR) 53.243
FACILITY CODE
9A. AMENDMENT OF SOLICITATION
NO.
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NO.
10B. DATED (SEE ITEM 13)
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.
12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.
IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15C. DATE SIGNED
15A. NAME AND TITLE OF SIGNER (Type or print)
16C. DATE SIGNED
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PAGE OF PAGES
6. ISSUED BY CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)
CODE
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
NSN 7540-01-152-8070
Previous edition unusable
70Z05024R43000003; CORRECT SHORELINE EROSION AT USCG STATION SIUSLAW, FLORENCE, OR
The purpose of this amendment is to provide Attachment, and Specification/Drawing revisions.
USCG FDCC SEATTLE
915 SECOND AVE, RM 2664
SEATTLE, WASHINGTON 98174-1011
70Z05024R43000003
1 2
07/03/2024
05/29/2024
70Z05024R43000003
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
ENCLOSED DOCUMENT:
A. REVISIONS TO THE TASK ORDER ANNOUNCEMENT/AMENDMENT ATTACHMENTS
Please find attached to this Amendment for PPI 084 answered via Amendment 0006.
B. REVISIONS TO THE SPECIFICATIONS/DRAWINGS/AMENDMENTS
1. Amendment 0006 Item 8
REMOVE
Section 31 14 16 – 3.8
REPLACE WITH
Section 31 41 16 – 3.8
2. Amendment 0006 Item 14
REMOVE
Key Notes 15, 19, and 20
INSERT:
"New" Key Note 15: Contractor is responsible for maintaining all utilities down to the floating dock/covered mooring during work. Utilities may be disrupted for the same 3 weeks as the bridgeway disruption. At the end of the three-week disruptions utilities must be reestablished.
INSERT
"New" Key Note 21: Contractor is responsible for maintaining all utilities down to the floating dock/covered mooring during work. Utilities may be disrupted for the same 3 weeks as the bridgeway disruption. At the end of the three-week disruption utilities must be reestablished.
All other terms and conditions remain unchanged. The Proposal due date IS NOT EXTENDED.
Offerors are reminded to acknowledge receipt of this amendment in response to the subject TOA.
www.sheet-piling.com www.gerdau.com
PZC profiles are named for their strength in metric designations. For example, PZC 18 has a Section Modulus of 1,800 cm3/meter. Make PZC sheet piling your first choice for its unmatched combination of drivability, ruggedness, and strength to weight efficiency. Standard production in ASTM A572 Grade 60 with corrosion resistant steels (A690 and A588) available upon request. Inquire for higher strength steel availability.
PZC SHEET PILING PROPERTIES
*Both sides of sheet; excludes socket interior and ball of interlock. All dimensions given are nominal. Actual flange and web thicknesses vary due to mill rolling practices;
however, permitted variations for such dimensions are not addressed.
27.88"
17.7"
0.60"
0.60"
0.525"
15.2 mm
13.3 mm
708 mm
450 mm
15.2 mm
PZC 26
51˚54˚
25" 635 mm
0.375
9.5 mm
0.375"
9.5 mm
12.56" 319 mm
27.88" 708 mm
0.375"
9.5 mm
0.375
9.5 mm
"0.375"
9.5 mm
PZC 13
42˚ 15.25 387 mm
0.375"
9.5 mm
PZC 18
PZC 19
PZC 18
PZC 17
PZC 13
PZC 28
PZC 26
PZC 25
Per Unit of Wall
Section
Nominal Width
Wall Depth
(Height)
Web Thickness
Flange Thickness in.
(mm) in.
(mm) in.
(mm) in.
(mm)
Cross Sectional
Area
Weight Cross Sectional
Area
WeightMoment of Inertia
Moment of Inertia
Elastic Section Modulus
Plastic Section Modulus
Total Surface
Area
Nominal Coating Area* in.2 (cm2) in.2/ft (cm2/m) lbs/ft (kg/m) lbs/ft2 (kg/m2) in.4 (cm4) in.4/ft (cm4/m) in.3 (cm3) ft2/ft (m2/m) in.3/ft (cm3/m)
Elastic Section Modulus in.3/ft (cm3/m) ft2/ft (m2/m)
Per Single Section Plastic Section Modulus in.3 (cm3)
PZC 14
PZC 12
25.00 15.30 0.420 0.420 16.16 55.0 576.3 75.3 89.14 6.10 5.60 7.75 26.4 276.6 36.1 42.79
635 388 10.7 10.7 104.2 81.8 23,990 1,235 1,461 1.86 1.71 164.1 128.8 37,780 1,945 2,301
25.00 15.25 0.375 0.375 14.82 50.4 532.2 69.8 82.20 6.10 5.60 7.12 24.2 255.5 33.5 39.46
635 387 9.5 9.5 95.6 75.1 22,150 1,145 1,347 1.86 1.71 150.6 118.2 34,890 1,800 2,121
25.00 15.21 0.335 0.335 13.64 46.4 491.8 64.6 76.04 6.10 5.60 6.55 22.3 236.1 31.0 36.50
635 386 8.5 8.5 88.0 69.1 20,470 1,060 1,246 1.86 1.71 138.6 108.8 32,235 1,670 1,962
27.88 12.56 0.375 0.375 14.82 50.4 353.0 56.2 66.93 6.10 5.60 6.38 21.7 152.0 24.2 28.81
708 319 9.5 9.5 95.6 75.1 14,690 920 1,097 1.86 1.71 135.1 106.0 20,760 1,300 1,549
27.88 17.75 0.570 0.645 23.22 79.0 1,057 119.1 143.07 6.65 6.15 10.00 34.0 455.1 51.3 61.58
708 451 14.5 16.4 149.8 117.6 44,000 1,950 2,344 2.03 1.87 211.6 166.1 62,150 2,755 3,311
27.88 17.70 0.525 0.600 21.72 73.9 994.3 112.4 134.46 6.65 6.15 9.35 31.8 428.1 48.4 57.89
708 450 13.3 15.2 140.1 110.0 41,390 1,840 2,203 2.03 1.87 197.9 155.4 58,460 2,600 3,112
27.88 17.66 0.485 0.560 20.40 69.4 938.7 106.3 126.77 6.65 6.15 8.78 29.9 404.1 45.7 54.56
708 449 12.3 14.2 131.6 103.3 39,070 1,740 2,077 2.03 1.87 185.9 145.9 55,190 2,455 2,933
27.88 12.60 0.420 0.420 16.15 55.0 381.6 60.5 72.61 6.10 5.60 6.95 23.7 164.3 26.0 31.25
708 320 10.7 10.7 104.2 81.8 15,890 1,190 990 1.86 1.71 147.2 115.5 22,440 1,400 1,680
27.88 12.52 0.335 0.335 13.64 46.4 324.5 51.8 61.51 6.10 5.60 5.87 20.0 139.7 22.3 26.47
708 318 8.5 8.5 88.0 69.1 13,510 850 1,008 1.86 1.71 124.3 97.6 19,080 1,200 1,423 corinne.williams Rectangle corinne.williams Callout corinne.williams Text Box Proposed substitute to Nucor NZ28 corinne.williams Rectangle
File details come from the government source that posted it. Updated .