2.8.1(a) Consolidation Q&A-Question 16 Reference.pdf

PDF 354 KB Posted

Attached to
FEMA Region 2 Naval Weapons Station Earle Building C-54 Comprehensive Facility Upgrades
Solicitation number
70FBR226R00000016
Issued by

About this file

This is a product pricing document from the Compose Price List (April 2026) for electrical components, specifically detailing the Base Feed Module with hardwire connection options.

The document presents pricing for three product configurations: 3-Circuit Hardwire 20 Amp and two 4-Circuit variants (2+2 and 3+1 configurations). Each configuration is available in five feed lengths: 48 inches ($572.79–$632.79), 72 inches ($639.79–$699.79), 120 inches ($773.79–$833.79), 180 inches ($941.29–$1,001.29), and 300 inches ($1,276.29–$1,336.29). The 3-Circuit module includes eight 12-gauge wires supporting up to three 20-amp circuits, while the 4-Circuit modules include six 12-gauge and two 10-gauge wires for up to four 20-amp circuits. All modules feature a black 0.5-inch flexible galvanized steel conduit in charcoal trim color only and are designed for 120-volt 60-hertz power sources only. Key application restrictions include use only with floor, column, or wall hardwire connections on powered base raceways of panel frames, exclusion from tile-to-floor panel applications, and requirement for local authority having jurisdiction approval before installation. The base feed module can be field-modified for left- or right-hand conditions.

View the file

Other files

File Type Posted
2.4.1(b) Attachment B-NWSE Building C-54 A100 Floor Plan.pdf PDF
2.4.1(i) Attachment I-RRCC Wall and Doors Picture 5.pdf PDF
2.4.1(n) Attachment N-Technical Evaluation Factors-Consolidation Requirement_08.03.2026.pdf PDF
2.4.1(c) Attachment C-Specs for Doors for Earle_07.28.26_OR.pdf PDF
2.4.1(f) Attachment F-RRCC Wall and Doors picture 2.pdf PDF
2.4.1(j) Attachment J-RRCC Wall and Doors Picture 6.pdf PDF
2.4.1(g) Attachment G-RRCC Wall and Doors Picture 3.pdf PDF
2.4.1(p) Attachment P-CLIN Pricing Excel Sheet.pdf PDF
2.8.1 Consolidation Project NWSE Questions 09.09.26_v3.pdf PDF
2.4.1(e) Attachment E-RRCC Wall and Doors Picture 1.pdf PDF
2.4.1(d) Attachment D-RRCC Scale Diagram.pdf PDF
2.4.1(k) Attachment K-RRCC Wall and Doors Picture 7.pdf PDF
2.4.1(p) Attachment P-CLIN Pricing Excel Sheet.xlsx XLSX spreadsheet
2.4.1(o) Attachment O-Wage Determination Davis Bacon No. NJ20260037 Mod 1 05.18.26.pdf PDF
2.4.1(l) Attachment L-Training Room Planar_VideoWall 8x4 DLP 1.2 2K Nit.pdf PDF
2.4.1(m) Attachment M-Notice to Offerors-Statement of Contractor Assurance.pdf PDF
2.4.1(h) Attachment H-RRCC Wall and Doors Picture 4.pdf PDF
2.4.1(a) Attachment A-SOW_CONSOLIDATED-Doors_RRCC_Wall_Concrete_ v8_09.09.2026 Security Edits.pdf PDF
2.4.1 Solicitation 70FBR226R00000016_001.pdf PDF
2.4.1 Solicitation 70FBR226R00000016_001.pdf PDF
2.4.1(g) Attachment G-CLIN Pricing Excel Sheet.pdf PDF
2.4.1(e) Attachment E-Technical Evaluation Factors-Consolidation Requirement_08.03.2026.pdf PDF
2.4.1(c) Attachment C-Specs for Doors for Earle_07.28.26_OR.pdf PDF
2.4.1(g) Attachment G-CLIN Pricing Excel Sheet.xlsx XLSX spreadsheet
2.4.1(d) Attachment D-Notice to Offerors-Statement of Contractor Assurance.pdf PDF
2.4.1(f) Attachment F-Wage Determination Davis Bacon No. NJ20260037 Mod 1 05.18.26.pdf PDF
2.4.1(b) Attachment B-NWSE Building C-54 A100 Floor Plan.pdf PDF
2.4.1(a) Attachment A-SOW_CONSOLIDATED-Roof Doors RRCC_Concrete_ v6_08.21.2026 Security Edits.pdf PDF
2.4.1 Solicitation 70FBR226R00000016_001.pdf PDF
2.4.1(f) Attachment F-Wage Determination Davis Bacon No. NJ20260037 Mod 1 05.18.26.pdf PDF
2.4.1(g) Attachment G-CLIN Pricing Excel Sheet.pdf PDF
2.4.1 Solicitation 70FBR226R00000016_001.pdf PDF
2.4.1(c) Attachment C-Specs for Doors for Earle_07.28.26_OR.pdf PDF
2.4.1(e) Attachment E-Technical Evaluation Factors-Consolidation Requirement_08.03.2026.pdf PDF
2.4.1(g) Attachment G-CLIN Pricing Excel Sheet.xlsx XLSX spreadsheet
2.4.1(a) Attachment A-SOW_CONSOLIDATED-Roof Doors RRCC_Concrete_ v6_08.21.2026 Security Edits.pdf PDF
2.4.1(b) Attachment B-NWSE Building C-54 A100 Floor Plan.pdf PDF
2.4.1(d) Attachment D-Notice to Offerors-Statement of Contractor Assurance.pdf PDF
2.2.1(d) Attachment D-Notice to Offerors-Statement of Contractor Assurance.pdf PDF
2.2.1(g) Attachment G-CLIN Pricing Excel Sheet.xlsx XLSX spreadsheet
2.2.1(e) Attachment E-Technical Evaluation Factors-Consolidation Requirement_08.03.2026.pdf PDF
2.2.1(b) Attachment B-NWSE Building C-54 A100 Floor Plan.pdf PDF
2.2.1(g) Attachment G-CLIN Pricing Excel Sheet.pdf PDF
2.2.1(a) Attachment A-SOW_CONSOLIDATED-Roof Doors RRCC_Concrete_ v4_08.04.2026 Security Edits.pdf PDF
2.2.1 Solicitation 70FBR226R00000016.pdf PDF
2.2.1(f) Attachment F-Wage Determination Davis Bacon No. NJ20260037 Mod 1 05.18.26.pdf PDF
2.2.1(c) Attachment C-Specs for Doors for Earle_07.28.26_OR.pdf PDF
Show all 47

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Feed Module

— Hardwire Connection — 3- or 4-Circuit

VZEB-0000-3

VZEB-0000-H2

VZEB-0000-H4

Class BC

Features

• Includes one base feed with black 0.5”(13mm) flexible galvanized steel conduit.

• Conduit for 3-Circuit includes eight 12-gauge wires for up to three 20 amp circuits of power.

• Conduit for 4-Circuit includes six 12-gauge and two 10-gauge wires for up to four 20 amp circuits of power.

• Base feed module can be field modified to accommodate left- or right-hand conditions.

• Standard in charcoal trim color only.

Specification Tips

• For use with:

–120 volt 60 hertz power sources only.

–Floor, column or wall hardwire connections –Frames equipped with power components

• Attaches at any one of the four receptacle sites in a powered base raceway of a panel frame.

• Not for use with tile to the floor panel applications.

• Do not mix components from different wiring configurations. Unique polarity keys and colors are used for each wiring configuration.

• Application may require approval of local authority having jurisdiction

(AHJ); ensure compliance before placing orders and installation.

To Order, Specify:

1) Product number.

(No finish specification required.)

Description Feed Length Number Price 3-Circuit

3-Circuit Hardwire 20 Amp 48”(1219mm) VZEB-0000-3 $ 572.79

72”(1829mm) VZEB-0006-H3 639.79

120”(3048mm) VZEB-0010-H3 773.79

180”(4572mm) VZEB-0015-H3 941.29

300”(7620mm) VZEB-0025-H3 1276.29

4-Circuit, 2+2

4-Circuit, 2+2 Hardwire 20 Amp 48”(1219mm) VZEB-0000-H2 $ 632.79

72”(1829mm) VZEB-0006-H2 699.79

120”(3048mm) VZEB-0010-H2 833.79

180”(4572mm) VZEB-0015-H2 1001.29

300”(7620mm) VZEB-0025-H2 1336.29

4-Circuit, 3+1

4-Circuit, 3+1 Hardwire 20 Amp 48”(1219mm) VZEB-0000-H4 $ 632.79

72”(1829mm) VZEB-0006-H4 699.79

120”(3048mm) VZEB-0010-H4 833.79

180”(4572mm) VZEB-0015-H4 1001.29

300”(7620mm) VZEB-0025-H4 1336.29