About this file

This solicitation is for an Indefinite Delivery Indefinite Quantity Multiple Award Task Order Contract to provide construction services for federal facilities in Eastern Washington, Eastern Oregon, and Idaho. GSA intends to award six contracts under this vehicle, which has a total maximum value of $70 million over five years. Task orders will range from $25,000 to $5 million, with most between $50,000 and $250,000. Services include tenant improvements, building envelope repairs, conveyance and mechanical/electrical/plumbing system work, roofing, and exterior improvements using delivery methods such as design-bid-build, design-build, and bridging design-build. A pre-proposal conference for a seed project will be held on July 6, 2022. The NAICS code is 236220 for commercial and institutional building construction, with a small business size standard of $39.5 million.

View the file

Other files for this federal contract opportunity

Other files attached to Eastern Multiple Award Task Order Contract (MATOC) Replacement, newest first.
File Type Posted
Amend 0007 Attachment F Seed Project Price and Services Schedule Rev2.xlsx XLSX spreadsheet
Amend 0007 SF30 47PL0122R0035.pdf PDF
Amend 0007 Contractor RFIs and Responses.pdf PDF
Amend 0006 Attachment F Seed Project Price and Services Schedule Rev1.xlsx XLSX spreadsheet
Amend 0006 Contractor RFIs and Responses.pdf PDF
Amend 0006 SF30 47PL0122R0035.pdf PDF
Amend 0006 Attachment F Seed Project Price and Services Schedule Rev1.xlsx XLSX spreadsheet
Amend 0005 SF30 47PL0122R0035.pdf PDF
Amend 0005 Contractor RFIs and Responses 4.pdf PDF
Amend 0004 SF30 47PL0122R0035.pdf PDF
Amend 0004 Site Visit Sign In Sheet 2 Redacted.pdf PDF
Amend 0003 2019 Asbestos Reinspection Survey Report Thomas S Foley USCH.pdf PDF
Amend 0003 SF30 47PL0122R0035.pdf PDF
Amend 0003 Contractor RFI_s and Responses 2.pdf PDF
Amend 0002 Contractor RFIs and Responses.pdf PDF
Amend 0002 SF30 47PL0122R0035.pdf PDF
Amend 0002 Exhibit 6 Past Performance Questionnaire Rev1.docx DOCX document
Amend 0002 R10 EMATOC SOW 04222022.pdf PDF
Amend 0002 Site Visit Sign In Sheet Redacted.pdf PDF
Amend 0001 SF1442 47PL0122R0035.pdf PDF
Amend 0001 RFP EMATOC 47PL0122R0035.pdf PDF
Amend 0001 SF30 47PL0122R0035.pdf PDF
Amend 0001 Attachment D - TORFP Seed Project.pdf PDF
Attachment C Example of TO Reps and Certs.docx DOCX document
Exhibit 2 Read Me First - CUI Document.pdf PDF
7.5 Submittal Transmittal Form.xls XLS spreadsheet
7.11 Project Management Information System.pdf PDF
SF1442 47PL0122R0035 EMATOC.pdf PDF
Attachment A EMATOC Terms and Conditions.pdf PDF
Attachment D TORFP Seed Project.pdf PDF
Attachment E Seed Project SOW.pdf PDF
Attachment F Seed Project Price and Services Schedule.xlsx XLSX spreadsheet
7.1 Vendor Security Training.pdf PDF
7.4 Sample OF 306.pdf PDF
RFP EMATOC 47PL0122R0035.pdf PDF
EMATOC Agreement.pdf PDF
Attachment B Example of TO Agreement.docx DOCX document
Exhibit 1 3490.3 Policy.pdf PDF
Exhibit 4 Contractor Project Experience Form.docx DOCX document
Exhibit 5 Key Personnel Resume Form.docx DOCX document
Exhibit 8 IDIQ Price Schedule.xlsx XLSX spreadsheet
SF1442 47PL0122R0041 Seed Project.pdf PDF
7.6 Controlled Unclassified Information 34903.pdf PDF
GSA527-21.pdf PDF
Attachment G Seed Project Wage Determination.pdf PDF
Exhibit 3 GSAAffiliatedCustomerAccounts.pdf PDF
Exhibit 6 Past Performance Questionnaire.docx DOCX document
Exhibit 7 GSA Security Manual.pdf PDF
7.2 Sample ROCAL.xlsx XLSX spreadsheet
7.3 Sample CIW Form 850.docx DOCX document
Show all 50

Eastern Multiple Award Task Order Contract (MATOC) Replacement has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTRUCTIONS

TABSINSTRUCTIONS
SAMPLE EQUIP ImpExp TempThis tab is an exmple for creating new assets
Equip Removed TemplateThis tab can be used for removing old assets. Old assets will have a ASSETNUM colum because the asset number is autogenerated.
Equip Installed TemplateThis tab can be used for creating new assets. New assets will not have a ASSETNUM colum because the asset number is autogenerated. When using the import tool in Maximo, the object structure GSAASSETIMPEXP must be selected
Equipment / Asset TypeThis tab is an exmple for creating new assets
Manufacturers ListList of equipment manufacturers
FIELDDESCRIPTIONRequired?
EQUIP TAGThis is the original Equipment or Asset ID coming from the originating system. This will be used as reference to the old system going forward.
EQUIP TYPEThis is the predefined type of this asset - must come from the AssetType tab in this spreadsheet.ALWAYS
DESCRIPTIONThis describes the assetALWAYS, EXCEPT WHEN ADDING A CLASSIFICATION
ASSET.DESCRIPTION_LONGDESCRIPTIONThis is the long description for the asset
LEGACY LOCATIONThis is the GSA legacy location, can be typed in text describing where to find the asset.ALWAYS
MAKEThis is the makeALWAYS
MANUFACTURER YEARThis is the manufacturer yearALWAYS
MODEL NO.This is the manufacturer's model name or model number for the assetALWAYS
QUANTITYThis is the quantityALWAYS
INSTALL DATEThis is the installation date. CCYY-MM-DDTHH:mm:ss.ffALWAYS
LOCATIONThis is the Maximo location code of the asset and MUST be the code from the NCMMS. Please let the data team know if you need an export by building of valid location codes.ALWAYS
MANUFACTURERThis is the manufacturer code of the asset and must come from the Manufacturers tab in this spreadsheet.ALWAYS
ASSET.PARENTThis is the parent asset number the asset field is for the Maximo asset identifier, the value Maximo uses to track the asset. This field can only be filled in if the Parent Asset exists in the NCMMS.
ASSET.PRIORITYThis is the asset priority - copied to work order when entered.
BUILDING NAME & ADDRESSThis identifies a service address. It must be unique by site for each service address and MUST be 8 characters.ALWAYS
SERIAL NUMThis is the asset serial numberALWAYS
ASSET.GSACAPITALIZEDThis field is used for ESPC assets (Yes or No). Spreadsheet should have a '1' in the field for Yes.
ASSET.VENDORThis field is used for ESPC assets that are maintained by the ESCO. This selection must be from the Company application. Leave blank if the O&M maintains the asset.
ADDITIONAL REQUIRED DATADESCRIPTIONRequired?
WARRANTY INFORMAIONProvide all warranty information and datesALWAYS
IOEM AND USER MANUALSProvide all IOEM and User Manuals for all equipment installedALWAYS
EQUIPMENT AND DATAPLATE PICTURESProvide pictures of all newly installed equpment and dataplatesALWAYS
PREVENTATIVE MAINTENANCE SCHEDULESProvide Preventative Maintenance schedules for all newly installed equipment.ALWAYS

SAMPLE Equip ImpExp Temp

ASSET NUMEQUIP TAGEQUIP TYPEDESCRIPTIONDESCRIPTION_LONGDESCRIPTIONLEGACY LOCATIONMANUFACTURER YEARMANUFACTURERMAKEMODEL NO.SERIAL NUMQUANTITYINSTALL DATEBUILDING NAME & ADDRESSLOCATIONPARENTPRIORITYGSACAPITALIZEDVENDORWARRANTYMANUALSEQUIPMENT PICTURESPM SCHEDULES
ASSET.EQUIP TAGASSET.EQUIP TYPEASSET.DESCRIPTIONASSET.DESCRIPTION_LONGDESCRIPTIONASSET.LEGACY LOCATIONASSET.MANUFACTURER YEARASSET.MANUFACTURERASSET.MAKEASSET.MODEL NO.ASSET.SERIAL NUMASSET.QUANTITYASSET.INSTALL DATEASSET.BUILDING NAME & ADDRESSASSET.LOCATIONASSET.PARENTASSET.PRIORITYASSET.GSACAPITALIZEDASSET.VENDOR
Should be loaded with New-1, New-2 etc to add new assets.This is the original Equipment or Asset ID coming from the originating system. This will be used as reference to the old system going forward.This is the predefined type of this equipment - must come from the Equipment / AssetType tab in this spreadsheet.This describes the equipmentThis is the GSA legacy location, can be typed in text describing where to find the asset. Example: Floor, Room, NW Corner of RoofThis is the manufacturer yearThis is the installation date. CCYY-MM-DDTHH:mm:ss.ffThis is the manufacturer code of the asset and must come from the Manufacturers tab in this spreadsheet.This is the makeThis identifies a service address. It must be unique by site for each service address and MUST be 8 characters.This is the manufacturer's model name or model number for the equipmentThis is the asset serial numberThis is the quantityThis is the building name and address.This field is used for ESPC assets (Yes or No). Spreadsheet should have a '1' in the field for Yes.This field is used for ESPC assets that are maintained by the ESCO. This selection must be from the Company application. Leave blank if the O&M maintains the asset.Was warranty information provided for listed equipment?Were all IOEM and User Manuals provided for listed equipment?Include pictures of equipment and the equipment's nameplate data for upload. Were pictures of all equipent and nameplates provided?Include all Preventative Maintenance schedules for new equipment. Was the PM schedules provided for the listed equipment?
New-1AC-4A/BDPPDamper, PoweredDamper, Powered4th Floor Mechanical Room2014RUSKINCD50869811Jan 1 2015FL0079ZZ469791YesYesYesYes
New-2AC-5A/BDPPDamper, PoweredDamper, Powered5th Floor Mechanical Room2014RUSKINCD50869901Jan 1 2015FL0079ZZ469961YesYesYesYes
New-3AC-6A/BDPPDamper, PoweredDamper, Powered6th Floor Mechanical Room2014RUSKINCD50870001Jan 1 2015FL0079ZZ470101YesYesYesYes
New-4AC-7A/BDPPDamper, PoweredDamper, Powered7th Floor Mechanical Room2014RUSKINCD50869721Jan 1 2015FL0079ZZ470281YesYesYesYes
New-5AC-8ADPPDamper, PoweredDamper, Powered8th Floor Mechanical Room2014RUSKINCD50869821Jan 1 2015FL0079ZZ470421YesYesYesYes
New-6AC-9A/BDPPDamper, PoweredDamper, Powered9th Floor Mechanical Room2014RUSKINCD50869871Jan 1 2015FL0079ZZ470531YesYesYesYes
New-7AC-4ARTUPackage Unit, Water CooledPackage Unit, Water Cooled4th Floor, Room 2242014DAIKINSWP033HLS1Jan 1 2015FL0079ZZ469791YesYesYesYes
New-8AC-4BRTUPackage Unit, Water CooledPackage Unit, Water Cooled4th Floor, Room 2252014DAIKINSWP033HLS1Jan 1 2015FL0079ZZ469791YesYesYesYes
New-9AC-5ARTUPackage Unit, Water CooledPackage Unit, Water Cooled5th Floor Mechanical Room2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ469961YesYesYesYes
New-10AC-5BRTUPackage Unit, Water CooledPackage Unit, Water Cooled5th Floor Mechanical Room2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ469961YesYesYesYes
New-11AC-6ARTUPackage Unit, Water CooledPackage Unit, Water CooledRoof, NW Corner2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ470101YesYesYesYes
New-12AC-6BRTUPackage Unit, Water CooledPackage Unit, Water CooledRoof, SW Corner2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ470101YesYesYesYes
New-13AC-7ARTUPackage Unit, Water CooledPackage Unit, Water Cooled7th Floor Mechanical Room2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ470281YesYesYesYes
New-14AC-7BRTUPackage Unit, Water CooledPackage Unit, Water Cooled7th Floor Mechanical Room2014DAIKINSWP023HLS1Jan 1 2015FL0079ZZ470281YesYesYesYes
New-15AC-8BRTUPackage Unit, Water CooledPackage Unit, Water Cooled8th Floor Mechanical Room2014DAIKINSWP028HLS1Jan 1 2015FL0079ZZ470421YesYesYesYes
New-16AC-9ARTUPackage Unit, Water CooledPackage Unit, Water Cooled9th Floor Mechanical Room2014DAIKINSWP033HLS1Jan 1 2015FL0079ZZ470531YesYesYesYes
New-17AC-9BRTUPackage Unit, Water CooledPackage Unit, Water Cooled9th Floor Mechanical Room2014DAIKINSWP033HLS1Jan 1 2015FL0079ZZ470531YesYesYesYes
New-18ERV-1ERVEnergy Recovery VentilatorEnergy Recovery Ventilator9th Floor Mechanical Room2014MultistackCONSERVE C500S1Jan 2 2015FL0079ZZ470531YesYesYesYes

Equip Removed Template

ASSET NUMEQUIP TAGEQUIP TYPEDESCRIPTIONDESCRIPTION_LONGDESCRIPTIONLEGACY LOCATIONMANUFACTURER YEARMANUFACTURERMAKEMODEL NO.SERIAL NUMQUANTITYINSTALL DATELOCATIONPARENTPRIORITYBUILDING NAME & ADDRESSGSACAPITALIZEDVENDOR
ASSET.EQUIP TAGASSET.EQUIP TYPEASSET.DESCRIPTIONASSET.DESCRIPTION_LONGDESCRIPTIONASSET.LEGACY LOCATIONASSET.MANUFACTURER YEARASSET.MANUFACTURERASSET.MAKEASSET.MODEL NO.ASSET.SERIAL NUMASSET.QUANTITYASSET.INSTALL DATEASSET.LOCATIONASSET.PARENTASSET.PRIORITYASSET.BUILDING NAME & ADDRESSASSET.GSACAPITALIZEDASSET.VENDOR
This is the original Equipment or Asset ID coming from the originating system. This will be used as reference to the old system going forward.This is the predefined type of this asset - must come from the AssetType tab in this spreadsheet.This describes the assetThis is the GSA legacy location, can be typed in text describing where to find the asset.This is the manufacturer yearThis is the manufacturer code of the asset and must come from the Manufacturers tab in this spreadsheet.This is the make of the equipmentThis is the manufacturer's model name or model number for the assetThis is the asset serial numberThis is the quantityThis is the installation date. CCYY-MM-DDTHH:mm:ss.ffThis is the Maximo location code of the asset and MUST be the code from the NCMMS. Please let the data team know if you need an export by building of valid location codes.This identifies a service address. It must be unique by site for each service address and MUST be 8 characters.
Removed-1
Removed-2
Removed-3
Removed-4
Removed-5

Equip Installed Template

ASSET NUMEQUIP TAGEQUIP TYPEDESCRIPTIONDESCRIPTION_LONGDESCRIPTIONLEGACY LOCATIONMANUFACTURER YEARMANUFACTURERMAKEMODEL NO.SERIAL NUMQUANTITYINSTALL DATELOCATIONPARENTPRIORITYBUILDING NAME & ADDRESSGSACAPITALIZEDVENDORWARRANTYMANUALSEQUIPMENT PICTURESPM SCHEDULES
ASSET.EQUIP TAGASSET.EQUIP TYPEASSET.DESCRIPTIONASSET.DESCRIPTION_LONGDESCRIPTIONASSET.LEGACY LOCATIONASSET.MANUFACTURER YEARASSET.MANUFACTURERASSET.MAKEASSET.MODEL NO.ASSET.SERIAL NUMASSET.QUANTITYASSET.INSTALL DATEASSET.LOCATIONASSET.PARENTASSET.PRIORITYASSET.BUILDING NAME & ADDRESSASSET.GSACAPITALIZEDASSET.VENDOR
This is the original Equipment or Asset ID coming from the originating system. This will be used as reference to the old system going forward.This is the predefined type of this equipment - must come from the Equipment / AssetType tab in this spreadsheet.This describes the equipmentThis is the GSA legacy location, can be typed in text describing where to find the asset. Example: Floor, Room, NW Corner of RoofThis is the manufacturer yearThis is the manufacturer code of the asset and must come from the Manufacturers tab in this spreadsheet.This is the makeThis is the manufacturer's model name or model number for the equipmentThis is the asset serial numberThis is the quantityThis is the installation date. CCYY-MM-DDTHH:mm:ss.ffThis is the building name and address.This identifies a service address. It must be unique by site for each service address and MUST be 8 characters.This field is used for ESPC assets (Yes or No). Spreadsheet should have a '1' in the field for Yes.This field is used for ESPC assets that are maintained by the ESCO. This selection must be from the Company application. Leave blank if the O&M maintains the asset.Was warranty information provided for listed equipment?Were all IOEM and User Manuals provided for listed equipment?Include pictures of equipment and the equipment's nameplate data for upload. Were pictures of all equipent and nameplates provided?Include all Preventative Maintenance schedules for new equipment. Was the PM schedules provided for the listed equipment?
New-1
New-2
New-3
New-4
New-1
New-2
New-3
New-4
New-5
New-6
New-7
New-8
New-9
New-10
New-11
New-12
New-13
New-14
New-15
New-16
New-17
New-18

Equipment AssetType

ASSETTypeAsset Type DescriptionGSA_Class1993 JobPlan1995 JobPlan2008 JobPlan2012 JobPlanRUN TO FAILUniformat_DescriptionUniformat_IICSI_MF_2004Omniclass_Table_21Omniclass_Table_23RSM_PM_CodeCriticality_
ClassificationQAEstimated_Cost*Unit_Of_MeasureFACTS
ABLAir BlowerD30 HVAC (MF2004 DIV. 23 - HVAC)D304022 15 0021-04 30 50 5023-33 31 13G3025 534 19503P$1,804.00EAD304007.04.03
ACCCondenser, Air-CooledC-24C-24-1-1993C-24-A-1995HVAC-CND-01-01M-2008
HVAC-CND-01-01Y-2008HVAC-CND-01-01M-2012
HVAC-CND-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 63 1321-04 30 30 9023-33 43 11D3035 210 19503P$12,725.00EAD303001.04.XX.XX.XX
ACR-01Computer Room Air-Conditioning Unit, Package: or Special SystemsC-4HVAC-ACR-01-01MD30 HVAC (MF2004 DIV. 23 - HVAC)D3050
ACR-02Heat Pumps, Water Cooled (WSHP)A-10HVAC-ACR-02-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 17 11 13EAD303001.03.02
ACR-03Air Conditioning Unit or Heat Pump Split System,A-5A-5-A-1995HVAC-ACR-03-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 17 13 11D303001.03.02
ACR-04Air Conditioning Unit, Ceiling/Wall/Window MountedA-13HVAC-ACR-04-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303022-23 76 00 or 22-23 80 0023-33 39 11 11EAD305006.01, D305006.02
ACR-05Air-Cooled CondenserA-9HVAC-ACR-05-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303022-23 76 0023-33 43 11EAD303001.04.02, D303001.04.02.01, D303001.04.02.01.01, D303001.04.02.01.02, D303001.04.02.02, D303001.04.02.02.01, 303001.04.02.02.02, D303001.04.02.02.03
ACR-06Evaporative CondenserC-11HVAC-ACR-06-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 43 13EAD303001.04.03, D303001.04.03.01, D303001.04.03.01.01, D303001.04.03.01.02, D303001.04.03.02, D303001.04.03.02.01, D303001.04.03.02.02
ACTAir CurtainA-2A-02-6-1993A-2-A-1995RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D304023 34 3321-04 30 30 9023-33 31 114$1,127.00EAD304007.04.02
ACUAir Conditioner PackageA-6, A-7A-06-1-1993A-7-M-1995 A-6-A-1995HVAC-AHU-05-01Y-2008 HVAC-AHU-04-01Y-2008HVAC-AHU-05-01Y-2012 HVAC-AHU-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D305023 81 1321-04 30 30 9023-33 39 17D3055 250 19503P$23,868.75EAD305006.XX.XX.XX
ACWAir Conditioner, WindowA-8A-08-1-1993A-8-A-1995HVAC-ACR-04-01Y-2008HVAC-ACR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D305023 81 1621-04 30 30 9023-33 39 19 15D3055 250 19504$1,127.00EAD305006.02.03.XX
ADOAudio SystemN/AF-16B-A-1995FLSF-ALM-13-01Y-2008FLSF-ALM-13-01Y-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E102027 41 0021-04 60 30 1023-37 15 29D5030 910 02203$21,110.29EAE102009.07
ADRAir DryerA-1A-01-6-1993A-1-S-1995HVAC-AIR-01-06M-2008HVAC-AIR-01-06M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304022 15 0021-04 20 60 1023-33 47 00D3095 118 19503P$1,804.00EAD304008.01.XX
AERAeratorD20 Plumbing (MF2004 DIV. 22 - Plumbing)D201022 15 0021-04 20 10 6023-31 11 00G3025 534 19503P$2,151.00EAD201003.XX.XX.XX.XX.XX
AGS-01Tanks, Air, Refrigerant, LP GasT-2TANK-AGS-01-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D301022-23 13 0023-27 29 00EA, GALF104002.03.01 Above Ground F104002.03.02 Below Ground
AHU-01Air Handling Unit, 3 ton thru 24 tonA-11A-11-1-1993A-11-A-1995HVAC-AHU-01-01Y-2008HVAC-AHU-01-01Y-2012
HVAC-AHU-03-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 72 1321-04 30 6023-33 25 00D3045 110 19502P$17,100.00EAD304008.XX.XX.XX
AHU-02Air Handling Unit, 25 ton thru 50 tonA-11A-11-1-1993A-11-A-1995HVAC-AHU-01-01Y-2008HVAC-AHU-03-01Y-2012

HVAC-AHU-01-01Y-2012

HVAC-AHU-01-02M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 72 1321-04 30 6023-33 25 00D3045 110 29502P$60,133.33EAD304008.03.01.02
AHU-03Air Handling Unit, over 50 tonA-11A-11-1-1993A-11-A-1995HVAC-AHU-01-01Y-2008HVAC-AHU-03-01Y-2012

HVAC-AHU-01-02M-2012

HVAC-AHU-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 72 1321-04 30 6023-33 25 00D3045 110 39502P$82,000.00EAD304008.03.XX.XX
AHU-04Air Handling Unit, Computer RoomA-11A-11-1-1993A-11-A-1995HVAC-ACR-01-01M-2008HVAC-ACR-01-01M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 81 2321-04 30 6023-33 25 00D3045 112 19501P$32,000.00EAD304008.12
AHU-05Packaged Air Handler, Predictive MaintenanceA-11HVAC-AHU-05-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D305023-33 25 00
AHU-06Air Washer or Wet Coil SystemA-14HVAC-AHU-06-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D309023-33 27 11CFMD304008.02, D304008.02.01, D304008.02.02
AHU-07ApplicationHVAC-AHU-07-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D3090
AHU-08AHU UV Treatment SystemHVAC-AHU-08-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D309023-33 51 15EAD304008.11, D304008.11.01, D304008.11.02
AIR-01Air Dryer, Refrigerated or Regenerative Desiccant TypeA-1HVAC-AIR-01-06MD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 47 00CFMD304008.01.04, D304008.01.02
AIR-02Air CompressorA-4HVAC-AIR-02-06MD30 HVAC (MF2004 DIV. 23 - HVAC)D309023-27 21 00EAD306004
AIR-03Glycol Dry Cooler, Special PurposeA-12HVAC-AIR-03-06MD30 HVAC (MF2004 DIV. 23 - HVAC)D309023-33 45 11MBHD304005.04
AIR-04After-Cooler/SeparatorA-15HVAC-AIR-04-06MD30 HVAC (MF2004 DIV. 23 - HVAC)D3090MBHD302001.01
ALMFire Detection and Alarm SystemF-14, F-15, F-16, D-17, F-18F-14-3-1993 F-18-2-1993F-18-2Y-1995 F-14-A-1995FLSF-ALM-16-01Y-2008

FLSF-ALM-07-01Y-2008

FLSF-ALM-06-06M-2008

FLSF-ALM-02-03M-2008 FLSF-ALM-17-05Y-2012

FLSF-ALM-07-01Y-2012

FLSF-ALM-06-06M-2012

FLSF-ALM-17-01Y-2012

FLSF-ALM-02-03M-2012D40 Fire Protection / D50 Electrical (MF2004 DIV. 28 - Electronic Safety and Security)D503028 31 2321-04 70 50 1023-29 29 00
23-29 31 00D5035 710 19501P$17,656.00EAD503001.XX.XX.XX,XX
ALM-01Alarm Check Valves and AccessoriesF-1, F-1AF-1A-Q-1995 F-1-M-1995FLSF-ALM-01-01MD409023-27 31 19EAD401002.06
ALM-02Fire Supervisory Signals - TestingF-13FLSF-ALM-02-03MD409022-28 30 00EAD503008.04.06
ALM-03Automatic Fire Detection Smoke DetectorsF-14FLSF-ALM-03-01YD40 Fire Protection / D50 Electrical (MF2004 DIV. 28 - Electronic Safety and Security)D409023-29 29 13 11EAD503001.03.02.05
ALM-04Automatic Fire Detection Waterflow AlarmsF-14AF-14A-Q-1995FLSF-ALM-04-03MD409022-28 36 0023-27 11 15EAD503001.03.02.01.02, D503001.03.02.01.03
ALM-05Automatic Fire Detection, Heat DetectorsF-14BF-14B-A-1995FLSF-ALM-05-01YD409023-29 29 13 13EAD503001.03.02.03, D503001.03.02.03.01, D503001.03.02.03.02
ALM-06Smoke Control Systems -Operational TestingFLSF-ALM-06-06MD409023-29 27 11EAD503001.03.03.06.02
ALM-07Fire Alarm Control Panel and Remote AnnunciatorsF-15FLSF-ALM-07-01YD409023-29 31 11, 23-29 31 13EAD503001.03.03.03, D503001.03.03.03.01, D503001.03.03.03.02, D503001.03.03.03.03
ALM-08Fire Alarm Control Panel -Special SystemsF-15AF-15A-A-1995FLSF-ALM-08-01YD409022-10 44 1323-29 31 13EAD503001.03.03.06.01, D503001.03.03.06.02, D503001.03.03.06.03, D503001.03.03.06.04
ALM-09Central Station TransmitterF-15BFLSF-ALM-09-01YD409023-29 31 23 11EAD503001.03.03.04.02
ALM-10Central Station - Receiver and Re-Transmission EquipmentF-15CFLSF-ALM-10-01DD409023-29 31 23 15EAD503001.03.03.04.01, D503001.03.03.04.01
ALM-11Fire Alarm System - RecorderF-16F-15-A-1995FLSF-ALM-11-01WD409023-29 31 25EAD503001.03.03.08
ALM-12Fire Alarm System - Event PrinterF-16AFLSF-ALM-12-03MD409023-29 31 27EAD503001.03.03.07
ALM-13Fire Alarm System -Audio Control PanelF-16BFLSF-ALM-13-01YD409023-29 31 13 15EAD503001.03.03.06.01
ALM-14Fire Alarm System -Remote ControllerF-16CFLSF-ALM-14-01YD409023-29 31 29EAD503001.03.03.10
ALM-15Fire Alarm System -Remote AmplifiersF-16DFLSF-ALM-15-01YD409023-29 31 31EAD503001.03.03.09
ALM-16Manual Fire Alarm Stations -Coded and UncodedF-17F-17-A-1995FLSF-ALM-16-01YD409023-29 29 11EAD503001.03.01, D503001.03.01.01, D503001.03.01.02
ALM-17Fire Life Safety Fire AlarmFLSF-ALM-17-05Y
FLSF-ALM-17-01YD409022-28 31 00
APLAppliance - Washer Dryer EtcN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 23 0021-05 10 30 3523-21 41 0011 23 33 53004$1,600.00EAE109002.08
ARTArtwork Sculptures EtcN/AF-44-6-1993F-44-S-1995ARCS-LND-01-06M-2008ARCS-LND-01-06M-2012RTFE20 Furnishings (MF2004 DIV. 12 - Furnishings)E201012 10 0021-05 20 50 1023-21 45 115E201001.02
ASPAir SeperatorN/AHVAC-AIR-04-06M-2008HVAC-AIR-04-06M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D305021-04 30 50 5023 21 20 0030-04303EAD305004.06
ATPAutomatic Trap PrimerT-8T-08-5-1993T--8-5Y-1995RTFD20303D203003.01.XX.XX.XX
ATSSwitch, Automatic TransferE-36ELEC-ATS-01-01M-2008
ELEC-ATS-01-01Y-2008ELEC-ATS-01-01M-2012
ELEC-ATS-01-01Y-2012E10 Equipment (MF2004 DIV. 11 - Equipment)G401026 36 2321-04 50 10 7023-35 37 11D5015 234 19503P$7,956.00EAG401003.01.XX
ATS-01Automatic Transfer SwitchesE-36E-36-6-1993ELEC-ATS-01-01Y
ELEC-ATS-01-01MD50 Electrical (MF2004 DIV. 26 - Electrical)D501022-26 36 0023-35 37 11EAG401003.01, G401003.01.01, G401003.01.02
AWSAir WasherA-14A-14-1-1993A-14-A-1995HVAC-AHU-06-01Y-2008HVAC-AHU-06-01Y-2012RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D304021-04 30 60 7023-33 27 113D304008.02.XX
BAR-01Security Bollards/BarricadeARCS-BAR-01-06ME201023-11 29 35, 23-39 11 19LFH201005, H201005.01, H201005.01.01, H201005.01.02, H201005.01.03, H201005.01.04, H201005.01.05, H201005.01.06, H201005.02, H201005.02.01, H201005.02.02, H201005.02.03, H201005.03
BAS-01Building Automation System, DDCC-4C-4-3-1993C-4-Q-1995RTFD30 HVAC (MF2004 DIV. 25 - BAS)F105025 14 0021-04 80 10 5023-27 15 00D3065 1004P$17,656.00EAF105002.04
BAS-02Building Automation System, PnuematicC-4C-4-3-1993C-4-Q-1995CTRL-PNU-01-06M-2008RTFD30 HVAC (MF2004 DIV. 25 - BAS)F105025 14 0021-04 80 10 5023-27 15 00D3065 1004P$17,656.00EAF105002.05
BAS-03Building Automation System, Terminal End DevicesC-6C-6-A-1995CTRL-END-01-01Y-2008CTRL-END-01-01Y-2012RTFD30 HVAC (MF2004 DIV. 25 - BAS)F105025 30 0021-04 80 10 5023-27 15 00D3065 1004$17,656.00EAF105002.XX
BATBatteryE-43, E-44, E-45, E-46ELEC-DCS-01-01M-2008
ELEC-DCS-01-01Y-2008ELEC-DCS-01-01Y-2012
ELEC-DCS-01-01M-2012RTFD50 Electrical (MF2004 DIV. 26 - Electrical)D301026 33 1321-04 50 10 2023-35 19 003D301007.XX.XX
BDT-01Metal Enclosed Busways (Busduct)E-37, E-37AELEC-BDT-01-03Y
ELEC-BDT-01-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D502023-35 31 33LFD502001.01.03
BFPBackflow Prevention DeviceV-9V-09-1-1993V-9-SC-1995PLMB-VLV-07-01Y-2008PLMB-VLV-05-01Y-2012D20 Plumbing (MF2004 DIV. 22 - Plumbing)G301033 12 13.1321-04 20 10 9023-27 31 11D4015 100 19502P$1,962.89EAG301002.XX.XX.XX, D202003.XX.XX, D401002.XX.XX
BLR-01BoilerB-2HVAC-BLR-01-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 11 00MBHD302001.03, D302001.04
BLR-02Boiler, ApplicationHVAC-BLR-02-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D3020
BLR-03Boiler, Burner, GasB-2HVAC-BLR-03-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 11 23 13MBHD302001.03.01.02, D302001.03.02.02, D302001.04.01.02, D302001.04.02.02, D302001.13.04.03, D302001.14
BLR-04Boiler, Burner, OilB-2HVAC-BLR-04-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 11 23 13MBHD302001.03.01.01.01, D302001.03.02.01, D302001.04.01.01, D302001.04.02.01, D302001.13.04.04
BLR-05Boiler, Instrument ControlsB-6HVAC-BLR-05-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 11 11MBHD302001.06
BLR-EBoiler, ElectricB-5B-05-1-1993B-5-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 1321-04 30 20 1023-33 11 22D3025 110 19503P$32,730.00EAD302001.XX.XX.XX.XX
BLR-HW1Boiler, Hot Water, Oil/Gas/Comb, up to 120 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 130 19503P$6,336.00EAD302001.XX.XX.XX.XX
BLR-HW2Boiler, Hot Water, Oil/Gas/Comb, 120 to 500 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 130 29503P$6,336.00EAD302001.XX.XX.XX.XX
BLR-HW3Boiler, Hot Water, Oil/Gas/Comb, 500 to 1000 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 130 39502P$6,336.00EAD302001.XX.XX.XX.XX
BLR-HW4Boiler, Hot Water, Oil/Gas/Comb, over 1000 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302123 52 0021-04 30 20 1023-33 11 00D3025 130 49502P$6,336.00EAD302001.03.01.03.04
BLR-MOD1Modular Boiler, 42 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.01
BLR-MOD2Modular Boiler, 57 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.02
BLR-MOD3Modular Boiler, 85 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.03
BLR-MOD4Modular Boiler, 112 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.04
BLR-MOD5Modular Boiler, 140 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.05
BLR-MOD6Modular Boiler, 167 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.06
BLR-MOD7Modular Boiler, 194 MBHD30 HVAC (MF2004 DIV. 23 - HVAC)D3020D302001.15.07
BLR-ST1Boiler, Steam, Oil/Gas/Comb, up to 120 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 140 29503P$6,336.00EAD302001.XX.XX.XX.XX
BLR-ST2Boiler, Steam, Natural Gas or Oil/Gas/CombB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 140 19503P$6,336.00EAD302001.XX.XX.XX.XX
BLR-ST3Boiler, Steam, Oil/Gas/Comb, 500 to 1000 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 140 39503P$6,336.00EAD302001.XX.XX.XX.XX
BLR-ST4Boiler, Steam, Oil/Gas/Comb, over 1000 MBHB-2, B-3, B-4B-02-1-1993B-2-A-1995HVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 52 0021-04 30 20 1023-33 11 00D3025 140 49502P$6,336.00EAD302001.XX.XX.XX.XX
BNGBurner, Gas OilB-3, B-4B-03-1-1993B-3-A-1995HVAC-BLR-09-01Y-2008HVAC-BLR-03-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302021-04 30 20 9023-33 11 23 1323 52 88.10 2000-23203D302003.04.01
BSBHeater, BaseboardR-9R-09-2-1993R-9-2Y-1995HVAC-BSB-01-02Y-2008HVAC-BSB-01-02Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D305023 82 3621-04 30 20 70D3055 110 19504$372.00EAD305004.01.01
BSB-01Radiant Baseboards/Convectors (Steam, Hot Water, or Electric, per section)R-9HVAC-BSB-01-02YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 15 21 13, 23-33 15 29EAD305004, D305004.01, D305004.02, D305004.02.01, D305004.02.02, D305004.02.03, D305004.03, D305004.04, D305004.05
BSDElectric Buss DuctE-37ELEC-BDT-01-02Y-2008
ELEC-BDT-01-01Y-2008ELEC-BDT-01-03Y-2012
ELEC-BDT-01-01Y-2012D50 Electrical (MF2004 DIV. 26 - Electrical)B101021-04 50 20 9023-35 33 2126 25 133B101006.02.XX
BTCBattery ChargerB-1B-1-Q-1995ELEC-DCS-04-01Y-2008
ELEC-DCS-04-01M-2008ELEC-DCS-04-01M-2012
ELEC-DCS-04-01Y-2012RTFD50 Electrical (MF2004 DIV. 26 - Electrical)E101026 33 4321-04 50 10 2023-35 21 003E101008.11
BUFFloor BufferN/ACLNG-SCB-01-03M-2008CLNG-SCB-01-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E101011 24 1321-05 10 30 4023-21 43 19 134E101008.05
BWSBird Wire SystemN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109010 81 1321-02 20 80 8023-19 25 11 11 1110 81 134E109099.02.02
CAOCan OpenerN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 42 0021-05 10 30 804E109002.04.11
CAP-01CapacitorsELEC-CAP-01-01Y
ELEC-CAP-01-03YD50 Electrical (MF2004 DIV. 26 - Electrical)D5090KVAD501099.02, D501099.02.01, D501099.02.02
CAP-02Reactors-Dry-Type, Thermographic SurveyELEC-CAP-02-01Y
ELEC-CAP-02-03YD50 Electrical (MF2004 DIV. 26 - Electrical)D5090KVAD501099.06.01
CAP-03Reactors, Liquid-Filled, Oil LeakageELEC-CAP-03-03Y

ELEC-CAP-03-01Y

ELEC-CAP-03-01MD50 Electrical (MF2004 DIV. 26 - Electrical)D5090KVAD501099.06.02
CBL-01Cables, Low Voltage 600 Volt Maximum, Thermographic SurveyELEC-CBL-01-03Y
ELEC-CBL-01-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D5020LFG402002.01.01.01, G402002.02.01.01
CBL-02Cables, Medium VoltageELEC-CBL-02-03Y
ELEC-CBL-02-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D5020LFG402002.01.01.02, G402002.01.02.01, G402002.01.03.01, G402002.02.01.02
CBS-01Active Chilled BeamD30 HVAC (MF2004 DIV. 23 - HVAC)D3030D304001.03.14.01
CBS-02Passive Chilled BeamD30 HVAC (MF2004 DIV. 23 - HVAC)D3030D304001.03.14.02
CDEClothes Dryer, ElectricN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E101011 23 0021-05 10 30 3523-21 41 31 1111 23 33 53004$1,600.00EAE101004.02.01
CHFChemical FeederX-29X-29-6-1993X-29-S-1995HVAC-WTM-03-06M-2008HVAC-WTM-03-06M-2012RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D302043 22 3923-27 55 3123 53 24.10 0200-04203$1,730.00EAD302001.05
CHL-A1Chiller, Absorption unit, up to 500 tonsR-3R-03-1-1993R-3-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1321-04 30 30 1023-33 21 11D3035 150 19503P$141,950.00EAD303001.01.XX.XX.XX
CHL-A2Chiller, Absorption unit, 500 to 5000 tonsR-3R-03-1-1993R-3-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1321-04 30 30 1023-33 21 11D3035 150 29503P$141,950.00EAD303001.01.XX.XX.XX
CHL-CW1Chiller, Centrifugal, water cooled, up to 100 tonsR-5R-05-1-1993R-5-A-1995HVAC-CLR-02-01Y-2008HVAC-CLR-01-03M-2012
HVAC-CLR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1621-04 30 30 1023-33 21 13 13D3035 140 19503P$146,300.00EAD303001.01.01.02.01
CHL-CW2Chiller, Centrifugal, water cooled, over 100 tonsR-5R-05-1-1993R-5-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1621-04 30 30 1023-33 21 13 13D3035 140 29503P$146,300.00EAD303001.01.01.XX.XX
CHL-MB1Magnetic Bearing Chiller, Less 500 TonsD30 HVAC (MF2004 DIV. 23 - HVAC)D3030TOND303001.01.01.03.01
CHL-MB2CHL-MB2: Magnetic Bearing Chiller, 500-1000 TonsD30 HVAC (MF2004 DIV. 23 - HVAC)D3030TOND303001.01.01.03.02
CHL-MB3CHL-MB3: Magnetic Bearing Chiller, over 1000 TonsD30 HVAC (MF2004 DIV. 23 - HVAC)D3030TOND303001.01.01.03.03
CHL-MOD1Modular Chiller, 20-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.01
CHL-MOD2Modular Chiller, 25-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.02
CHL-MOD3Modular Chiller, 30-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.03
CHL-MOD4Modular Chiller, 35-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.04
CHL-MOD5Modular Chiller, 40-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.05
CHL-MOD6Modular Chiller, 45-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.06
CHL-MOD7Modular Chiller, 50-TonD30 HVAC (MF2004 DIV. 23 - HVAC)D3030G305001.01.07.07
CHL-RA1Chiller, Recip, Air Cooled, up to 25 tonsR-6R-06-1-1993R-6-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1921-04 30 30 1023-33 21 13 15D3035 130 19503P$50,700.00EAD303001.01.XX.XX.XX
CHL-RA2Chiller, Recip, Air Cooled, over 25 tonsR-6R-06-1-1993R-6-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1921-04 30 30 1023-33 21 13 15D3035 130 29503P$50,200.00EAD303001.01.XX.XX.XX
CHL-S1Chiller, Screw, Water CooledR-7R-07-6-1993R-7-S-1995HVAC-CLR-02-01Y-2008HVAC-CLR-02-01Y-2012
HVAC-CLR-08-02Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 2621-04 30 30 1023-33 21 13 21D3035 160 19503P$146,300.00EAD303001.01.05.XX.XX
CHL-S2Chiller, Screw, Water CooledR-7R-07-6-1993R-7-S-1995HVAC-CLR-02-01Y-2008HVAC-CLR-08-02Y-2012
HVAC-CLR-02-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 2621-04 30 30 1023-33 21 13 21D3035 160 29503P$146,300.00EAD303001.01.05.XX.XX
CHL-W1Chiller, Recip, Water Cooled, up to 50 tonsR-6R-06-1-1993R-6-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1921-04 30 30 1023-33 21 13 15D3035 135 19503P$27,925.00EAD303001.01.04.XX.XX
CHL-W2Chiller, Recip, Water Cooled, over 50 tonsR-6R-06-1-1993R-6-A-1995HVAC-CLR-04-01Y-2008HVAC-CLR-04-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 64 1921-04 30 30 1023-33 21 13 15D3035 135 29503P$27,925.00EAD303001.01.04.XX.XX
CHM-01Chemical Storage TanksT-6T-6-A-1995TANK-CHM-01-01Y23-27 29 00EAF104002.01
CKB-01Circuit Breakers, Air, Insulated-Case/Molded-CaseELEC-CKB-01-03Y
ELEC-CKB-01-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D501023-35 29 11, 23-35 29 17KVAD501003.01.01
CKB-02Circuit Breakers, Air, Low-Voltage PowerE-26ELEC-CKB-02-03Y
ELEC-CKB-02-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D501023-35 29 11KVAD501003.01.01
CKB-03Circuit Breakers, Air, Medium VoltageELEC-CKB-03-03Y
ELEC-CKB-03-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D501023-35 29 11KVAD501003.01.01
CKB-04Circuit Breakers, Oil, Medium-VoltageELEC-CKB-04-03Y

ELEC-CKB-04-01M

ELEC-CKB-04-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D501023-35 29 19KVAD501003.01.05
CKB-05Circuit Breakers, Vacuum, Medium-VoltageELEC-CKB-05-03Y
ELEC-CKB-05-01YD50 Electrical (MF2004 DIV. 26 - Electrical)D501023-35 29 21KVAD501003.01.06
CLKClocksC-1C-01-6-1993C-1-S-1995ELEC-CLK-01-06M-2008ELEC-CLK-01-06M-2012D50 Electrical (MF2004 DIV. 26 - Electrical)D503012 46 1921-05 20 50 4023-21 37 13 1327 53 13.504D503006.02
CLK-01Clocks, Central SystemC-1ELEC-CLK-01-06MD50 Electrical (MF2004 DIV. 26 - Electrical)D5090EAD503006.02
CLR-01Central Chilled Water Package Unit:R-4HVAC-CLR-01-01Y
HVAC-CLR-01-03MD30 HVAC (MF2004 DIV. 23 - HVAC)D3050EAD305006.02.01.02
CLR-02Rotary Screw & Scroll ChillerR-6-A-1995HVAC-CLR-02-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 21 13 19, 23-33 21 13 21, and 23-33 21 13 23TOND303001.01.05, D303001.01.06, G305002.01.05, G305002.01.06
CLR-03Centrifugal ChillerR-5R-5-A-1995HVAC-CLR-03-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 21 13 13TOND303001.01.01, G305002.01.01
CLR-04Refrigeration Machine, Absorption UnitR-3HVAC-CLR-04-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 21 11EAD303001.04.01.02
CLR-05Chiller Control PanelHVAC-CLR-05-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D3030D306002.09
CLR-06Refrigerant MonitorR-15HVAC-CLR-06-01MD30 HVAC (MF2004 DIV. 23 - HVAC)D306022-28 35 0023-33 51 11EAD303001.12
CLR-07Refrigerant Purge UnitsR-14HVAC-CLR-07-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D306023-33 51 13EAD303001.09
CLR-08Vibration Analysis, ChillersHVAC-CLR-08-02YD30 HVAC (MF2004 DIV. 23 - HVAC)D3090
CLR-09Non-Destructive Tube Analysis (Eddy Current Analysis)R-13HVAC-CLR-09-03YD30 HVAC (MF2004 DIV. 23 - HVAC)D3060
CLS-01Coils Cooling, Heating, Preheat, Reheat, Etc.C-3C-3-A-1995HVAC-CLS-01-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D302023-33 35 00EAD304001.01, D304001.05
CMDCarbon-Monoxide Detection SensorsFLSF-FEX-01-05Y-2008FLSF-FEX-01-05Y-2012RTFD40 Fire Protection / D50 Electrical (MF2004 DIV. 28 - Electronic Safety and Security)D306028 31 4921-04 70 5023-29 39 002$5,175.00EAD306001.01.01
CMICarbon Dioxide (CO2) Concentration Measuring InstrumentN/ARTFD30 HVAC (MF2004 DIV. 23 - HVAC)D306023-27 11 17 133D306001.01.03
CMPAir CompressorA-4A-04-6-1993A-4-S-1995HVAC-AIR-02-06M-2008HVAC-AIR-02-06M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D401022 15 1923-27 21 0023-27 21 13D3095 114 19503P$1,804.00EAD401002.02.XX.XX
CMP-RAir Compressor, RecipA-4A-04-6-1993A-4-S-1995HVAC-AIR-02-06M-2008HVAC-AIR-02-06M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D306022 15 19.1321-04 20 60 1023-27 21 15D3095 118 19503P$1,804.00EAD306004.03
CND-01Condensing Unit, RefrigerationC-24HVAC-CND-01-01M
HVAC-CND-01-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D303023-33 37 00
COFCoffee Maker/UrnN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 42 0021-05 10 30 8023-21 21 13 13 1111 42 10 1840-604$1,675.00EAE109002.04.07
COLCoil, Heating/CoolingC-3C-03-1-1993C-3-A-1995HVAC-CLS-01-01Y-2008HVAC-CLS-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 82 1621-04 3023-33 35 1123 82 163D304008.13.01
CONControl PanelC-8C-08-6-1993C-8-A-1995CTRL-DDC-06-01Y-2008CTRL-DDC-06-01Y-2012RTFD50 Electrical (MF2004 DIV. 26 - Electrical)D503040 95 133D503001.XX.XX.XX.XX
CPZCathodic Protection ZincN/AD50 Electrical (MF2004 DIV. 26 - Electrical)G409040 46 4221-04 50 80 4026 42 16.504G409001.03
CRACComputer Room A.C.1 (CRAC Unit)A-6, A-7A-06-1-1993A-6-A-1995HVAC-ACR-01-01M-2008HVAC-ACR-01-01M-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D304023 81 2321-04 30 30 9023-33 39 11 11D3045 112 19501P$20,775.00EAD304008.12.01
CRN-01Crane, ElectricC-13MHDL-CRN-01-03MD101022-41 22 1323-23 17 23 15EAD109007.01
CTRCooling TowerC-9, C-10C-09-1-1993
C-10-3-1993C-9-A-1995
C-10-Q-1995HVAC-TWR-01-01Y-2008
HVAC-TWR-01-03M-2008HVAC-TWR-01-03M-2012
HVAC-TWR-01-01Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D303023 65 1321-04 30 30 1023-33 23 00D3035 110 19503P$25,825.00EAD303001.05.01.XX
CUTCutter, FoodN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 42 0021-05 10 30 8023-21 21 31 1911 42 10 85804$5,250.00EAE109002.05.XX
CVCVideo Control SystemN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E102028 23 133E102009.06
CWDClothes Washer, DomesticN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E101011 23 0021-05 10 30 3523-21 41 4111 23 33 53004$1,600.00EAE101004.05.01
DAVDavits/Roof Anchors/Fall ProtectionW-5W-05-1-1993W-5-A-1995ARCS-DAV-01-01Y-2012RTFB20 Exterior Enclosure (MF2004 DIV. 08 - Openings)B102014 80 0021-04 10 8023-27 71 002P$14.03SFB102003.09.01
DAV-01DavitsARCS-DAV-01-01YD101022-41 22 33EAD109007
DCS-01DC Battery System, Lead AcidE-43E-43-3-1993ELEC-DCS-01-01Y
ELEC-DCS-01-01MD50 Electrical (MF2004 DIV. 26 - Electrical)D509022-26 33 0023-35 19 00
DCS-02Primary Battery (Dry Cell)E-44AELEC-DCS-02-01MD50 Electrical (MF2004 DIV. 26 - Electrical)D509022-26 33 0023-35 19 13 13
DCS-03Nickel Cadmium BatteryE-44ELEC-DCS-03-03MD50 Electrical (MF2004 DIV. 26 - Electrical)D509022-26 33 0023-35 19 15 21
DCS-04DC Battery System, ChargersB-1ELEC-DCS-04-01Y
ELEC-DCS-04-01MD50 Electrical (MF2004 DIV. 26 - Electrical)D509023-35 21 00
DCTSwitch, DisconnectE-34, E-34AELEC-SWT-02-01Y-2008ELEC-SWT-02-01Y-2012E10 Equipment (MF2004 DIV. 11 - Equipment)G401026 28 1621-04 50 20 1023-35 29 274$30,700.00EAG401003.02.XX
DDC-01BAS ServerCTRL-DDC-01-01M

CTRL-DDC-01-01W

CTRL-DDC-01-03M

CTRL-DDC-01-01YD503022-25 50 0023-27 15 00EAF105002.02
DDC-02BAS Server Client WorkstationCTRL-DDC-02-01M

CTRL-DDC-02-01Y

CTRL-DDC-02-03M

CTRL-DDC-02-01WD503022-25 51 0023-27 15 00EAF105002.03
DDC-03Network, Management LevelCTRL-DDC-03-01Y
CTRL-DDC-03-03MD503022-27 22 00EAD306002.12
DDC-04Network, Building LevelCTRL-DDC-04-01Y
CTRL-DDC-04-03MD503022-27 22 00EAD306002.11
DDC-05Field PanelCTRL-DDC-05-01YD5030EAD306002.09
DDC-06ControllerM-10C-8-A-1995CTRL-DDC-06-01YD503022-25 50 0023-27 15 00EAD306002.06
DDC-07Sensors, ElectronicCTRL-DDC-07-01YD509022-25 56 00 and 22-25 58 00EAD306002.07
DDC-08Alarm MaintenanceCTRL-DDC-08-01MD503022-28 31 00EAD306002.01
DDC-09BAS Wireless Electronic/Pneumatic end devices (Thermostats)CTRL-DDC-09-06M
CTRL-DDC-09-01YD503023-27 11 11 23EAD306002.04
DEADeaerator TankT-2T-02-1-1993T-2-A-1995TANK-WTR-01-03Y-2008TANK-WTR-01-03Y-2012D30 HVAC (MF2004 DIV. 23 - HVAC)D302023 53 1621-04 30 30 9023-27 55 23D3025 210 19504P$3,534.00EAD302001.02.05
DESDeaerating SystemN/AHVAC-BLR-01-01Y-2008HVAC-BLR-01-01Y-2012RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D302023 53 1621-04 30 20 9023-27 55 234D302001.02.04
DETDetector, LeakN/ATANK-UST-02-01M-2008RTFF10 Special ConstructionD307021-04 70 5023-39 35 11 174D307001.05
DFBDefibrillatorN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)C103010 43 0021-05 10 9023-25 21 13 19 1110 43 13 0050/01002EAC103009.03.01
DFFFryer, Pressurized Broaster, Gas/ElectricK-102G-21-6-1993K-102-Q-1995KTCH-FRY-01-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 44 0021-05 10 30 8023-21 21 13 21 11E1095 320 39504EAE109002.04.03.XX
DFSDiffuser-Linear and Lay inN/ARTFD30 HVAC (MF2004 DIV. 23 - HVAC)D304023 37 1321-04 30 50 5023-33 49 11 11 1123 37 13.103D304001.03.08.03
DKLDock LevelerN/AMHDL-LFT-03-03M-2008MHDL-LFT-03-03M-2012E10 Equipment (MF2004 DIV. 11 - Equipment)D109011 13 19.1321-05 10 10 5023-23 23 1311 13 19 4500/46504EAD109006.02.XX
DMP-01Motorized Dampers, Pneumatic or ElectricC-2C-2-S-1995HVAC-DMP-01-01YD30 HVAC (MF2004 DIV. 23 - HVAC)D305023-33 29 00EAD304001.07
DMW-01DumbwaiterD-2MHDL-DMW-01-03MD109022-14 10 0023-23 17 11F201005.03
DORExterior DoorsD-5-6-1993D-5-S-1995ARCS-DOR-04-06M-2008ARCS-DOR-04-06M-2012RTFB20 Exterior Enclosure (MF2004 DIV. 08 - Openings)B203008 10 0021-02 20 5023-17 11 004$18.82SFB20300X.XX.XX.XX.XX.XX.XX
DOR-01Door, Power OperatedD-1ARCS-DOR-01-06M,
FLSF-DOR-01-03MC102022-08 42 00, 22-08 10 00, and 22-08 30 0023-17 11 00EAB203001.02
DOR-02Door; Hydraulic, Electric or Pneumatic OperatedD-4ARCS-DOR-02-03MC102022-08 42 00, 22-08 10 00, and 22-08 30 0023-17 11 00EAB203003.02
DOR-03Door, Manual, OverheadD-10ARCS-DOR-03-06MC102022-08 42 00, 22-08 10 00, and 22-08 30 0023-17 11 13 25, 23-17 11 15 31, 23-17 11 17 25, 23-17 11 19 21, 23-17 11 31 11 11EAB203004.01.01
DOR-04Door, Manually Operated EntranceARCS-DOR-04-06MC102022-08 42 00, 22-08 10 00, and 22-08 30 0023-17 11 00EAB203001.01
DPPDamper, PoweredC-2C-02-6-1993C-2-S-1995HVAC-DMP-01-01Y-2008HVAC-DMP-01-01Y-2012RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D304023 33 1321-04 30 50 5023-33 29 192D304001.07.10.XX.XX.XX
DPSDifferenatial Pressure SwitchN/AE-25A-1-1993
E-25A-3-1993E-25A-A-1995
E-25A-3Y-1995RTFD30 HVAC (MF2004 DIV. 23 - HVAC)D306023-35 37 33 113D306001.06.07
DRDDrink DispenserN/ARTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 46 0021-05 10 30 8023-21 21 254E109002.06.XX
DRNDrainX-39X-39-1-1993PLMB-DRN-02-01Y-2008PLMB-DRN-02-01Y-2012RTFD20 Plumbing (MF2004 DIV. 22 - Plumbing)D204022 13 19.1321-04 20 20 9023-31 27 0022 13 19.133D204002.XX
DRN-01Roof Drains, Downspout, and Gutter InspectionD-3PLMB-DRN-01-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D204023-13 41 39EAD204002
DRN-02Drains: Areaway, Driveway, StormD-6PLMB-DRN-02-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D204022-22 14 26, 22-33 40 00, 22-33 44 0023-39 29 11EAD204003.05
DSEDuplex Sewage EjectorS-6S-06-1-1993S-6-A-1995PLMB-DWV-02-01Y-2008PLMB-DWV-02-01Y-2012D20 Plumbing (MF2004 DIV. 22 - Plumbing)D203022 13 0021-04 20 20 1023-27 17 35 11G3025 410 19503P$2,151.00EAD203004.03.XX
DSH-01Dishwashing MachineK-101KTCH-DSH-01-03ME201023-21 21 19 11 11EAE109002.07
DSH-1Dishwasher - ElectK-101G-15B-6-1993
G-15A-1-1993K-101-Q-1995KTCH-DSH-01-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 48 1321-05 10 30 8023-21 21 19E1095 322 19504EAE109002.07.XX.XX
DSH-2Dishwasher - SteamK-101BG-15B-6-1993
G-15A-1-1993K-101B-S-1995KTCH-DSH-01-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 48 1321-05 10 30 8023-21 21 19 11 11E1095 322 29504EAE109002.07.01.02
DSH-3Dish/Tray Busing ConveyorK-100G-15B-6-1993
G-15A-1-1993K-100-Q-1995KTCH-DSH-01-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)E109011 43 0021-05 10 30 8023-21 21 19 11 15E1095 322 29504EAE109002.07.04
DTTTransformer, DryE-33ELEC-TRN-01-01Y-2008
ELEC-TRN-01-02Y-2008ELEC-TRN-01-01Y-2012
ELEC-TRN-01-03Y-2012E10 Equipment (MF2004 DIV. 11 - Equipment)G401026 12 1621-04 50 20 1023-35 13 17 15 11D5015 240 19503P$33,945.00EAG401002.01.XX.XX
DWS-01Domestic Hot Water Heater ? GasH-2PLMB-DWS-01-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D201023-31 29 13 13GALD202003.04.01.02, D202003.04.02.02
DWS-02Domestic Hot Water Heater - ElectricH-3PLMB-DWS-02-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D201023-31 29 13 11GALD202003.04.01.01, D202003.04.02.01
DWS-03Hot Water Heater Steam CoilH-5PLMB-DWS-03-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D2010GALD202003.04.02.04
DWS-04Water SoftenerW-3PLMB-DWS-04-06MD20 Plumbing (MF2004 DIV. 22 - Plumbing)D2010EAD202005.08
DWS-05Water FilterW-4PLMB-DWS-05-06MD20 Plumbing (MF2004 DIV. 22 - Plumbing)D2010EAD307001.01
DWV-01Sewage Ejector (Pneumatic Tank Type Ejectors)S-2PLMB-DWV-01-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D209023-27 17 35GPMD203004.03, D203004.03.01, D203004.03.02
DWV-02Sewage Ejector, Sump TypeS-6PLMB-DWV-02-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D2090GPMD203004.03.03
DWV-03Sump PumpS-7PLMB-DWV-03-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D2030GPMG303003.05
DWV-04Emergency WashW-2PLMB-DWV-04-01WD20 Plumbing (MF2004 DIV. 22 - Plumbing)D209023-29 37 13EAD201099.02
DWV-05Emergency ShowerX-37PLMB-DWV-05-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D209023-29 37 15EAD201099.03
DWV-06Septic Tank and Drain FieldX-39PLMB-DWV-06-01YD20 Plumbing (MF2004 DIV. 22 - Plumbing)D209022-33 47 23GAL, LFG302005.01, G302006
EFPFlagpole, ElectricX-22P-21-3-1993X--22-Q-1995ARCS-LND-04-03M-2008ARCS-LND-04-03M-2012RTFG20 Site Improvements (MF2004 DIV. 32 - Exterior Improvements)H204010 75 1321-07 20 60 3523-11 29 25 1110 75 16 28204$5,800.00EAH204009.01
EHCExhaust Hood, Commercial KitchenF-39F-39-6-1993F-39-S-1995E10 Equipment (MF2004 DIV. 11 - Equipment)E109023 38 1321-04 30 60 3023-21 21 41 11 1123 34 23.10 6900-69303E109002.04.02.03
EHFExhaust Hood, FumeN/A?D209023 38 1621-04 30 60 3023-33 31 1511 31 13.533D209002.01
ELTEmergency LightingL-3L-03-1-1993L-3-A-1995ELEC-LTG-06-03M-2008ELEC-LTG-06-03M-2012RTFE10 Equipment (MF2004 DIV. 11 - Equipment)D502026 52 0021-04 50 40 5023-35 47 132$91.00EAD502002.02.03.02
ELV-01Elevators, HydraulicE-1, E-2, E-3, E-4VTRN-ELV-01-01Y
VTRN-ELV-01-06MD101022-14 20 0023-23 11 11 13EAD101002.04
ELV-02Elevators, ElectricE-1, E-2, E-3, E-4VTRN-ELV-02-05Y

VTRN-ELV-02-01Y

VTRN-ELV-02-06MD101022-14 20 0023-23 11 11 11EAD101002.06
ELV-03Elevators, Electric or HydraulicE-1, E-2, E-3, E-4E-1-M-1995

E-2-Q-1995 E-3-S-1995 E-4-A-1995

E-7-5Y-1995 VTRN-ELV-03-01W

VTRN-ELV-03-03M

VTRN-ELV-03-01MD101022-14 20 0023-23 11 11EAD101002.04, D101002.06

This is the start of the file's text. The full file is on GovTribe.