693KA8-24-R-00012 - Section B Attachment B.1.xlsx
XLSX spreadsheet 116 KB Posted
- Solicitation number
- 693KA8-24-R-00012
About this file
This document is a pricing schedule (Attachment B.1) related to a Request for Proposals (RFP) for a federal contract opportunity for Engine Generator Systems (EGS). The RFP, solicitation number 693KA8-24-R-00012, is for the manufacture, maintenance, and life cycle in-service support of COTS/NDI EGS. The period of performance is 10 years, with a 2-year base period and four 2-year option periods.
The pricing schedule includes line items for various EGS equipment, such as stationary and towable generators, automatic transfer switches, day tanks, load banks, and silencers/mufflers. The line items are primarily firm-fixed-price, with some not-to-exceed and labor-hour priced items. The schedule also includes line items for ancillary services such as start-up, delivery, training, and engineering support. Specific details are provided for the equipment configurations, quantities, and pricing for the base and option periods.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Instructions
| ENTER YOUR COMPANY NAME HERE |
| B.1-693KA8-24-R-00012 PRICING Schedule |
| Instructions: |
| Overall Offeror Instructions for Exhibit B.1-EG Pricing Schedule. |
| 1. Enter Company Name in cell A1 of this sheet. |
| BLUE FIELDS are to be completed by the Offeror. |
| RED FIELDS are Not-to-Exceed |
| WHITE FIELD are information only no actions are required. |
| 2. Price Schedule Tab Instructions: |
| a. Pricing Column: Indicates whether the CLIN is Firm Fixed Price (FFP); Labor Hour (LH); or Not-to-Exceed (Cost Reimbursement) |
| b. Contract Line Item Number (CLIN): All CLINs are numbered with a placeholder (X); which will be replaced by a 0 for the base period; 1 for the first option period; 2 for the second option period; 3 for the third option period; and 4 for the fourth and final option period. |
| c. Item, Unit; Est. Quantity; Price per Unit; and Est Total: These are self explanatory. |
| d. FFP CLINs: The Offerors must complete all sections highlighted in BLUE on the FFP CLINs with their unit price for the line items. |
e. Not-to-Exceed (NTE) or Cost Reimbursement CLINs: These are prepopulated
f. LH CLINs: The Offerors must complete all sections highlighted in BLUE with the proposed fully loaded FFP labor rate for each labor category for the base year and all options.
g. Total Price: The total Price for each period and for the total contract is auto-calculated.
Base Period
| Pricing | CLIN | ITEM | Unit | Base Period | |||
| Est. Qty | Price Per Unit | Est. Total | |||||
| EQUIPMENT/ HARDWARE | |||||||
| X101 | Stationary Generator, Industrial, Diesel 277/480 Volt, 3 Phase, Wye, 4 Wire, 100 kW to 1,500 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X101A | 100 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101B | 125 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101C | 150 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101D | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101E | 200 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101F | 250 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101G | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101H | 400 kW Generator: Rail Mounted Radiator | EA | 5 | $0.00 | ||
| FFP | X101HA | 400 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101I | 500 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101IA | 500 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101J | 600 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101JA | 600 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101K | 750 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101KA | 750 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101L | 800 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101LA | 800 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101M | 1,000 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101MA | 1,000 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101N | 1,250 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101NA | 1,250 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101O | 1,500 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101OA | 1,500 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| X102 | Stationary Generator, Industrial, Diesel 120/208 Volt, 3 Phase, Wye, 4 Wire, 10 kW to 300 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X102A | 10 - 15 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X102B | 20 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102C | 30 - 35 kW Generator: Rail Mounted Radiator | EA | 18 | $0.00 | ||
| FFP | X102D | 50 kW Generator: Rail Mounted Radiator | EA | 17 | $0.00 | ||
| FFP | X102E | 80 kW Generator: Rail Mounted Radiator | EA | 7 | $0.00 | ||
| FFP | X102F | 100 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X102G | 125 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102H | 150 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102I | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 30 | $0.00 | ||
| FFP | X102J | 200 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102K | 250 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X102L | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| X103 | Stationary Generator, Industrial, Diesel 120/240 Volt, 3 Phase, Delta, 4 Wire. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X103A | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| X104 | Stationary Generator, Industrial, Diesel 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X104A | 10 - 15 kW | EA | 1 | $0.00 | ||
| FFP | X104B | 20 kW | EA | 10 | $0.00 | ||
| FFP | X104C | 30 - 35 kW | EA | 10 | $0.00 | ||
| FFP | X104D | 50 kW | EA | 5 | $0.00 | ||
| X105 | Stationary Generator, Industrial, Propane 120/208 Volt, 3 Phase, Wye, 4 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X105A | 10 -15 kW | EA | 1 | $0.00 | ||
| FFP | X105B | 25 kW | EA | 10 | $0.00 | ||
| FFP | X105C | 39 - 49 kW | EA | 35 | $0.00 | ||
| FFP | X105D | 50 - 60 kW | EA | 3 | $0.00 | ||
| FFP | X105E | 100 kW | EA | 7 | $0.00 | ||
| FFP | X105F | 125 kW | EA | 5 | $0.00 | ||
| FFP | X105G | 150 kW | EA | 5 | $0.00 | ||
| X106 | Stationary Generator, Industrial, Propane 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X106A | 10 - 20 kW | EA | 1 | $0.00 | ||
| FFP | X106B | 25 - 44 kW | EA | 18 | $0.00 | ||
| FFP | X106C | 50 - 60 kW | EA | 7 | $0.00 | ||
| FFP | X106D | 100 kW | EA | 1 | $0.00 | ||
| X107 | Towable Generator, Industrial, Diesel, Multiple Voltage Configurations Switchable to: 120/208v 3 phase, or 120/240v single phase, or 277/480v 3 phase | ||||||
| FFP | X107A | 20 - 29 kW | EA | 60 | $0.00 | ||
| FFP | X107B | 50 - 60 kW | EA | 30 | $0.00 | ||
| FFP | X107C | 100 kW | EA | 10 | $0.00 | ||
| FFP | X107D | 150 kW | EA | 10 | $0.00 | ||
| FFP | X107E | 200 kW | EA | 10 | $0.00 | ||
| X108 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X108A | 150 AMP | EA | 2 | $0.00 | ||
| FFP | X108B | 260 AMP | EA | 8 | $0.00 | ||
| FFP | X108C | 400 AMP | EA | 25 | $0.00 | ||
| FFP | X108D | 600 AMP | EA | 6 | $0.00 | ||
| FFP | X108E | 800 AMP | EA | 10 | $0.00 | ||
| FFP | X108F | 1,000 AMP | EA | 6 | $0.00 | ||
| FFP | X108G | 1,200 AMP | EA | 5 | $0.00 | ||
| FFP | X108H | 1,600 AMP | EA | 3 | $0.00 | ||
| FFP | X108I | 2,000 AMP | EA | 1 | $0.00 | ||
| FFP | X108J | 2,600 AMP | EA | 1 | $0.00 | ||
| X109 | Portable, Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X109A | 150A | EA | 20 | $0.00 | ||
| FFP | X109B | 260A | EA | 15 | $0.00 | ||
| FFP | X109C | 400A | EA | 10 | $0.00 | ||
| FFP | X109D | 600A | EA | 5 | $0.00 | ||
| FFP | X109E | 800A | EA | 5 | $0.00 | ||
| X110 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X110A | 150 AMP | EA | 1 | $0.00 | ||
| FFP | X110B | 260 AMP | EA | 1 | $0.00 | ||
| FFP | X110C | 400 AMP | EA | 1 | $0.00 | ||
| FFP | X110D | 600 AMP | EA | 1 | $0.00 | ||
| FFP | X110E | 800 AMP | EA | 1 | $0.00 | ||
| FFP | X110F | 1,000 AMP | EA | 1 | $0.00 | ||
| FFP | X110G | 1,200 AMP | EA | 1 | $0.00 | ||
| FFP | X110H | 1,600 AMP | EA | 1 | $0.00 | ||
| FFP | X110I | 2,000 AMP | EA | 1 | $0.00 | ||
| FFP | X110J | 2,600 AMP | EA | 1 | $0.00 | ||
| X111 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X111A | 150 AMP | EA | 35 | $0.00 | ||
| FFP | X111B | 260 AMP | EA | 60 | $0.00 | ||
| FFP | X111C | 400 AMP | EA | 20 | $0.00 | ||
| FFP | X111D | 600 AMP | EA | 31 | $0.00 | ||
| FFP | X111E | 800 AMP | EA | 36 | $0.00 | ||
| FFP | X111F | 1,000 AMP | EA | 16 | $0.00 | ||
| FFP | X111G | 1,200 AMP | EA | 2 | $0.00 | ||
| X112 | Portable Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X112A | 150A | EA | 45 | $0.00 | ||
| FFP | X112B | 260A | EA | 45 | $0.00 | ||
| FFP | X112C | 400A | EA | 45 | $0.00 | ||
| FFP | X112D | 600A | EA | 35 | $0.00 | ||
| FFP | X112E | 800A | EA | 10 | $0.00 | ||
| X113 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X113A | 150 AMP | EA | 1 | $0.00 | ||
| FFP | X113B | 260 AMP | EA | 1 | $0.00 | ||
| FFP | X113C | 400 AMP | EA | 1 | $0.00 | ||
| FFP | X113D | 600 AMP | EA | 1 | $0.00 | ||
| FFP | X113E | 800 AMP | EA | 1 | $0.00 | ||
| FFP | X113F | 1,000 AMP | EA | 1 | $0.00 | ||
| FFP | X113G | 1,200 AMP | EA | 1 | $0.00 | ||
| FFP | X114 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Open Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 1 | $0.00 | ||
| FFP | X115 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Closed Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 1 | $0.00 | ||
| X116 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X116A | 150 Amp | EA | 18 | $0.00 | ||
| FFP | X116B | 260 Amp | EA | 25 | $0.00 | ||
| FFP | X116C | 400 Amp | EA | 8 | $0.00 | ||
| X117 | Portable Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X117A | 150A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117B | 260A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117C | 400A Open Trans Portable ATS, 240V | EA | 5 | $0.00 | ||
| X118 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X118A | 150 Amp | EA | 1 | $0.00 | ||
| FFP | X118B | 260 Amp | EA | 1 | $0.00 | ||
| FFP | X118C | 400 Amp | EA | 1 | $0.00 | ||
| X119 | X119 | Day Tank, Fill pump, Reverse pump, Secondary containment | |||||
| FFP | X119A | Size: 10 Gal | EA | 26 | $0.00 | ||
| FFP | X119B | Size: 25 Gal | EA | 75 | $0.00 | ||
| FFP | X119C | Size: 50 Gal | EA | 68 | $0.00 | ||
| FFP | X119D | Size: 60 Gal | EA | 60 | $0.00 | ||
| FFP | X119E | Size: 75 Gal | EA | 41 | $0.00 | ||
| FFP | X119F | Size: 100 Gal | EA | 1 | $0.00 | ||
| FFP | X119G | Size: 150 Gal | EA | 1 | $0.00 | ||
| FFP | X119H | Size: 275 Gal | EA | 1 | $0.00 | ||
| FFP | X119I | Size: 300 Gal | EA | 1 | $0.00 | ||
| FFP | X119J | Size: 500 Gal | EA | 1 | $0.00 | ||
| X120 | Remote Load Banks, Balanced Resistive Load | ||||||
| FFP | X120A | 100kW, 208V, 3Ø | EA | 25 | $0.00 | ||
| FFP | X120B | 100kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120C | 150kW, 208V, 3Ø | EA | 30 | $0.00 | ||
| FFP | X120D | 150kW, 240V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120E | 150kW, 480V, 3Ø | EA | 20 | $0.00 | ||
| FFP | X120F | 200kW, 208V, 3Ø | EA | 10 | $0.00 | ||
| FFP | X120G | 200kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120H | 250kW, 208V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120I | 250kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120J | 300kW, 480V, 3Ø | EA | 5 | $0.00 | ||
| FFP | X120K | 350kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120L | 400kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120M | 500kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120N | 600kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120O | 750kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120P | 800kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120Q | 1000kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120R | 1250kW, 480V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120S | 1500kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| X121 | Silencer / Muffler | ||||||
| FFP | X121A | Silencer, Industrial for CLIN X104A | EA | 150 | $0.00 | ||
| FFP | X121B | Silencer, Critical for CLIN X104A | EA | 1 | $0.00 | ||
| FFP | X121C | Silencer, Industrial for CLIN X104D | EA | 70 | $0.00 | ||
| FFP | X121D | Silencer, Critical for CLIN X104D | EA | 1 | $0.00 | ||
| FFP | X121E | Silencer, Residential for CLINs X102G & X102GA | EA | 130 | $0.00 | ||
| FFP | X121F | Silencer, Critical for CLINs X102G & X102GA | EA | 4 | $0.00 | ||
| FFP | X121G | Silencer, Residential for CLINs X101G & X101GA | EA | 9 | $0.00 | ||
| FFP | X121H | Silencer, Critical for CLINs X101G & X101GA | EA | 2 | $0.00 | ||
| FFP | X121I | Silencer, Residential for CLINs X101I & X101IA | EA | 3 | $0.00 | ||
| FFP | X121J | Silencer, Critical for CLINs X101I & X101IA | EA | 2 | $0.00 | ||
| FFP | X121K | Silencer, Residential for CLINs X101L & X101LA | EA | 3 | $0.00 | ||
| FFP | X121L | Silencer, Critical for CLINs X101L & X101LA | EA | 1 | $0.00 | ||
| FFP | X121M | Silencer, Residential for CLINs X101M & X101MA | EA | 1 | $0.00 | ||
| FFP | X121N | Silencer, Critical for CLINs X101M & X101MA | EA | 3 | $0.00 | ||
| FFP | X121O | Silencer, Critical for CLINs X101M, X101MA, X101N, & X101NA | EA | 1 | $0.00 | ||
| FFP | X121P | Silencer, Hospital for CLINs X101M, X101MA, X101N, & X101NA | EA | 1 | $0.00 | ||
| CR | X122 | Radiator, Remote - price based on site specific configuration. May be horizontal or vertical, stainless steel or aluminum. | EA | NTE | $354,000.00 | ||
| FFP | X123 | Remote Annunciator with Remote Start/Stop and Remote Transfer | EA | 100 | $0.00 | ||
| FFP | X124 | Reserved | |||||
| Ancillary Services | |||||||
| X125 | Engine Generator Start-Up Service | ||||||
| FFP | X125A | Diesel EG Start-up regular work hours; Monday-Friday | EA | 196 | $0.00 | ||
| FFP | X125B | Propane EG Start-up regular work hours; Monday-Friday | EA | 45 | $0.00 | ||
| FFP | X125C | Diesel EG Start-up after regular work hours, includes weekend | EA | 104 | $0.00 | ||
| FFP | X125D | Propane EG Start-up after regular work hours, includes weekend | EA | 50 | $0.00 | ||
| FFP | X125E | ATS Start-up regular works hours; Monday-Friday | EA | 10 | $0.00 | ||
| FFP | X125F | ATS Start-up after regular work hours; includes weekend | EA | 10 | $0.00 | ||
| FFP | X125G | Towable EG Start-up regular work hours; Monday-Friday | EA | 120 | $0.00 | ||
| FFP | X125H | Towable EG Start-up after regular work hours, includes weekend | EA | 50 | $0.00 | ||
| X126 | Delivery Service | ||||||
| CR | X126A | CONUS Freight, Delivery and Off-loading | NTE | $1,288,770.00 | |||
| CR | X126B | OCONUS Freight, Delivery and Off-loading | NTE | $991,200.00 | |||
| X127 | Contractor Conducted Training | ||||||
| FFP | X127A | Contractor Facility Training Tuition (per student) | EA | 450 | $0.00 | ||
| FFP | X127B | Contractor Conducted On-Site Training Tuition (per site) | EA | 4 | $0.00 | ||
| CR | X127C | Instructor Travel and shipping of materials in support of CLIN X127B | EA | NTE | $10,000.00 | ||
| CR | X127D | Other Training as Requested: may include, virtual and/or remote type training. | EA | NTE | $23,600.00 | ||
| X128 | Training Development | ||||||
| FFP | X128A | Training Development for FAA via Independent Task Order | NTE | $316,262.80 | |||
| FFP | X128B | Computer Based Training | EA | 1 | $0.00 | ||
| X128C | Reserved | ||||||
| X128D | Reserved | ||||||
| X129 | Training Support | ||||||
| LH | X129A | Training Specialist | HR | 320 | $0.00 | ||
| LH | X129B | Course Developer | HR | 320 | $0.00 | ||
| X130 | Program Management(including Program Management Deliverables) | ||||||
| LH | X130A | Program Manager | HR | 3840 | $0.00 | ||
| LH | X130B | ACEPS Program Manager | HR | 3840 | $0.00 | ||
| LH | X130C | ACEPS Technical Advisor | HR | 3840 | $0.00 | ||
| LH | X130D | Technical Advisor | HR | 1920 | $0.00 | ||
| FFP | X130E | Pre-Deployment Warehouse Rent(24 months in a period, Est total includes multiple of 24) | SF | 100000 | $0.00 | ||
| X131 | Conferences and Meetings | ||||||
| LH | X131A | Technical Support | HR | 40 | $0.00 | ||
| LH | X131B | Administrative Support | HR | 16 | $0.00 | ||
| X132 | Logistics Support & Program Management | ||||||
| LH | X132A | Logistics Program Manager | HR | 3840 | $0.00 | ||
| CR | X132B | Parts in support of the Contractor Depot Logistics Support (CDLS), Invoicing and Shipping P1, P2, and P5 | NTE | $1,882,829.88 | |||
| X133 | Reserved | ||||||
| X134 | Reserved | ||||||
| X135 | Reserved | ||||||
| X136 | Travel & Subsistence Support. Travel must be accomplished IAW the FAA's Travel Policy. | ||||||
| CR | X136A | Travel Support | EA | NTE | $24,337.50 | ||
| CR | X136B | Subsistence Support (Per Diem) | EA | NTE | $8,112.50 | ||
| X137 | Reserved | ||||||
| Special Engineering and Equipment | |||||||
| X138 | Extended Run (Prime Power) Engine Generator Modification Kits | ||||||
| FFP | X138A | 10 - 50 kW EG Modification | EA | 4 | $0.00 | ||
| FFP | X138B | 125 kW EG Modification | EA | 4 | $0.00 | ||
| FFP | X138C | 170 - 180 kW EG Modification | EA | 4 | $0.00 | ||
| CR | X139 | Engine Generator Engineering and Equipment for Special Applications. | NTE | $247,800.00 | |||
| X140 | Engine Generator Weather Enclosure | ||||||
| FFP | X140A | 20-30kW, Standard Enclosure | EA | 20 | $0.00 | ||
| FFP | X140B | 20-30kW, Coastal Enclosure | EA | 5 | $0.00 | ||
| FFP | X140C | 20-30kW, Cold Weather Enclosure | EA | 20 | $0.00 | ||
| FFP | X140D | 100kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140E | 100kW, Coastal Enclosure | EA | 5 | $0.00 | ||
| FFP | X140F | 100kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| FFP | X140G | 125kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140H | 125kW, Coastal Enclosure | EA | 10 | $0.00 | ||
| FFP | X140I | 125kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| FFP | X140J | 180-200 kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140K | 180-200 kW, Coastal Enclosure | EA | 10 | $0.00 | ||
| FFP | X140L | 180-200 kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| CR | X140M | All other sizes/fuel type, Standard Enclosure | EA | NTE | $2,360,000.00 | ||
| CR | X140N | All other sizes/fuel type, Coastal Enclosure | EA | NTE | $1,180,000.00 | ||
| CR | X140O | All other sizes/fuel type, Cold Weather Enclosure | EA | NTE | $2,360,000.00 | ||
| X141 | Sub-Base Tanks | ||||||
| FFP | X141A | 126 Gal, UL-142 sub-base tank with platforms (sized based on 20-30kW EG) | EA | 15 | $0.00 | ||
| FFP | X141B | 126 Gal, UL-2085 sub-base tank with platforms (sized based on 20-30kW EG) | EA | 30 | $0.00 | ||
| FFP | X141C | 476 Gal, UL-142 sub-base tank with platforms (sized based on 100kW EG) | EA | 30 | $0.00 | ||
| FFP | X141D | 476 Gal, UL-2085 sub-base tank with platforms (sized based on 100kW EG) | EA | 25 | $0.00 | ||
| FFP | X141E | 548 Gal, UL-142 sub-base tank with platforms (sized based on 125kW EG) | EA | 30 | $0.00 | ||
| FFP | X141F | 548 Gal, UL-2085 sub-base tank with platforms (sized based on 125kW EG) | EA | 25 | $0.00 | ||
| FFP | X141G | 821 Gal, UL-142 sub-base tank with platforms (sized based on 180-200kW EG) | EA | 35 | $0.00 | ||
| FFP | X141H | 821 Gal, UL-2085 sub-base tank with platforms (sized based on 180-200kW EG) | EA | 20 | $0.00 | ||
| CR | X141I | UL-142 sub-base tank with platforms (general size) | EA | NTE | $590,000.00 | ||
| CR | X141J | UL-2085 sub-base tank with platforms (general size) | EA | NTE | $885,000.00 | ||
| Engine Generator Set (EGS) First Article Testing | |||||||
| X142 | Test Engine Generator Sets | ||||||
| FFP | X142A | Stationary, Industrial, Propane Spark Ignited, EGS, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142B | Stationary, Industrial, Diesel EGS, 10 kW to 200 kW, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142C | Stationary, Industrial, Diesel EGS, 250 kW to 500 kW, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142D | Stationary, Industrial, Diesel EGS, 600 kW to 1,500 kW, with Load Bank | EA | 1 | $0.00 | ||
| Miscellaneous | |||||||
| X143 | Portable Load Banks | ||||||
| FFP | X143A | Portable Load Bank, 75kW (1kW or 5kW resolution) 208v, three phase, 20' Load Cable Set (and Ground cable) with Mating Connectors (on phase cables) and Lugs (on Ground cable) | EA | 128 | $0.00 | ||
| FFP | X143B | Portable Load Bank, 75kW (1kW or 5kW resolution) 240v, single phase, 20' Load Cable Set (and Ground cable) with Mating Connectors (on phase cables) and Lugs (on Ground cable) | EA | 52 | $0.00 | ||
| X144 | Service and Non-Warranty Support | ||||||
| CR | X144A | Non-Warranty Repair of Engine Generator Equipment or Technical Assistance/Troubleshooting | NTE | $413,000.00 | |||
| FFP | X145 | Engine Start Integrity Module - Automatic Transfer Switch - IAW: NEC (2020) Art 695 “Fire Pumps”, para 695.14(F), ; and NEC (2020) Art 700 “Emergency Systems”, para 700.10(D)(4). | EA | 10 | $0.00 | ||
| FFP | X146 | Engine Start Integrity Module - EG - IAW: NEC (2020) Art 695 “Fire Pumps”, para 695.14(F), ; and NEC (2020) Art 700 “Emergency Systems”, para 700.10(D)(4).- | EA | 10 | $0.00 | ||
| X147 | PSG and Non-PSG Equipment Service Hours and Travel | ||||||
| LH | X147A | PSG Equipment Service Hours | HR | 1500 | $0.00 | ||
| LH | X147B | Non-PSG Equipment Service Hours | HR | 10 | $0.00 | ||
| CR | X147C | PSG and Non-PSG Equipment Service Travel | NTE | NTE | $80,000.00 | ||
| ACEPS & TRACON Specific CLINS | |||||||
| X148 | Temporary Systems | ||||||
| FFP | X148A | STANDBY Temp Trailer System - Controls only, for SA/SB Standby lineups and controls supporting three (3) EG trailer modules. Standard factory testing. (1 nos. per temporary ACEPS power system) Order 1 CLIN per complete temporary system. FAA to match these controls to standby system of their choice. | |||||
| Optional: Witness Testing Available | EA | 1 | $0.00 | ||||
| FFP | X148B | STANDBY Temp Trailer System - Standby and Controls, includes SA/SB Standby lineups and controls that support three (3) EG trailer modules. |
Standard factory testing. (1 nos. per temporary ACEPS power system) Order 1 CLIN per complete temporary system.
| Optional: Witness Testing Available | EA | 2 | $0.00 | |||
| X149 | ARTCC | |||||
| FFP | X149A | Phase 2 Permanent STANDBY System Complete with Standard factory testing, sectional SA/SB lineups and controls - Supports 4 nos. of 1500kW generators (1 Standby system per ACEPS Site) Order 1 CLIN per site. | ||||
| Optional: Witness Testing Available | EA | 2 | $0.00 | |||
| X150 | TRACON | |||||
| FFP | X150A | Phase 2 Tracon Permanent STANDBY System - Systems and Controls Only. Complete with Standard factory testing, sectional SA/SB lineups and controls. Supports Tracon or 1000KW generators (1 Standby system per Tracon Site) Order 1 CLIN Per site. Optional: Witness Testing Available | EA | 0 | $0.00 | |
| FFP | X150B | Phase 2 Tracon Permanent STANDBY System - 800A ATS; 2 nos. 800A ATS needed to support Tracon or generators. Order 2 CLIN Per site | EA | 0 | $0.00 | |
| FFP | X150C | Phase 2 Tracon Permanent STANDBY System - 2000A ATS; 2 nos. 2000A ATS - Supports Tracon or generators. Order 2 CLIN Per site | EA | 0 | $0.00 | |
| X152 | Logistics Support (ACEPS specific) | |||||
| FFP | X152A | STANDBY Temp Trailer - Site Spares List | EA | 1 | $0.00 | |
| FFP | X152B | STANDBY Temp Trailer - CDLS Spares List | EA | 1 | $0.00 | |
| FFP | X152C | Phase 2 Perm STANDBY - Site Spares List | EA | 2 | $0.00 | |
| FFP | X152D | Phase 2 Perm STANDBY - CDLS Spares List (1 time stocking of CDLS) | EA | 1 | $0.00 | |
| FFP | X152E | Phase 2 Perm STANDBY - Support Equipment Candidate List (SECL) | EA | 1 | $0.00 | |
| FFP | X152F | EG Perm System - Site Spares List -1500kW | EA | 1 | $0.00 | |
| FFP | X152G | EG Perm System - Site Spares List - 1250kW | EA | 1 | $0.00 | |
| FFP | X152H | EG Perm System - CDLS Spares List - 1500kW (1 time stock for 5 sites - 20 gens) | EA | 1 | $0.00 | |
| FFP | X152I | EG Perm System - CDLS Spares List - 1250kW (1 time stock for 5 sites - 20 gens) | EA | 1 | $0.00 | |
| FFP | X152J | EG Perm System - Support Equipment Candidate List (SECL) | EA | 1 | $0.00 | |
| FFP | X152K | EG Tracon Perm System - Site Spares List - 1000kW | EA | 0 | $0.00 | |
| FFP | X152L | EG Tracon Perm System - CDLS Spares List (1 time stocking of CDLS) | EA | 0 | $0.00 | |
| FFP | X152M | Phase 2 Tracon Perm STANDBY - Site Spares List | EA | 0 | $0.00 | |
| FFP | X152N | Phase 2 Tracon Perm STANDBY - CDLS Spares List | EA | 0 | $0.00 | |
| ACEPS EQUIPMENT SERVICE HOURS, TRAVEL, PARTS, MATERIALS & EQUIPMENT | ||||||
| FFP | X153 | ACEP Equipment Service Hours | HR | 1500 | $0.00 | |
| FFP | X154 | ACEP Equipment Service Parts,Materials and Equipment | NTE | NTE | $260,000.00 | |
| CR | X155 | ACEPS Equipment Service Travel | NTE | NTE | $80,000.00 | |
| Total Base Period: | $13,354,912.68 |
EG NS B.1 Pricing Attachment
Option One
| Pricing | CLIN | ITEM | Unit | Option One Period | |||
| Est. Qty | Price Per Unit | Est. Total | |||||
| EQUIPMENT/ HARDWARE | |||||||
| X101 | Stationary Generator, Industrial, Diesel 277/480 Volt, 3 Phase, Wye, 4 Wire, 100 kW to 1,500 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X101A | 100 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101B | 125 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101C | 150 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101D | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101E | 200 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101F | 250 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101G | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101H | 400 kW Generator: Rail Mounted Radiator | EA | 5 | $0.00 | ||
| FFP | X101HA | 400 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101I | 500 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101IA | 500 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101J | 600 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101JA | 600 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101K | 750 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101KA | 750 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101L | 800 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101LA | 800 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101M | 1,000 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101MA | 1,000 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101N | 1,250 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101NA | 1,250 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101O | 1,500 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101OA | 1,500 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| X102 | Stationary Generator, Industrial, Diesel 120/208 Volt, 3 Phase, Wye, 4 Wire, 10 kW to 300 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X102A | 10 - 15 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X102B | 20 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102C | 30 - 35 kW Generator: Rail Mounted Radiator | EA | 18 | $0.00 | ||
| FFP | X102D | 50 kW Generator: Rail Mounted Radiator | EA | 17 | $0.00 | ||
| FFP | X102E | 80 kW Generator: Rail Mounted Radiator | EA | 7 | $0.00 | ||
| FFP | X102F | 100 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X102G | 125 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102H | 150 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102I | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 30 | $0.00 | ||
| FFP | X102J | 200 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102K | 250 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X102L | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| X103 | Stationary Generator, Industrial, Diesel 120/240 Volt, 3 Phase, Delta, 4 Wire. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X103A | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| X104 | Stationary Generator, Industrial, Diesel 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X104A | 10 - 15 kW | EA | 1 | $0.00 | ||
| FFP | X104B | 20 kW | EA | 10 | $0.00 | ||
| FFP | X104C | 30 - 35 kW | EA | 10 | $0.00 | ||
| FFP | X104D | 50 kW | EA | 5 | $0.00 | ||
| X105 | Stationary Generator, Industrial, Propane 120/208 Volt, 3 Phase, Wye, 4 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X105A | 10 -15 kW | EA | 1 | $0.00 | ||
| FFP | X105B | 25 kW | EA | 10 | $0.00 | ||
| FFP | X105C | 39 - 49 kW | EA | 35 | $0.00 | ||
| FFP | X105D | 50 - 60 kW | EA | 3 | $0.00 | ||
| FFP | X105E | 100 kW | EA | 7 | $0.00 | ||
| FFP | X105F | 125 kW | EA | 5 | $0.00 | ||
| FFP | X105G | 150 kW | EA | 5 | $0.00 | ||
| X106 | Stationary Generator, Industrial, Propane 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X106A | 10 - 20 kW | EA | 1 | $0.00 | ||
| FFP | X106B | 25 - 44 kW | EA | 18 | $0.00 | ||
| FFP | X106C | 50 - 60 kW | EA | 7 | $0.00 | ||
| FFP | X106D | 100 kW | EA | 1 | $0.00 | ||
| X107 | Towable Generator, Industrial, Diesel, Multiple Voltage Configurations Switchable to: 120/208v 3 phase, or 120/240v single phase, or 277/480v 3 phase | ||||||
| FFP | X107A | 20 - 29 kW | EA | 60 | $0.00 | ||
| FFP | X107B | 50 - 60 kW | EA | 30 | $0.00 | ||
| FFP | X107C | 100 kW | EA | 10 | $0.00 | ||
| FFP | X107D | 150 kW | EA | 10 | $0.00 | ||
| FFP | X107E | 200 kW | EA | 10 | $0.00 | ||
| X108 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X108A | 150 AMP | EA | 2 | $0.00 | ||
| FFP | X108B | 260 AMP | EA | 8 | $0.00 | ||
| FFP | X108C | 400 AMP | EA | 25 | $0.00 | ||
| FFP | X108D | 600 AMP | EA | 6 | $0.00 | ||
| FFP | X108E | 800 AMP | EA | 10 | $0.00 | ||
| FFP | X108F | 1,000 AMP | EA | 6 | $0.00 | ||
| FFP | X108G | 1,200 AMP | EA | 5 | $0.00 | ||
| FFP | X108H | 1,600 AMP | EA | 3 | $0.00 | ||
| FFP | X108I | 2,000 AMP | EA | 1 | $0.00 | ||
| FFP | X108J | 2,600 AMP | EA | 1 | $0.00 | ||
| X109 | Portable, Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X109A | 150A | EA | 20 | $0.00 | ||
| FFP | X109B | 260A | EA | 15 | $0.00 | ||
| FFP | X109C | 400A | EA | 10 | $0.00 | ||
| FFP | X109D | 600A | EA | 5 | $0.00 | ||
| FFP | X109E | 800A | EA | 5 | $0.00 | ||
| X110 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X110A | 150 AMP | EA | 0 | $0.00 | ||
| FFP | X110B | 260 AMP | EA | 0 | $0.00 | ||
| FFP | X110C | 400 AMP | EA | 0 | $0.00 | ||
| FFP | X110D | 600 AMP | EA | 0 | $0.00 | ||
| FFP | X110E | 800 AMP | EA | 0 | $0.00 | ||
| FFP | X110F | 1,000 AMP | EA | 0 | $0.00 | ||
| FFP | X110G | 1,200 AMP | EA | 0 | $0.00 | ||
| FFP | X110H | 1,600 AMP | EA | 0 | $0.00 | ||
| FFP | X110I | 2,000 AMP | EA | 0 | $0.00 | ||
| FFP | X110J | 2,600 AMP | EA | 0 | $0.00 | ||
| X111 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X111A | 150 AMP | EA | 35 | $0.00 | ||
| FFP | X111B | 260 AMP | EA | 60 | $0.00 | ||
| FFP | X111C | 400 AMP | EA | 20 | $0.00 | ||
| FFP | X111D | 600 AMP | EA | 31 | $0.00 | ||
| FFP | X111E | 800 AMP | EA | 36 | $0.00 | ||
| FFP | X111F | 1,000 AMP | EA | 16 | $0.00 | ||
| FFP | X111G | 1,200 AMP | EA | 2 | $0.00 | ||
| X112 | Portable Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X112A | 150A | EA | 45 | $0.00 | ||
| FFP | X112B | 260A | EA | 45 | $0.00 | ||
| FFP | X112C | 400A | EA | 45 | $0.00 | ||
| FFP | X112D | 600A | EA | 35 | $0.00 | ||
| FFP | X112E | 800A | EA | 10 | $0.00 | ||
| X113 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X113A | 150 AMP | EA | 0 | $0.00 | ||
| FFP | X113B | 260 AMP | EA | 0 | $0.00 | ||
| FFP | X113C | 400 AMP | EA | 0 | $0.00 | ||
| FFP | X113D | 600 AMP | EA | 0 | $0.00 | ||
| FFP | X113E | 800 AMP | EA | 0 | $0.00 | ||
| FFP | X113F | 1,000 AMP | EA | 0 | $0.00 | ||
| FFP | X113G | 1,200 AMP | EA | 0 | $0.00 | ||
| FFP | X114 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Open Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 1 | $0.00 | ||
| FFP | X115 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Closed Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 0 | $0.00 | ||
| X116 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X116A | 150 Amp | EA | 18 | $0.00 | ||
| FFP | X116B | 260 Amp | EA | 25 | $0.00 | ||
| FFP | X116C | 400 Amp | EA | 8 | $0.00 | ||
| X117 | Portable Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X117A | 150A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117B | 260A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117C | 400A Open Trans Portable ATS, 240V | EA | 5 | $0.00 | ||
| X118 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X118A | 150 Amp | EA | 0 | $0.00 | ||
| FFP | X118B | 260 Amp | EA | 0 | $0.00 | ||
| FFP | X118C | 400 Amp | EA | 0 | $0.00 | ||
| X119 | X119 | Day Tank, Fill pump, Reverse pump, Secondary containment | |||||
| FFP | X119A | Size: 10 Gal | EA | 26 | $0.00 | ||
| FFP | X119B | Size: 25 Gal | EA | 75 | $0.00 | ||
| FFP | X119C | Size: 50 Gal | EA | 68 | $0.00 | ||
| FFP | X119D | Size: 60 Gal | EA | 60 | $0.00 | ||
| FFP | X119E | Size: 75 Gal | EA | 41 | $0.00 | ||
| FFP | X119F | Size: 100 Gal | EA | 0 | $0.00 | ||
| FFP | X119G | Size: 150 Gal | EA | 0 | $0.00 | ||
| FFP | X119H | Size: 275 Gal | EA | 0 | $0.00 | ||
| FFP | X119I | Size: 300 Gal | EA | 0 | $0.00 | ||
| FFP | X119J | Size: 500 Gal | EA | 0 | $0.00 | ||
| X120 | Remote Load Banks, Balanced Resistive Load | ||||||
| FFP | X120A | 100kW, 208V, 3Ø | EA | 25 | $0.00 | ||
| FFP | X120B | 100kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120C | 150kW, 208V, 3Ø | EA | 30 | $0.00 | ||
| FFP | X120D | 150kW, 240V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120E | 150kW, 480V, 3Ø | EA | 20 | $0.00 | ||
| FFP | X120F | 200kW, 208V, 3Ø | EA | 10 | $0.00 | ||
| FFP | X120G | 200kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120H | 250kW, 208V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120I | 250kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120J | 300kW, 480V, 3Ø | EA | 5 | $0.00 | ||
| FFP | X120K | 350kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120L | 400kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120M | 500kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120N | 600kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120O | 750kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120P | 800kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120Q | 1000kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120R | 1250kW, 480V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120S | 1500kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| X121 | Silencer / Muffler | ||||||
| FFP | X121A | Silencer, Industrial for CLIN X104A | EA | 150 | $0.00 | ||
| FFP | X121B | Silencer, Critical for CLIN X104A | EA | 1 | $0.00 | ||
| FFP | X121C | Silencer, Industrial for CLIN X104D | EA | 70 | $0.00 | ||
| FFP | X121D | Silencer, Critical for CLIN X104D | EA | 1 | $0.00 | ||
| FFP | X121E | Silencer, Residential for CLINs X102G & X102GA | EA | 130 | $0.00 | ||
| FFP | X121F | Silencer, Critical for CLINs X102G & X102GA | EA | 4 | $0.00 | ||
| FFP | X121G | Silencer, Residential for CLINs X101G & X101GA | EA | 9 | $0.00 | ||
| FFP | X121H | Silencer, Critical for CLINs X101G & X101GA | EA | 2 | $0.00 | ||
| FFP | X121I | Silencer, Residential for CLINs X101I & X101IA | EA | 3 | $0.00 | ||
| FFP | X121J | Silencer, Critical for CLINs X101I & X101IA | EA | 2 | $0.00 | ||
| FFP | X121K | Silencer, Residential for CLINs X101L & X101LA | EA | 3 | $0.00 | ||
| FFP | X121L | Silencer, Critical for CLINs X101L & X101LA | EA | 1 | $0.00 | ||
| FFP | X121M | Silencer, Residential for CLINs X101M & X101MA | EA | 1 | $0.00 | ||
| FFP | X121N | Silencer, Critical for CLINs X101M & X101MA | EA | 3 | $0.00 | ||
| FFP | X121O | Silencer, Critical for CLINs X101M, X101MA, X101N, & X101NA | EA | 1 | $0.00 | ||
| FFP | X121P | Silencer, Hospital for CLINs X101M, X101MA, X101N, & X101NA | EA | 1 | $0.00 | ||
| CR | X122 | Radiator, Remote - price based on site specific configuration. May be horizontal or vertical, stainless steel or aluminum. | EA | NTE | $371,700.00 | ||
| FFP | X123 | Remote Annunciator with Remote Start/Stop and Remote Transfer | EA | 100 | $0.00 | ||
| FFP | X124 | Reserved | |||||
| Ancillary Services | |||||||
| X125 | Engine Generator Start-Up Service | ||||||
| FFP | X125A | Diesel EG Start-up regular work hours; Monday-Friday | EA | 196 | $0.00 | ||
| FFP | X125B | Propane EG Start-up regular work hours; Monday-Friday | EA | 45 | $0.00 | ||
| FFP | X125C | Diesel EG Start-up after regular work hours, includes weekend | EA | 104 | $0.00 | ||
| FFP | X125D | Propane EG Start-up after regular work hours, includes weekend | EA | 50 | $0.00 | ||
| FFP | X125E | ATS Start-up regular works hours; Monday-Friday | EA | 10 | $0.00 | ||
| FFP | X125F | ATS Start-up after regular work hours; includes weekend | EA | 10 | $0.00 | ||
| FFP | X125G | Towable EG Start-up regular work hours; Monday-Friday | EA | 120 | $0.00 | ||
| FFP | X125H | Towable EG Start-up after regular work hours, includes weekend | EA | 50 | $0.00 | ||
| X126 | Delivery Service | ||||||
| CR | X126A | CONUS Freight, Delivery and Off-loading | NTE | $1,339,883.50 | |||
| CR | X126B | OCONUS Freight, Delivery and Off-loading | NTE | $1,040,760.00 | |||
| X127 | Contractor Conducted Training | ||||||
| FFP | X127A | Contractor Facility Training Tuition (per student) | EA | 450 | $0.00 | ||
| FFP | X127B | Contractor Conducted On-Site Training Tuition (per site) | EA | 4 | $0.00 | ||
| CR | X127C | Instructor Travel and shipping of materials in support of CLIN X127B | EA | NTE | $10,500.00 | ||
| CR | X127D | Other Training as Requested: may include, virtual and/or remote type training. | EA | NTE | $24,780.00 | ||
| X128 | Training Development | ||||||
| FFP | X128A | Training Development for FAA via Independent Task Order | NTE | $442,767.92 | |||
| FFP | X128B | Computer Based Training | EA | ||||
| X128C | Reserved | ||||||
| X128D | Reserved | ||||||
| X129 | Training Support | ||||||
| LH | X129A | Training Specialist | HR | 40 | $0.00 | ||
| LH | X129B | Course Developer | HR | 40 | $0.00 | ||
| X130 | Program Management(including Program Management Deliverables) | ||||||
| LH | X130A | Program Manager | HR | 3840 | $0.00 | ||
| LH | X130B | ACEPS Program Manager | HR | 3840 | $0.00 | ||
| LH | X130C | ACEPS Technical Advisor | HR | 3840 | $0.00 | ||
| LH | X130D | Technical Advisor | HR | 1920 | $0.00 | ||
| FFP | X130E | Pre-Deployment Warehouse Rent(24 months in a period, Est total includes multiple of 24) | SF | 100000 | $0.00 | ||
| X131 | Conferences and Meetings | ||||||
| LH | X131A | Technical Support | HR | 40 | $0.00 | ||
| LH | X131B | Administrative Support | HR | 16 | $0.00 | ||
| X132 | Logistics Support & Program Management | ||||||
| LH | X132A | Logistics Program Manager | HR | 3860 | $0.00 | ||
| CR | X132B | Parts in support of the Contractor Depot Logistics Support (CDLS), Invoicing and Shipping P1, P2, and P5 | NTE | $1,976,971.37 | |||
| X133 | Reserved | ||||||
| X134 | Reserved | ||||||
| X135 | Reserved | ||||||
| X136 | Travel & Subsistence Support. Travel must be accomplished IAW the FAA's Travel Policy. | ||||||
| CR | X136A | Travel Support | EA | $25,554.38 | |||
| CR | X136B | Subsistence Support (Per Diem) | EA | $8,518.13 | |||
| X137 | Reserved | ||||||
| Special Engineering and Equipment | |||||||
| X138 | Extended Run (Prime Power) Engine Generator Modification Kits | ||||||
| FFP | X138A | 10 - 50 kW EG Modification | EA | 4 | $0.00 | ||
| FFP | X138B | 125 kW EG Modification | EA | 4 | $0.00 | ||
| FFP | X138C | 170 - 180 kW EG Modification | EA | 4 | $0.00 | ||
| CR | X139 | Engine Generator Engineering and Equipment for Special Applications. | NTE | $260,190.00 | |||
| X140 | Engine Generator Weather Enclosure | ||||||
| FFP | X140A | 20-30kW, Standard Enclosure | EA | 20 | $0.00 | ||
| FFP | X140B | 20-30kW, Coastal Enclosure | EA | 5 | $0.00 | ||
| FFP | X140C | 20-30kW, Cold Weather Enclosure | EA | 20 | $0.00 | ||
| FFP | X140D | 100kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140E | 100kW, Coastal Enclosure | EA | 5 | $0.00 | ||
| FFP | X140F | 100kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| FFP | X140G | 125kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140H | 125kW, Coastal Enclosure | EA | 10 | $0.00 | ||
| FFP | X140I | 125kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| FFP | X140J | 180-200 kW, Standard Enclosure | EA | 25 | $0.00 | ||
| FFP | X140K | 180-200 kW, Coastal Enclosure | EA | 10 | $0.00 | ||
| FFP | X140L | 180-200 kW, Cold Weather Enclosure | EA | 25 | $0.00 | ||
| CR | X140M | All other sizes/fuel type, Standard Enclosure | EA | NTE | $2,478,000.00 | ||
| CR | X140N | All other sizes/fuel type, Coastal Enclosure | EA | NTE | $1,239,000.00 | ||
| CR | X140O | All other sizes/fuel type, Cold Weather Enclosure | EA | NTE | $2,478,000.00 | ||
| X141 | Sub-Base Tanks | ||||||
| FFP | X141A | 126 Gal, UL-142 sub-base tank with platforms (sized based on 20-30kW EG) | EA | 15 | $0.00 | ||
| FFP | X141B | 126 Gal, UL-2085 sub-base tank with platforms (sized based on 20-30kW EG) | EA | 30 | $0.00 | ||
| FFP | X141C | 476 Gal, UL-142 sub-base tank with platforms (sized based on 100kW EG) | EA | 30 | $0.00 | ||
| FFP | X141D | 476 Gal, UL-2085 sub-base tank with platforms (sized based on 100kW EG) | EA | 25 | $0.00 | ||
| FFP | X141E | 548 Gal, UL-142 sub-base tank with platforms (sized based on 125kW EG) | EA | 30 | $0.00 | ||
| FFP | X141F | 548 Gal, UL-2085 sub-base tank with platforms (sized based on 125kW EG) | EA | 25 | $0.00 | ||
| FFP | X141G | 821 Gal, UL-142 sub-base tank with platforms (sized based on 180-200kW EG) | EA | 35 | $0.00 | ||
| FFP | X141H | 821 Gal, UL-2085 sub-base tank with platforms (sized based on 180-200kW EG) | EA | 20 | $0.00 | ||
| CR | X141I | UL-142 sub-base tank with platforms (general size) | EA | NTE | $619,500.00 | ||
| CR | X141J | UL-2085 sub-base tank with platforms (general size) | EA | NTE | $929,250.00 | ||
| Engine Generator Set (EGS) First Article Testing | |||||||
| X142 | Test Engine Generator Sets | ||||||
| FFP | X142A | Stationary, Industrial, Propane Spark Ignited, EGS, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142B | Stationary, Industrial, Diesel EGS, 10 kW to 200 kW, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142C | Stationary, Industrial, Diesel EGS, 250 kW to 500 kW, with Load Bank | EA | 1 | $0.00 | ||
| FFP | X142D | Stationary, Industrial, Diesel EGS, 600 kW to 1,500 kW, with Load Bank | EA | 1 | $0.00 | ||
| Miscellaneous | |||||||
| X143 | Portable Load Banks | ||||||
| FFP | X143A | Portable Load Bank, 75kW (1kW or 5kW resolution) 208v, three phase, 20' Load Cable Set (and Ground cable) with Mating Connectors (on phase cables) and Lugs (on Ground cable) | EA | 128 | $0.00 | ||
| FFP | X143B | Portable Load Bank, 75kW (1kW or 5kW resolution) 240v, single phase, 20' Load Cable Set (and Ground cable) with Mating Connectors (on phase cables) and Lugs (on Ground cable) | EA | 52 | $0.00 | ||
| X144 | Service and Non-Warranty Support | ||||||
| CR | X144A | Non-Warranty Repair of Engine Generator Equipment or Technical Assistance/Troubleshooting | NTE | $433,650.00 | |||
| FFP | X145 | Engine Start Integrity Module - Automatic Transfer Switch - IAW: NEC (2020) Art 695 “Fire Pumps”, para 695.14(F), ; and NEC (2020) Art 700 “Emergency Systems”, para 700.10(D)(4). | EA | 10 | $0.00 | ||
| FFP | X146 | Engine Start Integrity Module - EG - IAW: NEC (2020) Art 695 “Fire Pumps”, para 695.14(F), ; and NEC (2020) Art 700 “Emergency Systems”, para 700.10(D)(4).- | EA | 10 | $0.00 | ||
| X147 | PSG and Non-PSG Equipment Service Hours and Travel | ||||||
| LH | X147A | PSG Equipment Service Hours | HR | 1000 | $0.00 | ||
| LH | X147B | Non-PSG Equipment Service Hours | HR | 10 | $0.00 | ||
| CR | X147C | PSG and Non-PSG Equipment Service Travel | NTE | NTE | $63,000.00 | ||
| ACEPS & TRACON Specific CLINS | |||||||
| X148 | Temporary Systems | ||||||
| FFP | X148A | STANDBY Temp Trailer System - Controls only, for SA/SB Standby lineups and controls supporting three (3) EG trailer modules. Standard factory testing. (1 nos. per temporary ACEPS power system) Order 1 CLIN per complete temporary system. FAA to match these controls to standby system of their choice. | |||||
| Optional: Witness Testing Available | EA | 0 | $0.00 | ||||
| FFP | X148B | STANDBY Temp Trailer System - Standby and Controls, includes SA/SB Standby lineups and controls that support three (3) EG trailer modules. |
Standard factory testing. (1 nos. per temporary ACEPS power system) Order 1 CLIN per complete temporary system.
| Optional: Witness Testing Available | EA | 0 | $0.00 | |||
| X149 | ARTCC | |||||
| FFP | X149A | Phase 2 Permanent STANDBY System Complete with Standard factory testing, sectional SA/SB lineups and controls - Supports 4 nos. of 1500kW generators (1 Standby system per ACEPS Site) Order 1 CLIN per site. | ||||
| Optional: Witness Testing Available | EA | 4 | $0.00 | |||
| X150 | TRACON | |||||
| FFP | X150A | Phase 2 Tracon Permanent STANDBY System - Systems and Controls Only. Complete with Standard factory testing, sectional SA/SB lineups and controls. Supports Tracon or 1000KW generators (1 Standby system per Tracon Site) Order 1 CLIN Per site. Optional: Witness Testing Available | EA | 1 | $0.00 | |
| FFP | X150B | Phase 2 Tracon Permanent STANDBY System - 800A ATS; 2 nos. 800A ATS needed to support Tracon or generators. Order 2 CLIN Per site | EA | 1 | $0.00 | |
| FFP | X150C | Phase 2 Tracon Permanent STANDBY System - 2000A ATS; 2 nos. 2000A ATS - Supports Tracon or generators. Order 2 CLIN Per site | EA | 1 | $0.00 | |
| X152 | Logistics Support (ACEPS specific) | |||||
| FFP | X152A | STANDBY Temp Trailer - Site Spares List | EA | 0 | $0.00 | |
| FFP | X152B | STANDBY Temp Trailer - CDLS Spares List | EA | 0 | $0.00 | |
| FFP | X152C | Phase 2 Perm STANDBY - Site Spares List | EA | 4 | $0.00 | |
| FFP | X152D | Phase 2 Perm STANDBY - CDLS Spares List (1 time stocking of CDLS) | EA | 1 | $0.00 | |
| FFP | X152E | Phase 2 Perm STANDBY - Support Equipment Candidate List (SECL) | EA | 1 | $0.00 | |
| FFP | X152F | EG Perm System - Site Spares List -1500kW | EA | 1 | $0.00 | |
| FFP | X152G | EG Perm System - Site Spares List - 1250kW | EA | 1 | $0.00 | |
| FFP | X152H | EG Perm System - CDLS Spares List - 1500kW (1 time stock for 5 sites - 20 gens) | EA | 0 | $0.00 | |
| FFP | X152I | EG Perm System - CDLS Spares List - 1250kW (1 time stock for 5 sites - 20 gens) | EA | 0 | $0.00 | |
| FFP | X152J | EG Perm System - Support Equipment Candidate List (SECL) | EA | 1 | $0.00 | |
| FFP | X152K | EG Tracon Perm System - Site Spares List - 1000kW | EA | 1 | $0.00 | |
| FFP | X152L | EG Tracon Perm System - CDLS Spares List (1 time stocking of CDLS) | EA | 1 | $0.00 | |
| FFP | X152M | Phase 2 Tracon Perm STANDBY - Site Spares List | EA | 1 | $0.00 | |
| FFP | X152N | Phase 2 Tracon Perm STANDBY - CDLS Spares List | EA | 1 | $0.00 | |
| ACEPS EQUIPMENT SERVICE HOURS, TRAVEL, PARTS, MATERIALS & EQUIPMENT | ||||||
| FFP | X153 | ACEP Equipment Service Hours | HR | 1000 | $0.00 | |
| FFP | X154 | ACEP Equipment Service Parts,Materials and Equipment | NTE | NTE | $273,000.00 | |
| CR | X155 | ACEPS Equipment Service Travel | NTE | NTE | $63,000.00 | |
| Total Option One: | $14,078,025.29 |
EG NS B.1 Pricing Attachment
Option Two
| Pricing | CLIN | ITEM | Unit | Option Two Period | |||
| Est. Qty | Price Per Unit | Est. Total | |||||
| EQUIPMENT/ HARDWARE | |||||||
| X101 | Stationary Generator, Industrial, Diesel 277/480 Volt, 3 Phase, Wye, 4 Wire, 100 kW to 1,500 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X101A | 100 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101B | 125 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101C | 150 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101D | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X101E | 200 kW Generator: Rail Mounted Radiator | EA | 6 | $0.00 | ||
| FFP | X101F | 250 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101G | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101H | 400 kW Generator: Rail Mounted Radiator | EA | 5 | $0.00 | ||
| FFP | X101HA | 400 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101I | 500 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| FFP | X101IA | 500 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101J | 600 kW Generator: Rail Mounted Radiator | EA | 3 | $0.00 | ||
| FFP | X101JA | 600 kW Generator: Remote Radiator | EA | 3 | $0.00 | ||
| FFP | X101K | 750 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101KA | 750 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101L | 800 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101LA | 800 kW Generator: Remote Radiator | EA | 2 | $0.00 | ||
| FFP | X101M | 1,000 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X101MA | 1,000 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101N | 1,250 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101NA | 1,250 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| FFP | X101O | 1,500 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X101OA | 1,500 kW Generator: Remote Radiator | EA | 1 | $0.00 | ||
| X102 | Stationary Generator, Industrial, Diesel 120/208 Volt, 3 Phase, Wye, 4 Wire, 10 kW to 300 kW. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X102A | 10 - 15 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| FFP | X102B | 20 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102C | 30 - 35 kW Generator: Rail Mounted Radiator | EA | 18 | $0.00 | ||
| FFP | X102D | 50 kW Generator: Rail Mounted Radiator | EA | 17 | $0.00 | ||
| FFP | X102E | 80 kW Generator: Rail Mounted Radiator | EA | 7 | $0.00 | ||
| FFP | X102F | 100 kW Generator: Rail Mounted Radiator | EA | 20 | $0.00 | ||
| FFP | X102G | 125 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102H | 150 kW Generator: Rail Mounted Radiator | EA | 25 | $0.00 | ||
| FFP | X102I | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 30 | $0.00 | ||
| FFP | X102J | 200 kW Generator: Rail Mounted Radiator | EA | 10 | $0.00 | ||
| FFP | X102K | 250 kW Generator: Rail Mounted Radiator | EA | 2 | $0.00 | ||
| FFP | X102L | 300 kW Generator: Rail Mounted Radiator | EA | 4 | $0.00 | ||
| X103 | Stationary Generator, Industrial, Diesel 120/240 Volt, 3 Phase, Delta, 4 Wire. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X103A | 170 - 180 kW Generator: Rail Mounted Radiator | EA | 1 | $0.00 | ||
| X104 | Stationary Generator, Industrial, Diesel 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X104A | 10 - 15 kW | EA | 1 | $0.00 | ||
| FFP | X104B | 20 kW | EA | 10 | $0.00 | ||
| FFP | X104C | 30 - 35 kW | EA | 10 | $0.00 | ||
| FFP | X104D | 50 kW | EA | 5 | $0.00 | ||
| X105 | Stationary Generator, Industrial, Propane 120/208 Volt, 3 Phase, Wye, 4 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X105A | 10 -15 kW | EA | 1 | $0.00 | ||
| FFP | X105B | 25 kW | EA | 10 | $0.00 | ||
| FFP | X105C | 39 - 49 kW | EA | 35 | $0.00 | ||
| FFP | X105D | 50 - 60 kW | EA | 3 | $0.00 | ||
| FFP | X105E | 100 kW | EA | 7 | $0.00 | ||
| FFP | X105F | 125 kW | EA | 5 | $0.00 | ||
| FFP | X105G | 150 kW | EA | 5 | $0.00 | ||
| X106 | Stationary Generator, Industrial, Propane 120/240 Volt, 1 Phase, 3 Wire, Radiator: Rail Mounted. As detailed in Section J, Attachment J.01 | ||||||
| FFP | X106A | 10 - 20 kW | EA | 1 | $0.00 | ||
| FFP | X106B | 25 - 44 kW | EA | 18 | $0.00 | ||
| FFP | X106C | 50 - 60 kW | EA | 7 | $0.00 | ||
| FFP | X106D | 100 kW | EA | 1 | $0.00 | ||
| X107 | Towable Generator, Industrial, Diesel, Multiple Voltage Configurations Switchable to: 120/208v 3 phase, or 120/240v single phase, or 277/480v 3 phase | ||||||
| FFP | X107A | 20 - 29 kW | EA | 60 | $0.00 | ||
| FFP | X107B | 50 - 60 kW | EA | 30 | $0.00 | ||
| FFP | X107C | 100 kW | EA | 10 | $0.00 | ||
| FFP | X107D | 150 kW | EA | 10 | $0.00 | ||
| FFP | X107E | 200 kW | EA | 10 | $0.00 | ||
| X108 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X108A | 150 AMP | EA | 2 | $0.00 | ||
| FFP | X108B | 260 AMP | EA | 8 | $0.00 | ||
| FFP | X108C | 400 AMP | EA | 25 | $0.00 | ||
| FFP | X108D | 600 AMP | EA | 6 | $0.00 | ||
| FFP | X108E | 800 AMP | EA | 10 | $0.00 | ||
| FFP | X108F | 1,000 AMP | EA | 6 | $0.00 | ||
| FFP | X108G | 1,200 AMP | EA | 5 | $0.00 | ||
| FFP | X108H | 1,600 AMP | EA | 3 | $0.00 | ||
| FFP | X108I | 2,000 AMP | EA | 1 | $0.00 | ||
| FFP | X108J | 2,600 AMP | EA | 1 | $0.00 | ||
| X109 | Portable, Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X109A | 150A | EA | 20 | $0.00 | ||
| FFP | X109B | 260A | EA | 15 | $0.00 | ||
| FFP | X109C | 400A | EA | 10 | $0.00 | ||
| FFP | X109D | 600A | EA | 5 | $0.00 | ||
| FFP | X109E | 800A | EA | 5 | $0.00 | ||
| X110 | Automatic Transfer Switch (ATS) 277/480 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X110A | 150 AMP | EA | 0 | $0.00 | ||
| FFP | X110B | 260 AMP | EA | 0 | $0.00 | ||
| FFP | X110C | 400 AMP | EA | 0 | $0.00 | ||
| FFP | X110D | 600 AMP | EA | 0 | $0.00 | ||
| FFP | X110E | 800 AMP | EA | 0 | $0.00 | ||
| FFP | X110F | 1,000 AMP | EA | 0 | $0.00 | ||
| FFP | X110G | 1,200 AMP | EA | 0 | $0.00 | ||
| FFP | X110H | 1,600 AMP | EA | 0 | $0.00 | ||
| FFP | X110I | 2,000 AMP | EA | 0 | $0.00 | ||
| FFP | X110J | 2,600 AMP | EA | 0 | $0.00 | ||
| X111 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X111A | 150 AMP | EA | 35 | $0.00 | ||
| FFP | X111B | 260 AMP | EA | 60 | $0.00 | ||
| FFP | X111C | 400 AMP | EA | 20 | $0.00 | ||
| FFP | X111D | 600 AMP | EA | 31 | $0.00 | ||
| FFP | X111E | 800 AMP | EA | 36 | $0.00 | ||
| FFP | X111F | 1,000 AMP | EA | 16 | $0.00 | ||
| FFP | X111G | 1,200 AMP | EA | 2 | $0.00 | ||
| X112 | Portable Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X112A | 150A | EA | 45 | $0.00 | ||
| FFP | X112B | 260A | EA | 45 | $0.00 | ||
| FFP | X112C | 400A | EA | 45 | $0.00 | ||
| FFP | X112D | 600A | EA | 35 | $0.00 | ||
| FFP | X112E | 800A | EA | 10 | $0.00 | ||
| X113 | Automatic Transfer Switch (ATS) 120/208 Volt, 3 Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X113A | 150 AMP | EA | 0 | $0.00 | ||
| FFP | X113B | 260 AMP | EA | 0 | $0.00 | ||
| FFP | X113C | 400 AMP | EA | 0 | $0.00 | ||
| FFP | X113D | 600 AMP | EA | 0 | $0.00 | ||
| FFP | X113E | 800 AMP | EA | 0 | $0.00 | ||
| FFP | X113F | 1,000 AMP | EA | 0 | $0.00 | ||
| FFP | X113G | 1,200 AMP | EA | 0 | $0.00 | ||
| FFP | X114 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Open Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 1 | $0.00 | ||
| FFP | X115 | Automatic Transfer Switch (ATS) 120/240 Volt, 600 Amp, 3 Phase Delta ATS Closed Transition, with Bypass; Neutral: switching or overlapping, Supports CLINs X103A, X103AA, X106D, NEMA 1 | EA | 0 | $0.00 | ||
| X116 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X116A | 150 Amp | EA | 18 | $0.00 | ||
| FFP | X116B | 260 Amp | EA | 25 | $0.00 | ||
| FFP | X116C | 400 Amp | EA | 8 | $0.00 | ||
| X117 | Portable Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Open Transition, without Bypass, Neutral: switching or overlapping, NEMA 3 | ||||||
| FFP | X117A | 150A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117B | 260A Open Trans Portable ATS, 240V | EA | 45 | $0.00 | ||
| FFP | X117C | 400A Open Trans Portable ATS, 240V | EA | 5 | $0.00 | ||
| X118 | Automatic Transfer Switch (ATS) 120/240 Volt, Single Phase, ATS Closed Transition, with Bypass, Neutral: switching or overlapping, NEMA 1 | ||||||
| FFP | X118A | 150 Amp | EA | 0 | $0.00 | ||
| FFP | X118B | 260 Amp | EA | 0 | $0.00 | ||
| FFP | X118C | 400 Amp | EA | 0 | $0.00 | ||
| X119 | X119 | Day Tank, Fill pump, Reverse pump, Secondary containment | |||||
| FFP | X119A | Size: 10 Gal | EA | 26 | $0.00 | ||
| FFP | X119B | Size: 25 Gal | EA | 75 | $0.00 | ||
| FFP | X119C | Size: 50 Gal | EA | 68 | $0.00 | ||
| FFP | X119D | Size: 60 Gal | EA | 60 | $0.00 | ||
| FFP | X119E | Size: 75 Gal | EA | 41 | $0.00 | ||
| FFP | X119F | Size: 100 Gal | EA | 0 | $0.00 | ||
| FFP | X119G | Size: 150 Gal | EA | 0 | $0.00 | ||
| FFP | X119H | Size: 275 Gal | EA | 0 | $0.00 | ||
| FFP | X119I | Size: 300 Gal | EA | 0 | $0.00 | ||
| FFP | X119J | Size: 500 Gal | EA | 0 | $0.00 | ||
| X120 | Remote Load Banks, Balanced Resistive Load | ||||||
| FFP | X120A | 100kW, 208V, 3Ø | EA | 25 | $0.00 | ||
| FFP | X120B | 100kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120C | 150kW, 208V, 3Ø | EA | 30 | $0.00 | ||
| FFP | X120D | 150kW, 240V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120E | 150kW, 480V, 3Ø | EA | 20 | $0.00 | ||
| FFP | X120F | 200kW, 208V, 3Ø | EA | 10 | $0.00 | ||
| FFP | X120G | 200kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120H | 250kW, 208V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120I | 250kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120J | 300kW, 480V, 3Ø | EA | 5 | $0.00 | ||
| FFP | X120K | 350kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120L | 400kW, 480V, 3Ø | EA | 6 | $0.00 | ||
| FFP | X120M | 500kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120N | 600kW, 480V, 3Ø | EA | 3 | $0.00 | ||
| FFP | X120O | 750kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120P | 800kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120Q | 1000kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| FFP | X120R | 1250kW, 480V, 3Ø | EA | 1 | $0.00 | ||
| FFP | X120S | 1500kW, 480V, 3Ø | EA | 2 | $0.00 | ||
| X121 | Silencer / Muffler | ||||||
| FFP | X121A | Silencer, Industrial for CLIN X104A | EA | 150 | $0.00 | ||
| FFP | X121B | Silencer, Critical for CLIN X104A | EA | 1 | $0.00 | ||
| FFP | X121C | Silencer, Industrial for CLIN X104D | EA | 70 | $0.00 | ||
| FFP | X121D | Silencer, Critical for CLIN X104D | EA | 1 | $0.00 | ||
| FFP | X121E | Silencer, Residential for CLINs X102G & X102GA | EA | 130 | $0.00 | ||
| FFP | X121F | Silencer, Critical for CLINs X102G & X102GA | EA | 4 | $0.00 | ||
| FFP | X121G | Silencer, Residential for CLINs X101G & X101GA | EA | 9 | $0.00 | ||
| FFP | X121H | Silencer, Critical for CLINs X101G & X101GA | EA | 2 | $0.00 | ||
| FFP | X121I | Silencer, Residential for CLINs X101I & X101IA | EA | 3 | $0.00 | ||
| FFP | X121J | Silencer, Critical for CLINs X101I & X101IA | EA | 2 | $0.00 | ||
| FFP | X121K | Silencer, Residential for CLINs X101L & X101LA | EA | 3 | $0.00 | ||
| FFP | X121L | Silencer, Critical for CLINs X101L & X101LA | EA | 1 | $0.00 | ||
| FFP | X121M | Silencer, Residential for CLINs X101M & X101MA | EA | 1 | $0.00 | ||
| FFP | X121N | Silencer, Critical for CLINs X101M & X101MA | EA | 3 | $0.00 |