The file is an Excel spreadsheet detailing attic stock minimum requirements for the CMS Back on Campus-Phase 4 renovation project. The document specifies precise spare material quantities for various building components, including ceiling systems, acoustical panels, sound-absorbing wall units, carpet tiles, painting, toilet compartments, window shades, building management systems, wiring devices, luminaires, lighting controls, faucets, soap dispensers, and water filters.
Specific attic stock requirements include maintaining 2-5% of installed quantities for most materials, with precise component breakdowns such as three spare door hinges for toilet compartments, five spare wiring devices, one full-size roller window shade per type, five lamp replacements per 100 installed, and 30 extra water filters per refrigerator. These spare materials are to be packaged with protective covering, labeled with contents description, and held for potential future replacement or maintenance needs during the project's lifecycle.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| CMS Phase 4 Attic Stock Requirement | |
| Material | Description of Requirements |
| Beam and Baffle Ceiling System | 1. Ceiling Units: Full-size panels equal to 2 percent of quantity installed. |
2. Suspension-System Components: Quantity of each exposed component equal to 2 percent of quantity installed.
Acoustical Panel Ceilings 1. Acoustical Ceiling Units: Full-size panels equal to 2 percent of quantity installed.
2. Suspension-System Components: Quantity of each exposed component equal to 2 percent of quantity installed.
| Sound Absorbing Wall Units | Furnish extra materials ( 1 full panel per color) from same production run that match products installed and that are packaged with protective covering for storage and identified with labels describing the contents. |
| Tile Carpeting | Carpet Tile: Full-size units equal to 5 percent of amount installed for each type indicated, but not less than 10 sq. yd. |
| Interior Painting | Provide 1 gal for any non building standard colors. |
| Phenolic-Core Toilet Compartments | Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. |
1. Door Hinges: Three hinge(s) with associated fasteners.
2. Latch and Keeper: Three latch(es) and keeper(s) with associated fasteners.
3. Door Bumper: Three door bumper(s) with associated fasteners.
4. Door Pull: Three door pull(s) with associated fasteners.
5. Fasteners: Ten fasteners of each size and type.
| Roller Window Shades | Provide 1 full-size units for each size and type and minimum of 2 additional daylight sensors. |
| Building Management System | Provide three service kits for use by Owner's personnel in testing and making minor service adjustments to the system. Include as a minimum: |
1. All specialized nonstandard tools and adapters and fittings required for operating, maintaining, testing and adjustment of the system.
2. Lubricant required for automatic valves and automatic dampers, one year supply.
| Wiring Devices | Provide five (5) spare devices for each type used on the project |
| Luminaires and Accessories | A. Provide spare materials described below that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. Provide at least one (1) of each type. |
1. Lamps: Five (5) for every 100 of each type and rating installed. - (all lights on this job LED
2. Plastic Diffusers and Lenses: One (1) for every 100 of each type and rating installed.
3. Battery and Charger: One (1) for every 20 emergency lighting units installed.
4. Drivers: One (1) for every 100 of each type and rating installed.
5. Globes and Guards: One (1) for every 20 of each type and rating installed.
| Lighting Control Devices | Provide five (5) spare devices for each type used on the project. |
| Faucets | Provide one (1) faucet of each type installed. |
| Soap Dispensers | Request (3) full set of soap Dispenser |
| Water Filters | Request (30) extra Water filter for each refrigerator installed |