About this file

This is a Utility Plan for the City of Lancaster Operations Facility Expansion project located at 150 Pitney Road in Lancaster County, Pennsylvania, prepared by the City of Lancaster Department of Public Works in coordination with East Lampeter Township. The project encompasses utility infrastructure installation and coordination for a new operations facility, including water service lines, sanitary and stormwater drainage systems, gas service connections, electrical and communications conduits, and ancillary site utilities. The plan specifies proposed utility locations, connection points, and coordination requirements among multiple utility providers including the City of Lancaster Water Bureau, UGI Utilities for gas service, and PPL Electric Utilities. The General Contractor is responsible for all subgrade preparation, earthwork, trenching for utility lines, and coordination with utility providers. The plan includes multiple addenda issued between October 6, 2026, and October 29, 2026, indicating ongoing design refinements and clarifications for the project.

The Utility Plan establishes minimum vertical clearance requirements for utility separations, with stormwater, sanitary, and water lines requiring 18-inch separation from each other, gas and AV/IT systems requiring 12-inch separation from other utilities, and electrical systems subject to PPL requirements. The General Contractor must coordinate with UGI regarding gas service installation scheduling and provide necessary trenching, stone dust per UGI specifications, and a concrete pad for gas meter installation prior to meter installation by UGI. The electrical contractor is responsible for primary and secondary duct bank installation with trenching provided by the General Contractor, while PPL will perform cable pulling, transformer installation, and metering. The plan was scaled at 1 inch equals 30 feet and plotted on November 2, 2026, with project identification number 2025992-044.

View the file

Other files

File Type Posted
34-25061 - Addendum 3 Arch-struct-MEP summary.pdf PDF
3-C05 - Site Civil Specifications Combined.pdf PDF
15-2026-10-06 - ES Addendum 1.pdf PDF
35-25061 - Addendum 3 Arch-struct-MEP summary.pdf PDF
10-C08 - Construction Plan.pdf PDF
Demolition.dwg DWG drawing
17-323113 - CHAIN LINK FENCES AND GATES.pdf PDF
321723 - PAVEMENT MARKINGS.pdf PDF
6-C10 - Geotechnical Report.pdf PDF
42-312000 - EARTH MOVING.pdf PDF
PG.dwg DWG drawing
EG.dwg DWG drawing
49-B861-26-01 BidTabulationReport.xlsx XLSX spreadsheet
24-2026-10-14 - CD Addendum 2.pdf PDF
25-061_Pitney Rd Warehouse_Arch-Structural-MEP Drawings_Addendum 3.pdf PDF
28-312000 - EARTH MOVING.pdf PDF
12-25061 - Addendum 1.pdf PDF
48-CD-18 UTILITY PLAN.pdf PDF
9-C06 - Pitney Rd Warehouse Arch-Structural-MEP Bid Set.pdf PDF
32-25-061 Pitney Rd Warehouse Arch-Structural-MEP Drawings Addendum 3.pdf PDF
37-133418-USER-Post Frame Building Systems-10-23-2026.pdf PDF
22-B861-26-01 ADDENDUM 2 - MULTIPRIME Operations Facility Expansion Project.docx DOCX document
25-2026-10-14 - ES Addendum 2.pdf PDF
18-329113 - SOIL PREPARATION.pdf PDF
41-2026-10-29 - ES Addendum 4.pdf PDF
ES.dwg DWG drawing
29-321723 - PAVEMENT MARKINGS.pdf PDF
25061 - Addendum 3_ Arch-struct-MEP summary.pdf PDF
44-B861-26-01 ADDENDUM 4 - MULTIPRIME Operations Facility Expansion Project.docx DOCX document
30-2026-10-23 - ES Addendum 3.pdf PDF
Easements.dwg DWG drawing
Landscape.dwg DWG drawing
16-25-061 Pitney Rd Warehouse Arch-Structural-MEP Addendum 1.pdf PDF
20-City of Lancaster 150 Pitney Road Phase 1 ESA Sept2026.pdf PDF
33-Addendum 03 Arch Front End Specs.pdf PDF
13-133419-RIB- Pre-Engineered Metal Building Systems-09-17-2026.pdf PDF
11-B861-26-01 FINAL - MULTIPRIME Operations Facility Expansion Project.docx DOCX document
26-Pre-Bid Attendees Ops Center Expansion 10072026.pdf PDF
40-2026-10-29 - CD Addendum 4.pdf PDF
38-25061 - Addendum 4 Arch-struct-MEP summary.pdf PDF
2026-10-23 - ES Addendum 3.pdf PDF
Addendum 03_Arch & Front End Specs.pdf PDF
39-25-061 Pitney Rd Warehouse Arch-Structural-MEP Drawings Addendum 4.pdf PDF
45-FINAL QA Report.pdf PDF
2026-10-23 - CD Addendum 3.pdf PDF
7-C09 - Fill Assessment Summary.pdf PDF
31-2026-10-23 - CD Addendum 3.pdf PDF
5-C03 - Operations Facilities Expansion - Bid Specs - Vol I.pdf PDF
312000 - EARTH MOVING.pdf PDF
46-CD-16 UTILITY PLAN.pdf PDF
Show 40 more

Latest 50 of 63 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EAST LAMPETER TOWNSHIP

CITY OF LANCASTER

SALT STORAGE

BUILDING

STORAGE BUILDING

STORAGE YARD

TRASH AREA

846 SF.

COVERED STORAGE

(2) LOADING

DOCKS

PROP. GENERATOR

LOCATION

PROP.

TRANSFORMER

LOCATION

12' GRAVEL PATH

FROST FREE HYDRANT (TYP.),

WOODWARD Y2 OR APPROVED

EQUAL

INSTALLED FORD METER BOX

COMPANY - BASIS OF DESIGN

PSBH-488-20-60-NL-FP:

CONTRACTOR TO CONFIRM

ACCEPTABILITY WITH CITY OF

LANCASTER WATER BUREAU

PRIOR TO ORDERING

"D O

N O

T

EX

PL

O

D E"

M A

TC

H

LI

N

E

LD

-1

LD

-1

"D O

N O

T

EX

PL

O

D E"

M A

TC

H

LI

N

E

LD

-1

LD

-1

LD-18

SHEET KEY MAP

LD-17

LD-16

8" DICL WATER MAIN PREVIOUSLY

INSTALLED BY CITY OF LANCASTER

"DO NOT EXPLODE"MATCHLINE

LD-17

LD-18

TERMINAL HYDRANT PREVIOUSLY

INSTALLED BY CITY OF LANCASTER

PROP. TAPPING

SLEEVE AND VALVE

MATERIAL STORAGE

PROP. GAS LINE, SEE MEP

DRAWINGS AND SPECIFICATION

PROPOSED TREE

PROTECTION FENCE (TYP.)

PROPOSED TREE

PROTECTION FENCE (TYP.)

EXTENTS OF EXISTING

VEGETATION TO REMAIN (TYP.)

EX. ELECTRIC / COMMUNICATIONS

UTILITY, IF ADJUSTMENT/REBURIAL

REQUIRED TO PROVIDE REQUIRED

COVER, UTILITY AND OWNER SHALL

RELOCATE AT OWNER'S EXPENSE.

GC IS REQUIRED TO COORDINATE

ACCESS AND INCORPORATE WORK

INTO SCHEDULE

EX. ELECTRIC TO BE REBURIED

PER UTILITY PROVIDER

SPECIFICATIONS, IF

INSUFFICIENT COVER WILL

RESULT FROM ROADWAY

GRADING, CONTRACTOR TO

TEST PIT AND CONFIRM

TD-A25 TO TIE

INTO PROPOSED

ROOF LEADER

PROP. FIRE

SUPPRESSION

6" LINE

PROP. DOMESTIC

6" WATER LINE

PROPOSED LIGHT

POST (TYP.)

PROPOSED

LIGHT POST

(TYP.)

6" ROOF LEADER

TIE-IN (TYP.)

6" ROOF LEADER

TIE-IN (TYP.)

8" ROOF LEADER

6" ROOF LEADER

TIE-IN (TYP.)

6" ROOF LEADER

TIE-IN (TYP.)

6" ROOF LEADER

TIE-IN (TYP.)

6" ROOF LEADER

TIE-IN (TYP.)

6" ROOF LEADER 6" ROOF LEADER

TIE-IN (TYP.)

INVERT OUT: 316.90

PROP. GAS

CONNECTION. REFER

TO MECHANICAL

DRAWINGS.

PROP. HYDRANT, SEE DETAIL

"D O

N O

T

EX

PL

O

D E"

M A

TC

H

LI

N

E C

D -1

C D

-1

"D O

N O

T

EX

PL

O

D E"

M A

TC

H

LI

N

E C

D -1

C D

-1

CD-18

SHEET KEY MAP

CD-17

CD-16

"DO NOT EXPLODE"MATCHLINE

CD-17

CD-18

I-A

I- A

I- A

I- A

M -A

M-A5

I-A7

I-A10

M-A16

M-A14

M-A12

M-A15

I-A20

I-A

I- A

M-A11

M -A22

I-A8

TD-A25

W W

W W

W W

W W

G

G G

G G

G G

G G

G G

G S

S S

S

S

S S

S S

S S

S S

S S

S S

S S

S S

W

CO-11

C O

-8

C O

-6

C O

-7

C O

-5

CO-9

CO-12 CO-14

CO-13

U E

U E

U E

U E

W W

W W

W W

W

WW

W

WWWWWW

W

W

(NOT IN SCOPE)

PROP. ELECTRICAL CONDUIT (SHOWN FOR

REFERENCE PURPOSES ONLY) PER PPL

SPECIFICATION, SEE ELECTRIC PLANS FOR

QUANTITY, SIZE AND DEMARCATION POINT.

ELECTRICAL CONTRACTOR IS RESPONSIBLE

FOR CONDUIT. CONDUIT TO RUN FROM CITY

INSTALLED QUAZITE BOX/ DEMARCATION

POINT

(NOT IN SCOPE)

PROP. COMMUNICATIONS

CONDUIT TO BE EXTENDED TO

PROPOSED TERMINATION POINTS

AS SHOWN ON THE ELECTRICAL

DRAWINGS, TO BE INSTALLED BY

CONTRACTOR

COMMUNICATIONS HANDHOLE

INSTALLED BY CITY OF

LANCASTER, TRAFFIC RATED

ELECTRIC HANDHOLE

INSTALLED BY CITY OF

LANCASTER, TRAFFIC RATED

GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL SUBGRADE

PREPARATION AND EARTHWORK. OTHER PRIME CONTRACTORS

TO COORDINATE WORK WITH GENERAL CONTRACTOR.

FROST FREE HYDRANT (TYP.),

WOODWARD Y2 OR APPROVED

EQUAL

INSTALLED FORD METER BOX

COMPANY - BASIS OF DESIGN

PSBH-488-20-60-NL-FP:

CONTRACTOR TO CONFIRM

ACCEPTABILITY WITH CITY OF

LANCASTER WATER BUREAU

PRIOR TO ORDERING

UTILITY NOTES:

1.GENERAL UTILITY NOTES:

a.WATER, SEWER, AND GAS UTILITY LINES ON THE PLANS REPRESENT THE CENTER OF THE UTILITY LINE OR TRENCH.

b.CONTRACTOR SHALL CONFIRM THAT MINIMUM VERTICAL CLEARANCES ARE PROVIDED AT ALL UTILITY CROSSINGS.

c. VERTICAL CLEARANCES SHALL BE PROVIDED AS FOLLOWS:

i. STORMWATER - MIN. 18" SEPARATION FROM SANITARY/STORM/WATER

ii. SANITARY - MIN. 18" FROM SANITARY/STORM/WATER

iii. WATER - MIN. 18" FROM SANITARY/STORM/WATER

iv. GAS - MIN. 12" FROM ALL OTHER UTILITIES v.AV/IT - MIN. 12" FROM ALL OTHER UTILITIES

vi. ELECTRIC - PER PPL REQUIREMENTS

2.ELECTRIC NOTES:

a.INSTALLATION OF PRIMARY AND SECONDARY DUCT BANKS SHALL BE PERFORMED BY THE ELECTRICAL CONTRACTOR. ALL TRENCHING TO BE PROVIDED BY THE GENERAL CONTRACTOR. SEE MEP PLANS FOR PRIMARY AND SECONDARY ELECTRICAL SERVICE DETAILS.

b.PPL SHALL PULL THE CABLES AND INSTALL THE XFMR AND METERING.

c.ELECTRICAL CONTRACTOR TO COORDINATE AND INSTALL ALL ONSITE ELECTRICAL CONDUIT FOR GENERATOR/BACK-UP POWER AND LIGHTING. SEE MEP

PLANS.

3.GAS NOTES:

a. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH UGI REGARDING GAS SERVICE INSTALLATION SCHEDULE.

b. THE GENERAL CONTRACTOR SHALL PROVIDE TRENCHING FROM THE EXISTING GAS LINE TO THE RISER/METER LOCATION(S).

c. THE GENERAL CONTRACTOR SHALL PROVIDE STONE DUST PER UGI SPECIFICATIONS AND HAVE THIS MATERIAL AVAILABLE FOR UGI'S USE AT THE TIME OF SERVICE LINE INSTALLATION. TRENCH SPOILS SHALL ALSO BE LOCATED ADJACENT TO THE TRENCH FOR UGI'S USE WHEN BACKFILLING.

d.THE SERVICE CONNECTION FROM THE GAS MAIN UP TO AND INCLUDING THE GAS METER SHALL BE INSTALLED BY UGI UTILITIES.

THE GENERAL CONTRACTOR SHALL INSTALL THE CONCRETE PAD FOR THE GAS METER PER UGI REQUIREMENTS, THIS SHALL BE INSTALLED PRIOR TO THE

INSTALLATION OF THE GAS METER.

SCRIPT:

SE

AL

SE

AL

MANAGER:

DATE:

PROJECT NO.:

OF

SHEET NO.:

C or po ra te O ffi ce

W es t J am es S tre et

Su ite

, L an ca st er , P

A

Ph on e:

(7

) 7

-1 w w w .rg sa ss oc ia te s.

co m

R eg io na l O ffi ce s:

Yo rk

, H ar ris bu rg , a nd P ao li

La nd

P la nn in g La nd sc ap e

Ar ch ite ct ur e

C iv il En gi ne er in g

XR

EF

S:

E xi st in g;

Ex is tin g-

G

IS

-S ur ve y;

La yo ut ;E as em en ts

;F lo od pl ai n;

Li gh tin g;

Z- U til ity

;P ro fil es

-U til iti es

PL

O

TT

ED

/2 /2

3:

P M

F

IL

EN

AM

E:

P

:\2

5\

2-

4\ C

AD

D

\C on st ru ct io n\ Pl ot \Z

-C D

-U til ity .d w g

N O

D

AT

E R

EV

IS

IO

N

O

PE

R

AT

IO

N

S

FA

C

IL

IT

Y

EX

PA

N

SI

O N

PI

TN

EY

R

O

AD

C O

N

ST

R U

C

TI

O N

P

LA

N

C

IT

Y O

F

LA

N C

AS

TE

R

LA

N C

AS

TE

R C

O U

N

TY

, P A

U

TI

LI

TY

P

LA

N

C

IT

Y O

F

LA

N C

AS

TE

R D

EP

AR

TM

EN

T O

F

PU

BL

IC

W O

R

KS

N O

R

TH

D U

KE

S

TR

EE

T P.

O . B

O X

LA

N

C

AS

TE

R

, P A

(7

) 2

-4

SC

AL

E:

0' 0'

SEPTEMBER 8, 2026

2025992-044

BENJAMIN MORTON, RLA

CD-17 54

/0 6/

AD

D

EN

D

U M

/1 4/

AD

D

EN

D

U M

/2 3/

AD

D

EN

D

U M

/2 9/

AA

D

EN

D

U M

Sheets and Views
CD-17 UTILITY PLAN