4-MCCC Master Signage Plan - Construction Documents.pdf
PDF 11 MB Posted
- Solicitation number
- Not on record
- Issued by
- Montgomery County, Pennsylvania
About this file
This document is a comprehensive Signage Master Plan Construction Document for Montgomery County Community College, prepared by KMA Design. The plan details an extensive signage system for the college's Blue Bell and Pottstown campuses, covering exterior and interior signage types including monument signs, gateway signs, directional signs, building identification signs, room identification signs, and parking signage. The documents are dated October 1, 2023, with construction documents finalized on December 2, 2024, and the project managed by Marianna Mohney.
The signage system is meticulously designed with a consistent visual language, utilizing a color palette featuring PMS 186 (red), PMS 447 (dark gray), and Matthews Brushed Aluminum, with the Montgomery County Community College logo prominently featured. The design includes various sign types such as ST01 Monument Signs, ST03 Vehicular Wayfinding Signs, ST10 Room Identification Signs, ST25 Department Identification Signs, and ST31 Parking Garage Graphics. Materials specified include 1/8" and 3/8" acrylic panels, aluminum cabinets, perforated aluminum, and vinyl graphics, with careful attention to ADA compliance, including Braille and raised lettering. The comprehensive plan covers both campuses and encompasses exterior building signs, interior directional signage, room markers, and specialized graphics for parking areas and informational displays.
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2023-10-01 /// Signage Master Plan
C O N S T R U C T I O N D O C U M E N T S 12-02-2024
S P E C I F I C A T I O N S
E X T E R I O R S I G N A G E
No part of this document may be reproduced or utilized in any form, without prior written authorization by Kerestes-Martin Associates, Inc. (DBA, KMA Design)
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Typography Colors
General Notes
Perforated Aluminum
01. Written dimensions on drawings take precedence over scaled dimensions. Sign contractor shall verify and be responsible for all dimensions and conditions shown on drawings.
02. Sign contractor shall verify all existing conditions prior to shop drawings and bring any discrepancy between the drawing and the actual condition to the owner’s attention prior to fabrication.
03. The sign contractor shall provide signed and sealed engineered drawings for all signs including structural and wind load requirements. All Electrical Components to be UL compliant and all wiring connections shall be included in the drawing package, signed, and sealed by a licensed PE registered in the state of Pennsylvania. Electrical engineered connections shall be submitted with the shop drawings and stamped by an engineer registered locally. Montgomery County Community College to provide power, fabricator responsible for final hook-up.
04. All colors and finishes shall be approved by the owner prior to the production of sign units.
05. Sign contractor shall provide full size mock-ups of designated prototypes for owner approval before proceeding with sign fabrication and installation.
06. Paint / Color / Materials shown in drawings shall be continuous around edges and continuous faces. Utilize AkzoNobel® GripGard® Signage Paints.
AkzoNobel 1845 Maxwell Drive, Troy, MI 48084AKZ-9000-8041. - grip-gard.com
07. Typefaces shall not be supplied to contractor. Contractor shall obtain the licensed edition for their own use.
08. Ensure Perpendicular signs are installed with with a maximum tolerance of 3 degrees angled toward the road.
Arrows
Logo
Paint Description Vinyl Description
PMS 186 - w/ Satin Clear Oracal® - 951 - 348 Scarlet Red
Hind - Semi Bold
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z 1 2 3 4 5 6 7 8 9 0
Highway Gothic - Condensed
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z a b c d e f g h i j k l m n o p q r s t u v w x y z 1 2 3 4 5 6 7 8 9 0
MPS Brushed Aluminum - w/ Satin Clear Oracal® - 951 - 711 - Stone Grey
PMS Black - w/ Satin Clear Oracal® - 951 - 070 - Black
PMS 447 - w/ Satin Clear Oracal® - 951 - 073 - Dark Grey
PMS White - w/ Satin Clear Oracal® - 951 - 010 - White
PMS - Black MPS - Brushed Aluminum
PMS - WhitePMS - 447PMS - 186
1 3/8"
1/
8" Ø 3/4"
5/8" 5/8"
1 3/4"
5/
8"
7/8" 7/8"
Ø 1"
1/2"
1/ 2"
Ø 1/2"
7/8"
3/ 4"
1/2"1/2"
1/2” min. along outside edges
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Montgomery County Community College Signage Master Plan
2023-10-01
12-05-2024
Marianna Mohney
Construction Documents
No part of this document may be reproduced or utilized in any form, without prior written authorization by Kerestes-Martin Associates, Inc. (DBA, KMA Design)
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Sheet:© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350 13
Scale - NTS Gateway Signage Elevation 02
Scale - NTS Monument Signage Elevation 01
Sign Type 01.3 - Tertiary Gateway Blue Bell Campus
Sign Type 01.2 - Secondary Gateway Pottstown Campus
Sign Type 01 - Monument Blue Bell Campus
Sign Type 01.1 - Primary Gateway Blue Bell Campus
340 DeKalb Pike Blue Bell, PA 19422
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Scale - NTS Directional Signage Elevation 01
Scale - NTS Parking Signage Elevation 02
Sign Type 03 - Primary Vehicular Wayfinding Blue Bell Campus
Health Sciences Center
Advanced Technology Ctr.
College Hall
Hospitality Institute
Fine Arts Center
Parkhouse Hall
Academic Affairs & Provost
Veterans Center
Science Center
Auditorium
Sign Type 03.1 - Secondary Vehicular Wayfinding Blue Bell Campus
Health Sciences Center
Advanced Technology Ctr.
College Hall
Hospitality Institute
Fine Arts Center
Parkhouse Hall
Academic Affairs & Provost
Veterans Center
Science Center
Auditorium
Sign Type 03.2 - Tertiary Vehicular Wayfinding Blue Bell Campus
Route 202 Parking
Advanced Technology Ctr.
College Hall
Fine Arts Center
Hospitality Institute
Parkhouse Hall
Sign Type 04 - Pedestrian Directional Blue Bell Campus Pottstown Campus
Health Sciences Center
Advanced Technology Ctr.
Fine Arts Center
Hospitality Institute
Parkhouse Hall
Veterans Center
Sign Type 06 - Parking Identification Blue Bell Campus Pottstown Campus
Cathcart Parking Lot
Sign Type 06.1 - Parking Identification - Flag Blue Bell Campus Pottstown Campus
Cathcart Parking
A
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Scale - NTS Building Identification / Kiosk Signage Elevation 01
Sign Type 02 - Pedestrian Informational Kiosk - Large Not-In-Scope
Sign Type 02.1 - Pedestrian Informational Kiosk - Small Blue Bell Campus Pottstown Campus
Sign Type 05 - Primary Building Identification Blue Bell Campus Pottstown Campus
Sign Type 05.1 - Secondary Building Identificati Blue Bell Campus Pottstown Campuson
Veterans Resource Center
College Hall Admissions • Career Services
Enrollment Services • Financial Aid Human Resources • Library
President's Office • Public Safety
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Sign Type 01 - Monument - Blue Bell Campus (Single Sided) Elevation Scale - 3/8” = 1’ 0”02
Sign Type 01 - Monument - Blue Bell Campus (Single Sided) Plan View Scale - 3/8” = 1’ 0”01
Sign Type 01 - Monument - Blue Bell Campus (Single Sided) End View Scale - 3/8” = 1’ 0”03
8' -0
3"
24'-6"
8" 7'
-4
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
8' -0
3"
1'-0"23'-0"6"
3' -5
1"
4' -6
3' -5
1"
4' -6
EQ
1'
-5 1 /
8" 7"
1 /
4"
EQ
EQ
1'
-5 1 /
8" 7"
1 /
4"
EQ
3' -0
1 / 2"
1 /
2"
1"
EQ 2'-10 3/4" 7"
1 1/2"
24'-6"
1'-0"23'-0"6"
8" 16'-4" EQ
2'-5"
2'-5"
6 1/2" 6 1/2"1'-4"
2' -5
1 /
2"
1 / 2"
1' -4
1 /
2"
1 / 2"
1' -4
3" 24'-6" 3"
3" 24'-6" 3"
3" 3"
3" 3"
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Sign Type 01 - Monument - Blue Bell Campus (Single Sided) Elevation Scale - 3/8” = 1’ 0”01 Sign Type 01 - Monument - Blue Bell Campus (Single Sided)
End View Scale - 3/8” = 1’ 0”02
PMS - Black MPS - Brushed Aluminum
PMS - WhitePMS - 447PMS - 186
1 3/4"
5/
8"
7/8" 7/8"
Ø 1"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1” Conduit For Power Supply
- 120V 20 AMP Circuit
- Coordinate Power With Owner
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 1“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel With First Surface Translucent Silver
1” Push Through Acrylic
- Face Translucent White Vinyl
- Edges Clear For Wash Illumination
1” Push Through Acrylic
- Face Translucent White Vinyl
- Edges Clear For Wash Illumination
1/2” Push Through Acrylic
- Face Translucent White Vinyl
- Edges Clear For Wash Illumination
1” Reveal
- Painted PMS Black
1/8” Aluminum Sign Cabinet
- Painted PMS 447
- Internal Illumination White LED’s
1/8” Aluminum Sign Cabinet
- Painted MPS Brushed Aluminum
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Sign Type 01.1 - Primary Gateway - Blue Bell Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 01.1 - Primary Gateway - Blue Bell Campus (Double Sided)
End View Scale - 1/2” = 1’ 0”02
'-9
3"
'-0
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-9
3"
'-0
1" 2'
-2
8' -6
1" 2'
-2
8' -6
EQ
3 / 4"
1 /
4"
5 / 8"
EQ
7'
-0
1 /
2"
1 / 2"
1' -1
1"
1 / 2"
8'-2"
3"EQ 6'-8" EQ 8"
7'-0"1 1/2" 1 1/2" 5"
'-1
8'-2" 1 1/2"1 1/2" 1 1/2" 1 1/2"
1'-6"
1'-6"
4 1/2" 9" 4 1/2"
1"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1” Conduit For Power Supply
- 120V 20 AMP Circuit
- Coordinate Power With Owner
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 1“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel With First Surface Translucent Silver
Routed Aluminum
- Backed With White Acrylic
- Flush Mounted Acrylic Letters/Logo
1” Reveal
- Painted PMS Black
1/8” Aluminum Sign Cabinet
- Painted PMS 447
- Internal Illumination White LED’s
1/8” Aluminum Sign Cabinet
- Painted MPS Brushed Aluminum
LED Message Center
- CIRRUS Systems Inc
- 7’ 0” X 7’ 0” BLADE EM
- 8mm
- Or equal
SIMILAR
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Sign Type 01.2 - Secondary Gateway - Pottstown Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 01.2 - Secondary Gateway - Pottstown Campus (Double Sided)
End View Scale - 1/2” = 1’ 0”02 Sign Type 01.2 - Secondary Gateway - Pottstown Campus (Double Sided) End View Scale - 1/2” = 1’ 0”03
5'-0"
5'-0"
'-0
3"
'-3
3" 4'-2" 7"
4'-0"1" 1"
4' -0
5 / 8"
2" 4"
1 /
2" 3"
1 /
2"
1 / 2"
1 /
2"
1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2"
1' -1
0"
5"
'-7
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-0
'-3
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-0
3"
'-3
5"
'-7
2' -1
1"
9' -1
1"
2' -1
1"
9' -1
1"
2' -1
1"
9' -1
1"
3"
1'-2"
1'-2"1'-2"
6" 4"4"
1'-2"
6" 4"4"
1"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1” Conduit For Power Supply
- 120V 20 AMP Circuit
- Coordinate Power With Owner
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 1“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel With First Surface Translucent Silver
Routed Aluminum
- Backed With White Acrylic
- Flush Mounted Acrylic Letters/Logo
1” Reveal
- Painted PMS Black
1/8” Aluminum Sign Cabinet
- Painted PMS 447
- Internal Illumination White LED’s
1/8” Aluminum Sign Cabinet
- Painted MPS Brushed Aluminum
LED Message Center
- CIRRUS Systems Inc
- 4’ 0” X 4’ 0” BLADE EM
- 8mm
- Or equal
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Sign Type 01.3 - Tertiary Gateway - Blue Bell Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 01.3 - Tertiary Gateway - Blue Bell Campus (Double Sided)
End View Scale - 1/2” = 1’ 0”02 Sign Type 01.3 - Tertiary Gateway - Blue Bell Campus (Double Sided) End View Scale - 1/2” = 1’ 0”03
'-9
1' -1
6'
-8
'-0
6" 2"
2" 3"
6' -8
1'
-6
6' -5
1'
-9
3"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-9
1' -1
6'
-8
'-0
6" 2"
2" 3"
6' -8
1'
-6
6' -5
1'
-9
3"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-9
1' -1
6'
-8
'-0
6" 2"
2" 3"
6' -8
1'
-6
6' -5
1'
-9
3"
6'-6"
5'-9" 9"
8" 6" 1"1"
2' -1
2'
-6
2' -1
1'-0"
1" 6" 1"
1'-0"
3 5/8" 4 3/4"
3 5/8"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
Applied Reflective White Vinyl
1/8” Aluminum Sign Cabinet
- Painted PMS 447
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Pole Mounting Methods
Breakaway Base Concrete Mount Direct Burial
Mounting Options Elevation Scale - NTS01 Mounting Options
Elevation Scale - NTS02 Mounting Options Elevation Scale - NTS03
Pole-Safe ® Breakaway Support System Concrete Footer And Attachment Method TBD By Structural Engineer Based On Soil Conditions
Concrete Footer And Attachment Method TBD By Structural Engineer Based On Soil Conditions
Concrete Footer TBD By Structural Engineer Based On Soil Conditions
Red Head® Wedge Anchors Or Similar
- Diameter And Lenghth TBD By Structural Engineer
Weld 1/2” Aluminum Plate To Pole Secure To Concrete Footer Or Existing Concrete Pad With Red Head® Wedge Anchors Or Similar
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Sign Type 02 - Pedestrian Informational Kiosk - Large - (Single Sided) Not-In-Scope Elevation Scale - 1/2” = 1’ 0”01 Sign Type 02.1 - Pedestrian Informational Kiosk - Small - Blue Bell Campus & Pottstown Campus (Double Sided)
End View Scale - 1/2” = 1’ 0”02
3" 6'
-0
SIMILAR
SIMILAR
SIMILAR
SIMILAR
1" 6"1" 1 /
2"
1"6' -3
5' -6
6"
1'-0 3/4" 1'-2" 1'-0 3/4"
4'-3"
3 1/2" 3'-3 1/2" 8"
7" 3'
-2 1 /
2" 2'
-8 1 /
2"
3 /
4" 2'
-5
3 /
4"
3 / 4"
2' -3
2' -3
3 /
4"
1 /
2" 9"
1 /
2"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
2' -9
5"
3'-4"
2'-11" 5"
5' -8
3"
1 / 2"
1 /
2" 2"
2' -3
6"
1' -4
9"
2"
1" 2'
-1
1"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 186
2” Concrete Base Exposure
- 1 1/4” Chamfer Edge
Applied Vinyl Full Color Map Digital Print
- Map By OthersApplied Vinyl
Full Color Map Digital Print
- Map By Others
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 447
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 1/2“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel With First Surface Translucent Silver
1” Reveal
- Painted PMS Black
1” Aluminum Disc Painted PMS 186 With Applied Translucent Red Vinyl
- PMS 186
On Reflective White Vinyl
1/8” Aluminum Sign Cabinet
- Painted PMS 447
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Health Sciences Center
Advanced Technology Ctr.
College Hall
Hospitality Institute
Fine Arts Center
Parkhouse Hall
Academic Affairs & Provost
Veterans Center
Science Center
Auditorium
Sign Type 03 - Primary Vehicular Wayfinding - Blue Bell Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 03 - Primary Vehicular Wayfinding - Blue Bell Campus
End View Scale - 1/2” = 1’ 0”02 Sign Type 03 - Primary Vehicular Wayfinding - Blue Bell Campus End View Scale - 1/2” = 1’ 0”03
'-0
3"
'-3
8"
'-4
5" 1'-0 1/2" 5" Varies Per Message
5" 8'-2" 1'-1"
9'-8"
3' -6
'-4
2"
3' -6
'-4
2"
3' -6
'-4
2"
3' -2
1" 2 1 /
2"
1 / 2"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-0
3"
'-3
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-0
3"
'-3
8"
'-4
2" 2" 2" 2" 2"2" 9'-8"
5"
3 / 8"
9"
1 / 2"
1' -4
1 / 2"
1'-4"
7"4 1/2" 4 1/2"
1'-4"
7"4 1/2" 4 1/2"
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
Health Sciences Center
Advanced Technology Ctr.
College Hall
Hospitality Institute
Fine Arts Center
Parkhouse Hall
Academic Affairs & Provost
Veterans Center
Science Center
Auditorium
Health Sciences Center
Advanced Technology Ctr.
College Hall
Hospitality Institute
Fine Arts Center
Parkhouse Hall
Academic Affairs & Provost
Veterans Center
Science Center
Auditorium
Sign Type 03.1 - Secondary Vehicular Wayfinding - Blue Bell Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 03.1 - Secondary Vehicular Wayfinding - Blue Bell Campus (Double Sided)
Materials Scale - 1/2” = 1’ 0”02
SIMILAR
SIMILAR
'-0
3 5/8" 9 3/8"
3 5/8" Varies Per Message
7'-3"
3" 6'-2" 10"
'-2
3"
6"
'-5
9' -2
1 / 2"
2' -8
1 / 2"
3 /
4"3 5 /
8"
3 / 4"
1 /
4" 1'
-0
1 /
4"
2"2"
2" 2'
-4
2"
1"
7'-3"
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 1“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel
Applied Reflective White Vinyl
1” Reveal
- Painted PMS Black
Applied Translucent Red Vinyl
- PMS 186
On Reflective White Vinyl
Applied Reflective White Vinyl
Applied Vinyl Rule Lines
- PMS Cool Grey 4
1/8” Aluminum Sign Cabinet
- Painted PMS 447
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Health Sciences Center
Advanced Technology Ctr.
Fine Arts Center
Hospitality Institute
Parkhouse Hall
Veterans Center
Sign Type 03.2 - Tertiary Vehicular Wayfinding - Blue Bell Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-9
1' -1
6'
-8
'-0
6" 2"
2" 3"
6' -8
1'
-6
6' -5
1'
-9
3"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
6'-6"
5'-9" 9"
8" 6" 1"1"
01 Sign Type 03.2 - Tertiary Vehicular Wayfinding - Blue Bell Campus End View Scale - 1/2” = 1’ 0”02 Sign Type 04 - Pedestrian Directional - Blue Bell Campus & Pottstown Campus (Double Sided)
Elevation Scale - 1/2” = 1’ 0”03
Route 202 Parking
Advanced Technology Ctr.
College Hall
Fine Arts Center
Hospitality Institute
Parkhouse Hall
5 /
8"
1 / 4"
3 /
8" 3"
3 /
4" 3"
9"3" 3" Varies Per Message
1 3/4" 4" 2 5/8" 1 1/2" 2 3/8" 1 1/2"
'-1
7" 3'
-4
9' -2
3" 1"1"
2"
3' -4
9"
7' -5
2"
4" 1/2"1/2"
4"
3'-4"
2'-11" 5"
SIMILAR
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
Applied Reflective White Vinyl
Applied Translucent Red Vinyl
- PMS 186
On Reflective White Vinyl
1/8” Aluminum Mounted To A 1” Aluminum Tube Frame
- Painted PMS 447
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
'-9
1' -1
6'
-8
'-0
6" 2"
2" 3"
6' -8
1'
-6
6' -5
1'
-9
3"
1'-0"
3 5/8" 4 3/4"
3 5/8"
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
SIMILAR
SIMILAR
Sign Type 05 - Primary Building Identification - Blue Bell Campus & Pottstown Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 05.1 - Secondary Building Identification - Blue Bell Campus & Pottstown Campuson (Double Sided)
Elevation Scale - 1/2” = 1’ 0”02
College Hall Admissions • Career Services
Enrollment Services • Financial Aid Human Resources • Library
President's Office • Public Safety
SIMILAR
SIMILAR
1" 6"1"
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
5"
3"
1 / 2"
1 /
2" 2"
6" 9"
2" 2'
-0
340 DeKalb Pike
Veterans Resource Center
6' -1
0"
3' -0
4'-1"
3'-8 1/2" 4 1/2"
2"
3 / 8"
EQ
3"
3"1 1 /
2" 3"
1 /
2"
EQ
4' -5
1 / 4"
2' -7
3 / 4"
3 / 4"
7' -3
6" 6'
-7
3"
3 1/2" 5'-10" 7 1/2"
6'-9"
2" 2'
-3
2" 4"
7"
EQ
7"
1 / 4"
5 /
8"
1 / 8"
1 /
8"
5 / 8"
1 /
8"
5 / 8"
EQ
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Sign Cabinet
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
1/8” Aluminum With 3/4“ Perforation
- Painted PMS 447
- Backed With Diffuser Panel With First Surface Translucent Silver
Applied Reflective White Vinyl
3/4” Reveal
- Painted PMS Black
Applied Reflective White Vinyl
1/8” Aluminum Sign Cabinet
- Painted PMS 447
1/8” Aluminum Sign Cabinet
- Painted MPS Brushed Aluminum
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
2” Concrete Base Exposure
- 1 1/4” Chamfer Edge
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Cathcart Parking
A
Sign Type 06 - Parking Identification - Blue Bell Campus & Pottstown Campus (Double Sided) Elevation Scale - 1/2” = 1’ 0”01 Sign Type 06.1 - Parking Identification - Triangular - Blue Bell Campus & Pottstown Campus
Elevation Scale - 1/2” = 1’ 0”02
SIMILAR
SIMILAR
1" 6"1" 2'
-3
C on cr et e Fo ot er
T
BD
By S tru ct ur al
E ng in ee r To
C om pl y
W ith
A ll
Lo ca l C od es
A nd
W in d-lo ad s
5"
3'-4"
2'-11" 5"
3"
1 / 2"
1 /
2" 2"
2' -3
6"
9" 2"
Cathcart Parking Lot
2' -0
6' -4
EQ
4"
2"
1 / 2"
1 /
2" 3"
1 /
2"3"
EQ
3' -2
2'-8" 4"
3'-0"
Fi el d Ve rif y
H ei gh t V ar ie s Pe r L oc at io n
EQ
3 / 8"
4"
5 / 8"
1 /
8"
5 / 8"
3 /
8" 1'
-1 1 /
2"
EQ
Concrete Footer
- Engineer to Verify Diameter and Depth of Footer
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 186
3” Concrete Base Exposure
- 1 1/2” Chamfer Edge
Applied Reflective White Vinyl
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 447
1/8” Aluminum Mounted To 1” Aluminum Tube Frame
- Painted PMS 186
- Mounting Hardware TBD By Fabricator
- Fabricator to Verify Existing Pole Prior to Fabrication
Applied Reflective White Vinyl
1/8” Aluminum Mounted To A 1” Aluminum Tube Frame
- Painted PMS 447
- Mounting Hardware TBD By Fabricator
- Fabricator to Verify Existing Pole Prior to Fabrication
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Decorative Aluminum Sleeve
- Painted MPS Brushed Aluminum
Aluminum Pole
- Painted MPS Brushed Aluminum
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
The two aluminum sign frames (top and bottom) are attached to the light poles with two 8”stainless steel U-Bolts
Each light pole sign consists of 3 - 36”x 38” x .080 aluminum panels, attached to two, 3 sided 2” aluminum sign frame as shown below.
Existing Light Pole
Existing Pole Mounting
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Sign Type 08 - Accessible Parking Elevation Scale - 2” = 1’ 0”01 Sign Type 08.1 - Reserved Parking
Elevation Scale - 2” = 1’ 0”02
VIOLATORS ARE SUBJECT
TO A FINE UP TO
$500.00
6"
Visitor Parking
Only 1/8” Aluminum Panel
- Painted PMS 186 /PMS 477
- Mounting Hardware TBD By Fabricator
Aluminum Pole
- Painted PMS 477
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
1/8” Aluminum
- Standard Reflective DOT Panel
- Mounting Hardware TBD By Fabricator
1/8” Aluminum
- Standard Reflective DOT Panel
- Mounting Hardware TBD By Fabricator
Aluminum Pole
- Painted PMS 477
- Fabricator To Determine Diameter And Wall Thickness Based Upon Engineered Drawings
Applied Reflective White Vinyl
Applied Reflective White Vinyl
1'-0"
1' -6
5'
-0
1'-0"
1' -6
5'
-0
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Sign Type 09.1 Parking Garage Cut Out Letters (Small) Elevation Scale - 3/4” = 1’ 0”02
Sign Type 09 Parking Garage Cut Out Letters (Large) Elevation Scale - 3/4” = 1’ 0”01
Sign Type 09 Parking Garage Cut Out Letters End View / Section Scale - Full03
1” Aluminum Cast Letter Painted PMS 447 Returns To Match Mechanically Fasten
1"
1' -0
1"
1' -0
1' -0
11'-11"
5'-10 1/2" 6" 5'-6 1/2"
8'-11"
4'-4 1/2" 5" 4'-1 1/2"
9"
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
Sign Type 09.2 - Parking Garage Clearance Bar Elevation Scale - 1/2” = 1’ 0”01
Clearance X’- X”6"
PVC Pipe
- Painted Safety Yellow
Aircraft Cable / Eyelet Screw
- Height Field Verified
Black Vinyl
PVC Pipe Cap
- Painted Safety Yellow
3" 7'-8" 3"
EQ 2'-6" EQ
1 /
2"
I N T E R I O R S I G N A G E
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
72”
96”
60”
36”
ADMISSIONS
ADMISSIONS
CLASSROOM
Professor Michael P. Longname
Biology
ADMISSIONS
LECTURE
HALL
LECTURE HALL
IN USE
X-RAY #2
RADIATION
RESTROOM
RESTROOM
EXIT
EXIRT
EXIT
EXIRT
A-1
ST10
Room Identification
ELECTRIC KILN
ROOM
ELECTRIC KILN ROOM
ST10.5
Room Identification - Exterior Grade
DARK ROOM
First Penn Charitable
Foundation
DARK ROOM
ST10.4
Room Identification DonorST10.1
Room Identification w/ Insert
OFFICE
Michael P. Longname
ADMISSIONS
ST10.6
Office Identification w/ 2 Inserts
ST11
Door Numbering - Exterior
ST10.2
Room Identification w/ Symbol
ST10.3
Room Identification w/ In-Use Slider
ST12
Restroom Identification
ST13
Exit Plaque
ST13.2
Exit Plaque - Exterior Grade
ST14
Evacuation Map
ST12.1
Restroom Identification - Flag Mount
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
72”
96”
60”
36”
Computer Lab 127 Mulitmedia 128 2D Sign 133 Print Making 134 Photography 135 Drawing A 136 Drawing B 141 Faculty Oces
NORTH WING
Computer Networking and Cyber Security
Admissions Restrooms Rooms 1001 - 1025
Computer Lab Learning Studio Library Rooms 1026 - 1050 Blank Message Line Blank Message Line Blank Message Line Blank Message Line Blank Message Line Blank Message Line Blank Message Line
Computer Networking and Cyber Security
Admissions Restrooms Rooms 1001 - 1025
Computer Lab Learning Studio Library Rooms 1026 - 1050 Blank Message Line Blank Message Line
Computer Networking and Cyber Security
Admissions Restrooms Rooms 1001 - 1025
Computer Lab Learning Studio Library Rooms 1026 - 1050 Blank Message Line Blank Message Line
Computer Networking and Cyber Security
Admissions Restrooms Rooms 1001 - 1025
Computer Lab Learning Studio Library Rooms 1026 - 1050 Blank Message Line Blank Message Line
Computer Networking and Cyber Security
Admissions Restrooms Rooms 1001 - 1025
ST19
Directory
ST20
Wall Mounted Directional - Large
ST20.1
Wall Mounted Directional - Medium
ST20.2
Wall Mounted Directional - Small
ST20.3
Wall Mounted Directional -
XL
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
72”
96”
60”
36”
IN CASE OF FIRE
DO NOT USE
ELEVATOR USE
EXIT STAIRS
IN CASE OF FIRE DO NOT SUE
ELEVATOR USE EXIT STAIRS
STAIR 01
FIRE DOOR
KEEP CLOSED
STAIR 01 FIRE DOOR KEE
KEEP CLOSED
STAIR B
LEVEL
LEVEL 1 TO LEVEL 8
NO ROOF ACCESS
EXIT DISCHARGE
1 LEVEL DOWN
COMPUTER
NETWORKING
AND
CYBER
SECURITY
COMPUTER NETWORKING
AND CYBER SECURITY
MAXIMUM
OCCUPANCY
PERSONS
MAXIMUM OCCUPANCY
100 PERSONS NO SMOKING
OR VAPING
NO SMOKING OR VAPING
N5 C201
Computer Networking and Cyber Security
Restrooms Rooms 1001-1025
Admissions Computer Networking and Cyber Security
Restrooms Computer Networking and Cyber Security
ST23
In Case of Fire
ST24
Stair Plaque
STAIR 01
FIRE DOOR
KEEP CLOSED
STAIR 01 FIRE DOOR KEE
KEEP CLOSED
ST24.2
Stair Plaque - Exterior Grade
ST24.1
Photolumines-cent Level ID with Egress
ST25
Department Identification
ADVANCED
TECHNOLOGY
CENTER
COMPUTER NETWORKING
AND CYBER SECURITY
ST25.2
Department Identification - Exterior Grade
ST26
Maximum Occupancy
ST27
No Smoking or Vaping - Wall Mounted
ST28
Informational Insert - Large
ST28.1
Informational Insert - Small Vertical
ST28.2
Informational Insert - Small Horizontal
ST28.1
Informational Insert - Table Top Vertical
ST29
Cubicle Identification
ST21
Overhead Directional - Large
ST21.1
Overhead Directional - Medium
ST21.2
Overhead Directional - Small
Computer Networking and Cyber Security
ST22
Flag Directional
ST25.1
Department Identification - Overhead
Dental Hygiene & Massage Therapy
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
72”
96”
60”
36”
Educational Gymnasium Elevator Police Academy Restrooms Rooms 1370-1921
Dental Hygiene Massage Therapy
Athletic Department Locker Rooms Main Gymnasium Rooms 1110-1365
ST21.3
Overhead Directional - Extended
ST30
Cut Out Letters - Large
BLK
ST30.1
Cut Out Letters - Medium BLK
ST30.1
Cut Out Letters - Small
BLK
ST30.3
Cut Out Letters - Large Alum.
ST30.4
Cut Out Letters - Medium Alum.
ST31
Parking Garage Graphics
ST31.1
Parking Garage Graphics
ST30.5
Cut Out Letters - Small Alum.
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
ST10 Room Identification Elevation Scale - 1/2” = 1”01 ST10 Room Identification
End View / Details Scale - 1/2” = 1”02
1/8“ (P95) Acrylic Panel
1/32” THK. Rowmark Grade II Braille
3/8” (P95) Acrylic Panel
VHB And Silicone
Existing Wall
ADMISSIONS
ADMISSIONS
8"
Material: 3/8” (P95) Acrylic Panel Painted PMS 447 On First Surface Color Accent Stripe: First Surface Painted PMS 186 Room Number Panel: 1/8“ (P95) Acrylic Panel First Surface Painted PMS 186 Copy: 1/32” THK. Rowmark Raised ADA Letters (T1) PMS White Font: Hind Bold +10 Braille: Clear Rasterized Beads Grade II Braille Mounting: VHB And Silicone
1 3/8" 5 1/4" 1 3/8"
2" 5 /
8" 3 /
8" 1 /
4" 1"
1" 3 /
8" 1 /
4"
2" 5 /
8" 3 /
8" 1 /
4" 1"
1" 3 /
8" 1 /
4"
3 /
4"
4 1/8"
3" 8"
3" 8"
1/8" 3/8"
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College Signage Master Plan
340 DeKalb Pike Blue Bell, PA 19422
2023-10-01
12-05-2024
Marianna Mohney
© KMA Design, All Rights Reserved. | www.thekmagroup.com | 104 Broadway Street, Carnegie, PA 15106 | 855.878.2350
Construction Documents
ST10.1 Room Identification w/ Insert Elevation Scale - 1/2” = 1”01 ST10.1 Room Identification w/ Insert
End View Scale - 1/2” = 1”02
CLASSROOM
Professor Michael P. Longname
Biology
ADMISSIONS
1/8“ (P95) Acrylic Panel
1/32” THK. Rowmark Grade II Braille
3/8” (P95) Acrylic Panel
VHB And Silicone
Window Insert/VHB
Existing Wall
8"
Material: 3/8” (P95) Acrylic Panel Painted PMS 447 On First Surface Color Accent Stripe: First Surface Painted PMS 186 Room Number Panel: 1/8“ (P95) Acrylic Panel First Surface Painted PMS 186 1/16” Clear Non Glare Window Insert Adhere To Face With VHB Tape (Insert By Others) Insert: 1/32” Polycarbonate Insert With Direct Digital Print Copy: 1/32” THK. Rowmark Raised ADA Letters (T1) PMS White Font: Hind Bold +10 Braille: Clear Rasterized Beads Grade II Braille Mounting: VHB And Silicone
1 3/8" 5 1/4" 1 3/8"
5 / 8"
3 / 8"
1 / 4"
1" 1"
3 / 8"
1 / 4"
1" 1"
3 / 8"
1 / 4"
3 /
4"
4 1/8"
3"
1/8" 3/8"
1' -0
3 / 4"
1' -3
3" 1'
-0
1' -3
9"
5 / 8"
3 / 8"
1 / 4"
3 / 4"
9"
First Surface Painted On Non Glare Window
PMS 186
These drawings are meant for DESIGN INTENT ONLY and are not for construction.
Contractor shall verify and be responsible for all dimensions and conditions of the job. Contractor shall be familiar with the site and conditions it presents. KMA must be notified of any variations from the dimensions and conditions shown on this drawing. Shop drawings and details must be submitted for approval prior to proceeding with fabrication. All copy shall be proofread by client and legal requirements checked by legal department.
Project:
Address:
Project Number:
Date:
Project Manager:
Issued for:
Sheet:
Montgomery County Community College…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .