About this file

This set of architectural drawings and specifications outlines renovations and infrastructure upgrades to telecommunications rooms in Building 1 at the Chalmers P. Wylie VA Medical Center in Columbus, Ohio. The project involves demolishing and upgrading electrical, mechanical, and network equipment in 14 telecom rooms across four levels of the building. Renovations will include installing new flooring, walls, doors, and ceiling finishes. Mechanical upgrades include adding ductless split units and relocating air diffusers. Electrical work consists of moving panels and equipment. The server room will be reconfigured and temporarily relocated in phases to minimize network downtime. The contract also involves roof repairs and replacing rooftop HVAC units. Specifications cover door schedules, finishes, and general construction notes.

View the file

Other files

File Type Posted
Amd 11 Att - RFI Responses_3.12.24.pdf PDF
36C77623R0150 0011.docx DOCX document
36C77623R0150 0010.docx DOCX document
Amd 10_1791.19 - RFI Responses_3.11.24.pdf PDF
Amd 10 23 07 11 HVAC and Boiler Plant Insulation2.pdf PDF
36C77623R0150 0009.docx DOCX document
36C77623R0150 0008.docx DOCX document
OIT Infrastructure Standard for Telecommunications Spaces - Version 3.1.pdf PDF
36C77623R0150 0007.docx DOCX document
Amendment 6 All Files.zip ZIP file
36C77623R0150 0006.docx DOCX document
36C77623R0150 0005.docx DOCX document
36C77623R0150 0004.docx DOCX document
757-22-705 Pre-Bid Site Visit Sign In.pdf PDF
36C77623R0150 0003.docx DOCX document
02_Hazardous Materials.pdf PDF
01_General.pdf PDF
06_Mechanical_Drawings.pdf PDF
07_Electrical.pdf PDF
03_Structural.pdf PDF
08_Telecom.pdf PDF
05_Fire Protection.pdf PDF
Columbus EHRM FINAL SPECS VOL 1.pdf PDF
Columbus EHRM FINAL SPECS VOL 2.pdf PDF
36C77623R0150 0002.docx DOCX document
36C77623R0150 0001.docx DOCX document
Attachment 15 -Site Visit Instructions Revised.docx DOCX document
Attachment 11 - 07_Narrative_Electrical.pdf PDF
Attachment 9 - 05_Narrative_Fire Protection.pdf PDF
Attachment 6 - 01_Narrative_Architectural.pdf PDF
Attachment 2 - Contractor Safety - Environmental Form.docx DOCX document
Attachment 13- Wage Rates.pdf PDF
Attachment 8 - 03_Narrative_Structural (1).pdf PDF
Attachment 15 -Site Visit Instructions.docx DOCX document
36C77623R0150_1.docx DOCX document
Attachment 14 - EHRM FULL SET 07122023.pdf PDF
Attachment 4 - EHRM Columbus Drawings Part 2.pdf PDF
Attachment 12 - 09_Narrative_Telecom.pdf PDF
Attachment 16- VA Engineering Map.pdf PDF
Attachment 3 - EHRM Columbus Drawings Part 1.pdf PDF
Attachment 10 - 06_Narrative_Mechanical.pdf PDF
Attachment 1- Limitations on Subcontracting - Construction.docx DOCX document
Attachment 5 - EHRM Columbus Drawings Part 3.pdf PDF
Attachment 7 - 02_Narrative_Environmental.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BASE

PLAN

HEAD

METAL STUD U-TRACK (TOP AND BOTTOM)

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

BASE

PLAN

HEAD

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

BATT INSULATION WHERE

SPECIFIED IN SCHEDULE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

METAL RUNNER (FASTENED 24" O.C. MAX)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"TYPE X

5/8"TYPE X

2 LAYERS "TYPE X" GYPSUM BOARD

METAL RUNNER "J"

(FASTENED 24" O.C. MAX)

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

CH STUD PER SCHEDULE

ROOM SIDE SHAFT SIDE

1" TYPE X GYPSUM BOARD LINER PANEL

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"TYPE X

WIDTH

STUD 5/8"TYPE X

5/8" "TYPE X" GYPSUM

BOARD EACH SIDE

FINISH FLOOR

(REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

1"TYPE X

FIN FLOOR- (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

ROOM SIDE SHAFT SIDE

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

WALL FINISH

(REF: ROOM FINISH SCHEDULE)

ACTUAL

5/8"TYPE X

5/8"TYPE X

WIDTH

STUD

5/8"TYPE X

5/8"TYPE X

2 LAYERS "TYPE X" GYPSUM

BOARD EACH SIDE

FINISH FLOOR

(REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

BATT INSULATION

BASE

PLAN

HEAD

UNDERSIDE OF STRUCTURE

LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

WIDTH

ACTUAL

5/8"

WIDTH

STUD VARIES

WIDTH

STUD 5/8"

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE - (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

BATT INSULATION WHERE SPECIFIED

IN SCHEDULE

METAL STUD PER SCHEDULE

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

BATT INSULATION

FIRE RATED SEALANT

AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

FIRE RATED SEALANT AROUND PERIMETER

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

NOTE: INSULATED WALLS AROUND

RESTROOMS EXTEND OUTSIDE LAYER

OF GYPSUM BOARD TO DECK

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

WIDTH

STUD5/8"

WIDTH

ACTUAL

BATT INSULATION WHERE

SPECIFIED IN SCHEDULE

DIM DIMDIM DIMDIM DIM

DIM DIMDIM DIM

LINE OF CEILING

(REF: RCP FOR HEIGHT & TYPE)

DIM DIM DIM DIM

BASE

PLAN

HEAD

DIM DIM

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

1"TYPE XWIDTH

STUD

3/4"TYPE X

WIDTH

STUD

CH STUD PER SCHEDULE

METAL STUD PER SCHEDULE METAL STUD PER SCHEDULE

5/8" GYPSUM WALLBOARD

METAL STUD U-TRACK (TOP AND BOTTOM)

METAL STUD U-TRACK (TOP AND BOTTOM)

METAL STUD U-TRACK (TOP AND BOTTOM)

1" GYPSUM SHAFT LINER

METAL STUD U-TRACK (TOP AND BOTTOM)

UNDERSIDE OF STRUCTURE

LINE OF CEILING (REF: RCP FOR HEIGHT & TYPE)

WALL FINISH (REF: ROOM FINISH SCHEDULE)

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR (REF: ROOM FINISH SCHEDULE)

BASE (REF: ROOM FINISH SCHEDULE)

METAL STUD PER SCHEDULE

FIRE-RATED SEALANT AROUND PERIMETER

METAL STUD U-TRACK (TOP AND BOTTOM)

1. NOT ALL WALL TYPES MAY BE USED.

2. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.

3. REFER TO FINISH SCHEDULE AND INTERIOR ELEVATIONS FOR LOCATIONS OF ALL WALL TILE.

PROVIDE AND INSTALL CEMENTITIOUS BACKER BOARD IN LIEU OF GYP. BD. AT ALL SCHEDULED TILE LOCATIONS. UNLESS NOTED OTHERWISE, TILE SHALL BE INSTALLED PER TILE COUNCIL OF

AMERICA LATEST STANDARDS FOR EACH TYPE OF BACKING MATERIAL REPRESENTED IN

WALL/PARTITION.

4. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GYP. BD. WHICH EXTENDS A MINIMUM OF

6" ABOVE THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY THE

ARCHITECT.

5. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL

ALIGN ACROSS VOIDS AND JOINTS.

6. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED

OTHERWISE) WHERE GYP. BD. CONTINUES ABOVE CEILING AND ABOVE THE CEILING LEVEL UP

TO THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER BEADS

MINIMUM FLOOR TO CEILING. ALL PENETRATIONS IN GYP. BD. CONSTRUCTION ABOVE FINISHED

CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND FIRE STOPPING

TAPE/CAULK AT ALL RATED PARTITIONS.

7. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE

OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS NOTED OTHERWISE, SHALL

EXTEND ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.

8. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE

SUPPORTED BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.

9. COORDINATE WITH MILLWORK DRAWINGS FOR PLACEMENT OF BLOCKING IN WALLS/PARTITIONS.

ALL WOOD BLOCKING IS TO BE FIRE RETARDANT TREATED.

10. IMPACT RESISTANT GYP. BD., WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND LOCKERS.

11. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.

GENERAL PARTITION NOTES

BASIC PARTITION

ASSEMBLY CATEGORY

FRAMING UNIT

SIZE CATEGORY

PARTITION TAG

PARTITION

PER PLAN

TYPICAL PARTITION TAG A3

UNDERSIDE OF STRUCTURE

FIRE RATED SEALANT

AROUND PERIMETER

DIM DIM

DEFLECTION TRACK

WHERE NEEDED

DEFLECTION TRACK AS REQUIRED

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :1

P

M

PARTITION TYPES

ZDL 7 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE001

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

K2 2 HR (U415/U438)

2 LAYERS 1/2" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X

GYPSUM BOARD ONE SIDE OF 2 1/2" CH METAL STUD AT 16" O.C.

3 1/2" 47 STC

K4 2 HR (U415/U438)

2 LAYERS 1/2" TYPE X GYPSUM BOARD EACH SIDE OF 4" CH METAL

STUD AT 16" O.C.

5" 47 STC

K6 2 HR (U415)

2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 4" CH METAL

STUD AT 16" O.C.

7 1/4" 47 STC

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

J2 2 HR (U411)

2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 2 1/2" METAL

STUD AT 16" O.C.

5" 51 STC

J3 2 HR (U404)

2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8" METAL

STUD AT 16" O.C.

6 1/8" 51 STC

J6 2 HR (U404)

2 LAYERS 5/8" TYPE X GYPSUM BOARD EACH SIDE OF 6" METAL

STUD AT 16" O.C.

8 1/2" 51 STC

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

H3 1 HR / SMOKE

5/8" TYPE X GYPSUM BOARD ON EACH SIDE OF 3 5/8" METAL STUD

AT 16" O.C.

4 7/8" 45 STC

H6 1 HR / SMOKE

5/8" TYPE X GYPSUM BOARD ON EACH SIDE OF 6" METAL STUD AT

16" O.C.

7 1/4" 45 STC

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

G2 1 HR (U415/U469)

5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X GYPSUM

BOARD OPPOSITE SIDE OF 2 1/2" CH METAL STUD AT 16" O.C. W/

BATT INSULATION

3 1/8" 45 STC

G4 1HR (U415/U438)

5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X GYPSUM

BOARD OPPOSITE SIDE OF 4" CH METAL STUD AT 16" O.C. W/ BATT

INSULATION

4 5/8" 45 STC

G6 1 HR (U415/U469)

5/8" TYPE X GYPSUM BOARD ONE SIDE & 1" TYPE X GYPSUM

BOARD OPPOSITE SIDE OF 6" CH METAL STUD SPACED AT 16" O.C.

W/ BATT INSULATION

6 5/8" 45 STC

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

F3 1 HR (U419)

5/8" TYPE X GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT

16" O.C.

4 7/8" 48 STC

F6 1 HR (U419)

5/8" TYPE X GYPSUM BOARD EACH SIDE OF 6" METAL STUD AT 16"

O.C.

7 1/4" 48 STC

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

E3 CARRIER

5/8" GYPSUM BOARD ONE SIDE OF (2) 3 5/8" METAL STUD AT 16"

O.C. WALLS W/ BATT INSULATION ONE SIDE

1'-8" --

E6 CARRIER

5/8" GYPSUM BOARD ONE SIDE OF (2) 6" METAL STUD AT 16" O.C.

WALLS W/ BATT INSULATION

2'-0 3/4" --

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

C2 NON-INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 2 1/2" METAL STUD AT 16" O.C. 3 3/4" --

C3 NON-INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT 16" O.C. 4 7/8" --

C6 NON-INSULATED 5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD AT 16" O.C. 7 1/4" --

D2 INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 2 1/2" METAL STUD AT 16" O.C.

W/ BATT INSULATION

3 3/4" --

D3 INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 3 5/8" METAL STUD AT 16" O.C.

W/ BATT INSULATION

4 7/8" --

D6 INSULATED

5/8" GYPSUM BOARD EACH SIDE OF 6" METAL STUD AT 16" O.C. W/

BATT INSULATION

7 1/4" --

TYPE

MARK

WALL

TYPE

WALL

DESCRIPTION

WALL

WIDTH

MIN.

STC

A1 NON-INSULATED

5/8" GYPSUM BOARD ONE SIDE 7/8" HAT CHANNEL SPACED AT 16"

O.C.

1 1/2" --

A2 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 2 1/2" METAL STUD AT 16" O.C. 3 1/8" --

A3 NON-INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD AT 16" O.C. 4 1/4" --

A6 NON- INSULATED 5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD AT 16" O.C. 6 5/8" --

B2 INSULATED

5/8" GYPSUM BOARD ONE SIDE OF 2 1/2" METAL STUD AT 16" O.C.

W/ BATT INSULATION

3 1/8" --

B3 INSULATED

5/8" GYPSUM BOARD ONE SIDE OF 3 5/8" METAL STUD AT 16" O.C.

W/ BATT INSULATION

4 1/4" --

B6 INSULATED

5/8" GYPSUM BOARD ONE SIDE OF 6" METAL STUD AT 16" O.C. W/

BATT INSULATION

6 5/8" --

No. REVISION DESCRIPTION DATE

AE401

AE401

AE401

AE402

AE401

AE402

AE402

AE401

AE401

AE401

AE402

AE402

AE402

AE401

157 SF

TELECOM

1A457

101 SF

TELECOM

1A024

103 SF

TELECOM

1A014

104 SF

TELECOM

1B006

91 SF

TELECOM

1B002

120 SF

TELECOM

1A106 96 SF

TELECOM

1B609

AE402

AE403

AE403

AE403

AE404

AE403

AE402

AE403

AE403

AE404

AE403

AE403

103 SF

TELECOM

2A018

101 SF

TELECOM

2B003

100 SF

TELECOM

2B310

91 SF

TELECOM

2B102

101 SF

TELECOM

2A004

120 SF

TELECOM

2A143

1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON

EACH FLOOR WITHIN EACH BUILDING.

2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW

CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.

GENERAL OVERALL PLAN NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :2

P

M

REFERENCE PLANS - BUILDING 1

ZDL 8 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE101

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1" = 40'-0"

BLDG 1 - LEVEL 1 - REFERENCE PLAN1

N

1" = 40'-0"

BLDG 1 - LEVEL 2 - REFERENCE PLAN4

AE404

AE404

AE404

AE404

AE404

AE404

100 SF

TELECOM

3A004

102 SF

TELECOM

3A015

115 SF

TELECOM

3A063

AE407

AE406

1067 SF

SERVER/MAIN

TELECOM

4A201

119 SF

TELECOM

4A041

AE405

AE405

AE405

AE405

105 SF

TELECOM

AE405

10AE405

56 SF

TELECOM

1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON

EACH FLOOR WITHIN EACH BUILDING.

2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW

CONSTRUCTION WITHIN AND ADJACENT TO EACH IN-SCOPE ROOM.

GENERAL OVERALL PLAN NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :2

P

M

REFERENCE PLANS - BLDG 1, ENERGY

BLDG, & ENGINEERING BLDG

ZDL 9 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE102

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1" = 40'-0"

BLDG 1 - LEVEL 3 - REFERENCE PLAN1

N

1" = 40'-0"

BLDG 1 - LEVEL 4 - REFERENCE PLAN3

N

1" = 40'-0"

BOILER PLANT - LEVEL 1 - REFERENCE PLAN2

N

1" = 40'-0"

ENGINEERING BUILDING - LEVEL 1 - REFERENCE PLAN4

157 SF

TELECOM

1A457

2'

-8

/2

F V

+/- 12'-5 1/2" FV

2.05 2.13

2.15

2.17

+/- 1'-2 3/4" FV

3/ 4"

F V

+/- 4" FV

+/- 3'-4" FV

2.18

101 SF

TELECOM

1A024

'-3

/2

F

V

+/- 12'-2" FV

2.05

2.13

2.15

2.17

+/- 3'-4" FV +/- 4'-5" FV

2.18

103 SF

TELECOM

1A014

+/- 8'-9" FV

1'

-8

/4

F V

2.05

2.13

2.15

2.17

'-4

F

V

'-2

/2

F V

2.18

157 SF

TELECOM

1A457

1A

2.17

26.04

TYP.

27.01

4"

9.87

4'-1" 4'-2 1/2"

5' -1

5'

-1

101 SF

TELECOM

1A024

1A

2.17

27.01

26.04

26.04

4'-5"

9.87

3'-0"

1' -0

3'

-1

/2

103 SF

TELECOM

1A014

1A014

26.04

27.01

TYP.

2.17

9.87

1'-0"

3' -0

6'

-3

3'-7"

103 SF

TELECOM

1A014

2.16

2.16

103 SF

TELECOM

1A014

23.05

23.05

E Q

3'

-0

3' -0

3'

-0

E Q

EQ. EQ.

101 SF

TELECOM

1A024

2.16 2.16

101 SF

TELECOM

1A02423.05

23.05

2'-0" 3'-0" 3'-0" 3'-0" 1'-2"

E Q

E

Q

157 SF

TELECOM

1A457

2.16

157 SF

TELECOM

1A457

EQ. 4'-0" EQ.

E Q

7'

-0

E Q

23.05

23.05

120 SF

TELECOM

1A106

EQ. 6'-0" EQ.

E Q

5'

-4

E Q

23.05

23.05

120 SF

TELECOM

1A106

2.16

2.16

120 SF

TELECOM

1A106

+/- 13'-3 1/2" FV

'-0

F

V

2.05

2.13

2.17

+/- 3'-4" FV

+/- 1'-0" FV

2.15

2.18

120 SF

TELECOM

1A106

1A

27.01

26.04

TYP.

2.17

1'-0"

9.8726.04

TYP.

1' -1

0" 3'

-0

3'-0" 7'-9 1/2"

SPOT ELEVATION HEIGHT,

ABOVE FINISH FLOOR

00'-00"

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

AND SALVAGED FOR

REINSTALLATION

EXISTING GYPSUM BOARD

CEILING

EXISTING 2 x 2 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

DEMOLITION REFELCTED CEILING PLAN LEGEND

EXISTING 2' x 4' ACOUSTICAL

CEILING TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

EXISTING RETURN AIR GRILLE

TO BE DEMOLISHED; REF

MECHANICAL

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED;

REF MECHANICAL

EXISTING EXHAUST AIR

GRILLE TO BE DEMOLISHED;

REF MECHANICAL

AREA NOT IN SCOPE

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING 2 x 2 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING DIFFUSER TO

REMAIN; REF MECHANICAL

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

6. EACH TELECOM ROOM TO HAVE NO CEILING. CONTRACTOR TO PRESERVE EXISTING FIRE

SUPPRESSION SYSTEMS.

GENERAL PLAN NOTES

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE; REF

ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

2 x 4 LIGHT FIXTURE; REF

ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

NEW RETURN AIR GRILLE;

REF MECHANICAL

NEW SUPPLY AIR DIFFUSER;

REF MECHANICAL

NEW EXHAUST AIR GRILLE;

REF MECHANICAL

SUSPENDED LIGHT FIXTURE;

REF ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DIFFUSER; REF

MECHANICAL

EXISTING DOOR, FRAME AND

HARDWARE TO BE

DEMOLISHED

DEMOLITION FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

EXISTING PARTITION TO BE

DEMOLISHED

EXISTING PARTITION TO

REMAIN

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DOOR & FRAME TO

REMAIN

EXISTING WINDOW & FRAME

TO REMAIN

EXISTING WINDOW & FRAME

TO BE DEMOLISHED

ICRA CONSTRUCTION

BARRIER AND

CONSTRUCTION ACCESS

EXISTING 1 HR PARTITION

TO REMAIN

DEMOLISH EXISTING

FLOORING TO EXTENT

INDICATED

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN

INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES

4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND

MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR

DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO

BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER

GENERAL DEMOLITION NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

CONTROLLED UNCLASSIFED INFORMATION (CUI)

CONTROLLED UNCLASSIFED INFORMATION (CUI)

C O

N T

R O

L L

E D

U N

C L

A S

S

IF

E D

I N

F O

R M

A T

IO

N

C

U I)

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :3

P

M

ENLARGED PLANS - BLDG 1 - LEVEL 1

ZDL 10 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE401

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A457 - DEMO13

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A024 - DEMO5

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A014 - DEMO1

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A457 - NEW14

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A024 - NEW6

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A014 - NEW2

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A014 - DEMO RCP3

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A014 - RCP4

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A024 - DEMO RCP7

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A024 - RCP8

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A457 - DEMO RCP15

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A457 - RCP16

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A106 - RCP12

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1A106 - DEMO RCP11

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A106 - DEMO9

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1A106 - NEW10

KEYNOTE LEGEND

2.05 DEMOLISH EXISTING DOOR AND FRAME IN ITS ENTIRETY

2.13 DEMOLISH EXISTING FLOORING AND BASE AND PREPARE SUBSURFACE FLOORING FOR NEW

TILE INSTALLATION

2.15 REMOVE EXISTING TELECOM AND ELECTRICAL EQUIPMENT PER ELECTRICAL AND TELECOM

DRAWINGS.

2.16 REMOVE EXISTING MECHANICAL EQUIPMENT PER MECHANICAL DRAWINGS.

2.17 EXISTING GROUND BAR TO REMAIN; SEE ELECTRICAL DRAWINGS.

2.18 PATCH AND REPAIR WALLS FOR PREPARATION OF NEW FINISH AFTER REMOVAL OF

EXISTING EQUIPMENT.

9.87 FLOOR FINISH AS SCHEDULED.

23.05 WALL-MOUNTED DUCTLESS SPLIT UNIT, SEE MECHANICAL DRAWINGS

26.04 PANEL LOCATION, SEE ELECTRICAL DRAWINGS

96 SF

1B609

2.05

2.13

2.15

2.17

+/- 9'-11 1/2" FV

0'

-0

F V

+/- 2'-1" FV

+/- 1'-3 1/4" FV

'-7

/2

F

V

+/- 1 3/4" FV

+/- 3'-4" FV

2.18

96 SF

TELECOM

1B609

1B

27.01

TYP

2.17

26.04

26.04

1 3/4"

9.87

3'-0"4'-5"

1' -0

3'

-2

96 SF

TELECOM

1B609

96 SF

TELECOM

1B609 23.05

23.05

3'-1" 5'-8" 1'-3"

2' -3

4'

-1

3' -8

91 SF

TELECOM

1B002

1B

27.01

2.17

26.04

TYP

2'-4"

9.87

1'-10 1/2"3'-0"

3' -1

1/

2" 3'

-1

1/ 2"

91 SF

TELECOM

1B002

2.05

2.13

2.15

2.17

+/- 9'-0 1/4" FV

'-9

/2

F

V

0' -4

F

V

+/- 1'-3 1/2" FV

+/- 3'-4" FV +/- 2'-4" FV

2.18

104 SF

TELECOM

1B006

2'

-3

/2

F V

+/- 8'-5 1/2" FV

2.05

2.13

2.15

2.17

+/- 3'-4" FV

+/- 2'-6 3/4" FV

2.18

104 SF

TELECOM

1B006

1B

2.17

27.01

TYP

26.04

TYP

9.87

1'-1"3'-2 1/2"

3' -8

6'

-1

104 SF

TELECOM

1B006

104 SF

TELECOM

1B006

E Q

3'

-0

3' -0

3'

-0

E Q

EQ. EQ.

23.05

23.05

91 SF

TELECOM

1B002

E Q

4'

-6

E Q

EQ. 4'-0" EQ.

23.05

23.05

91 SF

TELECOM

1B002

101 SF

TELECOM

2A004

+/- 12'-1 1/2" FV

'-3

/2

F

V

2.05

2.13

2.15

2.17

+/- 4'-4 3/4" FV +/- 3'-4" FV

2.18

101 SF

TELECOM

2A004

2A

2.17

26.04

27.01

TYP

9.87

1' -0

3'

-1

/2

3'-0"6'-7 1/2"

101 SF

TELECOM

2A004

2.162.16

101 SF

TELECOM

2A004

EQ. 3'-0" 3'-0" 3'-0" EQ.

23.05

23.05

4' -2

E

Q

SPOT ELEVATION HEIGHT,

ABOVE FINISH FLOOR

00'-00"

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

AND SALVAGED FOR

REINSTALLATION

EXISTING GYPSUM BOARD

CEILING

EXISTING 2 x 2 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

DEMOLITION REFELCTED CEILING PLAN LEGEND

EXISTING 2' x 4' ACOUSTICAL

CEILING TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

EXISTING RETURN AIR GRILLE

TO BE DEMOLISHED; REF

MECHANICAL

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED;

REF MECHANICAL

EXISTING EXHAUST AIR

GRILLE TO BE DEMOLISHED;

REF MECHANICAL

AREA NOT IN SCOPE

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING 2 x 2 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING DIFFUSER TO

REMAIN; REF MECHANICAL

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

6. EACH TELECOM ROOM TO HAVE NO CEILING. CONTRACTOR TO PRESERVE EXISTING FIRE

SUPPRESSION SYSTEMS.

GENERAL PLAN NOTES

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE; REF

ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

2 x 4 LIGHT FIXTURE; REF

ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

NEW RETURN AIR GRILLE;

REF MECHANICAL

NEW SUPPLY AIR DIFFUSER;

REF MECHANICAL

NEW EXHAUST AIR GRILLE;

REF MECHANICAL

SUSPENDED LIGHT FIXTURE;

REF ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DIFFUSER; REF

MECHANICAL

EXISTING DOOR, FRAME AND

HARDWARE TO BE

DEMOLISHED

DEMOLITION FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

EXISTING PARTITION TO BE

DEMOLISHED

EXISTING PARTITION TO

REMAIN

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DOOR & FRAME TO

REMAIN

EXISTING WINDOW & FRAME

TO REMAIN

EXISTING WINDOW & FRAME

TO BE DEMOLISHED

ICRA CONSTRUCTION

BARRIER AND

CONSTRUCTION ACCESS

EXISTING 1 HR PARTITION

TO REMAIN

DEMOLISH EXISTING

FLOORING TO EXTENT

INDICATED

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN

INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES

4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND

MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR

DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO

BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER

GENERAL DEMOLITION NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

CONTROLLED UNCLASSIFED INFORMATION (CUI)

CONTROLLED UNCLASSIFED INFORMATION (CUI)

C O

N T

R O

L L

E D

U N

C L

A S

S

IF

E D

I N

F O

R M

A T

IO

N

C

U I)

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :4

P

M

ENLARGED PLANS - BLDG 1 - LEVEL 1 &

ZDL 11 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE402

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B609 - DEMO9

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B609 - NEW10

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B609 - DEMO RCP11

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B609 - RCP12

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B002 - NEW2

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B002 - DEMO1

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B006 - DEMO5

N

1/4" = 1'-0" 1/ AE101

BLDG 1 - LEVEL 1 - 1B006 - NEW6

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B006 - DEMO RCP7

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B006 - RCP8

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B002 - RCP4

N

1/4" = 1'-0"

BLDG 1 - LEVEL 1 - 1B002 - DEMO RCP3

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A004 - DEMO13

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A004 - NEW14

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A004 - DEMO RCP15

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A004 - RCP16

KEYNOTE LEGEND

2.05 DEMOLISH EXISTING DOOR AND FRAME IN ITS ENTIRETY

2.13 DEMOLISH EXISTING FLOORING AND BASE AND PREPARE SUBSURFACE FLOORING FOR NEW

TILE INSTALLATION

2.15 REMOVE EXISTING TELECOM AND ELECTRICAL EQUIPMENT PER ELECTRICAL AND TELECOM

DRAWINGS.

2.16 REMOVE EXISTING MECHANICAL EQUIPMENT PER MECHANICAL DRAWINGS.

2.17 EXISTING GROUND BAR TO REMAIN; SEE ELECTRICAL DRAWINGS.

2.18 PATCH AND REPAIR WALLS FOR PREPARATION OF NEW FINISH AFTER REMOVAL OF

EXISTING EQUIPMENT.

9.87 FLOOR FINISH AS SCHEDULED.

23.05 WALL-MOUNTED DUCTLESS SPLIT UNIT, SEE MECHANICAL DRAWINGS

101 SF

2B003

1'

-1

1/ 2"

F V

+/- 8'-5 3/4" FV

2.05

2.13

2.15

+/- 3'-4" FV

+/- 2'-6 3/4" FV

2.17

2.18

101 SF

TELECOM

2B003

2B

2'-7"

26.04 2.17

27.01

TYP

9.87

3'-4"1'-0"

6' -4

/2

3'

-0

91 SF

TELECOM

2B102

+/- 8'-11" FV

0'

-6

/4

F V

2.13

2.15

'-1

F

V

+/- 1'-4 1/2" FV

2.18

91 SF

TELECOM

2B102

26.0426.04

TYP

27.01

9.87

3'-5"1'-4"

5' -1

3'

-0

101 SF

TELECOM

2B003

EQ. EQ.

2.20

23.05

23.05

E Q

3'

-0

3' -0

3'

-0

E Q

101 SF

TELECOM

2B003

91 SF

TELECOM

2B102

TELECOM

2B102

EQ. EQ.

E Q

2'

-6

2' -6

2'

-6

E Q

23.05

23.05

120 SF

TELECOM

2A143

2.16

120 SF

TELECOM

2A143

E Q

E

Q

EQ. 3'-0" 3'-0" 3'-0" EQ.

23.05

23.05

120 SF

TELECOM

2A143

+/- 13'-3 1/4" FV

'-0

/4

F

V

2.05

2.13

2.15

2.17

+/- 3'-4" FV

+/- 2'-9 3/4" FV

2.18

120 SF

TELECOM

2A143

2A

2.17

27.01

9.87

3' -1

1/

2" 1'

-0

7'-9 1/2"3'-0"

103 SF

TELECOM

2A018

+/- 8'-9" FV

1'

-8

/4

F V

2.05 2.13

2.15

2.17

'-4

F

V

'-2

/2

F V

2.18

103 SF

TELECOM

2A018

2A018

26.04

27.01

TYP

TYP

2'-2" 2'-2 3/4"

9.87

1'-0"3'-7"

6' -3

3'

-0

103 SF

TELECOM

2A018

2.16

2.16

103 SF

TELECOM

2A018

E Q

3'

-0

3' -0

3'

-0

E Q

23.05

23.05

2.20

EQ. EQ.

SPOT ELEVATION HEIGHT,

ABOVE FINISH FLOOR

00'-00"

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

AND SALVAGED FOR

REINSTALLATION

EXISTING GYPSUM BOARD

CEILING

EXISTING 2 x 2 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

DEMOLITION REFELCTED CEILING PLAN LEGEND

EXISTING 2' x 4' ACOUSTICAL

CEILING TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

EXISTING RETURN AIR GRILLE

TO BE DEMOLISHED; REF

MECHANICAL

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED;

REF MECHANICAL

EXISTING EXHAUST AIR

GRILLE TO BE DEMOLISHED;

REF MECHANICAL

AREA NOT IN SCOPE

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING 2 x 2 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING DIFFUSER TO

REMAIN; REF MECHANICAL

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

6. EACH TELECOM ROOM TO HAVE NO CEILING. CONTRACTOR TO PRESERVE EXISTING FIRE

SUPPRESSION SYSTEMS.

GENERAL PLAN NOTES

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE; REF

ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

2 x 4 LIGHT FIXTURE; REF

ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

NEW RETURN AIR GRILLE;

REF MECHANICAL

NEW SUPPLY AIR DIFFUSER;

REF MECHANICAL

NEW EXHAUST AIR GRILLE;

REF MECHANICAL

SUSPENDED LIGHT FIXTURE;

REF ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DIFFUSER; REF

MECHANICAL

EXISTING DOOR, FRAME AND

HARDWARE TO BE

DEMOLISHED

DEMOLITION FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

EXISTING PARTITION TO BE

DEMOLISHED

EXISTING PARTITION TO

REMAIN

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DOOR & FRAME TO

REMAIN

EXISTING WINDOW & FRAME

TO REMAIN

EXISTING WINDOW & FRAME

TO BE DEMOLISHED

ICRA CONSTRUCTION

BARRIER AND

CONSTRUCTION ACCESS

EXISTING 1 HR PARTITION

TO REMAIN

DEMOLISH EXISTING

FLOORING TO EXTENT

INDICATED

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN

INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES

4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND

MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR

DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO

BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER

GENERAL DEMOLITION NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

CONTROLLED UNCLASSIFED INFORMATION (CUI)

CONTROLLED UNCLASSIFED INFORMATION (CUI)

C O

N T

R O

L L

E D

U N

C L

A S

S

IF

E D

I N

F O

R M

A T

IO

N

C

U I)

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :5

P

M

ENLARGED PLANS - BLDG 1 - LEVEL 2

ZDL 12 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE403

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B003 - DEMO9

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B003 - NEW10

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B102 - DEMO13

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B102 - NEW14

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B003 - RCP12

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B003 - DEMO RCP11

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B102 - DEMO RCP15

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B102 - RCP16

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A143 - DEMO RCP7

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A143 - RCP8

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A143 - DEMO5

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A143 - NEW6

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A018 - DEMO1

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2A018 - NEW2

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A018 - DEMO RCP3

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2A018 - RCP4

KEYNOTE LEGEND

2.05 DEMOLISH EXISTING DOOR AND FRAME IN ITS ENTIRETY

2.13 DEMOLISH EXISTING FLOORING AND BASE AND PREPARE SUBSURFACE FLOORING FOR NEW

TILE INSTALLATION

2.15 REMOVE EXISTING TELECOM AND ELECTRICAL EQUIPMENT PER ELECTRICAL AND TELECOM

DRAWINGS.

2.16 REMOVE EXISTING MECHANICAL EQUIPMENT PER MECHANICAL DRAWINGS.

2.17 EXISTING GROUND BAR TO REMAIN; SEE ELECTRICAL DRAWINGS.

2.18 PATCH AND REPAIR WALLS FOR PREPARATION OF NEW FINISH AFTER REMOVAL OF

EXISTING EQUIPMENT.

2.20 EXISTING MECHANICAL EQUIPMENT TO REMAIN, SEE MECHANICAL DRAWINGS.

9.87 FLOOR FINISH AS SCHEDULED.

23.05 WALL-MOUNTED DUCTLESS SPLIT UNIT, SEE MECHANICAL DRAWINGS

115 SF

3A063

8' -8

/2

F

V

13'-3" FV

2.05

2.13

2.15

+/- 3'-4" FV +/- 2'-10" FV

2.17

2.18

115 SF

TELECOM

3A063

3A

2'-10"2.17

9.87

3'-0" 7'-9"

3' -0

1'

-6

/2

TELECOM

3A004

+/- 12'-2" FV

'-2

/4

F

V

2.05

2.13

2.15

+/- 2'-2" FV +/- 3'-8" FV

2.17

2.18

100 SF

TELECOM

3A004

3A

2.17

26.04

27.01

2'-2"

9.87

26.04 26.04

1' -0

3'-0"6'-8"

3' -0

/2

102 SF

TELECOM

3A015

1'

-7

/2

F V

+/- 8'-9 1/4" FV

2.05 2.13

2.15+

'-4

F

V

'-0

/4

F V

2.17

2.18

102 SF

TELECOM

3A015

3A015

26.04 2.17

27.01

9.87

1'-0"3'-7"

6' -1

/2

3'

-0

100 SF

TELECOM

3A004 2.16

2.16

100 SF

TELECOM

3A004

EQ. 3'-0" 3'-0" 3'-0" EQ.

E Q

E

Q

2.20

23.05

23.05

102 SF

TELECOM

3A015

2.16

2.16

102 SF

TELECOM

3A015

EQ. EQ.

E Q

3'

-0

3' -0

3'

-0

E Q

23.05

23.05

115 SF

TELECOM

3A063

EQ. 3'-0" 3'-0" 3'-0" EQ.

E Q

E

Q

23.05 23.05

115 SF

TELECOM

3A063

2.16

100 SF

TELECOM

2B310

EQ. 5'-6" EQ.

E Q

4'

-0

E Q

.23.05

100 SF

TELECOM

2B310

100 SF

TELECOM

2B310

2'

-7

F V

+/- 8'-0" FV

2.13

2.15

2.17

2.18

100 SF

TELECOM

2B310

2.17

26.04

27.01

9.87

23.04

1'-0" 2'-10"3' -0

SPOT ELEVATION HEIGHT,

ABOVE FINISH FLOOR

00'-00"

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

AND SALVAGED FOR

REINSTALLATION

EXISTING GYPSUM BOARD

CEILING

EXISTING 2 x 2 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

DEMOLITION REFELCTED CEILING PLAN LEGEND

EXISTING 2' x 4' ACOUSTICAL

CEILING TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

EXISTING RETURN AIR GRILLE

TO BE DEMOLISHED; REF

MECHANICAL

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED;

REF MECHANICAL

EXISTING EXHAUST AIR

GRILLE TO BE DEMOLISHED;

REF MECHANICAL

AREA NOT IN SCOPE

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING 2 x 2 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING DIFFUSER TO

REMAIN; REF MECHANICAL

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

6. EACH TELECOM ROOM TO HAVE NO CEILING. CONTRACTOR TO PRESERVE EXISTING FIRE

SUPPRESSION SYSTEMS.

GENERAL PLAN NOTES

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE; REF

ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

2 x 4 LIGHT FIXTURE; REF

ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

NEW RETURN AIR GRILLE;

REF MECHANICAL

NEW SUPPLY AIR DIFFUSER;

REF MECHANICAL

NEW EXHAUST AIR GRILLE;

REF MECHANICAL

SUSPENDED LIGHT FIXTURE;

REF ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DIFFUSER; REF

MECHANICAL

EXISTING DOOR, FRAME AND

HARDWARE TO BE

DEMOLISHED

DEMOLITION FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

EXISTING PARTITION TO BE

DEMOLISHED

EXISTING PARTITION TO

REMAIN

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DOOR & FRAME TO

REMAIN

EXISTING WINDOW & FRAME

TO REMAIN

EXISTING WINDOW & FRAME

TO BE DEMOLISHED

ICRA CONSTRUCTION

BARRIER AND

CONSTRUCTION ACCESS

EXISTING 1 HR PARTITION

TO REMAIN

DEMOLISH EXISTING

FLOORING TO EXTENT

INDICATED

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN

INSPECTED BY THE VA SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES

4. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

5. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND

MAINTAIN FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR

DUE TO EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

6. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

7. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO

BE PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER

GENERAL DEMOLITION NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH FIRM REG. NO. 20314270 EXP. 06/30/2023

ENGR FIRM REG. NO. 06253 EXP. 06/30/2024

FIRE PROTECTION ENGR

POOLE FIRE PROTECTION

19910 WEST 161ST ST.

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT (RSH)

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

STRUCT ENGR

STAND (SEI)

8234 ROBINSON ST

OVERLAND PARK, KS 66204

(913) 214-2169

COMMISSIONING

ES2

13401 N SANTE FE AVE

OKLAHOMA CITY, OK

(405) 528-4500

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

CONTROLLED UNCLASSIFED INFORMATION (CUI)

CONTROLLED UNCLASSIFED INFORMATION (CUI)

C O

N T

R O

L L

E D

U N

C L

A S

S

IF

E D

I N

F O

R M

A T

IO

N

C

U I)

TELECOMMUNICATION

ASPEN COMMUNICATIONS

7 KIJI-DAVA CIRCLE, STE A

PRESCOTT, AZ 86301

(928) 774-0992

MECH / ELEC / PLUMB ENGR

SPUR DESIGN

2519 MADISON AVE, STE 100

KANSAS CITY, MO 64108

(913) 369-7200

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

PHYSICAL SECURITY

/3

/2

:1 :5

P

M

ENLARGED PLANS - BLDG 1 - LEVEL 2 &

ZDL 13 OF 78BKM

FINAL BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES - TIER 2

06/02/2023

757-22-705

CHALMERS P. WYLIE VA

420 NORTH JAMES ROAD

COLUMBUS, OHIO 43219-1834

AE404

BLDG 1, ENERGY BLDG, & ENGR. BLDG

SPUR #: 1791.19

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A063 - DEMO13

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A063 - NEW14

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A004 - DEMO5

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A004 - NEW6

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A015 - DEMO9

N

1/4" = 1'-0" 1/ AE102

BLDG 1 - LEVEL 3 - 3A015 - NEW10

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A004 - DEMO RCP7

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A004 - RCP8

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A015 - DEMO RCP11

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A015 - RCP12

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A063 - RCP16

N

1/4" = 1'-0"

BLDG 1 - LEVEL 3 - 3A063 - DEMO RCP15

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B310 - RCP4

N

1/4" = 1'-0"

BLDG 1 - LEVEL 2 - 2B310 - DEMO RCP3

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B310 - DEMO1

N

1/4" = 1'-0" 4/ AE101

BLDG 1 - LEVEL 2 - 2B310 - NEW2

KEYNOTE LEGEND

2.05 DEMOLISH EXISTING DOOR AND FRAME IN ITS ENTIRETY

2.13 DEMOLISH EXISTING FLOORING AND BASE AND PREPARE SUBSURFACE FLOORING FOR NEW

TILE INSTALLATION

2.15 REMOVE EXISTING TELECOM AND ELECTRICAL EQUIPMENT PER ELECTRICAL AND TELECOM

DRAWINGS.

2.16 REMOVE EXISTING MECHANICAL EQUIPMENT PER MECHANICAL DRAWINGS.

2.17 EXISTING GROUND BAR TO REMAIN; SEE ELECTRICAL DRAWINGS.

2.18 PATCH AND REPAIR WALLS FOR PREPARATION OF NEW FINISH AFTER REMOVAL OF

EXISTING EQUIPMENT.

2.20 EXISTING MECHANICAL EQUIPMENT TO REMAIN, SEE MECHANICAL DRAWINGS.

9.87 FLOOR FINISH AS SCHEDULED.

23.04 MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS

23.05 WALL-MOUNTED DUCTLESS SPLIT UNIT, SEE MECHANICAL DRAWINGS

119 SF

4A041

+/- 13'-3 1/2" FV

'-0

/4

F

V

2.05

2.13

2.15

+/- 3'-4" FV

+/- 1'-0" FV

2.17

2.18

119 SF

TELECOM

4A041

4A

2.17

27.01

9.87 1'

-0

3' -1

0"

3'-0" 7'-9 1/2"

119 SF

TELECOM

4A041

2.162.16

119 SF

TELECOM

4A041

E Q

E

Q

EQ. 3'-0" 3'-0" 3'-0" EQ.

2.20

23.05

23.05

2.20

105 SF

TELECOM

'-8

F

V

+/- 13'-8" FV

2.05

2.13

2.15

'-4

F

V

/2

F V

2.18

105 SF

TELECOM

1/

2"

27.01

TYP26.04

9.87

1' -0

4'

-8

/2

5'-8"5'-6 1/2"

105 SF

TELECOM

EQ. 8'-6" EQ.

E Q

E

Q

23.05

23.05

105 SF

TELECOM

104 2.16

56 SF

TELECOM

- 7

'-0

/4

F V

+/- 7'-11 1/2" FV

2.05 2.13

2.15

+/- 3'-4" FV

2.18

56 SF

TELECOM

26.04

27.02

9.87

4' -6

56 SF

TELECOM

EQ.

EQ.

E Q

3'

-9

E Q

23.05

56 SF

TELECOM

2.16

SPOT ELEVATION HEIGHT,

ABOVE FINISH FLOOR

00'-00"

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

AND SALVAGED FOR

REINSTALLATION

EXISTING GYPSUM BOARD

CEILING

EXISTING 2 x 2 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE DEMOLISHED; REF

ELECTRICAL

DEMOLITION REFELCTED CEILING PLAN LEGEND

EXISTING 2' x 4' ACOUSTICAL

CEILING TO BE REMOVED AND

SALVAGED FOR

REINSTALLATION

EXISTING RETURN AIR GRILLE

TO BE DEMOLISHED; REF

MECHANICAL

EXISTING SUPPLY AIR

DIFFUSER TO BE DEMOLISHED;

REF MECHANICAL

EXISTING EXHAUST AIR

GRILLE TO BE DEMOLISHED;

REF MECHANICAL

AREA NOT IN SCOPE

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING 2 x 2 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING 2 x 4 LIGHT FIXTURE

TO BE REMOVED AND

RELOCATED; REF ELECTRICAL

EXISTING DIFFUSER TO

REMAIN; REF MECHANICAL

EXISTING 2' x 2' ACOUSTICAL

CEILING TO BE REMOVED

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE & DETAILS SHEET (AE601) FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. BLOCK OUT SLAB FOR PENETRATIONS SHALL BE 2" LARGER THAN DUCT SIZE TO ALLOW

TOLERANCE FOR DUCT PASSAGE AND FIRE SAFING. COORDINATE WITH MEP FOR DUCT SIZES.

5. FURR AROUND ALL COLUMN PROTRUSIONS AS NEEDED UNLESS NOTED OTHERWISE.

6. EACH TELECOM ROOM TO HAVE NO CEILING. CONTRACTOR TO PRESERVE EXISTING FIRE

SUPPRESSION SYSTEMS.

GENERAL PLAN NOTES

2' x 2' ACOUSTICAL CEILING

GYPSUM BOARD CEILING OR

SOFFIT

2 x 2 LIGHT FIXTURE; REF

ELECTRICAL

CEILING HEIGHT, ABOVE

FINISH FLOOR

2 x 4 LIGHT FIXTURE; REF

ELECTRICAL

00'-00"

REFLECTED CEILING PLAN LEGEND

2' x 4' ACOUSTICAL CEILING

NEW RETURN AIR GRILLE;

REF MECHANICAL

NEW SUPPLY AIR DIFFUSER;

REF MECHANICAL

NEW EXHAUST AIR GRILLE;

REF MECHANICAL

SUSPENDED LIGHT FIXTURE;

REF ELECTRICAL

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DIFFUSER; REF

MECHANICAL

EXISTING DOOR, FRAME AND

HARDWARE TO BE

DEMOLISHED

DEMOLITION FLOOR PLAN LEGEND

AREA NOT IN CONTRACT

EXISTING PARTITION TO BE

DEMOLISHED

EXISTING PARTITION TO

REMAIN

NOTE: ALL SYMBOLS MAY NOT BE USED.

EXISTING DOOR & FRAME TO

REMAIN

EXISTING WINDOW & FRAME

TO REMAIN

EXISTING WINDOW & FRAME

TO BE DEMOLISHED

ICRA CONSTRUCTION

BARRIER AND

CONSTRUCTION ACCESS

EXISTING 1 HR PARTITION

TO REMAIN

DEMOLISH EXISTING

FLOORING TO EXTENT

INDICATED

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT AREA HAS BEEN

INSPECTED BY THE VA SAFETY…