02_Hazardous Materials.pdf
PDF 671 KB Posted
- Attached to
- Y1DA--757-22-705 EHRM Infrastructure Upgrades - Columbus, OH - Tier 2 Construction (VA-22-00108764)
- Solicitation number
- 36C77623R0150
About this file
This document package includes construction drawings and specifications for hazardous materials abatement and infrastructure upgrades at the Chalmers P. Wylie VA Medical Center in Columbus, Ohio. The drawings outline the scope of work to remove approximately 150 square feet of presumed asbestos-containing roof materials from Building 1 and 10 square feet from the Energy Building to allow for new HVAC equipment. Additional work includes penetrating building elements as needed for mechanical, electrical and plumbing systems. Bidders must be licensed for asbestos abatement and provide wet hygiene stations. The related solicitation is for Tier 2 construction services under contract number 36C77623R0150, issued by the Department of Veterans Affairs Technology Acquisition Center Austin. The award date is unspecified.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing #
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
FIRE PROTECTION ENGR
POOLE FIRE PROTECTION
19910 WEST 161ST ST.
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT (RSH)
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
STRUCT ENGR
STAND (SEI)
8234 ROBINSON ST
OVERLAND PARK, KS 66204
(913) 214-2169
COMMISSIONING
ES2
13401 N SANTE FE AVE
OKLAHOMA CITY, OK
(405) 528-4500
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
TELECOMMUNICATION
ASPEN COMMUNICATIONS
7 KIJI-DAVA CIRCLE, STE A
PRESCOTT, AZ 85712
(928) 774-0992
MECH / ELEC / PLUMB ENGR
SPUR DESIGN
11020 KING STREET, STE 350
OVERLAND PARK, KS 66210
(913) 369-7200
P
M
BUILDING 1 - ROOF - ENVIRONMENTAL
HAZARDS
CD
JR
EHRM INFRASTRUCTURE
UPGRADE - TIER 2
06/02/2023
757-22-705
CHALMERS P. WYLIE VA
420 NORTH JAMES ROAD
COLUMBUS, OHIO 43219-1834
HA100
SPUR #: 1791.19
No. REVISION DESCRIPTION DATE
HAZARDOUS MATERIALS KEYNOTES
REMOVE SPOT AREAS OF PRESUMED ASBESTOS ROOF MATERIALS USING MANUAL MEANS WITHIN AN OUTDOOR
REGULATED AREA. COORDINATE AND REMOVE IN EXTENTS TO ALLOW FOR NEW MINI-SPLIT SYSTEM INSTALLATION
IN THE FOLLOWING APPROXIMATE QUANTITIES;
BUILDING 1: LEVEL 3 AND 2 ROOFS - 150 SF TOTAL, PENETRATIONS NECESSARY FOR BASE RAILS, CURBS, PIPE
STANDS, CONDUITS AND OTHER SYSTEM ELEMENTS AND 6 PROJECT MOBILIZATIONS.
ENERGY BUILDING: LEVEL 2 ROOFS, 10 SF TOTAL, PENETRATIONS NECESSARY FOR BASE RAILS, CURBS, PIPE
STANDS, CONDUITS AND OTHER SYSTEM ELEMENTS AND 1 PROJECT MOBILIZATION. WORK TO BE PERFORMED BY A
LICENSED ABATEMENT CONTRACTOR. PROVIDE WET HYGIENE STATIONS ASSOCIATED WITH WORK.
A1
GENERAL SHEET NOTES
LEAD LINED DRYWALL MAY BE PRESENT IN AREAS AROUND RADIOLOGICAL DEVICES, DO NOT DISTURB AND PROTECT AS
NECESSARY. USING EXISTING SYSTEM ELEMENT PATHWAYS AND FIXTURE PENETRATIONS IN RADIOLOGICAL ISOLATION ZONES
IF ENCOUNTERED.
OSHA CONSTRUCTION INDUSTRY STANDARD, 29 CFR 1926.62 (LEAD) DOES APPLY TO ANY EMPLOYEE INVOLVED WITH
DEMOLITION / RENOVATION WORK THAT WILL BE PERFORMED IN BUILDINGS. THE CONSTRUCTION INDUSTRY STANDARD
REGULATES OCCUPATIONAL EXPOSURES TO AIRBORNE LEAD, WHICH INCLUDES DEMOLITION OR SALVAGE OF STRUCTURES
WHERE LEAD OR MATERIALS CONTAINING LEAD ARE PRESENT, AND ANY AMOUNT OF LEAD PRESENT IN PAINTED SURFACES, INCLUDING THOSE WHICH FALL BELOW THE ABOVE DEFINITION OF LEAD-BASED PAINT, COULD RESULT IN REGULATED
OCCUPATIONAL EXPOSURES AND SHOULD THEREFORE BE MONITORED ACCORDING TO OSHA 1926.62 WHENEVER MATERIALS
ARE DISTURBED IN A MANNER THAT COULD RESULT IN EXPOSURE TO AIRBORNE LEAD PARTICULATES, IT IS THE
RESPONSIBILITY OF THE EMPLOYER TO COMPLY WITH OSHA 1926.62 TO PROTECT THE SAFETY AND HEALTH OF HIS/HER
EMPLOYEES INVOLVED IN THE DEMOLITION OR RENOVATION OF THESE BUILDINGS.
DN
NOT TO SCALE
BUILDING 1 - LEVEL 4 ROOF
NOT TO SCALE
BUILDING 1 - LEVEL 3 ROOF
NOT TO SCALE
ENERGY BUILDING - LEVEL 2 ROOF
A1
A1
A1
A1
A1
A1
BID DOCUMENTS
| Sheets and Views |
| Model |
File details come from the government source that posted it. Updated .