This document is a technical specification section (Section 07 40 00) for siding panels for the Fargo Veterans Affairs Healthcare System (VAHCS) project located in Fargo, North Dakota. The specification covers uninsulated metal wall panels for a site preparation project with a bid document date of 1-22-2025 and an anticipated completion date of 08/29/2025. The specified metal wall panels are from AEP Span, with a "Light Stone" color, utilizing 24-gauge galvanized steel with a DuraTech® 5000 Polyvinylidine Fluoride exterior finish. Key requirements include a minimum 30% postconsumer recycled steel content, a 10-year warranty on panel finishes, and detailed installation instructions for fastening, flashing, and protecting the panels.

The specification mandates strict quality assurance, including manufacturer qualifications of at least five years of experience in metal panel fabrication and installer qualifications of three years of successful installation experience. Detailed submittal requirements include shop drawings, samples, fire test reports, and manufacturer certificates. Installation guidelines emphasize precise fastener placement, proper panel alignment, weather sealing, and protection against dissimilar metal interactions. The contractor must ensure complete weather tightness, properly seal cut edges, and maintain the integrity of the panel system's finish during and after installation.

View the file

Other files

File Type Posted
Attachment 0004d - PP-101 - PLUMBING PLANS - Lower Level Process Piping - 1 Page.pdf PDF
Attachment 0004i - Scope of Work Change Log - 1 Page.pdf PDF
Attachment 0004b - 17639 Narrative - Addendum 2 - 1 Page.pdf PDF
Attachment 0004g - 226719.16 - REVERSE-OSMOSIS WATER EQUIPMENT - 10 Pages.pdf PDF
Attachment 0004e - P-301 - PLUMBING RO FLOW DIAGRAM - 1 Page.pdf PDF
Attachment 0004c - 000110 TOC - 5 Pages.pdf PDF
Attachment 0004a - SOW - Perform Site Prep - Rev 3 - 12 Pages.pdf PDF
36C26325B0025 0004.docx DOCX document
Attachment 0004f - AAMI ST108-2023 Water for the processing of med devices - 102 Pages.pdf PDF
Attachment 0004h - 223111 - Water Softener - 10 Pages.pdf PDF
36C26325B0025 0003.docx DOCX document
Attachment 0002A - DBA Wage Rate ND20250013 August 28 2025 - 13 Pages.pdf PDF
36C26325B0025 0002.docx DOCX document
Attachment H - GI001 - 1 Page.pdf PDF
Attachment F - 092900 Gypsum Board - 8 Pages.pdf PDF
Attachment J - PP-103 - PLUMBING - PIPING - LOWER LEVEL RO TEMP TRAILER - 1 Page.pdf PDF
Attachment L - Site Visit Agenda - Site Prep for SPS Equipment - 2 Pages.pdf PDF
Attachment I - MH-104 - MECH LOWER LEVEL - HVAC - TEMPORARY TRAILER - 1 Page.pdf PDF
Attachment M - Site Visit Sign-in Sheet 8-15-2025 - 1 Page.pdf PDF
Attachment E - 092216 Non-Structural Metal Framing - 8 Pages.pdf PDF
Attachment B - SOW - Perform Site Prep V2 - 9 Pages.pdf PDF
Attachment G - AS501 - 1 Page.pdf PDF
Attachment C - 17639 Narrative - Addendum 1 - 1 Page.pdf PDF
Attachment K - S401- FRAMING DETIALS - 1 Page.pdf PDF
Attachment A - 437-CSI-241 Site Prep Questions and Answers - 7 Pages.pdf PDF
36C26325B0025 0001.docx DOCX document
Attachment C3 - Drawings-R1_Part3 - 437-CIS-241 - 26 Pages.pdf PDF
Attachment B2 - SPEC VOL II-R1 - 437-CIS-241 - 960 Pages.pdf PDF
Attachment B1 - SPEC VOL I-R1 - 437-CIS-241 - 593 Pages.pdf PDF
Attachment C4 - Drawings-R1_Part4 - 437-CIS-241 - 21 Pages.pdf PDF
Attachment C2 - Drawings-R1_Part2 - 437-CIS-241 - 21 Pages.pdf PDF
Attachment D1 - DBA Wage Rate ND20250013 7 31 2025 - 437-CIS-241 - 12 Pages.pdf PDF
Attachment C1 - Drawings-R1_Part1 - 437-CIS-241 - 16 Pages.pdf PDF
Attachment E1 - Limitations on Subcontracting - 3 Pages.pdf PDF
Attachment A1 - Statement of Work - 437-CIS-241 - 10 Pages.pdf PDF
Attachment C5 - Drawings-R1_Part5 - 437-CIS-241 - 20 Pages.pdf PDF
36C26325B0025_1.docx DOCX document
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Fargo VAHCS, Fargo ND VA Project 437-CSI-241 Perform Site Prep for SPS Equipment 1-22-2025 (AD-1 08/29/2025) 2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 1

SIDING PANELS

SECTION 07 40 00

SIDING PANELS

PART 1 - GENERAL

1.1 DESCRIPTION

A. This section specifies uninsulated metal wall panels as shown on contract documents.

1.2 RELATED WORK

A. Section 01 81 13, SUSTAINABLE CONSTRUCTION REQUIREMENTS: Sustainable

Design Requirements.

B. Section 07 21 13, THERMAL INSULATION: Rigid Insulation

C. Section 07 25 00, WEATHER BARRIERS: Sheet waterproofing.

D. Section 07 92 00, JOINT SEALANTS: Sealant.

1.3 QUALITY ASSURANCE

A. Manufacturer’s Qualifications: Provide metal wall panels products of a manufacturer regularly engaged for not less than five (5) years in the fabrication of metal panels of the type and design indicated.

B. Installer: A firm with three (3) years of successful experience with installation of roofing and siding panels of type and scope equivalent to Work of this Section. Submit installer qualifications.

1.4 SUBMITTALS

A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT

DATA, AND SAMPLES.

B. Sustainable Design Submittals, as described below:

1. Postconsumer recycled content as specified in PART 2 - PRODUCTS.

C. Samples: Metal panel, 152 mm (6 inch) square, showing finish, each color and texture.

D. Shop Drawings: Wall panels, showing details of construction and installation. Thickness and kind of material, closures, flashing, fastenings and related components and accessories. Show interfaces and relationships to work at other trades and continuity with adjacent thermal, weather, air and vapor barriers.

E. Manufacturer's Literature and Data: Wall panels

F. Fire Test Report: Report of fire test by recognized testing laboratory for fire rating specified, showing details of construction.

G. Manufacturer’s Certificates: Indicating manufacturer’s qualifications specified.

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 2

SIDING PANELS

H. Installer qualifications.

I. Manufacturer warranty.

1.5 QUALITY ASSURANCE

A. Approval by Contracting Officer Representative (COR) is required of products of proposed manufacturer.

B. Certify manufacturer has five (5) years continuous documented experience in fabrication of metal roofing and siding panels.

C. Source: For each material type required for work of this section, provide primary materials, which are products of one manufacturer.

Provide secondary or accessory materials, which are acceptable to manufacturers of primary materials.

D. Installer: A firm with a minimum of three (3) years’ experience in type of work required by this section and which is acceptable to manufacturers of primary materials.

1.6 WARRANTY

A. Construction Warranty: Comply with FAR clause 52.246-21 “Warranty of

Construction”.

B. Manufacturer Warranty: Manufacturer shall warranty their metal wall panels for a minimum of ten (5) years from the date of installation and final acceptance by the Government. Submit manufacturer warranty.

C. Warranty on Panel Finishes: Manufacturer’s shall warrant their and wall panel finish and provide standard agreement to repair finish or replace metal panels that show evidence of deterioration of factory-applied finishes within specified warranty period.

1. Exposed Panel Finish: Deterioration includes, but is not limited to, the following:

a. Color fading more than 5 Hunter units when tested according to

ASTM D2244.

b. Chalking in excess of a No. 8 rating when testing according to

ASTM D4214.

c. Cracking, checking, peeling, or failure of paint to adhere to bare metal.

2. Finish Warranty Period: 10 years from date of installation and final acceptance by the COR.

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 3

SIDING PANELS

1.7 APPLICABLE PUBLICATIONS

A. The publications listed below form a part of this specification to the extend referenced. The publications are referenced in the text by the basic designation only.

B. American Architecture Manufacturers Association (AAMA):

611-14 .................Anodized Architectural Aluminum

621-02 .................Voluntary Specifications for High Performance

Organic Coatings on Coil Coated Architectural

Hot Dipped Galvanized (HDG) and Zinc-Aluminum

Coated Steel Substrates

2605-13 ................Voluntary Specification, Performance

Requirements and Test Procedures for Superior

Performing Organic Coatings on Aluminum

Extrusions and Panels

C. American Iron and Steel Institute (AISI):

SG03-02 ................Cold-Formed Steel Design Manual

D. ASTM International (ASTM):

A463/A463M-15 ..........Steel Sheet, Cold-Rolled, Aluminum-Coated, by the Hot-Dip Process

A653/A653M-20 ..........Steel Sheet, Zinc-Coated (Galvanized), or Zinc-

Iron Alloy-Coated (Galvannealed) by the Hot-Dip

Process.

A924/A924M-19 ..........Steel Sheet, Metallic Coated by the Hot-Dip

Process

A1008/A1008M-18 ........Steel, Sheet, Cold-Rolled, Carbon, Structural, High Strength Low Alloy

B209-14 ................Aluminum and Aluminum Alloy Sheet and Plate

B209M-14 ...............Aluminum and Aluminum Alloy Sheet and Plate

(Metric)

C553-19 ................Mineral Fiber Blanket Thermal Insulation for

Commercial and Industrial Applications

C591-20. ...............Unfaced Preformed Rigid Cellular

Polyisocyanurate Thermal Insulation

C612-14(2019) ..........Mineral Fiber Block and Board Thermal

Insulation

C1396/C1396M-17 ........Gypsum Board

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 4

SIDING PANELS

D2244-16 ...............Calculation of Color Tolerances and Color

Differences from Instrumentally Measured Color

Coordinates

D4214-07(2015) .........Test Methods for Evaluating the Degree of

Chalking of Exterior Paint Films

E119-20 ................Fire Test of Building Construction and

Materials

E283-19 ................Test Method for Determining Rate of Air Leakage

Through Exterior Windows, Curtain Walls, and

Doors Under Specified Pressure Differences

Across the Specimen

E331-00(2016) ..........Test Method for Water Penetration of Exterior

Windows, Skylight, Doors, and Curtain Walls by

Uniform Static Air Pressure Difference

E1592-05(2017) .........Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by

Uniform Static Air Pressure Method

E1646-95(2018) .........Test Method for Water Penetration of Exterior

Metal Roof Panel Systems by Uniform Static Air

Pressure Difference

E1680-16 ...............Test Method for Rate of Air Leakage Through

Exterior Metal Roof Panel Systems

E1980-11(2019) .........Calculating Solar Reflectance Index of

Horizontal and Low-Sloped Opaque Surfaces

E2140-01(2017) .........Test Method for Water Penetration of Metal Roof

Panel Systems by Static Water Pressure Head

E. Cool Roof Rating Council (CRRC):

Standard-14

F. FM Global:

4471-10 ................Class 1 Panel Roofs

G. Underwriters Laboratories (UL):

580-05(R2018) ..........Tests for Uplift Resistance of Roof Assemblies

Fire Resistance Directory

PART 2 - PRODUCTS

2.1 METAL WALL PANELS

A. Basis of Design: AEP Span, a Division of ASC Prfiels, LLC. PBR Panel;

Color, “LIGHT STONE”.

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 5

SIDING PANELS

B. Single-skin exposed fastener metal wall panels applied as the exterior cladding over wall framing as shown and specified in 06 10 00 Rough

Carpentry with board insulation as specified in 07 21 13 Thermal

Insulation.

1. Water resistive barrier is required as specified in 07 25 00 Weather

Barriers.

2.2 SHEET STEEL

A. Minimum 24 gauge (0.60mm / 0.024 inch).

B. Steel, Sheet, Galvanized: ASTM A792.

1. Conform to ASTM A792, AZ50 (Zincalume/Galvalume)

2. Grade 50, galvanized coating conforming to ASTM A924/A924M, Class Z

275 G-90.

C. Recycled Content of Steel Products: Postconsumer recycled content not less than 30 percent.

2.3 EXTERIOR FINISH

A. DuraTech® 5000 (Polyvinylidine Fluoride), full 70% Kynar® 500/Hylar

5000® consisting of a baked-on 0.15-0.20 mil corrosion resistant primer and a baked-on 0.70-0.80 mil finish coat with a specular gloss of 10-

30% when tested in accordance with ASTM D-523- 89 at 60°.

2.4 INTERIOR FINISH

A. Primer Coat Material: Corrosion-resistant primer; primer coat dry film thickness: 0.15 mils; finish coat material: polyester paint, finish coat dry film thickness: 0.35 mils.

B. Color: Off white to light gray

2.5 FASTENERS

A. Fasteners of size, type and holding strength as recommended by panel manufacturer.

2.6 MEATAL WALL PANEL ACCESSORIES.

A. Metal Wall Panel Accessories, General: Provide complete metal wall panel assembly incorporating trim, copings, fasciae, parapet caps, soffits, sills, inside and outside corners, and miscellaneous flashings. Fabricate accessories in accordance with SMACNA Manual.

Provide manufacturer's factory-formed clips, shims, flashings, gaskets, lap strips, closure strips, and caps for a complete installation as required for the following

2.7 FABRICATION

A. General:

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 6

SIDING PANELS

1. Unless otherwise shown on drawings or specified herein, panels shall be full length. Fabricate flashings and accessories in longest practical lengths.

2. Fabricate wall louvers and frames used in conjunction with walls panels to be of same material, thickness and finish as exterior face sheets of wall system. Louver assembly to be designed and installed to prevent infiltration of water into structure.

PART 3 - EXECUTION

3.1 INSTALLATION

A. General: Install panels in accordance with the manufacturer's approved erection instructions and diagrams, except as specified otherwise.

B. Install panels in full and firm contact with supports and with each other at side and end laps.

C. Where panels are cut in the field, or where factory applied coverings or coatings are abraded or damaged in handling or installation, make finish repairs with material of the same type and color as the weather coating, before being installed.

D. Seal cut ends and edges, including those at openings through the sheets.

E. Correct defects or errors in the materials in a manner approved by the

COR.

F. Replace defective materials which cannot be corrected with nondefective material.

G. Provide molded closure strips where indicated and whenever sheets terminate with open ends after installation.

H. Wall Panels:

1. Apply panels with the configuration in a vertical position.

2. Provide panels in the longest obtainable lengths.

3. Seal side and end laps with joint sealing material.

4. Flash and seal walls at the base, at the top, around windows, door frames, framed louvers, and other similar openings. Install closure strips, flashings, and sealing material in an approved manner that will assure complete weather tightness.

I. Flashing:

1. Provide flashing and related closures and accessories in connection with the preformed metal panels as indicated and as necessary to provide a watertight installation.

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 7

SIDING PANELS

2. Install details of installation, which are not indicated, in accordance with the panel manufacturer's printed instruction and details, or the approved shop drawings.

3. Allow for expansion and contraction of flashing.

J. Fasteners:

1. Space fasteners in accordance with the manufacturer's recommendations, and as necessary to withstand the design loads indicated.

2. Install fasteners in valleys or crowns as recommended by the manufacturer of the panel being used.

3. Install fasteners in straight lines within a tolerance of 13 mm

(1/2-inch) in the length of a bay.

4. Drive exposed penetrating type fasteners normal to the surface, and to a uniform depth to seat gasketed washers properly, and drive so as not to damage factory applied coating.

5. Exercise care in drilling pilot holes for fastenings to keep drills perpendicular and centered in valleys, or crowns, as applicable.

After drilling, remove metal filings and burrs from holes prior to installing fasteners and washers. Do not torque fasteners to exceed values recommended by the manufacturer.

6. Remove panels deformed or otherwise damaged by over-torqued fastenings, and provide new panels.

7. Remove metal shavings and filings from roofs on completion to prevent rusting and discoloration of the panels.

3.2 ISOLATION OF ALUMINUM

A. Isolate aluminum in contact with or fastened to dissimilar metals other than stainless steel, white bronze, or other metal compatible with aluminum by one of the following:

1. Painting the dissimilar metal with a prime coat of Zinc-Molybdate followed by two coats of aluminum paint.

2. Placing a non-abrasive tape or gasket between the aluminum and the dissimilar metal.

B. Paint aluminum in contact with, or built into mortar, concrete, plaster, or other masonry materials with a coat of alkali-resistant bituminous paint.

2101 Elm Street North Bid Documents Fargo, ND 58102

07 40 00 - 8

SIDING PANELS

C. Paint aluminum in contact with wood or other absorptive materials that may become repeatedly wet, with two coats of bituminous paint, or two coats of aluminum paint. Seal joints with caulking material.

3.3 PROTECTION AND CLEANING

A. Protect panels and other components from damage during and after erection, and until project is accepted by the COR.

B. After completion of work, all exposed finished surfaces of panels are to be cleaned of soil, discoloration and disfiguration. Touch-up abraded surfaces of panels.

- - - E N D - - -

SECTION 07 40 00 SIDING PANELS
PART 1 - GENERAL
1.1 DESCRIPTION
1.2 RELATED WORK
1.3 QUALITY ASSURANCE
1.4 SUBMITTALS
1.5 QUALITY ASSURANCE
1.6 WARRANTY
1.7 APPLICABLE PUBLICATIONS
PART 2 - PRODUCTS
2.1 Metal wall panels
2.2 SHEET STEEL
2.3 Exterior Finish
2.5 FASTENERS
2.7 FABRICATION
PART 3 - EXECUTION
3.1 INSTALLATION
3.2 ISOLATION OF ALUMINUM
3.3 PROTECTION AND CLEANING