Attachment RFI 008.pdf
PDF 146 KB Posted
- Attached to
- Z1DA-- Renovate OR for Hybrid Installation
- Solicitation number
- 36C26126R0009
About this file
This is a Request for Information (RFI) document submitted by Strategic Industry regarding a VA construction project. The RFI, dated January 5, 2026, addresses a discrepancy concerning Door Opening 2A229B on the "Renovate OR for Hybrid Installation" project (Project No. 612A4-25-004, Solicitation No. 36C26126R0009). The contractor identified a conflict between the assigned Hardware Group 7B-1, which does not accommodate an automatic operator, and drawing A2.01, which specifies a hands-free wall actuator for an automatic operator at that opening.
The VA Project Manager responded on January 8, 2026, confirming that Door 2A229B will require a hand wave automatic operator. The revised Hardware Group 7B-1 specifications include: one continuous hinge HG315 AS, one push plate 73C, one pull plate 110x70B, one armor plate K1050 35" high SA CSK, one wall stop 401, two edge guards 310B, and one door operator and actuators per Section 08 71 13. The contractor contact is J. Rogers at (559) 419-9481 Ext. 212, with correspondence directed to the VA project officer at charee.harris@va.gov.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION (RFI) FORM
Contractor Name: Strategic Industry
Address: 170 Professional Center Dr. Suit A, Rohnert Park, CA, 94928
Phone and Email: (559) 419-9481 Ext. 212 & Jrogers@strategicindustry.us
Send to: charee.harris@va.gov
RFI
PROJECT NO.: 612A4-25-004 RFI NO.: 0005
PROJECT NAME: Renovate OR for
Hybrid Installation
DATE REQUESTED: 1/5/26
SOLICITATION
NO.:
36C26126R0009 REFERENCE:
DRAWING: SPECIFICATION
SECTION:
DESCRIPTION OF PROBLEM OR INFORMATION BEING REQUESTED
Opening 2A229B is currently assigned Hardware Group 7B-1. This hardware group is not configured to accommodate an automatic operator.
However, drawing A2.01 indicates HW (Hands-Free Wall Actuator for an Auto Operator) at this opening. This appears to conflict with the assigned hardware group.
Please confirm the following:
• Whether Opening 2A229B is intended to be provided with an automatic operator
• If an automatic operator is required, please provide the correct hardware requirements and the revised hardware group applicable to this opening
Clarification is requested to ensure proper coordination and compliance with the contract documents.
PROJECT MANAGER’S RESPONSE
TRACKING NO.: AMENDMENT NO.:
VA PROJECT ENGINEER/MANAGER: DATE:
Door 2A229B will require a hand wave auto operator Revised Hardware 7B-1 shall include:
1 Continuous Hinge HG315 AS 1 Push Plate 73C 1 Pull Plate 110x70B 1 Armor Plate K1050 35" high SA CSK 1 Wall Stop 401 2 Edge Guard 310B 1 Door Operator & Actuators by Section 08 71 13
AESUS Response 01/08/2026 mailto:charee.harris@va.gov