1 11 1 1 1 1
1S 1S1S 1S 1S 1S 1S
2 22 2 2 2 2
FIRE PROTECTION SYMBOL LIST
SYMBOL: DESCRIPTION:
FIRE PROTECTIONFP
FIRE PROTECTION - DRY SYSTEMFPD
SERVICE WATER - POTABLEW
AIR PRESSURE MAINTENANCE DEVICE
AIR SUPERVISORY SWITCH
ANGLE VALVE
BUTTERFLY VALVE WITH MONITOR SWITCH
OS&Y GATE VALVE
OS&Y GATE VALVE WITH MONITOR SWITCH
PRESSURE SWITCH
P
NO HATCH
LIGHT HAZARD COVERAGE AREA: 0.10 GPM/sq.ft. OVER A
REMOTE OPERATING AREA OF 1500 SQUARE FEET COMBINED
HOSE ALLOWANCE OF 100 GPM.
ORDINARY HAZARD GROUP l COVERAGE AREA: 0.15 GPM/sq.ft
OVER A REMOTE OPERATING AREA OF 1500 SQUARE FEET
AND COMBINED HOSE ALLOWANCE OF 250 GPM.
ORDINARY HAZARD GROUP ll COVERAGE AREA: 0.20 GPM/sq.ft
OVER A REMOTE OPERATING AREA OF 1500 SQUARE FEET AND
COMBINED HOSE ALLOWANCE OF 250 GPM.
SPRINKLER - WALL MOUNTED - EXISTING
SPRINKLER - EXISTING
SPRINKLER - CONCEALED - EXISTING
SPRINKLER - EXISTING
SPRINKLER - EXISTING
SPRINKLER - EXISTING
SPRINKLER - EXISTING
A
SPRINKLER - EXISTING
A
INSPECTOR TEST AND DRAIN VALVE
MONITOR SWITCH
COMPRESSED AIR - FIRE PROTECTIONCAF
PIPE CAP
PIPE DOWN
NEW CONNECTION
PIPE UP OR UP/DOWN
SHUTOFF VALVE NORMALLY OPEN
DRAINDFP
NOT ALL SYMBOLS MAY APPLY.
AUTOMATIC DRAIN VALVE
UNION/FLANGE
DIRECTION OF FLOW IN PIPE
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
CHECK VALVE
FLOW SWITCH
F
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
FIRE PROTECTION ABBREVIATION KEY
AD ACCESS DOOR
BFP BACKFLOW PREVENTER
N.C. NORMALLY CLOSED
ABOVE FINISHED FLOORAFF
NC NEW CONNECTION
NOT IN CONTRACTNIC
NORMALLY OPENN.O.
ABBR: DESCRIPTION:
TYPICALTYP
UNLESS NOTED OTHERWISEUNO
I.E. INVERT ELEVATION
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
LINE TYPE KEY:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
CEILINGS, AND FLOORS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, ACCESSORIES, ETC. COORDINATE PANEL TYPE AND COLOR
WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.
10. SEAL ALL WALL AND FLOOR PENETRATIONS AIRTIGHT WHERE PIPING PENETRATE.
PENETRATIONS THROUGH EXTERIOR WALLS SHALL BE SEALED AIRTIGHT WITH
WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, AND
FLOOR ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE
ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES SHALL BE SEALED WITH COMPONENTS
RATED FOR SUCH USE.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY BETWEEN DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
13. DO NOT EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
15. DO NOT SUPPORT EQUIPMENT, OR PIPING FROM METAL DECKING OR OTHER NON-
STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
16. COORDINATE EQUIPMENT TAGS WITH OWNER FOR TYPE AND NAMING PRIOR TO
SUBMITTING SHOP DRAWINGS AND ORDERING FINAL LABELS.
1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR
FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.
2. FIRE PROTECTION PIPE ROUTING IS SHOWN FOR GENERAL LAYOUT. DETERMINE EXACT
NUMBER OF SPRINKLERS, PIPE SIZING, AND PIPE ROUTING.
3. CENTER SPRINKLERS IN CEILING TILES IN BOTH DIRECTIONS IN ALL AREAS. IN AREAS WITH
2’X4’ CEILING TILES CENTERING USING A 2’X2’ CEILING PATTERN IS ACCEPTABLE.
4. NEW SPRINKLERS SHALL BE QUICK RESPONSE TYPE, UNLESS OTHERWISE NOTED.
CONTRACTOR SHALL NOT MIX STANDARD RESPONSE SPRINKLERS WITH QUICK RESPONSE
SPRINKLERS IN UNPARTITIONED SPACES.
5. PROVIDE COVERAGE ABOVE AND BELOW ALL DUCTWORK GREATER THAN 48" WIDE.
FIRE PROTECTION GENERAL NOTES:
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR
SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL
MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS WHETHER SHOWN OR NOT.
RATINGS WERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 11/02/2017.
FIRE / SMOKE BARRIER DESIGNATIONS
1-HOUR SMOKE BARRIER WALL
NON-RATED SMOKE PARTITION (CORRIDORS)
1-HOUR FIRE REATED BARRIER
2-HOUR FIRE RATED BARRIER
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :1
P
M
FP-001
FIRE PROTECTION COVER SHEET
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
31 79
BUILDING 1
GORPAT/
MATKAH
NOTES:
1. SEE FLOOR PLANS FOR ZONING REQUIREMENTS.
2. SPRINKLER SHALL HAVE COLOR CODED BULB THERMAL ELEMENT.
3. ALL SPRINKLERS SHALL BE UL AND FM LISTED.
4. CONTRACTOR TO VERIFY SPRINKLER REQUIREMENTS BASED ON ACTUAL INSTALLATION, USAGE, ARCHITECTURAL CEILING
PLAN AND NFPA 13 REQUIREMENTS.
5. TAG NAME IS PRIMARILY FOR IDENTIFIYING SPRINKLERS IN SUBMITTALS. IT MAY OR MAY NOT BE FOUND ELSEWHERE ON
THE DRAWINGS. CONTRACTOR TO SUBMIT ALL SPRINKLER TYPES TO BE USED.
6. AREAS ARE GENERAL IN NATURE. CONTRACTOR TO MATCH UNSCHEDULED AREAS TO SIMILAR SPACES.
7. SPRINKLERS SPECIFIED WITHIN FIRE SPRINKLER USAGE SCHEDULE ARE STANDARD COVERAGE TYPE. EXTENDED COVERAGE
SPRINKLERS ARE PERMITTED PROVIDED SPRINKLERS MEET THE REQUIREMENTS OF UL AND FM.
FIRE SPRINKLER USAGE SCHEDULE
AREA TYPE
(NOTE 1 & 6)
AREA
HAZARD
SPRINKLER
TEMPERATURE
RATING
MANUFACTURER &
MODEL NOTES
TAG NAME
(NOTE 4 & 5)
SPRINKLER
TYPE
RESPONSE
CATEGORY FINISH
2ND FLOOR WITH
CEILINGS, A611,
A613, A613B
SEE PLANS SPR-1 RECESSED
PENDENT
QUICK CHROME 155 VIKING VK, RELIABLE
F1FR, TYCO TY-FRB,
VICTAULIC V2708
NOTE 2, 3, 7
6TH FLOOR WITH
CEILINGS
SEE PLANS SPR-2 CONCEALED
WITH GASKET
STANDARD WHITE 155 VIKING B-2, RELIABLE
G4A, TYCO RF II,
VICTAULIC V3802
NOTES 2, 3, 7
A. DEDUCT ALT #1: ALL WORK IN BASE BID WITH THE FOLLOWING EXCEPTIONS / DEDUCTIONS:
1. WORK JOHN COCHRAN BUILDING 7 DELETE
BID ALTERNATE
CORRIDOR
H202
FILM VIEW
A216
RADIOGRAPHIC
AND
FLUOROSCOPIC
A217
TOILET
A218
RADIOGRAPHIC
A219
X-RAY
A220
CONTROL
A221
RADIOGRAPHIC
AND
FLUOROSCOPIC
A215
TOILET
A216C
CONTROL
A217AEQUIPMENT
STORAGE
A218C
TOILET
A219E
CONTROL
A219D
LASER PRINT
A219B
FILM STORAGE
A219C
DUMB WAITER
LOBBY
A219A
ELEC. CLOSET
A220A
CONTROL
A215A
CHASE
CH-A-7
7 6 5 3489
D D
A
B
C
SPR-E
SPR-E
FP
F P
FP
REVISE SPRINKLER PIPING AND
PROVIDE NEW HEADS AS
NECESSARY FOR FLOOR PLAN
WORK, ROOM DESIGNATION
CHANGES AND CEILING
HEIGHT/LAYOUT ADJUSTMENTS.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :0
P
M
1-2-FD-101A
SECOND FLOOR - FIRE PROTECTION DEMOLITION PLAN
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
32 79
BUILDING 1
GORPAT/
MATKAH
N O R
HT
1/4" = 1'-0"1
SECOND FLOOR - FIRE PROTECTION DEMOLITION PLAN
OFFICE
A602
HAC
A603
NURSE
MANAGER
A604
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE
RM.
A609 PROCEDURE
RM.
A610
SCOPE
A610A
PROCEDURE
RM.
A611
PROCEDURE
RM.
A612
SCOPE
CLEANING
A613B
CLEAN
A614
SOILED
A615
ANTE RM.
A613A
CLEAN UTILITY
A611A
SCOPE
CLEANING
DIRTY SIDE
A613
CORRIDOR
H601
NURSE BREAK
RM.
A616
WORKSTATION
A624
STAIRWELL NO.
S602
TOILET
A626A
OFFICE
A629
TOILET
A627A
TOILET
A628
OFFICE
A631
OFFICE
A632
BED RM.
A626
STAIRWELL NO.
S601
ELEC. CLOSET
A629A
CHASE
CH-A-6
CHASE
CH-A-7
CHASE
CH-A-8
CHASE
CH-A-9
CHASE
CH-A-10
CHASE
CH-A-12
CHASE
CH-A-11
CHASE
CH-A-16
CHASE
CH-A-17
CHASE
CH-A-18
F.E. CLOSET
H602A
7 6 5 2 13
48910
I
H H
G
F
E
REVISE SPRINKLER PIPING AND PROVIDE NEW
HEADS AS NECESSARY FOR NEW DUCTWORK
INSTALLATION AND CEILING ADJUSTMENTS.
COORDINATE LAYOUT WITH MECHANICAL
CONTRACTOR, ELECTRICAL CONTRACTOR, AND
ARCHITECTURAL.
FP
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E SPR-E SPR-E
SPR-E
SPR-E
SPR-E
SPR-E
SPR-E SPR-E
SPR-E
SPR-ESPR-E
SPR-E
SPR-E
SPR-E SPR-E
EXISTING DRAIN RISER
REMOVE EXISTING DRAIN
VALVE AND STORE FOR
REUSE AND ASSOCIATED
PIPING, HANGERS,
ACCESSORIES, ETC. CAP
CONNECTION AT DRAIN.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :0
P
M
1-6-FD-101A
SIXTH FLOOR PLAN - FIRE PROTECTION DEMOLITION PLAN
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
33 79
BUILDING 1
GORPAT/
MATKAH
N
O R HT
SIXTH FLOOR - FIRE PROTECTION DEMOLITION PLAN
FILM VIEW
A216
RADIOGRAPHIC
AND
FLUOROSCOPIC
A217
TOILET
A218
RADIOGRAPHIC
A219
X-RAY
A220
CONTROL
A221
RADIOGRAPHIC
AND
FLUOROSCOPIC
A215
TOILET
A216C
CONTROL
A217AEQUIPMENT
STORAGE
A218C
TOILET
A219E
CONTROL
A219D
LASER PRINT
A219B
FILM STORAGE
A219C
DUMB WAITER
LOBBY
A219A
ELEC. CLOSET
A220A
CONTROL
A215A
CHASE
CH-A-7
7 6 5 3489
D D
A
B
C
REVISE SPRINKLER PIPING AND
PROVIDE NEW HEADS AS
NECESSARY FOR FLOOR PLAN
WORK, ROOM DESIGNATION
CHANGES AND CEILING
HEIGHT/LAYOUT ADJUSTMENTS.SPR-E
SPR-E
FP
F P
FP
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :0
P
M
1-2-FP-101A
SECOND FLOOR - FIRE PROTECTION RENOVATION PLAN
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
34 79
BUILDING 1
GORPAT/
MATKAH
N
O R HT
SECOND FLOOR - FIRE PROTECTION RENOVATION PLAN
F
G
F
E
H H
I
OFFICE
A602
HAC
A603
NURSE
MANAGER
A604
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE
RM.
A609 PROCEDURE
RM.
A610
SCOPE
A610A
PROCEDURE
RM.
A611
PROCEDURE
RM.
A612
SCOPE
CLEANING
A613B
CLEAN
A614
SOILED
A615
ANTE RM.
A613A
CLEAN UTILITY
A611A
SCOPE
CLEANING
DIRTY SIDE
A613
CORRIDOR
H601
NURSE BREAK
RM.
A616
WORKSTATION
A624
STAIRWELL NO.
S602
TOILET
A626A
OFFICE
A629
TOILET
A627A
TOILET
A628
OFFICE
A631
OFFICE
A632
BED RM.
A626
STAIRWELL NO.
S601
ELEC. CLOSET
A629A
CHASE
CH-A-6
CHASE
CH-A-7
CHASE
CH-A-8
CHASE
CH-A-9
CHASE
CH-A-10
CHASE
CH-A-12
CHASE
CH-A-11
CHASE
CH-A-16
CHASE
CH-A-17
CHASE
CH-A-18
F.E. CLOSET
H602A
REVISE SPRINKLER PIPING AND PROVIDE NEW
HEADS AS NECESSARY FOR NEW DUCTWORK
INSTALLATION AND CEILING ADJUSTMENTS.
COORDINATE LAYOUT WITH MECHANICAL
CONTRACTOR, ELECTRICAL CONTRACTOR, AND
ARCHITECTURAL.
SCOPE
FP FPFP
SPR-E SPR-E
SPR-E
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :1
P
M
1-6-FP-101A
SIXTH FLOOR PLAN - FIRE PROTECTION RENOVATION PLAN
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
35 79
BUILDING 1
GORPAT/
MATKAH
N O R
HT
SIXTH FLOOR - FIRE PROTECTION RENOVATION PLAN
1 11 1 1 1 1
1S 1S1S 1S 1S 1S 1S
2 22 2 2 2 2
PLUMBING SYMBOL LIST
SYMBOL: DESCRIPTION:
PIPE SERVING FIXTURE ON FLOOR ABOVE
(EXAMPLE: FD = FLOOR DRAIN)FD
PITCH PIPE IN DIRECTION
RD-1
6"(1000)
ROOF DRAIN PROPERTIES SYMBOL
SIZE (ROOF SQ. FT.)
DIELECTRIC CONNECTION
UNION/FLANGE
BALANCING VALVE (NUMBER INDICATES GPM)
GPM
CHECK VALVE
REDUCER - REFERENCE SPECIFICATION
FOR CONCENTRIC/ECCENTRIC AND FOT/FOB
METERM
ALIGNMENT GUIDE
PIPE ANCHOR
EXPANSION JOINT
PIPE CAP
PIPE DOWN
PIPE UP OR UP/DOWN
DIRECTION OF FLOW IN PIPE
NEW CONNECTION
SHUTOFF VALVE NORMALLY OPEN
SHUTOFF VALVE NORMALLY CLOSED
COLD WATER - POTABLECW
DT DRAIN TILE
HOT WATER - POTABLEHW
HOT WATER CIRCULATING - POTABLEHWC
HOT WATER - POTABLE NUMBER INDICATES TEMPHW140
HOT WATER CIRC. - POTABLE NUMBER INDICATES TEMPHWC140
NON-POTABLE COLD WATERNCW
NON-POTABLE HOT WATERNHW
SANITARY DRAINAGESAN
STORM DRAINAGE (ROOF SQUARE FOOTAGE)ST(1,000)
STS STORM DRAINAGE (SECONDARY)
VENTV
DRAIND
G NATURAL GAS
NOT ALL SYMBOLS MAY APPLY.
PRESSURE REDUCING VALVE (LIQUID/GAS)
SOLENOID VALVE
SAFETY/RELIEF VALVE
VACUUM BREAKER
PRESSURE GAUGE (FURNISHED WITH BALL VALVE)P
TEMPERATURE SENSOR WITH WELL
T
THERMOMETER WITH WELL (DIAL TYPE)T
THERMOMETER WITH WELL (FILLED TYPE)
PUMP
GRV GAS REGULATOR VENT
SERVICE WATER - POTABLEW
PIPE CONTINUATION
PRESSURE SENSOR (FURNISHED WITH BALL VALVE)P
COLD WATER CIRCULATING - POTABLECWC
PLUMBING ABBREVIATION KEY
CO CLEANOUT
CLINICAL SINKCS
FLOOR CLEANOUTFCO
FLOOR DRAINFD
FLOOR SINKFS
GARBAGE DISPOSERGD
HOSE BIBBHB
I.E. INVERT ELEVATION (FOR REFERENCE ONLY)
LAVATORYLAV
MOP BASINMB
MIXING VALVEMV
ROOF DRAINRD
SHOWERSH
SINKSK
SERVICE SINKSS
TRENCH DRAINTD
TRAP PRIMERTP
WATER CLOSETWC
WALL CLEANOUTWCO
WATER HEATERWH
WASHING MACHINE FIXTUREWMF
YARD CLEANOUTYCO
ELECTRIC WATER COOLEREWC
VENT THROUGH ROOFVTR
AD ACCESS DOOR
ABOVE FINISHED FLOORAFF
BFP BACKFLOW PREVENTER
NC NEW CONNECTION
NOT IN CONTRACTNIC
ABBR: DESCRIPTION:
TYPICALTYP
UNLESS NOTED OTHERWISEUNO
EXISTINGE
FLOW METERFM
WATER METERWM
CAST IRONCI
DUCTILE IRONDI
UTILITY BOXUB
OVERFLOW DRAINOFD
VALVE IN VERTICALVIV
PLAN OR DETAIL NUMBER
PLAN OR DETAIL NAME
PLAN OR DETAIL SCALE
DETAIL REFERRED TO BY SECTION CUT
SHEET DETAIL IS LOCATED ON
NAME
VIEW NAME
1/8" = 1'-0"
M101
T101
SIM
DETAIL REFERRED TO BY ELEVATION
SHEET DETAIL IS LOCATED ON
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
SIM
INDICATES SIMILAR DETAIL
REFERENCED IN MULTIPLE LOCATIONS
LEVEL NAME
10' - 0" HEIGHT ABOVE
PROJECT 0' - 0"
1 INDICATES NOTE USED TO DESCRIBE
ADDITIONAL INFORMATION ABOUT
WORK REQUIRED, SPECIFIC TO THE
SHEET AND/OR DETAIL
N
O R HT
INDICATES DIRECTION OF TRUE NORTH
VIEW KEY
NEW WORK BY THIS CONTRACTOR
(DARK SOLID LINE)
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR
(DARK LONG DASHED LINE)
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN
(LIGHT SOLID LINE)
LINE TYPE KEY:
MECHANICAL GENERAL NOTES:
THESE NOTES APPLY TO ALL MECHANICAL SHEETS AND TRADES, INCLUDING BUT NOT LIMITED
TO, FIRE PROTECTION, PLUMBING, MEDICAL GAS, VENTILATION, PIPING AND TEMPERATURE
CONTROL.
1. DRAWINGS SHOWING LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, ETC. ARE
DIAGRAMMATIC AND MAY NOT ALWAYS REFLECT EXACT INSTALLATION CONDITIONS.
DRAWINGS SHOW THE GENERAL ARRANGEMENT OF DUCTWORK, PIPING, EQUIPMENT, ETC.,
AND MAY NOT INCLUDE ALL OFFSETS AND FITTINGS REQUIRED FOR COMPLETE
INSTALLATION. THE DRAWINGS SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING
CONSTRUCTION AND THE WORK OF OTHERS WILL PERMIT.
2. DO NOT SCALE DRAWINGS. VERIFY ALL DIMENSIONS AND CLEARANCES FROM
ARCHITECTURAL, STRUCTURAL, SUBMITTALS, AND OTHER APPROPRIATE DRAWINGS OR
PHYSICALLY AT SITE. REVIEW ALL DRAWINGS, INCLUDING THOSE OF OTHER TRADES.
3. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO PROVIDE
CLEARANCES REQUIRED FOR OPERATION, MAINTENANCE, CODE COMPLIANCE, AND TO
VERIFY NON-INTERFERENCE WITH OTHER WORK. DO NOT FABRICATE PRIOR TO
VERIFICATION OF NECESSARY CLEARANCES FOR ALL TRADES. BRING ANY INTERFERENCES
OR CONFLICTS TO THE ATTENTION OF THE ARCHITECT/ENGINEER BEFORE PROCEEDING
WITH FABRICATION OR EQUIPMENT ORDERS.
4. REVIEW SPACE REQUIREMENTS OF EQUIPMENT SPECIFIED OR SUBSTITUTED AND MAKE
REASONABLE ACCOMMODATIONS IN LAYOUT AND POSITIONING TO PROVIDE PROPER
ACCESS.
5. ANY CHANGES REQUIRED TO ELIMINATE CONFLICTS OR THAT RESULT FROM A FAILURE TO
COORDINATE SHALL BE MADE BY THE CONTRACTOR WITHOUT ADDITIONAL COST OR
EXPENSE TO OTHERS.
6. EACH CONTRACTOR IS RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH ELECTRICAL
CHANGES REQUIRED FOR EQUIPMENT PROPOSED THAT DIFFERS FROM THE BASIS OF
DESIGN.
7. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN, ELECTRICAL, TECHNOLOGY
AUDIO/VISUAL, AND OTHER MECHANICAL PLANS FOR EXACT LOCATIONS OF ALL CEILING
MOUNTED DEVICES, OTHER THAN SPRINKLERS.
8. EACH CONTRACTOR IS RESPONSIBLE FOR DAMAGE CAUSED BY THEIR ACTIONS TO WALLS,
CEILINGS, AND FLOORS. THE CONTRACTOR WHOSE WORK CAUSES DAMAGE IS
RESPONSIBLE FOR PATCHING TO MATCH ORIGINAL CONSTRUCTION, FIRE RATING, AND
FINISH.
9. IN AREAS WITH DRYWALL CEILINGS COORDINATE LOCATIONS OF ACCESS PANELS WITH THE
GC FOR ACCESS TO VALVES, ACCESSORIES, ETC. COORDINATE PANEL TYPE AND COLOR
WITH ARCHITECT. NOTIFY THE GC OF THE REQUIRED ACCESS PANELS PRIOR TO BIDDING.
10. SEAL ALL WALL AND FLOOR PENETRATIONS AIRTIGHT WHERE PIPING PENETRATE.
PENETRATIONS THROUGH EXTERIOR WALLS SHALL BE SEALED AIRTIGHT WITH
WATERPROOFING MATERIALS RECOMMENDED BY MANUFACTURER FOR OUTDOOR USE.
11. CAULK ALL PIPE PENETRATIONS OF FULL HEIGHT NON-FIRE RATED WALL, PARTITION, AND
FLOOR ASSEMBLIES. THIS IS ESSENTIAL TO PREVENT NOISE TRANSMISSION FROM ONE
ROOM TO ANOTHER AND TO PROVIDE THE DESIRED NC LEVELS WITHIN ROOMS.
PENETRATIONS THROUGH FIRE -RATED ASSEMBLIES SHALL BE SEALED WITH COMPONENTS
RATED FOR SUCH USE.
12. EQUIPMENT SIZES AND SERVICE CLEARANCE REQUIREMENTS VARY BETWEEN DIFFERENT
MANUFACTURERS. CONSULT APPROVED SHOP DRAWINGS FOR EQUIPMENT SIZES AND
REQUIRED SERVICE CLEARANCES. COORDINATE WITH LAYOUT OF EQUIPMENT PADS,
PIPING, DUCTWORK, ETC.
13. DO NOT EQUIPMENT SERVICE CLEARANCES.
14. MAINTAIN MINIMUM 3'-6” CLEARANCE IN FRONT OF ALL ELECTRICAL PANELS, MOTOR
STARTERS, SWITCHES, AND DISCONNECTS.
15. DO NOT SUPPORT EQUIPMENT, OR PIPING FROM METAL DECKING OR OTHER NON-
STRUCTURAL BUILDING ELEMENTS. ANCHORS EMBEDDED IN CONCRETE SHALL BE
CRACKED CONCRETE APPROVED IN ACCORDANCE WITH SPECIFICATIONS.
16. COORDINATE EQUIPMENT TAGS WITH OWNER FOR TYPE AND NAMING PRIOR TO
SUBMITTING SHOP DRAWINGS AND ORDERING FINAL LABELS.
1. THE SYMBOLS AND THE MATERIAL LIST ARE FOR THE CONVENIENCE OF THE CONTRACTOR.
CONTRACTOR SHALL VERIFY QUANTITIES AND FURNISH ALL MATERIALS REQUIRED FOR
FULLY OPERATIONAL SYSTEMS, WHETHER SPECIFIED OR NOT.
2. CONTRACTOR SHALL VERIFY THAT FIXTURES SUPPLIED ARE APPROVED PER ALL
APPLICABLE STATE, LOCAL AND GOVERNING AUTHORITIES.
3. ALL FIXTURES SHALL CONFORM TO FEDERAL ACT S.3874
4. VERIFY PIPE SIZES, INVERT ELEVATIONS, AND LOCATIONS PRIOR TO BEGINNING ANY WORK.
5. REFER TO THE PLUMBING ROUGH-IN SCHEDULE FOR THE SIZES OF BRANCH PIPES TO
PLUMBING FIXTURES.
6. FOR CLARITY, NOT ALL VALVES HAVE BEEN SHOWN. PROVIDE SHUTOFF VALVES IN
DOMESTIC WATER PIPING SERVING EACH ROOM WITH FIXTURES. ANGLE STOPS SHALL NOT
BE CONSIDERED SHUTOFF VALVES.
PLUMBING GENERAL NOTES:
THE LINE TYPES SHOWN ARE FOR THE CONVENIENCE OF THE CONTRACTOR. THE CONTRACTOR
SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL
MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS WHETHER SHOWN OR NOT.
RATINGS WERE ACQUIRED FROM THE ARCHITECTURAL PLANS DATED 11/02/2017.
FIRE / SMOKE BARRIER DESIGNATIONS
1-HOUR SMOKE BARRIER WALL
NON-RATED SMOKE PARTITION (CORRIDORS)
1-HOUR FIRE REATED BARRIER
2-HOUR FIRE RATED BARRIER
TEMPERATURE CONTROLS CONTRACTORT.C.C.
SECURITY CONTRACTORS.C.
AUDIO/VISUAL CONTRACTORA.V.C.
NURSE CALL CONTRACTORN.C.C.
CIVIL CONTRACTORC.C.
FIRE PROTECTION CONTRACTORF.P.C.
PLUMBING CONTRACTORP.C.
GENERAL CONTRACTORG.C.
MECHANICAL CONTRACTORM.C.
ELECTRICAL CONTRACTORE.C.
CONTRACTOR ABBREVIATION KEY
ABBR: DESCRIPTION:
TECHNOLOGY CONTRACTORT.C.
CONSTRUCTION MANAGERC.M.
FAUCET SEE
SPECIFICATIONS
LAMINAR FLOW
CONTROL DEVICE
OFFSET
WASTE
TRAP
PARALLEL
TO WALL
LOOSE
KEY STOP
ESCUTCHEON
FINISHED
FLOOR
[8 m m
[102mm]
[2 m m
F O
R F
IX
T
U R
E H
E
IG
H T
S S
E E
A R
C H
IT
E
C T
U R
A L D
R A
W
IN
G S
4"
/4
0' 2"0' 2"
MINIMUM 16 GAGE GALVANIZED
STEEL PLATE 12"x48" [300x1200mm] MIN. SECURED TO
A MIN. 4 STUDS PER LAVATORY
1/4" [6mm]∅ MOLLY BOLT HOLLOW
WALL ANCHOR (1 EA. SIDE OF LAV)
MIN. (3) 1/4"
[6mm] MACHINE
BOLTS W/DOUBLE
LOCK NUTS ON
BACK SIDE
MIN. 5 1/4"
[131mm]∅ GALV.
MACHINE BOLTS
WELDED TO PLATE
1/4" [6mm]
TYP. 1/8"
TYP. [3mm]
A A
PLAN
SECTION-A
NOTES:
1. AT LAVS WITH FOOT PEDAL CONTROLS
PROVIDE AN ADDITIONAL 16 GAGE
GALVANIZED STEEL PLATE 12"x16" [300x600mm] SECURED TO A MINIMUM
OF 2 STUDS PER FOOT PEDAL.
2. PROVIDE 20 GAGE STUDS WHEN HEIGHT
EXCEEDS 12'-0" [3600mm]
STEEL HANGER BY LAV
MFGR
STEEL WALL
PLATE
WALL
ANCHOR
STUDS
FOR FIXTURE
HEIGHT SEE
ARCHITECTURAL
DRAWINGS
V A
R
IE
S
[9 m m
T O
F L O
O R th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :1
P
M
P-001
PLUMBING COVER SHEET
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
36 79
BUILDING 1
GORPAT/
MATKAH
11 & 7
BLDG 7 - NOT FULLY SPRINKLERED
BLDG 1 - FULLY SPRINKLERED
A. DEDUCT ALT #1: ALL WORK IN BASE BID WITH THE FOLLOWING EXCEPTIONS / DEDUCTIONS:
1. WORK JOHN COCHRAN BUILDING 7 DELETE
BID ALTERNATE
P-408 LAVATORY 2 [ 50 ] 1.5 [ 38 ] .5 [ 13 ] .5 [ 13 ] 2 2 YES NO
P-202
URINAL WALL
HUNG
2 [ 50 ] 1.5 [ 38 ] .75 [ 19 ] 2 5 N/A NO
P-103
WATER CLOSET,
WALL HUNG
3 [ 75 ] 2 [ 50 ] 1.25 [ 31 ] 6 10 N/A NO
IN [mm] IN [mm] IN [mm] IN [mm]
MARK DESCRIPTION
WASTE PIPE VENT PIPE COLD WATER HOT WATER WASTE
FIXTURE
UNITS
WATER
FIXTURE
UNITS
WRIST
BLADE
HANDLES
ELECTRIC
SENSOR
REMARKS
PLUMBING FIXTURE SCHEDULE
NO SCALE1
TYPICAL WHEELCHAIR LAVATORY DETAIL
NO SCALE2
LAVATORY MOUNTING DETAIL
FILM VIEW
A216
RADIOGRAPHIC
AND
FLUOROSCOPIC
A217
TOILET
A218
RADIOGRAPHIC
A219
X-RAY
A220
CONTROL
A221
RADIOGRAPHIC
AND
FLUOROSCOPIC
A215
TOILET
A216C
CONTROL
A217AEQUIPMENT
STORAGE
A218C
TOILET
A219E
CONTROL
A219D
LASER PRINT
A219B
FILM STORAGE
A219C
DUMB WAITER
LOBBY
A219A
ELEC. CLOSET
A220A
CONTROL
A215A
CHASE
CH-A-7
7 6 5 3489
D D
A
B
C
REMOVE SINK AND ALL BRACKETS, HANGERS,
ACCESSORIES. REMOVE DOMESTIC PIPING
BACK TO MAIN IN CEILING OF FLOOR BELOW.
REMOVE SANITARY PIPING BACK INTO WALL
AND CAP.
2" SAN DN,
2" V TO STACK
4" SAN DN,
2 1/2" V UP
EXISTING OXYGEN AND VACUUM LINES TO
REMAIN. LINES ARE STACKED VERTICALLY
WITH ONE ABOVE THE OTHER.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :5
P
M
1-2-PD-101A
SECOND FLOOR - PLUMBING DEMOLITION PLAN
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
37 79
BUILDING 1
GORPAT/
MATKAH
N
O R HT
SECOND FLOOR - PLUMBING DEMOLITION PLAN
NURSE
MANAGER
A604
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE
RM.
A609 PROCEDURE
RM.
A610
SCOPE
A610A
PROCEDURE
RM.
A611
PROCEDURE
RM.
A612
SCOPE
CLEANING
A613B
CLEAN
A614
SOILED
A615
ANTE RM.
A613A
CLEAN UTILITY
A611A
SCOPE
CLEANING
DIRTY SIDE
A613
CORRIDOR
H601
NURSE BREAK
RM.
A616
WORKSTATION
A624
STAIRWELL NO.
S602
TOILET
A626A
OFFICE
A629
TOILET
A627A
TOILET
A628
BED RM.
A626
STAIRWELL NO.
S601
ELEC. CLOSET
A629A
CHASE
CH-A-6
CHASE
CH-A-7
CHASE
CH-A-8
CHASE
CH-A-9
CHASE
CH-A-10
CHASE
CH-A-12
CHASE
CH-A-11
CHASE
CH-A-17
CHASE
CH-A-18
F.E. CLOSET
H602A
7 6 5 2 13
48910
I
H H
G
F
E
WC-E
SK-E
SK-E
WC-E
LAV-E
SK-E
WC-E
MB-E
WC-E
SK-E
2"HW
3"CW
2 1/2" CW DN
1 1/4" HW DN
2 1/2" CW
1 1/4" CW
3/4"O
1/2"MA
1"MV
MGO-E
1/2"O
1/2"MA
3/4"MV
MGO-E
MGO-E
MGO-E
MGO-E
2 1/2"CW
1/2"O
1/2"MA
3/4"MV
1/2"O
1/2"MA
3/4"MV
MGO-E
MGO-E
SK-E
SK-E
SK-E
SK-E
MB-E
FD-E
SK-E
SK-E
SK-E
SK
4" SAN DN
WC
WC-E
SK FD
FD-E
4" SAN UP & DN
4" SAN UP & DN
4" SAN
UP & DN
FD-E FD-E
SK-E
SK-E
3/4"HW
1 1/2"CW 3/4"HW
1 1/2"CW
1 1/2"CW
3/4"HW
3/4"HW
1 1/2"CW
3" CW DN
2" HW DN
2 1/2" V UP & DN
4" V UP & DN
4" V UP & DN
2"V
"V
3" ST UP & DN
3" ST UP & DN
4" ST UP & DN
2" CW UP
2" CW UP
SK
SK
SH
SK-E
FD-E
WC-E
4"SAN
WC-E
4"SAN
3"SAN
P505
P403
P403
"V
2"V 2"V
P403
P414 P104
P403
P403
P104
P701
2"V
"V
4"SAN
4"SAN
4"SA
N
2"SAN
2"SAN
2"SAN
2"SAN
2"SAN
"S
A N
"S
A N
4"SAN
4"SAN
P403
P104
P414
2"HW
3"CW
2"HW
3"CW
P403
P414
P104
P403
2"V
"V
2"V
"V
2"SAN
3"SAN
2"SAN
4"SAN
3/4"HW
1 1/2"CW
REMOVE PIPING AS INDICATED FOR INSTALLATION
OF NEW DUCT WORK. PREPARE PIPING FOR NEW
CONNECTION. COORDINATE PIPING REMOVAL,
RELOCATION, ELEVATION AND INSTALLATION WITH
MECHANICAL CONTRACTOR. (TYPICAL ALL)
2" V DN
4" SAN UP
3" SAN UP
4"SA
N
4" SAN DN
2" V UP
REMOVE PIPING AS SHOWN
INCLUDING ELBOW UP TO FLOOR
ABOVE AND PREPARE FOR NEW
CONNECTION (TYP.)
/2
"O
/2 "M
A
/4 "M
V
4"SAN
WORK REQUIRED ON 8TH
FLOOR FOR BACKFLOW
PREVENTOR INSTALLATION.
REFER TO SHEET 1-8-
MD-101A. COORDINATE
WORK WITH OWNER AND
MECHANICAL CONTRACTOR.
WORK REQUIRED ON 8TH
FLOOR FOR DUCT CHASE
INSTALLATION. REFER TO
SHEET 1-8-MD-101A.
COORDINATE WORK WITH
OWNER AND MECHANICAL
CONTRACTOR.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :0
P
M
1-6-PD-101A
SIXTH FLOOR PLAN - PLUMBING DEMOLITION
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
38 79
BUILDING 1
GORPAT/
MATKAH
N
O R HT
SIXTH FLOOR - PLUMBING DEMOLITION PLAN
PIPE BASEMENT
B2
SERVICE RM.
B1
B
C
D
E
F
G
A
2 1
1" CW UP
3/4"HW
3/4"CW
1"CW
1"HW
3/4" CW UP
1/2"HWC
1"HW
1 1/4"CW
1/2"HWC
3/4"HW
3/4"CW
HB-E
3/4"HWC
1"HW
1 1/4"CW
3/4"HW
3"CW
1 1/2"CW
1 1/4"HW
1 1/4"CW
2 1/2"CW
1 1/2"HW
1"HWC
3/4" MAKE UP WATER
EXPANSION TANK
2 1/2"CW
2"HW
1"HWC
3/4"HW
3/4"CW
2 1/2"CW
2"HW
1"HWC
WH-E
CS
2" SAN UP
2"V
2"V
1 1/2"V
4"SAN
2"SAN
UP TO L-3E
ABOVE.
UP TO P-92, P-66D,
P-104E ABOVE.
UP TO HI-60E
ABOVE.
UP TO (1) N-3E (1)
C.S. ABOVE
UP TO L-3E &
CS. ABOVE
UP TO VL-114
ABOVE
2"SAN
2"SAN
4"SAN
UP TO A-3E ABOVE
UP TO R-3E, N-3E
& COMPRESSOR
ABOVE
REMOVE PIPING
BACK TO MAIN
AND CAP
EXISTING 120
GALLON ELECTRIC
WATER HEATER
/2 "C
W
BFP-E
BFP-E
ET-E
4" ST UP
CO
2"ST
FD
ST UP TO ROOF
3" ST UP
8"ST 8"ST
"S
T
CO
3/4"CW
4"SAN
1 1/2"VAC
3/4"MA
1 1/4"G
3/4"VAC
1/2"MA
3/4"G
3/4"VAC
1/2"MA
3/4"G
1/2"G
1/2"MA
1/2"VAC
REMOVE PIPING
BACK TO VALVES
AND CAP.
5" ST
S T
S T
3/4" CW
3/4" HW
3/4"HWC
3/4"HW
1 1/2"CW
1 1/2"CW
3/4"HW
3/4"HWC
3/4"VAC
1/2"MA
3/4"G REMOVE EXISTING CAP
AND PREPARE FOR
NEW CONNECTION.
REMOVE PIPING AND
PREPARE FOR NEW
CONNECTION.
REMOVE PIPING IN VERTICAL
RISER AND PREPARE FOR NEW
CONNECTION.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:4 :5
P
M
7-B-PD-101
BASEMENT - PLUMBING DEMOLITION PLAN
ST. LOUIS MO - JOHN COCHRAN
SCOPRZ
39 79
BUILDING 7
GORPAT/
MATKAH
N
O R HT
1/8" = 1'-0"1
BASEMENT - PLUMBING DEMOLITION PLAN
DEDUCT ALTERNATE
B
C
D
E
F
G
A
2 1
REMOVE SINK AND ALL BRACKETS,
HANGERS, ACCESSORIES, ETC.
REMOVE DOMESTIC PIPING BACK
TO MAIN AND CAP. REMOVE
SANITARY AND VENT PIPING BACK
INTO WALL AND CAP.
REMOVE LAB GAS OUTLETS
AND ALL BRACKETS,
HANGERS, ACCESSORIES,
ETC. REMOVE PIPING BACK TO
MAIN IN CRAWL SPACE BELOW
AND CAP.
1 1/2" V DN
3" VTR
2 1/2"V
REMOVE PIPING FROM
COMPRESSORS ABOVE FREEZER
DOWN TO PIPE MAINS IN
CRAWLSPACE AND CAP.
FD-E
ST UP TO ROOF
"V
2"V
2"V th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:4 :5
P
M
7-1-PD-101
FIRST FLOOR - PLUMBING DEMOLITION PLAN
ST. LOUIS MO - JOHN COCHRAN
SCOPRZ
40 79
BUILDING 7
GORPAT/
MATKAH
N O R
HT
1/8" = 1'-0"1
FIRST FLOOR - PLUMBING DEMOLITION PLAN
F
G
F
E
H H
I
OFFICE
A602
HAC
A603
NURSE
MANAGER
A604
MED. PREP.
A605
NURSE STATION
A606
NOUR.
A607
GI PROCEDURE
ROOM
A608
PROCEDURE
RM.
A609 PROCEDURE
RM.
A610
SCOPE
A610A
PROCEDURE
RM.
A611
PROCEDURE
RM.
A612
SCOPE
CLEANING
A613B
CLEAN
A614
SOILED
A615
ANTE RM.
A613A
CLEAN UTILITY
A611A
SCOPE
CLEANING
DIRTY SIDE
A613
CORRIDOR
H601
NURSE BREAK
RM.
A616
WORKSTATION
A624
STAIRWELL NO.
S602
TOILET
A626A
OFFICE
A629
TOILET
A627A
TOILET
A628
OFFICE
A631
OFFICE
A632
BED RM.
A626
STAIRWELL NO.
S601
ELEC. CLOSET
A629A
CHASE
CH-A-6
CHASE
CH-A-7
CHASE
CH-A-8
CHASE
CH-A-9
CHASE
CH-A-10
CHASE
CH-A-12
CHASE
CH-A-11
CHASE
CH-A-16
CHASE
CH-A-17
CHASE
CH-A-18
F.E. CLOSET
H602A
WC-E
SK-E
SK-E
WC-E
LAV-E
SK-E
WC-E
MB-E
WC-E
SK-E
2"HW
3"CW
2 1/2" CW
1 1/4" CW
3/4"O
1/2"MA
1"MV
MGO-E
1/2"O
1/2"MA
3/4"MV
MGO-E
MGO-E
MGO-E
MGO-E
SK-E
SK-E
SK-E
SK-E
MB-E
FD-E
SK
SK
SK-E
SK
WC
WC-E
SK
FD-E
FD-E
4" SAN UP & DN
4" SAN UP & DN
4" SAN UP & DN
FD-E FD-E
SK-E
SK-E
3/4"HW
1 1/2"CW
3" CW DN
2" HW DN
2 1/2" V UP & DN
4" V UP
& DN
4" V UP & DN
2"V
"V
3" ST UP & DN
3" ST UP & DN
4" ST UP & DN
2" CW UP
2" CW UP
SK
SK
SH
SK
FD-E
WC-E
WC-E
P505
P403
P403
"V
2"V
P403
P414 P104
P403
P403
P104
P701
4"SAN
4"SAN
2"SAN
2"SAN
P403
P104
P414
2"HW
3"CW
2"HW
3"CW
P403 P414
P104
P403
2"V
"V
2"V
2"SAN
4"SAN
4"SAN
2"V
4"SAN
2"SAN
2"V
2"V
"V
"V
"S
A N
3"SAN
3"SAN
3/4"HW
1 1/2"CW
INSTALL PIPING AS INDICATED FOR INSTALLATION
OF NEW DUCT WORK. COORDINATE PIPING
RELOCATION, ELEVATION AND INSTALLATION WITH
MECHANICAL CONTRACTOR. (TYPICAL ALL)
MGO-E
3" SAN UP
4" SAN DN
2" V DN
4" SAN DN
2" V UP
2 1/2" CW DN
1 1/4" HW DN
/2
"O
/2 "M
A
/4
"M V
PROVIDE NEW TEE CONNECTION
INTO RISER FOR ELEVATION
CHANGE FOR VENT
PROVIDE NEW TEE CONNECTION
INTO RISER FOR ELEVATION
CHANGE FOR VENT
4" SAN UP
3"SAN
"S
A N
4"SAN
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC NC
NC
NC
NC
NC
NC
2"V
3/4"O
1/2"MA
1"MV
NC IN
VERTICAL
/4
"H W
/2 "C
W
PROVIDE NEW ELBOW INSTALLED AS TIGHT TO
STRUCTURE ABOVE AS POSSIBLE TO RAISE
ELEVATION OF PIPING FOR NEW DUCT
INSTALLATION. (TYP.)
NC IN
VERTICAL
"V
/2 "C
W
/4 "H
W
/4
"C W
/4
"H W
3/4"O
1/2"MA
3/4"MV
1/2"MA
1/2"O
1/2"O
1/2"MA
3/4"MV
2"V
2"V
WORK REQUIRED ON 8TH
FLOOR FOR BACKFLOW
PREVENTOR INSTALLATION.
REFER TO SHEET 1-8-
MD-101A. COORDINATE
WORK WITH OWNER AND
MECHANICAL CONTRACTOR.
WORK REQUIRED ON 8TH
FLOOR FOR DUCT CHASE
INSTALLATION. REFER TO
SHEET 1-8-MD-101A.
COORDINATE WORK WITH
OWNER AND MECHANICAL
CONTRACTOR.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
FULLY SPRINKLERED
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:3 :0
P
M
1-6-PL-101A
SIXTH FLOOR PLAN - PLUMBING RENOVATION
ST. LOUIS, MO - VA JOHN COCHRAN
SCOPRZ
41 79
BUILDING 1
GORPAT/
MATKAH
N
O R HT
SIXTH FLOOR - PLUMBING RENOVATION PLAN
PIPE BASEMENT
B2
SERVICE RM.
B1
B
C
D
E
F
G
A
2 1
1" CW UP
3/4"HW
3/4"CW
1"CW
1"HW
3/4" CW UP
1/2"HWC
1"HW
1 1/4"CW
1/2"HWC
3/4"HW
3/4"CW
HB-E
3/4"HWC
1"HW
1 1/4"CW
3/4"HW
3"CW
1 1/2"CW
1 1/4"HW
1 1/4"CW
2 1/2"CW
1 1/2"HW
1"HWC
3/4" MAKE UP WATER
EXPANSION TANK
2 1/2"CW
2"HW
1"HWC
3/4"HW
3/4"CW
2 1/2"CW
2"HW
1"HWC
WH-E
CS
2" SAN UP
2"V
2"V
1 1/2"V
4"SAN
2"SAN
UP TO L-3E
ABOVE.
UP TO P-92, P-66D,
P-104E ABOVE.
UP TO HI-60E
ABOVE.
UP TO (1) N-3E (1)
C.S. ABOVE
UP TO L-3E &
CS. ABOVE
UP TO VL-114
ABOVE
2"SAN
2"SAN
4"SAN
UP TO A-3E ABOVE
REMOVE PIPING
FROM SINK DOWN TO
MAIN AND CAP
EXISTING 120
GALLON ELECTRIC
WATER HEATER
BFP-E
BFP-E
ET-E
4" ST UP
CO
2"ST
FD
ST UP TO ROOF
3" ST UP
8"ST 8"ST
"S
T
CO
3/4"CW
1 1/2"VAC
3/4"MA
1 1/4"G
3/4"VAC
1/2"MA
3/4"G
3/4"VAC
1/2"MA
3/4"G
1/2"G
1/2"MA
1/2"VAC
1 1/2"CW
CAP
3"SAN
1 1/2" CW UP
3" SAN UP
2" V UP
FD
1 1/2" CW UP
3" SAN UP
3/4" HW UP
2" SAN UP
3/4" CW UP 2" SAN UP
3/4" CW UP FD
1 1/2" V UP
WHA-1
1 1/2" CW UP
3" SAN UP
FCO
3"SAN
0.5
2" SAN UP
WHA-1
5" ST
S T
5" ST
/2 "C
W
NC
3/4"HW
3/4"HWC
TP-1
TP-1
INSTALL SHUT OFF, BALANCE,
CHECK, AND SHUT OFF VALVE
ASSEMBLY IN BASEMENT
MECHANICAL ROOM. DEVICES
SHOWN IN CRAWLSPACE FOR
CLARITY OF DEVICES.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:4 :0
P
M
7-B-PL-101
BASEMENT - PLUMBING RENOVATION PLAN
ST. LOUIS MO - JOHN COCHRAN
SCOPRZ
42 79
BUILDING 7
GORPAT/
MATKAH
N
O R HT
1/8" = 1'-0"1
BASEMENT - PLUMBING RENOVATION PLAN
B
C
D
E
F
G
A
2 1
COORDINATE FLOOR
CLEANOUT LOCATION WITH
WATER CLOSET LOCATION.
2"V DN
2" SAN DN
2" SAN DN
2" V DN
2"V DN
2"V
FD-C
FD-C
TP-2
TP-2
P-408
P-103
P-103
P-408
P-202
P-103
CONNECT TO
EXISTING 3"
VTR VERTICAL
1 1/2" V DN
3" VTR
2"V
3/4" HW DN
1 1/2" CW DN
1 1/2" V DN
3/4" CW DN
3/4" CW DN
1 1/2" CW DN
1 1/2" V DN
1 1/2" CW DN
3/4"H W
2 1/2"V
"V
2"V
2"V
FD-E
ST UP TO ROOF
3/4" CW DN
2" SAN DN
3/4" HW DN
2"V
2"V
FD-CFCO-1
3"SAN
3"SAN
P-103
P-202
P-408
P-103
P-103
FD-C
5" ST
2"V
2"V
1 1/2"V
2"SAN
P-408
2"V 3"V 2"V 2 1/2"V
2"V
1 1/2"V
2"V 1 1/2"V 2"V
2"V
2"V
3"SAN
3"SAN
2"SAN
3"SAN
2"SAN
2"SAN
3"SAN
TP-2
TP-2
3" VTR
P-103
P-202
P-408
P-103
P-103
P-408
WHA-1
3/4"CW
3/4"HW
1 1/2"CW
1 1/2"CW
1 1/2"CW
3/4"HWC
3/4"HW
1 1/2"CW
1 1/2"CW
WHA-1
3/4"CW
3/4"CW
1 1/2"CW
1 1/2"CW
3/4"HW
3/4"HWC
3/4"CW
REFER 7-B-PL-101
FOR CONTINUATION.
REFER 7-B-PL-101
FOR CONTINUATION.
TP-1
1/2"CW
TP-1
1/2"CW
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
ARCHITECTS Drawing Title Project Title
Location
Date Checked Drawn
Project Number
Building Number
Drawing Number
CONSULTANTS
Dwg: Of:
657-18-110CORRECT WORKPLACE & LIFE SAFETY
ISSUES, ABATE ASBESTOS, & IMPROVE
WAYFINDING
SEPTEMBER 12, 2018
Building Name
JOHN COCHRAN DIVISION -
Revisions: Date:
3705 North 200th Street Elkhorn, Nebraska 68022
(402) 291-6941
15 Sunnen Drive Suite 104 St. Louis, MO 64143
(314) 645-1132
8802 South 135th Street, Suite 100 Omaha, NE 68138
(402) 861-4445
BID DOCUMENTS
VETERANS
HEALTH
ADMINISTRATION
/1
/2
:4 :5
P
M
7-1-PL-101
FIRST FLOOR - PLUMBING RENOVATION PLAN
ST. LOUIS MO - JOHN COCHRAN
SCOPRZ
43 79
BUILDING 7
GORPAT/
MATKAH
N
O R HT
1/8" = 1'-0"1
FIRST FLOOR - PLUMBING RENOVATION PLAN
DEDUCT ALTERNATE
NO SCALE2
RISER DIAGRAM FOR SANITARY AND VENT
NO SCALE3
RISER DIAGRAM FOR DOMESTIC